ADC Telecommunications FWURHHOST FlexWave™ URH Host User Manual 75348p1

ADC Telecommunications Inc FlexWave™ URH Host 75348p1

Contents

User manual 1

Download: ADC Telecommunications FWURHHOST FlexWave™ URH Host User Manual 75348p1
Mirror Download [FCC.gov]ADC Telecommunications FWURHHOST FlexWave™ URH Host User Manual 75348p1
Document ID1005346
Application IDZDCsj6FmsAiDCteJ2InalA==
Document DescriptionUser manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize272.13kB (3401614 bits)
Date Submitted2008-09-23 00:00:00
Date Available2008-09-24 00:00:00
Creation Date2008-09-05 08:37:31
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-09-05 08:37:59
Document Title75348p1.book
Document CreatorFrameMaker 7.2
Document Author: eisfeld

™
ADC FlexWave Universal
Radio Head (URH) Host Unit
Installation Instructions
ADCP-75-348 • Issue 1 • 04/2008
22408-A
1427955 Rev A
ADCP-75-348 • Issue 1 • 04/2008 • Preface
COPYRIGHT
© 2008, ADC Telecommunications, Inc.
All Rights Reserved
REVISION HISTORY
ISSUE
DATE
04/2008
REASON FOR CHANGE
Original
TRADEMARK INFORMATION
ADC is a registered trademark of ADC Telecommunications, Inc., FlexWave is a trademark of ADC Telecommunications, Inc.
DISCLAIMER OF LIABILITY
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no
event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further
disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of
liability applies to all products, publications and services during and after the warranty period.
This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 73475
(in U.S.A. or Canada) or 952-917-3475 (outside U.S.A. and Canada), or by e-mail to connectivity_tac@adc.com.
ADC Telecommunications, Inc.
P.O. Box 1101, Minneapolis, Minnesota 55440-1101
In U.S.A. and Canada: 1-800-366-3891
Outside U.S.A. and Canada: (952) 938-8080
Fax: (952) 917-1717
Page ii
ADCP-75-348 • Issue 1 • 04/2008 • Preface
TABLE OF CONTENTS
Content
Page
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Admonishments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
STANDARDS CERTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
List of Acronyms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOST UNIT DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2
SeRF Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.3
3.2.1
Network Interface Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2.2
Craft Interface Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.2.3
Optical Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DART Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.3.1
RF Signal Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4
System Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.5
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.6
User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
HOST UNIT ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1
Wavelength Division Multiplexer System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.1
Before Starting Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6.2
Unpacking and Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.3
OSP Fiber Cable Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.4
WDM Host Module Mounting Shelf and WDM Host Module Installation Procedure . . . . . . . . . . . . . . . . . . . . 12
6.5
HU Mounting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.6
Chassis Ground Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.7
Coaxial Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.8
Optical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6.1.1
6.9
Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.8.1
Optical Connections Without WDM System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.8.2
Optical Connections For Systems With a WDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
EXT REF Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.10 Computer Connection (CRAFT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.11 Network Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.12 System Alarm System Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.13 Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.13.1 DC Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.14 Installation Complete. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Page iii
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008 • Preface
TABLE OF CONTENTS
Content
Page
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
7.1
Host Unit Fan Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7.2
Power Supply Replacement Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
7.3
System Card Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
7.4
SeRF Card Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
7.5
DART Card Replacement/Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7.5.1
Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7.5.2
Install New DART Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
CUSTOMER INFORMATION AND ASSISTANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Page iv
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008 • Preface
ABOUT THIS MANUAL
This manual describes how to install and cable a URH Host chassis within a non-condensing
indoor environment such as inside a wiring closet or an outdoor controlled environment cabinet.
RELATED PUBLICATIONS
Listed below are related manuals, their content, and their publication numbers. Copies of these
publications can be ordered by contacting the Technical Assistance Center at 1-800-366-3891,
extension 73476 (in U.S.A. or Canada) or 952-917-3476 (outside U.S.A. and Canada). All ADC
technical publications are available for downloading from the ADC web site at www.adc.com.
Title/Description
ADCP Number
ADC FlexWave™ Universal Radio Head (URH) Remote Installation Instructions
ADC FlexWave™ Universal Radio Head (URH) System User Manual
ADC FlexWave™ Universal Radio Head (URH) System EMS User Manual
ADC FlexWave™ URH Remote Unit Mounting Kit Installation Instructions
78-347
75-349
75-350
75-351
ADMONISHMENTS
Important safety admonishments are used throughout this manual to warn of possible hazards to
persons or equipment. An admonishment identifies a possible hazard and then explains what
may happen if the hazard is not avoided. The admonishments — in the form of Dangers,
Warnings, and Cautions — must be followed at all times.
These warnings are flagged by use of the triangular alert icon (seen below), and are listed in
descending order of severity of injury or damage and likelihood of occurrence.
