CalAmp Wireless Networks BDP4-EXCT438 UHF HIGH SDR Exciter for BDP4 digital base station User Manual 120 20195 100 P4 700 May21x

CALAMP WIRELESS NETWORKS INC. UHF HIGH SDR Exciter for BDP4 digital base station 120 20195 100 P4 700 May21x

user manual

  AERCEPTDATARADIOLANDCELLOMEGASMARTLINK299JohnsonAvenue,Suite110|Waseca,MN56093|t507.833.8819|f507.833.6748|calamp.com          Dataradio PPaarraaggoonn44 Data Base Station UHF, 700, and 800 MHz with Crescend Power Amplifier  User Manual  P/N 001-2019-500 Revision 0 May 2010   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   ii  1.PREFACE..............................................................................................................................................................................V1.1COPYRIGHTNOTICE.......................................................................................................................................................................V1.2USERMANUALSTATEMENT............................................................................................................................................................V2.DEFINITIONS.......................................................................................................................................................................VI3.PRODUCTOVERVIEW............................................................................................................................................................13.1INTENDEDAUDIENCE.....................................................................................................................................................................13.2GENERALDESCRIPTION...................................................................................................................................................................13.3SERVICEANDSUPPORT...................................................................................................................................................................33.4PACKAGING..................................................................................................................................................................................44.INSTALLATION.......................................................................................................................................................................54.1OVERVIEW...................................................................................................................................................................................54.2LOCATION....................................................................................................................................................................................54.3REARVIEWS.................................................................................................................................................................................64.4ELECTRICALCONFIGURATIONS..........................................................................................................................................................74.5ANTENNA..................................................................................................................................................................................124.6COMPLETINGTHEPHYSICALINSTALLATION........................................................................................................................................124.7CHECKINGOUTNORMALOPERATION..............................................................................................................................................125.OPERATINGDESCRIPTION...................................................................................................................................................135.1RADIOASSEMBLY........................................................................................................................................................................136.OPERATION&CONFIGURATION..........................................................................................................................................186.1BROWSER‐BASEDINTERFACE.........................................................................................................................................................186.3IPNETWORKCONFIGURATION.......................................................................................................................................................196.4WEBSERVERLOGIN.....................................................................................................................................................................216.5WEBINTERFACE..........................................................................................................................................................................226.6UNITSTATUS..............................................................................................................................................................................236.7SETUP(BASIC)............................................................................................................................................................................296.8SETUP(ADVANCED).....................................................................................................................................................................346.9SECURITY...................................................................................................................................................................................656.10STATISTICS.................................................................................................................................................................................676.11MAINTENANCE...........................................................................................................................................................................736.12OOBDATA(OUTOFBANDGPSDELIVERY)......................................................................................................................................816.13REMOTETABLE...........................................................................................................................................................................826.14SITEMAPANDHELP....................................................................................................................................................................847.TROUBLESHOOTINGANDTESTING......................................................................................................................................857.1EQUIPMENTREQUIRED.................................................................................................................................................................857.2RECOMMENDEDCHECKS...............................................................................................................................................................857.3ADDITIONALTESTDETAILS.............................................................................................................................................................907.4WINDOWS/UNIXTOOLS...............................................................................................................................................................927.5BSCFIRMWAREUPGRADING.........................................................................................................................................................938.SPECIFICATIONS..................................................................................................................................................................95    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   iiiFIGURE 1 - FRONT VIEW "RADIO ASSEMBLY" ............................................................................................................................................. 5FIGURE 2 - TYPICAL RACKMOUNT INSTALLATION OF RADIO MODEM AND CRESCEND PA .......................................................................... 5FIGURE 6 - PARAGON4 UNIT REAR VIEW ..................................................................................................................................................... 6FIGURE 7 - BACKPLANE .............................................................................................................................................................................. 6FIGURE 5 – SIMPLE AC-TO-DC POWER SUPPLY CONFIGURATIONS: BLOCK DIAGRAM ................................................................................ 7FIGURE 6 – SIMPLE AC-TO-DC POWER SUPPLY CONFIGURATIONS: VIRTUAL RACK-MOUNT INSTALLATION ............................................... 8FIGURE 10 - SCREW REMOVAL DETAIL ........................................................................................................................................................ 9FIGURE 11 - FUSES LOCATION .................................................................................................................................................................... 9FIGURE 13 - MAXI-FUSE ........................................................................................................................................................................... 11FIGURE 18 - WEB INTERFACE ................................................................................................................................................................... 18FIGURE 19 - IP NETWORK SETTINGS IN ROUTER MODE (WITH HOST) ...................................................................................................... 20FIGURE 20 - IP NETWORK SETTINGS IN ROUTER MODE (WITH ROUTER) .................................................................................................. 20FIGURE 21 - WEB USER INTERFACE – WELCOME SCREEN ........................................................................................................................ 21FIGURE 22 - UNIT IDENTIFICATION AND STATUS ...................................................................................................................................... 23FIGURE 23 - UNIT STATUS - RADIO INFORMATION ................................................................................................................................... 24FIGURE 24 - UNIT STATUS – DIAGNOSTICS ............................................................................................................................................... 26FIGURE 19 - BACKPLANE -TB1 CONNECTOR ............................................................................................................................................. 28FIGURE 20 - TB1 CONNECTOR .................................................................................................................................................................. 28FIGURE 25 - SETUP (BASIC) – GENERAL SETUP ........................................................................................................................................ 29FIGURE 26 - SETUP (BASIC) – BASIC IP CONFIGURATION ......................................................................................................................... 30FIGURE 27 - RF (FREQUENCIES) ............................................................................................................................................................... 31FIGURE 28 - SETUP (BASIC) – SERIAL PORTS SETUP ................................................................................................................................. 33FIGURE 29 - ADVANCED IP CONFIGURATION - LAN (IP) ......................................................................................................................... 34FIGURE 30 - ADVANCED IP CONFIGURATION - RF (IP) ............................................................................................................................. 35FIGURE 31 - ADVANCED IP CONFIGURATION – ROAMING ........................................................................................................................ 36FIGURE 32 - ADVANCED IP CONFIGURATION – IP SERVICES SETUP ......................................................................................................... 37FIGURE 33 - NAT ENABLED ON PARAGON4 ............................................................................................................................................. 39FIGURE 34 - PARAGON4 - EXAMPLE 1 ....................................................................................................................................................... 39FIGURE 35 - PARAGON4 - EXAMPLE 2 ....................................................................................................................................................... 40FIGURE 36 - PARAGON4 - EXAMPLE 3 ....................................................................................................................................................... 40FIGURE 37 - PARAGON4 - EXAMPLE 4 ....................................................................................................................................................... 41FIGURE 38 - NAT ENABLED ON GEMINIG3 .............................................................................................................................................. 41FIGURE 39 - GEMINIG3 - EXAMPLE 1 ........................................................................................................................................................ 42FIGURE 40 - GEMINIG3 - EXAMPLE 2 ........................................................................................................................................................ 42FIGURE 41 - SNMP: MANAGER/AGENT MODEL ......................................................................................................................................... 43FIGURE 42 - BRANCH OF THE 1234.MIB OID TREE .................................................................................................................................... 