ATEQ ATEQ-VTXX intelligent tire pressure Analyzer User Manual Meeting Review
ATEQ Corp. intelligent tire pressure Analyzer Meeting Review
ATEQ >
Manual
User’s manual TPM-RKE Analyzer 9936 Version 06.03 Daimler Chrysler Reference: QS-258DCA-U User guide REGULATORY STATEMENTS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions; (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. “Changes or modifications not expressly approved by the manufacture could void the user's authority to operate the equipment.” “NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. WARNING: Changes or modifications not expressly approved by the manufacturer may violate the user's authority to operate the equipment. Industries Canada: The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb" User’s Manual TABLE OF CONTENTS User guide TPM-RKE ANALYZER 9936............................................................................................. 2 .1 DESCRIPTION OF THE TPM-RKE ANALYZER 9936........................................................................ 2 .2 FEATURES.......................................................................................................................................... 3 ..1 Radio frequencies........................................................................................................................... 3 ..2 Type of valve.................................................................................................................................. 3 .3 CONNECTORS.................................................................................................................................... 4 ..1 Supply connector............................................................................................................................ 4 ..2 USB connector............................................................................................................................... 4 ..3 RS232 connector............................................................................................................................ 4 .4 DESCRIPTION OF THE INSTRUMENT............................................................................................... 5 ..1 Power on/off key............................................................................................................................. 5 .5 FRONT PANEL DESCRIPTION........................................................................................................... 6 ..1 Display............................................................................................................................................ 6 ..2 Lights.............................................................................................................................................. 6 ..3 Keys................................................................................................................................................ 6 .6 BATTERY SUPPLY............................................................................................................................. 7 ..1 Battery status.................................................................................................................................. 7 .7 MEASUREMENT.................................................................................................................................. 8 ..1 Key measurement (RKE test)......................................................................................................... 8 ..2 Valve measurement (TPM functions).............................................................................................. 9 .8 SETTINGS............................................................................................................................................ 12 ..1 Parameters menu........................................................................................................................... 12 .9 STARSCAN.......................................................................................................................................... 16 ..1 Data transfer................................................................................................................................... 16 ..2 TPM/RKE Analyzer program up-dating........................................................................................... 16 .10 MENU STRUCTURE.......................................................................................................................... 17 ..1 Main menu...................................................................................................................................... 17 .11 CORRESPONDANCES TABLES...................................................................................................... 19 ..1 Vehicle / Body / valve..................................................................................................................... 19 ..2 Countries / frequencies................................................................................................................... 19 ................................................................................................................................................................ 