Winegard Power Supply Rv 0751 Users Manual 2451487

RV-0751 to the manual 16befd92-9ef8-4ac9-b0c8-a56c3b244154

2015-02-03

: Winegard Winegard-Power-Supply-Rv-0751-Users-Manual-479774 winegard-power-supply-rv-0751-users-manual-479774 winegard pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

This unit is equipped with a polyswitch,
(current limiting device), which will shut down
+12VDC if there is a direct short between
antenna and power supply. Green indicator
light will not light. Once short is eliminated,
device will reset itself in approximately 2 minutes.
DESCRIPTION
Wall plate/power supply to operate Winegard
RV antenna with outdoor receptacle for TV set
and cable or satellite input. Wall plate/power
supply provides +12 VDC to antenna as well as
antenna signals to two TV sets. Cable input
from outdoor receptacle connects to wall plate
and may be switched so either antenna or cable
signals may be watched. See applications.
There is also an auxiliary jack for a third
signal.
NOTE: THIS UNIT IS NOT AN AMPLIFIER. USE ONLY
WITH A WINEGARD AMPLIFIED RV ANTENNA.
INSTRUCTIONS
WINEGARD COMPANY
3000 KIRKWOOD ST., BURLINGTON, IA 52601-2000
Printed in U.S.A. 2451487 REV2 1/10
STEP 4. Install connectors on downlead and
set 2 cable as shown in Figure 5. Attach
downlead cable to jack on wall plate/power
supply marked antenna as shown in Figure 4.
Attach cable going to set 2 outlet to jack on
power supply marked SET 2. Attach cable
coming from cable input to jack on power
supply marked CABLE.
OPERATION: To receive cable signals from
outdoor receptacle: Press switch to (OFF)
position. Light on wallplate will go (OFF)
showing that power is no longer connected to
the antenna and the TV sets are receiving
signals from outdoor receptacle. To receive
signals from antenna: Press switch to (ON)
position. Light on wall plate will come (ON)
showing that power is connected to the antenna
and theTV sets are receiving signals from the
antenna. NOTE: Make sure TV antenna is in
the (UP) position and pointed at the station
RV WALL PLATE/
POWER SUPPLY
MODEL RV-0751 (almond bulk)
MODEL RV-0752 (white bulk)
MODEL RV-7542 (white single)
Made in U.S.A.
INSTALLING FC-5910
CONNECTORS ON COAX CABLE
1/2" *
¼" *
Center Conductor
Inner Insulation
Outer Cover
Crimp Here
1.
2.
3.
STEP 1: Strip outer cover back 1/2"* from end of cable. Fray braid
back as far as outer cover will allow.
STEP 2: Trim braid close to outer cover and remove 1/4"* of inner
insulation being careful not to nick center conductor. Make
sure no foil or braid can touch center conductor.
STEP 3: Slide connector tip between braid and inner insulation
(braid and foil, on foil shield cable) and push connector on cable as
far as it will go. Crimp built-in ferrule with proper crimping tool. Hex
connector requires hex crimping tool. Do Not crush cable out-
of-round.
* If installing in very hot weather, increase dimensions 1/8".
STEP 5. Mount power supply in wall with
screws provided and attach TV set cable to jack
on front. Connect band separator to VHF and
UHF antenna terminals of TV set, if required.
Press switch on front of outlet and check that
light is on.
Figure 4
Figure 5
desired. To receive satellite signal, attach
coax from receiver/antenna to Auxiliary jack
on wall plate.
Antenna Cable
Auxiliary
(Satellite Receiver)
Set 2
WINEGARD MOBILE PRODUCTS LIMITED WARRANTY
(2 YEARS PARTS; 1 YEAR LABOR)
Winegard Company warrants this product against defects in
materials or workmanship for a period of two (2) years from the date
of original purchase. During year one (1) of such warranty, Winegard
Company will also pay authorized labor costs to an authorized
Winegard dealer to repair or replace defective products. No warranty
claim will be honored unless at the time the claim is made, Customer
presents proof of purchase to an authorized Winegard dealer (to
locate the nearest authorized Winegard dealer, contact Winegard
Company, 3000 Kirkwood Street, Burlington, Iowa 52601,
Telephone 800-288-8094 or visit www.winegard.com). Customer
must provide proof of purchase with a dated sales receipt for the
Winegard product to verify the product is under warranty. If the date
of purchase cannot be verified, the warranty period shall be
considered to begin thirty (30) days after the date of manufacture.
If a defect in material or workmanship is discovered, Customer
may take the product to an authorized Winegard dealer for service.
Customer must provide proof of purchase to verify the product is
under warranty. If the product is brought to an authorized Winegard
dealer for service prior to expiration of year one (1) of the warranty
period and a defect in material or workmanship is verified by
Winegard Technical Services, Winegard Company will cover the
Winegard dealer’s labor charges for warranty service. The Winegard
dealer must contact Winegard Technical Services in advance for
