4iiii Innovations PM100 Precision User Manual

4iiii Innovations Inc. Precision

Contents

user manual

Download: 4iiii Innovations PM100 Precision User Manual
Mirror Download [FCC.gov]4iiii Innovations PM100 Precision User Manual
Document ID2608392
Application IDVkAMB778QTlhL5eXjPiN6A==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize39.03kB (487918 bits)
Date Submitted2015-05-09 00:00:00
Date Available2015-11-05 00:00:00
Creation Date2014-12-30 08:02:16
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2015-05-06 23:14:50
Document Titleuser manual
Document CreatorAdobe InDesign CC 2014 (Macintosh)

Quick Start Guide
®
What’s in the Box?
Head Office
228 River Avenue
Cochrane, AB
Canada T4C 2C1
Your PrecisionTM power meter comes with the following
items:
+1 403.800.3095
www.4iiii.com
Technical support available from 4iiii by email from 9am-5pm Mountain
Time.
Email: support@4iiii.com
© Copyright by 4iiii Innovations Inc.
All rights reserved. Text, text excerpts, images and diagrams are all subject
to copyright. No part may be reproduced or copied without written
permission from the publisher.
• 1 PrecisionTM power meter pod with installed battery
• 1 PrecisionTM installation tool
• 1 PrecisionTM installation band
• 1 Epoxy adhesive pack
• 1 Epoxy adhesive applicator
• 1 Square of sand paper (1.5” x 1.5”)
• 2 Cleaning wipes
• 1 Cable tie
• 1 Extra CR2032 coin cell battery
Important Product Information
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation. This product
does not contain any user-serviceable parts. Repairs, changes or modifications of this product, not
expressly approved by the manufacturer will void the user’s authority to operate the equipment
under FCC regulations.
IC Compliance
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Installation Tools
In addition to the contents included with your power meter,
you will also need the following:
• Crank removal tool
• Pencil or permanent marker
• Clean piece of printer paper
Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas
produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Declaration of Conformity
4iiii Innovations Inc. declares that this product is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC. To view the full Declaration of Conformity, go to
www.4iiii.com/compliance.
Warnings
1.
Limited Warranty
This product does not contain any user-serviceable parts. For more information, go to www.4iiii.
com/legal-policies.
WARNING!
DO NOT INSTALL THIS
PRECISION POWER METER
ON A CARBON FIBER
CRANK ARM.
DOING SO WILL VOID THE
WARRANTY.
2.
3.
4.
Do not remove the protective tape on the metal plate
of the pod until you are ready to apply the epoxy
adhesive – removing the tape prematurely will result
in contamination of the pod and may interfere with
the accuracy and reliability of the power meter
Once the protective tape on the metal plate of the
pod has been removed, do not touch the metal plate
or place the metal plate on any surfaces – will result in
contamination of the pod and may interfere with the
accuracy and reliability of the power meter
Once the protective tape of the pod has been
removed, do not place the protective tape or any other
material back on the metal plate – only the provided
epoxy adhesive should be placed on the metal plate
Do not put any other tape on the metal plate on the
pod or the crank arm, doing so will contaminate the
surfaces and impact the accuracy of the power meter
5.
Do not open the adhesive pack until you are ready to
apply the adhesive for installation – do not use the adhesive if it has been opened for more than 5 minutes
6. Only use supplied cleaning wipes for your installation
– do not sand or use any other cleaning agents on the
pod
7. Only apply epoxy adhesive directly to the metal base of
the pod – do not put adhesive on your crank arm
8. Do not attempt to clean off the excess epoxy with any
solvents – doing so may damage your power meter
9. Only perform the pod installation in temperatures
above 20°C or 68°F – doing so will not allow the adhesive to cure properly and will impact the accuracy of the
power meter
10. Do not expose the pod to temperatures above 50°C or
122°F
11. Do not install the pod on uneven or curved surfaces on
the crank arm
12. Do not install this power meter pod on carbon fiber
crank arms
1.2 Clearance Check
Make sure there is enough room between the crank arm
and the bicycle frame to install the PrecisionTM power meter
pod. A minimum of 2 mm or 3/32 inch of space is present