Danger: Danger is used to indicate the presence of a hazard that will cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Warning: Warning is used to indicate the presence of a hazard that can cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Caution: Caution is used to indicate the presence of a hazard that will or can cause minor
personal injury or property damage if the hazard is not avoided.
GENERAL SAFETY PRECAUTIONS
Warning: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrically-powered equipment. To prevent electrical shock, never install or
use electrical equipment in a wet location or during a lightning storm.
Page v
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008 • Preface
Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation
can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not
look directly into the optical transceiver of any digital unit or exposure to laser radiation may
result. An optical power meter should be used to verify active fibers. A protective cap or hood
MUST be immediately placed over any radiating transceiver or optical fiber connector to avoid
the potential of dangerous amounts of radiation exposure. This practice also prevents dirt
particles from entering the adapter or connector.
Caution: This system is a RF Transmitter and continuously emits RF energy. Maintain 3 foot
(91.4 cm) minimum clearance from the antenna while the system is operating. Wherever
possible, shut down the RAN before servicing the antenna.
Caution: Always allow sufficient fiber length to permit routing of patch cords and pigtails
without severe bends. Fiber optic patch cords or pigtails may be permanently damaged if bent
or curved to a radius of less than 2 inches (5.1 cm).
Caution: Exterior surfaces of the RU may be hot. Use caution during servicing.
STANDARDS CERTIFICATION
FCC: This equipment complies with the applicable sections of Title 47 CFR Part 15 (Host
unit), Part 22 (800 MHz Cellular), Part 24 (1900 MHz - PCS), and Part 90 (800/900 - SMR).
IC: This equipment complies with the applicable sections of RSS-131. The term “IC:” before the
radio certification number only signifies that Industry Canada Technical Specifications were met.
The Manufacturer's rated output power of this equipment is for single carrier operation. For
situations when multiple carrier signals are present, the rating would have to be reduced by 3.5
dB, especially where the output signal is re-radiated and can cause interference to adjacent band
users. This power reduction is to be by means of input power or gain reduction and not by an
attenuator at the output of the device.
Caution: Modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum
composite output form the antenna cannot exceed 1000 Watts ERP (Cellular and SMR), the
antenna cannot exceed 1640 Watts EIRP (PCS), and the antenna must be permanently installed
in a fixed location that provides at least 6 meters (20 feet) of separation from all persons.
UL/CUL: This will be installed in a restricted access location. This equipment complies with
NEMA Type 6, per UL and CUL 50, Standard for Enclosures for Electrical Equipment. This
equipment provides the degree of protection specified by IP67 as defined in IEC Publication 529.
Conforms to ANSI/UL Std. 60950. Certified to CAN/CSA STD C22.2 No 60950
UL/CUL: This Host equipment complies with UL and CUL 60950 Standard for Safety for
Information Technology Equipment, including Electrical Business Equipment.
FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules. This
product conforms to all applicable standards of 21 CFR Part 1040.
Page vi
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008 • Preface
LIST OF ACRONYMS AND ABBREVIATIONS
The acronyms and abbreviations used in this manual are detailed in the following list:
AC
BTS
CM
CPU
DART
DAS
dB
dBc
dB(FS)
dBm
DC
Div
EMS
ESD
FCC
GPS
GUI
HU
IC
IF
IP
LED
LNA
LPA
LSE
LVD
MUX
OSP
PA
PC
PCI
QMA
RAN
RDI
RF
Alternating Current
Base Transceiver Station
Centigrade
Centimeter
Central Processing Unit
Digital/Analog Radio Transceiver (DART board)
Distributed Antenna System
decibel
The ratio (in dB) of the sideband power of a “signal” measured in a given bandwidth at a given frequency offset from the center frequency of the same signal,
to the total inband power of the signal.
decibals (Full Scale – digital reading)
deciBels relative to 1mW
Direct Current
Diversity
Element Management System
Electrostatic Discharge
Fahrenheit
Federal Communications Commission
Global Positioning System
Graphical User Interface
Host Unit
Industry Canada
Intermediate Frequency
Internet Protocol
Light Emitting Diode
Low Noise Amplifier
Linear Power Amplifier
Location Services Equipment
Low Voltage Disconnect
Multiplexer
Outside Plant
Power Amplifier
Personal Computer
Peripheral Component Interconnect bus
Quick disconnect version of Sub Miniature version A
Radio Access Node
Remote DART Interface (RDI board)
Radio Frequency
Page vii
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008 • Preface
RU
SeRF
SFP
SMA
UL
VAC
VDC
VSWR
WDM
WSP
Remote Unit
Serialized RF (SeRF board)
Small Form-Factor Pluggable Optical Transceiver
Subminiature version A; Small form factor coaxial connector
Underwriters Laboratories
Volts Alternating Current
Volts Direct Current
Voltage Standing Wave Ratio
Wave Division Multiplex
Wireless Service Provider
Page viii
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
GENERAL
The FlexWave URH product family of products is intended as a “next generation” distributed
antenna system (DAS). DAS products provide bidirectional transport of digitized RF spectrum.
