Alcatel USA 8705U-16 Digitally Modulated Radio User Manual 00 Book I 6 fullTOC
Alcatel USA Marketing, Inc. Digitally Modulated Radio 00 Book I 6 fullTOC
Contents
- 1. User Manuel Part 1
- 2. User Manuel Part 2
User Manuel Part 1
MDR-8000/i/s/u Microwave Digital Radios Users Manual Alcatel Part Number 3EM15726AA Issue 2, June, 2004 Part 1 of 2 3400 West Plano Parkway Plano, Texas 75075-5813 U.S.A. Table of Contents Page Section 1 General 1.1 INTRODUCTION ............................................................................................. 1-1 1.2 CONTENT ....................................................................................................... 1-1 Section 2 Operation 2.1 GENERAL ........................................................................................................ 2-1 2.2 TURN-ON ........................................................................................................ 2-1 2.3 USER SYSTEM INTERFACE (USI) PROVISIONING FUNCTION/OPERATION ...... 2-2 2.4 OPERATING PROCEDURES .............................................................................. 2-2 2.4.1 Radio Receiver Manual Switching ..................................................................... 2-2 2.4.2 Radio Transmitter Manual Switching ................................................................. 2-5 2.4.3 Radio I/O Interface Manual Switching .............................................................. 2-5 2.4.4 MCS-11 Operation .......................................................................................... 2-7 2.4.5 Lamp Tests ....................................................................................................... 2-8 2.4.6 Alarm Checks .................................................................................................. 2-8 2.4.7 Orderwire Operation ....................................................................................... 2-8 2.4.8 Initiating Outgoing Orderwire Calls .................................................................. 2-8 2.4.9 Answering Incoming Orderwire Calls ................................................................ 2-8 2.5 TURN-OFF PROCEDURE ................................................................................... 2-9 2.6 EMERGENCY OPERATION .............................................................................. 2-9 2.7 MODEM OPERATION ...................................................................................... 2-9 2.8 CONTROLS, INDICATORS, TEST POINTS, AND CONNECTORS ....................... 2-9 Section 3 Interconnect 3.1 SECTION INTRODUCTION .............................................................................. 3-1 3.2 INSTALL POWER CABLE ASSEMBLIES ............................................................... 3-1 TOC-i Page 3.3 PDU STRAPPING AND CONNECTIONS ........................................................... 3-3 3.4 SHELF/RACK ALARM CONNECTION .............................................................. 3-5 3.5 DS1 CONNECTIONS (J303 IN AND J304 OUT) .............................................. 3-8 3.6 DS1 REPEATER (J314 ON ONE SHELF TO J314 ON SECOND SHELF) ............ 3-10 3.7 DS3 LBO STRAPPING AND CONNECTIONS ................................................. 3-11 3.8 DS3 LBO DS3 BNC CONNECTIONS (J21 THROUGH J26 ) ............................. 3-12 3.9 DS3 LBO WAYSIDE DS1 CONNECTIONS (J201 IN AND J202 OUT ) ............. 3-13 3.9.1 Wayside DS1 Terminal .................................................................................. 3-14 3.9.2 Wayside DS1 Repeater .................................................................................. 3-15 3.10 DS3 REPEATER (J401 ON ONE SHELF TO J401 ON SECOND SHELF) ............ 3-15 3.11 FIBER OPTIC CABLE CONNECTIONS ............................................................. 3-16 3.11.1 2 or 4 Fiber Management Panel ..................................................................... 3-17 3.11.2 2x4 Fiber Switched Management Panel .......................................................... 3-17 3.12 OC3 AUX INTERFACE BOARD WAYSIDE DS1 CONNECTIONS (J201 IN AND J202 OUT) .............................................................................. 3-20 3.12.1 Wayside DS1 Terminal .................................................................................. 3-20 3.12.2 Wayside DS1 Repeater .................................................................................. 3-20 3.13 OC3 REPEATER (J203 ON ONE SHELF TO J203 ON SECOND SHELF) ........... 3-21 3.14 USI/CONTROLLER CABLE CONNECTION TO LAPTOP (J301) ......................... 3-22 3.15 SERVICE CHANNEL ....................................................................................... 3-22 3.15.1 Handset Jack ................................................................................................. 3-23 3.15.2 Service Channels Provisioning Options ............................................................ 3-24 3.15.3 Audio 1, Audio 2 (J316, J317) ....................................................................... 3-24 3.15.4 RS-232-1, RS-232-2 (J312, J313) .................................................................... 3-27 3.15.5 MCS-11 Connections ..................................................................................... 3-28 3.15.6 ELMC (J315, J318) ........................................................................................ 3-37 3.16 FOREIGN ALARM INTERFACE (J305) ............................................................. 3-41 3.17 ALARM, STATUS, CONTROLS INTERCONNECT ............................................. 3-44 3.17.1 Controller Bus ................................................................................................ 3-46 3.17.2 Control Inputs ................................................................................................ 3-46 3.17.3 Station Alarm Inputs/TBOS Interface ............................................................... 3-46 TOC-ii Page 3.17.4 Station Alarm Wiring ..................................................................................... 3-47 3.17.5 Relay Alarm/Status Outputs ............................................................................ 3-48 3.17.6 Relay Control Outputs .................................................................................... 3-51 Section 4 Initial Turnup 4.1 SECTION INTRODUCTION .............................................................................. 4-1 4.2 RECOMMENDED SEQUENCE ......................................................................... 4-1 4.3 PROVISIONING RADIO ................................................................................... 4-3 Section 5 Maintenance 5.1 GENERAL ........................................................................................................ 5-1 5.2 MAINTENANCE PHILOSOPHY ......................................................................... 5-2 5.3 SPECIAL TOOLS ............................................................................................... 5-4 5.4 PERSONAL COMPUTER (PC) ............................................................................ 5-4 5.5 ALARM MONITORING AND INSPECTION ....................................................... 5-4 5.6 RECOMMENDED PERIODIC CHECKS ............................................................... 5-6 5.7 TROUBLESHOOTING ....................................................................................... 5-6 5.7.1 Test Procedures ................................................................................................ 5-6 5.7.2 Linear/Ring Radio Troubleshooting ................................................................... 5-6 5.7.3 Ring Radio Troubleshooting ............................................................................ 5-18 5.8 MODULE REPLACEMENT ............................................................................... 5-19 5.9 CHANGING FREQUENCY ............................................................................. 5-22 5.10 CLEANING.................................................................................................... 5-22 Appendix A CommPak Indoor Shelf A.1 COMPONENT LOCATIONS AND OPTIONS ....................................................A-1 A.1.1 External Fan Assembly ......................................................................................A-5 A.2 INTERCONNECT .............................................................................................A-5 A.2.1 Power Cable Assembly .....................................................................................A-5 A.2.2 External Fan Assembly ......................................................................................A-8 A.2.3 SHELF/RACK ALARM CONNECTION ..............................................................A-9 TOC-iii Page A.2.4 DS1 LBO Connections ....................................................................................A-11 A.2.5 DS3 LBO CONNECTIONS .............................................................................A-13 A.2.6 Fiber Optic Cable Connections .......................................................................A-15 A.2.7 OC3 AUX Interface Board Connections ...........................................................A-16 A.2.8 Controller Cable Connection (J301) ................................................................A-18 A.2.9 Audio Cable Connections ...............................................................................A-18 A.2.10 RS-232 Cable Connections .............................................................................A-19 A.2.11 MCS-11 Cable Connections ...........................................................................A-20 A.2.12 ELMC Cable Connections ...............................................................................A-24 A.2.13 Foreign Alarm Interface (J305) ........................................................................A-25 A.2.14 Station Alarm Wiring .....................................................................................A-27 A.3 MAINTENANCE ............................................................................................A-28 A.3.1 Warnings and Cautions .................................................................................A-28 A.3.2 Troubleshooting .............................................................................................A-28 A.3.3 Module Replacement ......................................................................................A-28 A.4 CAPACITY UPGRADE DS1 TO DS3 OR DS3 TO OC3 .....................................A-37 A.5 CHANGING SYSTEM SOFTWARE .................................................................A-37 TOC-iv 1 GENERAL 1.1 INTRODUCTION This MDR-8000 Users Manual contains information on the MDR-8000 Hot-Standby Shelf, MDR-8000 CommPak Indoor Shelf, and MDR-8000 CommPak Outdoor Unit as follows: MDR-8000 Hot-Standby Shelf – Section 1 through Section 5 MDR-8000 CommPak Indoor Shelf – Appendix A MDR-8000 CommPak Outdoor Unit – Appendix B (to be supplied) The information in the Users Manual is a summary of the overall instruction book that is located on the attached CD. The summary information is provided to support initial turnup, day-to-day operation, and maintenance of the MDR-8000 equipment. 