Axxcelera Broand Wireless EX-F058 AB-Access EXTENDER User Manual User Installation Manual part 1
Axxcelera Broadband Wireless, Inc. AB-Access EXTENDER User Installation Manual part 1
Contents
User Installation Manual part 1
AB-ACCESS U-NII PRODUCT INSTALLATION MANUAL SYSTEM for Subscriber Units, Base Stations, Access Points and AB-Access Extender Units Internal DRAFT Copy Document Number: ABA-U-NII-PIM-3 (part1 – chapters 1 to 6) May 2001 Company Proprietary AB-ACCESS SYSTEM PREFACE Preface AB-Access™ System technology enables high-speed, broadband Internet access for fast data transmission, full streaming video, real-time video conferencing, and web surfing. Adaptive Broadband’s wireless point-to-multipoint and point-to-point solutions (AB-Access Extender) for fixed networks enables our customers to easily leap-over existing infrastructure, making the initial investment significantly lower than that required for wired alternatives. Adaptive Broadband’s, patent pending, Packet-on-Demand technology delivers up to 10 times the effective Internet data throughput of existing network configurations. Our technology provides a last-mile solution, when deployed between networks and business/residential Internet users. AB-Access System’s low-cost, wireless infrastructure means that a complete network can be installed in days or weeks, instead of the typical months or years. Since AB-Access architecture is highly scalable, our customers’ wireless network can grow as quickly as their business grows or as bandwidth needs evolve. This manual explains how to install the U-NII AB-NetAccess software and perform network management tasks using GUI-based applications (the AB-NetAccess client software). This software can run on any IP client on your network and is controlled by the main Element Management System (EMS) application, the AB-NetAccess server software, which resides on a single server on your IP network. The main tasks covered in this manual are configuring and managing network elements, such as Base Stations, Subscriber Units, Access Points, AB-Access Extender Units, Anchor Switches, and Control Servers. Definitions of all the terms and abbreviations used in this manual can be found in the Glossary at the end of this manual. Proprietary Notice The information contained within this manual was originated by and is the property of Adaptive Broadband Corporation. Adaptive Broadband Corporation reserves all patent proprietary design, manufacturing, reproduction use, and sales rights thereto, and to any articles disclosed therein, except to the extent rights are expressly granted to others. The foregoing does not apply to vendor proprietary parts. To allow for the introduction of design improvements, specifications are subject to change without notice. Intended Audience This guide is aimed at qualified AB-Access System installers. Installers should have experience in radio equipment installations and aspects of hardware and software networks. Installers for AB-Access Extender should be professionally qualified to install radio equipment. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 Company Proprietary Related Documentation For more information, refer to one or more of the following documents: • • • • • AB-Access U-NII Configuration & User’s Guide – Covers AB-Access components, architectures, configuration, and troubleshooting AB-Access U-NII System Functional Specification – Lists the specifications of the various components of an AB-Access network AB-Access U-NII Product Installation Manual – Explains how to install AB-Access Subscriber Units and Base Stations AB-Access Command Line Interface (CLI) Manual – Describes configuration, operational, and diagnostic capabilities for Subscriber Units and Base Stations. AB-Access Software Release Notes – Describes updates and changes to the latest software and known product issues. Customer Documentation Questions/Comments Adaptive Broadband’s Technical Publications Department is constantly reviewing its ABAccess System(s) documentation to make the information as clear, accurate, and user-friendly as possible. We would like to receive any comments or questions you have about this manual. Please send an e-mail to: techpubs@adaptivebroadband.com with your views on anything in this manual that you think needs to be clarified or structured differently. Additionally, please let us know if you found this manual useful and its information easy to understand. Notice While every reasonable effort has been made to ensure the accuracy of this manual, product improvements may result in minor differences between the manual and the product shipped to you. If you have any questions or need an exact specification for a product, please contact Adaptive Broadband’s Customer Service Team at our toll free number: TBD. In addition, documentation updates can often be found on our Web site at: www.adaptivebroadband.com. Adaptive Broadband Corp. TBD: New Tech Pubs Address, Phone and FAX information to be inserted USA Tel: TBD FAX: TBD Copyright 2001 Adaptive Broadband Corp. AB-ACCESS SYSTEM ADAPTIVE BROADBAND PRODUCT WARRANTY Adaptive Broadband U-NII Product Installation Manual 05/29/2001 ii Company Proprietary Product Manufactured by ADAP: a. Products manufactured by ADAP are warranted against defects in material and workmanship for a period of one (1) year from date of delivery as evidenced by ADAP's packing slip or other transportation receipt. b. ADAP's sole responsibility under this warranty will be to either repair or replace, at its option, any component which fails during the applicable warranty period because of a defect in material or workmanship, provided Buyer has promptly reported same to ADAP in writing. All replaced products and parts will become ADAP's property. c. ADAP will honor the warranty at the repair facility designated by ADAP. It is Buyer's responsibility to return, at its expense, the allegedly defective product to ADAP. Buyer must obtain a Return Material Authorization (RMA) number and shipping instructions from ADAP prior to returning any product under warranty. Transportation charges for the return of the product to Buyer will be paid by ADAP within the United States. For all other locations, the warranty excludes all costs of shipping, customs clearance and other related charges. If ADAP determines that the product is not defective within the terms of this warranty, Buyer will pay ADAP all costs of handling, transportation and repairs at the then prevailing repair rates. d. All the above warranties are contingent upon proper use of the product. These warranties will not apply (i) if adjustment, repair, or product or parts replacement is required because of accident, unusual physical, electrical or electromagnetic stress, neglect, misuse, failure of electric power, environmental controls, transportation, failure to maintained properly or otherwise in accordance with ADAP specifications, or abuses other than ordinary use; (ii) if the product has been modified by Buyer or has been repaired or altered outside ADAP's repair facility, unless ADAP specifically authorizes such repairs or alterations in each instance; or (iii) where ADAP serial numbers, warranty data or quality assurance decals have been removed or altered. e. No person, including any system provider, agent or representative of ADAP is authorized to assume for ADAP any other liability on its behalf except as set forth herein. If any payment is due ADAP for services performed hereunder, it will be subject to the same payment terms as the original purchase. Products Manufactured By Others: For products not manufactured by ADAP, the original manufacturer's or licensor’s warranty will be assigned to Buyer to the extent permitted by the manufacturer or licensor and is in lieu of any other warranty, expressed or implied. For warranty information on a specific product, a written request should be made to ADAP. All Products: Adaptive Broadband U-NII Product Installation Manual 05/29/2001 iii Company Proprietary THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES, OBLIGATIONS, AND LIABILITIES ON THE PART OF ADAP. EXCEPT FOR THE EXPRESS WARRANTIES STATED HEREIN, ADAP DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HEREUNDER, INCLUDING, WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ADAP WILL HAVE NO RESPONSIBILITY FOR ANY PARTICULAR APPLICATION MADE OF ANY EQUIPMENT. Any description of equipment, whether in writing or made orally by ADAP or its agents, specification sheets, models, bulletins, drawings, or similar materials used in connection with Buyer’s order are for the sole purpose of identifying the equipment and will not be construed as an express warranty. Any suggestions by ADAP or its agents regarding use, application or suitability of the equipment will not be construed as an express warranty. No warranties may be implied from any course of dealing or usage of trade. Buyer agrees that the exclusion of all warranties, other than those expressly provided herein, is reasonable. Additional Terms: All transactions between ADAP and Buyer and all matters related to them are and will be governed solely by ADAP’s Standard Terms and Conditions of Sale as may be in effect from time to time, unless otherwise expressly agreed to by ADAP in advance and in writing. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 iv Company Proprietary AB-ACCESS SYSTEM PRODUCT RETURN PROCEDURE PRODUCT RETURN PROCEDURE It is a requirement of Adaptive Broadband Corporation that any product returned for repair or replacement must first be authorized by Adaptive Broadband and assigned a Return Material Authorization (RMA) number. The repair site will not repair or replace any defective unit without an RMA number. To receive authorization to return a defective product and obtain an RMA number, call Adaptive Broadband’s Technical Support at our toll free number: TBD. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 Company Proprietary PLEASE READ THESE SAFETY PRECAUTIONS! RF Energy Health Hazard The radio equipment described in this guide uses radio frequency transmitters. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come in close proximity to the front of the antenna while the transmitter is operating. Protection from Lightning Article 810 of the US National Electric Department of Energy Handbook 1996 specifies that radio and television lead-in cables must have adequate surge protection at or near the point of entry to the building. The code specifies that any shielded cable from an external antenna must have the shield directly connected to a 10 AWG wire that connects to the building ground electrode. FCC Notice, USA The AB-Access Subscriber Unit complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: • • This device may not cause harmful interference. This device must accept any interference received including interference that may cause undesired operation. This device is specifically designed to be used under Part 15, Subpart E of the FCC Rules and Regulations. Any unauthorized modification or changes to this device without the express approval of Adaptive Broadband Corporation may void the user’s authority to operate this device. Furthermore, this device is intended to be used only when installed in accordance with the instructions outlined in this manual. Failure to comply with these instructions may also void the user’s authority to operate this device and/or the manufacturer’s warranty Adaptive Broadband U-NII Product Installation Manual 05/29/2001 vi Company Proprietary Conditions specific to AB-Access Extender: AB-Access Extender complies with Part 15 of the FCC rules. The device is specifically designed to be used under Part 15, Sub-part E of the FCC rules and regulations. Operation is subject to following conditions: • • • • • The device to utilize a fixed mount antenna, for use on a permanent outdoor structure. The device to be installed by qualified installation/deployment personnel, and a minimum of 1.5 meters of separation must exist between the device and persons, when the device is operating. The device installers and operators should be aware of the transmitter operating conditions, specified in the AB-Extender installation manual and other associated user documentation, as well as the antenna co-location requirements of Part 1.1307 (b) (3), of FCC rules, pertaining to RF exposure. The device may not cause harmful interference. The device must accept interference received, including interference that may cause undesired operation. The device is intended to be used only when installed in accordance with instructions outlined in this manual. Failure to comply with these instructions may void the user's authority to operate this device and/or the manufacturer's warranty. Furthermore, any unauthorized modification or changes to this device without the express approval of Adaptive Broadband Corporation may also void the user's authority to operate this device. