Drawer Warmers
Electric
Models:
500-1D, 1DN
500-2D, 2DN
500-3D, 3DN
  •InstallatIon
 •operatIon
•MaIntenance
W164 N9221 Water Street P.O. Box 450 Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 800.558.8744
USA/CANADA
FAX: 262.251.7067 800.329.8744
U.S.A. ONLY
www.alto-shaam.com
500-1DN
500-2DN
500-3DN
500-1D
500-2D
500-3D
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual b
Delivery ............................................................................. 1
Unpacking ........................................................................ 1
Safety Procedures and Precautions ................................. 2
Installation
Installation Requirements ........................................... 3
Clearance Requirements ............................................. 3
Weights ....................................................................... 3
Product Capacity ........................................................ 3
500-1D, 2D, 3D
Cutout Dimensions .................................................. 4
Dimension Drawing ................................................ 4
Options and Accessories ........................................ 4
500-1DN, 2DN, 3DN
Cutout Dimensions .................................................. 5
Dimension Drawing ................................................. 5
Options and Accessories ........................................ 5
Electrical Specifications.............................................. 6
Operating Instructions
User Safety Information .............................................. 7
Before Initial Use ......................................................... 7
Heating Characteristics ............................................... 7
Food Product Tips ...................................................... 7
Operation .................................................................... 8
General Holding Guidelines ........................................ 9
Care and Cleaning
Cleaning and Preventative Maintenance .................. 10
Protecting Stainless Steel Surfaces.......................... 10
Cleaning Agents ........................................................ 10
Cleaning Materials .................................................... 10
Care and Cleaning .................................................... 11
Sanitation
Sanitation/Food Safety ............................................. 12
Internal Food Product Temperatures ........................ 12
Service
Thermostat Accuracy ................................................ 13
Trouble Shooting ....................................................... 13
Trouble Shooting - Error Codes ................................ 14
500-1D, 2D, 3D
Exterior Service Parts ......................................15-16
Service View - Drawer Assembly .......................... 17
500-1DN, 2DN, 3DN
Exterior Service Parts - ................................... 18-19
Service View - Drawer Assembly 500-DN ............. 20
Electronic Service Parts ............................................ 21
Wire Diagrams
Always refer to the wire diagram(s) included with the
unit for most current version.
Warranty
Transportation Damage and Claims .......... Back Cover
Limited Warranty ........................................ Back Cover
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 1
DELIVERY
This Alto-Shaam appliance has been
thoroughly tested and inspected to ensure only
the highest quality unit is provided. Upon
receipt, check for any possible shipping damage
and report it at once to the delivering carrier.
See Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached
items and accessories, may have been delivered
in one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to ensure prompt service in the event of a
warranty parts and labor claim.
This manual must be read and understood
by all people using or installing the equipment
model. Contact the Alto-Shaam Tech Team Service
Department if you have any questions concerning
installation, operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of
the unit.
UNPACKING
1. Carefully remove the
appliance from the
carton or crate.
NOTE: Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.
2. Read all instructions in this manual carefully
before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner
or manager of the business or to the person
responsible for training operators. Additional
manuals are available from the Alto-Shaam
Tech Team Service Department.
3. Remove all protective plastic film, packaging
materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.
®
®
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 2
CAUTION
Used to indicate the presence of a hazard that
can or will cause minor personal injury, property
damage, or a potential unsafe practice if the
warning included with this symbol is ignored.
CAUTION
Used to indicate the presence of a
hazard that can or will cause minor or
moderate personal injury or property
damage if the warning included with
this symbol is ignored.
DANGER
Used to indicate the presence of
a hazard that WILL cause severe
personal injury, death, or substantial
property damage if the warning
included with this symbol is ignored.
WARNING
Used to indicate the presence of
a hazard that CAN cause personal
injury, possible death, or major
property damage if the warning
included with this symbol is ignored.
1. This appliance is intended to cook, hold
or process foods for the purpose of human
consumption. No other use for this appliance is
authorized or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are
familiar with the purpose, limitations, and
associated hazards of this appliance. Operating
instructions and warnings must be read and
understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for
general reference only and are intended for use
by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all
supplied instructions, diagrams, schematics,
parts lists, notices, and labels must remain with
the appliance if the item is sold or moved to
another location.
NOTE: Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
SAFETY PROCEDURES
AND PRECAUTIONS
Knowledge of proper procedures is essential to the
safe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
NOTE
For equipment delivered for use
in any location regulated by the
following directive:
DO NOT DISPOSE OF ELECTRICAL
OR ELECTRONIC EQUIPMENT WITH
OTHER MUNICIPAL WASTE.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 3
SITE INSTALLATION
This Alto-Shaam
appliance must
be installed in a
location that will
permit it to function
for its intended
purpose and to allow
adequate clearance
for ventilation,
proper cleaning, and
maintenance access.
1. This appliance must be installed on a stable
and level surface.
2. DO NOT install this appliance in any area
where it may be affected by any adverse
conditions such as steam, grease, dripping
water, high temperatures, or any other severely
adverse conditions.
3. This appliance must be kept free and clear
of any obstructions blocking access for
maintenance or service.
®
CAUTION
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN
IN OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
DANGER
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
CAUTION
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
DANGER
DO NOT store or use gasoline or other
ammable vapors or liquids in the
vicinity of this or any other appliance.
MINIMUM CLEARANCE
REQUIREMENTS
bac k 3" (76mm)
lef t sid e 1" (25mm)
rig ht si de 1" (25mm)
top 2" (51mm)
INSTALLATION
WEIGHT (est.)
500-1D 500-2D 500-3D
net 80 lb (36 kg) 115 lb (52 kg) 150 lb (68 kg)
ship 90 lb (41 kg) 125 lb (57 kg) 165 lb (75 kg)
WEIGHT (est.)