1.2 CONTENT Refer to Table 1-1. The MDR-8000 Instruction Book Section/Appendix column lists the parts of the MDR-8000 Instruction Book, PN 3DH03220. A check mark under the Users Manual column or the Instruction Book CD column indicates that this information is located in either the Users Manual, the Instruction Book, or both. Table 1-1 Information Location Location Section/Appendix Users Manual MDR-8000 Instruction Book Glossary √ General √ Application √ Functional Description √ Physical Installation √ Interconnect √ √ Initial Turnup √ √ Operation √ √ Users Guide Maintenance √ √ √ Diagrams √ Rack Installation √ Alarm/Status/Control √ MCS-11 Reference Guide √ Modem Provisioning √ Maintenance Support Procedures √ CommPak Indoor Shelf √ √ 1-1 AE–37Y CONTROLLER C1 S E LE CT A3 AND B3 I/O INTFC MODULES B Y DATA RATE CE–16BB POWER SUPPLY A1 AE-27AA TMN INTFC OR BLANK C3 I/O INTFC A3 UD–36A( ) RCVR A2 UD–51( ) PWR AMP A5 AE–27AF UD–35A( ) RELAY XMTR INTFC A4 C2 I/O INTFC B3 UD–36A( ) RCVR B2 CE–16BB UD–35A( ) POWER XMTR SUPPLY B4 B1 UD–51( ) PWR AMP B5 ALM INSVC WYSD ON WYSD ALM XMT AUX OC3 IN SC ALM OC3 ALM RCVR ON OC3 OUT RAD LOF ALM WYSD DS1 ON LINE WYSD ALM LBO/OC3 AUX INTFC SYNC ALM ALM RAD DADE 23 56 78 ON LINE 901 COMMON LOSS ALM DS3 ALIGN SELECT LBO/OC3 AUX INTFC TO MATCH I/O INTFC (DATA RATE) DS1/E1 LBO DX-35P OC3 DS3 LBO DX-35N DS3 OC3 AUX INTFC LMW-7030-SM 06/09/04 DX - 35M DS 1/E I Figure 1-1 Typical MDR-8000 Hot-Standby Shelf Component Locations and Options (Sheet 1 of 3) 1-2 ) AE–37Y CONTROLLER C1 CE–16BB POWER SUPPLY A1 I/O INTFC B3 UD–51( ) UD–51( ) UD–36A( ) PWR AMP PWR AMP RCVR A5 B5 B2 AE–27AF CE–16BB RELAY POWER UD–35A( ) UD–35A( ) INTFC SUPPLY XMTR XMTR C2 B1 A4 B4 I/O INTFC A3 UD–36A( ) RCVR A2 LBO/OC3 AUX INTFC SELECT XTAL OSCILLATOR SUBBOARD BY CRYSTAL FREQUENCY. SELECT CAPACITY KEY BY DATA RATE. OC3 D S3 D S1 / E1 SELECT OC3 CAPACITY KEY BY NUMBER OF STS1 LINES – 1 OR 3 LINES. SELECT DS3 CAPACITY KEY BY NUMBER OF LINES – 1, 2, OR 3 LINES. SELECT DS1/E1 CAPACITY KEY BY CAPACITY AND MODULATION SCHEME 2, 4, 8, 12, 16 DS1/E1 AND 32 OR 128 TCM. LMW-9051-SM 02/15/04 Figure 1-1 Typical MDR-8000 Hot-Standby Shelf Component Locations and Options (Sheet 2 of 3) 1-3 HEAT SINK RF SWITCH ISOLATORS RCV ANT XMT RCV B-SIDE POWER RF SWITCH DIPLEXER FILTER A-SIDE POWER DIPLEXER FILTER MOUNTING BRACKET ISOLATOR REAR VIEW (TYPICAL HOT-STANDBY 1:10 COUPLER SINGLE ANTENNA CONFIGURATION) Note Location of A and B RCV ports on diplexer filter varies, depending on RF frequency. For some frequencies, A and B ports reverse location. LMW-7211-SM 06/08/04 Figure 1-1 Typical MDR-8000 Hot-Standby Shelf Component Locations, and Options (Sheet 3 of 3 ) 1-4 2 OPERATION GENERAL This section contains turn-on, normal operation, turn-off, and emergency operating procedures plus a description of controls. indicators, test points, and connectors for the MDR-8000 Series Microwave Digital Radios. 2.1 Note Before performing any procedures, operating personnel should become familiar with the locations of power distribution units and circuit breakers. If an equipment performance problem occurs during the following procedures, refer to the Maintenance section. 2.2 TURN-ON The radio is designed to operate continuously without operator intervention. After initial installation and power turn-on, operating procedures are limited to periodic visual lamp checks, alarm checks, and answering or initiating orderwire service calls. Turn-on procedures are needed only if the system has been turned off due to a malfunction or during maintenance. WARNING Possibility of Damage to Equipment Exposure to energy radiated at microwave frequencies can cause eye damage and eventual blindness. Do not operate the system with either the transmit or the receive waveguide port unterminated. Do not look into the waveguide run or the antenna of an operating radio. Note Until all radios in the transmission link are interconnected, turned on, and operating properly, alarm conditions may exist. Perform the following procedure to turn on the MDR-8000 series radios: On all power supply modules, set power ON/OFF switches to ON. Verify that power distribution unit rack alarm indicator (if any) is not lighted. If indicator is lighted, troubleshoot as described in the Maintenance section. Verify that no red indicators are lighted. If a red indicator is lit, troubleshoot as described in the Maintenance section. Perform lamp test by momentarily holding OVRD-ACO/LT switch on controller to ACO/LT. All indicator lamps/LEDs should light. 2-1 2.3 USER SYSTEM INTERFACE (USI) PROVISIONING FUNCTION/OPERATION The User System Interface (USI) software is used for maintenance and support of the radio including fault and status reporting. Refer to the Initial Turn-Up section for instructions on loading and running the software. Refer to the User’s Guide section for descriptions and functions of the menus. Note Refer to the Software Release Notes before performing any operating, provisioning, or maintenance function on this equipment. The Software Release Notes may contain information affecting these functions that is not contained in this instruction manual. 2.4 OPERATING PROCEDURES Note The USI computer is the main control for the radio. If instructions for setting up the USI computer are needed, refer to Initial Turn-Up section. After installation and turn-on, operating procedures are limited to periodic alarm checks and, when necessary, answering or initiating orderwire calls. Automatic and manual switching are provided for equipment protection. Manual switching may be accomplished using the Control screen on the USI computer or the switches on the front panel of the controller module. The following paragraphs provide operating procedures for manual switchover of protected radio systems. 2.4.1 Radio Receiver Manual Switching Note When used in conjunction with a RCVR manual switch, press the OVRD switch to lock the receiver on line regardless of alarms. Press again to unlock. Controller Switch Perform RCVR manual switch (Figure 2-1) using controls on front panel of controller module: USI Switch Perform RCVR manual switch (Figure 2-2) using the USI control screen. 2-2 ALM OFF NORM TOGGLE SWITCH LEFT TO SWITCH A XMTR, RCVR, OR I/O MODULE IN-SERVICE AND TOGGLE SWITCH RIGHT TO SWITCH B XMTR, RCVR, OR I/O MODULE IN-SERVICE. SHLF ALM ALM ON LINE TX ALM ON LINE RX ALM ON LINE I/O NOTE OVERRIDE (OVRD) LOCKS XMTR, RCVR, OR I/O MODULE, SELECTED ABOVE IN-SERVICE, REGARDLESS OF ALARMS. TO ENABLE OVERRIDE: 1. PRESS AND HOLD TX A/B ON LINE, RX A/B ON LINE, OR I/O A/B ON LINE SWITCH. 2. TOGGLE ACO/LT OVRD SWITCH TO OVRD POSITION. 3. RELEASE A/B ON LINE SWITCH. POLL LCL RMT RSP RSP CMD RF RPTR IDLE TO DISABLE OVERRIDE: TOGGLE ACO/LT OVRD SWITCH TO OVRD POSITION. LMW-5078-sm 08/15/02 Figure 2-1 Manual Switch From Controller Front Panel 2-3 1. OPEN USI CONTROLS SCREEN. Controls -- MDR-8000 DS3 File View Setup Options F4 Alarm Status F5 F6 Analog Monitor F7 Performance F8 Station Alarm User Control F9 Provisioning LOCAL CONTROLS ELMC Address: J7915 Description: SILVERTON Communicating* IN-SERVICE DS1 LINE LOOP-BACK RCV to XMT A Transmitter On Line A Receiver On Line Line 1 loopback 2. SELECT RCVR TO PUT IN-SERVICE. Line 2 loopback SYSTEM LOOP-BACK 3. SELECT YES ON CONFIRMATION MESSAGE Line 3 loopback CONTROLS AUSER I/O LOOPBACK TO ENABLE FUNCTION. B Receiver On Line Control #1 B I/O 4. LOOPBACK VERIFY GREEN IN-SERVICE STATUS CIRCLE DISPLAYS. A I/O On Line Control #2 B I/O On Line Control #3 A ATPC HIGH Power Lock Control #4 B ATPC HIGH Power Lock Control #5 A ATPC LOW Power Lock Control #6 B Transmitter On Line B ATPC LOW Power Lock Thursday, November 30, 2000 1:44:19 PM USI Version R1.02 Controller Version R1.02 LMW-5081-sm 08/15/02 Figure 2-2 RCVR Manual Switch Using USI Control Screen 2-4 2.4.2 Radio Transmitter Manual Switching CAUTION Possibility of Service Interruption Switching the radio transmitter may momentarily interrupt traffic. Before switching the transmitter, obtain permission from the proper authority. Note When used in conjunction with a XMTR manual switch, press the OVRD switch to lock the XMTR on line regardless of alarms. Press again to unlock. Controller Switch Perform XMTR manual switch (Figure 2-1) using controls on front panel of controller module. USI Switch Perform XMTR manual switch (Figure 2-3) using the USI control screen. 2.4.3 Radio I/O Interface Manual Switching CAUTION Possibility of Service Interruption Traffic and auxiliary channel service will be momentarily interrupted. Obtain proper authorization before making this switch. Note When used in conjunction with an I/O interface manual switch, press the OVRD switch to lock the I/O interface on line regardless of alarms. Press again to unlock. 2-5 Controls -- MDR-8000 DS3 File View Setup Options F4 F5 Alarm Status F6 Analog Monitor F7 Performance F8 Station Alarm User Control F9 Provisioning LOCAL CONTROLS ELMC Address: J7915 Description: SILVERTON Communicating* 1. SELECT XMTR TO PUT IN-SERVICE. IN-SERVICE SYSTEM LOOP-BACK A Transmitter On Line 2. SELECT YES ON CONFIRMATION MESSAGE A I/O TO LOOPBACK ENABLE FUNCTION. Line 1 loopback B Transmitter On Line A Receiver On Line DS1 LINE LOOP-BACK RCV to XMT Line STATUS 2 loopback B I/O LOOPBACK 3. VERIFY GREEN IN-SERVICE CIRCLE DISPLAYS. Line 3 loopback USER CONTROLS B Receiver On Line Control #1 A I/O On Line Control #2 B I/O On Line Control #3 CAUTION Possibility of Service Interruption Control #4 Switching the radio transmitter may momentarily interrupt Control #5 Switching I/Os will momentarily interrupt traffic and traffic. B ATPC HIGH Power Lock Control #6 auxiliary channel service. Before switching, obtain permission ATPC LOW LOW Power Lock Lock B ATPC Power Thursday, November 30, 2000 1:44:19 PM USI Version R1.02 Controller Version R1.02 from the proper authority. A ATPC HIGH Power Lock LMW-5076-SM 06/12/04 Figure 2-3 XMTR Manual Switch Using USI Control Screen Controller Switch Perform I/O manual switch (Figure 2-1) using controls on front panel of controller module. USI Switch Perform I/O manual switch (Figure 2-4) using the USI control screen. 2-6 1. OPEN USI CONTROLS SCREEN. Controls -- MDR-8000 DS3 File View Setup Options F4 F5 Alarm Status F6 Analog Monitor F7 Performance F8 Station Alarm F9 User Control Provisioning LOCAL CONTROLS ELMC Address: J7915 Description: SILVERTON Communicating* IN-SERVICE SYSTEM LOOP-BACK DS1 LINE LOOP-BACK RCV to XMT A Transmitter On Line A I/O LOOPBACK Line 1 loopback B Transmitter On Line B I/O LOOPBACK Line 2 loopback A Receiver On Line USER CONTROLS 2. SELECT I/O INTERFACE MODULE TO PUT IN-SERVICE. B Receiver On Line A I/O On Line Control #1 3. SELECT YES ON CONFIRMATION MESSAGE TO#2 ENABLE FUNCTION. Control B I/O On Line Control #3 GREEN IN-SERVICE STATUS CIRCLE DISPLAYS. 4. VERIFY A ATPC HIGH Power Lock Control #4 B ATPC HIGH Power Lock Control #5 A ATPC LOW Power Lock Control #6 Line 3 loopback B ATPC LOW Power Lock Thursday, November 30, 2000 1:44:19 PM USI Version R1.02 Controller Version R1.02 LMW-5077-sm 08/15/02 Figure 2-4 I/O Manual Switch Using USI Control Screen 2.4.4 MCS-11 Operation An Operational Support System (OSS) provides a means to remotely monitor and control an MDR-8000 radio via an MCS-11 Monitor and Control System polling master. A Remote Station Summary (RSS), a Remote Detail Scanner (RDS), a Remote Analog Scanner (RAS), and a Remote Control Decoder (RCD) are available at the polling master for each radio network element. The remote station OSS addresses are programmed during radio provisioning using the USI laptop computer. (Refer to radio provisioning in the Initial Turn-Up section.) Refer to Appendix A at the end of this instruction book for MCS-11 details, including alarm/status mapping and connector information. 2-7 2.4.5 Lamp Tests Perform lamp tests by pressing and holding ACO/LT OVRD switch on controller front panel in ACO/LT position. All indicators on controller and indicators on all equipped modules should light. Release ACO/LT OVRD switch. 2.4.6 Alarm Checks The USI Alarm and Status screens provide alarms and status for the radio. Refer to description of alarms and status in the maintenance section. 2.4.7 Orderwire Operation These operating procedures describe use of the orderwire system to answer incoming calls and initiate outgoing calls. The DTMF function allows the user to ring the dialed station. 2.4.8 2.4.9 Initiating Outgoing Orderwire Calls Connect telephone to J302 TEL jack on front panel of AE-37( ) Controller. Dial the 3-digit DTMF extension on the telephone keypad to call specific party or press the * key on keypad to initiate CALL signaling to all stations. Answering Incoming Orderwire Calls Note Call can be heard by all stations. When the buzzer sounds, alerting the operator there is an incoming call, connect telephone to J302 TEL jack on front panel of AE-37( ) Controller and turn ON-HOOK/OFF-HOOK switch to OFF-Hook position. To terminate call, turn ON-HOOK/OFF-HOOK switch to ON-Hook position. Note During the DTMF dialing process, if an incorrect number sequence has been dialed, press # to reset DTMF digit accumulator to zero. A redial can then be initiated. Note If 1.5 seconds elapse between dialed digits, the DTMF digit accumulator resets to zero, and a redial must be initiated. 