Contents
- 1. User Manual
- 2. User-Manual-Statement and Warning
User Manual
BF-IDU03 RFID-Reader Company Addresses Europe, Germany, Headquarter Balluff GmbH Schurwaldstraße 9 D-73765 Neuhausen, Germany Argentina Balluff Argentina S.R.L. Echeverría 1050, 1st UF 2 1604 Buenos Aires - Florida Oeste Australia Balluff Pty Ltd. 18 Malvern Street Bayswater, 3153 Victoria Brasil Balluff Controles Elétricos Ltda. Rua Francisco Foga, 25 ,Distrito Industrial CEP 13280.000 – Vinhedo – SP Canada Balluff Canada Inc. 2840 Argentia Road, Unit 2 Mississauga, Ontario L5N 8G4 China Balluff (Shanghai) Trading Co. Ltd. No.800 Chengshan Rd, 8F, Building A, Yunding International Commercial Plaza 200125, Pudong, Shanghai Japan Balluff Co., Ltd. Aqua Hakusan Bldg. 9F 1-13-7 Hakusan, Bunkyo-ku, Tokyo 113-0001 Mexico Balluff de México S.A. de C.V. Anillo Vial II Fray Junipero Serra No. 4416; Colonia La Vista Residencial CP 76232 Delegación Epigmenio González, Querétaro USA Balluff Inc. 8125 Holton Drive, Florence Kentucky 41042-0937 BF-IDU03 RFID-Reader Operating Guide Purpose of the Device The BF-IDU03 device is intended to read and write "EPC Global Class 1 Gen2" compliant data carriers (so called tags) via country dependent UHF radio frequencies. Check that you have the right device variant This UHF system consists of a radio frequency unit and an integrated antenna according to specifications and may only be operated within the specified countries subject to all applicable national legal regulations and standards. Check that the type label contains the correct type approval symbol for your country. ► When using the UHF system in the European Community, the provisions in ETSI standard 302 208 apply. ► When using the UHF system in the USA, the directives of the FCC, Part 15 B and 15 C, apply. ► When using the UHF system in Canada, the directives of the IC, RSS-210 apply. ► When using the UHF system in Mexico, the directives of the SCT, NOM-121-SCT1-2009 apply. ► When using the UHF system in Argentina, the directives of Resolución SC 729/80 and SC 784/87 apply. ► When using the UHF system in Brazil, the directives of the ANATEL, 506/2008 and 442/2006 apply. ► When using the UHF system in China, the directives of the RFID National Standard and GB 9254 apply. ► When using the UHF system in Japan, the directives of "Radio Law" and ARIB T106 apply. ► When using the UHF system in Australia, the directives of the Radiocommunications Class License 2000 (Item 32A) apply. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. BF-IDU03 RFID-Reader Connecting the Device The device has to be connected to one of the head connectors "H1" .. "H4" of a Balluff BIS V control unit via standard 4-wire cable with M12 industry connectors. The control unit delivers power supply and controls the device over this connection. Make an additional ground connection to the Functional Ground terminal (Symbol directly or using an RC combination to ground. BF-IDU03 ) either BIS V-6xxx The control unit itself needs to be connected to a power supply and the customer's PLC unit. See the BIS V manual for details. Mounting Before operating, the device has to be fixed mounted with at least 2 screws of M4 or M5 size in mounting holes at back side (see image). The BF-IDU03 device may be mounted in any direction, the operating direction of the integrated antenna is towards the front containing the "BIS VU Identification Systems" label. Optional mounting plates are available for installing the device. The antennas of the identification system BIS U transmit ultra-high frequency electromagnetic waves. People should not remain within close range of the UHF antenna for long periods (several hours). When selecting the installation position for the BF-IDU03 device, make sure that the minimum distance between the UHF antenna and the workplace is 25 cm. BF-IDU03 RFID-Reader Setup and Operation The BF-IDU03 device will operate when the BIS V control unit receives read or write commands from the connected PLC. See the manual of BIS V control units for how to send commands to the control unit. The transmission power may be set up with Service Software e.g. "Balluff UHF Manager" up to the specified maximum to control the read and write range of the device. Status Indicators The device will show its status using the 4 LEDs at the corners of the housing. In normal operation state the meaning of these lights are as follows: ► Green light "Power" indicates that the device is connected to the control unit and ready to operate. ► Red light "Status" (permanent) indicates that the device's temperature is outside limits, probably because the ambient temperature is too high or the device is defective. ► Red light "Status" (flashing) indicates that the devices settings are not initialized correctly. Please contact Service. ► Blue light "RF active" indicates that the device has turned radio frequency transmission on and tries to scan for tags or write or read data over the air. ► Orange light "Tag present" indicates that at least one UHF EPC Global tag could be found by the device. The light will stay on for at least 3 seconds after a successful scan. Electrical Data Operating voltage Vs Current draw (at 24 V DC) USA / Canada / Mexico Version: Operating Frequency Maximum Transmit Power Republic of Korea Version: Operating Frequency Maximum Transmit Power China Version: Operating Frequency Maximum Transmit Power Japan Version: Operating Frequency Maximum Transmit Power Australia Version: Operating Frequency Maximum Transmit Power Maximum Read Range Antenna Beam Opening Angle Antenna Polarization 19.2…28.8 V DC ≤ 200 mA 902 .. 928 MHz < 30 dBm (1 W) EIRP 917 .. 921 MHz 27 dBm (0,5 W) EIRP 920.5 .. 924.5 MHz 25 dBm (0,32 W) ERP 916.7 .. 920.5 MHz 27 dBm (0,5 W) EIRP 920 .. 926 MHz 27 dBm (0,5 W) EIRP 1000 mm 90° (horizontal/vertical) Circular LH Mechanical Data Housing material: Metal / ABS / PC, weight: 850 g, ambient temperature range: -20°C .. +55°C, device size: width x height x depth = 130 mm x 130 mm x 50.5 mm
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2018:04:06 08:12:21+02:00 Creator : Microsoft® Word 2010 Modify Date : 2018:04:16 21:12:45+08:00 Language : de-DE XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : Microsoft® Word 2010 Metadata Date : 2018:04:16 21:12:45+08:00 Producer : Microsoft® Word 2010 Format : application/pdf Document ID : uuid:cb1b31b5-f15e-4fba-bd11-d6e56e4f6e36 Instance ID : uuid:49fcc5de-7715-43ad-b39e-5d3c8df320e7 Page Count : 4EXIF Metadata provided by EXIF.tools