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 vii AB-ACCESS SYSTEM Company Proprietary Table of Contents AB-Access Product Overview........................................................................................1-1 1.1 AB-Access System.......................................................................................................1-1 1.2 AB-Access Network.....................................................................................................1-1 1.3 System Components .....................................................................................................1-1 1.3.1 AB-Access System Architecture..........................................................................1-2 1.3.2 Base Station Function...........................................................................................1-3 1.3.3 Subscriber Unit Function......................................................................................1-3 1.3.4 EMS Function.......................................................................................................1-4 1.3.5 System Configuration Selection...........................................................................1-4 Getting Started ...............................................................................................................2-1 2.1 Skills Required .............................................................................................................2-1 2.2 Information Needed From Your Service Provider.......................................................2-1 2.3 Required Tools and Equipment....................................................................................2-2 2.4 Unpacking the Equipment............................................................................................2-2 2.5 Performing A Site Survey ............................................................................................2-4 2.5.1 What You Need...................................................................................................2-4 2.5.2 Access Point Locations ........................................................................................2-4 2.5.3 Selecting An Access Point ...................................................................................2-6 2.5.4 AB-Access Extender Locations ...........................................................................2-7 Base Station Installation ................................................................................................3-1 3.1 System Overview..........................................................................................................3-1 3.2 Access Points................................................................................................................3-2 3.3 AB-Access Extender Units...........................................................................................3-2 3.4 Anchor Switch..............................................................................................................3-2 3.5 Control Server ..............................................................................................................3-3 3.6 Access Panel.................................................................................................................3-4 3.7 A Note On Cabling.......................................................................................................3-5 3.8 Software Consideration ................................................................................................3-5 Server and Switch Installation ......................................................................................4-1 4.1 Before You Start...........................................................................................................4-1 4.1.1 Information Required ...........................................................................................4-1 4.1.2 Extra Equipment Required...................................................................................4-1 4.1.3 Optional Equipment .............................................................................................4-1 4.2 Unpacking The Equipment...........................................................................................4-1 4.2.1 Anchor Switch......................................................................................................4-2 4.2.2 Control Server ......................................................................................................4-2 4.3 Installing The Equipment .............................................................................................4-2 4.3.1 Position The Equipment .......................................................................................4-2 4.3.2 Making Up Connecting Cables ............................................................................4-2 4.3.3 Connecting The Equipment..................................................................................4-3 4.4 Base Station Access Panel Installation.........................................................................4-4 4.4.1 Access Panel Installation Steps ............................................................................4-5 Adaptive Broadband U-NII Product Installation Manual 05/29/2001 viii Company Proprietary 4.4.2 Powering On The Equipment...............................................................................4-6 Access Point Installation................................................................................................5-1 5.1 Before You Start...........................................................................................................5-1 5.2 Information Required ...................................................................................................5-1 5.2.1 Equipment Required.............................................................................................5-2 5.3 Access Points................................................................................................................5-2 Indoor Patch Panel .......................................................................................................5-3 5.4 5.5 Installing The Equipment .............................................................................................5-3 5.5.1 Overview ..............................................................................................................5-4 5.5.2 Installing The Mounting Poles .............................................................................5-4 5.5.3 Installing On An Antenna Mast ...........................................................................5-4 5.5.4 Installing On Brick Or Masonry...........................................................................5-5 5.5.5 Installing On A Wall With Wood Siding .............................................................5-5 5.6 Mounting The Outdoor Access Points .........................................................................5-6 5.6.1 Installing the Access Panel...................................................................................5-7 5.6.2 Installing The Interconnect Cables.......................................................................5-7 5.6.3 Grounding The System.......................................................................................5-12 AB-Access Extender Installation ..................................................................................6-1 6.1 Before You Start...........................................................................................................6-1 6.2 Information Required ...................................................................................................6-1 6.2.1 Equipment Required.............................................................................................6-1 6.3 AB-Access Extender ....................................................................................................6-2 Indoor Patch Panel .......................................................................................................6-3 6.4 6.5 Installing The Equipment .............................................................................................6-3 6.5.1 Overview ..............................................................................................................6-3 6.5.2 Installing The Mounting Poles .............................................................................6-3 6.5.3 Installing On An Antenna Mast ...........................................................................6-4 6.5.4 Installing On Brick Or Masonry...........................................................................6-4 6.5.5 Installing On A Wall With Wood Siding .............................................................6-5 6.6 Mounting The Outdoor AB-Access Extender..............................................................6-5 6.6.1 Installing the Access Panel...................................................................................6-7 6.6.2 Installing The Interconnect Cables.......................................................................6-7 6.6.3 Grounding The System.......................................................................................6-12 Subscriber Unit Installation ............................................... Error! Bookmark not defined. 7.1 Installation Overview .................................................... Error! Bookmark not defined. 7.2 Installing Mounting Pole .............................................. Error! Bookmark not defined. 7.2.1 Installing on a Brick or Masonry Wall.................. Error! Bookmark not defined. 7.2.2 Installing on a Wall with Wood Siding................. Error! Bookmark not defined. 7.2.3 Installing on an Antenna Mast .............................. Error! Bookmark not defined. 7.3 Installing the Outdoor Subscriber Unit ......................... Error! Bookmark not defined. 7.4 Preparing The Indoor Junction Box .............................. Error! Bookmark not defined. 7.5 Installing the Interconnect Cable .................................. Error! Bookmark not defined. 7.5.1 Routing the Interconnect Cable............................. Error! Bookmark not defined. 7.5.2 Preparing the Interconnect Cable .......................... Error! Bookmark not defined. 7.5.3 Connecting to the Outdoor Subscriber Unit TransceiverError! Bookmark not defined. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 ix Company Proprietary 7.5.4 Connecting to the Indoor Junction Box................. Error! Bookmark not defined. 7.6 Grounding The System.................................................. Error! Bookmark not defined. 7.6.1 Installing A Grounding Rod .................................. Error! Bookmark not defined. 7.6.2 Grounding the Outdoor Subscriber Unit ............... Error! Bookmark not defined. 7.6.3 Grounding the Indoor Junction Box...................... Error! Bookmark not defined. 7.6.4 Assembling and Mounting the Junction Box ........ Error! Bookmark not defined. Indoor Junction Box............................................................ Error! Bookmark not defined. 8.1 ATM Cross-Over Cable ................................................ Error! Bookmark not defined. 8.2 FVC DB-9 To RJ-45 Converter .................................... Error! Bookmark not defined. Testing the System............................................................... Error! Bookmark not defined. 9.1 Introduction ................................................................... Error! Bookmark not defined. 9.2 Equipment Required...................................................... Error! Bookmark not defined. 9.3 Testing........................................................................... Error! Bookmark not defined. 9.3.1 Connecting Test PC............................................... Error! Bookmark not defined. 9.4 Configure The IP Address............................................. Error! Bookmark not defined. 9.5 Using the RSSI Interface for RF Alignment ................. Error! Bookmark not defined. 9.6 Display The Security Page ............................................ Error! Bookmark not defined. 9.7 Optimize The Antenna Alignment ................................ Error! Bookmark not defined. 10 Specifications ................................................................... Error! Bookmark not defined. 10.1 Subscriber Unit Antenna ............................................... Error! Bookmark not defined. 10.2 Access Point Antenna ................................................... Error! Bookmark not defined. 10.3 AB-Access Extender Antenna....................................... Error! Bookmark not defined. Figure 10-3 Typical EX Antenna Pattern.................................. Error! Bookmark not defined. TBD: Update all section and figure numbers from here on forwardError! Bookmark not defined. 10.4 Modem Specifications...................................................... Error! Bookmark not defined. 10.5 Environmental Specifications........................................... Error! Bookmark not defined. 10.5.1 Temperature/Humidity Operation .............................. Error! Bookmark not defined. 10.5.2 Grounding................................................................... Error! Bookmark not defined. 10.5.3 Electrical Specifications ............................................. Error! Bookmark not defined. 10.5.4 Power Consumption ................................................... Error! Bookmark not defined. 10.5.5 Distance Limitations................................................... Error! Bookmark not defined. 10.5.6 Physical Specifications............................................... Error! Bookmark not defined. 10.6 Cable Specifications .......................................................... Error! Bookmark not defined. 10.6.1 Outdoor Cable Specifications..................................... Error! Bookmark not defined. 10.7 RJ-45 Plug Specifications.................................................. Error! Bookmark not defined. 11 Glossary & Acronyms ..................................................... Error! Bookmark not defined. 11.1 Acronyms/Abbreviations............................................... Error! Bookmark not defined. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 Company Proprietary AB-ACCESS SYSTEM LIST OF FIGURES Figure 1-1 AB-Access Typical Deployment................................................................................1-2 Figure 1-2 AB-Access Typical Network Architecture................................................................1-3 Figure 2-1 Outdoor Subscriber Unit Components .......................................................................2-3 Figure 2-2 Access Point Locations.............................................................................................2-5 Figure 2-3 Aligning the Compass and Map ...............................................................................2-6 Figure 2-4 Selecting an Access Point.........................................................................................2-7 Figure 3-1 Base Station Overview ...............................................................................................3-1 Figure 3-2 Outdoor Access Point and Mounting Pole ................................................................3-2 Figure 3-3 Anchor Switch Front Panel .......................................................................................3-2 Figure 3-4 Dell 2450 Control Server Rear Panel........................................................................3-3 Figure 3-5 Access Panel..............................................................................................................3-4 Figure 4-1 ATM Cross-Over Cable.............................................................................................4-3 Figure 5-1 Diagram of Six Access Points for 360 degree Coverage...........................................5-1 Figure 5-2 Outdoor Access Point Components...........................................................................5-3 Figure 5-3 Access Panel used as Patch Panel .............................................................................5-3 Figure 5-4 Mounting Pole Installed on Pole or Antenna Mast ...................................................5-4 Figure 5-5 Mounting Pole Installation ........................................................................................5-5 Figure 5-6 Mounting Pole on Clapboard Siding .........................................................................5-5 Figure 5-7 Mounting Parts for an Outdoor Access Point............................................................5-6 Figure 5-8 Access Point Rear View ............................................................................................5-6 Figure 5-9 Tilt Bracket................................................................................................................5-7 Figure 5-10 Access Point with Mounted Tilt Bracket ................................................................5-7 Figure 5-11 Grommet Location - Underside of Access Point.....................................................5-8 Figure 5-12 Outdoor Transceiver End of the Interconnect Cable with Cable Preparation .........5-9 Figure 5-13 Outdoor Transceiver End of the Interconnect Cable with Shielding.......................5-9 Figure 5-14 Interconnect Cable Installation to Outdoor Access Point - Bottom View.............5-11 Figure 5-15 Access Panel showing Connections to Access Point............................................5-11 Figure 5-16 Ground Connections to Access Point Transceiver ................................................5-12 Figure 5-17 Mounting Pole with Ground Lug...........................................................................5-13 Figure 6-1 Outdoor AB-Access Extender Components..............................................................6-3 Figure 6-2 Access Panel used as Patch Panel .............................................................................6-3 Figure 6-3 Mounting Pole Installed on Pole or Antenna Mast ...................................................6-4 Figure 6-4 Mounting Pole Installation ........................................................................................6-5 Figure 6-5 Mounting Pole on Clapboard Siding .........................................................................6-5 Figure 6-6 Mounting Parts for an Outdoor AB-Access Extender...............................................6-6 Figure 6-7 AB-Access Extender Rear View ...............................................................................6-6 Figure 6-8 Tilt Bracket................................................................................................................6-6 Figure 6-9 AB-Access Extender with Mounted Tilt Bracket......................................................6-6 Figure 6-10 Grommet Location - Underside of AB-Access Extender........................................6-7 Figure 6-11 Outdoor Transceiver End of the Interconnect Cable with Cable Preparation .........6-9 Figure 6-12 Outdoor Transceiver End of the Interconnect Cable with Shielding.......................6-9 Adaptive Broadband U-NII Product Installation Manual 05/29/2001 xi Company Proprietary Figure 6-13 Interconnect Cable Installation to Outdoor AB-Access Extender - Bottom View 6-11 Figure 6-14 Access Panel showing Connections to AP/EX.....................................................6-11 Figure 6-15 Ground Connections to AB-Access Extender Transceiver ...................................6-12 Figure 6-16 Mounting Pole with Ground Lug...........................................................................6-13 Figure 7-1 AB-Access Subscriber Unit Installation Overview .... Error! Bookmark not defined. Figure 7-2 Mounting Pole Drill Locations .................................. Error! Bookmark not defined. Figure 7-3 Mounting Pole Installation Using Expansion Sleeves and Lag BoltsError! Bookmark not defined. Figure 7-4 Mounting Pole on Clapboard Siding ......................... Error! Bookmark not defined. Figure 7-5 Mounting Pole Installed on Pole or Antenna Mast .... Error! Bookmark not defined. Figure 7-6 Outdoor Subscriber Unit Mounted on Wall................ Error! Bookmark not defined. Figure 7-7 Junction Box Wall Mount (Face Plate and PCB Removed)Error! Bookmark not defined. Figure 7-8 Interconnect Cable Routing Solutions........................ Error! Bookmark not defined. Figure 7-9 Grommet Location -- Underside of Subscriber Unit .. Error! Bookmark not defined. Figure 7-10 Outdoor Subscriber Unit of the Interconnect Cable with Cable PreparationError! Bookmark not defined. Figure 7-11 Outdoor Subscriber Unit End of the Interconnect Cable with ShieldingError! Bookmark not defined. Figure 7-12 Interconnect Cable Installation to Subscriber Unit -- Bottom ViewError! Bookmark not defined. Figure 7-13 Interconnect Cable Connections to Indoor Junction BoxError! Bookmark not defined. Figure 7-14 Ground Connections for Subscriber Unit ................. Error! Bookmark not defined. Figure 7-15 Mounting Pole with Ground Lug.............................. Error! Bookmark not defined. Figure 7-16 Indoor Junction Box Ground Connection................. Error! Bookmark not defined. Figure 8-1 Indoor Junction Box (Wall Plate Enclosure).............. Error! Bookmark not defined. Figure 8-2 Indoor Junction Box Inside........................................ Error! Bookmark not defined. Figure 8-3 ATM Cross-Over Cable.............................................. Error! Bookmark not defined. Figure 8-4 DB-9 To RJ-45 Converter .......................................... Error! Bookmark not defined. Figure 9-1 Security Screen........................................................... Error! Bookmark not defined. Figure 9-2 RSSI Sample Web Page ............................................. Error! Bookmark not defined. Figure 10-1 Typical SU Antenna Pattern..................................... Error! Bookmark not defined. Figure 10-2 Typical AP Antenna Pattern...................................... Error! Bookmark not defined. Figure 10-3 Typical EX Antenna Pattern...................................... Error! Bookmark not defined. Figure 10-4 Powering SU through Junction Box ......................... Error! Bookmark not defined. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 xii Company Proprietary AB-ACCESS SYSTEM LIST OF TABLES LIST OF TABLES Table 1-1 Supported AB-Access SU Configurations..................................................................1-5 Table 1-2 Supported AB-Access AP Configurations..................................................................1-5 Table 2-1 Required Tools and Extra Equipment..........................................................................2-2 Table 2-2 Packing List ...............................................................................................................2-3 Table 4-1 Required Tools and Equipment ..................................................................................4-1 Table 4-2 Required Cables ..........................................................................................................4-3 Table 4-3 Base Station Access Panel Description.......................................................................4-4 Table 5-1 Required Tools and Equipment ..................................................................................5-2 Table 5-2 AP Components ..........................................................................................................5-2 Table 5-3 Cable Legend for Interconnect Cable .......................................................................5-10 Table 6-1 Required Tools and Equipment ..................................................................................6-1 Table 6-2 EX Components ..........................................................................................................6-2 Table 6-3 Cable Legend for Interconnect Cable .......................................................................6-10 Table 7-1 Required Tools And Equipment .................................. Error! Bookmark not defined. Table 7-2 Required Tools and Equipment ................................... Error! Bookmark not defined. Table 7-3 Required Tools and Equipment .................................. Error! Bookmark not defined. Table 7-4 Required Tools and Equipment ................................... Error! Bookmark not defined. Table 7-5 Required Tools and Equipment ................................... Error! Bookmark not defined. Table 7-6 Required Tools and Equipment ................................... Error! Bookmark not defined. Table 7-7 Cable Legend for Interconnect Cable ........................... Error! Bookmark not defined. Table 7-8 Required Tools and Equipment ................................... Error! Bookmark not defined. Table 8-1 Cable Legend - Junction Box Interconnect Cable ....... Error! Bookmark not defined. Table 9-1 RSSI Link Validity ...................................................... Error! Bookmark not defined. Table 10-1 Subscriber Unit Antenna Specifications .................... Error! Bookmark not defined. Table 10-2 Access Point Antenna Specifications......................... Error! Bookmark not defined. Table 10-3 AB-Access Extender Antenna Specifications............ Error! Bookmark not defined. Table 10-4 Modem Specifications................................................ Error! Bookmark not defined. Table 10-5 Environmental Specifications .................................... Error! Bookmark not defined. Table 10-6 SU, EX and AP Power Consumption......................... Error! Bookmark not defined. Table 10-7 SU Weight and Size ................................................... Error! Bookmark not defined. Table 10-8 Outdoor Cable Specifications .................................... Error! Bookmark not defined. Table 10-9 RJ-45 Plug Specifications .......................................... Error! Bookmark not defined. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 xiii Company Proprietary SECTION 1 AB-Access Product Overview AB-Access Product Overview 1.1 AB-Access System The Adaptive Broadband AB-Access System is a broadband, fixed, wireless access network for Internet, data, video, and voice applications. AB-Access can enhance or replace existing networks, wired or wireless, or be used to develop new networks. The AB-Access System offers: • Point-to-Multipoint (PMP) Wireless Access Network • Point-to-Point (PTP) Wireless Access Network [AB-Access Extender] • End-to-End Connectivity • Spectrum Efficiency per Offered Load • Powerful, Flexible Elements. 1.2 AB-Access Network The AB-Access network consists of wireless 25 Mbps cells similar in topology to the cellular networks of today. AB-Access networks are designed for rapid and easy deployment, and constructed from a number of Base Stations deployed in a conventional cellular pattern. Deployment can vary from a number of small island sites to complete coverage of a chosen geographical area. AB-Access Extender allows these cell sites to be linked together with highspeed, long range, point-to-point connections. 1.3 System Components The AB-Access System is comprised of the following five major components: • Subscriber Unit (SU) – Located at customer premises and provides either ATM or standard IP over Ethernet connectivity. • Access Point (AP) - The Access Point is the cornerstone component of the Base Station. The AP is the interface between the Service Provider’s terrestrial network and the wireless fabric. Each AP has the capability to provide network service at the Physical, Data Link, and Network Layers of the OSI reference model. AB-Access Extender (EX) - The AB-Access Extender is the inter-Base Station linking component. The EX is the interface between the Service Provider’s terrestrial network and the wireless PMP fabric. Each EX has the capability to provide network service at • Adaptive Broadband U-NII Product Installation Manual 05/29/2001 1-1 Company Proprietary the Physical, Data Link, and Network Layers of the OSI reference model. Each EX can provide ATM or Ethernet backhaul. • Anchor Switch (AS) - An ATM (or Ethernet) Anchor Switch in each Base Station is used to multiplex the traffic from all APs onto a Backhaul port. • Control Server (CS) - The Control Server is a reliable server running the Linux OS. It provides a number of functions including: configuration, authentication, set-up of management PVCs, and support of the Element Management System (EMS). • Element Management System (EMS) – A GUI based application suite that allows administrators to configure, control, and monitor all components of the system. 1.3.1 AB-Access System Architecture Figures 1-1 and 1-2 show an AB-Access System’s typical deployment and network architecture. Figure 1-1 AB-Access Typical Deployment Typically 6 Access Points per Base Station SU Base Station Up to 16 (254) Subscriber Units per Access Point SU AP AP AP Element Management Server 4400 WIN NT 4.0 Ethernet ATM25 DS3 / OC3 ATM Switch SU - Subscriber Un AP - Access Point CS - Control Serve BS - Base Station ATM ATM25 Ethernet Manual 05/29/2001 Adaptive Broadband U-NII Product Installation ControlServer Router ISP Router 2450Linux Li 1-2 Company Proprietary Figure 1-2 AB-Access Typical Network Architecture TBD: Add AB-Access Extender to this diagram 1.3.2 Base Station Function The Base Station enables wireless communications between the Subscriber Units and the Wide Area Network (WAN). Base Station elements include: • Access Point • AB-Access Extender • Access Panel (same function as Junction Box) • Anchor Switch • Control Server • Termination Point and Lightning Arrestor • 48 VDC Power Supply • Uninterruptible Power Supply (UPS) (optional). 1.3.3 Subscriber Unit Function The Subscriber Unit is an integrated device that mounts externally at the customer site. This device provides either ATM or standard IP over Ethernet, via 25 Mbps ATM, wireless communications with the Base Station. Subscriber Unit elements include: • Antenna • Radio/Transceiver • Modem • MAC (Media Access Controller) • Network Interface • Internal Junction Box Adaptive Broadband U-NII Product Installation Manual 05/29/2001 1-3 Company Proprietary • Cabling. 1.3.4 EMS Function The central Element Management System (EMS), which system administrators access via a GUI-based application suite (the AB-NetAccess client software), is run on a Pentium class computer under Windows NT. The EMS allows the user to configure, control, and monitor all components of the AB-Access System. EMS software elements include: • SQL Database • Java GUI Interface • CORBA Object Infrastructure. 1.3.5 System Configuration Selection Before installing a new unit or upgrading a unit, the network manager must know what configuration option to use. This is important for both static and dynamic installations. The upgrade process will place a unit in a certain state. The state of this unit will be very important depending upon whether the unit is already being used in production or about to be put into use. Units in production will need to be upgraded and placed back into production using the configuration currently in place. New units will require the proper configuration in order to come online fast and efficiently. This whole process relies on the fact that the units are programmed properly. Units operating in static mode will want to retain this mode. Selecting the wrong configuration may result in a static unit being placed in a dynamic registration mode, making it potentially unmanageable remotely. Similarly, upgrading a unit running in a routed topology to a bridge topology will have a significant impact on functionality. Contained in each system software release is a file that lists the possible configuration options. The file is called “configurations” and looks similar to Tables 1-1 and 1-2. This file is split into two tables, one for the AP and one for the SU configurations. These tables are used to determine which configuration the unit will be programmed in after upgrade. For the purposes of network and software configuration, the AB-Access Extender units appear as static point-to-point SU units. They support Ethernet or ATM wired interfaces. CLIP, RFC1483 and native ATM are supported static configuration for these units. An AB-Access Extender point-to-point link consists of two Extender units, a Head End Unit (“AP”) and an Upstream Subscriber Unit (“SU”). Adaptive Broadband U-NII Product Installation Manual 05/29/2001 1-4 Company Proprietary Table 1-1 Supported AB-Access SU Configurations ============================================ Configuration Protocol AP role System Mode Interface -----------------------------------------------------------------------------------------1 CLIP terminated static Ethernet CLIP terminated interactive Ethernet RFC1483 terminated interactive Ethernet RFC1483 switched interactive Ethernet PPP switched interactive Ethernet CLIP terminated installation Ethernet RFC1483 terminated installation Ethernet RFC1483 switched installation Ethernet PPP switched installation Ethernet Table 1-2 Supported AB-Access AP Configurations ============================================ Configuration Protocol AP Role System Mode Interface -----------------------------------------------------------------------------------------1 CLIP terminated static ATM CLIP terminated interactive ATM RFC1483 terminated interactive Ethernet RFC1483 switched interactive ATM PPP switched interactive ATM CLIP terminated static Ethernet The first column in the Tables above refers to a configuration number. This number will be used as a parameter to the upgrade process. The second column identifies the protocol or network topology. Routed topologies will use the CLIP protocol, bridged will use the RFC1483 protocol, Adaptive Broadband U-NII Product Installation Manual 05/29/2001 1-5 Company Proprietary and PPP topologies will use the PPP protocol. The column titled “AP Role” is used to specify whether the AP will terminate PVCs from the SU or switch them through to another termination point. This is only pertinent to the AP upgrade. The fourth column, “System Mode”, refers to how the unit will act in the network. A unit in static mode will not try to register with the Element Management System but will instead use the configuration files found in the Flash file system. A unit in interactive mode will automatically try to register with EMS (dynamically) via the AP with the strongest RF signal it can detect. Installation mode, used for SUs only, places the SU is a mode which will ultimately allow it to register dynamically, but upon first boot, the unit requires manual intervention to complete its RF alignment. The last column, “Interface” defines the type of terrestrial interface the unit will use after reboot. This is important to note since improper configuration selection will change the terrestrial interface type. This may make the unit appear unreachable after reboot. With every release, be sure to carefully look over the configuration option file, as new options are occasionally added. To reset a unit to factory defaults, an AP should be upgraded to configuration #4 and an SU to configuration #1(reference Tables 1-1 and 1-2). For more information about configuring your AB-Access System, reference the U-NII Configuration and User’s Guide. Following are instructions for setting up Subscriber Units, Base Stations, AB-Access Extender and Access Points. A Glossary of definitions and acronyms is at the end of this manual. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 1-6 Company Proprietary SECTION 2 Getting Started 2 Getting Started 2.1 Skills Required The AB-Access U-NII Product Installation procedures require some construction-related experience using both power and hand tools. Answer the following questions to determine whether you have the skills attempt the installation. • • • • • Are you comfortable working at heights? (The installation may require you to climb a ladder and work at heights depending on where you need to install your outdoor transceiver. Keep in mind, you will also carry tools and equipment with you to the installation site.) Have you ever installed an RJ-45 connector to an Ethernet cable? (This is required if you are not using a standard length cable interconnect cable kit between the outdoor transceiver and the indoor junction box.) Have you run telephone cable, wired a telephone jack, or connected telephone wire connections to a punch down block? Have you ever installed expansion shields into brick or masonry walls? (This requires drilling holes in masonry using masonry drill bits.) Have you ever wired an electrical outlet? Although you won’t wire an outlet, you will be required to run ground wires and clamp them to an earth grounding rod or a cold water pipe. If you can perform all the above tasks, then you should be able to install the AB-Access System. If you are unsure of your ability to perform these tasks, contact a more qualified installer, via your local AB-Access System provider. 2.2 Information Needed From Your Service Provider Your service provider should have supplied you with the following information. Please contact your service provider before commencing installation, if you do not have all of this information: • Locations of any local Access Points, which you should be able to connect to. • The IP address of your Subscriber Unit. • IP address and subnet mask, which you need to configure a Test PC. This is so you can check to see if your SU is working, align your outdoor transceiver correctly, and confirm that you can connect to your service provider. • Any required static configuration for AB-Access Extender units e.g. IP addresses, channels to be used etc. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 2-1 Company Proprietary 2.3 Required Tools and Equipment This section lists all the extra tools and equipment mentioned in this guide that you will need to perform the installation. None of the items listed in Table 2-1 are supplied with the kit, so make sure you gather everything you need before you start. Use the table below to check exactly what you will need (this will depend on where you are going to install the outdoor transceiver). Table 2-1 Required Tools and Extra Equipment TBD: add tool requirement for AB-Access Extender Tools Required Extra Equipment Required Compass ¼ inch grounding rod Area map with an accurate direction Grounding clamp legend showing magnetic north Phillips-head screwdriver Grounding wire Flat-head screwdriver Roll of UTP CAT 5 cable Hammer or mallet #6 wood screws Power drill Cable clip 1/8 inch drill bit Anchor sleeves ¼ inch masonry drill bit RJ-45 connectors (plastic bodied) 3/16 inch hex (Allen) wrench 1 inch copper tape Bubble level or plumb line Ethernet Hub (10BaseT) Adjustable wrench Wire snake (if routing cable through Recommend a 19” rack to hold the interior walls) monitor, Element Management System, Anchor Switch, and Control Server. Crimping tool (must be specifically matched for the RJ-45 connector used) Wire stripper Small wire cutters Punch down tool 2.4 Unpacking the Equipment Table 2-2 lists all the standard parts that are supplied in your AB-Access Subscriber Unit Installation Package. Please take the time to unpack the package and check its contents against this list. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 2-2 Company Proprietary Figure 2-1 Outdoor Subscriber Unit Components Table 2-2 Packing List Item Quantity Notes Outdoor Subscriber Unit See item 1 in Figure 2-1 Mounting pole See item 2 in Figure 2-1 Pole clamp See item 3 in Figure 2-1 M6 washer See item 4 in Figure 2-1 M3 x M10 machine thread screws See item 5 in Figure 2-1 CAT-5 interconnect cable Power supply Power cord Indoor junction box Adaptive Broadband U-NII Product Installation Manual 05/29/2001 2-3 Company Proprietary 2.5 Performing A Site Survey This section explains how to select the best location for mounting the outdoor transceiver. The steps you will perform are: 1. Determine which Access Points you can communicate with. 2. Determine the direction of available Access Points from the house or building. 3. Select an Access Point with an unobstructed Line of Sight (LOS). Attention! It is very important that you choose a CLEAR LINE OF SIGHT for the placement of your Access Point Units and Subscriber Units. 2.5.1 What You Need • Compass (or protractor). • Area map with an accurate direction legend showing magnetic north. • Access Point locations – these should be provided by your service provider. 2.5.2 Access Point Locations If you are installing the unit without the aid of a qualified installer, you need to determine the general direction of any Access Points from your house or building. You may be able to ‘see’ several APs, depending on your coverage area. Attention! The following method uses a compass to find the bearing of any APs from your site. An alternative method is to use a protractor to measure the angle between North and a line to the AP from your site. This tells you the compass bearing to use when aligning your outdoor transceiver. 1. On your map, mark the location of your house or building 2. Mark the locations of any Access Points – these should have been supplied by your service provider: Adaptive Broadband U-NII Product Installation Manual 05/29/2001 2-4 Company Proprietary Figure 2-2 Access Point Locations 3. Place the compass on the map on or near the magnetic north indicator. 4. Turn the compass so that the magnetic north indicator needle aligns with the N or North indicator on the compass body. 5. Rotate the map, keeping the compass stationary, so the map’s North Indicator aligns with the North Indicator of the compass (see Figure 2-3). Move the compass over your location on the map and read off the bearing to the AP. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 2-5 Company Proprietary Figure 2-3 Aligning the Compass and Map 6. Write down the directions (compass bearings) of your Access Points. For example, in Figure 2-3, Access Point A is located northwest of the building and Access Point B is located between north and northeast. (If you can be more accurate than this, you will get better reception when you install your outdoor transceiver.) 2.5.3 Selecting An Access Point In order for your AB-Access System to work correctly, you MUST establish a clear line of sight to one or more of the Access Points recommended by your AB-Access System provider. 1. Using the compass bearings you wrote down in the previous section, walk around your building to find a suitable line of sight path to mount your outdoor transceiver – see Figure 2-4. Attention! A clear line of sight means a path unobstructed by trees, dense foliage, or other buildings. If necessary, move to an upstairs window or rooftop location to better view the surrounding area for possible blockages in the path. Also, be sure to consider seasonal changes. A location that is unobstructed in the winter may be obstructed by foliage in the spring, summer, and autumn. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 2-6 Company Proprietary Figure 2-4 Selecting an Access Point You should mount your outdoor Subscriber Unit as high as possible on your building, and align it to the compass reading you have just taken. For example, the previous Figure 2-4 shows the path to Access Point A obstructed by a cluster of trees. However, there are two possible mounting locations for the outdoor Subscriber Unit giving a clear line of sight to Access Point B. Attention! Your outdoor transceiver has a beam width of approximately 20 degrees. You will need to be fairly accurate when aligning your transceiver to the compass bearing you wrote down earlier (the more accurate your compass readings, the better). 2. If you do come up with two or more suitable locations for the outdoor Subscriber Unit, choose the one that is easiest for you to reach, when it comes to installing! 2.5.4 AB-Access Extender Locations In order for your AB-Access Extender link to work correctly, you MUST establish a clear line of sight between the Extender AP and Extender SU. Attention! A clear line of sight means a path unobstructed by trees, dense foliage, or other buildings. Attention! Your outdoor transceiver has a beam width of approximately 10 degrees. You will need to be fairly accurate when aligning your transceiver to the compass bearing you wrote down earlier (the more accurate your compass readings, the better). TBD: Additional instructions for AB-Access Extender Adaptive Broadband U-NII Product Installation Manual 05/29/2001 2-7 Company Proprietary SECTION 3 Base Station Installation 3 Base Station Installation 3.1 System Overview This section briefly describes the AB-Access hardware and software system components that comprise a Base Station. Figure 3-1 Base Station Overview Adaptive Broadband U-NII Product Installation Manual 05/29/2001 3-1 Company Proprietary 3.2 Access Points Figure 3-2 Outdoor Access Point and Mounting Pole A Base Station can have up to six Access Points. Each AP consists of an outdoor transceiver – the antenna and associated electronics that transmit and receive broadband wireless signals to and from Subscriber Units. 3.3 AB-Access Extender Units A Base Station may have a number of AB-Access Extender units. Each EX consists of an outdoor transceiver – the antenna and associated electronics that transmit and receive broadband wireless signals to and from the EX at the other end of the backhaul link. 3.4 Anchor Switch Port 101 – first one on the left connects the switch to an ATM25 card on the Control Server Figure 3-3 Anchor Switch Front Panel This is typically an Access NGI WAN Access Switch, model VSW 200E, from FVC.COM. The Anchor Switch has the following connections: • Typically, six or 12 ATM25 ports: Adaptive Broadband U-NII Product Installation Manual 05/29/2001 3-2 Company Proprietary Port 101 – connects the switch to an ATM25 card on the Control Server using an ATM cross-over cable. - The other ATM25 ports connect to each AP via the indoor junction box or access panel, using ATM cross-over cable. • Switch configuration ports: - Console Port – Connects to the COM2 port on the Control Server. This is the usual method for monitoring and configuring the switch. Standard serial port settings are 8,n,1 no flow control. - Ethernet Port – Optionally, this can also be used to access the switch remotely. You will need to give the switch an IP address, and then configure it via a machine with an Ethernet card. Please see the V-Switch User’s Guide (supplied with the switch) for detailed information on configuring the switch. • 3.5 (Optional) Backhaul connection – This can be via: - OC3 - DS3 - Multiple T1s. - AB-Access Extender Control Server ATM25 port Embedded Ethernet NIC Interface Figure 3-4 Dell 2450 Control Server Rear Panel Shown in Figure 3-4 is the rear of a Dell PowerEdge 2450 Control Server. It comes pre-installed with the necessary hardware to get a Base Station up and running. It provides an interface Adaptive Broadband U-NII Product Installation Manual 05/29/2001 3-3 Company Proprietary between the anchor switch and the network management software. The ports on the rear panel are as follows: • ATM25 port – Connects to port 101 on the anchor switch. • COM2 port – Connects to the Console port on the anchor switch. Used for monitoring and configuring the switch. Attention! This is a DB-9 connector. First, plug the DB-9 to RJ-45 adapter (supplied with FVC switch) into this port, then plug a straight through patch cable from the switch into the adapter. It is important to note that the user must use the FVC supplied serial adapter, as other adapters may not operate correctly! Please see the V-Switch User’s Guide (supplied with the switch) for detailed information on configuring the switch. • Mouse port • Keyboard port • Monitor port • Power connector – There may be one or three of these, depending on your model Control Server. 