44FIGURE 43 - BSC.MIB TREE ....................................................................................................................................................................... 45FIGURE 44 - ADVANCED IP CONFIGURATION – IP ADDRESSING MODES .................................................................................................... 46FIGURE 45 - BROADCAST WINDOW DETAIL .............................................................................................................................................. 48FIGURE 46 - EXAMPLE OF DIRECTED BROADCAST FORWARDING ENABLED .............................................................................................. 49FIGURE 47 - EXAMPLE OF DIRECTED BROADCAST FORWARDING DISABLED ............................................................................................. 50FIGURE 48 - EXAMPLE OF DIRECTED BROADCAST FORWARDING ENABLED .............................................................................................. 51FIGURE 49 - EXAMPLE OF LIMITED BROADCAST FORWARDING DISABLED ................................................................................................ 52FIGURE 50 - REGISTRATION TO MULTICAST GROUP (FIRST STEP) ..............................................................................................................  53FIGURE 51 - RECEPTION OF MULTICAST PACKETS (SECOND STEP) ............................................................................................................ 53FIGURE 52 - TYPICAL E-DBA MULTICAST GROUPS ................................................................................................................................. 54FIGURE 53 - MULTICAST WINDOW DETAILS (ON THE BASE STATION) ..................................................................................................... 55FIGURE 54 - TYPICAL E-DBA MULTICAST GROUPS (WITH ADDRESSES) ................................................................................................... 55FIGURE 55 - SETUP (ADVANCED)-OPTIMIZED IP SETTINGS ...................................................................................................................... 56FIGURE 56 - IP ROUTING........................................................................................................................................................................... 57FIGURE 57 - ADVANCED IP CONFIGURATION – TIME SOURCE .................................................................................................................. 58FIGURE 58 - ADVANCED IP CONFIGURATION – ETHERNET (PHY) ............................................................................................................  59FIGURE 59 - ADVANCED IP CONFIGURATION – DIAGNOSTIC SETTINGS ....................................................................................................  60FIGURE 60 - SAMPLE INTERPOLATION CURVE ........................................................................................................................................... 62FIGURE 61 - SAMPLE CALIBRATION FILE ................................................................................................................................................... 63FIGURE 62 - ADVANCED IP CONFIGURATION - USER SETTINGS ................................................................................................................  64Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   ivFIGURE 63 - SECURITY – PASSWORD AND ENCRYPTION ........................................................................................................................... 65FIGURE 64 - SECURITY - ACCESS LIST ...................................................................................................................................................... 66FIGURE 65 - STATISTICS – INTERFACES ..................................................................................................................................................... 67FIGURE 66 - LAYERS AND PROTOCOLS APPLICABLE TO DATARADIO IMPLEMENTATION ........................................................................... 68FIGURE 67 - LAYER, PROTOCOLS, AND INTERFACES APPLICABLE TO DATARADIO IMPLEMENTATION ....................................................... 69FIGURE 68 - RX AND TX CONVENTION .................................................................................................................................................... 69FIGURE 69 - DATALINK ETHERNET STATISTICS ........................................................................................................................................ 70FIGURE 70 - DATALINK RF STATISTICS .................................................................................................................................................... 70FIGURE 71 - STATISTICS - SYSTEM PERFORMANCE ................................................................................................................................... 71FIGURE 72 - MAINTENANCE – PING TEST ................................................................................................................................................. 73FIGURE 73 - MAINTENANCE -CONFIGURATION CONTROL (INITIAL SCREEN) ............................................................................................ 74FIGURE 74 - MAINTENANCE – PACKAGE CONTROL .................................................................................................................................. 75FIGURE 75 - CONTROL - RF TESTS ............................................................................................................................................................ 76FIGURE 76- MAINTENANCE – AVAILABLE FEATURE OPTIONS .................................................................................................................. 78FIGURE 77 - MAINTENANCE – RSSI DISPLAY ........................................................................................................................................... 78FIGURE 78 - MAINTENANCE –SYSTEM LOG .............................................................................................................................................. 79FIGURE 79 - A SYSTEM LOG ENTRY .......................................................................................................................................................... 79FIGURE 80 - AN ASSERT TYPE SYSTEM LOG ENTRY ................................................................................................................................... 80FIGURE 81 - OUT-OF-BAND ...................................................................................................................................................................... 81FIGURE 82 - REMOTE TABLE ..................................................................................................................................................................... 82FIGURE 83 - HELP ICON ............................................................................................................................................................................ 84FIGURE 84 - PF SWITCH ROCKER DETAIL (ONE SIDE PRESSED) ................................................................................................................. 90FIGURE 85 - SAMPLE FTP PROGRAM ......................................................................................................................................................... 94 TABLE 1 - ON-AIR DATA SPEEDS AND MODULATION ................................................................................................................................... 2TABLE 2 - TEST POINTS .............................................................................................................................................................................. 7TABLE 4 - POWER AMPLIFIER INDICATORS ............................................................................................................................................... 15TABLE 3 - ICT N+1LED MODULE STATUS DISPLAY ................................................................................................................................ 16TABLE 5 - SAMPLE INTERPOLATION ENDPOINTS ....................................................................................................................................... 62TABLE 6 - PLICC SYNTAX ....................................................................................................................................................................... 63TABLE 7 - POSSIBLE ERROR MESSAGES..................................................................................................................................................... 63TABLE 8 - CHECKLIST A (AFTER INSTALLATION) ..................................................................................................................................... 86TABLE 9 - CHECKLIST B (GENERAL) ......................................................................................................................................................... 87TABLE 10 - CARRIER DEVIATIONS ............................................................................................................................................................ 90TABLE 11 - TEST TONES GENERATION ..................................................................................................................................................... 91  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   v1. PREFACE 1.1 Copyright Notice ©2010 CalAmp Corp. All Rights Reserved.  This manual covers the operation of the CalAmp/ Dataradio Paragon4 data base station.  Specifications described are typ-ical only and are subject to normal manufacturing and service tolerances.  CalAmp reserves the right to modify the equipment, its specifications or this manual without prior notice, in the interest of improving performance, reliability, or servicing. At the time of publication all data is correct for the operation of the equipment at the voltage and/or temperature referred to. Performance data indicates typical values related to the particular product. No part of this documentation or information supplied may be divulged to any third party without the express written con-sent of CalAmp Corp. Products offered may contain software which is proprietary to CalAmp Corp. The offer or supply of these products and services does not include or infer any transfer of ownership. 1.2  User Manual Statement  Every effort is taken to provide accurate, timely product information in this user manual.  Product updates may result in differences between the information provided herein and the product shipped. The informa-tion in this document is subject to change without notice.  www.CalAmp.com For additional information, please visit http://www.calamp.com        Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   vi2. Definitions  Access Point  Communication hub for users to connect to a wired LAN. APs are important for providing heigh-tened wireless security.  ADB  Agile Dual-Band - GeminiG3 radiomodem model that allows 700/800MHz automatic band switching capability during roaming. AES  Advanced Encryption Standard (AES) - uses 128-bit encryption to secure data. Airlink   Physical radio frequency connections used for communications between units. ARP   Address Resolution Protocol – Maps Internet address to physical address. AAVL  Autonomous Automatic Vehicle Location. Optional feature that involves using GPS (Global Po-sitioning System) signals from the mobile unit by the Host PC.  Backbone   The part of a network that connects most of the systems and networks together, and handles the most data. Bandwidth   The transmission capacity of a given device or network. Base  Designates products used as base stations in VIS systems. They currently include the Paragon family of products up to the Paragon4 radiomodems.  Browser   An application program that provides a way to look at and interact with all the information on the World Wide Web. BSC  Base Station Controller - An async controller-modem designed for the radio base station in mo-bile systems. A component of Paragon4 radiomodem base stations.  COM Port  RS-232 serial communications ports of the Paragon4 wireless radiomodem.  Cycle Mark   Signal transmitted on an E-DBA network that keeps the network synchronized.  Default Gateway   A device that forwards Internet traffic from your local area network. DHCP   Dynamic Host Configuration Protocol - A networking protocol that allows administrators to as-sign temporary IP addresses to network computers by "leasing" an IP address to a user for a li-mited amount of time, instead of assigning permanent IP addresses. DNS   Domain Name Server - The on-line distributed database system used to map human-readable ma-chine names into IP addresses. Domain   A specific name for a network of computers. Dynamic IP Addr  A temporary IP address assigned by a DHCP server. E-DBA  Enhanced Dynamic Bandwidth Allocation – Dataradio proprietary protocol that schedules all in-bound and outbound Airlink traffic to minimize contention. Ethernet   Ethernet is a frame-based computer networking technology for local area networks (LANs). It de-fines wiring and signaling for the physical layer, and frame formats and protocols for the media access control (MAC)/data link layer of the OSI model. Ethernet is mostly standardized as IEEEs 802.3. Feature Key  Method used to implement customer’s option(s) selected at the time of radiomodem purchase (factory-installation) or as add-on (field-installation). Firewall   A set of related programs located at a network gateway server that protects the resources of a network from users from other networks. Firmware   The programming code that runs a networking device. Fragmentation  Breaking a packet into smaller units when transmitting over a network medium that cannot sup-port the original size of the packet. FTP   File Transfer Protocol - A protocol used to transfer files over a TCP/IP network. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   viiGateway   A device that interconnects two or more networks with different, incompatible communications protocols and translates among them. GeminiG3  Third generation of GeminiPD VIS products. High specs dual DSP mobile radiomodem with Data-radio Parallel Decode™ technology  HDX  Half Duplex. Data transmission that can occur in two directions over a single line, using separate Tx and Rx frequencies, but only one direction at a time. HTTP   HyperText Transport Protocol - The communications protocol used to connect to servers on the World Wide Web. IPCONFIG   A Windows 2000 and XP utility that displays the IP address for a particular networking device. MAC ADDRESS  Media Access Control - The unique address that a manufacturer assigns to each networking de-vice. MIB   Management Information Base (MIB)-a logical, hierarchically organized database of network management information. Used in SNMP. NAT   Network Address Translation - NAT technology translates IP addresses of a local area network to a different IP address for the Internet. Network   A series of computers or devices connected for the purpose of data sharing, storage, and/or transmission between users. Network speed  This is the bit rate on the RF link between units.  Node   A network junction or connection point, typically a computer or work station. OID  An object identifier or OID is an identifier used to name an object and is the numerical equivalent of a path. In SNMP, an OID consists of numbers separated by decimal points. Structurally, an OID consists of a node in a hierarchically assigned namespace. OIP  Optimized IP – Compresses TCP and UDP headers, and filters unnecessary acknowledgments. This makes the most use of the available bandwidth. OTA  Over-The-Air - Standard for the transmission and reception of application-related information in a wireless communications system Palette   Synchronization patterns used to identify the speed and coding of packets transmitted over-the-air in E-DBA. Paragon4 IP-based data radio base station used in mobile networks and designed specifically to fit the needs of vehicular applications. Runs up to 128 kb/s Parallel Decode  Technology featuring dual receivers for added data decode sensitivity in multi-path and fading environments. (United States Patent No: 6,853,694 B1) PHY  A PHY chip (called PHYceiver) provides interface to the Ethernet transmission medium. Its pur-pose is digital access of the modulated link (usually used together with an MII-chip).  The PHY defines data rates and transmission method parameters. PDU  Protocol Data Unit - A PDU is a message of a given protocol comprising payload and protocol-specific control information, typically contained in a header. PDUs pass over the protocol inter-faces that exist between the layers of protocols. Ping   Packet INternet Groper - An Internet utility used to determine whether a particular IP address is online. PLC  Programmable Logic Controller. An user-provided intelligent device that can make decisions, gather and report information, and control other devices. Roaming  Movement of a wireless node (GeminiG3 radiomodems) amongst Multiple Access Points (Para-gon4). Paragon4 radiomodems support seamless roaming. Router   A networking device that connects multiple networks together. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   viiiRS-232  Industry–standard interface for data transfer.  Smart Combining  Digital processing method used to combine “Spatial Diversity” signals to optimize performance. (See Parallel Decode) SNMP   Simple Network Management Protocol - Provides a means to monitor and control network devic-es, and to manage configurations, statistics collection, performance, and security. Spatial Diversity  Composite information from independent diversity branches using antennas spaced apart is used with “Smart Combining” to minimize fading and other undesirable effects of multipath propaga-tion. (See Parallel Decode) SRRCnFSK  Square Root Raised Cosine (n = level) Frequency Shift Keying. Type of frequency modulation of data signals performed by the Paragon4 radiomodem. Static IP Address   A fixed address assigned to a computer or device that is connected to a network. Static Routing   Forwarding data in a network via a fixed path. Subnet Mask   A bit mask used to select the bits from an IP address that correspond to the subnet. Each mask is 32 bits long, with one bits in the portion that identifies a network and zero bits in the portion that identifies a host. Switch (Ethernet)  Computer-networking device that allows sharing a limited number of ports to connect computing devices to host computers. Replaces network hubs (layer1),  switches (layer2), routers (layer3).  Sync   Data transmitted on a wireless network that keeps the network synchronized.  TCP/IP   Transmission Control Protocol/Internet Protocol - A transport (layer4) protocol for transmitting data that requires acknowledgement from the recipient of data sent. Handles retries and flow con-trol. Telnet   Network (layer5) protocol used on the Internet or on LAN connections. TFTP   Trivial File Transfer Protocol - A version of the TCP/IP FTP protocol that has no directory or password capability. Topology   The physical layout of a network. Transparent  A transparent unit transmits all data without regard to special characters, etc. UDP   User Datagram Protocol - A transport (layer4) protocol for transmitting data that does not require acknowledgement from the recipient of the data that is sent. Upgrade   To replace existing software or firmware with a newer version. URL   Universal Resource Locator - The address of a file located on the Internet. VIS  Vehicular Information Solutions. Dataradio’s name for a series of products specially designed for mobile data. WLAN   Wireless Local Area Network - A group of computers and associated devices that communicate with each other wirelessly.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   13. PRODUCT OVERVIEW This document provides information required for the setting up, operation, testing and trouble-shooting of the Dataradio® Paragon4™ radio-modem base station.  3.1 Intended Audience This document is intended for engineering, installation, and maintenance personnel. 3.2 General Description The Paragon4 radio base station is a factory-integrated industrial-grade IP-based data product used in mobile networks and is designed specifically to fit the needs of vehicular applications. It features dual receivers for added data decode sensitivity in multi-path and fading environments. When used with Dataradio’s state-of-the-art GeminiG3 mobile IP data solution, the system delivers unequaled high-speed data performance and unmatched effective throughput.  All Paragon4 models are supplied in a standard 19-inch wide rackmount. The Paragon4 full-duplex radio-modem chassis assembly includes: • A second generation high-speed Dataradio “Base Station Controller” module (BSC2) that uses an open architecture that simplifies the implementation process. The BSC2 module comes equipped with a built-in IP router with dual Ethernet 10/100 BaseT interfaces.  • Option for internally/externally generated high-stability (+/-0.1ppm) 10MHz reference source, factory installed. • Dual, independently synthesized Receiver radio module. • High-performance synthesized 0.2W Exciter radio module. For all Paragon4 radio modem units: • One Power Amplifier (PA) module is required for the regular usage.     • Duplexer and backup power units are custom furnished items.  • Wire line modem(s) are optional items.  • Laptop PC and its application software are user-supplied items. • Optional Router – Adding a second router anywhere within a network is required to make it fault tolerant.   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   23.2.1 Features • Parallel Decode™ technology featuring dual receivers for added decode sensitivity in multi-path and fading environments. • Fully IP-based product models, using an Optimized IP layer that reduces IP overhead for the RF link • Sophisticated dual DSP-based modem design provides added system performance, fewer retries and more effective throughput. • Full duplex mode of operation  • Base Station with an RF Power Amplifier. The Power Amplifier is considered a stand-alone module.  • On-air data speeds and modulation types supported (dependent on “Feature Key” selected1): Table 1 - On-air data speeds and modulation   Channel Type UHF  700 MHz   800 MHZ Modulation type  25 kHz  12.5 kHz 50 kHz  25 kHz  12.5 kHz 25 kHz   NPSPACSRC16FSK  64 kb/s  32 kb/s  128 kb/s  64 kb/s   32kb/s  64 kb/s  32kb/s SRC8FSK  48 kb/s  24 kb/s   96kb/s   48kb/s   24kb/s  48 kb/s  24kb/s 43.2 kb/s  43.2kb/s  43.2 kb/s SRC4FSK  32 kb/s  16 kb/s   64kb/s  32 kb/s   16kb/s  32 kb/s  16kb/s • Uses Dataradio’s Next generation high-efficiency Enhanced-DBA (E-DBA) over-the-air protocol • Over-the-air compatible with GeminiG3 mobile products • Out-of-band signaling enables transmission of GPS reports with no effect on system performance. • Flash programmable firmware 3.2.2 Configuration Paragon4 units are factory-configured based on each customer’s individual system requirements. Net-work-specific installation and/or operating instructions should be prepared in conjunction with Dataradio System Engineering department, which also handles field deployment.  Instructions and examples given in this manual are based on Paragon4 operating software version current at the time of writing this document and may not apply to earlier or later software versions. Screen cap-tures used throughout this document may vary from actual screens. Configuration changes or upgrades are web-based.                                                1 Method used to implement customer’s option(s) selected at the time of radiomodem purchase (factory-installation) or as add-on (field-installation). Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   33.3 Service and Support 3.3.1  Product, Warranty, RMA and Contact Information CalAmp Corp guarantees that every DataradioParagon4 base station will be free from physical defects in material and workmanship for one (1) year from the date of purchase when used within the limits set forth in the Specifications section of this manual. Extended warranty plans are available.  If the product proves defective during the warranty period, contact CalAmp Customer Service to obtain a Return Material Authorization (RMA).  3.3.1.1 RMA Request Contact Customer Service: CalAmp – Dataradio  299 Johnson Avenue, Suite 110 Waseca, MN 59093-USA phone:  (1) 507.833.8819                                                                                      fax:       (1) 507.833.6748                                                                                                     BE SURE TO HAVE THE EQUIPMENT MODEL AND SERIAL NUMBER, AND BILLING AND SHIPPING ADDRESSES ON HAND WHEN CALLING.  When returning a product, mark the RMA clearly on the outside of the package. Include a complete de-scription of the problem and the name and telephone number of a contact person. RETURN REQUESTS WILL NOT BE PROCESSED WITHOUT THIS INFORMATION. For units in warranty, customers are responsible for shipping charges to CalAmp Corp. For units returned out of warranty, customers are responsible for all shipping charges. Return shipping instructions are the responsibility of the customer. 3.3.2 Product Documentation CalAmp Corp reserves the right to update its products, software, or documentation without obligation to notify any individual or entity. Product updates may result in differences between the information pro-vided in this manual and the product shipped. For the most current product documentation, visit www.calamp.com for spec sheets. 3.3.3 Technical Support Technical support hours: Monday to Friday 9:00 AM to 5:00 PM, Eastern Time CalAmp – Dataradio Corp                                                                                                        6160 Peachtree Dunwoody RD., suite C-200                                                                                              Atlanta, Georgia 3032 phone:  (1) 770.392.0002                                                                                                                                  fax:       (1) 770.392.9199                                                                                                                                  Email address: PSMGsupport@calamp.com    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   43.4  Packaging Each Paragon4 radio-modem base station – UHF, 700, or 800MHz – normally leaves the factory pack-aged as follows: • A Dataradio base station “Radio-modem assembly”. • A Crescend 70W (for 700 and 800 MHz) or 100W (for UHF) rack-mount power amplifier mod-ule. • An ICT 13.8VDC 34A AC/DC rack-mount power supply, if ordered that way. • One six-foot 120VAC power cord (NEMA 5-15p plug to IEC 60320-C19 receptacle) for the AC/DC power supply. • Two DC power cables to connect the radio-modem assembly and the power amplifier module to the DC power supply.  • Coax cable (24 inch) to connect the Exciter module to the power amplifier. Frequently, Paragon4 product components are field-assembled prior to customer delivery.  The cabinetry may then be supplied in one of several custom rack-mount configurations that may also in-clude fan, backhaul modems, duplexer/filters/combiners, and ancillary equipment.  If damage has occurred to the equipment during shipment, file a claim with the carrier immediately. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   54. Installation Figure 1 - Front view "Radio Assembly" 4.1 Overview The cabinet and rack-mount housing the Paragon4’s radio-modem and Power Amplifier is generally installed in a sheltered facility. Occasionally located adjacent to the nerve center of the user’s network, it is often located near tower sites or at remote locations where it operates unattended. Furnishings needed include power, cabling, and installation of antenna, landline or microwave mod-em, and host PC or portable computer. Details of these are outside the scope of this manual. This ma-nual covers the radio-modem assembly. The power amplifier has its own user manual that is incorpo-rated by reference at the moment of the order. 