2-8 Note Caller can press # to clear all flashing CALL indicators at all DTMF sites equipped with the DTMF signaling option (a tone is transmitted). TURN-OFF PROCEDURE The radio is designed for continuous operation. If power must be removed while performing maintenance on a particular cabinet or shelf, power can be removed by turning off associated power supplies. 2.5 Note Normally, the turn-off procedures are not used. System design allows maintenance of the rack without interrupting service. It is recommended that turn-off be performed only in an emergency. EMERGENCY OPERATION If an emergency occurs, such as a short circuit or a fire, turn off all MDR-8000 Microwave Digital Radio power supplies as quickly as possible. 2.6 MODEM OPERATION Refer to the Modem Provisioning section for modem connection and setup procedures. 2.7 2.8 CONTROLS, INDICATORS, TEST POINTS, AND CONNECTORS CAUTION Possibility of Service Interruption Do not adjust controls unless instructed to do so in an installation or maintenance procedure. Unauthorized adjustment of controls illustrated and described in this section may interrupt traffic and/or degrade system performance. Controls, indicators, test points, and connectors used in normal operation or referenced in procedures are shown in Figure 2-5 through Figure 2-16. The figures are arranged in alphabetical order according to the type number. 2-9 RED LED INDICATES MODULE FAULT OR REBOOT IN PROGRESS. ALM 9-PIN D-TYPE CONNECTOR FOR INTERFACE WITH COMPUTER. DUAL-COLOR LED (GREEN/YELLOW) LIGHTS GREEN TO INDICATE LINK IS ACTIVE. BLINKS GREEN WHEN RECEIVING DATA PACKETS ON PORT. LIGHTS YELLOW TO INDICATE PORT IS MISCONFIGURED. BLINKS YELLOW TO INDICATE COLLISIONS. PPP DUAL-COLOR LED (GREEN/YELLOW) LIGHTS GREEN TO INDICATE LINK IS ACTIVE. BLINKS GREEN WHEN RECEIVING DATA PACKETS ON PORT. LIGHTS YELLOW WHEN RECEIVING IDLE SIGNAL (LINK IS NOT ESTABLISHED). BLINKS YELLOW WHEN LINK IS NOT ESTABLISHED, BUT PACKETS ARE BEING RECEIVED. LMW-8043-SM 07/01/03 Figure 2-5 AE-37AA TMN Interface Module Controls, Indicators, and Connectors (Sheet 1 of 2) 2-10 ETHERNET 1 RJ-45 CONNECTOR FOR UPLINK CONNECTION TO ETHERNET HUB, SWITCH OR ROUTER ETH 1 UPLINK ETH 2 ETHERNET 2 AND 3 RJ-45 CONNECTORS FOR NORMAL/BRIDGED CONNECTION TO OTHER SNMP PORTS OF OTHER NEs (RADIO, MUX, COMPUTERS) POINT-TO-POINT (PPP) RJ-45 CONNECTOR FOR CONNECTION TO OTHER RADIO TMN INTFC PPP PORTS. CAN SUPPORT BACKHAUL CONNECTION OVER CHANNEL BANK OR SYNCHRONOUS MODEM WITH APPROPRIATE CABLE J1 J2 DS1 ETH 3 PPP J3 J4 DS2 DS3 C3A DS4 DS5 PQ/ECRC SUBBOARD C3B FLASH CARD NOTE: LEDs ARE DESIGNATED DS1-DS5 LMW-8047-SM 06/19/03 Figure 2-5 AE-37AA TMN Interface Module Controls, Indicators, and Connectors (Sheet 2 of 2) 2-11 YELLOW LED INDICATES ONE OR MORE SOFTWARE OVERRIDES IN PROCESS OR ONE OR MORE SWITCHES ACTIVATED. RED LED INDICATES CONTROLLER FAILED. FLASHING LED INDICATES INCORRECT FIRMWARE LOAD. RED LED INDICATES XMTR A FAILED. RED LED INDICATES ANY MODULE IN SHELF FAILED. RED LED INDICATES XMTR B FAILED. GREEN LED INDICATES XMTR A IN SERVICE. ALM OFF NORM RED LED INDICATES RCVR A FAILED. SHLF ALM GREEN LED INDICATES XMTR B IN SERVICE. ALM GREEN LED INDICATES RCVR A IN SERVICE. ON LINE TX MOMENTARY SWITCH SELECTS RCVR A (PRESS LEFT AND RELEASE) OR RCVR B (PRESS RIGHT AND RELEASE). RED LED INDICATES I/O INTFC A FAILED. MOMENTARY SWITCH SELECTS XMTR A (PRESS LEFT AND RELEASE) OR XMTR B (PRESS RIGHT AND RELEASE). ALM RED LED INDICATES RCVR B FAILED. ON LINE RX GREEN LED INDICATES RCVR B IN SERVICE. ALM GREEN LED INDICATES I/O INTFC A IN SERVICE. MOMENTARY SWITCH SELECTS I/O INTFC A (PRESS LEFT AND RELEASE) OR I/O INTFC B (PRESS RIGHT AND RELEASE). MOMENTARY SWITCH SELECTS ALARM CUTOFF (ACO) AND LAMP TEST (LT) (PRESS LEFT AND RELEASE) OR OVERRIDE (OVRD) (PRESS RIGHT AND RELEASE). LT LIGHTS ALL LEDs ON SHELF MODULES. OVRD LATCHES STATE OFF THE A/B TX SW, A/B RX SW, AND A/B I/O SW AND OVERRIDES SOFTWARE CONTROL OF ONLINE ENABLE SIGNALS. GREEN LED FLASHING PATTERN INDICATES STATUS OF SERVICE CHANNEL OVER THE RF PATH IN A RING. SEE CHART FOR PATTERN. ON LINE I/O RED LED INDICATES I/O INTFC B FAILED. POLL RSP LCL RMT RSP CMD RF RPTR GREEN LED INDICATES I/O INTFC B IN SERVICE. FLASHING GREEN LED INDICATES ACTIVE POLLING. FLASHING GREEN LED INDICATES DATA ACTIVITY IN RESPONSE TO LOCAL POLL. IDLE FLASHING GREEN LED INDICATES DATA ACTIVITY IN RESPONSE TO REMOTE POLL. GREEN LED FLASHING PATTERN INDICATES STATUS OF SERVICE CHANNEL OVER THE RPTR LINK IN A RING. SEE CHART FOR PATTERN. GREEN LED INDICATES LOSS OF SERVICE CHANNEL OVER RF PATH IN A RING. GREEN LED INDICATES LOSS OF SERVICE CHANNEL OVER THE RPTR LINK IN A RING. 9-PIN, D-TYPE FEMALE CONNECTOR IS USI COMPUTER INTERFACE PORT. STANDARD 2-WIRE TELEPHONE JACK. LMW-3150-sm 06/12/04 Figure 2-6 AE-37( ) Controller Controls, Indicators, and Connectors (Sheet 1 of 2) 2-12 C1 ELMC OPTION KEY J2 C1A EPLD PROGRAMMING CONNECTOR (FACTORY TEST PURPOSES ONLY) C1B P1 C1C LMW-7047 07/18/02 Figure 2-6 AE-37( ) Controller Controls, Indicators, and Connectors (Sheet 2 of 2) 2-13 Table 2-1 DS1/E1 Ring Flashing Patterns CONTROLLER LOCATION CONTROLLER LED RF CMD RPTR CMD RF IDLE RPTR IDLE Scenario 1. Ring Operating Correctly Both Ring Terminals On-long Off-short On-long Off-short On Off All Ring Repeaters On-long Off-short On-long Off-short Off Off Scenario 2. Failed Repeater- RF Path Failure Both Ring Terminals On and Off Same On-short Off-long Off Off Alarmed Ring Repeater Off On and Off Same On Off Off Off All Other Ring Repeaters Scenario 3. Failed Repeater- RPTR Link Failure Both Ring Terminals On and Off Same On-short Off-long Off Off Alarmed Ring Repeater On and Off Same Off Off On Off Off All Other Ring Repeaters Scenario 4. Failed Terminal- RPTR Link Failure Alarmed Ring Terminal On and Off Same No Indication Off On Associated Ring Repeater On and Off Same No Indication Off On Other Ring Terminal On-short Off-long On-short Off-long Off Off All Other Ring Repeaters Depends on Location in Ring Off Off Notes: On-long Off-short duration indicates all ring normal pattern received. On and Off Same duration indicates ring restore pattern received. On-short Off-long duration indicates ring fail pattern received. 2-14 Table 2-2 DS3/OC3 Ring Flashing Patterns CONTROLLER LOCATION CONTROLLER LED RF CMD RPTR CMD RF IDLE RPTR IDLE Ring Repeater – Master Radio On-long Offshort On-long Offshort On Off All Ring Repeaters – Normal Radios On-long Offshort On-long Offshort Off Off Scenario 1. Ring Operating Correctly Scenario 2. Failed Repeater- RF Path Failure Ring Repeater – Master Radio On-short Offlong On-short Offlong Off Off Alarmed Ring Repeater – Normal Radio Off On and Off Same On Off All Other Ring Repeaters – Normal Radio Ring Fail or Ring Restore Ring Fail or Ring Restore Off Off Scenario 3. Failed Repeater- RPTR Link Failure Ring Repeater – Master On-short Offlong On-short Offlong Off Off Alarmed Ring Repeater – Normal Radio On and Off Same Off Off On All Other Ring Repeaters – Normal Radios Ring Fail or Ring Restore Ring Fail or Ring Restore Off Off Scenario 4. Failed Master- RPTR Link Failure Alarmed Ring – Master Radio On-long Offshort Off Off On Associated Ring Repeater – Normal Radio On and Off Same Off Off On All Other Ring Repeaters – Normal Radios Ring Fail or Ring Restore Ring Fail or Ring Restore Off Off Notes: On-long Off-short duration indicates all ring normal pattern received. On and Off Same duration indicates ring restore pattern received. On-short Off-long duration indicates ring fail pattern received. 2-15 ALARM OFF NORM ON 1 POWER OFF 0 RED LED INDICATES INTERNAL FAILURE OR BLOWN FUSE. YELLOW LED INDICATES PA ON/OFF SWITCH IS SET TO OFF. 2-POSITION TOGGLE SWITCH APPLIES POWER TO POWER SUPPLY (ON 1) OR REMOVES POWER (OFF 0). +10.5V +12V FACTORY TEST POINTS FOR POWER SUPPLY VOLTAGES. -5V -12V GND ON PA OFF 2-POSITION TOGGLE SWITCH APPLIES POWER TO PA (IF EQUIPPED) (ON) OR REMOVES POWER (OFF). CAUTION: TIGHTEN MOUNTING SCREWS BEFORE APPLYING POWER 2 PLACES MARKED LMW-7048-sm 06/12/04 Figure 2-7 CE-16BB Power Supply Controls, Indicators, Test Points, and Connectors (Sheet 1 of 2) 2-16 A SPARES 15A FAST BLO PN 264-0928-130 F1 F2 SIDE VIEW OF POWER SUPPLY LMW-3160-sm 08/15/02 Figure 2-7 CE-16BB Power Supply Controls, Indicators, Test Points, and Connectors (Sheet 2 of 2) 2-17 RED LED INDICATES LOSS OF SIGNAL, DETECTION OF BIPOLAR VIOLATION, OR FAILURE OF ACTIVE DS1/E1 LINE(S). GREEN LED INDICATES I/O IN SERVICE. ALM ON LINE I/O RED LED INDICATES XMT SYNC FAILURE BETWEEN I/O INTERFACE MODULES. SYNC ALM ALM ON LINE COMMON LOSS ALM RCV RED LED INDICATES LOSS OF RCV FRAME SYNC. GREEN LED INDICATES RCVR IN SERVICE. RED LED INDICATES FRAME LOSS OR CHANNEL FAIL ALM IN A AND B RCVR CIRCUITS. USUALLY INDICATES FAR-END XMTR ALM. LMW-7051-sm 08/15/02 Figure 2-8 DX-35M DS1 I/O Interface Controls and Indicators 2-18 GREEN LED INDICATES AUXILIARY XMT CIRCUITS ARE ENABLED. ALLOWS TRANSFER OF DATA TO DS1/E1 INTFC CIRCUITS. RED LED INDICATES SERVICE CHANNEL FRAME LOSS DETECTED IN RCV CIRCUITS. GREEN LED INDICATES RCV CIRCUITS ARE ENABLED. ALLOWS TRANSFER OF DATA TO ENCODER/DECODER CIRCUITS. XMT AUX SC ALM RCVR ON RED LED INDICATES RADIO LOSS OF FRAME DETECTED IN RCV CIRCUITS. RAD LOF WYSD DS1 GREEN LED INDICATES WAYSIDE DS1/E1 INTFC CIRCUITS OUTPUT DRIVERS ARE ENABLED. WYSD ALM RED LED INDICATES LOSS OF FRAME DETECTED IN WAYSIDE DS1/E1 INTFC RCV CIRCUIT. RAD DADE 23 456 78 901 POTENTIOMETER ADJUSTS DADE BETWEEN A AND B SYNC PULSES FOR LINE 1 FOR ERRORLESS SWITCHING. DS3 ALIGN 10-POSITION ROTARY SWITCH ADJUSTS DELAY BETWEEN MAIN AND DIVERSITY RCV PATHS IN SPACE DIVERSITY CONFIGURATION. POTENTIOMETER ADJUSTS DADE BETWEEN A AND B SYNC PULSES FOR LINE 2 FOR ERRORLESS SWITCHING. RADIO DADE TEST POINT DS3 ALIGN 1 TEST POINT DS3 ALIGN 2 TEST POINT POTENTIOMETER ADJUSTS DADE BETWEEN A AND B SYNC PULSES FOR LINE 3 FOR ERRORLESS SWITCHING. DS3 ALIGN 3 TEST POINT CHASSIS GROUND TEST POINT LMW-3137-sm 06/12/04 Figure 2-9 DX-35N DS3 I/O Interface Controls and Indicators 2-19 RED LED INDICATES MODULE FAILURE. ALM INSVC WYSD ON WYSD ALM OC3 IN OC3 ALM OC3 OUT GREEN LED INDICATES XMT AND/OR RCV CIRCUITS ARE PASSING DATA. GREEN LED INDICATES WAYSIDE DS1 IN SERVICE. YELLOW LED INDICATES WAYSIDE DS1 SIGNAL FAILURE. GREEN LED INDICATES OC3 DATA ON INPUT TO OPTICAL RCV/RADIO XMT CIRCUITS. YELLOW LED INDICATES OPTICAL RCV CIRCUIT FAILURE. GREEN LED INDICATES OUTPUT LASER IS ON. ON 4-FIBER SYSTEMS, LASERS ON BOTH A AND B I/O INTERFACE ARE ALWAYS ON. ON 2-FIBER SYSTEMS, LASER ON A OR B IS ON. LC OPTICAL CONNECTOR LMW-4011-sm 08/15/02 Figure 2-10 DX-35P OC3 I/O Interface Controls and Indicators 2-20 MONITORS RF OUTPUT DETECTED DC XMT LVL ADJ ADJUSTS RF OUTPUT POWER AT OUTPUT OF XMTR (AND PA, IF EQUIPPED). PWR MON FREQ CONT XMT PWR ALM ADJUSTS FUNDAMENTAL FREQ OF CRYSTAL OSCILLATOR. ON LINE I CARR NULL RED LED INDICATES XMTR POWER LOSS. Q CARR NULL GREEN LED INDICATES XMTR IN SERVICE. TRANSMITTER ADJUSTS I–CHANNEL CARRIER SUPPRESSION. ADJUSTS Q–CHANNEL CARRIER SUPPRESSION. XTAL MON RF MON NULLS RF CARRIER MONITOR POINT TO MEASURE FUNDAMENTAL CRYSTAL FREQ (MHz) (BNC, FEMALE). MONITOR POINT TO MEASURE XMT OUTPUT SIGNAL LEVEL (SMA, FEMALE). RF OUT RF OUTPUT CONNECTOR (SMA, FEMALE). MW211-0017-1 03/29/03 Figure 2-11 UD-35( ) Transmitter Controls, Indicators, Test Points, and Connectors 2-21 RED LED INDICATES LOSS OF LOCK FROM RECEIVE SIGNAL. YELLOW LED INDICATES DEGRADED RECEIVE SIGNAL. GREEN LED INDICATES RCVR IN SERVICE. CHAN ALM EYE CLOSURE ON LINE PED AFC NORM AFC MON 2-POSITION TOGGLE SWITCH SETS AFC TO NORMAL (NORM) OR PEDESTAL (PED). NORM POSITION LOCKS RCVR TO FAR-END XMTR. RX (AFC MON) VOLTAGE DISPLAYED ON ANALOG MONITOR SCREEN TRACKS AFC VOLTAGE. PED POSITION DISABLES AFC AND LOCKS RCVR TO FIXED VOLTAGE (SETS RCV LO ON FREQ WITHOUT PHASE LOCK). EYE MON RSL MON GND FREQ CONT RECEIVER MONITOR POINT TO MEASURE DC CONTROL VOLTAGE USED TO CONTROL LO FREQ. SAME VOLTAGE IS DISPLAYED ON RX (AFC MON) FIELD ON ANALOG MONITOR SCREEN. MONITOR POINT TO MEASURE DC VOLTAGE INDICATING QUALITY OF RECEIVE BASEBAND SIGNALS. SAME VOLTAGE IS DISPLAYED ON RX (EYE MON) FIELD