ADC Telecommunications PRSM070A FlexWave Prism - 700 Lower ABC - Band User Manual 1

ADC Telecommunications Inc FlexWave Prism - 700 Lower ABC - Band 1

User manual 1

Download: ADC Telecommunications PRSM070A FlexWave Prism - 700 Lower ABC - Band User Manual 1
Mirror Download [FCC.gov]ADC Telecommunications PRSM070A FlexWave Prism - 700 Lower ABC - Band User Manual 1
Document ID1379094
Application IDx9Fb9x3p4AY5zzrZeq37UQ==
Document DescriptionUser manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize26.18kB (327297 bits)
Date Submitted2010-11-19 00:00:00
Date Available2010-11-19 00:00:00
Creation Date2008-10-29 09:51:41
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2008-10-29 09:51:52
Document TitleUser manual 1
Document CreatorAdobe InDesign CS3 (5.0.4)

FlexWave™ Prism
Flexible Outdoor Wireless Coverage and Capacity
FlexWave™ Prism
Flexible Outdoor Wireless Coverage and Capacity
FlexWave™ – ADC’s Next Generation of Wireless Solutions
for Improving Wireless Capacity, Coverage, Flexibility
and Customer Retention
FlexWave™ Prism
ADC’s FlexWave™ Prism is the most flexible, scalable and complete solution for addressing coverage
and capacity needs for current and emerging wireless networks. The Prism improves wireless network
coverage and capacity by extending services from existing cell sites, to hard-to-reach areas by
distributing coverage from a centralized radio suite.
Utilizing a centralized distributed architecture, service providers are able to recognize significant
CAPEX/OPEX savings through a shared Base Station Hotel (multiple BTS co-located together), as well as
a shared Remote Radio Transceiver approach. The Prism’s flexibility and scalability offers service providers
an optimal solution for multiple applications such as; dense urban centers, dense suburban areas,
campuses, enterprise buildings, subways and tunnels. The Prism’s distributed architecture and small form
factor allows service providers to cost-effectively increase coverage and capacity in these hard-to-reach
areas.
Features and Benefits:
• Flexible Architecture
–– Supports multiple frequency bands and wireless protocols in one enclosure
–– Scalable and modular
–– Multiple non-contiguous segments of 1.5 to 75 MHz each
–– BTS interface supporting RF and OBSAI/CPRI standards (Future)
–– Field upgradeable
• User Friendly
–– Embedded element management system, supporting web based access and SNMP
–– Fully sealed, maintenance free electronics for harsh outdoor applications
• Cost Effective
–– Efficient use of CAPEX equipment and real estate
10/08
•
106969AE
–– Transport rates supporting Dark Fiber and Millimeter Wave
Overview
With the increasing popularity and reliance on wireless voice and data services, subscribers expect to
have coverage at anytime, anywhere. In addition to increased wireless device usage, wireless service
providers implementing 3G technologies have recognized a reduction in coverage patterns within
existing coverage footprints, opening coverage “holes” within the network. To resolve this issue, it
requires service providers to extend coverage and/or increase capacity within the non-coverage areas.
This has been traditionally accomplished by adding new macro cell towers; however, with city centers
becoming more congested and local government zoning regulations becoming more stringent,
obtaining permits for new macro cell sites is becoming increasingly difficult. The Prism offers service
providers a flexible, small form factor solution to extend coverage and capacity where needed, as well as
support for the increasing number of protocols and frequencies available today and in the future.
www.adc.com
•
+1-952-938-8080
•
1-800-366-3891
FlexWave™ Prism
Flexible Outdoor Wireless Coverage and Capacity
Application
The FlexWave Prism uses patented digital-over-fiber technology to distribute RF to desired locations. The
Prism digitizes the entire designated RF band and digitally transports it over dark fiber or millimeter wave
links and reconstructs the signal at full bandwidth, regardless of modulation technology, at the remote
location. ADC’s digital RF transport allows RF signals to be replicated at full dynamic range, independent of
the link length, for improved data throughput. As service providers migrate to 3G and 4G networks, highdata rate broadband services, networks utilizing a Prism backbone will be ready.
FlexWave™ Prism
The Prism offers a flexible architecture to distribute wireless coverage and capacity. Its versatility and small
form factor allow service providers to quickly deploy networks in areas where zoning restrictions often
hinder installation of traditional macro cell towers and base stations.