4.2 Location Be sure to place the Paragon4 unit in such a way that: • The LEDs can be seen (as an aid in troubleshooting) • Access to the antenna connector and to the back connectors is possible without removing the unit  • Sufficient air may flow around the unit to provide adequate cooling.         Figure 2 - Typical rackmount installation of radio modem and Crescend PA   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   64.3 Rear Views Figure 3 - Paragon4 unit rear view  Figure 4 - Backplane    RX1 RX2BSC2ExciterSpeaker Panel       .      10-amp fuse  J18Access  port J9J19Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   7 Table 2 - Test Points Backplane Test Points Rx/Tx Test   J9 Access port  Alternate Pinout Ground  GND   Pin 14  J18, J19 – Pin 3 SINAD & Distortion  RX1 -Differential  1P-Pin3; 1N-Pin8  J18- Pins 1,2 SINAD & Distortion  RX2-Differential  2P-Pin4; 2N-Pin9  J19 – Pins 1,2 RSSI  RSSI 1 -Differential  1P-Pin1; 1N-Pin6  J18 – Pins 4,5 RSSI  RSSI 2-Differential  2P-Pin2; 2N-Pin7  J19 – Pins 4,5 TX Audio  TXAP-Differential (+ve side only)  1P-Pin 5   Key Transmitter  /TXKEY-single ended  Pin 15     4.4 Electrical Configurations Standard 120 VAC electrical power is required. It should be capable of providing at least 10A to power Paragon3 unit (<6A) and ancillary equipment.  4.4.1  Standard Power Supply Configurations The standard configuration for supplying the required +13.8 VDC to the Paragon4 base station and the Crescend Power Amplifier is shown in the two figures below, a simple block diagram and a virtual rack-mount installation. The base station and the power amplifier module receive 13.8 VDC power inputs from the ICT22012-70N power supply module powered at 120 VAC. Figure 5 – Simple AC-to-DC power supply configurations: Block Diagram     120 VAC    AC/DC  Power Supply ICT22012-70N (34 Amp DC Continuous)   PA  CrescendParagon4 Base StationPreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   8  Figure 6 – Simple AC-to-DC power supply configurations: Virtual rack-mount installation  Normally used at room ambient temperatures, the ICT22012-70N can operate within its specifications over a range of -30 to +52 °C. Although it is a high efficiency switched mode power supply, a considera-ble amount of heat is generated during normal operation. While in use, ensure that an adequate flow of cooling air is able to circulate around the power supply, and that the air intake vents on the sides of the unit are not inadvertently covered. Caution: Do not operate this unit in a completely enclosed cabinet.  4.4.2  ICT22012-70N DC Power Supply The rack-mounted ICT 22012-70N power system components used consist of a backplane and two (-70 model) modules. Each provides 450 watts of continuous DC power. The system is designed with active sharing technology to distribute the load current among the modules. Each module is equipped with a high power Schottky OR-ing diode for true redundancy. If a module failure occurs, the other module(s) will continue to supply power. Each unit is protected in several ways: • Fuse against over current on the AC input. • Current Limit and Foldback – Prevents the load from drawing current above the maximum al-lowed value. • Sudden energy surges on each module – Thermistor against inrush current. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   9Prior to powering up, ensure that both voltage selection switches (located on the back) are set to the proper voltage for your operation. Available settings are 120 or 220 volts.  The ICT 22012-70N metal enclosure is internally connected to earth ground via its individual, rear-connected, 120VAC (NEMA 5-15p plug to IEC 60320-C19 receptacle) power cord. Therefore, the system must be operated from an out-let with a proper grounding connection. Cautions: It is important that the side ventilation holes are unobstructed at all times. Do not oper-ate this unit in a completely enclosed cabinet. High current leakage, use only the cord supplied with this equipment for power. If accessing modules, power at both the switch and the AC inlet must be disconnected to ensure operator safety. 4.4.2.1 Fuse Replacement To access the fuses, the ICT unit cover must be removed. Ensure that power (cable, battery or solar source) is removed. Remove eight side screws and washers (Figure 7). Slide the cover off. Referring to the illustrations in Figure 8, locate the two 32V 35A fuses and replace as needed. Once completed, reverse the above steps to re-install cover. Only finger tighten the eight screws.    Figure 7 - Screw removal detail  Caution: To protect against fire or electrical shock, replace with only the same type and ratings of fuse. Figure 8 - Fuses Location  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   10 4.4.2.2  Power Supply Connections and Torque Settings  Warning: Securing the DC Power Supply cable into the DC connector to provide a good electrical connec-tion is essential. Over time, the wires tend to compress in the DC connector resulting in an in-creasingly poorer connection. Consequently, as high current is drawn, the connector heats up increasing the resistance thereby causing still more heat until the connector eventually burns up.  Although screws securing DC cables to the Power Supply terminals are tightened to the torque set-tings given below prior to new system delivery, they must be re-tightened as part of the commission-ing process and re-tightening is also part of the regular maintenance schedule. Prior to replacing a Power Supply module into an existing system, inspect the cable and re-terminate the wires if the strands have previously been twisted together or show any sign of damage. Cut the wire at the end of the insulation and then strip approximately 11mm (.43 inch) of insulation off the cable. DO NOT TWIST THE WIRE STRANDS. Insert the cable into the screw terminal and tighten the screw to secure the cable as per the torque settings given below. Torque Settings: The manufacturer recommends torque setting all power supply terminal screws to a minimum of: • For the ICT 22012-70N  Power Supply; 35 in-lb Note: CalAmp-Dataradio uses a Sturtevant Richmont 29-piece adjustable torque screwdriver model CAL36/4K. After tightening, pull on the cable to check the cable is secured tightly into the screw terminal.  4.4.3 Crescend Power Amplifier The Crescend power amplifier receives its +13.8VDC power from the ICT DC power supply through a 10AWG DC power cable.  In the standard configuration shown in Figure 3, there is no in-line fuse be-tween the power supply and power amplifier, all the short-cct and foldback protection is done by the ICT power supply. In this configuration, the voltage drop through the power cable is minimize. Nonetheless, if required a DC power cable with an in-line fuse can be ordered from the factory. The power amplifier is maintenance free, only LED indications are present on the front panel. The loca-tion of the DC power terminal block, the “RF In” as well as the “RF Out” N-type female connectors are all on the back side of the power amplifier module. For the 700 and 800MHz models, the power output is normally set to 70W and for the UHF model, it is set to 100W (or lower depending on the work order) at time of manufacture or via RMA. However, to allow for field adjustment of the output power to meet the ERP granted by the transmission site license, a potentiometer is accessible via a small round opening on the underside of the power amplifier. Adjust us-ing a small tuning screwdriver. CalAmp does not recommend adjusting below 35 watts for the 700 and 800MHz models and 50W for the UHF model.  As per Industry Canada Radio Standard Specification #131, paragraph 5.3: “For the 700 and 800MHz models, the amplifier module delivers 70W with 28dB gain at 100mW input over a large nominal bandwidth (500-1000MHz) designed platform.  For the UHF model,  the amplifier module delivers 100W with 30dB gain at 100mW input over a large nominal band-width (200-800MHz) designed platform The manufacturer's rated output power and power toler-ance of this equipment is for single carrier operation in the specified frequency range. It should not be used for multiple carrier operations or outside its specified range.” Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   11Although a rear-mounted fan brings in air from the back and blows it across the heatsink fins, a consider-able amount of heat is generated during normal operation. The amplifier must have a minimum of 3 inch-es of open space behind the rear fan to allow adequate ventilation. The air inlets and outlets should be checked every 30 days and cleaned if necessary. If dust and dirt are allowed to accumulate, the cooling efficiency will be diminished. Using either compressed air or a brush with soft bristles, loosen and re-move accumulated dust and dirt from the air inlet panels. Caution:  Do not operate this unit in a completely enclosed cabinet. Crescend Terminal Block Torque Settings:  Although the manufacturer does not specify definite torque settings for its terminal block screws, the fol-lowing values can be used: • 8 In-lb (9 maximum).  4.4.4  Paragon4 Power and Ground Connections 4.4.4.1  Power Connections  The Paragon4 base station’s modem-controller, radio (dual-RX & TX) and speaker panel modules receive their +13.8VDC power via the backplane PCB. A 12AWG DC power cable provides power to the back-plane PCB at the heavy duty power connector J20.     4.4.4.2  Ground Connections  The Paragon4 base station chassis requires a secure ground connection. A grounding 8-32 threaded throughole pemstud  fitted with a 8-32 screw, lockwasher and nut is provided on the bottom- rear of the chassis, behind the speaker panel.  • Install a 3-4ft 10AWG grounding wire, crimped on both sides with terminal rings. Place one side over the 8-32 screw on the non-exposed chassis side and firmly tighten with the lockwasher and nut.  • Place the other side on the rear side the power supply metal case, near the 25-pin connector. Use a ½ in 4-40 screw with lockwasher to secure the terminal ring to the metal case.  • If a –DC rail (0V) is installed as part of the system, the grounding lead may alternatively be fitted to the rail terminal. Caution: Improper grounding between power supply case and rack frame may result in harmful voltage poten-tials and/or miscellaneous power supply switching noise problems in both receivers and transmitter. 4.4.5 Backplane Fuses Blade fuses (Maxi-Fuse) are used on the Radio assembly backplane:  Fuse Type  Dimensions – Inch (mm) A B C Maxi-Fuse  1.15 (29.21)  1.35 (34.29)  .35 (8.89)  Fuse #  F1 Values 10A   Figure 9 - Maxi-Fuse    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   124.5 Antenna 4.5.1 Overview The Paragon4 unit commonly uses three antennas (one transmit and two receive) unless a duplexer is used with one of the receive antennas; then only two antennas would be needed. If the 10MHz Dis-ciplined Clock option is sought, there is another GPS antenna in addition to the three already men-tioned. They should be mounted according to any guidelines supplied with the antennas. For antennas placement and spacing, consult System Engineering.  4.5.2  Cabling and Connection 1- Route good quality 50-ohm double-shielded coaxial cable(s) (e.g. RG-214 or Heliax) from the se-lected antenna position(s) to the Paragon4 Radio assembly. 2- Referring to Figure 3 for locating modules, terminate the RX-1 and RX-2 cable-ends at their re-spective module rear position with N-type connectors. 3- Similarly, terminate the TX cable-end at the rear position of the Power Amp’s module with an N-type connector. Caution:  When terminating RF cables use brand-name crimping tools (such as AMP, Jensen, Crimp-Master, etc…) of the correct size for the cable and type of connector used. Common pliers are NOT acceptable. 4.6  Completing the physical Installation Paragon4 products are factory-configured to user’s requirements and are shipped ready to run.  After new installations: • Re-check that all connections are secure on the radio-modem assemblies (antennas, PC, power cords etc.) • Check that fuses are inserted. • Turn power supply ON. You are now ready to check for normal operation (as per paragraph 4.7) and to run the Dataradio web interface (described in section 6) for testing or trouble-shooting.   4.7  Checking out Normal Operation 1- Check that power is applied. 2- Check Radio assembly lights for proper operation as per section 5.1 3- Check for proper operation of the BSC2 LEDs. 4- Using the web interface program and an in-line wattmeter, check forward & reverse power to confirm main antenna installation. 5- Using the web interface, check the RF Data Link with a mobile that can be heard. If user application and mobiles are available, test the installation by going through a normal sequence of transmitting and receiving messages.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   13 LOCK  PWR RCVR GATELEVELVOLUME NORM - DiversitySDR Rx 5. Operating Description 5.1 Radio Assembly The Radio assembly component of each Paragon4 product – UHF, 700 or 800 MHz – is made up of a high performance synthesized radio base station designed for single channel operation. The Radio Assembly’s modules are commonly installed in a standard, 19-inch wide rack frame.  The complement of modules is: • 1 x Receiver module • 1 x Exciter module • 1 x BSC2 (controller-modem) • 1 x 70 or 100-Watt Power Amplifier 19” rack-mount assembly  • 1 x Power Supplies • 1 x Speaker panel  For locating each module, refer to Figure 3 above.  