500-1DN 500-2DN 500-3DN
net 67 lb (30 kg) 100 lb (45 kg) 130 lb (59 kg)
ship 75 lb (34 kg) 112 lb (51 kg) 145 lb (66 kg)
PRODUCT CAPACITY
36 lbs (16 kg) MaxiMuM each dRaweR
(34 baked potatoes, 50 diNNeR Rolls)
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 4
12-5/16"
(312mm)
24-5/8" (624mm)
43-3/8" (1101mm)
24-7/8" (631mm)
26-1/8" (664mm)
25-7/8" (657mm)
11-5/8"
(296mm)
18-15/16" (481mm)
500-1D
500-2D
500-3D
Electrical
Connection
6-3/4" (171mm) FOR
LEG STAND OR 5" (127mm)
CASTER STAND ASSEMBLY
4-7/8" (121mm)
FOR CASTER STAND ASSEMBLY
WITH 3" (76mm) CASTERS
Cord Length:
120V - 5' (1524mm)
208-240V - 8' (2438mm)
230V - 8' (2438mm)
SITE INSTALLATION
INSTALLATION
500-1D, 500-2D, 500-3D
OPTIONS & ACCESSORIES
Built-in Trim Kit
500-1D 5015147
500-2D 5015149
500-2d for BU2-48, BU2-72 5015151
500-2d for BU2-96 5015152
500-3d 5005153
Caster Stand Assembly
- with 5" (127mm) casters 15379
- with 3" (76mm) casters 5010920
Leg Stand Assembly 15380
Pan, oversize, 15" x 20" x 5" (381 x 508 x 127mm) PN-2123
perforated pan grid
15" x 20" (381mm x 508mm) 1231
12" x 20" (305mm x 508mm) 16642
CUTOUT DIMENSIONS (for units with built in trim)
Add 3/4" (19mm) to unit height and 1-1/2" (38mm) to unit width
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 5
26-1/8" (664mm)
31-3/16" (792mm)
11-5/8"
(296mm)
18-15/16" (481mm)
500-1D
500-2D
500-3D
Electrical
Connection
6-3/4" (171mm) FOR
LEG STAND OR 5" (127mm)
CASTER STAND ASSEMBLY
4-7/8" (121mm)
FOR CASTER STAND ASSEMBLY
WITH 3" (76mm) CASTERS
8-5/16"
(211mm)
16-11/16"
(423mm)
53-3/4" (1364mm)
24-7/8" (631mm)
Cord Length:
120V - 5' (1524mm)
208-240V - 8' (2438mm)
230V - 8' (2438mm)
SITE INSTALLATION
INSTALLATION
500-1DN, 500-2DN, 500-3DN
OPTIONS & ACCESSORIES
Built-in Trim Kit
500-1DN 5015148
500-2DN 5015150
500-3dN 5015154
Caster Stand Assembly
- with 5" (127mm) casters 55534
- with 3" (76mm) casters 5010921
Leg Stand Assembly 55535
Perforated pan grid, 12" x 20" (305mm x 508mm) 16642
CUTOUT DIMENSIONS (for units with built in trim)
Add 3/4" (19mm) to unit height and 1-1/2" (38mm) to unit width
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 6
1. An identification tag is permanently mounted on
the cabinet.
2. Plug cabinet into a properly grounded receptacle
ONLY, positioning the unit so the power supply
cord is easily accessible in case of an emergency.
Arcing will occur when connecting or
disconnecting the unit unless all controls are in
the “OFF” position.
3. If necessary, a proper receptacle or outlet
configuration as required for this unit, must be
installed by a licensed electrician in accordance
with applicable, local electrical codes.
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
ELECTRICAL
INSTALLATION
Wire diagrams are located inside the bonnet of the unit.
ELECTRICAL
voltage phase cycle/hz amps kW
120 1 60 5.3 0.64 nema 5-15p
15a, 125V plug
208-240 1 60 2.7 0.64 nema 6-15p
15a, 250V plug
230 1 50/60 2.6 0.59 cee 7/7,
220-230V plug
For CE approved units: To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances / metal parts
to provide sufficient protection against potential
difference. The terminal is marked
with the following symbol.
NOTE: Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 7
This appliance is intended for use in commercial
establishments where all operators are familiar with
the purpose, limitations, and associated hazards of
this appliance. Operating instructions and warnings
must be read and understood by all operators
and users.
1. Make sure the unit is connected to the
appropriate power source.
2. Use hand protection when handling
hot items.
3. Preheat the unit for 30 minutes before use.
4. Be certain only hot foods are placed into
the unit.
BEFORE INITIAL USE:
Before operating the unit, clean both the interior
and exterior of the unit with a clean, damp cloth
and mild soap solution. Rinse carefully. Clean
and install the drawer warmer pan(s). The drawer
assembly is completely removable. Clean as a
sanitation measure.
HEATING CHARACTERISTICS
The drawer warmer is equipped with a special
heating element. Through this Halo Heat concept,
the heating element is mounted against the walls of
the unit to provide an evenly applied heat source
controlled by a digital control. The design and
operational characteristics of the unit eliminate the
need for a moisture pan or a heat circulating fan.
Through even heat application, the quality of food
products is maintained up to several hours or more.
FOOD PRODUCT TIPS
Bread and Rolls
Breads and rolls are traditionally difficult to
hold for prolonged periods due to the very low
moisture content of these products. For best
results and longest possible holding life, it is
recommended these products be placed in a
plastic bag while in the warming drawer. Breads
and rolls should be held at a temperature no
higher than 120° to 140°F (49° to 60°C).
Potatoes
For the best results when holding potatoes:
1. Do not overcook.
Regardless of the temperature at which potatoes
are cooked or what type of oven is used, it is
important that this product does not achieve a
final internal product temperature in excess of
195°F (91°C). Over-cooking will further reduce
the moisture content and consequently, reduce
the holding life. Potatoes should be removed
from the oven when they reach an internal
temperature of approximately 190°F (88°C).
After they are removed from the oven, the
internal temperature will continue to increase.
2. Allow potatoes to stabilize before placing
in drawer warmer.
When potatoes are removed from a conventional
high-temperature oven, they have an extremely
high surface temperature. If they are placed in
the drawer warmer while they are this hot on the
outside, moisture will be pulled from the inside
of the potato and condensation will form on the
outside. Holding results under these conditions
will not be totally satisfactory. Remove potatoes
from the oven and allow the surface temperature
to stabilize before placing them in the controlled
holding atmosphere of the drawer warmer.
USER SAFETY INFORMATION
INSTALLATION
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 8
1. PREHEAT AT 200°F (93°C) FOR 30 MINUTES
BEFORE LOADING FOOD.