between the PrecisionTM pod and the bike frame
>2 mm
>3/32 in
1. Compatibility Check
1.1 Crank arm compatibility
Ensure that the crank arm has a flat surface for installing the
PrecisionTM power meter pod.
Figure 1.2
Figure 1.1
Visit www.4iiii.com/precision to see the crank
arm compatibility list and make sure your crank
arm is listed as being compatible with the
PrecisionTM. The compatibility list is frequently
updated.
Do not remove the protective tape on the
metal plate at the bottom of the pod – doing
so may interfere with the accuracy and
reliability of the power meter.
To avoid contamination of the metal plate,
clean your crank arm with soap and water
prior to performing the clearance check. Once
the crank arm has been thoroughly cleaned,
dry the area with a lint-free cloth or shop rag.
1.2.1 Pod Placement
1.2.3 Clearance Check
Locate a flat area on the inner face of the crank arm for
installing the PrecisionTM power meter pod. There should
be a minimum of 40 mm or 1 5/8 inches between the pod
location and the pedal spindle.
With the PrecisionTM pod fixed onto the crank arm as shown
in section 1.2.2, slowly and carefully rotate the crank arm 1
full revolution to ensure there is no interference between the
pod and any part of the bicycle frame.
Do not place the pod over uneven surfaces,
decals, stickers, rivets, or screw holes on the
crank arm. Doing so will interfere with the
accuracy of the power meter.
1.2.2 Using Installation Tool and Installation Band
Place and hold the metal plate of the PrecisionTM pod on
the crank arm as shown in section 1.2.1 and secure the pod
on the crank arm using the provided installation tool and
installation band.
Pull the installation band around the crank arm and attach
them to the hooks on the pod.
Figure 1.3
Figure 1.4
Slide the installation tool under the band and fix the pod in
place with the installation tool.
Figure 1.6
If the pod interferes with the frame or any
other components on the bicycle, do not
proceed further with the installation. Contact
your retailer for assistance. If your pod was
purchased directly from 4iiii Innovations,
contact 4iiii online at www.4iiii.com/support/
software-and-documentation.
Figure 1.5
1.2.4 Marking Install Location
2.2.2 Clean Crank Arm
With the PrecisionTM pod fixed onto the crank arm as shown
in section 1.2.2, place a small mark on your crank using a
pencil or permanent marker adjacent to the center mark
on the pod. This is use to mark the location of the pod for
installation using the provided epoxy adhesive.
Thoroughly clean the crank arm with soap and water to
remove all dust and residue from sanding. Allow the crank
arm to fully dry before adhering the pod.
Do not attempt to dry the crank arm with
paper towel or a cloth that may leave lint
or other particles on your crank. To reduce
drying time, you may use a lint free shop
towel to dry the crank surface.
2.3 Adhering the Pod
Figure 1.7
2. Pod Installation
2.1 Install Location
Prior to installing the PrecisionTM power meter on your crank
arm, ensure the pod has the necessary clearance for the
bicycle as shown in igure 1.2, in section 1. Once a suitable location for the pod has been found, mark the install location
as shown in section 1.2.4.
2.2 Preparing Crank Surface
Before the PrecisionTM pod can be adhered to the crank
arm, the crank arm surface must be sanded and thoroughly
cleaned.
Do not open or mix the adhesive pack until
you are ready to apply the adhesive for installation – do not use the adhesive if it has
been opened for more than 5 minutes.
nd
Do not open or mix the adhesive pack until you
are ready to apply the adhesive for installation
– do not use the adhesive if it has been opened
and/or mixed for more than 5 minutes.
Only perform the pod installation in temperatures above 20°C or 68°F – doing so will not
allow the adhesive to cure properly and will
impact the performance and reliability of the
power meter.
2.3.1 Prepare Adhesive
Tear open the two epoxy adhesive packets squeeze the adhesive onto a clean piece of printer paper. Mix the adhesive
thoroughly with the adhesive applicator.
wis
th
Sa
Before adhering the pod, ensure the following items are
readily accessible:
• PrecisionTM pod
• PrecisionTM install band
• PrecisionTM install tool
• Cleaning wipes (2x)
• Epoxy adhesive packs
• Adhesive applicator
• Clean printer paper
len
Figure 2.1
2.3.2 Wipe Crank Arm
Open one of the cleaning wipes and wipe the installation
location of the crank arm.
Slide the installation tool under the band and fix the pod in
