Andrew Wireless System IONM8PS ION-M Remote Unit for cellular systems User Manual Installation Instruction
Andrew Wireless System ION-M Remote Unit for cellular systems Installation Instruction
Contents
- 1. Installation Instruction
- 2. User Manual
Installation Instruction
Installation Instruction The Remote Unit, Extension Unit or Master Unit has to be mounted by proffessionel / special trained installer. 1.1. MECHANICAL INSTALLATION 1.1.1. General Read the health and safety warnings in chapter 1.3 Health and Safety Warnings. 1. Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the manufacturer are not met. 2. It is strongly recommended to install the unit vertically. If a different installation of the remote unit is required, please contact customer service for further information. 3. It is recommended only to use the mounting hardware delivered by the manufacturer. If different mounting hardware is used, the specifications for stationary use of the remote unit must not be exceeded. ď Note: Exceeding the specified load limits may cause the loss of warranty! 4. The unit is considerably heavy. Make sure that a suitable mounting surface is used. Ensure there is adequate manpower to handle the weight of the system. 5. Due to power dissipation, the remote unit may reach a very high temperature. Ensure sufficient airflow for ventilation. Above and below the unit a minimum distance of 300 mm to ceiling, floor, etc. has to be kept. Also observe the instructions in the individual mounting procedures. 6. For outdoor installations, the pre-mounted front cover must be installed. 7. For indoor installations where the ambient temperature can reach above 40°C, the cover has to be removed. 8. When connecting and mounting the cables (RF, optical, mains, ...) ensure no water can penetrate into the unit through these cables. If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the remote unit. 1.2. ELECTRICAL INSTALLATION 1.2.1. General Read the health and safety warnings in chapter 1.3 Health and Safety Warnings. 1. This unit contains dangerous voltages. Loss of life, severe personal injury or property damage can be the result if the instructions contained in this manual are not followed. 2. It is compulsory to ground the unit before connecting power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 3. Although the Remote Unit is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the antenna connectors of the Remote Unit for protection against atmospheric discharge. In areas with strong lightning it is strongly recommended to insert additional lightning protection. 4. If the power supply connector of the Remote Unit is not easily accessible, a disconnect device in the power circuit must be provided within easy reach. 5. Before connecting or disconnecting the power supply connector at the Remote Unit, ensure that power supply is disconnected. 6. Make sure that an appropriate circuit breaker and an overcurrent limiting device are connected between power supply and Remote Unit. 7. A connection of power supply to a power socket requires the power socket to be nearby the Remote Unit. 8. Incorrectly wired connections can destroy electrical and electronic components. 9. To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V (see electrochemical contact series). 10. It is sufficient to tighten the N-antenna connector hand-screwed. Any use of a tool (e.g. pair of pliers) might cause damage to the connector and thus lead to malfunctioning of the Remote Unit. 11. For unstabilized electric networks which frequently generate spikes, it is advised to use a voltage limiting device. 12. The unit complies with the surge requirement according to EN 61000-4-5 (fine protection); however, it is recommended to install an additional medium (via local supply connection) and/or coarse protection (external surge protection) depending on the individual application in order to avoid damage caused by overcurrent. 13. Observe the labels on the front panels before connecting or disconnecting any cables. 1.3. HEALTH AND SAFETY WARNINGS 1. Only suitably qualified personnel is allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 2. Read and obey all the warning labels attached to the unit. Make sure that the warning labels are kept in a legible condition and replace any missing or damaged labels. 3. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 4. Keep operating instructions within easy reach and make them available to all users. 5. It is the responsibility of the network provider to implement prevention measures to avoid health hazards which may be associated to radiation from the antenna(s) connected to the unit. 6. Please note for a Class A digital device or peripheral: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 7. Make sure, access is restricted to qualified personnel. 8. Only licence holders for the respective frequency range are allowed to operate this unit. 9. Corresponding local particularities and regulations must be observed. For national deviations please refer to the respective documents included in the manual CD delivered. 10. Use this equipment only for the purpose specified by the manufacturer. Do not carry out any modifications or fit any spare parts which are not sold or recommended by the manufacturer. This could cause fires, electric shock or other injuries. 11. Due to power dissipation, the repeater may reach a very high temperature. Do not operate this equipment on or close to flammable materials. 12. Before opening the unit, disconnect power supply. 13. ESD precautions must be observed! Before commencing maintenance work, use the available grounding system to connect ESD protection measures. 14. This unit complies with European standard EN60950. 15. Make sure the repeater settings are according to the intended use (see also product information of manufacturer) and regulatory requirements are met. 16. Although the repeater is internally protected against overvoltage, it is strongly recommended to earth the antenna cables close to the repeaterâs antenna connectors for protection against atmospheric discharge. 17. Laser radiation! Do not stare into the beam; do not view it directly or with optical instruments.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Frank Futter Comments : Company : Andrew Corporation Create Date : 2012:02:08 15:56:38+01:00 Modify Date : 2012:02:08 15:56:41+01:00 Source Modified : D:20120208145614 Subject : Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : Acrobat PDFMaker 9.1 für Word Metadata Date : 2012:02:08 15:56:41+01:00 Producer : Acrobat Distiller 9.4.6 (Windows) Keywords : Format : application/pdf Creator : Frank Futter Title : Installation Instruction Description : Document ID : uuid:e7e8165e-c933-42d3-badc-a1f3a62db4bf Instance ID : uuid:036ae907-f45c-4cf0-b1d5-821d12c4aa3c Page Layout : OneColumn Page Count : 4EXIF Metadata provided by EXIF.tools