Centralization of base station capacity can also be realized using the FlexWave Prism. This allows service
providers to further benefit by reducing capital expenditures and annual operating costs.
System Description
The FlexWave Prism is a flexible and cost effective solution for Distributed Antenna System applications:
Microcell and/or CPRI/OBSAI Remote Radio Head applications:
• Next Generation DAS; optimized for multiple frequency bands, scalable RF bandwidth & transport rates
• Flexible SeRF technology; serial RF processing, enabling scalable frequency bands and bandwidths
• Digitial RF Transport; Digitally transports RF from the BTS to remote locations for distribution of RF signals.
• Digital simulcast; signal is digitally combined and split to mulitple remotes
Future enhancements will include:
• CPRI/OBSAI; flexibility to support BTS interface standards
• IP ready platform; smooth integration to IP front/backhaul networks
Sample System Configuration
(3 Band 3 Remote Simulcast)
REMOTES
•
106969AE
• Microcell; fully contained capacity solution utilizing cost efficient low bit-rate IP backhaul
HOST
10/08
OBSAI/CPRI
Multiplexed
SeRF over
mm-wave
SeRF
Base
Station 1
OBSAI/CPRI to
SeRF Converter
RF
SeRF
Base
Station 2
RF to SeRF
Converter
SeRF
Board
RF
SeRF
Base
Station 3
Multiplexed
SeRF over
Fiber
RF to SeRF
Converter
Data
Multiband,
protocol-agnostic
Universal Radio
Head
Backhaul
Multiplexed
SeRF over
mm-wave
www.adc.com
•
+1-952-938-8080
•
1-800-366-3891
FlexWave™ Prism
Flexible Outdoor Wireless Coverage and Capacity
Host Unit
The rack-mountable FlexWave Prism Host Unit is typically located at a Base Station or a facility housing
a suite of Base Stations. On the forward path, the Host Unit receives the RF signals from the BTS and
digitizes the designated RF bands and digitally transports them over single mode fiber or a millimeter
wave link to the Remote Units. On the reverse path, the Host Unit receives the digitized RF signals from
the Remote Unit and converts them back to RF for the BTS.
The Prism Host Unit is completely modular in design. Digital/Analog Radio Transceiver (DARTS) are hot
swappable providing easy upgrades to addtional bands without interrupting existing service.
The Prism Host Unit supports up to eight DART cards (supporting up to eight Remote Units) and
is capable of simulcasting signals up to as many as eight Remote Units.
106969AE
The Host Unit utilizes an embedded element management system for system configuration and network
monitoring. The embedded EMS collects alarm information from both the Host and Remote Units. For
multiple link deployments, multiple Host Units can be networked together at the same BTS site.
In addition to sending alarm notifications to the Element Management System (EMS) through software,
the Prism Host Unit also features front panel alarm reporting. LEDs on the front panel of the Host Unit
will change color depending on the status of the unit. LED displays provide information regarding the
following items:
•
FlexWave™ Prism
Host Unit
• RF conditions
• Power
• System mode (active/standby)
10/08
• Indicate unit fault condition
www.adc.com
•
+1-952-938-8080
•
1-800-366-3891
FlexWave™ Prism
10/08
•
106969AE
FlexWave™ Prism
Flexible Outdoor Wireless Coverage and Capacity
Single Band
Remote Unit
Dual Band
Remote Unit
Tri Band
Remote Unit
Quad Band
Remote Unit
Remote Units
The Prism Remote Units utilize a modular design, which supports up to four bands. Each Remote allows
for future upgrades and easy field access.
Typical mounting options for the Remote Unit include: pole-mount, inside pole-mount, wall-mount, and
sub-terrain vault-mount.
The electronics enclosure of the Prism Remote Unit is fully sealed IP-65 rated, which minimizes
maintenance and is ideal for harsh environments. Fiber, antenna, and power input/output connectors
are all sealed for maximum protection.
On the forward path, the Remote Unit receives the digitized spectrum from the Host Unit and converts
the spectrum back into RF to be distributed via an externally mounted antenna system. On the reverse
path, the Remote Unit digitizes the designated RF spectrum and digitally transports it over single-mode
fiber or MMW to the Host Unit.