Push power switch to “ON” position. The unit will
begin operating at the previous set temperature.
2. Press the Up or Down Arrow Keys to 200°F (93°C).
Pressing and releasing the Arrow Keys will increase
the set point by 1 degree. Pressing and holding the
Arrow Key will increase set point by 10 degrees.
When Arrow Key is released, a new set point
temperature is set. The Set temperature will appear
in the Digital Display and the Heat Indicator Light
will illuminate. Press the Temperature Display Key
for three seconds at any time to display the Actual
inside air temperature.
To toggle between Set and Actual:
Factory default is to display Set temperature in the
Digital Display. To display Actual temperature:
Press and hold the Temperature Display Key and
the Up Arrow Key for 5 seconds. The control will
show ACT , then show the Actual temperature.
Repeat to toggle to Set point SET .
Press the Temperature Display Key at any time
to display the alternate temperature.
3. When the inside air temperature reaches the desired
holding temperature, the Heat Indicator Light will
turn off.
4. Load the cabinet with hot food only.
The purpose of the holding cabinet is to maintain
hot food at proper serving temperatures. Only
hot food should be placed into the cabinet. Before
loading the unit with food, use a food thermometer
to make certain all food products are at an internal
temperature range of 140° to 160°F (60° to 71°C).
All food not within the proper temperature
range should be heated before loading into the
holding cabinet.
5. Check to make certain the cabinet drawer is securely
closed, and using the Up and Down Arrow Keys,
set the temperature to 160°F (71°C).
THIS WILL NOT NECESSARILY
BE THE FINAL SETTING.
The proper temperature range for the food being
held will depend on the type and quantity of
product. Whether or not the optional drawer vents
should be open or closed will also depend on the
type of food being held. When holding food for
prolonged periods, it is advisable to periodically
check the internal temperature of each item to assure
maintenance of the proper temperature range.
Reset the holding temperature accordingly.
TO TOGGLE BETWEEN FAHRENHEIT
AND CELSIUS
Press the Temperature Display Key at any time to display
the alternate temperature.
The factory default is Fahrenheit. To change to Celsius:
1. Press and hold the Temperature Display Key and
the Down Arrow Key for 5 seconds.
2. The control will show .
C for 3 seconds to verify
selection and then show the temperature. (Set Point
or Actual, whichever the user has selected) in ºC.
3. Repeat to toggle to Fahrenheit.
Note: With a power failure, factory test, etc., the control
will retain the ºC or ºF setting selected by the user when
power is restored.
OPERATION
OPERATING INSTRUCTIONS
I
o
I
o
On/Off Power
Switch
Digital
Display
Up/Down
Arrow Keys
Heat
Indicator Light
Temperature
Display Key
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 9
GENERAL HOLDING GUIDELINES
Chefs, cooks and other specialized food service
personnel employ varied methods of cooking. Proper
holding temperatures for a specific food product
must be based on the moisture content of the
product, product density, volume, and proper serving
temperatures. Safe holding temperatures must also
be correlated with palatability in determining the
length of holding time for a specific product.
Halo Heat maintains the maximum amount of product
moisture content without the addition of water,
water vapor, or steam. Maintaining maximum
natural product moisture preserves the natural
flavor of the product and provides a more genuine
taste. In addition to product moisture retention, the
gentle properties of Halo Heat maintain a consistent
temperature throughout the cabinet without the
necessity of a heat distribution fan, thereby preventing
further moisture loss due to evaporation
or dehydration.
In an enclosed holding environment, too much
moisture content is a condition which can be relieved.
A product achieving extremely high temperatures
in preparation must be allowed to decrease in
temperature before being placed in a controlled
holding atmosphere. If the product is not allowed to
decrease in temperature, excessive condensation will
form increasing the moisture content on the outside
of the product. To preserve the safety and quality
of freshly cooked foods however, a maximum of 1
to 2 minutes must be the only time period allowed
for the initial heat to be released from the product.
Most Halo Heat holding equipment is provided with
a thermostat control between 60° and 200°F (16° to
93°C). If the unit is equipped with vents, close
the vents for moist holding and open the vents for
crisp holding.
OPERATION
HOLDING TEMPERATURE RANGE
MEAT FAHRENHEIT CELSIUS
BEEF ROAST Rare 130°F 54°C
BEEF ROAST Med/Well Done 155°F 68°C
BEEF BRISKET 160° 175°F 71° — 79°C
CORN BEEF 160° 175°F 71° — 79°C
PASTRAMI 160° 175°F 71° — 79°C
PRIME RIB Rare 130°F 54°C
STEAKS Broiled/Fried 140° 160°F 60° — 71°C
RIBS Beef or Pork 160°F 71°C
VEAL 160° 175°F 71° — 79°C
HAM 160° 175°F 71° — 79°C
PORK 160° 175°F 71° — 79°C
LAMB 160° — 175°F 71° 79°C
POULTRY
CHICKEN — Fried/Baked 160° 175°F 71° 79°C
DUCK 160° — 175°F 71° 79°C
TURKEY 160° 175°F 71° 79°C
GENERAL 160° 175°F 71° 79°C
FISH/SEAFOOD
FISH Baked/Fried 160° 175°F 71° 79°C
LOBSTER 160° 175°F 71° 79°C
SHRIMP Fried 160° 175°F 71° 79°C
BAKED GOODS
BREADS/ROLLS 120° 140°F 49° 60°C
MISCELLANEOUS
CASSEROLES 160° 175°F 71° 79°C
DOUGH Proofing 80° 100°F 27° 38°C
EGGS —Fried 150° 160°F 66° 71°C
FROZEN ENTREES 160° 175°F 71° 79°C
HORS D'OEUVRES 160° 180°F 71° 82°C
PASTA 160° 180°F 71° 82°C
PIZZA 160° 180°F 71° 82°C
POTATOES 180°F 82°C
PLATED MEALS 140° 165°F 60°— 74°C
SAUCES 140° — 200°F 60° 93°C
SOUP 140° 200°F 60° 93°C
VEGETABLES 160° 175°F 71° 79°C
THE HOLDING TEMPERATURES LISTED ARE SUGGESTED GUIDELINES ONLY. ALL
FOOD HOLDING SHOULD BE BASED ON INTERNAL PRODUCT TEMPERATURES.
