ATEQ ATEQ-VTXX intelligent tire pressure Analyzer User Manual Meeting Review

ATEQ Corp. intelligent tire pressure Analyzer Meeting Review

Manual

Download: ATEQ ATEQ-VTXX intelligent tire pressure Analyzer User Manual Meeting Review
Mirror Download [FCC.gov]ATEQ ATEQ-VTXX intelligent tire pressure Analyzer User Manual Meeting Review
Document ID661380
Application ID7lOuPNyredmzS4DhEFNXoQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.75kB (609329 bits)
Date Submitted2006-05-24 00:00:00
Date Available2006-05-24 00:00:00
Creation Date2006-04-19 16:40:27
Producing SoftwareOpenOffice.org 2.0
Document Lastmod2006-04-19 12:49:54
Document TitleMeeting Review
Document CreatorWriter
Document Author: Mike Crimmings

User’s manual
TPM-RKE Analyzer
9936
Version 06.03 Daimler Chrysler
Reference: QS-258DCA-U
User guide
REGULATORY STATEMENTS
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions;
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
“Changes or modifications not expressly approved by the manufacture could void the
user's authority to operate the equipment.”
“NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by the manufacturer may
violate the user's authority to operate the equipment.
Industries Canada:
The installer of this radio equipment must ensure that the antenna is located or pointed
such that it does not emit RF field in excess of Health Canada limits for the general
population; consult Safety Code 6, obtainable from Health Canada’s website
www.hc-sc.gc.ca/rpb"
User’s Manual
TABLE OF CONTENTS
User guide
TPM-RKE ANALYZER 9936............................................................................................. 2
.1 DESCRIPTION OF THE TPM-RKE ANALYZER 9936........................................................................ 2
.2 FEATURES.......................................................................................................................................... 3
..1 Radio frequencies........................................................................................................................... 3
..2 Type of valve.................................................................................................................................. 3
.3 CONNECTORS.................................................................................................................................... 4
..1 Supply connector............................................................................................................................ 4
..2 USB connector............................................................................................................................... 4
..3 RS232 connector............................................................................................................................ 4
.4 DESCRIPTION OF THE INSTRUMENT............................................................................................... 5
..1 Power on/off key............................................................................................................................. 5
.5 FRONT PANEL DESCRIPTION........................................................................................................... 6
..1 Display............................................................................................................................................ 6
..2 Lights.............................................................................................................................................. 6
..3 Keys................................................................................................................................................ 6
.6 BATTERY SUPPLY............................................................................................................................. 7
..1 Battery status.................................................................................................................................. 7
.7 MEASUREMENT.................................................................................................................................. 8
..1 Key measurement (RKE test)......................................................................................................... 8
..2 Valve measurement (TPM functions).............................................................................................. 9
.8 SETTINGS............................................................................................................................................ 12
..1 Parameters menu........................................................................................................................... 12
.9 STARSCAN.......................................................................................................................................... 16
..1 Data transfer................................................................................................................................... 16
..2 TPM/RKE Analyzer program up-dating........................................................................................... 16
.10 MENU STRUCTURE.......................................................................................................................... 17
..1 Main menu...................................................................................................................................... 17
.11 CORRESPONDANCES TABLES...................................................................................................... 19
..1 Vehicle / Body / valve..................................................................................................................... 19
..2 Countries / frequencies................................................................................................................... 19
................................................................................................................................................................ 19
Index
20
User guide TPM-RKE Analyzer Page 1/20
User guide
TPM-RKE ANALYZER 9936
.1
DESCRIPTION OF THE TPM-RKE ANALYZER 9936
The principal of this instrument is to awaken and then retrieve data from smart
valves mounted on vehicle wheels in order to verify their identifiers.
The instrument interacts with the smart valves without contact through wireless
communication.
LCD
Display
Light
Indicators
Keypad
RS232 (RJ45)
Connecter
USB
Connecter
User guide TPM-RKE Analyzer Page 2/20
.2