5.1.1 Receiver module The receiver has several front panel controls and indicators. These are: • Four LEDs:  PWR LED Green   normal operation Amber   bootloader program running Red   malfunction / reset LOCK LED Green   PLL locked Red        PLL not locked 1 LED Green   RF carrier signal on audio channel 1 is above ma-nually adjusted mute threshold Off   RF carrier signal on audio channel 1 is below ma-nually adjusted mute threshold 2 LED Green   RF carrier signal on audio channel 2 is above ma-nually adjusted mute threshold Off   RF carrier signal on audio channel 2 is below ma-nually adjusted mute threshold  • RCVR GATE LEVEL  - Mute threshold adjustment. It sets the RF signal level required to open the mute gate and allow audio to pass to the speak-er. • 1 / 2 Switch – Manual selection of Channel 1 or 2 audio  • Volume - The audio output delivers up to 1 watt to the speaker. Always set volume knob to min-imum when not in use to reduce current consumption. • NORM-MON Switch – Manual selection between MONitor: audio unmuted (continuous audio monitoring) and NORMal: audio unmuted only when above the manually adjusted mute threshold level • one DE-9 RS-232 ports for setup  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   145.1.2 Exciter module The Exciter’s front panel controls and indicators are: • LED indicators, according to the table below. *The cause of Fault or Warning conditions will be displayed on the Unit Status web page and recorded in the MaintenanceÆSystem Log.    • Carrier test - momentarily keys the transmitter ON while pressed (used for test purposes only). If the Carrier is pressed for 4 seconds or more the exciter starts the test mode and keeps transmitting until the next press of the button. • One DE-9 RS-232 ports for setup.                    5.1.3  BSC2  Module The BSC2's front panel connectors and indicators are:                 Green Red  Flashing Amber Off Power  Normal  Fault *  Warning *   TX  Idle (un-keyed) Normal Mode: Transmitting in normal mode Test Mode:  transmitting in test mode Idle 10 MHz  10 MHz Locked 10 MHz con-nection bro-ken, unable to lock Acquiring 10 MHz Lock Idle if 10 MHz was never con-nected. Lock  Synth lock, Normal Synth unlock Fault  Programming mode  PWR LED Green   Normal operation Red   Bootstrap step 1 – lights for <5 sec. Amber  Bootstrap step 2  – lights for <5 sec. Red flashing  Hardware error, check Unit Status web page RX LED  Green   Flashes for each data packets received Red       Discard RX packet (factory-use) TX LED Green   Flashes for each data packet transmitted Amber Flashes for each data packet transmitted  (check for lost Host connection on Unit Stat web page) Red Continuously ON during TXON test (max. 20 sec) Flashes during CWID key-down Off   When AirLink down selected by PF rocker switch STATUS Green   Flashes each time PF1 or PF2 is pressed Amber Flashes each second PF1 is kept pressed  Toggles “AirLink down mode” after 4 seconds LOCKPWR TXExt. 10MHzCOM Carrier Test SDRExciterPreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   15  • 2x DE-9 RS-232 ports for setup and user data • 1x rocker switch (positions PF 1 and 2) to select various test modes. See paragraph 5.3.2.  • 2x Ethernet ports – for setup and user data • 2x Ethernet LEDs (status & activity)  • USB port – reserved.  5.1.4 Power Amplifier Model using Crescend Technologies power amplifier (Illustrations not drawn to scale). The location and function of the power amplifier's front panel status indicators are shown in Figure xx and described in the table below:   Table 3 - Power Amplifier indicators      LED Function DC ON  Lights green when DC power (+13.8 VDC) is applied LOW OUTPUT  Lights red when output power drops to approximately 80-85% of set output power HIGH VSWR  Lights red when VSWR exceeds approximately 2.5:1. At which point, the amplifier output is reduced. The higher the load VSWR, the more the output power is reduced. HIGH TEMP Lights red when the amplifier exceeds a safe operating temperature (Operating temperature range = -30 °C to +60 °C) When the heatsink reaches an unsafe level, the output power of the amplifier is re-duced by approximately 50%. This keeps the channel on-air while providing some short-term protection. Address the underlying cooling issue as soon as possible. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   16 SpeakerPanel 5.1.5 Power Supply  The power supply modules are manufactured by ICT (Innovative Circuit Technology Ltd).  LED indicators are provided as standard feature. They provide module information as shown in Table 4. Table 4 - ICT N+1LED Module Status Display GREEN  YELLOW AC line voltage is present  Module is not present in the slot DC output voltage is present  Module is not producing any output Module voltage is present    For more information on these power supply modules please refer to ICT N+1 Redundant Power Supply Instruction Manual from ICT.  5.1.6 Speaker Module The speaker panel is fitted with an 8Ω speaker.                        Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   175.1.7  Hardware Options    5.1.7.1 GPS Receiver  Systems configured for Tower Steering or Disciplined Clock (see below) require the installation of the GPS receiver board inside the BSC2 module.  With this option installed, there will be a GPS antenna SMA connector at the rear of the BSC2 module (see Figure 3.).  5.1.7.2 Disciplined Clock  For 700MHz Narrowband operation only, the FCC or other regulatory bodies impose strict limits on the frequency error of transmissions.  Dataradio SDR radio modules minimize frequency error through the use of a 10MHz reference clock.  This clock can come from one of two sources: -From an external 10MHz reference, supplied by the customer. It connects to the BNC1 connector on the P4 backplane PCB and with jumper JP1 set to position 2-3.  -From a Disciplined Clock board inside the BSC2 module. Only one of the above options can be selected and the hardware to support the option must be installed by the factory. The Disciplined Clock option also requires that the GPS Receiver option be installed.  The Disciplined Clock uses the 1PPS (One Pulse per Second) output of the GPS receiver to produce the 10MHz reference clock.  When 1PPS is being supplied, the reference clock has accuracy better than 1ppb (+/- 0.010 Hz at 10MHz).  When 1PPS is unavailable, accuracy can fall to 5ppm (+/- 50Hz at 10MHz).  In this situation, the Paragon4 can be configured to gracefully go off-the-air causing mobiles to roam to other base sta-tions.    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   186. Operation & Configuration Instructions and examples given in this manual are based on E-DBA operating software version current at the time of writing this document and may not apply to earlier or later software versions. Screen captures used throughout this document may vary from actual screens. 6.1 Browser-Based Interface A built-in web server makes configuration and status monitoring possible from any browser-equipped computer, either locally or remotely. Status, configuration, and online help are available without requiring special client software. Setup is password-protected to avoid tampering or unauthorized changes.  Both the configuration parameters and operating firmware can be updated remotely, even over the RF network itself, using the standard File Transfer Protocol (FTP). Figure 10 - Web Interface 6.1.1  Interface Setup and Status The Paragon4 user interface is used to view and configure your network settings. Figure 10 shows the welcome screen of the Web Interface. The screen is subdivided in two frames: the frame on the left al-lows the user to navigate through the menus, while the main frame on the right displays the selected page. The menu system is two-leveled; some of the top-level menus expand to offer submenus. The Site Map link can be found right below the menus on the navigator pane. Help is available for each page displayed in the main frame. It can be accessed at all times by clicking the Help icon. The remaining buttons on the bottom of the Navigator frame are used to save your configurations and reset the unit.      Navigator Frame Main Frame Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   196.3  IP Network Configuration Paragon4 base stations feature two Ethernet interfaces (ETH1 and ETH2) and one RF interface. ETH1 is commonly connected over the backhaul to the Host network. ETH2 is commonly used for a local connec-tion for setup purposes. 6.3.1 Default IP Settings Paragon4 radio modem supports the Router (IP Forwarding) mode 6.3.1.1 ETH1 • MAC:     00:0A:99:XX:YY:ZZ • IP ADDR:     192.168.202.1 • NETMASKS:   255.255.255.0 • Default Gateway:   0.0.0.0 • DHCP Client  Disabled • RIPv2   Disabled 6.3.1.2 ETH2 • MAC:     00:0A:99:XX:YY:ZZ + 1 • IP ADDR:     192.168.203.1 • NETMASKS:   255.255.255.0 • DHCP Server  Disabled • NAT   Disabled 6.3.1.3 RF Interface • MAC:     00:XX:YY:ZZ • IP ADDR:     10.XX:YY:ZZ • NETMASK:   255.0.0.0 • Encryption   Disabled Keep the RF IP setting as is, providing customer is not using the 10.0.0.0 IP network. Enable RIPv2 on Base station.  6.3.2  Configuring Local PC 1. ClickStartÎSettingsÎControlPanelÎNetworkandDial‐upConnection2. ClickontherelevantLocalAreaConnection3. OntheLocalAreaConnectionStatusscreen,clickProperties4. OntheLocalAreaConnectionPropertiesscreen,scrolltheListBoxuntil“InternetProtocol(TCP/IP)”ishighlighted,clickProperties5. OntheInternetProtocol(TCP/IP)Propertiesscreen,followeithermethodbelow:6. IfusingETH2(SetupLAN),select“ObtainanIPaddressautomatically”7. Select“UsethefollowingIPaddress”ÎEnter192.168.202.2(ifETH2enter192.168.203.2)intheIPaddressfieldÎ255.255.255.0intheSubnetmaskÎLeavetheDefaultgatewayblank.8. ClicktheOKbutton9. StepsabovespecificallyapplytoMS‐Windows2000.ModifyasnecessaryfortheOSyouarerun‐ning  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   206.3.3  IP Network Settings (Paragon4 connected directly to Host) Figure 11 below illustrates Paragon4 base station settings. In Setup (Advanced) Î LAN (IP), set ETH1 and ETH2 IP addresses and netmask of both Base and Mobile(s). Keep the RF IP setting as is, providing customer is not using the 10.0.0.0 IP network. Add routes in the Host to reach the RF Network (route add…) In the illustration, Host and PC are part of different IP subnet Figure 11 - IP Network Settings in Router Mode (with Host) 6.3.4  IP Network Settings (Paragon4 connection to Router) Figure 12 below illustrates Paragon4 base station settings. In Setup (Advanced) Î LAN (IP), set the ETH1 and ETH2 IP addresses and netmask of both Base and Mobile(s). In the illustration, Host and PC are part of different IP subnet. Figure 12 - IP Network Settings in Router Mode (with Router) On a PC running MS-Windows with an existing LAN connection, connect either to the ETH1 or to ETH2 RJ-45 input of the Paragon4 base station.  Paragon4 Base   SETUP:  Eth2 IP: 192.168.203.1 MASK: 255.255.255.0    RF IP: 10.0.0.1 MASK: 255.0.0.0 Mobile DHCP Server   RF IP: 10.0.0.2 MASK: 255.0.0.0   Eth1 IP: 192.168.201.1MASK: 255.255.255.0 RF Network Host IP: 192.168.202.2 MASK: 255.255.255.0       route add 10.0.0.0 mask 255.0.0.0 192.168.202.1  PC DHCP Client  DATA: Eth1 IP: 192.168.202.1 MASK: 255.255.255.0 Paragon4 Base SETUP:  Eth2 IP: 192.168.203.1 MASK: 255.255.255.0         RF IP: 10.0.0.1 MASK: 255.0.0.0 Mobile DHCP Server NAT    RF IP: 10.0.0.2 MASK: 255.0.0.0    Eth1 IP: 192.168.201.1MASK: 255.255.255.0 RF NetworkRouter IP: 192.168.202.2 MASK: 255.255.255.0 route add 10.0.0.0 mask 255.0.0.0 192.168.202.1 PC DHCP Client  DATA: Eth1 IP: 192.168.202.1 MASK: 255.255.255.0 Default Gateway: 192.168.202.2 HostPreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   21 6.4  Web Server Login  In an Internet browser, enter http://92.168.20x.1 (where x is 2 for the ETH1 Data port and 3 for the ETH2 Setup port). This will bring up the Paragon4  product login page (Note:  It may take 30 seconds from ini-tial power-up for the homepage to be available.)  Login to the device. For an initial installation, enter a User Name of 1 to 15 characters and the default Password ADMINISTRATOR (upper case letters). Click OK. The web interface “Welcome” screen opens (Figure 13). For subsequent access to the Paragon4 unit, use the User Name and Password that you will have confi-gured (as detailed in section 6.9.1).  Notes: User Name field can be left blank. It only serves to identify the person gaining ace ss.  Password is common and affects all User Name entries. Figure 13 - Web User Interface – Welcome Screen  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   226.5 Web Interface The Paragon4 user interface (Figure 13) is used to view and configure your network settings.  To navigate, use the top-level menus on the left, some of which expand to offer submenus, and display the first submenu in the right-hand frame. Click the current submenu entry to refresh the right-hand frame. The tables starting at section 6.6.1 below list action of each function. The interface main screen lists available selections for the selected menu or presents instructions. Notes:  At any time, click the Help icon in the navigation pane to open a help text relating to the window being displayed. 6.5.1  Apply, Cancel, Save Config, and Reset Unit Buttons & Help Icon  Several submenus have “Apply” and “Cancel” buttons.  The navigation area has “Save Config”, “Reset Unit” but-tons and a Help icon.  If you “Apply” changes to any parameters marked  you will need to do a “Save Config” and a “Re-set Unit”. When making an entry into a dialog box, click on Apply when satisfied to temporarily apply the value(s) entered to the relevant parameter(s). If not satisfied, click on Cancel button to restore to the value(s) present before a change was made. Note: Cancel command only affects the dialog boxes or option buttons in the opened window. If needed, go to other submenu(s) and make more entries. Click Apply before leaving each window. When finished, click the Save Config button to make all changed entries permanent.  Notes: “Apply” writes to RAM, thus failure to use the “Apply” command button before leaving a web page will result in the loss of temporarily entered selections, addresses, and values. “Save Config” writes in flash, thus failure to use the “Save Config” command button will result in the loss of temporarily entered parameters. A “Reset” is required to make flash changes take effect. Click on Save Config button:  • If there are changes to be saved, saving occurs right away • If there are no changes to be saved, a pop-up window prompts user to confirm saving anyway Click on “Reset Unit” button:  • If there are changes to be saved, a window prompts user to confirm resetting. • If there are no changes to be saved, resetting occurs  right away A “Station Reset” 20-second timer counts down while the status reports: “Working…” When done, the status reports: “Ready”.      Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   23 6.6  Unit Status  6.6.1 Unit Status ► General Displays values that identify the unit and show its basic operating condition.  