Each link consists of a host unit (providing the interface between the base station RF ports and the
optical fiber) and at least one remote unit (providing the interface between the optical fiber and the
remote antenna). The difference in this product is the high-speed digitalization of a wideband
portion of spectrum, that allows for transport of RF signals over extended distances, without the
RF degradation that normally results when analog systems are impacted by optical effects.
The basic function of the FlexWave URH platform is to transport via fiber optic cable RF
signals form a Base Transceiver Station (BTS) to an antenna interface allowing communication
to a mobile device. Multiple BTS communication paths are allowed over a single URH system.
Diversity receive is supported. A block diagram of the system is shown in Figure 1.
BTS 1
FWD RF IN
FWD RF OUT
REV RF OUT
REV RF IN
FWD RF IN
BTS 2
BTS 3
REV RF OUT
Flexwave
URH
HOST
Flexwave
URH
REMOTE
FWD RF OUT
REV RF IN
FWD RF IN
FWD RF OUT
REV RF OUT
REV RF IN
ANTENNA
INTERFACE
BTS 1
ANTENNA
INTERFACE
BTS 2
ANTENNA
INTERFACE
BTS 3
NON-DIVERSITY
BTS 1
FWD RF IN
FWD RF OUT
REV RF OUT
REV RF IN
REV DIV RF OUT
REV DIV RF IN
FWD RF OUT
FWD RF IN
BTS 2
BTS 3
REV RF OUT
REV DIV RF OUT
ANTENNA
INTERFACE
BTS 1
Flexwave
URH
HOST
Flexwave
URH
REMOTE
REV RF IN
REV DIV RF IN
FWD RF IN
FWD RF OUT
REV RF OUT
REV RF IN
REV DIV RF OUT
REV DIV RF IN
DIVERSITY
ANTENNA
INTERFACE
BTS 2
ANTENNA
INTERFACE
BTS 3
22380-A
Figure 1. FlexWave URH Block Diagram
The basic function of the FlexWave URH simulcast (point-to-point) platform is to transport, via
fiber optic cable, RF signals form a Base Transceiver Station (BTS) to multiple antenna interfaces
allowing communication to a mobile device. Up to 8 simulcast remotes are supported.
Page 1
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
INTRODUCTION
The front access URH Host Unit interfaces with the BTS and performs the analog to digital and
electrical to optical conversions for transport to the URH Remote Units. A typical URH system
consists of a Host Unit (HU) and a Remote Unit (RU).
The HU is designed for maximum RF flexibility to address Carriers changing and evolving
spectrum needs, making the most use of cost efficient resources for serving multiple remotes
such as simulcast architecture and sharing of common functions such as power, control and
management over multiple host units. These features are designed into a compact package that
reduces the amount of overall rack space required within a BTS Hotel. Each host chassis can
support up to eight RUs.
The HU is a three rack-unit high single-unit assembly that mounts in a standard equipment rack.
The RU consists of an outdoor enclosure that houses various electronic components. The RU is
a modular self-contained enclosure. Together the HU and the RU together comprise an URH
system. Various accessory items are also available for use with each system. All items
referenced as “accessory items” are not furnished and must be purchased separately.
HOST UNIT DESCRIPTION
A front view of the HU, shown in Figure 2, consists of an electronic circuit board assembly and a
fan assembly that are mounted within a powder-paint coated sheet metal enclosure. The enclosure
provides a mounting point for the circuit board and fan assembly and controls RF emissions. Fan
assembly can be replaced in the field. Host Unit may be upgraded once it is installed to support
additional URH Remote Units. This can be performed without disrupting service.
REV
RF OUT
REV
RF OUT
REV
RF OUT
REV
RF OUT
STATUS
PWR
STATUS
PWR
STATUS
PWR
STATUS
PWR
REV
RF IN
REV
RF OUT
REV
RF IN
REV
RF OUT
REV
RF IN
REV
RF OUT
REV
RF IN
REV
RF OUT
STATUS
PWR
STATUS
PWR
STATUS
PWR
STATUS
PWR
REV
RF IN
REV
RF IN
REV
RF IN
REV
RF IN
22381-A
Figure 2. Front View Host Unit
The HU is designed for use within a non-condensing indoor environment such as inside a wiring
closet or controlled environment cabinet. All controls, connectors, and indicators (except the
grounding point) are mounted on the HU front panel. Current versions of the HU allow vertical
cable guides to be installed over the mounting brackets on either side of the HU.