ON ANALOG MONITOR SCREEN. MONITOR POINT TO MEASURE DC VOLTAGE PROPORTIONAL TO RSL. SAME VOLTAGE IS DISPLAYED ON RX (RSL MON) FIELD ON ANALOG MONITOR SCREEN. XTAL MON RF IN ADJUSTS FREQ OF CRYSTAL OSCILLATOR. ONLY WITH AFC PED/NORM SWITCH IN PED POSITION. MONITOR POINT TO MEASURE FUNDAMENTAL CRYSTAL FREQ (MHz) (BNC, FEMALE). RF INPUT CONNECTOR (SMA, FEMALE). LMW-6089-sm 08/15/02 Figure 2-12 DS1/E1 UD-36( ) Receiver (Obsolete Version With Pedestal Switch) Controls, Indicators, Test Points, and Connectors 2-22 RED LED INDICATES LOSS OF LOCK FROM RECEIVE SIGNAL. YELLOW LED INDICATES DEGRADED RECEIVE SIGNAL. CHAN ALM EYE CLOSURE GREEN LED INDICATES RCVR IN SERVICE. ON LINE AFC MON EYE MON RSL MON GND RECEIVER MONITOR POINT TO MEASURE DC CONTROL VOLTAGE USED TO CONTROL LO FREQ. SAME VOLTAGE IS DISPLAYED ON RX (AFC MON) FIELD ON ANALOG MONITOR SCREEN. MONITOR POINT TO MEASURE DC VOLTAGE INDICATING QUALITY OF RECEIVE BASEBAND SIGNALS. SAME VOLTAGE IS DISPLAYED ON RX (EYE MON) FIELD ON ANALOG MONITOR SCREEN. MONITOR POINT TO MEASURE DC VOLTAGE PROPORTIONAL TO RSL. SAME VOLTAGE IS DISPLAYED AS DBM ON RX (RSL 1) dBm FIELD ON ANALOG MONITOR SCREEN. XTAL MON RF IN MONITOR POINT TO MEASURE FREQ RCVR IS LOCKING ON (RCVR LOCKS ON XTAL FREQ OF ASSOCIATED UPSTREAM XMTR) (BNC, FEMALE). RF INPUT CONNECTOR (SMA, FEMALE). LMW-3171-sm 06/12/04 Figure 2-13 UD-36( ) DS1/E1/DS3/OC3 Single Receiver Controls, Indicators, Test Points, and Connectors 2-23 RED LED INDICATES LOSS OF LOCK ON MAIN RECEIVE SIGNAL. RED LED INDICATES LOSS OF LOCK ON DIVERSITY RECEIVE SIGNAL. YELLOW LED INDICATES DEGRADED MAIN RECEIVE SIGNAL. YELLOW LED INDICATES DEGRADED DIVERSITY RECEIVE SIGNAL. MN DV CHANNEL ALM GREEN LED INDICATES MAIN RCVR IN SERVICE. GREEN LED INDICATES DIVERSITY RCVR IN SERVICE. EYE CLOSURE ON LINE MONITOR POINT TO MEASURE DC CONTROL VOLTAGE USED TO CONTROL MAIN LO FREQ. M AFC I EYE N RSL MONITOR POINT TO MEASURE DC VOLTAGE INDICATING QUALITY OF MAIN RECEIVE BASEBAND SIGNALS. SAME VOLTAGE IS DISPLAYED ON RX (EYE MON) (MN) FIELD ON ANALOG MONITOR SCREEN. AFC V EYE R RSL I MONITOR POINT TO MEASURE DC VOLTAGE PROPORTIONAL TO MAIN RSL. SAME VOLTAGE IS CONVERTED TO dBm, AND dBm LEVEL IS DISPLAYED IN RX (RSL) (MN) FIELD ON ANALOG MONITOR SCREEN. MONITOR POINT TO MEASURE DC VOLTAGE INDICATING QUALITY OF DIVERSITY RECEIVE BASEBAND SIGNALS. SAME VOLTAGE IS DISPLAYED ON RX (EYE MON) (DV) FIELD ON ANALOG MONITOR SCREEN. XTAL DV RF IN MN MONITOR POINT TO MEASURE DC CONTROL VOLTAGE USED TO CONTROL DIVERSITY LO FREQ. RF IN DV XTAL MN GND MAIN RF INPUT CABLE (SMA FEMALE) MONITOR POINT TO MEASURE DC VOLTAGE PROPORTIONAL TO DIVERSITY RSL. SAME VOLTAGE IS CONVERTED TO dBm, AND dBm LEVEL IS DISPLAYED IN RX (RSL) (DV) FIELD ON ANALOG MONITOR SCREEN. DIVERSITY RF INPUT CABLE (SMA FEMALE) DUAL RECEIVER MONITOR POINT TO MEASURE MAIN FUNDAMENTAL CRYSTAL FREQ (MHz) (SMA FEMALE) FACTORY USE CONNECTOR MONITOR POINT TO MEASURE DIVERSITY FUNDAMENTAL CRYSTAL FREQ (MHz) (SMA FEMALE) TEST GROUND POINT LMW-9033-sm 06/12/04 Figure 2-14 UD 36( ) Dual Receiver Controls & Indicators, Test Points and Connectors 2-24 MONITOR POINT TO MEASURE DC VOLTAGE REPRESENTATIVE OF OUPUT POWER (0.1V DC PER DB OF RF OUTPUT SIGNAL FOR NOMINAL POWER ONLY) DC MON GND RED LED INDICATES RF PWR IS ABOVE OR BELOW ALARM THRESHOLD SET BY PWR ALM ADJ. PWR ALM TEMP ALM YELLOW LED INDICATES HIGH TEMP ON PA (MAY BE CAUSED BY IMPROPER MOUNTING TO HEATSINK). DC MON ADJ PWR ALM ADJ ALLOWS USER TO ADJUST VOLTAGE AT DC MON TEST POINT (0.1V DC PER DB OF RF OUTPUT SIGNAL IS TYPICAL) 10.5V DC FACTORY ADJUST ONLY POWER AMPLIFIER MONITOR POINT TO MEASURE 10.5V DC INPUT RF MON RF IN MONITOR POINT TO MEASURE/CALIBRATE RF OUTPUT SIGNAL AT TOP OF STACK (SMA, FEMALE) (APPROX. 30 DB DOWN FROM RF OUTPUT) RF INPUT CABLE (SMA MALE) MW211-0038-1-sm 04/29/03 Figure 2-15 UD-51( ) Power Amplifier Controls, Indicators, Test Points, and Connectors 2-25 FRONT VIEW FV/DC SWITCH SET TO FV FOR MDR-8000 APPLICATION NOT USED NOT USED BIS BUTTON - PRESS TO CALL LAST NUMBER DIALED ON-HOOK/OFF-HOOK SWITCH - PUSH FROM LEFT TO RIGHT TO TALK AND LISTEN REAR VIEW RJ11 CONNECTOR RJ11 CONNECTOR OFF-HOOK INDICATOR LMW-3006-sm 8/15/02 Figure 2-16 Handset Controls, Indicators, Test Points, and Connectors 2-26 3 INTERCONNECT SECTION INTRODUCTION This section gives the location and describes strapping, power connections, signal connections, status and alarm connections, and service channel connections. For further details, refer to the complete instruction book on the attached CD ROM. 3.1 INSTALL POWER CABLE ASSEMBLIES See Figure 3-1 for power cable assembly installation procedures. The MDR-8000 is internally wired to accept 20.5 to 60 V dc input power with positive or negative ground. To protect maintenance personnel from lightning strikes, the ground system must be integrated by bonding station ground and dc battery return together. The dc power connectors J1 and J2 are located on the rear of the back panel. Install power cables as shown. 3.2 DANGER Possibility of Injury to Personnel Short circuiting low-voltage, low-impedance dc circuits can cause arcing that may result in burns or eye injury. Remove rings, watches, and other metal jewelry while working with primary circuits. Exercise caution to avoid shorting input power terminals. DANGER Possibility of Injury to Personnel To protect maintenance personnel from antenna tower lightning strikes, the ground system must be integrated by bonding frame ground and dc battery return together. WARNING Possibility of Damage to Equipment Do not apply battery power until it is determined that A and B battery cables with isolated returns and power cables are wired correctly. With power applied, reverse polarity on wiring (+batt wired to -batt pin on connector) can cause power supply fuse to blow. 3-1 Note Grounding of pole, antenna, customer interfaces, and all entrances to the building interior shall meet local electrical code and standard business practices. 1. DETERMINE IF INSTALLATION REQUIRES POS OR NEG GND. PIN 1 POS 2. INSTALL BATT, GND, AND JUMPER WIRES ON PWR CABLE ASSEMBLY. PIN 3 NEG PIN 2 GND 3. CONNECT PWR CABLE ASSEMBLY TO J1 (AND J2 IF HOT-STBY). 4. CONNECT RACK GND AND CHASSIS GND. J1 (J2 ON OPPOSITE END OF SHELF) 5. CONNECT BATT. REAR VIEW OF SHELF PWR CABLE ASSEMBLY PN 695-7845-005/009 RED ORN SLIDE-ON LUG BLK CONNECT + BATT WIRE TO + RACK GND FOR POS GND INSTALLATIONS ORN 12 AWG CONNECT – BATT WIRE TO – RACK GND FOR NEG GND INSTALLATIONS BLK 12 AWG + BATT RED 12 AWG CHASSIS GND – BATT Figure 3-1 Power Cable Assembly Installation 3-2 LMW-3103-sm 03/25/03 3.3 PDU STRAPPING AND CONNECTIONS BATTERY INPUT WIRE SIZE NO. 4 (MAX) – A BATT – B BATT TOP VIEW POWER DISTRIBUTION PANEL FRONT VIEW – PANEL REMOVED NEG POS 'A' BATTERY 'A' BATTERY -24/-48 +24/+48 NEG POS 'B' BATTERY 'B' BATTERY -24/-48 +24/+48 R3 TB1 TB2 TB3 TB4 E7 E15 E1 E3 E4 E6 E8 2C 2B E2 STRAP E7 TO E15 FOR POSITIVE INPUT VOLTAGE. STRAP E8 TO E15 FOR NEGATIVE INPUT VOLTAGE. E5 2D 2A STRAP J2D TO J2C TO J2B FOR 24V OPERATION. STRAP J2A TO J2B TO J2D FOR 48V OPERATION. CIRCUIT BOARD LOCATED INSIDE POWER DISTRIBUTION PANEL FRONT VIEW JUMPER E2 TO E3 AND E5 TO E6 FOR POSITIVE RACK GND. JUMPER E1 TO E2 AND E4 TO E5 FOR NEGATIVE RACK GND. ALSO, MOVE CHASSIS GND TO AGREE WITH RACK GND POLARITY. SEE FIGURE 3-1, POWER CABLE ASSEMBLY INSTALLATION, AND APPLICATION DWG 3DH031770000 EJZZA. LMW-7029-sm 07/12/02 rev 03/25/03 Figure 3-2 PDU (695-6200-001/002) Strapping and Connections (Sheet 1 of 2) 3-3 BATTERY INPUT WIRE SIZE NO. 4 (MAX) POWER DISTRIBUTION UNIT ISOMETRIC VIEW – CIRCUIT BOARD AND FRONT PANEL REMOVED A+ A- BATTERY B+ B- BATTERY BATTERY E38 E39 FUSES 3 4 5 FUSESFUSES 35 4 3 2 FUSES 4 3 2 E37 E42 E1 E2 E3 E4 E5 E6 E7 E2 E3 4 E15 E16 E17 E18 BATTERY E40 E41 E19 E20 E21 E22 E23 E24 CIRCUIT BOARD LOCATED INSIDE PDU JUMPER E39 TO E38 AND E42 TO E41 FOR POSITIVE RACK GND (AS SHOWN ABOVE). JUMPER E37 TO E38 AND E40 TO E41 FOR NEGATIVE RACK GND. FOR DETAILED WIRING INFORMATION, SEE APPLICATION DWG 3DH031770000 EJZZA. Figure 3-2 PDU (3EM13317AA) Strapping and Connections (Sheet 2 of 2) 3-4 LMW-9001 04/22/03 3.4 SHELF/RACK ALARM CONNECTION Each MDR-8000 rack equipped with the Power Distribution Unit (PDU) 695-6200-001/002 has a visual rack alarm indicator to report a shelf failure. In order to activate a rack alarm visual indicator on the PDU, the shelf alarm output from each MDR-8000 shelf must be hardwired to connector J1 on the PDU. The shelf alarm is provided on alarm connector J305 pin 24 (major/visual alarm). A wire-wrap adapter (PN 695-4171-002) for connector J305 is available. Insulated 22-gauge solid copper wire is recommended for connecting to the wire-wrap adapter. To attach to J1 (2-pin connector) on the PDU, use 2-position socket housing PN 372-0114-140 and socket contact PN 372-0114-390. See Figure 3-3, sheet 1, for shelf-to-rack alarm wiring. Each MDR-8000 rack equipped with PDU 3EM13317AA has a blown fuse alarm visual indicator and a Form C relay alarm output (J4, J5, and J6) for connection to customer alarm equipment. An optional Fuse and Shelf alarm plug-in assembly is available to provide shelf alarm connections requiring Form C relays. The alarm inputs (major and minor) must be hard wired to J3 on the PDU. The alarms are provided on alarm connector J305 pin 24 (major/visual alarm) and pin 50 (minor/audible alarm) of each shelf. A wire-wrap adapter (PN 695-4171-002) for connector J305 is available. Insulated 22-gauge solid copper wire is recommended for connecting to the wire-wrap adapter and also to J3 on the PDU. Alarm outputs are transmitted to customer equipment via Form C relay outputs (J4, J5, J6, relays 1 through 8). This option also includes the blown fuse alarm indicator and Form C relay alarm output (J4, J5, and J6 – relay 9). See Figure 3-3, sheet 2, for shelf to PDU alarm wiring. 3-5 E15 R1 R2 E31 E33 F4 E30 E32 E7 TO ATTACH USE: 2 - POSITION SOCKET HOUSING: PN 372-0114-140 AND SOCKET CONTACT: PN 372-0114-390 E8 E34 E4 E5 J2C J2B ABAM CABLE PN 424-0429-030 J2D J2A WIRE WRAP ADAPTER (PN 695-4171-002) 24 MAJOR / VISUAL ALM PIN 1 PDU MDR-8000 SHELF J305 24 MAJOR / VISUAL ALM FAN ASSY HEAT DEFLECTOR MDR-8000 SHELF J305 FAN ASSY LMW-7070-sm 07/24/02 Figure 3-3 Shelf Alarm Wiring PDU (695-6200-001/002) (Sheet 1 of 2) 3-6 RACK GND 20 AMP 20 AMP 20 AMP 10 AMP FUSES E13 E14 E15 E16 E17 E18 1 AMP E25 E26 E27 E28 E29 E30 20 AMP 10 AMP E7 E8 E9 E10 E11 E12 10 AMP 1 AMP 1 AMP 1 AMP 10 AMP 20 AMP FUSES 20 AMP 20 AMP 20 AMP FUSE ALARM INDICATOR E31 E32 E33 E34 E35 E36 RACK GND WIRE WRAP ALARM INPUT J3 ALARM OUTPUT J4 J5 J6 MAJOR 1 MINOR 1 MAJOR 2 MINOR 2 MAJOR 3 MINOR 3 MAJOR 4/AUX MINOR 4/AUX UNUSED CUSTOMER OUTPUTS FUSE ALM NC COM NO PIN 1 24 PDU MDR-8000 SHELF J305 WIRE WRAP ADAPTER 50 24 PIN 1 FAN ASSY HEAT DEFLECTOR MDR-8000 SHELF J305 50 FAN ASSY LMW-8057-SM 04/23/03 Figure 3-3 Shelf Alarm Wiring PDU (3EM13317AA) (Sheet 2 of 2) 3-7 3.5 DS1 CONNECTIONS (J303 IN AND J304 OUT) Recommended connectorized cable assembly – PN 695-7806-001 through -005 (22 AWG 16 pair shielded, jacketed cable with 37-pin D-type connector on one end). See Figure 3-4 for shelf connector location and pinout. Refer to Table 3-1 for mating cable wiring and color code. LBO J303/J304 19 37 20 FRONT VIEW LMW-9037 05/29/03 Figure 3-4 DS1 Connectors Location and Pinout 3-8 Table 3-1 DS1 IN J303 and DS1 OUT J304 Pinout Assignments CONNECTOR PIN NUMBER WIRE COLOR SIGNAL NAME CABLE PAIR NUMBER WHITE–BLUE CHAN 1 TIP 20 BLUE–WHITE CHAN 1 RING WHITE–ORANGE CHAN 2 TIP 21 ORANGE–WHITE CHAN 2 RING WHITE–GREEN CHAN 3 TIP 22 GREEN–WHITE CHAN 3 RING WHITE–BROWN CHAN 4 TIP 23 BROWN–WHITE CHAN 4 RING WHITE–SLATE CHAN 5 TIP 24 SLATE–WHITE CHAN 5 RING RED–BLUE CHAN 6 TIP 25 BLUE–RED CHAN 6 RING RED–ORANGE CHAN 7 TIP 26 ORANGE–RED CHAN 7 RING RED–GREEN CHAN 8 TIP 27 GREEN–RED CHAN 8 RING RED–BROWN CHAN 9 TIP 28 BROWN–RED CHAN 9 RING 10 RED–SLATE CHAN 10 TIP 29 SLATE–RED CHAN 10 RING 11 BLACK–BLUE CHAN 11 TIP 30 BLUE–BLACK CHAN 11 RING 12 BLACK–ORANGE CHAN 12 TIP 31 ORANGE–BLACK CHAN 12 RING 13 BLACK–GREEN CHAN 13 TIP 32 GREEN–BLACK CHAN 13 RING 14 BLACK–BROWN CHAN 14 TIP 33 BROWN–BLACK CHAN 14 RING 15 BLACK–SLATE CHAN 15 TIP 34 SLATE–BLACK CHAN 15 RING 16 YELLOW–BLUE CHAN 16 TIP 35 BLUE–YELLOW CHAN 16 RING 10 11 12 13 14 15 16 3-9 3.6 DS1 REPEATER (J314 ON ONE SHELF TO J314 ON SECOND SHELF) Note The DS1 repeater cable carries clocks, DS1 data, and overhead for two directions. If the 314 cable is not used, the embedded data in the overhead must be cabled individually. In this case, individual cables must be run for MCS–11, audio, RS-232, and ELMC. Recommended connectorized cable assembly – PN 695-7836-001/005 (25 pair shielded cable with 50 pin Amp connectors) (SCSI). See Figure 3-5 for shelf connector location and pinout. Refer to the Interconnect Section on attached CD for mating cable wiring and color code. Note Use repeater cables for cabling repeater shelf 1 to repeater shelf 2 (eastbound/westbound data/clock) LBO 25 J314 26 50 FRONT VIEW Figure 3-5 Connector J314 Location – DS1 LBO 3-10 PIN 1 LMW-9038 05/29/03 DS3 LBO STRAPPING AND CONNECTIONS The DS3 LBO compensates for the distance to the cross-connect for DS3 and wayside DS1 outputs. See Figure 3-6 for strap locations. Refer to Table 3-2 for strapping requirements. 