Figure 14 - Unit Identification and Status Item  Description Banner  Displays Paragon4 software revision information retrieved from the connected unit. Have this information handy if contacting Dataradio support. Station Name  Displays name of connected unit.  Configured under Setup Basic Î General Î Station Name  System ID  Displays System’s unique identification number Configured under Setup Basic Î General Î System ID Local Time  24-hour clock format display of the GMT time and date adjusted to the specified time zone.  Configured under Setup Advanced Î Time Source Î SNTP CWID Callsign Continuous wave ID - Way of sending FCC license ID using Morse code. Continuous Wave Identification uses Morse Code to automatically send out the station ID periodically to identify the owner of the transmitting base station. This satisfies the require-ments of the FCC. CWID Interval   Interval between CWID messages in minutes.  Zero = never. Unit Status Normally displays “Ok” in the message area.  Displays various warnings or messages in the event of hardware failure,  If indications persist, have the status information handy if contacting Dataradio support. Host Status Status of the link to the specified Host, if configured in Setup (Advanced) → Roaming → Host Link Active. Values displayed are Disabled, Reachable, and Unreachable. Acknowledge Unit Status  Press this button to clear the Unit Status message area.   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   246.6.2 Unit Status ►Radio Info & Status Radio Information read-only table displays the Paragon4 radio information retrieved from the connected radio modules. Have this information handy if contacting CalAmp. Paragon4 models that have both re-ceivers combined into a single module will show the same information in the RX main and RX diversity rows.  Figure 15 - Unit Status - Radio Information Item  Description Radio Info Radio Device  Identifies the installed radio module’s model Status  Identifies the status of the active radio (Ok or Fault –module is down) Model Number  Indicates the model of the receiver/transmitter Serial Number  Unique number assigned to the receiver/transmitter at time of manufacture Frequency range  Shows the receive/transmit frequency range the unit can synthesize.  For information on the frequency ranges for each radio model, see Section 8, Specifications. Firmware  Identifies the version number of the firmware installed on the receiver/transmitter Hardware   Identifies the version number of the hardware installed  (receiver/transmitter) CPLD Version  Identifies the version number of the CPLD (Complex Programmable Logic Device) Unit Assembly Num-ber  Identifies Unit Assembly Number  Current Radio Settings RX Frequency  Shows the current (or last) receive frequency TX Frequency  Shows the current (or last) transmit frequency  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   25Channel Type  Shows the current (or last) channel type Detailed Radio Status System  10 MHz Standard - 10 MHz reference- Active (10 MHz signal present) or Inactive (10 MHz signal not present or not within specification) Disciplined Clock Status Internal 10 MHz reference status Locked =   The Disciplined Clock has acquired GPS lock and is providing a valid   10MHz source. Unlocked =   The Disciplined Clock has lost its GPS lock and is waiting for GPS     signal reacquisition. The 10 MHz source is still valid.  Never been locked yet =  After power up, the Disciplined Clock has not acquired its first GPS     lock yet. The 10 MHz source is not valid. Fault =    The Disciplined Clock cannot provide a valid 10 MHz source for one     of the following reasons:        1. There was a hardware or firmware initialization error.        2. The GPS has failed to acquire any satellite signal within            the allowed time period (Check GPS antenna) 10 MHz source unreliable =   The Disciplined Clock has lost its GPS lock for too long and cannot     guaranty the accuracy of its 10MHz source anymore (check GPS      antenna). This message can also appear if the VCO on the Disci     plined Clock circuit is no longer within specification due to age,      damage or extreme environmental conditions.  Disabled =   The Disciplined Clock is not active. The 10MHz source from this cir    cuit is unreliable or an external source is provided.  Disciplined Clock Temperature Displays Disciplined Clock temperature in degrees Celsius.  Note: Displays "N/A" if the Disciplined Clock's state is "Disabled".  Receiver Detailed Status Temperature  Receiver's temperature in degrees Celsius.  External 10 MHz de-tected  Yes (10 MHz signal in use by the receiver), No (10 MHz signal not in use by the receiver) Using External 10 MHz  Yes, No (10 MHz signal is in use by the receiver) PLL Locked  Yes, No (RF synthesizer is phase-locked-loop to internal 17.5MHz or external 10MHz reference signal.) Exciter Detailed Status Temperature  Exciter's temperature in degrees Celsius Transmit in progress  Yes, No  10 MHz Standard in use  Yes (10 MHz signal in use by the exciter), No (10 MHz signal not in use by the exciter) 10 MHz Standard Error Yes, No (The exciter will report a failure when the 10 MHz signal is present initially and removed after system initialization.) RF Synthesizer Locked Yes, No (May signify RF synthesizer device error. Contact support for additional infor-mation.) MOD Synthesizer Locked Yes, No (May signify MOD synthesizer device error. Contact support for additional in-formation.)   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   266.6.3 Unit Status ►Diagnostics Figure 16 - Unit Status – Diagnostics  Item  Description Analog Values Chassis power supply  Displays chassis power supply voltage Power amplifier pow-er supply Displays power amplifier power supply voltage. Available only if extra wires are added from the PA +/- supply terminals and the P4 backplane TB1-1 / TB1-2 terminals. Forward power  Displays forward power when the optional external power sensor assembly (p/n 030-03547-xxx) is installed. Note: Power measurement units (dBm or Watts) are user defined under Setup Advanced ►User Settings Reverse power  Displays reverse power when the optional external power sensor assembly (p/n 030-03547-xxx) is installed. Note: Power measurement units (dBm or Watts) are user defined under Setup Advanced ►User Settings  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   27Standing Wave Ratio Displays Standing Wave Ratio. Standing Wave Ratio (SWR) is computed as follows:  Note: SWR is always computed-based on the forward and reverse power values in Watt, regardless of the power measurement unit chosen for display. Chassis temperature Displays the internal unit chassis temperature. That temperature is usually 10 to 15oC higher than ambient room temperature.      Default range: 15 to 40oC Note: Temperature measurement units are user defined under Setup Advanced ►User Settings Analog monitoring 1  Generic Analog input (0 – 30VDC) Displays user supplied analog input’s measurement values  Analog monitoring 2  Generic Analog input (0 – 30VDC) Displays user supplied analog input’s measurement values Fan 1  Fan speed monitoring signal.  Analog sinusoidal input (0-5VDC)  or digital TTL input (de-tection threshold, low = 0.4V max and high = 2.4V min). Fan 2   Fan speed monitoring signal.  Analog sinusoidal input (0-5VDC)  or digital TTL input (de-tection threshold, low = 0.4V max and high = 2.4V min). Digital Values Alarm A1 input  Generic Alarm inputs. Programmable active high or low polarity. Safe voltage range -0.1V to 30V.  When active high (low):  Voltage guaranteed to be detected as an alarm: 2.4V min (0.4V max). Voltage guaranteed not to be detected as an alarm: 0.4V max (2.4V min). Alarm A2 input  Alarm B1 input  Alarm B2 input  Status For all digital and analog alarms displays alarm status: Normal or Fault. For Forward Power and Standing Wave Ratio (SWR) displays “Transmitter off” when the transmitter is off. Disregard the diagnostic value for SWR, Forward Power, and Reverse Power if the transmitter is off. Range Displays range of values for all monitored analog diagnostic parameters.  User-configurable under Setup (Advanced) ►Diagnostics. Recommended nominal ranges are: Chassis Power Supply  10.8-16.0 Volts Power Amplifier Power Supply  13.1-14.5 Volts (with Crescend PA) Forward Power (700 & 800 MHz)  15. 0-77.0 Watts Forward Power (UHF)  15. 0-110.0 Watts  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   286.6.3.1.1  External Analog/Digital Inputs Monitoring   The user can connect and monitor two external analog and four external digital inputs to the backplane TB1 connector terminals ( Figure 17 and Figure 18).     Figure 17 - Backplane -TB1 connector  Figure 18 - TB1 connector  An external analog device’s voltage must not exceed 30 Volts. The default units of measure used for monitoring an external device are volts. It is possible to change the default units by creating a look-up table for the desired unit of measure. This look-up table is created following the guidelines in section 6.8.10.1 and is uploaded into the Paragon4 unit using FTP transfer.  Refer to section 6.8.10    TB1 Analog monitoring 2   Analog monitoring 1   Alarm B2 input Alarm B1 input Alarm A2 input Alarm A1 input Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   29  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   30Note 1: TB1 connector labeling differs from the actual backplane:  TB1 / Web page name(s)  TB1 / Backplane name Power amplifier power supply +13V8_PA Alarm A1 input  AL_A1 Alarm A2 input  AL_A2 Alarm B1 input  AL_B1 Alarm B2 input  AL_B2 Analog monitoring 1  AN1 Analog monitoring 2  AN2  6.7 Setup (Basic) 6.7.1 Setup (Basic) ► General Used to set four basic operating fields on the connected unit. Figure 19 - Setup (Basic) – General Setup Item  Description Station Name  Station name identifier – Enter string up to forty characters in length (letters and/or numbers) System ID Factory default ID is zero. To prevent collision and to minimize interference from re-mote systems that may be present on the same frequency, Dataradio recommends changing the System ID to some other value unique to each network.  Upper limit is 255 CWID Call sign  Historically called “Continuous wave ID” – Way of sending FCC license ID using Morse code CWID Interval  Interval between CWID messages in minutes Zero = never.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   316.7.2 Setup (Basic) ► IP (Basic IP Configuration) Sets the IP characteristics of the primary, or only, Ethernet port (ETH1). Figure 20 - Setup (Basic) – Basic IP Configuration  Item  Description Use fixed IP settings  Creates a fixed TCP/IP address connection. You may need to ask your network adminis-trator for the appropriate IP settings. IP Address Set to valid unique IP address for each individual unit.  Factory default is 192.168.202.1 for all Paragon4 units connected to their ETH1 port. For ETH2 configuration, see Setup Advanced Î LAN IP   Netmask  Set to valid IP netmask for each individual unit (may be same or different depending on customer’s IP network topology). Default Gateway  Set to valid Default Gateway.  May change for different groups or locations Use DHCP Client  Dynamic Host Configuration - Dynamically assigns an IP address IP Address Netmask Default Gateway These three read-only fields display the IP addresses obtained from the DHCP Server For ETH2 configuration, see Setup Advanced Î LAN IP    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   326.7.3 Setup (Basic) ► RF (Frequencies) Figure 21 - RF (Frequencies)    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   33Item  Description Radio Capabilities RX Frequency Range  Shows the receive frequency range the unit can synthesize Typically: Rx 792 – 824     TX Frequency Range  Shows the transmit frequency range the unit can synthesize Typically: Tx 763 – 776    Channels Table Set Up Active Channel  Select one at a time (from 1 to 32) Status  Displays channels setup status.  OK or Invalid (invalid RX/TX selection or receiver/transmitter is down)  RX (MHz) TX (MHz) Enter RX and TX frequency in MHz in the appropriate dialog box. Note: The RF frequencies entered must match the corresponding RF frequency on the GeminiG3 mobile radios.  Entries must fall within the Min and Max indicated on top of the page (erroneous entries will be highlighted in red) and must be multiples of corresponding frequency step (6.25 KHz for 700/800 MHz frequency ranges or 5, 6.25, or 10 KHz for UHF frequency ranges). Dataradio recommends (in North America) offsetting the TX column frequency by +30 MHz for 700 MHz frequency ranges, by -45 MHz for 800 MHz frequency ranges, or by +/- 5MHz for UHF frequency ranges.  E.g.: Assuming:  Min Rx=851.000 000 MHz  Max Rx=869.000 000 MHz  Offset=-45.000 000 MHz If selection for a channel's RX was:  Rx (MHz)=853.037 500  then its corresponding TX would be computed as:  Tx (MHz)=853.037 500+(-45.000 000)=808.037 500   Note: Exercise caution when entering RF frequencies. Paragon4 base station will reject any entry with a wrong frequency step and will transmit at the previous correct entry or return to its default (factory-configured) RF frequency setting.   Airlink Speed Lists the choice of Airlink speeds, the nominal speed at which data packets are trans-mitted over-the-air in E-DBA. The mobile will automatically adapt to the base station. e.g.: At  800 MHz Full Channel, the choices are: 64kb/s    short messages, medium messages, large messages 48kb/s    short messages, medium messages, large messages 43.2kb/s short messages, medium messages, large messages 32kb/s     short messages, medium messages, large messages Airlink speeds available depend on the channel type selected (from 16 kb/s to 128 kb/s). Note: The channel table settings take effect immediately after Apply is clicked.