19 Index 20 User guide TPM-RKE Analyzer Page 1/20 User guide TPM-RKE ANALYZER 9936 .1 DESCRIPTION OF THE TPM-RKE ANALYZER 9936 The principal of this instrument is to awaken and then retrieve data from smart valves mounted on vehicle wheels in order to verify their identifiers. The instrument interacts with the smart valves without contact through wireless communication. LCD Display Light Indicators Keypad RS232 (RJ45) Connecter USB Connecter User guide TPM-RKE Analyzer Page 2/20 .2 FEATURES ..1 RADIO FREQUENCIES Awakening transmission frequency: 125 kHz (LF). Reception frequencies: 433 MHz or 315 MHz (RF). ..2 TYPE OF VALVE This instrument is especially designed for the measurement of the Siemens and Schrader valves installed into Daimler-Chrysler vehicles. Siemens Siemens Schrader User guide TPM-RKE Analyzer Page 3/20 .3 CONNECTORS ..1 SUPPLY CONNECTOR To supply the instrument and recharging the internal battery. The voltage of the charger is a 24 V DC. ..2 USB CONNECTOR The USB connector allows the instrument software programs to be updated. StarScan tool can retrieve information through the USB connector. ..3 RS232 CONNECTOR Not used. User guide TPM-RKE Analyzer Page 4/20 .4 DESCRIPTION OF THE INSTRUMENT ..1 POWER ON/OFF KEY KEY FUNCTION Power on: Press this key to power on the instrument. Power off: Press and hold the key (more than 3 seconds) to power off the instrument. ..1. Power on At power on, it displays the logo. Then it displays the software revision number. Then the tool displays the main menu and the operator can select desired function. ATEQ VT 60 Version 06.03 MAIN MENU > RKE TEST TPM FUNCTIONS SETTINGS User guide TPM-RKE Analyzer Page 5/20 .5 FRONT PANEL DESCRIPTION ..1 DISPLAY The LCD screen displays the parameters menus and the measurements results. ..2 LOW BAT MAIN MENU > RKE TEST TPM FUNCTIONS SETTINGS LIGHTS Battery level light: When this light is on, the battery level is too low, charge it. Pass test light: When this light is on, the instrument has correctly received the frame from the valve (or the RKE). PASS Fail test light: When this light is on, the instrument has not received the frame from the valve (or the RKE). FAIL Transmission light: When this light is flashing, the instrument is currently transmitting a 125 KHz frequency to activate a valve. TX CHARGE Battery charging light: This light turns on when the instrument is being charged. ..3 KEYS Power on and off the instrument. Navigation menu, "up". Navigation menu, "down". Select Key, press to enter in the chosen function or validate a parameter. Cancel key, return to the previous menu or function without parameter validation. Test Key, to initiate a test cycle. User guide TPM-RKE Analyzer Page 6/20 .6 BATTERY SUPPLY The instrument uses a Li-ion battery, the autonomy depends of the number of cycles carried out. It battery must be recharged with a 24 V DC external power supply (Included). ..1 BATTERY STATUS When the battery is too low, the "LOW BATT" light is flashing for 2 seconds and the instrument will powered off. LOW BATT PASS FAIL To see the battery status, select the "SETTINGS" menu using the and keys. Validate your entry with the By using the and key. keys, select the "BATTERY LEVEL" menu and validate with the MAIN MENU RKE TEST TPM FUNCTIONS > SETTINGS PARAMETERS MENU UNIT : METRIC AUTO OFF: DISABLE > BATTERY LEVEL key. The instrument displays the receivers and the battery status. Press the button to return to the main menu. RECEIVER 1: READY 2: READY BATTERY MAIN MENU > RKE TEST TPM FUNCTIONS SETTINGS User guide TPM-RKE Analyzer Page 7/20 TX .7 MEASUREMENT ..1 KEY MEASUREMENT (RKE TEST) This menu allows putting the instrument in key test mode (RKE). Select this mode with the key, the instrument invites you to launch the test by pressing the key. Wait a second for the initialization if the instrument. The instrument displays a horizontal bar and invites you to test the key fob. Hold the key fob near the antenna of the instrument (between 7 and 15 centimetres) and press any button of the key fob. The intensity of the RF signal force is indicated on the scale of the horizontal bar. The greater the key fob RF signal power, the greater the horizontal bar is filled. Press the button to return to the main menu. MAIN MENU > RKE TEST TPM FUNCTIONS SETTINGS EUROPE RKE TEST < TEST > TO START EUROPE 1997/E RF LEVEL PLEASE WAIT... EUROPE RKE TEST PRESS KEY FOB BUTTON EUROPE RKE TEST PRESS KEY FOB BUTTON MAIN MENU > RKE TEST TPM FUNCTIONS SETTINGS User guide TPM-RKE Analyzer Page 8/20 ..2 VALVE MEASUREMENT (TPM FUNCTIONS) Use the following directions to test the functionality of a TPM sensor: Select "TPM FUNCTION" by using the keys and validate using the By using the and and key. keys, select the model year of the valve to be tested and validate using the key (existing years from 1997 to 2006). MAIN MENU RKE TEST > TPM FUNCTIONS SETTINGS MODEL YEAR SELECTION > 1997 1998 1999 MODEL YEAR SELECTION 2004 2005 > 2006 ... BODY STYLE SELECTION Next, by using the and keys, select the body code of the valve to be tested and validate with the key (this code is in correspondence with a vehicle). Next, by using the and keys, select the key (you trigger selection and validate using the may select the mode you want to trigger on the valve, read, park, deactivation and sniffing). Then the instrument is displaying the valve characteristics chosen and waiting for a start cycle. To start cycle, press the key. > CS HB KJ LX RS > WK BODY STYLE SELECTION TRIGGER SELECTION > READ SENSOR PARK SENSOR DEACTIVATE SENSOR EUROPE 2006 .../WK PARK SENSOR < TEST > TO START User guide TPM-RKE Analyzer Page 9/20 LOW BATT PASS When the "TX" light is flashing, it indicates that the instrument is emitting a frame wirelessly to make the valve respond. First case: a valve is detected: When the instrument has detected a frame from the valve, the "PASS" light is on and it displays the valve characteristics. To locate the valve on the car, press the key. Then select the valve wheel location and press the key. The instrument confirms the location of the valve. And indicates the location valve on the car. TX EUROPE 2006 .../WK PARK SENSOR TRIGGER PROCESSING LOW BATT NB: the identifier displayed on the screen must be the same as the one written on the valve. FAIL PASS FAIL TX SENSOR DATAS 80AA323B 240 KPa SLEEP MODE TIRE LOCATION TIRE LOCATION > LEFT FRONT : EMPTY LEFT REAR1 : EMPTY LEFT REAR2 : EMPTY LEFT FRONT : STORED TIRE LOCATION > LEFT FRONT : OK LEFT REAR1 : EMPTY LEFT REAR2 : EMPTY Second case: no valve is detected: After a few moments, if no valve frame is detected, the "FAIL" light is on, so start a new test. LOW BATT PASS FAIL User guide TPM-RKE Analyzer Page 10/20 TX MAIN MENU Press the > RKE TEST TPM FUNCTIONS SETTINGS button to return to the main menu. ..1. Results explanation The picture below is an example of a valve data communication result: Tire internal pressure at sea level Valve identifier 80AA323B SENSOR DATAS 240 KPa SLEEP MODE