3.7 IN/OUT STRAPPING FOR WAYSIDE DS1 LINES IN IN IN/OUT STRAPPING FOR DS3 LINES LBO LBO OUT IN OUT LBO IN OUT LBO OUT DS3 LINE 1 WAYSIDE LINE 1 DS3 LINE 2 DS3 LINE 3 LMW-3149B-sm 07/27/02 WAYSIDE LINE 2 WAYSIDE LINE 3 Figure 3-6 DS3 LBO Strapping Note When using 734 or equivalent type DS3 cable, 450 feet is the maximum length to the cross-connect. The maximum length with the LBO strapped IN is 225 feet. Table 3-2 DS3 LBO Strapping OUTPUTS DISTANCE TO CROSS-CONNECT STRAPPING DS3 0 to 225 ft In DS3 226 to 450 ft Out Wayside DS1 0 to 330 ft In Wayside DS1 331 to 660 ft Out 3-11 3.8 DS3 LBO DS3 BNC CONNECTIONS (J21 THROUGH J26) BNC removal tool (PN 359-0092-010) is required for installing and removing BNC cables. J301 Recommended connectorized cable assembly for all applications except repeaters, PN 6324429-096/180 (8/15 ft RG-59B/U coax cable with straight male BNC connector on one end and right angle male BNC connector on other end). For repeater applications, recommend PN 632-4288-096/180 (8/15 ft RG-59B/U coax cable with straight male BNC connector on each end). See Figure 3-7 for locations. Refer to Table 3-3 for connections. J307 J315 J313 J308 J309 J305 J318 J310 J312 J316 J317 J302 LMW-7065-sm 07/23/02 LINE 1 OUT – J21 J22 – LINE 1 IN LINE 2 OUT – J23 J24 – LINE 2 IN LINE 3 OUT – J25 J26 – LINE 3 IN FRONT VIEW Figure 3-7 DS3 LBO DS3 Connectors Location 3-12 Table 3-3 DS3 LBO Connectors DS3 INPUTS DS3 OUTPUTS FUNCTION BNC CONNECTOR FUNCTION BNC CONNECTOR DS3 LINE 1 J22 DS3 LINE 1 J21 DS3 LINE 2 J24 DS3 LINE 2 J23 DS3 LINE 3 J26 DS3 LINE 3 J25 DS3 LBO WAYSIDE DS1 CONNECTIONS (J201 IN AND J202 OUT) Wayside DS1 is an option in the MDR-8000 DS3 radios. This option provides 1 DS1 for each equipped DS3. To activate the wayside channels requires a small circuit board, called ELMC option key, that plugs onto the controller module. The protection of the wayside channels follows the protection scheme of the radio configuration. In other words, if the radio is hot-standby the wayside channels are hot-standby. The channels are point to point just as is the payload traffic. They are independent of the traffic and reside in the overhead channels. The advantage of the wayside DS1 is the ability to drop 1 to 3 DS1’s without having to add a 1:3 muldem to access the traffic. Refer to Table 3-4 for ELMC option key requirements for remote monitoring/controlling wayside DS1s. 3.9 Table 3-4 Wayside DS1 Performance and Control PART NO. FUNCTION ELMC Option Key 695-5647-019 Required to enable WS DS1 lines for remote wayside DS1status ELMC Option Key 695-5647-020 Required to enable WS DS1 lines for remote wayside DS1status + remote provisioning and downloading 3-13 3.9.1 Wayside DS1 Terminal J301 Recommended connectorized cable assembly – PN 695-4125-041 (26 AWG 5 pair shielded, jacketed cable with 9-pin D-type connector on one end). See Figure 3-8 for shelf connector location and pinout. Refer to Interconnect section on attached CD for mating cable wiring and color code. J307 J315 J313 J308 J318 J309 J310 J305 J312 J316 J317 J302 LMW-7069 07/23/02 LINE 3 OUT TIP LINE 3 IN TIP GND GND J201 INPUT LINE 2 IN TIP LINE 1 IN TIP J202 OUTPUT LINE 2 OUT TIP LINE 1 OUT TIP LINE 1 IN RING LINE 1 OUT RING LINE 2 IN RING LINE 2 OUT RING LINE 3 IN RING LINE 3 OUT RING FRONT VIEW FRONT VIEW Figure 3-8 DS3 LBO Wayside DS1 Connectors Location and Pinout 3-14 3.9.2 Wayside DS1 Repeater Recommended connectorized cable assembly – PN 695-4125-051 (26 AWG 5 pair shielded, jacketed cable with 9-pin D-type connector on each end). See Figure 3-9 for Wayside DS1 repeater interconnect. SHELF 1 SHELF 2 OUTPUT J202 J202 OUTPUT INPUT J201 J201 INPUT LMW-7071-sm 7/24/02 Figure 3-9 Wayside DS1 Repeater Interconnect 3.10 DS3 REPEATER (J401 ON ONE SHELF TO J401 ON SECOND SHELF) Note The DS3 repeater cable carries clocks, data, and overhead for two directions. It does not carry DS3 or wayside DS1 traffic. DS3 and wayside DS1 cables must be run separately. If the 401 cable is not used, the embedded data in the overhead must be cabled individually. In this case, individual cables must be run for MCS-11, audio, RS-232, and ELMC. Recommended connectorized cable assembly – PN 695-7836-001/005 (25 pair shielded cable with 50 pin Amp connectors) (SCSI). See Figure 3-10 for shelf connector location and pinout. Refer to Interconnect section on attached CD for mating cable wiring and color code. Note Use repeater cables for cabling repeater shelf 1 to repeater shelf 2 (eastbound/westbound data/clock) 3-15 J301 J307 J315 J313 J308 J318 J309 J305 J310 J312 J316 J317 J302 LMW-7066-sm 07/23/02 J401 25 PIN 1 26 50 FRONT VIEW Figure 3-10 Connector J401 Location – DS3 LBO 3.11 FIBER OPTIC CABLE CONNECTIONS DANGER Possibility of Injury to Personnel This system normally operates as a Class I Laser Product (no hazard), however during servicing operations, when optical connectors are being connected, disconnected, or handled without dust covers, it is possible to be exposed to Class IIIB laser radiation which can cause eye damage. 3-16 WARNING Possibility of Damage to Equipment Fiber optic connectors are delicate and can be damaged easily by dirt or debris on the end of the connector. Keep fiber optic connectors free of dust and debris by cleaning the connector before and after use. Carefully clean the fiber optic connector and cable ends with a cotton swab dipped in alcohol or an alcohol wipe. Keep safety cap on connectors when not in use. The Alcatel 2 or 4 fiber management panel (PN 3EM09257AB) and 2x4 fiber management panel (PN 3EM09257AA) connections are described. For other fiber management equipment, refer to the manufacturers instructions. See Figure 3-11 and Figure 3-12 for typical connections. Refer to Table 3-5 for recommended fiber optic jumpers. Table 3-5 Fiber Optic Jumpers JUMPER TYPE PART NO. APPLICATION FC to LC 3EM07651AA-AK TERMINAL SC TO LC 3EM07646AA-AK TERMINAL LC TO LC 3EM07641AA-AK REPEATER 3.11.1 2 or 4 Fiber Management Panel The 2 or 4 fiber management panel provides a direct interface with customers 2 or 4 fiber equipment. The two fibers on a non-standby radio or four fibers on a hot-standby radio connect to the two or four fibers from the customers equipment. The 2 or 4 fiber configuration requires the duplex adapter panel to route the fiber to/from the I/O interface modules. One duplex adapter panel can accommodate two radio shelves. Customer fiber must have SC type connectors 3.11.2 2x4 Fiber Switched Management Panel The 2x4 fiber management panel interfaces the four fibers on a hot-standby shelf with customer’s 2-fiber equipment. The 2x4 fiber configuration requires combiner/splitter units to route the fiber to/from the I/O interface modules. One combiner/splitter unit per radio shelf is required. The 2x4-fiber management panel has cutouts for two combiner/splitter units and can accommodate two radio shelves. 3-17 VIEW OF CONNECTOR WITH FIBER OPTIC CABLES REMOVED IN OT-1 OR-1 CONNECT OPTICAL RCV (OR) CABLE TO IN CONNECTOR OUT CONNECT OPTICAL XMT (OT) CABLE TO OUT CONNECTOR CUSTOMER INTFC SIDE VIEW OT-3 OUT OT-4 OUT IN R- IN R- IN RO OT-2 OUT OT-1 OUT Figure 3-11 2 or 4 Fiber Management Panel 3-18 IN I/O INTFC MODULE SIDE VIEW OT-1 OUT OT-2 OUT SHELF 2B OUTPUTS SHELF 2A INPUTS SHELF 1B SHELF 1A R- IN R- IN R- IN RO R- IN LMW-6038 07/22/02 OT-4 OUT OT-3 OUT VIEW OF CONNECTOR WITH FIBER OPTIC CABLES REMOVED IN OT-1 OR-1 CONNECT OPTICAL RCV (OR) CABLE TO IN CONNECTOR OUT CONNECT OPTICAL XMT (OT) CABLE TO OUT CONNECTOR FRONT VIEW COM COM OT-1 OT-2 FROM RADIO I/O INTFC MODULES OUTPUT TO CUSTOMER 2 FIBER COM SPLITTER COM COMBINER LMW-6037-sm 07/22/02 OR-1 OR-2 TO RADIO I/O INTFC MODULES INPUT FROM CUSTOMER 2 FIBER Figure 3-12 2x4 Fiber Management Panel 3-19 3.12 OC3 AUX INTERFACE BOARD WAYSIDE DS1 CONNECTIONS (J201 IN AND J202 OUT) Wayside DS1 is an option in the MDR-8000 OC3 radios that prevents having to add a SONET add/drop MUX to access payload traffic. This option provides 1 DS1 for each STS-1 within the OC3. Refer to Table 3-4 for ELMC option key requirements for remote monitoring/controlling wayside DS1. 3.12.1 Wayside DS1 Terminal Recommended connectorized cable assembly – PN 695-4125-041 (26 AWG 5 pair shielded, jacketed cable with 9-pin D-type connector on one end). See Figure 3-13 for location. Refer to Interconnect section on attached CD for pinout and color code. 3.12.2 Wayside DS1 Repeater J301 Recommended connectorized cable assembly – PN 695-4125-051 (26 AWG 5 pair shielded, jacketed cable with 9-pin D-type connector on each end). See Figure 3-9 for Wayside DS1 repeater interconnect. J307 J315 J313 J308 J318 J309 J310 J305 J312 J316 J317 J302 LMW-7068-sm 07/23/02 LINE 3 IN TIP LINE 3 OUT TIP GND LINE 2 IN TIP J201 INPUT LINE 1 IN TIP GND LINE 2 OUT TIP J202 OUTPUT LINE 1 OUT TIP LINE 1 IN RING LINE 1 OUT RING LINE 2 IN RING LINE 2 OUT RING LINE 3 IN RING LINE 3 OUT RING FRONT VIEW FRONT VIEW Figure 3-13 Wayside DS1 Connectors – OC3 AUX Interface 3-20 3.13 OC3 REPEATER (J203 ON ONE SHELF TO J203 ON SECOND SHELF) Note The OC3 radio repeater cable carries clocks, data, and overhead for two directions. It does not carry OC3 or Wayside DS1 traffic. OC3 fiber optic cables and Wayside DS1 cables must be run separately. If the repeater cable is not used, the embedded data in the overhead must be cabled individually. In this case, separate cables must be run for MCS11, audio, RS-232, and ELMC. Recommended connectorized cable assembly – PN 695-4125-007/013 (26 AWG 5 pair shielded, jacketed cable). See Figure 3-14 for shelf connector location and pinout. Refer to Interconnect section on attached CD for mating cable wiring and color code. Note J301 Use repeater cables for cabling repeater shelf 1 to repeater shelf 2 (eastbound/westbound data/clock) J307 J315 J313 J308 J309 J305 J318 J310 J312 J316 J317 J302 LMW-7067 07/23/02 GND RPTR DS1 OUT TIP J203 RPTR DS1 IN TIP RPTR DS1 IN RING RPTR DS1 OUT RING FRONT VIEW Figure 3-14 Repeater Connector – OC3 AUX Interface 3-21 J301 3.14 USI/CONTROLLER CABLE CONNECTION TO LAPTOP (J301) Recommended connectorized cable assembly – PN 695-7848-001 through 004 (24 AWG 6 pair shielded, jacketed cable with DEMM-9P connector on each end). See Figure 3-15 for controller connector location and pinout. Refer to attached CD for mating cable pinout and color code. J307 J315 J313 J308 J309 J305 J318 J310 J312 J316 J317 J302 LMW-7059 02/04/03 USI DSR RTS CTS RI DCD RxD TxD DTR GND J301 FRONT VIEW Figure 3-15 Controller USI Connector Location and Pinout 3.15 SERVICE CHANNEL A service channel is defined as a non-revenue bearing channel provided as part of a transmission system for operation, maintenance, monitoring, and control of the system. The MDR-8000 provides a 256 kb/s auxiliary channel for servicing the radio. This is an overhead channel and is independent of the traffic channels. The 256 kb/s service channel contains four 64 kb/s service channels. Three of the four 64 kb/s channels (Service Channel 1, 2, and 3) can be provisioned on the USI for a specific use. Service channel 0 is dedicated to radio commands and ELMC. Service channel 0 is not provisionable. The four channels are multiplexed and shifted in and out of registers on the controller. 