3.6 Access Panel Figure 3-5 Access Panel The Access Panel provides an interface between the Anchor Switch (AS), a 48V power supply, and the APs. It includes: • • • • • Rack-mounted unit that can handle up to six APs Connects to a redundant 48V DC power supply RJ-45 connectors to take interconnect cables from APs RJ-45 connectors to take ATM cross-over cables to the AS Grounding points Adaptive Broadband U-NII Product Installation Manual 05/29/2001 3-4 Company Proprietary • • 3.7 LEDs to indicate AP status Separate on/off switches for each AP / AB-Access Extender. A Note On Cabling Attention! Most of the cabling used in the AB-Access System is CAT5. You will need to be aware of the following limits on CAT5 cable lengths: • • The interconnect cable from the indoor junction box to an outdoor transceiver must be less than 60 meters. This is due to DC resistance loss over the distance of the cable run. The combined length of ATM cross-over cable (from the junction box to the anchor switch) and the interconnect cable must be less than 100 meters. 3.8 Software Consideration As an installer, you need to know how to use a serial console to: • Configure the Permanent Virtual Circuits (PVCs) on the AS. • Check the status of communications between the AS and CS. • Check the backhaul connection. You will use a Command Line Interface (CLI) to perform any necessary configuration. For additional information, please see the U-NII Configuration and User’s Guide. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 3-5 Company Proprietary SECTION 4 Server and Switch Installation 4 Server and Switch Installation 4.1 Before You Start This part of the manual is aimed at experienced network installers. It explains how to install and configure a Control Server(CS) and Anchor Switch (AS), and how to get an AB-Access Base Station up-and-running. It does not tell you how to manage an AB-Access network. This section lists the information you will need to know before you can install a Base Station. 4.1.1 Information Required Before you perform the installation, you will need to know which outdoor transceivers are connected to which port on the indoor junction box (the Access Point (AP) installer should have made a note of this). 4.1.2 Extra Equipment Required Before you perform the installation, you will need the following equipment shown in Table 4-1: Table 4-1 Required Tools and Equipment Tools Required Extra Equipment Required Crimping tool (must be specifically matched RJ-45 connectors for the RJ-45 connector used) Wire stripper Roll of CAT-5 cable Small wire cutters Monitor and cables 4.1.3 Optional Equipment In case of power outages, an Uninterruptible Power Supply (UPS) is optional equipment that is available and highly recommended for purchase, but it is not covered in this guide. 4.2 Unpacking The Equipment Carefully unpack the equipment and check the items against the following lists. You should have the following items (you may also have purchased a monitor, but as this is optional and it is not included below). Adaptive Broadband U-NII Product Installation Manual 05/29/2001 4-1 Company Proprietary 4.2.1 Anchor Switch The Anchor Switch is an Access NGI WAN Access Switch, model VSW 200E, from FVC>COM. The box should contain: • Anchor Switch • V-Switch User’s Guide • Power cord • Serial port adapter. 4.2.2 Control Server The Control Server is a Dell PowerEdge 2450. The box should contain: • Control Server. • Mouse. • Keyboard • Software installation CD-ROMs (note that all necessary software has been preinstalled) • Two power cords • Keys for accessing drive bays and internal upgrade options (see below for key locations). • Manuals, including the Dell 1 x 8 Backplane Option leaflet. 4.2.2.1 Key Locations The keys supplied with the Control Server are located as follows: • 4300 – Behind the “4300” label on the front panel; press the label to open the hidden compartment. • 4350 – On a hanger on the rear panel • 2450 – On a hanger on the rear panel. 4.3 Installing The Equipment This section explains how to connect up the anchor switch, Control Server and outdoor transceivers. 4.3.1 Position The Equipment After unpacking all the equipment, position the anchor switch and Control Server so as to minimize the distances between them, the indoor junction box, and your power outlets. You may want to rack mount the anchor switch and Control Server. Please see the V-Switch User’s Guide. 4.3.2 Making Up Connecting Cables The following Table 4-2 shows the various types and lengths of cable. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 4-2 Company Proprietary Table 4-2 Required Cables Cable Run AS port 101 to CS ATM port AS Console port to CS COM (via DB-9 to RJ-45 adapter) AS ports 102, 103 etc. to indoor junction box Cable Type CAT5 No. Required Connectors RJ-45 CAT5 RJ-45 ATM Cross-over Same as number of transceivers RJ-45 – see below for pinout 4.3.2.1 ATM Cross-Over Cable The pin connections for making up an ATM cross-over cable are as follows: Pin Pin Figure 4-1 ATM Cross-Over Cable 4.3.3 Connecting The Equipment To connect the equipment, proceed as follows: 1. Connect from port 101 on the anchor switch to the ATM port on the rear panel of the Control Server. Use a standard CAT5 cable with an RJ-45 connector on each end. 2. Connect from port 102 on the anchor switch to the appropriate port on the access panel. Use an ATM cross-over cable with an RJ-45 connector on each end. 3. Repeat step 2, using ports 103, 104, 201, 202, 203 and 204, until you have connected to all the ‘live’ ports on the access panel. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 4-3 Company Proprietary 4. Insert the DB-9 to RJ-45 adapter into the COM2 port on the Control Server. Connect from the Console port on the anchor switch to the DB-9 to RJ-45 adapter on the COM2 port of the Control Server. 5. Connect the mouse and keyboard to the Control Server. 6. Connect your monitor’s signal cable to the monitor port on the Control Server. 7. Connect the power cords for the Control Server, anchor switch, indoor junction box and monitor to AC wall outlets, but do not switch on. 4.4 Base Station Access Panel Installation The following steps cover installing the indoor Access Panel installation. Table 4-3 gives a description of the Access Panel and Figure 4-2 shows a photo of it. As designed, these Access Panels exactly duplicate the circuitry of the existing wall boxes. Installation follows the same directions. However, no punch down of the STP cable is needed on the radio side of the panel. Straight through CAT5 STP cables are used to connect the panel to the radio. The patch panel is designed to replace six wall boxes in a Base Station. The Artesyn power supplies are to be replaced by power supplies such as Kepco’s (part #PS-RM0101-1000953) rack mounted power supply operating at 48 V - 3.6 A DC. Table 4-3 Base Station Access Panel Description Name Base Station Access Panel Description Model # Revision # CLEI code Access Panel Rack Mount 6 AP/EX Interfaces WB-05001 v1.00 NA Figure 4-2 Access Panel Ports Adaptive Broadband U-NII Product Installation Manual 05/29/2001 4-4 Company Proprietary 4.4.1 Access Panel Installation Steps 1. At the Access Panel, be sure all power switches are set to OFF. 2 Determine ports to be used on the Access Panel, and set jumpers on rear of panel to desired setting (either Ethernet or ATM). Reference the following Figure 4-3. Jumpers Jumpe r Configuration Figure 4-3 Access Panel Jumpers 3. Position Access Panel 4. Plug in power supply and turn on. 5. Adjust to +48VDC and turn off. 6. Obtain red, black, and green 18 gauge wire. Measure and cut enough of each color to connect the Access Panel to the power supply. 7. Using wire strippers, strip approximately 1/4" from one end of all three leads. 8. Insert the red lead into the +48V connection and tighten with precision flat tip screwdriver. 8. Insert black lead into the -48V connection and tighten with precision flat tip screwdriver. 9. Insert the green lead into the ground connection and tighten with precision flat tip screwdriver. Reference the following Figure 4-4. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 4-5 Company Proprietary + 48V - 48 V GROUND Figure 4-4 Access Panel Power Connection Wires 11. Using wire strippers, strip approximately 1/2" off the other end of all three leads. 12. Connect the red lead to the +48V on power supply. 13. Connect the black lead to the -48V on power supply. 14. Connect the green lead to ground on power supply. 4.4.2 Powering On The Equipment Power on the equipment as follows: 1. Power on the anchor switch. (It will go through its startup procedure, which can take up to three minutes.) 2. Power on the monitor. 3. Power on the Control Server. 4. When the server has finished its startup procedure, you will see a login prompt. 5. Enter the user login (root) and the system password (letmein) and press Enter. (Note text is all lower-case.) 6. Turn ON the power supply. 7. If any of the six-transceiver power switches are OFF, turn them ON. 8. For each live transceiver, check that the yellow LED on the junction box is ON. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 4-6 Company Proprietary SECTION 5 Access Point Installation 5 Access Point Installation 5.1 Before You Start This section lists the information you need on-hand before you can install a Base Station. 5.2 Information Required Before you perform the installation, a site survey should have been performed by the service provider. From this, you will need to know: • Number of APs to install • Where the outdoor transceivers will be mounted (antenna mast, pole or building) • Heights at which the outdoor transceivers will be mounted. • Transceiver directional information (azimuth and elevation). You will probably be installing six APs on a mast or pole, giving 360 degree coverage in 60 degree sectors, as shown in Figure 5-1. Figure 5-1 Diagram of Six Access Points for 360 degree Coverage IMPORTANT – Be sure to record for future reference the MAC address found on the AP unit BEFORE you install it. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-1 Company Proprietary 5.2.1 Equipment Required Table 5-1 lists the tools and equipment you will need to install Access Points. Table 5-1 Required Tools and Equipment Tools Required Compass and protractor Area map Phillips-head screwdriver Flat-head screwdriver Hammer or mallet Power drill 1/8 inch drill bit ¼ inch masonry drill bit Equipment Required ¼ inch grounding rod Grounding clamp Grounding wire CAT5 cable #6 wood screws Cable clips Anchor sleeves RJ-45 connectors (plastic bodied) 3/16 inch hex (Allen) wrench or 10 mm Bubble level or plumb line Adjustable wrench Wire snake (if routing cable through interior walls) Crimping tool (must be specifically matched for the RJ-45 connector used) Wire stripper Small wire cutters Punch down tool 5.3 Access Points Table 5-2 lists the main components of an Access Point. Table 5-2 AP Components Item Outdoor transceiver Mounting pole Pole clamp M6 washer M3 x M10 machine thread screws Grounding lug Indoor junction box Power supply and cord Quantity Notes See item 1 in Figure 5-2 See item 2 in Figure 5-2 See item 3 in Figure 5-2 See item 4 in Figure 5-2 See item 5 in Figure 5-2 See item 6 in Figure 5-2 6-way rack-mounted unit Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-2 Company Proprietary Figure 5-2 Outdoor Access Point Components 5.4 Indoor Patch Panel Figure 5-3 shows the Base Station Access Panel used as an indoor patch panel. AP OUT AP IN Figure 5-3 Access Panel used as Patch Panel 5.5 Installing The Equipment This section explains how to install an AP transceiver onto a variety of surfaces, connect them to the indoor junction box, and ground the system. The most likely scenario is to install six transceivers on a single tower or mast 60 degrees apart. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-3 Company Proprietary 5.5.1 Overview Following are the installation steps you will perform: 1. Install the mounting poles. 2. Mount the outdoor transceivers. 3. Mount the access panel. 4. Ground the outdoor transceivers and access panel 5. Connect the interconnect cables. 5.5.2 Installing The Mounting Poles First install the mounting poles, on which you will mount the outdoor transceivers. Bear in mind the direction in which the transceivers will point. Attention! The mounting pole must be mounted in a vertical position. Failure to do so may result in improper alignment of the outdoor transceiver. If you need to tilt the transceiver down to avoid self-interference in a cellular-style deployment, you should use an (optional) tilt bracket. Warning! The mounting pole must be grounded. See Grounding The System in Section 5.6.3. 5.5.3 Installing On An Antenna Mast 1. Position the mounting pole on the antenna mast. 2. Insert the U-bolts around the mast and through the holes in the mounting pole. Install a washer and nut to each side of the threaded U-bolt and hand tighten. Repeat this step for the second U-bolt. 3. Tighten nuts equally until mounting pole is secure and cannot rotate. Typical 2 ½ inch Figure 5-4 Mounting Pole Installed on Pole or Antenna Mast Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-4 Company Proprietary 5.5.4 Installing On Brick Or Masonry 1. Place the mounting plate against the wall. Use a level or plumb line to set the mounting pole perpendicular to the ground. 2. Mark the hole locations. 3. Set the pole aside. 4. Drill ¼ inch holes at the marked locations. Drill the holes approximately ½ inch deep. 5. Insert the expansion shields into the drilled holes and tap them home. 6. Align the mounting pole with the drilled holes and fix with the lag bolts. Figure 5-5 Mounting Pole Installation 5.5.5 Installing On A Wall With Wood Siding 1. Place the mounting plate against the wall. 2. Using a level, be sure that the mounting pole is perpendicular to the ground. You may need to use spacers, as shown in Figure 5-6. 3. Mark the hole locations for the drilled hole locations. Remove the mounting pole and set aside. 4. Drill 1/8-inch holes in the places marked. 5. Use #10 or #12 wood screws to secure the mounting pole to the wall and tighten. Figure 5-6 Mounting Pole on Clapboard Siding Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-5 Company Proprietary 5.6 Mounting The Outdoor Access Points Now that you have installed the mounting pole, you are ready to install the Access Points onto the mounting poles. Reference Figures 5-7 through 5-10. Figure 5-7 Mounting Parts for an Outdoor Access Point 1. 2. 3. 4. 5. Place the outdoor Access Point on the mounting pole. Align the pole clamp with the mounting holes. Insert the mounting screws and hand tighten. Rotate the outdoor Access Point so it is pointing in the correct direction. Tighten the mounting screws. Serial Number Hex Bolts (2) Pole Brace MAC ADdress (underside) Figure 5-8 Access Point Rear View Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-6 Company Proprietary Tilt Bracket Side Hex Bolts Figure 5-9 Tilt Bracket Figure 5-10 Access Point with Mounted Tilt Bracket 5.6.1 Installing the Access Panel You will probably install the Access Panel in a rack, along with the anchor switch and other associated equipment. However, keep in mind that the access panel should be: • Located where you can easily connect to a power supply. • Close to the anchor switch. • Accessible for service and troubleshooting. • Protected from rain and extremes of temperature (it is designed for indoor use). 5.6.2 Installing The Interconnect Cables For each interconnect cable, you will need to perform the following steps. 5.6.2.1 Route The Cables 1. Select where the cable will enter the building from the outside. 2. Determine the length of cable required. Allow three extra feet on each end to allow for strain relief, as well as any bends and turns. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-7 Company Proprietary 3. Route the cable. 5.6.2.2 Install the Interconnect Cables (Transceiver End) 1. Remove the grommet and clamping plate from the outdoor transceiver by removing the two screws. Figure 5-11 Grommet Location - Underside of Access Point NOTE: The Grommet is made of a special conductive material used to complete the ground between the Access Point and Access Panel. 2. Insert the cable end through the grommet clamping plate (Figure 5-11) 3. Insert the cable end through the grommet. The tapered end of the grommet should be opposite the cable end. 4. Strip 1 inch of insulation off the cable end. Leave 3/8 inch of shielding showing and trim the wire ends flat ½ inch from there. 5. Using a piece of 1 inch squared tinned copper foil, wrap the foil around the shield/braid and sheath with the left edge aligned with the edge of the braid, as shown in the following Figures 5-12 and 5-13. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-8 Company Proprietary 1" square tinned copper foil - wrap the copper foil around the shield/braid and sheath with the left edge aligned with the edge of the braid. Insert wire into channels Tab on underside Shielding 3/8" Pin 1 Note direction of taper Grommet clamping plate Grommet 1/2" Grommet is conductive and used to complete the ground Figure 5-12 Outdoor Transceiver End of the Interconnect Cable with Cable Preparation Figure 5-13 Outdoor Transceiver End of the Interconnect Cable with Shielding 6. Separate the twisted pair wires and align by color code in the order listed in the following Table 5-3. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-9 Company Proprietary Table 5-3 Cable Legend for Interconnect Cable Pin Color Code White / Orange Orange White / Green Blue White / Blue Green White / Brown Brown 7. Using pin 1 as a reference, insert the individual wires into the channels of the RJ-45 connector. Each wire should penetrate the channels until flush with the connector end. The copper foil tape should extend past the casing of the RJ-45 connector by approximately ½ inch. 8. When all wires are inserted into the channels in their correct order, use the crimping tool to Permanently crimp the wires to the connector. Insert the RJ-45 connector into the receptacle located underneath the outdoor AP. Make sure that the connector tab engages the slot in the receptacle. 9. Slide the grommet up the cable and press it into the bottom of the outdoor AP. 10. Slide the grommet clamp up the cable and align the holes with the mounting holes on the bottom of the outdoor transceiver. 11. Insert the two screws in the mounting holes and tighten until the grommet has a slight bulge. Be sure to tighten both screws equally so that the grommet is seated correctly. 12. Secure the interconnect cable to the mounting pole with the cable clip as shown in Figure 5-14. Attention! Carefully read the instructions for the crimping tool you are using. Use the correct crimping tool for the RJ-45 connector you are using. Incorrect installation of the RJ-45 connector may result in a bad connection between the outdoor transceiver and the indoor junction box. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-10 Company Proprietary Figure 5-14 Interconnect Cable Installation to Outdoor Access Point - Bottom View 5.6.2.3 Installing The Interconnect Cables to Access Panel Attention! Always Disconnect Power from wall box BEFORE inserting RJ-45 connector into transceiver. This prevents arcing damage from occurring. 1. Install an RJ-45 connector to the junction box end of the cable, following the previous steps 6 through 12. 2. Plug the RJ-45 into one of the upper ports in the Access Panel junction box. RJ-45 to Access Point Transceiver GND Figure 5-15 Access Panel showing Connections to Access Point Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-11 Company Proprietary 5.6.2.4 Mark the Access Point Cables Attention! Step 1 is important, and will enable the network installer to configure the system easily. 1. Mark the cable with a permanent label and make a note so that the network installer knows which outdoor AP transceiver is connected to which port on the Access Panel junction box. 5.6.3 Grounding The System The AB-Access System must be properly grounded in order to protect it and the structure it is installed on from lightning damage. This requires: 1. Grounding all the outdoor transceivers as shown in Figure 5-14. 2. Grounding the Access Panel to the rack. 5.6.3.1 Grounding the Outdoor Access Points 1. Place the grounding rod so as to allow for the shortest possible path from the grounding cable to the outdoor Access Points. 2. Drive the grounding rod into the ground at least eight inches from the ground surface. 3. Attach a grounding clamp to the grounding rod. You will use this clamp to attach grounding wires for both the outdoor transceiver and indoor junction box, reference Figure 5-16. Figure 5-16 Ground Connections to Access Point Transceiver Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-12 Company Proprietary Attention! The grounding wire should be long enough to reach from the mounting pole to the grounding rod with 3 to 6 extra feet allowed for strain relief. 4. Connect a ground lug to one end of the grounding wire. 5. Remove one of the lower mounting screws of the mounting pole. Insert a screw through the grounding lug terminal and re-install it to the mounting pole. 6. Attach the grounding wire to the clamp on the grounding rod, reference Figure 5-17. If necessary, use wire staples to secure the grounding wire to the outside wall. Ground lug with #10 awg copper wire Figure 5-17 Mounting Pole with Ground Lug 7. Install a grounding wire from the junction box to the grounding rod. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 5-13 Company Proprietary SECTION 6 AB-Access Extender Installation 6 AB-Access Extender Installation 6.1 Before You Start This section lists the information you need on-hand before you can install a Base Station. 