In addition to sending alarm notifications to the EMS software, the Prism Remote Unit also features LED
alarm reporting. An LED on the bottom of the Remote Unit will illuminate upon a fault condition.
www.adc.com
•
+1-952-938-8080
•
1-800-366-3891
FlexWave™ Prism
Flexible Outdoor Wireless Coverage and Capacity
Alarm and Management System
The FlexWave Prism utilizes an embedded network management for system configuration and network
monitoring. The Element Management System (EMS) utilizes a web based interface or SNMP protocol
for easy accesses to the system.
10/08
•
106969AE
FlexWave™ Prism
The EMS provides operational and maintenance capabilities for the Prism system (Host and Remote). The
EMS can be used to set up and monitor status of any Host and any associated Remote Units. The EMS
has the ability to configure the system, view status and parameter settings, download software, change
parameters and monitor system performance and alarms
Access and troubleshooting can also be accomplished on-site at either the Host Unit and/or the Remote
Unit by utilizing a craft interface. Thus, allowing technicians the ability to plug-in a laptop and access all
associated units connected to it.
Host Site Capabilities
The EMS performs the following functions at the
Host site:
• Provides real-time information regarding faults
• Set up simulcast ratios
• Digital timing delays
• Displays various system level values (voltages,
RF, power, etc.)
• Records and generates history reports with
time and date stamps
• Adjusts performance related parameters of the
Host Unit and Remote Unit
• Permits placement of Host Unit and Remote
Unit into standby mode
• Allows download of new software versions to
the Host Unit and Remote Units
Network Monitoring Capabilities
The embedded EMS allows for remote alarm
monitoring and network control of the
Prism can also be performed from an off-site
location or Network Operation Center (NOC).
Communications to the NOC can be performed
using the web based interface or SNMP protocol.
The EMS performs the following functions at offsite locations such as the NOC:
• Provides real-time information regarding faults
• Displays various system level values (voltages, RF, power, etc.)
• Adjusts performance-related parameters of the Host Unit and Remote Unit
• Permits placement of Host Unit and Remote Unit into standby mode
• Access records and generates history reports with time and date stamps
• Allows download of new software versions to the Host Unit and Remote Units
www.adc.com
•
+1-952-938-8080
•
1-800-366-3891
FlexWave™ Prism
Flexible Outdoor Wireless Coverage and Capacity
10/08
•
106969AE
FlexWave™ Prism
Specifications
RF Specifications
Supported Frequency Blocks:
Bandwidth:
Frequency Band Supported:
Digital Simulcast:
Diversity Receive:
1-4 per Remote Unit; 1-8 per Host Unit
1.5 to 75 MHz non-contiguous
Cell (850), ESMR, PCS (1900), AWS (2100), E-GSM, DCS (1800), UMTS (2100)
Up to 8:1 Single Host (can daisy chain Host for higher simulcast)
Yes (Optional)
Propagation Delay
System Delay:
Delay Management:
<5 dB typical, 6 dB max
Digital (Manual or Automatic)
Noise Figure
	Noise Figure:
	Input IP3:
<5 dB typical, 6 dB max
>-8 dBm
Optical Specifications
	Optical Budget:
Digital Transport Rate:
26 dB
3.072 Gbps
Output PoweR at antenna port (dBm)
Number of RF Carriers
Frequency
Channels
Composite
Power per
Carrier
CELL (850)
43.0
ESMR
PCS (1900)
Composite
Power per
Carrier
43.0
43.0
38.1
38.1
43.0
43.0
AWS (2100)
43.0
E-GSM
Composite
Power per
Carrier
40.0
43.0
38.1
35.1