ALWAYS FOLLOW LOCAL HEALTH (HYGIENE) REGULATIONS FOR ALL INTERNAL
TEMPERATURE REQUIREMENTS.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 10
CAUTION
TO PROTECT STAINLESS STEEL
SURFACES, COMPLETELY AVOID
THE USE OF ABRASIVE CLEANING
COMPOUNDS, CHLORIDE BASED
CLEANERS, OR CLEANERS
CONTAINING QUATERNARY SALTS.
NEVER USE HYDROCHLORIC ACID
(MURIATIC ACID) ON STAINLESS
STEEL. NEVER USE WIRE
BRUSHES, METAL SCOURING
PADS OR SCRAPERS.
N
O
W
I
R
E
B
R
U
S
H
E
S
N
O
S
T
E
E
L
P
A
D
S
N
O
S
C
R
A
P
E
R
S
PROTECTING STAINLESS STEEL SURFACES
It is important to guard against corrosion
in the care of stainless steel
surfaces. Harsh, corrosive,
or inappropriate chemicals
can completely destroy the
protective surface layer
of stainless steel. Abrasive
pads, steel wool, or metal implements will abrade
surfaces causing damage to this protective coating
and will eventually result in areas of corrosion.
Even water, particularly hard water that contains
high to moderate concentrations of chloride, will
cause oxidation and pitting that result in rust
and corrosion. In addition, many acidic foods
spilled and left to remain on metal surfaces are
contributing factors that will corrode surfaces.
Proper cleaning agents, materials, and
methods are vital to maintaining the appearance
and life of this appliance. Spilled foods should be
removed and the area wiped as soon as possible
but at the very least, a minimum of once a day.
Always thoroughly rinse surfaces after using a
cleaning agent and wipe standing water as quickly
as possible after rinsing.
CLEANING AGENTS
Use non-abrasive cleaning products designed for
use on stainless steel surfaces. Cleaning agents
must be chloride-free compounds and must not
contain quaternary salts. Never use hydrochloric
acid (muriatic acid) on stainless steel surfaces.
Always use the proper cleaning agent at the
manufacturer's recommended strength.
Contact your local cleaning supplier for
product recommendations.
CLEANING MATERIALS
The cleaning function can usually be accomplished
with the proper cleaning agent and a soft, clean
cloth. When more aggressive methods must be
employed, use a non-abrasive scouring pad on
difficult areas and make certain to scrub with the
visible grain of surface metal to avoid surface
scratches. Never use wire brushes, metal scouring
pads, or scrapers to remove food residue.
CLEANING AND PREVENTATIVE MAINTENANCE
CARE AND CLEANING
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 11
THOROUGHLY CLEAN DAILY:
1. Disconnect unit from power source, and let cool.
2. Remove, cover or wrap, and refrigerate food.
3. Remove drawer pans and clean separately.
The drawer assembly is completely removable.
Remove from the cabinet and clean to prevent a
build-up of food residue from interfering with
the function of the drawer assembly. Regular
cleaning will help prolong the life of these parts.
4. Clean interior metal surfaces
of the unit with a damp, clean
cloth and any good commercial
detergent or grease solvent at
the recommended strength.
Use a plastic scouring pad or
oven cleaner for difficult areas. Rinse carefully to
remove all residue and wipe dry.
NOTE: Avoid the use of abrasive cleaning,
compounds, chloride based cleaners, or
cleaners containing quaternary salts. Never
use hydrochloric acid (muriatic acid) on
stainless steel.
5. Wipe control panel, vents, handles, and gaskets
thoroughly since these areas harbor food debris.
6. Interior can be wiped with a sanitizing solution
after cleaning and rinsing. This solution must
be approved for use on stainless steel food
contact surfaces.
7. To help maintain the protective film coating on
polished stainless steel, clean the exterior of the
unit with a cleaner recommended for stainless
steel surfaces. Spray the cleaning agent on
a clean cloth and wipe with the grain of the
stainless steel.
Always follow appropriate state or local health
(hygiene) regulations regarding all applicable
cleaning and sanitation requirements for
foodservice equipment.
The cleanliness and appearance of this equipment will contribute considerably to
operating efficiency and savory, appetizing food. Good equipment that is kept clean
works better and lasts longer.
CARE AND CLEANING
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
DANGER
AT NO TIME SHOULD THE INTERIOR
OR EXTERIOR BE STEAM CLEANED,
HOSED DOWN, OR FLOODED WITH
WATER OR LIQUID SOLUTION OF
ANY KIND. DO NOT USE WATER JET
TO CLEAN.
SEVERE DAMAGE OR
ELECTRICAL HAZARD
COULD RESULT.
WARRANTY BECOMES VOID IF
APPLIANCE IS FLOODED
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 12
Food fl avor and aroma are usually so closely related
that it is diffi cult, if not impossible, to separate them.
There is also an important, inseparable relationship
between cleanliness and food fl avor. Cleanliness, top
operating effi ciency, and appearance of equipment
contribute considerably to savory, appetizing foods. Good
equipment that is kept clean, works be er and lasts longer.
Most food imparts its own particular aroma and many
foods also absorb existing odors. Unfortunately, during
this absorption there is not distinction between GOOD
and BAD odors The majority of objectionable fl avors and
odors troubling food service operations are caused by
bacteria growth. Sourness, rancidity, mustiness, stale or
other OFF fl avors are usually the result of germ activity.
The easiest way to insure full, natural food fl avor is
through comprehensive cleanliness. This means good
control of both visible soil (dirt) and invisible soil
(germs). A through approach to sanitation will provide
essential cleanliness. It will assure an a ractive
appearance of equipment, along with maximum effi ciency
and utility. More importantly, a good sanitation program
provides one of the key elements in the prevention of
food-borne illnesses.
A controlled holding environment for prepared foods is
just one of the important factors involved in the prevention
of food-borne illnesses. Temperature monitoring and
control during receiving, storage, preparation, and the
service of foods are of equal importance.
The most accurate method of measuring safe temperatures
of both hot and cold foods is by internal product
temperature. A quality thermometer is an eff ective tool for
this purpose, and should be routinely used on all products
that require holding at a specifi c temperature.
