4iiii Innovations PM100 Precision User Manual
4iiii Innovations Inc. Precision User Manual
Contents
- 1. user manual
- 2. User-Manual
User-Manual
Quick Start Guide ® What’s in the Box? Head Office 228 River Avenue Cochrane, AB Canada T4C 2C1 Your PrecisionTM power meter comes with the following items: +1 403.800.3095 www.4iiii.com Technical support available from 4iiii by email from 9am-5pm Mountain Time. Email: support@4iiii.com © Copyright by 4iiii Innovations Inc. All rights reserved. Text, text excerpts, images and diagrams are all subject to copyright. No part may be reproduced or copied without written permission from the publisher. • 1 PrecisionTM power meter pod with installed battery • 1 PrecisionTM installation tool • 1 PrecisionTM installation band • 1 Epoxy adhesive pack • 1 Epoxy adhesive applicator • 1 Square of sand paper (1.5” x 1.5”) • 2 Cleaning wipes • 1 Cable tie • 1 Extra CR2032 coin cell battery Important Product Information FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This product does not contain any user-serviceable parts. Repairs, changes or modifications of this product, not expressly approved by the manufacturer will void the user’s authority to operate the equipment under FCC regulations. IC Compliance This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Installation Tools In addition to the contents included with your power meter, you will also need the following: • Crank removal tool • Pencil or permanent marker • Clean piece of printer paper Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Declaration of Conformity 4iiii Innovations Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. To view the full Declaration of Conformity, go to www.4iiii.com/compliance. Warnings 1. Limited Warranty This product does not contain any user-serviceable parts. For more information, go to www.4iiii. com/legal-policies. WARNING! DO NOT INSTALL THIS PRECISION POWER METER ON A CARBON FIBER CRANK ARM. DOING SO WILL VOID THE WARRANTY. 2. 3. 4. Do not remove the protective tape on the metal plate of the pod until you are ready to apply the epoxy adhesive – removing the tape prematurely will result in contamination of the pod and may interfere with the accuracy and reliability of the power meter Once the protective tape on the metal plate of the pod has been removed, do not touch the metal plate or place the metal plate on any surfaces – will result in contamination of the pod and may interfere with the accuracy and reliability of the power meter Once the protective tape of the pod has been removed, do not place the protective tape or any other material back on the metal plate – only the provided epoxy adhesive should be placed on the metal plate Do not put any other tape on the metal plate on the pod or the crank arm, doing so will contaminate the surfaces and impact the accuracy of the power meter 5. Do not open the adhesive pack until you are ready to apply the adhesive for installation – do not use the adhesive if it has been opened for more than 5 minutes 6. Only use supplied cleaning wipes for your installation – do not sand or use any other cleaning agents on the pod 7. Only apply epoxy adhesive directly to the metal base of the pod – do not put adhesive on your crank arm 8. Do not attempt to clean off the excess epoxy with any solvents – doing so may damage your power meter 9. Only perform the pod installation in temperatures above 20°C or 68°F – doing so will not allow the adhesive to cure properly and will impact the accuracy of the power meter 10. Do not expose the pod to temperatures above 50°C or 122°F 11. Do not install the pod on uneven or curved surfaces on the crank arm 12. Do not install this power meter pod on carbon fiber crank arms 1.2 Clearance Check Make sure there is enough room between the crank arm and the bicycle frame to install the PrecisionTM power meter pod. A minimum of 2 mm or 3/32 inch of space is present between the PrecisionTM pod and the bike frame >2 mm >3/32 in 1. Compatibility Check 1.1 Crank arm compatibility Ensure that the crank arm has a flat surface for installing the PrecisionTM power meter pod. Figure 1.2 Figure 1.1 Visit www.4iiii.com/precision to see the crank arm compatibility list and make sure your crank arm is listed as being compatible with the PrecisionTM. The compatibility list is frequently updated. Do not remove the protective tape on the metal plate at the bottom of the pod – doing so may interfere with the accuracy and reliability of the power meter. To avoid contamination of the metal plate, clean your crank arm with soap and water prior to performing the clearance check. Once the crank arm has been thoroughly cleaned, dry the area with a lint-free cloth or shop rag. 1.2.1 Pod Placement 1.2.3 Clearance Check Locate a flat area on the inner face of the crank arm for installing the PrecisionTM power meter pod. There should be a minimum of 40 mm or 1 5/8 inches between the pod location and the pedal spindle. With the PrecisionTM pod fixed onto the crank arm as shown in section 1.2.2, slowly and carefully rotate the crank arm 1 full revolution to ensure there is no interference between the pod and any part of the bicycle frame. Do not place the pod over uneven surfaces, decals, stickers, rivets, or screw holes on the crank arm. Doing so will interfere with the accuracy of the power meter. 1.2.2 Using Installation Tool and Installation Band Place and hold the metal plate of the PrecisionTM pod on the crank arm as shown in section 1.2.1 and secure the pod on the crank arm using the provided installation tool and installation band. Pull the installation band around the crank arm and attach them to the hooks on the pod. Figure 1.3 Figure 1.4 Slide the installation tool under the band and fix the pod in place with the installation tool. Figure 1.6 If the pod interferes with the frame or any other components on the bicycle, do not proceed further with the installation. Contact your retailer for assistance. If your pod was purchased directly from 4iiii Innovations, contact 4iiii online at www.4iiii.com/support/ software-and-documentation. Figure 1.5 1.2.4 Marking Install Location 2.2.2 Clean Crank Arm With the PrecisionTM pod fixed onto the crank arm as shown in section 1.2.2, place a small mark on your crank using a pencil or permanent marker adjacent to the center mark on the pod. This is use to mark the location of the pod for installation using the provided epoxy adhesive. Thoroughly clean the crank arm with soap and water to remove all dust and residue from sanding. Allow the crank arm to fully dry before adhering the pod. Do not attempt to dry the crank arm with paper towel or a cloth that may leave lint or other particles on your crank. To reduce drying time, you may use a lint free shop towel to dry the crank surface. 