pre-approval of the service. Approval of the service is at the sole
discretion of Winegard Company.
Alternatively, Customer may ship the product prepaid to Winegard
Technical Services (located at 3111 Kirkwood Street, Burlington,
Iowa 52601, Telephone 800-788-4417). Customer must return the
product along with a brief description of the problem and provide
Winegard Technical Services with Customer’s name, address,
and phone number. Customer must also provide proof of purchase
to verify the product is under warranty. If the product is returned
before the expiration of the warranty period, Winegard Company
will (at its option) either repair or replace the product.
This Limited Warranty does not apply if the product has been
damaged, deteriorates, malfunctions or fails from: improper
installation, misuse, abuse, neglect, accident, tampering,
modification of the product as originally manufactured by Winegard
in any manner whatsoever, removing or defacing any serial number,
usage not in accordance with product instructions or acts of nature
such as damage caused by wind, lightning, ice or corrosive
environments such as salt spray and acid rain. This Limited Warranty
also does not apply if the product becomes unable to perform its’
intended function in any way as a result of the television signal
provider making any changes in technology or service.
RETURN AUTHORIZATION POLICY
A Return Material Authorization (RMA) is required prior to returning
any product to Winegard Company or Winegard Warranty Services
under this warranty policy. Please call our Technical Services
Department at 800-788-4417 or send an e-mail to
warranty@winegard.com to obtain the RMA number. Please furnish
the date of purchase when requesting an RMA number. Enclose
the product in a prepaid package and write the RMA number in
large, clear letters on the outside of the package. To avoid confusion
or misunderstanding, a shipment(s) without an RMA number(s) or
an unauthorized return(s) will be refused and returned to Customer
freight collect.
WINEGARD COMPANY DOES NOT ASSUME ANY LIABILITIES
FOR ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, MADE
BY ANY OTHER PERSON.
ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED
OR STATUTORY INCLUDING WARRANTIES OF FITNESS FOR
A PARTICULAR PURPOSE AND MERCHANTABILITY ARE
LIMITED TO THE TWO YEAR PERIOD OF THIS WARRANTY.
In states that do not allow limitations on implied warranties, or
the exclusion of limitation of incidental or consequential damages,
the above limitations or exclusions do not apply.
Some states do not allow limitations on how long an implied
warranty lasts, or the exclusion of limitation of incidental or
consequential damages, so the above limitations or exclusions
may not apply to you.
This warranty gives Customer specific legal rights. Customer
may also have other rights that may vary from state to state.
SATELLITE RECEIVER WARRANTY:
See manufacturers limited warranty policy.
WS-MOBWARREV2 Rev. 1/10
Example 3
WARNING: Use of this on/off
power switch with any product
other than Winegard amplified
RV antenna, could result in fire
or other damage.
INSTRUCTIONS
APPLICATIONS AND
ALTERNATE CONNECTIONS
STEP 1. Select location for wall plate and
patio receptacle if required. Run coax cables
between locations and install connectors on
each end. Mark cables so they may be
identified. Antenna downlead and +12 VDC
will also be needed at inside wall plate/power
supply location.
STEP 2. The wall plate assembly may be
flush mounted in most standard electrical boxes.
To flush mount, cut a hole in wall to fit the box.
Route all cables to the wall plate and other
outlets required at this time. The Auxiliary
jack is designed for the use of satellite
receivers, etc. requiring direct line input.
WHEN CONNECTING CABLE OR WIRES
BE SURE SWITCH IS IN OFF POSITION.
STEP 3. Make +12 VDC connection by
running two #12 wires between the wall plate
and +12 VDC source. Install terminals on wires
from +12 VDC source as shown in Figure 1.
Crimp terminals with Craftsman type 4 crimping
tool or equivalent. Push wires onto tabs on
terminal board as shown in Figure 2. If in doubt
as to the polarity of the wires, connect them
temporarily to tabs on circuit board and press
switch on front of outlet. If light comes on,
polarity is correct. See Figure 3.
Figure 2
Figure 3
Auxilliary
Antenna Outdoor Receptacle
WA-1010
TV
Outlet
Antenna
Input
Cable Input
Cable Input
Set 1
Example 1
Antenna Outdoor Receptacle
WA-1010
TV
Outlet
Antenna
Input
TG-7221
Cable
Input
Set 2
Set 1
SP-1002
Splitter
Example 2
Antenna
Antenna
Input
TG-7221
Cable
Input
Set 2
Set 1
ON/OFF
Switch
ON/OFF
Switch
ON/OFF
Switch
Outdoor Receptacle
WA-1010
Figure 1
Connector
Insulation
Remove 1/4" of
insulation from
#12 wire.
#12 Wire
1/4"
Connector
Ferrule
Crimp Here
+12 VDC
Ground
Set 1
Set 2

Navigation menu