A comprehensive sanitation program should focus on
the training of staff in basic sanitation procedures. This
includes personal hygiene, proper handling of raw
foods, cooking to a safe internal product temperature,
nd the routine monitoring of internal temperatures from
receiving through service.
Most food-borne illnesses can be prevented through
proper temperature control and a comprehensive
program of sanitation. Both these factors are important
to build quality service as the foundation of customer
satisfaction. Safe food handling practices to prevent food-
borne illness is of critical importance to the health and
safety of your customers.
HACCP, an acronym for Hazard Analysis (at) Critical
Control Points, is a quality control program of operating
procedures to assure food integrity, quality, and safety.
Taking steps necessary to augment food safety practices
is both cost eff ective and relatively simple. While HACCP
guidelines go far beyond the scope of this manual,
additional information is available by contacting:
CENTER FOR FOOD SAFETY AND APPLIED
NUTRITION FOOD AND DRUG ADMINISTRATION
1-888-SAFEFOOD
INTERNAL FOOD PRODUCT TEMPERATURES
H OT FO OD S
DANGER ZONE 40° TO 140°F (4° TO 60°C)
CRITICAL ZONE 70° TO 120°F (21° TO 49°C)
SAFE ZONE 140° TO 165°F (60° TO 74°C)
CO LD FOOD S
DANGER ZONE ABOVE 40°F (ABOVE 4°C)
SAFE ZONE 36° TO 40°F (2° TO 4°C)
FRO Z E N FO O D S
DANGER ZONE ABOVE 32°F (ABOVE 0°C)
CRITICAL ZONE 0° TO 32°F (-18° TO 0°C)
SAFE ZONE 0°F or below (-18°C or below)
SANITATION
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 13
THERMOSTAT ACCURACY
The electronic thermostat is a precise instrument
and is designed to offer trouble free service. If
you suspect the temperature inside the holding
compartment does not match the temperature
indicated on the digital display, follow the
instructions listed below.
1. Check to make certain the unit voltage matches
the power source. A power source less than
that required to operate the unit will result in
inaccurate temperatures.
2. Verify the temperature inside the holding
compartment with a quality thermal indicator.
a. Completely empty the holding compartment.
b. Make certain the holding cabinet sensor,
located inside the holding compartment, is
completely clean.
c. Suspend the thermal indicator in the center of
the holding compartment.
d. Allow the temperature set on the electronic
thermostat to stabilize for a minimum of one hour
before comparing the digital display with the
reading on the thermal indicator.
DO NOT OPEN THE CABINET DRAWER(S) DURING
THE TEMPERATURE STABILIZATION PERIOD.
If the reading on the thermal indicator does not match
the digital display, there may be a problem with the
air sensor. See troubleshooting guide in this manual;
or call the factory service department for advice.
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
TROUBLESHOOTING
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
SANITATION
This section is provided for the assistance of qualified technicians only and is not intended for use by untrained
or unauthorized service personnel. If your Alto-Shaam® unit is not operating properly, check the following before
calling your Authorized Alto-Shaam Service Agent:
Check main power circuit breaker to the unit and verify that the circuit breaker on the back of the unit is turned
on, if applicable.
Do not attempt to repair or service the unit beyond this point. Contact Alto-Shaam for the nearest authorized
service agent. Repairs made by any other service agents without prior authorization by Alto-Shaam® will
void the warranty on the unit.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 14
TROUBLE SHOOTING - ELECTRONIC CONTROL
INSTALLATION
Code Description Possible Cause
E-10 Cavity air sensor shorted Cavity air sensor reading < 5°F. Verify sensor integrity.
See sensor test instructions below.
E-11 Cavity air sensor open Cavity air sensor reading > 517°F. Verify sensor integrity.
See sensor test instructions below.
E-20 Product probe is shorted
Oven will cook in time only
Product probe reading < 5°F. Verify sensor integrity.
See sensor test instructions below.
E-21 Product probe is open
Oven will cook in time only
Product Probe reading > 517°F. Verify sensor integrity.
See sensor test instructions below.
E-30 Under temperature Unit has not reached (set-point - 25°F) for more than 90 minutes.
E-31 Over temperature
Unit has been higher than 25°F above the maximum cavity set-point for
more than 2 minutes. Note: Holding Cabinets with this error code are
more than 145°F higher than the maximum set-point.
E-50 Temp. measurement error Contact factory.
E-51 Temp. measurement error Contact factory.
E-60 Real time clock error Data set to factory default. Ensure that date and time are correct if applicable.
E-61 Real time clock error Contact factory.
E-64 Clock is not oscillating Contact factory.
E-70 Configuration connector
error (DIP switch)
Refer to wiring diagram for the particular model and ensure dip switches on
the control match the settings called out on the WD. If the dip switch settings
are correct according to the print replace the control.
E-78 Voltage low Voltage below 90 VAC on a 125 VAC unit, or below 190 VAC on a
208-240 VAC unit. Correct voltage.
E-79 Voltage high Voltage over 135 VAC on a 125 VAC unit, or over 250 VAC on a
208-240 VAC unit. Correct voltage.
E-80 EEPROM Error Ensure that all temperatures and times are properly set.
Contact factory if problem persists.
E-81 EEPROM Error Contact factory.
E-82 EEPROM Error Contact factory.
E-83 EEPROM Error Contact factory.
E-85 EEPROM Error All timers, if previously on, are now off. Possible bad EEPROM.
E-86 EEPROM Error Stored HACCP memory corrupted. HACCP Address reset to 1. Possible bad
EEPROM. Contact factory if problem persists.
E-87 EEPROM Error
Stored offsets corrupted. Offsets reset to 0. Control may need a recalibration.
Possible bad EEPROM. Contact factory if problem persists.
E-88 EEPROM Error All timer set-points are reset to 1 minute. Timers, if previously on, are now
off. Possible bad EEPROM.
E-90 Button stuck A button has been held down for >60 seconds. Adjust control. Error will
reset when the problem has been resolved.
E-dS Datakey error Datakey digital signature incompatible. Cycle power, and install compatible
Datakey if error persists.
E-dT Datakey error Datakey incompatible with control. Install compatible Datakey.