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   346.7.4 Setup (Basic) ► Serial Ports Setup The Paragon4 base station serial ports can be logically connected to local and remote services to aid in configuration and troubleshooting, or they can be connected to a remote Host application or even to the serial port of a remote unit. Figure 22 - Setup (Basic) – Serial Ports Setup Item  Description Enabled  Independent check boxes to activate COM-1 PORT and/or COM-2 PORT Speed  Select  300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Baud Rate Data Bits  Number of bits making up the data word. Set according to Host configuration. Default is 8. Stop Bits  Number of bits at the end of the data word. Default is 1. Parity  Added to identify the sum of bits as odd or even. Default is None. Flow Control  Select None or CTS-based (depends on connected device) Connection Control  Select Permanent (3-wire) or Switched (DTR bringup/teardown) (RTU dependent) IP Gateway Service Select one of:  CLI Service (Command line interface) RS-232 connection to Host PC (Default = SETUP) Custom – Choosing Custom enables the IP Gateway Transport configuration  IP Gateway Transport  Available only if IP Gateway Service selection is Custom, choose the socket connection mode from the drop-down list box choices of TCP Server, TCP Client, or UDP. Local IP Address  Valid unicast or multicast IP address, including the local Loopback interface address.   Default local IP address is set to 0.0.0.0 and can be changed dynamically without a unit reset. Local IP Port For TCP Client and UDP socket connections, set to any value between 1 and 65535. For TCP Server socket connections, set to any value between 1 and 65535 but must not be set to one of the following values or fall within the following ranges of values: 20, 21, 23, 123, 520, 5002, 6254 to 6299, 7000 to 7100. Otherwise, the parameter configuration will be accepted, but no sock-et connection will be established to accept connection from remote endpoints. Default local port value is set to 1024 and can be changed dynamically without a unit reset. Remote IP Address  Default remote IP address is the Loopback interface address, 127.0.0.1 and can be changed dy-namically without a unit reset Remote IP Port  For socket connection modes (TCP active, UDP), set to any value between 1 and 65535. Default local port value is 23 and can be changed dynamically. Status  Can be UP, READY, or DOWN. Click on the “Refresh” word in the “(Refresh this frame to confirm “Status”) sentence to update Status condition.  10.255.255.25Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   356.8  Setup (Advanced)  6.8.1 Setup (Advanced) ► LAN (IP) Allows the setting of IP characteristics beyond those set in Setup (Basic) Î IP When a mobile registers with a new base, the base may send a message to each of its neighbor to assure that their Internet tables are up-to-date. Up to 32 neighbors can be entered. An empty or incomplete table may cause IP routing problems when the mobile roams. Figure 23 - Advanced IP Configuration - LAN (IP) Item  Description Interface 1 (ETH1) IP Address Netmask Read-only fields showing IP Address and Netmask defined earlier in Setup (Basic)Î Basic IP. MTU Ethernet Interface MTU - Default 1500. –  For optimal performance, set at 1500. Entering a value lower than 1500 may reduce system performance. Flexibility of us-ing lower values may be useful in testing or for particular operational conditions.  Range is 576 to 1500. MAC address  Ethernet Interface MAC address in HEX format (factory-set). Interface 2  (ETH2) IP Address Set to valid unique IP address for each individual unit.  Factory default is 192.168.203.1 for all Paragon4 units connected to their ETH2 port. For ETH1 configuration, see Setup Basic Î Basic IP Configuration   Netmask  Set to valid IP netmask for each individual unit (may be same or different depending on customer’s IP network topology). MTU Ethernet Interface MTU - Default 1500. –  For optimal performance, set at 1500. Entering a value lower than 1500 may reduce system performance. Flexibility of us-ing lower values may be useful in testing or for particular operational conditions.  Range is 576 to 1500. MAC address  Ethernet Interface MAC address in HEX format (factory-set). Neighboring Bases Add  Type in the “Neighboring Bases” field the IP address in dot decimal format of the base to be added to the neighboring “Base List” table. Delete  Type in the “Neighboring Bases” field the IP address in dot decimal format of the base to be deleted from the neighboring “Base List” table. Base List Read-only listing. Dynamic window expands downward as needed to show all ad-dresses added to the list or shrinks as addresses are removed.  Shows “Table is empty” if no address is present in the Base List.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   366.8.2 Setup (Advanced) ► RF (IP) At the time of manufacture, each Paragon4 base station and GeminiG3 radio modem is provided with a unique MAC address for its Ethernet and RF interfaces. These addresses cannot be changed. The RF in-terface is also provided with a unique Factory RF IP address. If this IP address conflicts with any existing IP network, it can be overridden. Figure 24 - Advanced IP Configuration - RF (IP)  Item  Description RF MAC  RF Interface MAC address in HEX format (factory-set). RF IP Address Displays factory-assigned address: nnn.nnn.nnn.nnn “Factory” Entering 0.0.0.0 sets the RF IP Address to the factory default and highlights the “Factory” name (active address) Entering nnn.nnn.nnn.nnn (RF IP Address of your choice) overrides the factory default and highlights the “Override” name (active address) RF Net Mask  Set to valid common IP netmask for all units within a Paragon4 network RF MTU RF Interface MTU - Default 1242. – For optimal performance, set at 1242. Entering a value other than 1242 may reduce system performance, especially if set to a higher value. Flexibility of using other values may be useful in testing or for particular operational conditions.  Range is 576 to 1500.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   376.8.3 Setup (Advanced) ► Roaming The “Host Link Active” feature allows a base to assure the communication backhaul is operating. If not, the base indicates to mobiles on the channel that they should promptly roam to another base The “Base Loaded” feature monitors the amount of network traffic during the previous 10-second period. If there are more than a certain number of mobiles actively sending data and the channel is occupied above a certain percentage, then the base indicates that a portion of the registered mobiles should roam to other bases, until channel loading falls below the thresholds.  Figure 25 - Advanced IP Configuration – Roaming Host Link Active (on ETH1) Link check is…  Disabled (Default), Enabled Host address  IP address of a router/host to be pinged periodically Ping failure threshold  This many failed pings in a row are needed to mark the “Host is…” field as “Unreachable” Ping success threshold  This many successful pings in a row are needed to mark the “Host is…” field as” Reachable” Ping every  How often to send a ping Host is …  Current status of the host link (blank if disabled) Base Loaded Feature is…  Disabled, Enabled Mobile Limit  Minimum number of active mobile before channel can be considered “Loaded” Packet Limit  Minimum percentage of data capacity before channel can be considered “Loaded” Base is…  Current status of the base (blank if disabled) Roaming Mobiles roam if average RSSI is below… Currently registered mobiles will roam if average signal strength of all synchronization pack-ets received in the last 20 seconds is below this value Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   386.8.4 Setup (Advanced) ► IP Services  Figure 26 - Advanced IP Configuration – IP Services Setup  Item  Description Server DHCP Server Disabled, Enabled (Default). The Dynamic Host Configuration Proto-col provides a framework for passing configuration information     e.g.: IP address to Hosts (i.e. PC/RTU) on a TCP/IP network. Gateway Gateway address handed out by the DHCP Server to the DHCP Client. The default value is set to the IP address of the Ethernet 2 interface. If the gateway is set to 0.0.0.0, no gateway address will be handed out by the DHCP Server. Lease Start Address Pool of addresses allocated for DHCP purpose. If a unit is configured as DHCP Server, this field represents the start IP address pool managed by the DHCP Server. Normally, Paragon4 automatically calculates the Lease Start Address (equal to Ethernet IP Address plus one). Lease Duration The period over which the IP Address allocated to a DHCP client is referred to as a “lease”. Lease Duration is the amount entered in minutes. A value of “0” indicates an infinite lease. Maximum number of leases  Maximum number of DHCP client(s) a unit can serve. IPSD IP Services Delivery – Disabled (Default), Enabled. Allows or disallows the generation of locally provided IP Services such as online diagnostics, alarms, etc… NAT (ETH2 only) Network Address Translation - Disabled, Enabled (Default) NAT technology is a method by which IP addresses are mapped from one address space to another. In Paragon4, it is normally used on the WAN side of an IP net-work to hide local IP addresses from an external IP network (i.e. Internet). See section 4.7.3.4.1 for a more detailed description. RIPV2 (ETH1 only) Router Information Protocol v2 - Disabled, Enabled (Default) When Enabled, mobile registration causes RIPv2 report to be sent to the backhaul router(s) so that the infrastructure will route all packets for this mobile through this base station.     Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   39Item  Description SNMP Simple Network Management Protocol – Disabled, Enabled (Default)  SNMP provides means to monitor, collect, and analyze diagnostic information. Enabling SNMP allows the MIB (Management Information Base) in the Paragon4 to be viewed using an external MIB browser or network management software. Trap IP List After reset, the Paragon4 sends a WARMSTART trap to all of the IP addresses defined in the Trap IP list. It signifies that the system has started.  To add an address to the Trap IP List: Select Add and type the new IP address to be added to the read-only Trap IP list. The window will expand downward to show all addresses in the list. To delete an address to the Trap IP List: Select Delete and type the new IP ad-dress to be deleted from the read-only Trap IP list. MIBS Management Information Base -used to assemble and interpret SNMP messages. The Dataradio Paragon4  MIB is bundled with each unit's firmware. Click "Down-load mibs.zip" and a pop-up dialog box will appear in your browser asking you to open or save the file to your PC. Save the zip file to a desired location. Unzip the contents of mibs.zip file to a location where your SNMP manager can find it. Note: SNMP must be enabled in order for the host PC SNMP manager to work.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   406.8.4.1  NAT on the Base Unit (Paragon4) The purpose of the “Network Address Translation” (NAT) protocol is to hide a private IP network from a public network. The mechanism serves both as a firewall function and to save IP address space. When NAT is enabled on the P4, the private network (from the point of view of the Base station) is the IP network associated to the Ethernet 2 interface. Figure 27 - NAT Enabled on Paragon4 Figure 28 - Paragon4 - Example 1 In example 1, Management Host 1 sends Packet (1) to External Host 1. Since the source IP address of Packet (1) comes from the private network, it gets replaced by the IP address of the Ethernet 1 interface of the Base station.  External Host 1200.1.1.1/24 RF Network Public Network (External Network + RF Network + Mobile 1 Network + Mobile 2 Network) Mobile 1 Network Base  (Paragon4)Ethernet 1 192.168.1.1/24Mobile Host 1173.30.1.2/24Mobile (G3)Mobile (G3)Ethernet 2 172.30.1.1/24 RF 10.0.1.2/24  RF 10.0.1.3/24 173.30.1.1/24  174.30.1.1/24 Mobile Host 2 174.30.1.2/24 Mobile 2 Network External NetworkManagement Host 1 172.30.1.2/24 Management Host 2 172.30.1.3/24  Private Network 172.30.1.0/24 RF 10.0.1.1/24 1 Packet (1) Source Address 172.30.1.2 Destination Address 200.1.1.1 2 Packet (1) Source Address 192.168.1.1 Destination Address 200.1.1.1 172.30.1.1/24 192.168.1.1/24Paragon4  (NAT Enabled)  Management Host 1 172.30.1.2/24 External Host 1 200.1.1.1/24Private network (172.30.1.0/24) Public network (External)  3 Packet (2) Source Address 200.1.1.1 Destination Address 192.168.1.1 4 Packet (2) Source Address 200.1.1.1 Destination Address 172.30.1.2 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   41Figure 29 - Paragon4 - Example 2 In example 2, Management Host 1 sends Packet (1) to Mobile Host 1.  Since the source IP address of Packet (1) comes from the private network, it gets replace by the IP address of the RF interface of the Base station. Figure 30 - Paragon4 - Example 3 In example 3, Mobile Host 1 sends Packet (1) to External Host 1.  Since the source IP address of Pack-et (1) does not come from the private network, it doesn’t get replaced by another IP address by the Base station.  2 Packet (1) Source Address 10.0.1.1 Destination Address 173.30.1.2 3 Packet (1) Source Address 10.0.1.1 Destination Address 173.30.1.2 10.0.1.2/24 172.30.1.1/24 Paragon4  (NAT Enabled)  Management Host 1 172.30.1.2/24 Private Network  Mobile 1 Network  4 Packet (2) Source Address 173.30.1.2 Destination Address 10.0.1.1 5 Packet (2) Source Address 173.30.1.2 Destination Address 10.0.1.1 RF Network 6 Packet (2) Source Address 173.30.1.2 Destination Address 172.30.1.2 1 Packet (2) Source Address 172.30.1.2 Destination Address 173.30.1.2 Mobile (G3) (NAT Disabled) 10.0.1.1 /24 173.30.1.1/24  2 Packet (1) Source Address 173.30.1.2 Destination Address 200.1.1.1 3 Packet (1) Source Address 173.30.1.2 Destination Address 200.1.1.1 10.0.1.1/24 192.168.1.1/24 Paragon4  (NAT Enabled)  Mobile Host 1 173.30.1.2/24 External Host 1 200.1.1.1/24Mobile 1 Network  External Network  4 Packet (2) Source Address 200.1.1.1 Destination Address 173.30.1.2 5 Packet (2) Source Address 200.1.1.1 Destination Address 173.30.1.2 RF Network 6 Packet (2) Source Address 200.1.1.1 Destination Address 173.30.1.1 1 Packet (2) Source Address 173.30.1.2 Destination Address 200.1.1.1 Mobile (G3) (NAT Disabled) 10.0.1.2/24 173.30.1.1/24 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   42Figure 31 - Paragon4 - Example 4 In example 4, Management Host 1 sends Packet (1) to External Host 1. Even though the packet comes from the private network, the source IP address does not. The Base station does not replace the source IP address of Packet (1). 