FEATURES
..1
RADIO FREQUENCIES
Awakening transmission frequency: 125 kHz (LF).
Reception frequencies: 433 MHz or 315 MHz (RF).
..2
TYPE OF VALVE
This instrument is especially designed for the measurement of the Siemens and
Schrader valves installed into Daimler-Chrysler vehicles.
Siemens
Siemens
Schrader
User guide TPM-RKE Analyzer Page 3/20
.3
CONNECTORS
..1
SUPPLY CONNECTOR
To supply the instrument and recharging the internal battery.
The voltage of the charger is a 24 V DC.
..2
USB CONNECTOR
The USB connector allows the instrument software programs to
be updated.
StarScan tool can retrieve information through the USB
connector.
..3
RS232 CONNECTOR
Not used.
User guide TPM-RKE Analyzer Page 4/20
.4
DESCRIPTION OF THE INSTRUMENT
..1
POWER ON/OFF KEY
KEY
FUNCTION
Power on: Press this key to power on the instrument.
Power off: Press and hold the key (more than 3
seconds) to power off the instrument.
..1. Power on
At power on, it displays the logo.
Then it displays the software revision number.
Then the tool displays the main menu and the operator
can select desired function.
ATEQ VT 60
Version 06.03
MAIN MENU
> RKE TEST
TPM FUNCTIONS
SETTINGS
User guide TPM-RKE Analyzer Page 5/20
.5
FRONT PANEL DESCRIPTION
..1
DISPLAY
The LCD screen displays the parameters menus and
the measurements results.
..2
LOW BAT
MAIN MENU
> RKE TEST
TPM FUNCTIONS
SETTINGS
LIGHTS
Battery level light: When this light is on, the battery level is too low, charge it.
Pass test light: When this light is on, the instrument has correctly
received the frame from the valve (or the RKE).
PASS
Fail test light: When this light is on, the instrument has not received the
frame from the valve (or the RKE).
FAIL
Transmission light: When this light is flashing, the instrument is
currently transmitting a 125 KHz frequency to activate a valve.
TX
CHARGE
Battery charging light: This light turns on when the instrument is being
charged.
..3
KEYS
Power on and off the instrument.
Navigation menu, "up".
Navigation menu, "down".
Select Key, press to enter in the chosen function or validate a parameter.
Cancel key, return to the previous menu or function without parameter validation.
Test Key, to initiate a test cycle.
User guide TPM-RKE Analyzer Page 6/20
.6
BATTERY SUPPLY
The instrument uses a Li-ion battery, the autonomy depends of the number of
cycles carried out. It battery must be recharged with a 24 V DC external power
supply (Included).
..1
BATTERY STATUS
When the battery is too low, the "LOW BATT" light is
flashing for 2 seconds and the instrument will
powered off.
LOW BATT
PASS
FAIL
To see the battery status, select the "SETTINGS"
menu using the
and
keys.
Validate your entry with the
By using the
and
key.
keys, select the
"BATTERY LEVEL" menu and validate with the
MAIN MENU
RKE TEST
TPM FUNCTIONS
> SETTINGS
PARAMETERS MENU
UNIT : METRIC
AUTO OFF: DISABLE
> BATTERY LEVEL
key.
The instrument displays the receivers and the battery
status.
Press the
button to return to the main menu.
RECEIVER
1: READY
2: READY
BATTERY
MAIN MENU
> RKE TEST
TPM FUNCTIONS
SETTINGS
User guide TPM-RKE Analyzer Page 7/20
TX
.7
MEASUREMENT
..1
KEY MEASUREMENT (RKE TEST)
This menu allows putting the instrument in key test
mode (RKE).
Select this mode with the
key,
the instrument invites you to launch the test by
pressing the
key.
Wait a second for the initialization if the instrument.
The instrument displays a horizontal bar and invites
you to test the key fob. Hold the key fob near the
antenna of the instrument (between 7 and 15
centimetres) and press any button of the key fob.
The intensity of the RF signal force is indicated on the
scale of the horizontal bar. The greater the key fob RF
signal power, the greater the horizontal bar is filled.
Press the
button to return to the main menu.
MAIN MENU
> RKE TEST
TPM FUNCTIONS
SETTINGS
EUROPE
RKE TEST
< TEST > TO START
EUROPE
1997/E
RF LEVEL
PLEASE WAIT...
EUROPE
RKE TEST
PRESS KEY FOB BUTTON
EUROPE
RKE TEST
PRESS KEY FOB BUTTON
MAIN MENU
> RKE TEST
TPM FUNCTIONS
SETTINGS
User guide TPM-RKE Analyzer Page 8/20
..2
VALVE MEASUREMENT (TPM FUNCTIONS)
Use the following directions to test the functionality of a TPM sensor:
Select "TPM FUNCTION" by using the
keys and validate using the
By using the
and
and
key.
keys, select the model
year of the valve to be tested and validate using the
key (existing years from 1997 to 2006).
MAIN MENU
RKE TEST
> TPM FUNCTIONS
SETTINGS
MODEL YEAR SELECTION
> 1997
1998
1999
MODEL YEAR SELECTION
2004
2005
> 2006 ...
BODY STYLE SELECTION
Next, by using the
and
keys, select the
body code of the valve to be tested and validate with
the
key (this code is in correspondence with a
vehicle).
Next, by using the
and
keys, select the
key (you
trigger selection and validate using the
may select the mode you want to trigger on the valve,
read, park, deactivation and sniffing).
Then the instrument is displaying the valve
characteristics chosen and waiting for a start cycle. To
start cycle, press the
key.
> CS
HB
KJ
LX
RS
> WK
BODY STYLE SELECTION
TRIGGER SELECTION
> READ SENSOR
PARK SENSOR
DEACTIVATE SENSOR
EUROPE
2006 .../WK
PARK SENSOR
< TEST > TO START
User guide TPM-RKE Analyzer Page 9/20
LOW BATT
PASS
When the "TX" light is flashing, it indicates that the
instrument is emitting a frame wirelessly to make the
valve respond.
First case: a valve is detected:
When the instrument has detected a frame from the
valve, the "PASS" light is on and it displays the valve
characteristics.
To locate the valve on the car, press the
key.
Then select the valve wheel location and press the
key.
The instrument confirms the location of the valve.
And indicates the location valve on the car.
TX
EUROPE
2006 .../WK
PARK SENSOR
TRIGGER PROCESSING
LOW BATT
NB: the identifier displayed on the screen must be the
same as the one written on the valve.
FAIL
PASS
FAIL
TX
SENSOR DATAS
80AA323B
240 KPa
SLEEP MODE
TIRE LOCATION
TIRE LOCATION
> LEFT FRONT : EMPTY
LEFT REAR1 : EMPTY
LEFT REAR2 : EMPTY
LEFT FRONT : STORED
TIRE LOCATION
> LEFT FRONT : OK
LEFT REAR1 : EMPTY
LEFT REAR2 : EMPTY
Second case: no valve is detected:
After a few moments, if no valve frame is detected, the
"FAIL" light is on, so start a new test.
LOW BATT
PASS
FAIL
User guide TPM-RKE Analyzer Page 10/20
TX
MAIN MENU
Press the
> RKE TEST
TPM FUNCTIONS
SETTINGS
button to return to the main menu.
..1. Results explanation
The picture below is an example of a valve data communication result:
Tire internal
pressure at
sea level
Valve
identifier
80AA323B
SENSOR DATAS
240 KPa
SLEEP MODE