E-dU Datakey unplugged Install Datakey and cycle power to control to clear error.
dLto Datalogger has timed out Cycle power. Contact factory if error persists.
dLSD Micro SD card not plugged in Plug in SD card and cycle power. Contact factory if error persists.
Note: If in doubt, always cycle the power to the control and contact factory if the problem persists.
To test probe and air sensor:
Tes t probe and air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale. The
reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs to be replaced.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 15
SERVICE
1
23
4
56
27
2625
22
21
24
10
19
20
16
15
18
17
11 12 13 14
9
7
8
23
SERVICE VIEW - EXTERIOR
500-2D Shown
Part numbers and drawings are subject to change without notice.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 16
MODEL > 500-1D 500-2D 500-3D
ITEM DESCRIPTION PART NO. QTY PART NO. QTY PART NO. QTY
1TOP COVER 1012473 1 1012473 1 1012473 1
2REAR TRIM 1012665 1 1012674 1 1012446 1
3RIVET, BLIND, #44, S/S 28 RI-2100 24 RI-2100 28 RI-2100 30
4GASKET ADHESIVE 0.125 x 0.375 [lin ft] GS-23622 8GS-23622 8GS-23622 8
5BUSHING, STRAIGHT, STRAIN RELIEF BU-3964 1 BU-3964 1 BU-3964 1
6CORDSET, 120V - 5' (1524mm) CD-3232 1 CD-3232 1 CD-3232 1
CORDSET, 208-240V - 8' (2438mm) CD-3551 1 CD-3551 1 CD-3551 1
CORDSET, 230V - 8' (2438mm) CD-3922 1 CD-3922 1 CD-3922 1
7HI-LIMIT PROTECTION COVER 1003936 1 1003936 1 1003936 1
8SCREW, M4-0.7X6MM PHIL SC-22271 2SC-22271 2SC-22271 2
9HI-LIMIT THERMOSTAT TT-33476 1TT-33476 1TT-33476 1
10 INNER BACK PANEL 1012667 1 1012673 1 1012439 1
11 BRACKET, SENSOR MOUNTING 1008272 1 1008272 1 1008272 1
12 SENSOR, MOUNTING BLOCK BK-27878 1BK-27878 1BK-27878 1
13 PROBE, TEMPERATURE SENSOR PR-34494 1PR-34494 1PR-34494 1
14 SCREW, 6-32 X 1/2", NC PHIL, FLAT SC-2239 2SC-2239 2SC-2239 2
15 ELEMENT, 320W, FOIL PAD HEATER EL-29875 1 EL-29875 2 EL-29875 2
16 OUTER CASING 1012664 1 1012671 1 1012445 1
17 BEARING, DRAWER WARMER BG-24890 2 BG-24890 4 BG-24890 6
18 SCREW,1/4-20 x 1-1/8" FLAT HD, BEARING MOUNT SC-25018 2SC-25018 4SC-25018 6
19 DRAWER FRAME ASSEMBLY, COMPLETE 5013915 1 5013915 2 5013915 3
20 PAN, FULL SIZE, 20-3/4" x 12-3/4" x 6" PN-25088 1PN-25088 2PN-25088 3
21 SWITCH, ROCKER, 125-277V, 20A SW-34769 1SW-34769 1SW-34769 1
22 OVERLAY, CONTROL PANEL PE-29685 1PE-29685 1PE-29685 1
23 CONTROL CC-34970 1 CC-34970 1 CC-34970 1
24 FRONT TRIM STUD ASSEMBLY 5014253 1 5014255 1 5013914 1
25 ELECTRIC CHASSIS SPOT 5014441 1 5014441 1 5014441 1
26 CONNECTOR-5 CONDUCTOR CR-34646 2CR-34646 2CR-34646 2
27 T-BLOCK BK-3019 1BK-3019 1BK-3019 1
28* BUSHING, 3/8" BLACK HOLE BU-3419 1 BU-3419 1 BU-3419 1
29* CONNECTOR, #12 FERRULE CR-34830 3CR-34830 3CR-34830 3
30* INSULATION IN-2003 5IN-2003 5IN-2003 5
31* NUT, HEX #8-32 NU-2296 3 NU-2296 3 NU-2296 3
32* NUT, 6-32 HEX, S/S NU-2361 4 NU-2361 4 NU-2361 4
33* PLUG, 3/8" HOLE PG-25574 1PG-25574 1PG-25574 1
34* SCREW, 10-32" X 1/4" PAN HD GROUND SC-2190 1SC-2190 1SC-2190 1
35* SCREW, 6-32 X 1-1/4" ROUND HD SC-2365 2SC-2365 2SC-2365 2
36* SCREW, 8-32 x 1/4" PHIL SC-2459 4SC-2459 4SC-2459 4
37* WASHER, 6-32, FLAT, NYLON WS-23148 1WS-23148 1WS-23148 1
38* WASHER, INT. LOCK WS-2467 1WS-2467 1WS-2467 1
SERVICE
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
DANGER
LOCK-OUT OR POST
BREAKER PANEL UNTIL
SERVICE WORK HAS
BEEN COMPLETED.
SERVICE VIEW - EXTERIOR PARTS LIST
*not shown
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 17
SERVICE
3
4
5
1
2
12
11
10
6
13
8
7
9
SERVICE VIEW - DRAWER ASSEMBLY (5013915)
500-D
Part numbers and drawings are subject to change without notice.