6.2 Information Required Before you perform the installation, a site survey should have been performed by the service provider. From this, you will need to know: • Number of EXs to install • Where the outdoor transceivers will be mounted (antenna mast, pole or building) • Heights at which the outdoor transceivers will be mounted. • Transceiver directional information (azimuth and elevation). IMPORTANT – Be sure to record for future reference the MAC address found on the EX unit BEFORE you install it. 6.2.1 Equipment Required Table 6-1 lists the tools and equipment you will need to install AB-Access Extender units. Table 6-1 Required Tools and Equipment Tools Required Compass and protractor Area map Phillips-head screwdriver Flat-head screwdriver Hammer or mallet Power drill 1/8 inch drill bit ¼ inch masonry drill bit Equipment Required ¼ inch grounding rod Grounding clamp Grounding wire CAT5 cable #6 wood screws Cable clips Anchor sleeves RJ-45 connectors (plastic bodied) 3/16 inch hex (Allen) wrench Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-1 Company Proprietary or 10 mm Bubble level or plumb line Adjustable wrench Wire snake (if routing cable through interior walls) Crimping tool (must be specifically matched for the RJ-45 connector used) Wire stripper Small wire cutters Punch down tool TBD: Update this section for AB-Access Extender 6.3 AB-Access Extender Table 6-2 lists the main components of an AB-Access Extender. Table 6-2 EX Components Item Quantity Outdoor transceiver Mounting pole Pole clamp M6 washer M3 x M10 machine thread screws 2 Grounding lug Indoor junction box Power supply and cord TBD: Update this section for AB-Access Extender Notes See item 1 in Figure 6-2 See item 2 in Figure 6-2 See item 3 in Figure 6-2 See item 4 in Figure 6-2 See item 5 in Figure 6-2 See item 6 in Figure 6-2 6-way rack-mounted unit TBD: Update this section for AB-Access Extender – need image of Extender Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-2 Company Proprietary Figure 6-1 Outdoor AB-Access Extender Components 6.4 Indoor Patch Panel Figure 6-2 shows the Base Station Access Panel used as an indoor patch panel. AP/EX OUT AP/EX IN Figure 6-2 Access Panel used as Patch Panel 6.5 Installing The Equipment This section explains how to install an EX transceiver onto a variety of surfaces, connect them to the indoor junction box, and ground the system. 6.5.1 Overview Following are the installation steps you will perform: 6. Install the mounting poles. 7. Mount the outdoor transceivers. 8. Mount the access panel. 9. Ground the outdoor transceivers and access panel 10. Connect the interconnect cables. 6.5.2 Installing The Mounting Poles First install the mounting poles, on which you will mount the outdoor transceivers. Bear in mind the direction in which the transceivers will point. Attention! The mounting pole must be mounted in a vertical position. Failure to do so may result in improper alignment of the outdoor transceiver. If you need to tilt the transceiver down to avoid self-interference, you should use an (optional) tilt bracket. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-3 Company Proprietary Warning! The mounting pole must be grounded. See Grounding The System in Section 6.6.3. 6.5.3 Installing On An Antenna Mast TBD: Update this section for AB-Access Extender 4. Position the mounting pole on the antenna mast. 5. Insert the U-bolts around the mast and through the holes in the mounting pole. Install a washer and nut to each side of the threaded U-bolt and hand tighten. Repeat this step for the second U-bolt. 6. Tighten nuts equally until mounting pole is secure and cannot rotate. Typical 2 ½ inch Figure 6-3 Mounting Pole Installed on Pole or Antenna Mast 6.5.4 Installing On Brick Or Masonry 7. Place the mounting plate against the wall. Use a level or plumb line to set the mounting pole perpendicular to the ground. 8. Mark the hole locations. 9. Set the pole aside. 10. Drill ¼ inch holes at the marked locations. Drill the holes approximately ½ inch deep. 11. Insert the expansion shields into the drilled holes and tap them home. 12. Align the mounting pole with the drilled holes and fix with the lag bolts. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-4 Company Proprietary Figure 6-4 Mounting Pole Installation 6.5.5 Installing On A Wall With Wood Siding 6. Place the mounting plate against the wall. 7. Using a level, be sure that the mounting pole is perpendicular to the ground. You may need to use spacers, as shown in Figure 6-6. 8. Mark the hole locations for the drilled hole locations. Remove the mounting pole and set aside. 9. Drill 1/8-inch holes in the places marked. 10. Use #10 or #12 wood screws to secure the mounting pole to the wall and tighten. Figure 6-5 Mounting Pole on Clapboard Siding 6.6 Mounting The Outdoor AB-Access Extender Now that you have installed the mounting pole, you are ready to install the AB-Access Extender onto the mounting poles. Reference Figures 6-7 through 6-10. TBD: Update this section for AB-Access Extender – image of extender on mounting Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-5 Company Proprietary Figure 6-6 Mounting Parts for an Outdoor AB-Access Extender 6. Place the outdoor AB-Access Extender on the mounting pole. 7. Align the pole clamp with the mounting holes. 8. Insert the mounting screws and hand tighten. 9. Rotate the outdoor AB-Access Extender so it is pointing in the correct direction. 10. Tighten the mounting screws. TBD: Update this section for AB-Access Extender – photo of rear of Extender Figure 6-7 AB-Access Extender Rear View Tilt Bracket Side Hex Bolts Figure 6-8 Tilt Bracket TBD: Update this section for AB-Access Extender – insert photo of correct tilt bracket for Extender Figure 6-9 AB-Access Extender with Mounted Tilt Bracket Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-6 Company Proprietary TBD: Update this section for AB-Access Extender – insert photo of correct tilt bracket connected to Extender 6.6.1 Installing the Access Panel You will probably install the Access Panel in a rack, along with the anchor switch and other associated equipment. However, keep in mind that the access panel should be: • Located where you can easily connect to a power supply. • Close to the anchor switch. • Accessible for service and troubleshooting. • Protected from rain and extremes of temperature (it is designed for indoor use). 6.6.2 Installing The Interconnect Cables For each interconnect cable, you will need to perform the following steps. 6.6.2.1 Route The Cables 4. Select where the cable will enter the building from the outside. 5. Determine the length of cable required. Allow three extra feet on each end to allow for strain relief, as well as any bends and turns. 6. Route the cable. 6.6.2.2 Install the Interconnect Cables (Transceiver End) 3. Remove the grommet and clamping plate from the outdoor transceiver by removing the two screws. Figure 6-10 Grommet Location - Underside of AB-Access Extender Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-7 Company Proprietary TBD: Update this section for AB-Access Extender – insert graphic of underside of Extender showing cable routing NOTE: The Grommet is made of a special conductive material used to complete the ground between the AB-Access Extender and Access Panel. 4. Insert the cable end through the grommet clamping plate (Figure 6-11) 5. Insert the cable end through the grommet. The tapered end of the grommet should be opposite the cable end. 6. Strip 1 inch of insulation off the cable end. Leave 3/8 inch of shielding showing and trim the wire ends flat ½ inch from there. 7. Using a piece of 1 inch squared tinned copper foil, wrap the foil around the shield/braid and sheath with the left edge aligned with the edge of the braid, as shown in the following Figures 6-12 and 6-13. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-8 Company Proprietary 1" square tinned copper foil - wrap the copper foil around the shield/braid and sheath with the left edge aligned with the edge of the braid. Insert wire into channels Tab on underside Shielding 3/8" Pin 1 Note direction of taper Grommet clamping plate Grommet 1/2" Grommet is conductive and used to complete the ground Figure 6-11 Outdoor Transceiver End of the Interconnect Cable with Cable Preparation Figure 6-12 Outdoor Transceiver End of the Interconnect Cable with Shielding 6. Separate the twisted pair wires and align by color code in the order listed in the following Table 6-3. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-9 Company Proprietary Table 6-3 Cable Legend for Interconnect Cable Pin Color Code White / Orange Orange White / Green Blue White / Blue Green White / Brown Brown 7. Using pin 1 as a reference, insert the individual wires into the channels of the RJ-45 connector. Each wire should penetrate the channels until flush with the connector end. The copper foil tape should extend past the casing of the RJ-45 connector by approximately ½ inch. 8. When all wires are inserted into the channels in their correct order, use the crimping tool to Permanently crimp the wires to the connector. Insert the RJ-45 connector into the receptacle located underneath the outdoor EX. Make sure that the connector tab engages the slot in the receptacle. 13. Slide the grommet up the cable and press it into the bottom of the outdoor EX. 14. Slide the grommet clamp up the cable and align the holes with the mounting holes on the bottom of the outdoor transceiver. 15. Insert the two screws in the mounting holes and tighten until the grommet has a slight bulge. Be sure to tighten both screws equally so that the grommet is seated correctly. 16. Secure the interconnect cable to the mounting pole with the cable clip as shown in Figure 6-14. Attention! Carefully read the instructions for the crimping tool you are using. Use the correct crimping tool for the RJ-45 connector you are using. Incorrect installation of the RJ-45 connector may result in a bad connection between the outdoor transceiver and the indoor junction box. Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-10 Company Proprietary Figure 6-13 Interconnect Cable Installation to Outdoor AB-Access Extender - Bottom View TBD: Update this section for AB-Access Extender – insert graphic for AB-Access Extender bottom view with cable routing 6.6.2.3 Installing The Interconnect Cables to Access Panel Attention! Always Disconnect Power from wall box BEFORE inserting RJ-45 connector into transceiver. This prevents arcing damage from occurring. 3. Install an RJ-45 connector to the junction box end of the cable, following the previous steps 6 through 12. 4. Plug the RJ-45 into one of the upper ports in the Access Panel junction box. RJ-45 to AP/EX Transceiver GND Figure 6-14 Access Panel showing Connections to AP/EX Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-11 Company Proprietary 6.6.2.4 Mark the AB-Access Extender Cables Attention! Step 1 is important, and will enable the network installer to configure the system easily. 2. Mark the cable with a permanent label and make a note so that the network installer knows which outdoor EX transceiver is connected to which port on the Access Panel junction box. 6.6.3 Grounding The System The AB-Access System must be properly grounded in order to protect it and the structure it is installed on from lightning damage. This requires: 8. Grounding all the outdoor transceivers as shown in Figure 6-14. 9. Grounding the Access Panel to the rack. 6.6.3.1 Grounding the Outdoor AB-Access Extender 8. Place the grounding rod so as to allow for the shortest possible path from the grounding cable to the outdoor AB-Access Extender. 9. Drive the grounding rod into the ground at least eight inches from the ground surface. 10. Attach a grounding clamp to the grounding rod. You will use this clamp to attach grounding wires for both the outdoor transceiver and indoor junction box, reference Figure 6-16. Figure 6-15 Ground Connections to AB-Access Extender Transceiver Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-12 Company Proprietary Attention! The grounding wire should be long enough to reach from the mounting pole to the grounding rod with 3 to 6 extra feet allowed for strain relief. 11. Connect a ground lug to one end of the grounding wire. 12. Remove one of the lower mounting screws of the mounting pole. Insert a screw through the grounding lug terminal and re-install it to the mounting pole. 13. Attach the grounding wire to the clamp on the grounding rod, reference Figure 6-17. If necessary, use wire staples to secure the grounding wire to the outside wall. Ground lug with #10 awg copper wire Figure 6-16 Mounting Pole with Ground Lug Install grounding wire from the junction box to the grounding Adaptive Broadband U-NII Product Installation Manual 05/29/2001 rod. 6-13 Company Proprietary Adaptive Broadband U-NII Product Installation Manual 05/29/2001 6-1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2001:05:29 08:24:39 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2001:05:29 08:24:41-04:00 Page Count : 65EXIF Metadata provided by EXIF.tools