Page 2
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
3.1
Mounting
The HU is intended for rack-mount applications. A pair of reversible mounting brackets is
provided that allow the HU to be mounted in either a 19-inch or 23-inch EIA or WECO
equipment rack. When installed, the front panel of the HU is flush with the front of the rack.
Screws are provided for securing the HU to the equipment rack.
3.2
SeRF Card
3.2.1
Network Interface Connection
SeRF front panel has an Ethernet port allowing interface communication with the internal
processor and transfer of data to the optical protocol allowing IP transport between the HU and
the remote(s). The network interface allows the HU to be controlled through a network.
Network interface connection between the HU and the network is supported by a RJ-45 jack 10/
100Base-T (IEEE802.3 compliant) with integrated green ACTIVITY and LINK LEDs. The
Ethernet port supports a maximum cable length of 100 meters (328 feet) to a hub or back-toback nodes. CAT5 or better cable should be used when making this connection. The Ethernet
connection should not be connected to an Ethernet circuit used outside the building.
1. The IEEE Specification for Ethernet 100BaseT requires that two twisted pairs be used and that
one pair is connected to pins 1 and 2, and that the second pair is connected to pins 3 and 6.
2. Pinout information is shown in Table 1. See Figure 3 for RJ45 connector wiring
information.
Table 1. 100BaseT Ethernet RJ45 Connector
PIN #
DESCRIPTION
TRD0+
TRD0–
TRD1+
TRD2+
TRD2–
TRD1–
TRD3–
TRD3+
Page 3
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
PIN 1
PIN 8
RJ-JACK
11899-A
Figure 3. RJ45 Connector Wiring
3.2.2
Craft Interface Connection
SeRF front panel provides a craft port that can be used to provision remote units through the
optical protocol supported by a single RJ-45 connector. The Craft connector provides an
Ethernet interface.
Craft interface connection between the HU and the network is supported by a RJ-45 jack 10/
100Base-T (IEEE802.3 compliant) with integrated green ACTIVITY and LINK LEDs. The
Ethernet port supports a maximum cable length of 100 meters (328 feet) to a hub or back-toback nodes. CAT5 or better cable should be used when making this connection.
1. The IEEE Specification for Ethernet 100BaseT requires that two twisted pairs be used and that
one pair is connected to pins 1 and 2, and that the second pair is connected to pins 3 and 6.
2. Pinout information is shown in Table 1. See Figure 3 for RJ45 connector wiring
information.
3.2.3
Optical Interface
Optical connections between the HU SeRF card and the RU are supported through Small Formfactor Pluggable (SFP) transceivers. The optical interfaces are standard single-mode duplex LC
(flat polished UPC). There are 8 duplex optical interfaces, one for each simulcast remote.
3.3
DART Card
The host DART provides the interface between base station equipment and the SeRF. It is a
band specific assembly and exists in the following versions:
• Cellular
• SMR 800
• SMR 900
• PCS
The following features and capabilities are available on the DART Card:
• Amplifies, down-converts, filters and digitizes from a 1.5MHz to 35MHz band of the
incoming RF signal
Page 4
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
• Converts incoming digital signal to analog, filters, amplifies and up-converts
• Provides bi-directional interface between parallel digital RF (to D/A and from A/D) and
Serial RF (SeRF) to/from SeRF board
• Performs digital up/down conversion and adjustable delay processing
• Non-contiguous bands and receive diversity is implemented with multiple DART Cards
3.3.1
RF Signal Connections
The RF signal connections between the HU DART cards and the BTS are supported through
two (FWD RF IN and REV RF OUT) QMA-Type female connectors. One connector is used for
the forward path RF signal. The other connector is used for the reverse path RF signal. In some
installations, it may be necessary to install a Conditioning Panel and/or Duplexing Panel
(accessory items) to support the interface between the HU and the BTS. The HU should be as
close as possible to the BTS to minimize cable losses.
3.4
System Card
The System Interface Card gives additional front panel space for the SeRF card. The System
Card front panel also provides connections for alarm outputs, 10 MHz output, and status LEDs.
This card may be used to provide a 10 MHz clock reference to which the SeRF's Master clock is
frequency locked from the internal crystal oscillator. When the internal clock is not used the
clock can be obtained from an external 10 MHz input.
3.5
Power Supply
HU is powered by a modular DC to DC power supply located on the lower left side of the
chassis. An On/Off switch is provided on the HU power supply module front panel.
HU is powered by ± 20 to ± 60 VDC power (nominal ± 24 or ± 48 VDC), power is fed to the HU
through a connector located on the front of the module. Power to the HU must be supplied
through a fuse panel (available separately). Each HU must be protected with a fuse.
