    Refer to Supplemental Information (next page) for complete descriptions of these installation steps  FlexGuard® 5853AP Wireless Glassbreak Detector Installation Instructions 5853AP Glassbreak Detector Internal Parts  CR-123ACR-123AMounting HoleMounting HoleBatteriesFront Tamper SwitchLED IndicatorsMicrophoneSensitivity SwitchesWall Tamper (behind battery)Test Mode pads (on PCB)Front CoverLatchBreak out flashfor cover screw21ONOFF5853_001-v0  Connect Batteries Remove pull tab to connect batteries     Select Mounting Location For the best detector performance, select a mounting location that is: •  within 7.6 m (25 feet) of the protected glass; •  within clear view of the protected glass; •  at least 2 m (6.5 feet) from the floor; •  at least 1 m (3.3 feet) from forced air ducts; •  at least 1 m (3.3 feet) from sirens or bells greater •  than 5 cm (2 inches) in diameter. •  between the protected glass and any heavy window coverings that may be present. Alternatively, when heavy window coverings are present, the detector can be mounted on the frame of the window. Avoid mounting the detector on the same wall as the protected glass, on free-standing posts or pillars, or in rooms with noisy equipment (air compressors, bells, power tools, etc.), if this equipment is operated when the detector is armed.  Wall Mount (Top View)WallMnt-001-V0  CeilingMnt-001-V0Ceiling Mount: (Side View)  NOTE:  If the device is ceiling mounted, the end with the hole (Microphone end) should face the protected glass.   Set Sensitivity (Range)  SENS2SENS1CR-123ACR-123ASENS2SENS15853_004-v0ONOFF   SENS1 & SENS2 configure sensitivity SENSITIVITY  APPROXIMATERANGE  SENS1 SENS2 MAX  7.6m (25 ft)  OFF OFF MEDIUM  4.6m (15 ft)  ON OFF LOW  3m (10 ft)  OFF ON LOWEST  1.5m (5 ft)  ON ON  NOTE:  Ranges are approximate and vary with each room’s acoustic properties.  Always verify range with a  FlexGuard FG-701 Glassbreak Simulator.  Enroll Detector Refer to text and control panel's installation instructions.   When programming the transmitter, specify: •  Input Type = 3 (Supervised RF) •  Loop Number = 1  Mount Detector  •  Use mounting holes as a template to mark mounting locations on ceiling or wall. • If using the optional back tamper, remove the batteries, then mark the wall tamper location through its mounting hole. •  Mount detector using appropriate hardware. NOTE:  A screw capture feature designed to make ceiling mounting easier will cause some resistance when inserting the screw into the plastic. •  Close detector cover when finished.  CR-123ACR-123ASENS2SENS15853_003-v2(Screw not supplied.)3.5 mm x 38 mm(#6 x 1-1/2")3.5 mm x 38 mm(#6 x 1-1/2")#6 (3.5 mm) screw for Optional Rear Tamper*3.5 mm (#6) screws works bestwith the screw retention feature.To work properly, the back tamperscrew must be screwed into  a framing stud or a heavy-dutyhollow-wall anchor, such as a #8 self-tapping anchor.  This type of back tamper is not suitable for use on acoustic ceiling tile.   *The screw retention feature simplifies installation:  A rib in the screw cavity lightly holds the screw in place when installing the detector.   Test Detector Installation Enter Test Mode using a FlexGuard FG-701 Glassbreak Simulator (see Testing the Detector on the next page).  To enter Test Mode manually, short the Test Mode pads (as shown below).  CR-123ACR-123ASENS2SENS1SENS2SENS15853_005-v0TESTTEST Install Cover Screw (optional)  5853_006-V12.9 mm (#4) screw, 6 mm (1/4-in.) long       800-04905A Page 1
Download:
Mirror Download [FCC.gov]
Document ID1148742
Application IDcDMYB+uQ5Z0VthLpJ6teyg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize23.92kB (298989 bits)
Date Submitted2009-08-04 00:00:00
Date Available2009-08-04 00:00:00
Creation Date2009-07-22 14:09:07
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2009-07-27 09:24:20
Document TitleIS 320 Installation Guide
Document CreatorAcrobat PDFMaker 7.0.7 for Word
Document Author: Bill Miller
FCC ID Filing: CFS8DL5853AP

Navigation menu