ITEM DESCRIPTION PART NO. QTY
1WASHER, 1/4" LOCK WS-2294 2
2NUT 1/4-20 NC ACORN #18-8 S/S NU-2187 2
3PAN SUPPORT, DRAWER WARMER 5013916 1
4BEARING, DRAWER WARMER BG-24890 2
5SCREW, 1/4-20 x 1-1/8" FLAT HD SC-25018 2
6STUD, SHOULDER, SHORT, S/S ST-2546 4
7DRAWER FRAME 1012476 1
8STUD, S/S PIVOT ST-25019 4
9NUT, INSERT THREADED, 1/4-20 NU-24613 4
10 DRAWER FRONT SPOT 5013917 1
11 INSULATION, 7.13" X 16" X .50" THICK IN-2003 1
12 OUTER DRAWER 16467 1
13 RIVET, BLIND, #44, S/S RI-2100 4
Item #9 must be ordered
when installing item #10
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 18
SERVICE
4
6
5
1
2
11
12
10
17
1819
20
23
24
25
26
27 28
29
21
22
13 14 15 16
3
9
7
8
SERVICE VIEW - EXTERIOR
500-1DN Shown
Part numbers and drawings are subject to change without notice.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 19
SERVICE
MODEL > 500-1DN 500-2DN 500-3DN
ITEM DESCRIPTION PART NO. QTY PART NO. QTY PART NO. QTY
1TOP COVER 1012779 1 1012779 1 1012779 1
2GASKET ADHESIVE 0.125 x 0.375 [lin ft] GS-23622 8GS-23622 8GS-23622 8
3BUSHING, STRAIGHT, STRAIN RELIEF BU-3964 1 BU-3964 1 BU-3964 1
4REAR TRIM 1012796 1 1012791 1 1012781 1
5CORDSET, 120V - 5' (1524mm) CD-3232 1 CD-3232 1 CD-3232 1
CORDSET, 208-240V - 8' (2438mm) CD-3551 1 CD-3551 1 CD-3551 1
CORDSET, 230V - 8' (2438mm) CD-3922 1 CD-3922 1 CD-3922 1
6RIVET, BLIND, #44, S/S 28 RI-2100 24 RI-2100 28 RI-2100 30
7HI-LIMIT PROTECTION COVER 1003936 1 1003936 1 1003936 1
8SCREW, M4-0.7X6MM PHIL SC-22271 2SC-22271 2SC-22271 2
9HI-LIMIT THERMOSTAT TT-33476 1TT-33476 1TT-33476 1
10 INNER BACK PANEL 1012797 1 1012790 1 1012778 1
11 T-BLOCK BK-3019 1BK-3019 1BK-3019 1
12 CONNECTOR-5 CONDUCTOR CR-34646 2CR-34646 2CR-34646 2
13 BRACKET, SENSOR MOUNTING 1008272 1 1008272 1 1008272 1
14 SENSOR MOUNTING BLOCK BK-27878 1BK-27878 1BK-27878 1
15 TEMPERATURE SENSOR PR-34494 1PR-34494 1PR-34494 1
16 SCREW, 6-32 X 1/2", NC PHIL, FLAT SC-2239 2SC-2239 2SC-2239 2
17 OUTER CASING 1012795 1 1012792 1 1012777 1
18 ELEMENT, 320W, FOIL PAD HEATER EL-29875 2 EL-29875 2
ELEMENT, 250W, FOIL PAD HEATER EL-29738 1 — — — —
19 BEARING, DRAWER WARMER BG-24890 2 BG-24890 4 BG-24890 6
20 SCREW, 1/4-20 x 1-1/8" FLAT HD, BEARING MOUNT SC-25018 2SC-25018 4SC-25018 6
21 DRAWER FRAME ASSEMBLY, COMPLETE 5014435 1 5014435 2 5014435 3
22 PAN, FULL SIZE, 20-3/4" x 12-3/4" x 6" PN-25088 1PN-25088 2PN-25088 3
23 SWITCH, ROCKER,125-277V, 20A SW-34769 1SW-34769 1SW-34769 1
24 OVERLAY, CONTROL PANEL PE-29686 1PE-29686 1PE-29686 1
25 CONTROL CC-34970 1 CC-34970 1 CC-34970 1
26 FRONT TRIM STUD ASSEMBLY 5014432 1 5014430 1 5014427 1
27 WASHER, 6-32 FLAT, NYLON WS-23148 4WS-23148 4WS-23148 4
28 NUT, 6-32, HEX, S/S NU-2361 4 NU-2361 4 NU-2361 4
29 ELECTIC CHASSIS SPOT 5014441 1 5014441 1 5014441 1
30* BUSHING, 3/8" BLACK HOLE BU-3419 1 BU-3419 1 BU-3419 1
31* CONNECTOR, #12 FERRULE CR-34830 3CR-34830 3CR-34830 3
32* INSULATION IN-2003 5IN-2003 5IN-2003 5
33* NUT, HEX #8-32 NU-2296 3 NU-2296 3 NU-2296 3
34* NUT, 6-32 HEX, S/S NU-2361 4 NU-2361 4 NU-2361 4
35* PLUG, 3/8" HOLE PG-25574 1PG-25574 1PG-25574 1
36* SCREW, 10-32" X 1/4" PAN HD GROUND SC-2190 1SC-2190 1SC-2190 1
37* SCREW, 6-32 X 1-1/4" ROUND HD SC-2365 2SC-2365 2SC-2365 2
38* SCREW, 8-32 x 1/4" PHIL SC-2459 4SC-2459 4SC-2459 4
39* WASHER, 6-32, FLAT, NYLON WS-23148 1WS-23148 1WS-23148 1
40* WASHER, INT. LOCK WS-2467 1WS-2467 1WS-2467 1
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
DANGER
LOCK-OUT OR POST
BREAKER PANEL UNTIL
SERVICE WORK HAS
BEEN COMPLETED.
SERVICE VIEW - EXTERIOR PARTS LIST
*not shown
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 20
SERVICE
7
6
5
9
10
12
14
13
4
1
8
3
2
11
SERVICE VIEW - DRAWER ASSEMBLY (5014435)
500-DN
Part numbers and drawings are subject to change without notice.
Item #10 must be ordered
when installing item #11
ITEM DESCRIPTION PART NO. QTY
1RAIL, PAN, LEFT-HAND 1014652 1
RAIL, PAN, LEFT-HAND (prior to 4/1/13) 1014370 1
2LOCK WASHER 1/4" WS-2294 2
3NUT, 1/4-20 NC ACORN #18-8 S/S NU-2187 2
4RAIL, PAN, RIGHT-HAND 1014654 1
RAIL, PAN, RIGHT-HAND (prior to 4/1/13) 1014391 1
5DRAWER FRAME, SPOT 5014439 1
6BEARING, DRAWER WARMER BG-24890 2
7SCREW, 1/4-20 x 1-1/8" FLAT HD SC-25018 2
8RIVET, SEALED RI-27108 2
9STUD, S/S PIVOT ST-25019 4
10 NUT, INSERT THREADED, 1/4-20 NU-24613 4
11 DRAWER, INNER, WITH HANDLE 1012802 1
12 RIVET, BLIND, #44, S/S RI-2100 4
13 OUTER DRAWER, NARROW 1012804 1
14 INSULATION, 7.13” X 16” X .50” THICK IN-2003 1
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 21
SERVICE
6
5
8
7
4
3
12
10
9
SERVICE VIEW - ELECTRICAL
Part numbers and drawings are subject to change without notice.