2.3 Adhering the Pod Figure 1.7 2. Pod Installation 2.1 Install Location Prior to installing the PrecisionTM power meter on your crank arm, ensure the pod has the necessary clearance for the bicycle as shown in igure 1.2, in section 1. Once a suitable location for the pod has been found, mark the install location as shown in section 1.2.4. 2.2 Preparing Crank Surface Before the PrecisionTM pod can be adhered to the crank arm, the crank arm surface must be sanded and thoroughly cleaned. Do not open or mix the adhesive pack until you are ready to apply the adhesive for installation – do not use the adhesive if it has been opened for more than 5 minutes. nd Do not open or mix the adhesive pack until you are ready to apply the adhesive for installation – do not use the adhesive if it has been opened and/or mixed for more than 5 minutes. Only perform the pod installation in temperatures above 20°C or 68°F – doing so will not allow the adhesive to cure properly and will impact the performance and reliability of the power meter. 2.3.1 Prepare Adhesive Tear open the two epoxy adhesive packets squeeze the adhesive onto a clean piece of printer paper. Mix the adhesive thoroughly with the adhesive applicator. wis th Sa Before adhering the pod, ensure the following items are readily accessible: • PrecisionTM pod • PrecisionTM install band • PrecisionTM install tool • Cleaning wipes (2x) • Epoxy adhesive packs • Adhesive applicator • Clean printer paper len Figure 2.1 2.3.2 Wipe Crank Arm Open one of the cleaning wipes and wipe the installation location of the crank arm. Slide the installation tool under the band and fix the pod in place with the installation tool. Only use supplied cleaning wipes for your installation – do not sand or use any other cleaning agents on the pod. Figure 2.4 2.3.3 Remove Protective Tape Remove the protective tape on the metal plate of the pod. Figure 2.5 Figure 2.2 2.3.4 Apply Adhesive Using the adhesive applicator, spread the mixed epoxy adhesive onto the metal plate of the pod. Ensure the entire metal plate has a uniform layer of adhesive material. Figure 2.6 Do not attempt to clean off the excess epoxy with any solvents – doing so may damage your power meter. 2.3.6 Curing Adhesive Figure 2.3 Only apply epoxy adhesive directly to the metal base of the pod – do not put adhesive on your crank arm. Set the crank arm aside with the pod facing down for 8 hours in a warm location at room temperature and allow the adhesive to cure. Do not allow the pod to cure in temperatures below 20°C or 68°F – doing so will not allow the adhesive to cure properly and will impact the accuracy of the power meter. Do not expose the pod to temperatures above 50°C or 122°F. 2.3.5 Fix Pod on Crank Arm Place and hold the PrecisionTM pod on the install location as marked on the crank arm in section 1.2.1 and secure the pod on the crank arm using the provided installation tool and installation band. Pull the installation band around the crank arm and attach them to the hooks on the pod. 10 11 4iiii Innovation Inc. Model: PM100 Appendix I How to install the battery of the precisionTM power meter PM100 1. Turn the back cover of the product anti-clockwise to unlock it and take it off. 2. Remove the used battery and install new battery. 3. Fix the back cover to the product. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital devi ce, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protect ion against harmful interference in a residential installation. This equipment generates and c an radiate radio frequency energy and, if not installed and used in accordance with the instr uctions, may cause harmful interference to radio communications. However, there is no gua rantee that interference will not occur in a particular installation. If this equipment does cau se harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one o r more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of FCC Rules. Operation is subject to the following two con ditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause un desired operation. Note: The manufacturer is not responsible for any radio or TV interference caused by unauth orized modifications to this equipment. Such modifications could void the user’s authority to operate this equipment. FCC RF Radiation Exposure Statement The device has been evaluated to meet general RF exposure requirement. The devic e can be used in portable exposure condition without restriction. IC Compliance This device complies with Industry Canada license‐exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Declaration of Conformity 4iiii Innovations Inc. declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. To view the full Declaration of Conformity, go to www.4iiii.com/compliance. Limited Warranty This product does not contain any user‐serviceable parts. For more information, go to www.4iiii.com/legal‐policies.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Create Date : 2014:12:30 08:02:16-07:00 Metadata Date : 2015:05:06 23:14:50+08:00 Modify Date : 2015:05:06 23:14:50+08:00 Creator Tool : Adobe InDesign CC 2014 (Macintosh) Instance ID : uuid:241414a8-c02f-4f5e-b033-204a1d2774ca Original Document ID : xmp.did:3596aa9a-1dd0-40e8-aa50-92f7f2793f1d Document ID : xmp.id:788cfd9f-9078-45fd-a178-4f96dde91e49 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4bca3e6e-5626-4498-9ff1-eb53d1bda9c4 Derived From Document ID : xmp.did:4bca3e6e-5626-4498-9ff1-eb53d1bda9c4 Derived From Original Document ID: xmp.did:3596aa9a-1dd0-40e8-aa50-92f7f2793f1d Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Macintosh) History Changed : / History When : 2014:12:30 08:02:16-07:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 9 Creator : Adobe InDesign CC 2014 (Macintosh)EXIF Metadata provided by EXIF.tools