Draft 01.01 June 2000
CTR 28-07 GHz MMIC
Quick Reference Guide
Product Overview
The CTR 28-07 MMIC (NTVG16CA) outdoor transceiver is a customer premise
transceiver designed to operate in various Receiver (Rx) and Transmitter (Tx)
frequency bands. It is a Nortel Networks Reunion product that operates in conjunction with base station products, as well as customer premise products. It is
compatible with Reunion’s Release 1.2 and 1.3 equipment.
CTR 28-07M Transceiver
Figure 1: CTR 28M Block Diagram
Tx IF/DC Input
Lightening
Protector
Tx IF Input
Test Port
Rx IF
Output
Test Port
Rx IF Output
Lightening
Protector
Tx RF Output/
Rx RF Input
(Test Point ‘A’)
Transceiver
Section
2
CTR 28-07 MMIC Specification
Table 1: CTR 28-07M Technical Specifications
TX
IF Input
RF Output
Frequency Range 28-07M
500-650 MHz
28.20-28.35 GHz
Output Level (P1 dB)
≥23 dBm, -40° to +55° C
Output Level (IP3)
+31.0 dBm
Input Impedance
50 Ohms
Input/Output Connector
N-Type Female
N/A
Gain (not including antenna)
32.0 ±0.6 dB
Gain Variation
±5.0 dB over all conditions
Gain Flatness
±1.9 dB over bandwidth
Frequency Stability
<±4 ppm over all conditions
Noise Power
-115 dBm/Hz
TX Test Port
SMA female
TX IF Test Port Coupling
-16±1 dB
Antenna
CTR
Frequency
27.5-28.31.3 GHz
Frequency Band
2731
Gain
36.2 dBi, minimum
Polarity
Cross Pole (dual polarization)
Beam Width (azimuth)
Beam Width (elevation)
2.5±TBD°, minimum
2.5±TBD°, minimum
Cross-Polarization Discrimination
> 30.0 dB
Diameter
14" (35 cm)
411-1333-921 Draft 01.01 June 2000
3
RX
RF Input
IF Output
Frequency Range 28-07M
29.10-29.25 GHz
250-400 MHz
Input/Output Connector
N/A
N-Type Female
Output Impedance
50 Ohms
Gain (not including antenna)
28±0.6 dB, minimum
Gain Variation
±5.0 dB over all conditions
Gain Flatness
±1.9 dB over bandwidth
Frequency Stability
<±4 ppm,over all conditions
Noise Figure
≤ 7.2 dB, maximum
LO Leakage
-35 dBm, maximum
RX Test Port
SMA female
RX IF Test Port Coupling
-14±1 dB
Power Requirements
CTR
Input Voltage
-48 VDC, 3.5A. max
diplexed with TX cable
Input Current
<1.5 Amp
Input Power
55 Watts, maximum
Environmental
CTR
Humidity
100% condensing
Altitude
10,000 feet
Wind Resistance
50m/second on all surfaces
Operating Temperature
-40° to +55°C
Storage Temperature Range
-55° to +70°C
Mechanical
CTR
Size (Length x Width)
10.55" x 11.63" (26.4 x 29 cm)
Weight without brackets
25 lbs. (11.1 KG)
CTR 28-07 GHz MMIC Quick Reference Guide
Converted Frequency Formula
Use the following formula to calculate the converted frequency:
TX: ƒRF OUT (GHz) = 28.85 (GHz) - ƒIF IN (MHz)
RX: ƒIF OUT (MHz) = ƒRF INPUT (GHz) - 28.85 (GHz)
Note: The antenna has an option of a hydrophobic coating that can help to
reduce ice build-up effect.
Note: Vent holes are covered with a GoretexTM patch.
Note: The transceiver mounts to a vertical pole of 2.5” to 4.5” outside diameter. It has a range of motion of 90° over and -60° under horizon. The bases of
the antenna mount can rotate ±180°.
Note: The module connector is N-Type female. The receive IF input/output
cables present a male N-Type connector. The Tx IF and the Rx IF test ports
are SMA-Type female.
Technical Assistance Contact Information
In case additional technical assistance is required, or the transceiver unit is
damaged upon receipt, contact Nortel Networks.
Nortel Networks Broadband Wireless Access (BWA) provides 24-hour customer
service and technical support to ensure your service operation is trouble-free.
If you have questions or need technical support, contact Nortel Networks
Broadband Wireless Access at the following telephone numbers:
• In the USA and Canada, call 972-BWA-ETAS/972-292-3827
Information is subject to change without notice.
Nortel reserves the right to make changes in
design or components as progress in engineering
and manufacturing may warrant.
© 2000 Northern Telecom Ltd.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 1910:00:60 90:81:31
Producer                        : Acrobat Distiller 3.01 for Windows
Title                           : Untitled Document
Creator                         : FrameMaker 5.5.3L15a
Modify Date                     : 2000:06:09 10:34:41
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: AB6CTR2807M

Navigation menu