place with the installation tool.
Only use supplied cleaning wipes for your installation – do not sand or use any other cleaning
agents on the pod.
Figure 2.4
2.3.3 Remove Protective Tape
Remove the protective tape on the metal plate of the pod.
Figure 2.5
Figure 2.2
2.3.4 Apply Adhesive
Using the adhesive applicator, spread the mixed epoxy adhesive onto the metal plate of the pod. Ensure the entire metal
plate has a uniform layer of adhesive material.
Figure 2.6
Do not attempt to clean off the excess epoxy
with any solvents – doing so may damage
your power meter.
2.3.6 Curing Adhesive
Figure 2.3
Only apply epoxy adhesive directly to the metal
base of the pod – do not put adhesive on your
crank arm.
Set the crank arm aside with the pod facing down for 8
hours in a warm location at room temperature and allow the
adhesive to cure.
Do not allow the pod to cure in temperatures below 20°C or 68°F – doing so will not
allow the adhesive to cure properly and will
impact the accuracy of the power meter.
Do not expose the pod to temperatures
above 50°C or 122°F.
2.3.5 Fix Pod on Crank Arm
Place and hold the PrecisionTM pod on the install location as
marked on the crank arm in section 1.2.1 and secure the pod
on the crank arm using the provided installation tool and
installation band.
Pull the installation band around the crank arm and attach
them to the hooks on the pod.
10
11
4iiii Innovation Inc.
Model: PM100
Appendix I
How to install the battery of the precisionTM power meter PM100
1. Turn the back cover of the product anti-clockwise to unlock it and take it off.
2. Remove the used battery and install new battery.
3. Fix the back cover to the product.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital devi
ce, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protect
ion against harmful interference in a residential installation. This equipment generates and c
an radiate radio frequency energy and, if not installed and used in accordance with the instr
uctions, may cause harmful interference to radio communications. However, there is no gua
rantee that interference will not occur in a particular installation. If this equipment does cau
se harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one o
r more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of FCC Rules. Operation is subject to the following two con
ditions: (1) This device may not cause harmful interference, and (2)
This device must accept any interference received, including interference that may cause un
desired operation.
Note: The manufacturer is not responsible for any radio or TV interference caused by unauth
orized modifications to this equipment. Such modifications could void the user’s authority to
operate this equipment.
FCC RF Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement. The devic
e can be used in portable exposure condition without restriction.
IC Compliance
This device complies with Industry Canada license‐exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil
ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
Declaration of Conformity
4iiii Innovations Inc. declares that this product is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC. To view the full
Declaration of Conformity, go to www.4iiii.com/compliance.
Limited Warranty
This product does not contain any user‐serviceable parts. For more information, go to
www.4iiii.com/legal‐policies.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Create Date                     : 2014:12:30 08:02:16-07:00
Metadata Date                   : 2015:05:06 23:14:50+08:00
Modify Date                     : 2015:05:06 23:14:50+08:00
Creator Tool                    : Adobe InDesign CC 2014 (Macintosh)
Instance ID                     : uuid:241414a8-c02f-4f5e-b033-204a1d2774ca
Original Document ID            : xmp.did:3596aa9a-1dd0-40e8-aa50-92f7f2793f1d
Document ID                     : xmp.id:788cfd9f-9078-45fd-a178-4f96dde91e49
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:4bca3e6e-5626-4498-9ff1-eb53d1bda9c4
Derived From Document ID        : xmp.did:4bca3e6e-5626-4498-9ff1-eb53d1bda9c4
Derived From Original Document ID: xmp.did:3596aa9a-1dd0-40e8-aa50-92f7f2793f1d
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Macintosh)
History Changed                 : /
History When                    : 2014:12:30 08:02:16-07:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 9
Creator                         : Adobe InDesign CC 2014 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZZNPM100

Navigation menu