ITEM DESCRIPTION PART NO. QTY
1BUSHING, 3/8" HOLE BU-3419 1
2ELECTRIC CHASSIS 5014441 1
3WASHER, INT. LOCK WS-2467 1
4SCREW, 10-32 X 1/4 PAN HD GROUND SC-2190 1
5CONNECTOR, #16 FERRULE CR-34828 3
6CORDSET, 120V - 5' (1524mm) CD-3232 1
CORDSET, 208-240V - 8' (2438mm) CD-3551 1
CORDSET, 230V - 8' (2438mm) CD-3922 1
7T-BLOCK BK-3019 1
8SCREW, 6-32 X 1-1/4" ROUND HD SC-2365 2
9SPACER, SNAP-IN 7/16" SP-29392 6
10 CONTROL CC-34970 1
DANGER
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
DANGER
LOCK-OUT OR POST
BREAKER PANEL UNTIL
SERVICE WORK HAS
BEEN COMPLETED.
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 22
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 23
MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual 24
TRANSPORTATION DAMAGE and CLAIMS
All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments
become the property of the consignee.
Should damage occur in shipment, it is a matter between the carrier and the consignee. In such cases,
the carrier is assumed to be responsible for the safe delivery of the merchandise, unless negligence can be
established on the part of the shipper.
1. Make an immediate inspection while the equipment is still in the truck or immediately after it is moved to the receiving area.
Do not wait until after the material is moved to a storage area.
2. Do not sign a delivery receipt or a freight bill until you have made a proper count and inspection of all merchandise received.
3. Note all damage to packages directly on the carrier’s delivery receipt.
4. Make certain the driver signs this receipt. If he refuses to sign, make a notation of this refusal on the receipt.
5. If the driver refuses to allow inspection, write the following on the delivery receipt:
Driver refuses to allow inspection of containers for visible damage.
6. Telephone the carrier’s office immediately upon finding damage, and request an inspection. Mail a written confirmation of the
time, date, and the person called.
7. Save any packages and packing material for further inspection by the carrier.
8. Promptly file a written claim with the carrier and attach copies of all supporting paperwork.
We will continue our policy of assisting our customers in collecting claims which have been properly filed and actively pursued.
We cannot, however, file any damage claims for you, assume the responsibility of any claims, or accept deductions in payment
for such claims.
LIMITED WARRANTY
Alto-Shaam, Inc. warrants to the original purchaser only that any original part that is found to be defective in material or workmanship will, at
Alto-Shaam's option, subject to provisions hereinafter stated, be replaced with a new or rebuilt part.
The original parts warranty period is as follows:
For the refrigeration compressor on Alto-Shaam Quickchillers, five (5) years from the date of installation of appliance.
For the heating element on Halo Heat® cooking and holding ovens, as long as the original purchaser owns the oven. This
excludes holding only equipment.
For all other original parts, one (1) year from the date of installation of appliance or fifteen (15) months from the shipping date, whichever
occurs first.
The labor warranty period is one (1) year from the date of installation or fifteen (15) months from the shipping date, whichever occurs first.
Alto-Shaam will bear normal labor charges performed during standard business hours, excluding overtime, holiday rates or any
additional fees.
To be valid, a warranty claim must be asserted during the applicable warranty period. This warranty is not transferable.
THIS WARRANTY DOES NOT APPLY TO:
1. Calibration.
2. Replacement of light bulbs, door gaskets, and/or the replacement of glass due to damage of any kind.
3. Equipment damage caused by accident, shipping, improper installation or alteration.
4. Equipment used under conditions of abuse, misuse, carelessness or abnormal conditions, including but not limited to, equipment
subjected to harsh or inappropriate chemicals, including but not limited to, compounds containing chloride or quaternary salts, poor water
quality, or equipment with missing or altered serial numbers.
5. Damage incurred as a direct result of poor water quality, inadequate maintenance of steam generators and/or surfaces affected by water
quality. Water quality and required maintenance of steam generating equipment is the responsibility of the owner/operator.
6. Damage caused by use of any cleaning agent other than Alto-Shaam's Combitherm® Cleaner, including but not limited to damage due to
chlorine or other harmful chemicals. Use of Alto-Shaam's Combitherm® Cleaner on Combitherm® ovens is highly recommended.
7. Any losses or damage resulting from malfunction, including loss of product, food product, revenue, or consequential or incidental
damages of any kind.
8. Equipment modified in any manner from original model, substitution of parts other than factory authorized parts, removal of any parts
including legs, or addition of any parts.
This warranty is exclusive and is in lieu of all other warranties, express or implied, including the implied
warranties of merchantability and fitness for a particular purpose. In no event shall Alto-Shaam be liable for
loss of use, loss of revenue or profit, or loss of product, or for any indirect, special, incidental, or consequential
damages. No person except an officer of Alto-Shaam, Inc. is authorized to modify this warranty or to incur on
behalf of Alto-Shaam any other obligation or liability in connection with Alto-Shaam equipment.
RECORD THE MODEL AND SERIAL NUMBER OF THE APPLIANCE FOR EASY REFERENCE.
ALWAYS REFER TO BOTH MODEL AND SERIAL NUMBER IN ANY CONTACT WITH ALTO-SHAAM REGARDING THIS APPLIANCE.
Model: ______________________________________________ Date Installed: ______________________________________________________
Voltage: ______________________________________________ Purchased From: ___________________________________________
Serial Number: _____________________________________________________________________________________________________________
W164 N9221 Water Street P.O. Box 450 Menomonee Falls, Wisconsin 53052-0450 U.S.A.
PHONE: 262.251.3800 • 800.558-8744
USA/CANADA
FAX: 262.251.7067 • 800.329.8744
U.S.A. ONLY
www.alto-shaam.com
PRINTED I N U.S.A.
Effective November 1, 2012

Navigation menu