3.6
User Interface
The HU user interface consists of the various connectors, switches, terminals, and LEDs that are
provided on the HU front panel. The HU user interface points are indicated in Figure 4 and
described in Table 2.
Page 5
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
(5) NETWORK (13) REF LED
INTERFACE INDICATORS
(6) CRAFT
INTERFACE
(3) PORT 2
REV
CONNECTOR
(2) PORT 1
FWD
CONNECTOR
(1) SeRF CARD
ALARM LEDS
(4) OPTICAL PORT
CONNECTORS 3 - 8
22382-B
(10) SYSTEM CARD
POWER LED
INDICATOR
(11) HOST
(14 & 15)
ALARM
REF OUT
AND IN JACKS OUTPUTS
(8) DC POWER
ON/OFF SWITCH
(9) POWER
CONNECTOR
(7) POWER
LED INDICATOR
(12) REMOTE
ALARM
OUTPUTS
(18) REV RF
OUT JACK
(19) FWD RF
IN JACK
(17) DART STATUS
LED INDICATOR
(16) DART POWER
LED INDICATOR
Figure 4. Host Unit User Interface
Table 2. Host Unit User Interface
REF
NO
USER INTERFACE
DESIGNATION
DEVICE
FUNCTIONAL DESCRIPTION
SeRF CARD
SeRF Card LEDs
ALARM
GREEN
RED
No alarms
Alarms present
SYNTH
GREEN
RED
Locked
Unlocked
SW FLT
GREEN
RED
Software operating OK
Software fault present
PWR
GREEN
OFF
Power OK and operating properly
No power present
PORT 1 or FWD
LC connector
(single-mode)
Output connection point for the forward path
optical fiber.
PORT 2 or REV
LC connector
(single-mode)
Input connection point for the reverse path primary optical fiber.
PORT 3 –8
LC connector
(single-mode)
Input/output connection points for the remaining
optical fibers.
NETWORK
RJ-45 jack (female)
Connection point for the NETWORK interface
input cable.
CRAFT
RJ-45 jack (female)
Connection point for the CRAFT interface input
cable.
Page 6
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
Table 2. Host Unit User Interface, continued
REF
NO
USER INTERFACE
DESIGNATION
DEVICE
FUNCTIONAL DESCRIPTION
POWER SUPPLY
PWR (LED)
GREEN
RED
DC Power Supply OK
DC Power Supply Fault
ON/OFF
On/Off rocker switch Provides HU power on/off control.
POWER 20–60 VDC
Three position
connector
Connection point for the DC power wiring.
SYSTEM CARD
10
PWR (LED)
GREEN
RED
System Card Power Supply OK
System Card Power Supply Fault
11
ALARM OUTPUTS
HOST
12
ALARM OUTPUTS
REMOTE
Twelve position terminal block. Screwtype terminal
connector (14–26
AWG)
Connection points for an major and minor dry
alarm contacts. Includes normally open (NO),
normally closed (NC), and common (COM) wiring connections.
13
INT REF (LED)
GREEN
EXT REF (LED)
OFF
GREEN
OFF
Internal 10 MHz reference selected as the as Reference Clock.
Internal 10 MHz reference not selected.
External 10 MHz reference selected as the as
Reference Clock.
External 10 MHz reference not selected
14
REF OUT
QMA-Type female
Ref Clock
RF coaxial connector
15
EXT REF IN
QMA-Type female
Ref Clock
RF coaxial connector
DART CARD
16
PWR (LED)
GREEN
OFF
Card is powered.
No power present at card.
17
STATUS (LED)
GREEN
RED
YELLOW
OK
Fault
Unlocked
18
REV RF OUT
QMA-Type female
Output connection point for the primary reverse
RF coaxial connector path RF coaxial cable.
19
FWD RF IN
QMA-Type female
Input connection point for the forward path RF
RF coaxial connector coaxial cable.
HOST UNIT ACCESSORIES
This section provides a brief description of various accessory items that are available separately.
The accessory items may or may not be required depending on the application.
Page 7
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
4.1
Wavelength Division Multiplexer System
The Wavelength Division Multiplexer (WDM) system is an accessory product that is used when
it is desirable or necessary to combine the forward and reverse path optical signals from one
URH system onto a single optical fiber. Each WDM system consists of a host module and a
remote module.
Both the host unit WDM module and the RU WDM module consist of a bi-directional wavelength
division multiplexer. The host unit WDM module is mounted within a powder-paint coated sheet
metal enclosure. A straight LC-type optical connector port is provided for connecting the forward/
reverse path optical fiber to the WDM module. A pair of pigtail leads with LC-type connectors are
provided for connecting the WDM module to the forward and reverse path optical ports on the HU
SeRF card.
The WDM host module mounting shelf and host module are shown in Figure 5. The WDM
module is shown in Figure 6.