3-22 See Figure 3-16. There are eight connectors on the backplane to interface with three of the service channels. The connectors on the backplane interface three functions: audio, RS232, and MCS-11. Each service channel is provisioned for a specific function. As shown by the vertical line connecting to the three functions on one side and the three service channels (SC1, SC2, and SC3) on the opposite side, audio and MCS can be put on any open service channel. RS-232 data can be put on service channel 1 or 2 but cannot be put on service channel 3. This is shown by the dashed lines to the specific service channel. 3.15.1 Handset Jack The 2-wire port at the TEL connector on AE-37Y Controller accepts either the optional handset or a standard telephone. The 2-wire port is not provisionable. To use the handset, the radio must be provisioned for Audio 1. J316 AUDIO TELEPHONE (4-WIRE) J317 RADIO CONTROLLER CONTROLLER SC1 AUDIO TSM–2500 RADIO J307, J310 (BRIDGED) MCS J316 AUDIO AUDIO SC MULDEM SC2 SC2 OVERHEAD CHANNELS OVERHEAD CHANNELS SC3 SC3 TEL J307, J310 (BRIDGED) TSM–2500 MCS TEL J315, J318 (BRIDGED) J315, J318 (BRIDGED) SC0 ELMC J317 SC1 SC MULDEM TELEPHONE (4-WIRE) SC0 ELMC J312 J312 RS232–1 LAPTOP HANDSET (2-WIRE) RS232–1 LAPTOP J313 J313 RS232–2 RS232–2 LMW-3138 04/21/04 Figure 3-16 Service Channel Connections/Applications 3-23 3.15.2 Service Channels Provisioning Options Note Service channels at both ends of a hop (and end-to-end in a link) must be provisioned the same. Service channel provisioning is interactive. When an option is selected for any service channel, that option is excluded from selections on the other applicable service channels. Provisioning options for Service Channels 1, 2, and 3 are listed: • Service Channel 1 (64 kb/s channel) – can be used to carry 4-wire audio, RS-232 data, or MCS-11 fault alarm information. • AUDIO 1 and 2 – Two audio provisioning options (AUDIO 1 and AUDIO 2) are provided for Service Channel 1. Each audio channel is a 4-wire audio channel that provides off-hook detection, level control, and E and M-lead signaling. AUDIO 1 also has DTMF decoding that allows a specific station to be dialed. External connection to AUDIO 1 is J316. External connection to AUDIO 2 is J317. • RS-232-1 – RS-232 Channel 1 is an RS-232 formatted data channel that can provide interface to an external computer/modem. External connection to RS-232-1 is J312. • MCS-11 – The MCS-11 channel is an RS-422 formatted data that provides an interface to an external MCS-11 Monitor and Control System or TSM system (used to control multiple MCS-11 systems). External connections to the MCS-11 include J307, J308, J309 and J310. • Service channel 2 (64 kb/s channel) – can be used to carry 4-wire audio, RS-232 data, or MCS-11 fault alarm information. • AUDIO-1 and -2 – Same as Service Channel 1 • RS-232-2 – RS-232 Channel 2 is an RS-232 formatted data channel that can provide interface to an external computer/modem. External connection to RS-232-2 is J313. • MCS-11 – Same as Service Channel 1 • Service Channel 3 (64 kb/s channel) – can be used to carry 4-wire audio, or MCS-11 fault alarm information • AUDIO 1 and 2 – Same as Service Channel 1 • MCS-11 – Same as Service Channel 1. 3.15.3 Audio 1, Audio 2 (J316, J317) The Audio 1 and 2 4-wire functions are provisionable. Refer to the Initial Turnup section for details. These audio functions should not be confused with the non-provisionable 2-wire handset. 3-24 Audio 1 Audio 1 (J316) is a 4-wire function port on the backplane that provides off-hook detection, level control, E and M-lead signaling, DTMF, and 2-wire handset capabilities. Audio 2 Audio 2 (J317) is a 4-wire function port on the backplane that provides off-hook detection, level control, and E and M-lead signaling. Audio 2 has no DTMF decoding capabilities. Recommended connectorized cable assembly – PN 695-4125-026 through 030 (26 AWG 5 pair shielded, jacketed cable with 9-pin D-type connector on each end). See Figure 3-17 for shelf connector locations and pinout. Refer to Table 3-6 for mating cable wiring and color code. or J301 Recommended cable – PN 424-0305-030 (26 AWG 5 pair shielded, jacketed cable) for wirewrapping to wirewrap adapter PN 3DH04178AB. See Figure 3-18 for pinout. Refer to Table 3-6 for mating cable wiring and color code. J307 J315 J313 J308 J309 J310 J305 J318 J312 J312 J316 J317 J302 LMW-7238 02/23/04 GND CALL DETECT AUDIO TIP OUT M LEAD AUDIO TIP IN J316/J317 AUDIO RING IN E LEAD AUDIO RING OUT CALL COMMON FRONT VIEW Figure 3-17 Audio Connectors Location and Pinout 3-25 Table 3-6 Audio Mating Cable Wiring and Color Codes END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION AUDIO TIP IN AUDIO RING IN AUDIO M LEAD AUDIO E LEAD AUDIO TIP OUT AUDIO RING OUT CALL DETECT CALL COMMON GND NOT USED 01 06 02 07 03 08 04 09 05 10 BLACK RED BLACK WHITE BLACK GREEN BLACK BLUE BLACK YELLOW BLACK RED BLACK WHITE BLACK GREEN BLACK BLUE BLACK YELLOW 03 08 07 02 01 06 04 09 05 10 AUDIO TIP OUT AUDIO RING OUT AUDIO E LEAD AUDIO M LEAD AUDIO TIP IN AUDIO RING IN NOT USED NOT USED GND NOT USED J301 FUNCTION J308 J315 J309 J305 J318 J313 J310 J316 J316 J317 J302 J317 J312 WIRE WRAP ADAPTER P316 P317 91 P101 PN 3DH04178 AB P102 WIRE WRAP ADAPTER PINS P316 P101 AUDIO TIP IN AUDIO RING IN AUDIO M LEAD AUDIO TIP OUT AUDIO RING OUT AUDIO E LEAD CALL DETECT CALL COMMON GND A1 A2 A3 A4 A5 A6 A7 A8 A9 P317 P102 AUDIO TIP IN AUDIO RING IN AUDIO M LEAD AUDIO TIP OUT AUDIO RING OUT AUDIO E LEAD CALL DETECT CALL COMMON GND A1 A2 A3 A4 A5 A6 A7 A8 A9 Figure 3-18 Audio Wirewrap Adapter Pinout 3-26 LMW-7055 09/06/03 3.15.4 RS-232-1, RS-232-2 (J312, J313) J301 Recommended connectorized cable assembly – PN 695-4125-021 through 025 (26 AWG 5 pair shielded, jacketed cable with 9-pin D-type connector on each end). See Figure 3-19 for shelf connector locations and pinout. Refer to Table 3-7 for mating cable wiring and color code. J307 J315 J308 J318 J313 J309 J310 J305 J312 J316 J317 J302 LMW-7056 07/23/02 GND RS-232 IN RS-232 OUT J312/J313 FRONT VIEW Figure 3-19 RS-232 Connectors Location and Pinout 3-27 Table 3-7 RS-232 Mating Cable Wiring and Color Codes J312/J313 MDR-8000 J312/J313 J312/J313 MDR-8000 FUNCTION END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION NOT USED 01 BLACK BLACK 01 NOT USED NOT USED 06 RED RED 06 NOT USED RS-232 OUT/ RS-232-1 OUT* 02 BLACK BLACK 03 RS-232 IN/ RS-232-1 IN* NOT USED 07 WHITE WHITE 08 NOT USED RS-232 IN/ RS-232-1 IN* 03 BLACK BLACK 02 RS-232 OUT/ RS-232-1 OUT* NOT USED 08 GREEN GREEN 07 NOT USED NOT USED/ RS-232-2 OUT* 04 BLACK BLACK 04 NOT USED/ RS-232-2 OUT* NOT USED/ RS-232-2 IN* 09 BLUE BLUE 09 NOT USED/ RS-232-2 IN* GND 05 BLACK BLACK 05 GND NOT USED 10 YELLOW YELLOW 10 NOT USED *J312 on CommPak Radio 3.15.5 MCS-11 Connections When MCS is selected to be placed on one of the three service channels and then RSS is enabled and properly addressed, applicable ports on the controller module are enabled. This allows the user to interface external MCS-11 Monitor and Control System equipment at any or all four connectors on the backplane (J307, J308, J309, and J310). Two connectors (J308 and J309) are synchronous, parallel, data ports and provide CLK outputs. Connectors J307 and J310 are asynchronous ports. For proper operation, MCS-11 must be provisioned using the following guidelines: a. MCS-11 must be selected as one of the service channels. b. MCS must be assigned a valid address c. The MCS RSS must be set to ON for each radio with a unique RSS address. Refer to Appendix B on the attached CD for address details. At a site, typically only one RSS is turned on. Station scanners at all other radios at that site are normally jumpered to the RSS enabled radio to allow access to their detail scanners. If station scanners are properly wired, detail scanners always respond, regardless of whether RSS is provisioned ON or OFF. 3-28 Note MCS-11 must be provisioned MCS-11 J310 Master/Junction to enable XMT, RCV, and OUTPUT clocks. If an external modem is being used, provision MCS-11 for MCS-11 J310 Modem. This selection disables XMT, RCV, and OUTPUT clocks and all MCS-11 clocks must now be provided by the external modem. d. MCS-11 J310 Master/Junction must be selected unless an external modem is connected to the radio. If an external modem is used it must provide all MCS-11 clocks and the radio must be provisioned MCS-11 J310 Modem. Note When provisioned J308 Input Clock, J308 and J309 RCV CLK and XMT CLK and J308 OUTPUT CLK are disabled. Select J308 Output Clock to send a 64 kb/s clock to external equipment (OUTPUT CLK J308-4/12) and also enable RCV CLK and XMT CLK. e. MCS-11 J308 Output Clock must be selected unless an external clock source is provided that will supply all MCS-11 clocks. If an external clock source is used, the radio must be provisioned MCS-11 J308 Input Clock. 3.15.5.1 MCS-11 (J307) Note If the radio is provisioned Repeater, port 2 on the controller, that connects to J307, is disabled. At a repeater, you can use J310 in lieu of J307 for connecting the TSM polling engine to the radio. MCS-11 connector J307 is used to connect to a TSM (-2500, -3500, or -8000) polling engine at a master terminal. Recommended connectorized cable assembly – PN 695-4126-007/009/012 (26 AWG 8 pair shielded, jacketed cable). See Figure 3-20 for shelf connector location and pinout. Refer to Table 3-8 for mating cable pinout and color code. See Figure 3-21 for typical connection scheme. 3-29 J301 J307 J315 J313 J308 J318 J309 J305 J310 J312 J316 J317 J302 LMW-7052 07/23/02 XMT DATA + RTN CLK + XMT CLK + RCV DATA + RCV CLK + J307 15 RCV CLK – RCV DATA – XMT CLK – RTN CLK – XMT DATA – FRONT VIEW Figure 3-20 MCS-11 Master Connector Location and Pinout 3-30 Table 3-8 MCS-11 Master Connector J307 Mating Cable Wiring and Color Codes J307 MDR-8000 POLLING ENGINE FUNCTION END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION RCV CLK + 01 BLACK BLACK 01 RCV CLK + RCV CLK- 09 RED RED 09 RCV CLK- RCV DATA + 02 BLACK BLACK 02 RCV DATA + RCV DATA - 10 WHITE WHITE 10 RCV DATA - XMT CLK + 03 BLACK BLACK 03 XMT CLK + XMT CLK - 11 GREEN GREEN 11 XMT CLK - RETURN CLK + 04 BLACK BLACK 04 RETURN CLK + RETURN CLK - 12 BLUE BLUE 12 RETURN CLK - XMT DATA + 05 BLACK BLACK 05 XMT DATA + XMT DATA - 13 YELLOW YELLOW 13 XMT DATA - NOT USED 06 BLACK BLACK 06 OFF HOOK + NOT USED 14 BROWN BROWN 14 OFF HOOK - NOT USED 07 BLACK BLACK 07 RCV DATA NOT USED 15 ORANGE ORANGE 15 SIG GND NOT USED 08 RED RED 08 DTR NOT USED 16 WHITE WHITE 16 NOT USED 3-31 SITE C SITE D MDR-8000 MDR-8000 B1 TERM. DS307 B2 RPTR DS308 J307 J401 695-4126-007/009/012 MDR-8000 B3 RPTR DS309 J401 REPEATER CABLE 695-7836-001 THRU -005 POLLING ENGINE MDR-8000 B4 TERM 4 DS310 J308 J310 695-7837-001 THRU -005 CROSSWIRE STRAIGHT CABLE 695-7837-025 SITE B A10 A9 TERM TERM J306 J309 J311 MDR-4000e MDR-4000e SITE E J308 B5 TERM J309 DS303 B6 TERM DS304 MDR-8000 MDR-8000 695-7837-021 THRU -025 SITE F J308 695-7801-001 J202 MUX STRAIGHT CABLE 695-7837-025 B7 TERM J309 DS301 B8 TERM DS302 MDR-8000 MDR-8000 SITE G DMX-3003N E1A J310 E2A RPTR G7572 J314 TERM P7572 MDR-6000 MDR-6000 RPTR CABLE 372-0546-020/050/070 SITE H E3A E4A RPTR J314 S7341 TERM T7341 MDR-6000 LEGEND: XXXX MCS-11 ADDRESS YYYY CONFIGURATION ZZZZ ELMC ADDRESS SITE A MDR-8000 J308/J309 PROVISIONING NOTES 1. PROVISION RPTR DS309 (FIRST RADIO IN CHAIN) J308 OUTPUT CLOCK. DS3ZZ = RADIO CAPACITY (DS3) AND SHELF NUMBER (DS301 - SHELF 1) 2. PROVISION ALL OTHER RADIOS IN DAISY CHAIN (TERM DS303 AND TERM DS301) J308 INPUT CLOCK. MDR-1023 06/08/04 Figure 3-21 Typical MCS-11 System 3-32 MDR-6000 3.15.5.2 MCS-11 Repeater-to-Spur Daisy Chain Connection (J308/J309) Note MCS-11 must be provisioned MCS-11 J310 Master/Junction to enable XMT, RCV, and OUTPUT clocks. If an external modem is being used, provision MCS-11 for MCS-11 J310 Modem. This selection disables XMT, RCV,OUTPUT clocks and all MCS-11 clocks must now be provided by the external modem. Note Multiple radios at a site can be provisioned and connected to operate using a common XMT and RCV clock. In this scenario, one radio is provisioned to supply the clocks. All other radios are provisioned to sync off the supplied clocks. Provision the radio supplying the clocks J308 Output Clock. Provision all other radios at the site J308 Input Clock. MCS-11 connector J308/J309 is typically used to connect a repeater to a spur or multiple spurs in a daisy chain system configuration. Either repeater shelf 1 or repeater shelf 2 may feed the spur shelf. The first connection out of the repeater must be crosswired from J308 to J308. Then, every shelf from the spur must be wired 1:1, J309 to J308, in a daisy-chain fashion. CROSSWIRED CABLE ASSEMBLY – Recommended connectorized cable assembly – PN 695-7837-001 through -005 (26 AWG 8 pair shielded, jacketed cable with 15-pin D-type connector on each end). See Figure 3-22 for shelf connector J308 location and pinout. See Figure 3-22 for shelf connector J309 location and pinout. Refer to Table 3-9 for J308 to J308 mating cable pinout and color code. See Figure 3-21 for typical connection scheme. DAISY CHAIN CABLE ASSEMBLY – Recommended connectorized cable assembly – PN 695-7837-021 through -025 (26 AWG 8 pair shielded, jacketed cable with 15-pin D-type connector on each end, wired 1:1.) Refer to Table 3-10 for J309 to J308 mating cable pinout and color code. See Figure 3-21 for typical connection scheme. 