43.0
40.0
43.0
43.0
31.0
31.0
DCS (1800)
32.8
UMTS (2100)
42.5
16
Composite
Power per
Carrier
Composite
Power per
Carrier
37.0
43.0
34.0
43.0
31.0
32.1
32.1
38.1
29.1
38.1
26.1
43.0
37.0
43.0
34.0
43.0
31.0
40.0
43.0
37.0
43.0
34.0
–
–
34.0
31.0
37.0
31.0
40.0
31.0
40.0
28.0
32.8
35.8
32.8
38.1
32.8
41.8
32.8
41.8
29.8
42.5
42.5
39.5
42.5
36.5
42.5
33.5
–
–
REMOTE UNIT ENVIRONMENTAL Specifications
	Outside Ambient
Temp Rating:
-40°C to +50°C (-40ºF to +122ºF)
Storage Temperature:
-40°C to +70°C (-º40F to +158)
Humidity:
10% to 90% non-condensing
	Lightning Protection:
20kA IEC 1000-45 8/30 µs Waveform
Remote Unit
	Enclosure:
Mounting:
Single Band
		 Dimensions (H x W x D):
		 Volume:
		Weight:
Dual Band:
		 Dimensions (H x W x D):
		 Volume:
		Weight:
Tri Band:
		 Dimensions (H x W x D):
		 Volume:
		Weight:
Quad Band:
		 Dimensions (H x W x D):
		 Volume:
		Weight:
Cooling:
	Optical Connectors:
www.adc.com
•
IP-65
Wall, Pole, Inside Pole, Strand, and Vault
23.1” x 12.15” x 10.125” (58.67 cm x 30.86 cm x 25.71 cm)
1.56 ft3
47 lbs. chasis, 64 lbs. total (21 kg chasis, 29 kg total)
31.1” x 12.15” x 10.125” (78.99 cm x 30.86 cm x 25.71 cm)
2.10 ft3
63 lbs. chasis, 96 lbs. total (28 kg chasis, 43 kg total)
39.1” x 12.15” x 10.125” (99.31 cm x 30.86 cm x 25.71 cm)
2.64 ft3
79 lbs. chasis, 127 lbs. total (36 kg chasis, 57 kg total)
50.2” x 12.15” x 10.125” (127.51 cm x 30.86 cm x 25.71 cm)
3.40 ft3
98 lbs. chasis, 163 lbs. total (44 kg chasis, 74 kg total)
Fan, IP-55
Sealed Proax
+1-952-938-8080
•
1-800-366-3891
Specifications (con't)
Host Unit				
Mounting:
19-inch rack
Dimensions (H x W x D):
5.25" x 19" x 19" (13.34cm x 48.26 cm x 48.26) (3 RUs)
	Weight:
<25 Pounds (<11 kg)
Remote Unit Power Requirements
	Power Supply:
Battery Backup:
100-240 VAC, 50-60 Hz
Yes (optional external UPS)
Host Unit Power Requirements
	Power Source:
21 to 60 VDC
FlexWave™ prism
Element Management
	Embedded EMS:
Yes
SNMP Based Management:
Yes
Note: Unless noted otherwise specifications are typical and subject to change
Website: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
106969AE  10/08 Original
©
2008 ADC Telecommunications, Inc. All Rights Reserved

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.1-c037 46.282696, Mon Apr 02 2007 18:36:56
Create Date                     : 2008:10:29 09:51:41-05:00
Metadata Date                   : 2008:10:29 09:51:52-05:00
Modify Date                     : 2008:10:29 09:51:52-05:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9900 bytes, use -b option to extract)
Instance ID                     : uuid:3bc5fdc6-c053-4f74-8604-5467f9fb333d
Document ID                     : adobe:docid:indd:7a65aff8-80d5-11dd-92ef-fe9dddfea075
Rendition Class                 : proof:pdf
Derived From Instance ID        : acf07bcc-0169-11dd-9a6a-cc39889fc82f
Derived From Document ID        : adobe:docid:indd:482ed8cf-5450-11da-906a-b2083b848a1a
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:C5F37AF3A59811DD9615AF8B7BAFBD89, uuid:DE241FC7A5C611DD9407E459BF206171, uuid:28BC9A40A36411DD819FEDB5E67725F4, uuid:2848A419A68B11DD88EB9F2C87E3F74B, uuid:DDD4246D3A85DC1198DFF466938FB459, uuid:DBD4246D3A85DC1198DFF466938FB459
Manifest Reference Document ID  : uuid:C5F37AF2A59811DD9615AF8B7BAFBD89, uuid:59EC7CD3AE83DC11AB2B9CC09F37179E, uuid:28BC9A3FA36411DD819FEDB5E67725F4, uuid:0ECC8C64A36111DD819FEDB5E67725F4, uuid:DCD4246D3A85DC1198DFF466938FB459, uuid:DAD4246D3A85DC1198DFF466938FB459
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: F8I-PRSM070A

Navigation menu