22390-A
Figure 5. WDM Host Module and Host Module Mounting Shelf
22391-A
Figure 6. Host Unit WDM Module
Page 8
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
SPECIFICATIONS
The specifications for the host unit are provided in Table 3.
Table 3. Host Unit Nominal Specifications
PARAMETER
SPECIFICATION
REMARKS
Dimensions (H×W×D)
5.17 × 17.26 × 9.5 inches
(131.3 × 438.4 × 241.3 mm)
Dimension for width does not
include the mounting brackets
which can be installed for either
19- or 23-inch racks.
Mounting
19- or 23-inch rack
EIA or WECO
Weight
20 lbs. (9.1 kg)
Weather resistance
Indoor installation only
Operating temperature
0º to 55º C (32º to 131º F)
Storage temperature
–40º to 70º C (–40º to 158ºF)
Humidity
10% to 90%
No condensation
Optical ports
SFP pluggable transceivers
LC (UPC)
Transceivers
Fujitsu FIM32151 or FIM32141
Available from ADC
External alarm connector
Screw-type terminals
NO, COM, and NC relay contacts
Environmentally controlled outdoor cabinet.
Voltage input
DC Power
±20 – ±60 VDC
Power consumption
320 Watts (Maximum)
202 Watts nominal
Current rating
4.2 Amps
7.2 Amps
At –48VDC
At +28VDC
RF coaxial cable connectors
50 ohm QMA – type (female)
50 ohms input/output impedance
Network and Craft connectors
RJ–45 jack
Reliability at 25ºC
MTBF 100,000 hours
Including fans
INSTALLATION
This section provides the installation procedures for the HU and the WDM host module
(accessory item). Installation of the RU components may proceed separately from installation of
the HU.
6.1
Before Starting Installation
Before beginning the installation, review the system design plan with the system engineer.
Make sure each equipment installation site is identified and located and all cable runs are
mapped out. Also identify all tools and materials that are required to complete the installation.
Page 9
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
6.1.1
Tools and Materials
The following tools are required to complete the procedures in this section:
•
•
•
•
•
•
•
•
•
•
Box cutter
Pencil or scribe
Medium size flat-bladed screwdriver
Phillips screwdriver (#2)
Pliers
Wire cutters
Wire stripper
Tool kit for attaching QMA-Type male connectors to coaxial cable
Multimeter
Optical power meter
The following materials are required to complete the procedures in this section:
•
•
•
•
•
•
•
•
•
•
6.2
#18 AWG (1.0 mm) insulated stranded copper wire (for chassis grounding wire)
#18 AWG (1.0 mm) red and black insulated copper wire (for DC power wires)
Category 3 or 5 cable (for external alarm system wires)
Category 5 cable with RJ45 connectors for the Network and Craft port
#6 ring terminal (1) for #18 wire (for chassis ground wire connection)
#6 fork terminals (2) for #18 wire (for DC power wiring connection)
Single-mode patch cord(s) with LC connectors (1 – 8 depending on the application)
High performance, flexible, low-loss 50-ohm coaxial cable
QMA-type male connectors
Wire ties
Unpacking and Inspection
This section provides instructions for opening the shipping boxes, verifying that all parts have
been received, and verifying that no shipping damage has occurred. Use the following
procedure to unpack and inspect the HU and any accessories:
Unpack and inspect the various components as follows:
1. Inspect the exterior of the shipping container(s) for evidence of rough handling that may
have damaged the components in the container.
2. Unpack each container while carefully checking the contents for damage and verify with
the packing slip.
3. If damage is found or parts are missing, file a claim with the commercial carrier and notify
ADC Customer Service. Save the damaged cartons for inspection by the carrier.
4. Refer to Section 8 if you need to contact ADC.
5. Save all shipping containers for use if the equipment requires shipment at a future date.
Page 10
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
6.3
OSP Fiber Cable Installation Guidelines
The outside plant (OSP) fiber optic cables should be routed between the HU distribution panel
and RU outside plant cabinet and terminated before the equipment is installed. A diagram of a
typical OSP cable routing is shown in Figure 7. At the HU, the OSP cable should be terminated
at a fiber distribution panel and spliced to pigtails. Jumper patch cords may then be used to link
the HU optical ports to the OSP cable terminations. Whenever possible, a guideway such as the
FiberGuide system should be provided to protect the fiber optic patch cords from damage and to
prevent excessive bending. The procedures for connecting the OSP cable optical fibers to the
HU is provided in Section 6.8.