3-33 J301 J307 J315 J313 J308 J318 J309 J310 J305 J312 J316 J317 J302 MDR-1012 04/12/04 J308 15 OFF HOOK + XMT DATA + OFF HOOK + XMT DATA + CLK OUT + XMT CLK + RCV DATA + RCV CLK + J309 15 RCV CLK – RCV DATA – XMT CLK – CLK OUT – XMT DATA – OFF HOOK – FRONT VIEW XMT CLK + RCV DATA + RCV CLK + RCV CLK – RCV DATA – XMT CLK – XMT DATA – OFF HOOK – FRONT VIEW Figure 3-22 MCS-11 Connector J308 and J309 Location and Pinout 3-34 Table 3-9 J308-to-J308 Mating Cable Wiring and Pinout J308 MDR-8000 J308/J308 J308 MDR-8000 FUNCTION END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION RCV CLK + 01 BLACK BLACK 03 XMT CLK + RCV CLK- 09 RED RED 11 XMT CLK- RCV DATA + 02 BLACK BLACK 05 XMT DATA + RCV DATA - 10 WHITE WHITE 13 XMT DATA - XMT CLK + 03 BLACK BLACK 01 RCV CLK + XMT CLK - 11 GREEN GREEN 09 RCV CLK - 04 BLACK BLACK 04 NOT USED BLUE 12 NOT USED BLACK 02 RCV DATA + YELLOW 10 RCV DATA - BLACK 06 OFF HOOK + BROWN 14 OFF HOOK - BLACK 07 NOT USED ORANGE 15 NOT USED RED 08 NOT USED CLK OUT+ CLK OUT - 12 BLUE XMT DATA + 05 BLACK XMT DATA - 13 YELLOW OFF HOOK + 06 BLACK OFF HOOK - 14 BROWN NOT USED 07 BLACK NOT USED 15 ORANGE NOT USED 08 RED NOT USED WHITE WHITE NOT USED Table 3-10 J309-to-J308 Mating Cable Wiring and Pinout 309 MDR-8000 J309/J308 J308 MDR-8000 FUNCTION END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION RCV CLK + 01 BLACK BLACK 01 RCV CLK + RCV CLK- 09 RED RED 09 RCV CLK- RCV DATA + 02 BLACK BLACK 02 RCV DATA + RCV DATA - 10 WHITE WHITE 10 RCV DATA - XMT CLK + 03 BLACK BLACK 03 XMT CLK + XMT CLK - 11 GREEN GREEN 11 XMT CLK - BLACK 04 NOT USED BLUE 12 NOT USED BLACK 05 XMT DATA + YELLOW 13 XMT DATA - BLACK 06 OFF HOOK + 04 BLACK CLK OUT - CLK OUT+ 12 BLUE XMT DATA + 05 BLACK XMT DATA - 13 YELLOW OFF HOOK + 06 BLACK OFF HOOK - 14 BROWN NOT USED 07 BLACK NOT USED 08 ORANGE NOT USED 15 RED NOT USED 16 WHITE BROWN 14 OFF HOOK - BLACK 07 NOT USED ORANGE 15 NOT USED RED 08 NOT USED WHITE 16 NOT USED 3-35 3.15.5.3 MCS-11 Spur Connection (J310) MCS-11 connector J310 can be used to connect to a spur shelf and is the preferred connection to the external DMX-3003N MUX. When connecting to a MDR-4000e or MDR-6000 radio use J310 on all of the radios for best results. J301 Recommended connectorized cable assembly – PN 695-4126-031 through -035 (26 AWG 8 pair shielded, jacketed cable with 15-pin D-type connector on each end). See Figure 3-23 for shelf connector J310 location and pinout. Refer to Table 3-11 for mating cable wiring and color code. See Figure 3-21 for typical connection scheme. J307 J307 J315 J313 J308 J318 J309 J305 J310 J312 J316 J317 J302 LMW-7072 07/23/02 XMT DATA + RTN CLK + XMT CLK + RCV DATA + RCV CLK + J310 15 RCV CLK – RCV DATA – XMT CLK – RTN CLK – XMT DATA – FRONT VIEW Figure 3-23 MCS-11 Spur Connector J310 Location and Pinout 3-36 Table 3-11 MCS-11 Spur Connector J310 Mating Cable Wiring and Pinout J310 MDR-8000 J310/J310 J310 MDR-8000 FUNCTION END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION RCV CLK + 01 BLACK BLACK 04 RETURN CLK + RCV CLK- 09 RED RED 12 RETURN CLK- RCV DATA + 02 BLACK BLACK 05 XMT DATA + RCV DATA - 10 WHITE WHITE 13 XMT DATA - XMT CLK + 03 BLACK BLACK 03 XMT CLK + XMT CLK - 11 GREEN GREEN 11 XMT CLK - RETURN CLK + 04 BLACK BLACK 01 RCV CLK + RETURN CLK - 12 BLUE BLUE 09 RCV CLK - XMT DATA + 05 BLACK BLACK 02 RCV DATA + XMT DATA - 13 YELLOW YELLOW 10 RCV DATA - NOT USED 06 BLACK BLACK 06 NOT USED NOT USED 14 BROWN BROWN 14 NOT USED NOT USED 07 BLACK BLACK 07 NOT USED NOT USED 15 ORANGE ORANGE 15 NOT USED NOT USED 08 RED RED 08 NOT USED NOT USED 16 WHITE WHITE 16 NOT USED 3.15.6 ELMC (J315, J318) As a standard feature, the Extended Link Monitor Channel (ELMC) function allows local provisioning, alarms, status information, and control commands for the local radio and, (with the exception of wayside DS1), alarms, status information, control for addressable remote radios. For wayside DS1 status, the ELMC option key (695-5647-019 or -020) must be installed on the AE-37Y Controller. For remote provisioning and downloading capability, the ELMC option key (695-5647-018 or 695-5647-020) must be installed on the AE-37Y Controller. Refer Table 3-12 for details. Recommended connectorized cable assembly – PN 695-4125-006/013 (26 AWG 5 pair shielded, jacketed cable). See Figure 3-24 for shelf connectors locations and pinout. Refer to Table 3-13 for mating cable wiring and color code. See Figure 3-25 for typical connection scheme. 3-37 Table 3-12 ELMC Option Keys ELMC Option Key 695-5647-018 Required for remote provisioning and downloading on DS1/E1 radios, and DS3 and OC3 radios without wayside DS1 ELMC Option Key 695-5647-019 Required for status of DS3 and OC3 radios with wayside DS1 (no remote provisioning or download capability provided) ELMC Option Key 695-5647-020 Required for remote provisioning and downloading of DS3 and OC3 radios with wayside DS1 Note ELMC 1 connector J318 and ELMC 2 connector J315 are wired in parallel. You can connect J315 to J315, J315 to J318, or J318 to J318. A typical connection scheme is shown. Table 3-13 ELMC Connector J315/J318 Mating Cable Wiring and Pinout J315/J318 MDR-8000 FUNCTION END 1 WIRE COLOR PAIR WIRE COLOR END 2 FUNCTION RCV+ 01 BLACK BLACK 02 XMT+ RCV- 06 RED RED 07 XMT- XMT+ 02 BLACK BLACK 01 RCV+ XMT- 07 WHITE WHITE 06 RCV- NOT USED 3-38 J315/J318 MDR-8000 BLACK GND 03 GREEN NOT USED 04 BLACK NOT USED 08 BLUE NOT USED 05 BLACK NOT USED 09 YELLOW BLACK NOT USED GREEN 03 GND BLACK 05 NOT USED BLUE 09 NOT USED BLACK 04 NOT USED YELLOW 08 NOT USED J301 J307 J315 J308 J313 J318 J309 J305 J310 J312 J316 J317 J302 LMW-7237 02/23/04 GND XMT + J315/J318 RCV + RCV – XMT – FRONT VIEW Figure 3-24 ELMC Connectors Location and Pinout 3-39 SITE A SITE C MDR-8000 MDR-8000 B1 TERM. DS307 B2 RPTR DS308 J401 SITE G B3 RPTR DS309 J401 B4 TERM 4 DS310 J318 REPEATER CABLE 695-7836-001 THRU -005 SITE B MDR-8000 MDR-8000 695-4125-006/013 CROSSWIRE SITE H J315 SITE D J318 A10 MDR-8000 A9 J102 MDR-4000E B6 TERM DS304 MDR-8000 695-4125-006/013 CROSSWIRE TERM TERM B5 TERM DS303 MDR-4000E J318 B7 TERM DS301 PIGTAIL CABLE 695-4125-008 MDR-8000 SITE E E2A MDR-6000 RPTR J314 T7572 E1A TERM G7572 MDR-6000 J309 B8 J318 TERM DS302 MDR-8000 695-4125-006/013 CROSSWIRE MDR-8000 MDR-8000 TERM DS105 TERM DS106 J318 J318 SITE I 695-4125-006/013 CROSSWIRE REPEATER CABLE 372-0456 020/050/070 SITE F J314 E4A E3A RPTR J309 T7341 TERM S7341 MDR-6000 MDR-6000 Note When connecting MDR-8000 radios with Windows USI to radios with DOS USI, check the DOS USI ELMC address for space, dash, slash, asterisk, or underscore. The Windows USI cannot recognize a space, dash, slash, asterisk, or underscore. Change the DOS ELMC address to a 5-character alphanumeric address without the prohibited characters. MDR-1026 06/12/04 Figure 3-25 Typical ELMC Connections 3-40 3.16 FOREIGN ALARM INTERFACE (J305) Recommended connectorized cable assembly – PN 695-4121-001/003 (24 AWG 25 pair cable). See Figure 3-26 for shelf connector location and pinout. Refer to Table 3-13 for mating cable pinout and color code. or Recommended wirewrap cable – PN 424-0429-020 (22 AWG 30-pair twisted cable) for use with wirewrap adapter PN 695-4171-002. Refer to Table 3-14 for pinout. Note J301 TBOS connections on J305 share pins with station alarms 13 through 16 and either TBOS or station alarms 13 through 16 is selected (provisioned) on the USI Radio Configuration Provisioning screen. J307 J315 J313 J308 J318 J309 J305 J310 J312 J316 J317 J302 LMW-7060 07/23/02 J305 26 50 25 24 49 WIRE WRAP ADAPTER FRONT VIEW 26 Figure 3-26 Alarm/Status/TBOS Connector J305 Location and Pinout 3-41 Table 3-14 Alarm/Status Connector J305 Mating Cable Wiring and Pinout ALM/STATUS/CONTROL PIN PR WIRE COLOR REMARKS A XMT ALM OUT 01 WHT/BLU ALARM OUTPUT FROM RELAY INTFC NOT USED* 26 BLU/WHT N/A A RCV ALM OUT 02 WHT/ORN ALARM OUTPUT FROM RELAY INTFC NOT USED* 27 ORN/WHT N/A CONTROLLER FAIL ALM OUT 03 WHT/GRN ALARM OUTPUT FROM RELAY INTFC SWITCH I/O OUT 28 GRN/WHT CONTROL OUTPUT FROM RELAY INTFC SWITCH XMTR OUT 04 WHT/BRN CONTROL OUTPUT FROM RELAY INTFC SWITCH RCVR OUT 29 BRN/WHT CONTROL OUTPUT FROM RELAY INTFC A XMT IN SVCE OUT 05 WHT/SLT STATUS OUTPUT FROM RELAY INTFC NOT USED* 30 SLT/WHT N/A A RCV IN SVCE OUT 06 RED/BLU STATUS OUTPUT FROM RELAY INTFC NOT USED* 31 BLU/RED N/A A I/O IN SVCE OUT 07 RED/ORN STATUS OUTPUT FROM RELAY INTFC NOT USED* 32 ORN/RED N/A PWR SUPPLY ALM OUT 08 RED/GRN ALARM OUTPUT FROM RELAY INTFC NOT USED* 33 STATION ALM 9 IN 09 STATION ALM 1 IN 34 STATION ALM 10 IN 10 STATION ALM 2 IN 35 STATION ALM 11 IN 11 STATION ALM 3 IN 36 STATION ALM 12 IN 12 STATION ALM 4 IN 37 TBOS XMT- DATA IN OR STATION ALM 13 IN 13 STATION ALM 5 IN TBOS XMT+ DATA IN OR STATION ALM 14 IN STATION ALM 6 IN 39 3-42 GRN/RED N/A RED/BRN RELAY INPUT FROM CUSTOMER EQUIPMENT BRN/RED RELAY INPUT FROM CUSTOMER EQUIPMENT RED/SLT RELAY INPUT FROM CUSTOMER EQUIPMENT SLT/RED RELAY INPUT FROM CUSTOMER EQUIPMENT BLK/BLU RELAY INPUT FROM CUSTOMER EQUIPMENT BLU/BLK RELAY INPUT FROM CUSTOMER EQUIPMENT BLK/ORN RELAY INPUT FROM CUSTOMER EQUIPMENT ORN/BLK RELAY INPUT FROM CUSTOMER EQUIPMENT 13 BLK/GRN SERIAL DATA INPUT TO RADIO CONTROLLER OR INPUT FROM CUSTOMER EQUIPMENT TO RELAY INTFC CARD (PROVISIONABLE) 38 13 GRN/BLK INPUT FROM CUSTOMER EQUIPMENT 14 14 BLK/BRN SERIAL DATA INPUT TO RADIO CONTROLLER OR INPUT FROM CUSTOMER EQUIPMENT TO RELAY INTFC CARD (PROVISIONABLE) BRN/BLK INPUT FROM CUSTOMER EQUIPMENT 10 11 12 Table 3-14 (Cont.) Alarm/Status Connector J305 Mating Cable Wiring and Pinout ALM/STATUS/CONTROL PIN PR WIRE COLOR TBOS RCV- DATA OUT OR STATION ALM 15 IN 15 15 BLK/SLT SERIAL DATA INPUT TO RADIO CONTROLLER OR INPUT FROM CUSTOMER EQUIPMENT TO RELAY INTFC CARD (PROVISIONABLE) STATION ALM 7 IN 40 SLT/BLK INPUT FROM CUSTOMER EQUIPMENT TBOS RCV+ DATA OUT OR STATION ALM 16 IN 16 YEL/BLU SERIAL DATA INPUT TO RADIO CONTROLLER OR INPUT FROM CUSTOMER EQUIPMENT TO RELAY INTFC CARD (PROVISIONABLE) STATION ALM 8 IN 41 BLU/YEL INPUT FROM CUSTOMER EQUIPMENT CONTROL 1 OUT 17 YEL/ORN OUTPUT TO CUSTOMER EQUIPMENT CONTROL STATUS 1 IN 42 ORN/YEL INPUT FROM CUSTOMER EQUIPMENT IN RESPONSE TO CONTROL 1 OUTPUT CONTROL 2 OUT 18 YEL/GRN OUTPUT TO CUSTOMER EQUIPMENT CONTROL STATUS 2 IN 43 GRN/YEL INPUT FROM CUSTOMER EQUIPMENT IN RESPONSE TO CONTROL 2 OUTPUT CONTROL 3 OUT 19 CONTROL STATUS 3 IN 44 CONTROL 4 OUT 20 CONTROL STATUS 4 IN 45 CONTROL 5 OUT 21 CONTROL STATUS 5 IN 46 CONTROL 6 OUT 22 CONTROL STATUS 6 IN 47 PATH ALM OUT 23 LOSS OF INPUT OUT 48 MAJOR ALM/VISUAL ALM OUT 24 RACK ALM RETURN 49 RACK ALM OUT 25 MINOR ALM/AUDIBLE ALM OUT 50 16 17 18 19 20 21 22 23 24 25 REMARKS YEL/BRN OUTPUT TO CUSTOMER EQUIPMENT BRN/YEL INPUT FROM CUSTOMER EQUIPMENT IN RESPONSE TO CONTROL 3 OUTPUT YEL/SLT OUTPUT TO CUSTOMER EQUIPMENT SLTYEL INPUT FROM CUSTOMER EQUIPMENT IN RESPONSE TO CONTROL 4 OUTPUT VIO/BLU OUTPUT TO CUSTOMER EQUIPMENT BLU/VIO INPUT FROM CUSTOMER EQUIPMENT IN RESPONSE TO CONTROL 5 OUTPUT VIO/ORN OUTPUT TO CUSTOMER EQUIPMENT ORN/VIO INPUT FROM CUSTOMER EQUIPMENT IN RESPONSE TO CONTROL 6 OUTPUT VIO/GRN ALARM OUTPUT FROM CONTROLLER GRN/VIO ALARM OUTPUT FROM CONTROLLER VIO/BRN ALARM OUTPUT FROM CONTROLLER (PROVISIONABLE MAJOR/MINOR OR VISUAL/AUDIBLE ON USI SCREEN) VIO/BRN INPUT TO CONTROLLER VIO/SLT OUTPUT FROM CONTROLLER SLT/VIO ALARM OUTPUT FROM CONTROLLER (PROVISIONABLE MAJOR/MINOR OR VISUAL/AUDIBLE ON USI SCREEN) *Wired but not used 3-43 3.17 ALARM, STATUS, CONTROLS INTERCONNECT See Figure 3-27 for interconnect diagram. The AE-27( ) Relay Interface provides alarm, control and status inputs, and alarm, status and control relay outputs. All output relays can be disabled or provisioned normally open or normally closed as follows: Normally open (NO) – relays are normally de-energized and relay contacts are open. When activated, relays are energized. Relay contacts close, connecting the output to ground. Normally closed (NC) – relays are normally energized and relay contacts are closed and grounded. When activated, relays are de-energized. Relay contacts open, presenting an open (high impedance) to the output. Rack ALM Return, Pin 49 is a ground point for use with Rack ALM Out. It is a signal ground (low current) not used for battery voltage or high current ground. 