SPLICE
HOST UNIT
TERMINATION
HOST SITE
PATCH
CORDS
FIBER DISTRIBUTION
PANEL
OUTSIDE PLANT
CABLE
OUTDOOR
REMOTE SITE
INDOOR
REMOTE SITE
URH
REMOTE
UNIT
URH
REMOTE
UNIT
INDOOR/OUTDOOR
QUAD CABLE WITH
PRE-TERMINATED
CONNECTOR
22383-A
OUTSIDE PLANT
CABINET
Figure 7. Typical Fiber Optic Cable Routing
Page 11
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
6.4
WDM Host Module Mounting Shelf and WDM Host Module Installation Procedure
A bi-directional wavelength division multiplexer (WDM) system is available as an accessory
item for the URH system. If the application does not require the use of a WDM system, skip this
section and proceed to Section 6.5.
The WDM host module mounting shelf installs in the equipment rack with the HU. Each host
module mounting shelf can hold multiple modules and each host module can support two HU’s.
When multiple HU’s require connection to a WDM system, the host module mounting shelf and
the HU’s should be mounted in the equipment rack as shown in Figure 8. This configuration
allows the pigtail leads from the two host modules to be connected directly to the optical ports
on any one of the four HU’s.
POWERWORX
FUSE PANEL
WDM MOUNTING
SHELF
(WITHOUT MODULES)
HOST SLACK FIBER STORAGE
HOST UNITS
22392-A
Figure 8. Typical WDM and HU Configuration
The WDM host module mounting shelf may be mounted in either a 19-inch or 23-inch EIA or
WECO equipment rack. Four #12-24 screws are provided for securing the mounting shelf to the
rack. Use the following procedure to install the WDM host module mounting shelf in the
equipment rack and to mount the WDM modules in the WDM host module mounting shelf:
Page 12
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
1. The WDM host module mounting shelf is shipped with the mounting brackets installed for
23-inch rack installations. If installing the mounting shelf in a 23-inch rack, proceed to
Step 4. If installing the mounting shelf in a 19-inch rack proceed to Step 2.
2. Remove both mounting brackets from the mounting shelf (requires Phillips screwdriver)
and save screws for reuse.
3. Reinstall both mounting brackets so the short side of the bracket is flush with the front
panel as shown in as shown in Figure 9. Use the screws removed in Step 2 to attach the
new brackets to the mounting shelf.
22393-A
Figure 9. Installing the Replacement Mounting Brackets
4. Position the mounting shelf in the designated mounting space in the rack (per system
design plan) and then secure the mounting brackets to the rack using the four #12-24
machine screws provided.
5. Install each WDM host module in the mounting shelf. A rail on the side of the module fits
into a guide within the mounting.
6. Secure each host module to the mounting shelf by twisting the handle on each quarter-turn
fastener 90º.
7. Carefully store the pigtail leads from each host module. The routing and connection
procedures for the pigtails are provided in Section 6.8.
6.5
HU Mounting Procedure
The HU may be mounted in either a 19-inch or 23-inch EIA or WECO equipment rack. Both
US standard and metric machine screws are included for rack mounting the HU. When loading
the HU in a rack, make sure the mechanical loading of the rack is even to avoid a hazardous
condition such as a severely unbalanced rack. The rack should safely support the combined
weight of all the equipment it holds. In addition, maximum recommended ambient temperature
for the HU is 55º C (131º F). Allow sufficient air circulation or space between units when the
HU is installed in a multi-rack assembly because the operating ambient temperature of the rack
environment might be greater than room ambient.
Page 13
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
Warning: Wet conditions increase the potential for receiving an electrical shock when
installing or using electrically powered equipment. To prevent electrical shock, never install or
use electrical equipment in a wet location or during a lightning storm.
Note: To insure that all optical connectors remain dust-free during installation, leave all dust
caps and dust protectors in place until directed to remove them for connection.
Use the following procedure to install the HU in the equipment rack:
1. The HU is shipped with the mounting brackets installed for 19-inch rack installations. If
mounting the HU in a 19-inch rack, proceed to Step 4. If mounting the HU in a 23-inch
rack, proceed to Step 2.
2. Remove both mounting brackets from the HU (requires TORX screwdriver with T20 bit)
and save screws (six-screws on each side) for reuse.
3. Reinstall both mounting brackets so the short side of the bracket is flush with the HU front
panel as shown in Figure 10. Use the screws removed in Step 2 to re-attach the brackets to
the HU chassis.
INSTALL MOUNTING
BRACKETS AS SHOWN FOR
INSTALLATION IN 23-INCH RACKS
22394-A
Figure 10. Installing the Mounting Brackets for 23-Inch Rack Installations
4. Position the HU in the designated mounting space in the rack (per system design plan) and
then secure (but do not tighten) the HU to the rack using the four machine screws provided
(use #12-24 or M6 x 10 screws, whichever is appropriate).
Note: Provide a minimum of 3 inches (76 mm) of clearance space on both the left and
right sides of the HU for air intake and exhaust.