3-44 J305 SWITCH XMTR SWITCH RCVR RELAY INTERFACE J305 PATH ALM SWITCH I/O LOSS OF INPUT ALM STATION ALM 1 A XMT ALM STATION ALM 2 B XMT ALM STATION ALM 3 A RCV ALM STATION ALM 4 B RCV ALM STATION ALM 5 STATION ALM 6 POWER SUPPLY ALM STATION ALM 7 CONTROLLER FAIL STATION ALM 8 STATION ALM 9 A XMTR IN SERV STATION ALM 10 B XMTR IN SERV STATION ALM 11 A RCVR IN SERV STATION ALM 12 B RCVR IN SERV STATION ALM 13* A I/O IN SERV STATION ALM 14* B I/O IN SERV STATION ALM 15 IN* SW OFF NORMAL STATION ALM 16 IN* CONTROL 1 CONTROL STATUS 1 CONTROL 2 CONTROL STATUS 2 CONTROL 3 CONTROL STATUS 3 CONTROL 4 CONTROL STATUS 4 CONTROL 5 CONTROL STATUS 5 CONTROL 6 CONTROL STATUS 6 DATA CONTROL TBOS RCV -* MAJOR / VISUAL ALM TBOS RCV +* MINOR / AUDIBLE ALM TBOS XMT -* RACK ALM TBOS XMT +* NOTE: ALL RELAY CONTACTS ARE SHOWN AS SWITCHES FOR DOCUMENTATION PURPOSES. CONTROLLER LMW-7064 5/12/04 * PROVISIONABLE TBOS TO/FROM CONTROLLER OR STATION ALARM 13-16 TO RELAY INTFC Figure 3-27 Alarm and Status Relays/TBOS Interconnect 3-45 3.17.1 Controller Bus The Relay Interface communicates with the AE-37( ) Controller card via the processor bus and the data bus. The processor bus, consisting of three address lines, two control lines, and a clock, is applied to a XCVR. The data bus contains the eight data lines (D0-D7) and is applied to a separate transceiver. Interface with the relay transceivers is provided by the XCVR data bus. When commanded by the AE-37( ) Controller, the decoder/DEMUX decodes and demultiplexes the address and enables the appropriate relay XCVR via the EN2-9 controls. The controller can then write alarm/status/control information to the relay XCVRs, or read alarm/status/control inputs from the relay XCVRs. Further descriptions of the controller interface signals follow: • Address lines A0 through A3 – HCMOS inputs. 100K Ohm pull-ups. Used by address decoders to enable output registers and input buffers. • Buffered bidirectional data lines D0 through D7 – HCMOS input/outputs. 10K Ohm pull-ups. Used to write data to output registers and read present bits or data from input buffers. • ECLK – 2 MHz bus clock. HCMOS input. 100K Ohm pull-up. • R/WF Read/Write False. HCMOS input. 100K Ohm pull-up. A logic 1 indicates data is being read from an input buffer or the present bits. A logic 0 indicates data is being written to an output register. • Relay Intfc CSF – Relay Interface Card Select False. HCMOS input. 100K Ohm pull-up. Chip select for relay interface card. Active low. 3.17.2 Control Inputs Nine buffered control inputs are provided. The inputs are diode protected from voltages outside of the 0 to +5 V range, and have a 10K Ohm resistor for current limiting purposes. In addition, each input has a 100K Ohm pull-up resistor. • Switch Transmitter (SWITCH TX) – buffered HCMOS input, sends signal to controller module to activate the transmitter that is currently not carrying traffic. • Switch Receiver (Switch RX) – buffered HCMOS input, sends signal to controller module to activate the receiver that is currently not carrying traffic. • Switch I/O Interface (SWITCH I/O) – buffered HCMOS input, sends signal to controller module to activate the stand-by I/O interface module. 3.17.3 Station Alarm Inputs/TBOS Interface Each radio shelf can accept/report up to 12 different user-defined station-type alarms, and, if provisioned Station Alarm 13-16, the radio can accept an additional four station alarms, for a total of 16. Station alarms 13 through 16 share pins on connector J305 with the four TBOS inputs and outputs. TBOS inputs and outputs are enabled by software when the radio is provisioned TBOS Display 1-8. When TBOS is enabled station alarms 13 through 16 are disabled. The alarm/status input signals are buffered HCMOS inputs, diode protected from voltages outside of the 0 to +5 V range, with 10 kilohm current limiting (series) resistor and 100 kilohm pull-up resistor. A logic 0 indicates an alarm state. A logic 1 (or open) indicates a non-alarm state. 3-46 3.17.4 Station Alarm Wiring See Figure 3-28. Use wire wrap adapter PN 695-4171-002 to connect station alarm inputs to the AE-27A Relay Interface module, via connector J305, in each rack. A typical connection scenario is shown. The station/shelf alarm for MCS-11 address A1A (MCS-11 alarm point 1) is connected by software. The station alarms for MCS-11 address A1B and A1C are assigned to MCS-11 Alarm points 2 and 3, respectively. WIRE WRAP ADAPTER (PN 695-4171-002) 24 RACK ALM 25 #1 STATION ALM (SEE NOTE) PIN 1 PDU J305 MDR-8000 SHELF MCS-11 ADDRESS A1A 34 36 49 35 26 #2 STATION ALM FAN ASSY HEAT DEFLECTOR J305 MDR-8000 SHELF MCS-11 ADDRESS A1B PIN 25 RACK ALM #3 STATION ALM FAN ASSY HEAT DEFLECTOR J305 MDR-8000 SHELF MCS-11 ADDRESS A1C PIN 25 RACK ALM NOTE FAN ASSY SOFTWARE AUTOMATICALLY CONNECTS RACK ALM OUTPUT FROM CONTROLLER J305-25 TO #1 STATION ALM INPUT J305-24. LMW-8002 07/28/02 Figure 3-28 Alarm and Status Relays/TBOS Interconnect 3-47 3.17.5 Relay Alarm/Status Outputs Eight alarm relay outputs and seven status relay outputs provide relay closure to ground (provisioned NO) or open (provisioned NC) when activated. All relays default to open if card power is lost, except the Power Supply alarms, which default to ground. The maximum contact rating for each relay is 0.5 A, 100 Vdc. The alarm/status relay outputs are: • Alarms: • Path Alarm– This summary alarm is activated by the following alarms: A/B Path Distortion A/B AGC Threshold • Loss of Input Alarm– This summary alarm is activated by the following alarms: Loss of DS3 input Loss of optical input (OC3) Loss of wayside DS1 input • A XMT – A-side transmitter failure. This summary alarm is activated by any of the following alarms on the A side: XMT SYNC Alarm RF Power Alarm Common Loss Alarm ATPC Timeout MUX Input Loss Alarm • B XMT – B-side transmitter failure. This summary alarm is activated by any of the following alarms on the B side: XMT SYNC Alarm RF Power Alarm Common Loss Alarm ATPC Timeout MUX Input Loss Alarm 3-48 • A RCV – B-side receiver failure. This summary alarm is activated by any of the following alarms on the A side: Channel Alarm RCV Frame Loss Eye Closure RSL Alarm • B RCV – B-side receiver failure. This summary alarm is activated by any of the following alarms on the B side: Channel Alarm RCV Frame Loss Eye Closure RSL Alarm • PWR Supply Alarm – This summary alarm is activated by any A or B power supply failure. • Controller Fail – relay is activated if a card select has not been detected in the previous approximately 200 msec. • Status: • A XMTR In Service – A-side transmitter module is on-line. • B XMTR In Service – B-side transmitter module is on-line. • A RCVR In Service – A-side receiver module is on-line. • B RCVR In Service – B-side receiver module is on-line. • A I/O In Service – A-side I/O interface module is on-line. • B I/O In Service – B-side I/O interface module is on-line. • Switch Off Normal – Click on OFF NORM LED on USI Status Alarm screen to view message. Indicates manual control enabled or one of following conditions exists: 3-49 OFF NORMAL MESSAGE DISPLAYED ON USI STATUS ALARM SCREEN: A/B Side PA Off – PA ON/OFF switch on A or B power supply is set to OFF. A/B Side LIO SPI Fail – XMT or RCV circuit failure on Low Capacity I/O ASIC in A or B DS1 I/O interface module. A/B Side RCV SPI Fail – Failure on the Serial Processor Interface bus causing loss of communication between the controller and RCV circuits on the I/O interface module. A/B Side DS1 SPI Fail – Failure on the Serial Processor Interface bus causing loss of communication between the controller and DS1 interface circuits on the I/O interface module. Fan Alarm – Failure of one or more cooling fans or failure of the fan control module on the fan assembly. I/O Loopback On – I/O LOOPBACK function is enabled on USI control screen. DS1 Line 1-3 Loopback On – DS1 LINE LOOPBACK RCV to XMT 1-3 function is enabled on USI control screen. A/B RCV Prov. ERROR UNIRCV – Failure in communication between processor on controller and UNIRCV ASIC on DS3 I/O interface module. A/B DS1 Prov. ERROR LEGHORN – Failure in communication between processor on controller and Leghorn ASIC on I/O interface module. A/B ATPC LOW POWER LOCK – A or B Automatic Transmit Power Control low power lock function is enabled on USI control screen on DS1, DS3, or OC3 radio. Lock prevents ATPC from going high. A/B ATPC HIGH POWER LOCK – A or B Automatic Transmit Power Control high power lock function is enabled on USI control screen on DS1, DS3, or OC3 radio. Lock prevents ATPC from going low. EEPROM PROV DOES NOT MATCH MODULE PROV – Stored provisioning in controller memory does not match provisioning stored in module memory. XMTR Capacity Key Mismatch – Part numbers of capacity keys on A and B XMTRs are different. 3-50 RCVR Capacity Key Mismatch – Part numbers of capacity keys on A and B RCVRs are different. A/B Tx OVERRIDE – A or B XMTR has been switched and locked in-service using controls on the front panel of the controller module. Online XMTR will not switch out-of-service regardless of alarms. A/B Rx OVERRIDE – A or B RCVR has been switched and locked in-service using controls on the front panel of the controller module. Online RCVR will not switch out-of-service regardless of alarms. A/B I/O OVERRIDE – A or B I/O interface has been switched and locked in-service using controls on the front panel of the controller module. Online I/O interface will not switch out-of-service regardless of alarms. 3.17.6 Relay Control Outputs Note Control outputs and control status inputs operate together to perform control functions. The control status inputs to the relay interface must be properly wired to the external equipment that is being controlled by the associated control output in order to display the ON or OFF status on the USI control screen. Without the control status inputs, the control function on the USI screen will still turn on equipment/functions, but no status will be indicated and, once turned on, the equipment/function cannot be turned off. Six relay control outputs (CTRL 1-6) provide relay closure to ground (provisioned NC) or open (provisioned NO) when activated. These relays default to open if card power is lost. The maximum contact rating for each relay is 0.5 A, 100 Vdc. Nine buffered status inputs (CTRL STATUS 1-6) from the equipment controlled by the CTRL 1-6 outputs, verifying the controlled function. The inputs are diode protected from voltages outside of the 0 to +5 V range, and have a 10K Ohm resistor for current limiting purposes. In addition, each input has a 100K Ohm pull-up resistor. 3-51 3-52 This page intentionally left blank.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 88 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:ea97aa0a-7934-11d9-8bec-0003935a57b0 Modify Date : 2005:02:07 12:20:14-06:00 Create Date : 2005:02:07 10:45:27-06:00 Metadata Date : 2005:02:07 12:20:14-06:00 Document ID : uuid:aa8c0a80-7927-11d9-8bec-0003935a57b0 Format : application/pdf Title : 00-Book I 6 fullTOC.fm Creator : FrameMaker 7.0: LaserWriter 8 8.7.1 Author : Carol Producer : Acrobat Distiller 5.0.5 for MacintoshEXIF Metadata provided by EXIF.tools