5. Locate two vertical cable guides, not provided with the HU.
Note: A vertical cable guide kit is available separately as an accessory.
Page 14
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
6. Back out the HU mounting screws just enough to provide clearance for installation of the
cable guides.
7. Slide each cable guide into position for installation and then securely tighten the
corresponding mounting screws.
6.6
Chassis Ground Connection
A stud is provided on the rear side of the chassis for connecting a grounding wire to the chassis.
Use the following procedure to connect the grounding wire to the chassis and to route the
grounding wire to an approved earth ground source.
1. Obtain a length of #18 AWG (1.00 mm) insulated stranded copper wire for use as a
chassis grounding wire.
2. Terminate one end of the wire with a ring terminal.
3. Locate the chassis ground stud at the rear of the HU as shown in Figure 11.
4. Attach the ring end of the wire to the chassis ground stud (see Figure 11).
STAR
WASHER
HEX
NUT
REAR OF
CHASSIS
22395-A
GROUND
WIRE
Figure 11. Chassis Ground Stud
5. Route the free end of the chassis grounding wire to an approved (per local code or
practice) earth ground source.
6. Cut the chassis grounding wire to length and connect it to the approved ground source as
required by local code or practice.
Note: Be sure to maintain reliable grounding. Pay particular attention to ground source
connections.
Page 15
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
6.7
Coaxial Cable Connections
The RF interface between the HU DART card and the EBTS/BTS is supported through two type
QMA female connectors mounted on each DART front panel. One connector provides the
coaxial cable connection for the forward path (downlink) signal and the other connector
provides the coaxial cable connection for the reverse path (uplink) signal.
In most installations, it is usually necessary to insert an external attenuator into the forward path
link between the HU and the BTS. A signal level that is greater than –9 dBm will overdrive and
possibly damage the HU receiver. Before completing the forward path connection at the BTS,
verify that the composite forward path RF signal level at the HU is between –25 and +5 dBm.
The HU should be mounted as close as possible to the EBTS/BTS to minimize cable losses. Use
the following procedure to route and connect the forward and reverse path coaxial cables to the
HU DART cards:
1. Obtain the required lengths of high performance, flexible, low loss 50-ohm coaxial
communications cable (RG-400 or equivalent) for all coaxial connections.
2. Route the forward and reverse path coaxial cables between the HU and the BTS interface
(per system design plan) and cut to the required length. Allow sufficient slack for dressing
and organizing cables at the HU and for installing an external attenuator in the forward
path link.
3. Terminate each cable with an QMA-Type male connector following the connector
supplier’s recommendations.
4. If required, install an external attenuator in the forward path.
Note: The composite forward path RF signal level at the HU must be between –25 and
+5 dBm. Do not connect the forward path cable until the composite forward path RF
signal level is measured and the amount of external attenuation required is determined.
5. Connect the forward path cable to the FWD RF IN connector on the HU DART front
panel as shown in Figure 12.
6. Connect the reverse path cable to the REV RF OUT connector on the HU DART front
panel (see Figure 12).
7. Repeat this procedure for the remaining DART cards in the HU.
8. Dress and secure cables at the right side of the HU.
9. Complete all remaining coaxial connections as specified in the system design plan.
Page 16
© 2008, ADC Telecommunications, Inc.
ADCP-75-348 • Issue 1 • 04/2008
22411-A
Figure 12. Forward and Reverse Path Coaxial Cable Connections
6.8
Optical Connections
The optical interface between the HU and the RU is supported by optical ports. Each optical
port consists of an SFP with LC optical transceivers mounted on the SeRF card front panel.
Each FWD port provides an optical connection for the forward path (downlink) signal. Each
REV port provide an optical connection for the reverse path (uplink) signal. Each REV port can
also provide the optical connection for the diversity reverse path (uplink) signal.
The optical connections are dependent on whether or not a WDM host module (accessory) is
installed:
• If the installation does not include a WDM module, proceed to Section 6.8.1 for the
optical connections procedure.
• If the installation includes a WDM module, proceed to Section 6.8.2 for the optical
connections procedure.
Page 17
© 2008, ADC Telecommunications, Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-702
Modify Date                     : 2008:09:05 08:37:59-05:00
Create Date                     : 2008:09:05 08:37:31-05:00
Metadata Date                   : 2008:09:05 08:37:59-05:00
Creator Tool                    : FrameMaker 7.2
Format                          : application/pdf
Title                           : 75348p1.book
Creator                         : eisfeld
Document ID                     : uuid:77f4fd31-8dbd-4ea9-b021-cb4a0925cde3
Instance ID                     : uuid:1b9974d5-3f1f-48d9-a59e-9d753d490fb2
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Page Count                      : 25
Author                          : eisfeld
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F8I-FWURHHOST

Navigation menu