6.8.4.2  NAT on the Mobile Unit (GeminiG3) When NAT is enabled on the Mobile Unit, the private network (from the point of view of the Mobile unit) is the IP network associated to the Ethernet 1 interface. Figure 32 - NAT Enabled on GeminiG3  External Host 1200.1.1.1/24 RF Network Public Network (External Network + RF Network + Mobile 2 Network + Management Network) Private Network 173.30.1.0/24 Base  (Paragon4)Ethernet 1 192.168.1.1/24Mobile Host 1173.30.1.2/24Mobile (G3)Mobile (G3)Ethernet 2 172.30.1.1/24 RF 10.0.1.2/24  RF 10.0.1.3/24 173.30.1.1/24  174.30.1.1/24 Mobile Host 2174.30.1.2/24 Mobile 2 Network External NetworkManagement Host 1 172.30.1.2/24 Management Host 2 172.30.1.3/24  Management Network RF 10.0.1.1/24 1 Packet (1) Source Address 174.30.1.2 Destination Address 200.1.1.1 2 Packet (1) Source Address 174.30.1.2 Destination Address 200.1.1.1 172.30.1.1/24 192.168.1.1/24Paragon4  (NAT Enabled)  Management Host 1 172.30.1.2/24 External Host 1 200.1.1.1/24Private network (172.30.1.0/24) Public network (External)  3 Packet (2) Source Address 200.1.1.1 Destination Address 174.30.1.2 4 Packet (2) Source Address 200.1.1.1 Destination Address 174.30.1.2 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   43Figure 33 - GeminiG3 - Example 1 In example 1, Mobile Host 1 sends Packet (1) to External Host 1.  Since the source IP address of Pack-et (1) comes from the private network, it gets replaced by the IP address of the RF interface of the Mobile unit. Figure 34 - GeminiG3 - Example 2 In this example, Mobile Host 1 sends Packet (1) to External Host 1.  Even though the packet comes from the private network, the IP source address is not part of the private network. The source IP address of Packet (1) does not get replaced by the Mobile unit.     2 Packet (1) Source Address 10.0.1.2 Destination Address 200.1.1.1 3 Packet (1) Source Address 10.0.1.2 Destination Address 200.1.1.1 10.0.1.1/24 192.168.1.1/24 Paragon4    Mobile Host 1 173.30.1.2/24 External Host 1 200.1.1.1/24Mobile 1 Network  External Network  4 Packet (2) Source Address 200.1.1.1 Destination Address 10.0.1.2 5 Packet (2) Source Address 200.1.1.1 Destination Address 10.0.1.2 RF Network 6 Packet (2) Source Address 200.1.1.1 Destination Address 173.30.1.1 1 Packet (2) Source Address 173.30.1.2 Destination Address 200.1.1.1 Mobile (G3) (NAT Enabled) 10.0.1.2/24 173.30.1.1/24  2 Packet (1) Source Address 174.30.1.2 Destination Address 200.1.1.1 3 Packet (1) Source Address 174.30.1.2 Destination Address 200.1.1.1 10.0.1.1/24 192.168.1.1/24 Paragon4    Mobile Host 1 173.30.1.2/24 External Host 1 200.1.1.1/24Mobile 1 Network  External Network  4 Packet (2) Source Address 200.1.1.1 Destination Address 174.30.1.2 5 Packet (2) Source Address 200.1.1.1 Destination Address 174.30.1.2 RF Network 6 Packet (2) Source Address 200.1.1.1 Destination Address 174.30.1.2 1 Packet (2) Source Address 174.30.1.2 Destination Address 200.1.1.1 Mobile (G3) (NAT Enabled) 10.0.1.2/24 173.30.1.1/24 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   446.8.4.3 SNMP Overview SNMP (Simple Network Management Protocol) is used by network management systems to manage and monitor network-attached devices. SNMP is based on the manager/agent model consisting of a manager, an agent, a database of management information, managed objects, and the network protocol. The manag-er provides the interface between the human network manager and the management system. The agent provides the interface between the manager and the physical devices being managed (Figure 35). SNMP uses basic messages (such as GET, GET-NEXT, SET, and TRAP) to communicate between the manager and the agent. Figure 35 - SNMP: manager/agent model  6.8.4.3.1 MIB  The manager and agent use a Management Information Base (MIB), a logical, hierarchically organized database of network management information. MIB comprises a complete collection of objects used to manage entities in a network. A long numeric tag or object identifier (OID) is used to distinguish each variable uniquely in the MIB and SNMP messages.  6.8.4.3.1.1 ParagonP4 MIB File Each ParagonP4 unit firmware package is bundled with three MIB files (found inside mibs.zip file): • dataradio-regs.mib: contains a top level set of managed object definitions aimed at managing Datara-dio products. • 1213.mib: contains a set of managed object definitions aimed at managing TCP/IP-based internets. • bsc.mib: contains a set of managed object definitions aimed at managing Dataradio BSC radio base stations.  6.8.4.3.1.2 OID In SNMP, each object has a unique OID consisting of numbers separated by decimal points. These object identifiers naturally form a tree. Figure 36 illustrates this tree-like structure for 1213.mib, which comes bundled with every ParagonP4 unit package. A path to any object can be easily traced starting from the root (top of the tree). For example, object titled “SNMP” has a unique OID: 1.3.6.1.2.1.11. The MIB as-sociates each OID with a label (e.g. “SNMP”) and various other parameters. When an SNMP manager wants to obtain information on an object, it will assemble a specific message (e.g. GET packet) that in-cludes the OID of the object of interest. If the OID is found, a response packet is assembled and sent back. If the OID is not found, a special error response is sent that identifies the unmanaged object.   MANAGER AGENTManagement Database Management Database Managed ObjectMessagesNetwork ProtocolManagement System Managed ElementHuman Network ManagerPreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   45Figure 36 - Branch of the 1234.mib OID tree  6.8.4.3.1.3 Viewing MIB files To view the hierarchy of SNMP MIB variables in the form of a tree and view additional information about each node, Dataradio recommends opening all MIB files with a MIB browser. In a MIB browser, each object (or node) can be selected and its properties (including its OID) can be observed.For simple networks, any MIB browser supporting SNMP v2c could be used. However, for managing complex net-works, a more advanced SNMP Manager/Browser is recommended. Refer to Dataradio Network Management using SNMP User Manual (Part no. 120 47001-nnn for more details). Note: Both “Read Community” and “Read/Write Community” passwords are required to operate SNMP MIB. For all Paragon base stations the same password is used for both read and read/write. This pass-word is the same password used to access the Paragon4 web pages.   6.8.4.3.1.4 bsc.mib  Figure 37 shows top-level objects of the bsc.mib file: • bscIdentity • bscRadioIdentity • bscStatistics • bscDiagnostics • bscControl • bscMobileTable  These six branches expand into additional branches and leaves. Again, all bsc.mib objects can be accessed through a MIB browser.   org (3)iso(1)ip(4)icmp(5) SNMP (11)udp(7)system (1)interfaces (2)dod (6)internet (1)mgmt (2)mib-2 (1)tcp (6) transmission (10)1.3.6.1.2.1 1.3.6.1.2.1.11 1 1.3.6 1.3 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   46Figure 37 - bsc.mib Tree   Note: For more details on Network Management using SNMP refer to Dataradio Network Man-agement using SNMP User Manual (Part no. 120 47001-nnn)     bscModule (1)bscIdentity (2)bscRadioIdentity (3) bscDiagnostics (5)bscStatistics (4)bscControl (6)bscMobileTable (7)bsc (3)base (1)............ ......1.3.6.1.4.1dataradio (3732)vis3network (5)Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   476.8.5 Setup (Advanced) ► IP addressing   For a description of the broadcast and multicast features of the Paragon4 radio modem, please refer to paragraph 5.7.3.5.1 below. Figure 38 - Advanced IP Configuration – IP addressing modes The IP Addressing web page contains two sections, the one on top controls the forwarding of IP broadcast packets and the other, on the bottom, controls IP multicast packets.  Each section acts independently.  Item  Description Broadcast Directed Broadcast  Disabled, Enabled (Default) – Controls forwarding of Directed Broadcast packets Limited Broadcast   Disabled (Default), Enabled – Controls forwarding of Limited broadcast packets   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   48Multicast Multicast  Disabled (Default), Enabled – Controls forwarding of Multicast packets (based on the “Multicast Address List”)  Multicast can be used when “one-to-many” communi-cation is required. Mobile unit address This multicast address represents the "All Mobile" group. When a Base station receives  an IP packet on its Ethernet interface and the destina-tion IP address matches this multicast address,  the IP packet is forwarded over the RF interface to all the Mobile units. The Mobile units will pass  this packet to their internal applications. Multicast Address List Add / Delete Address The multicast address list is used to enter multicast addresses for the various "Mobile Hosts" groups. When a Base station receives an IP packet on its Ethernet interface and the destination IP address matches one of these address, the IP packet is for-warded over the RF interface to all the Mobile units. If multicast forwarding is enabled on the Mobile units, the IP packet will be forwarded to the Mobile's Ethernet interface, Mobile Hosts will then be able to receive the packet.  The Mobile units have some additional filtering capa-bilities. To add an address to the Multicast List:                    Select the “Add”  option button and type in the dialog box the new address to be added to the  read-only        “Address List”. Note that only valid multicast ad-dresses will be accepted and displayed.  To delete an address from the Multicast List: Select the “Delete” option button and type in the dialog box the address to be deleted from the “Address List”.  Address List Read-only listing. Window expands downward as needed to show all addresses in the list. When an IP packet is received on the Ethernet side of the unit and the destination IP address matches one of the multicast IP addresses in this list, it is forwarded over the RF interface.  Remote units will send it over their Ethernet interface.    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   496.8.5.1  IP Broadcast/Multicast Overview When an IP packet needs to reach more than one unit, the destination address can be set to either a broad-cast address or a multicast address. 6.8.5.1.1 Broadcasts Figure 39 - Broadcast Window Detail  There are two types of IP broadcast addresses:  • Directed broadcast  A directed broadcast address is an IP address where the host portion is all ones (for instance 172.30.1.255 is the directed broadcast address for the network 172.30.1.0/24, 172.30.1.207 is the directed broadcast address for the network 172.30.1.192/28).  • Limited broadcast The limited broadcast address is 255.255.255.255. Note: Routing equipment (to prevent broadcast storms) do not by default forward limited broadcast packets (255.255.255.255). On the other hand, directed broadcast packets are by default forwarded because these packets are routable like any other unicast packets.  6.8.5.1.1.1 Directed Broadcast Each interface of a unit has its own IP address and netmask. From the IP address and netmask, it is easy to calculate the broadcast address associated to the interface. For instance, if the Ethernet interface ad-dress of a GeminiG3 radiomodem is 172.30.1.1/24 and the RF interface address is 10.0.1.2/24, then the broadcast address of the Ethernet interface is 172.30.1.255 and the broadcast address of the RF interface is 10.0.1.255. The “Directed Broadcast” option buttons let the user select whether the unit must forward (or not) di-rected broadcast packets. Upon reception of a directed broadcast packet, the unit takes the following ac-tions: If the directed broadcast address matches with one of the unit’s interface broadcast addresses: • Keep a copy for itself (pass to internal applications, if any). • If directed broadcast packets can be forwarded (Directed Broadcast is enabled): Forwards the packet according to the routing table. • If directed broadcast packets cannot be forwarded (Directed Broadcast is disabled): Silently discards the packet.  Note:  Occasionally, the unit cannot determine that the packet is actually a directed broadcast. In such a case, the packet is normally routed. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   50 Example (Directed Broadcast forwarding enabled)  Figure 40 - Example of Directed broadcast forwarding enabled In this example (Figure 40), directed broadcast forwarding is enabled on the Base unit and on Mobile (1) unit. If Sender wants to reach Mobile Host (1),  Mobile Host (2) and Mobile Host (3) with a single packet, he can send to destination address 172.30.1.255.               Sender  Base (P4) RF AirlinksMobile Host(2)172.30.1.3/24Mobile Host(3)172.30.1.4/24Mobile (1) 172.30.1.1/24 Mobile (2) 172.30.3.1/24 Mobile Host(1)172.30.1.2/24Mobile Host(4) 172.30.3.2/24 Directed broadcast forwarding enabled Directed broadcast forwarding enabled Send to 172.30.1.255 10.0.0.1/8 10.0.0.2/8  10.0.0.4/8 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   51Example (Directed Broadcast forwarding disabled) Figure 41 - Example of Directed broadcast forwarding disabled  In this example (Figure 41), directed broadcast forwarding is enabled on the Base unit and disabled on the Mobile (1) unit. If Sender sends a packet to destination address 172.30.1.255, the packet would be dis-carded by Mobile (1), it would not reach Mobile Host (1), Mobile Host (2) and Mobile Host (3).  If the user wants the Base unit to do the discarding of the directed broadcast packets, then the directed broadcast forwarding must be disabled on the Base unit itself.   6.8.5.1.1.2  Limited Broadcast  The “Limited Broadcast” enabled/disabled option buttons control limited broadcast packets forwarding. When enabled, the unit forwards limited broadcast packets.  Upon reception of a limited broadcast packet, the unit takes the following actions: • Keeps a copy for itself (passes to internal applications, if any). • If limited broadcast packets can be forwarded (Limited Broadcast is enabled):  Sends a copy of the packet out to all the interfaces with the exception of the interface where the pack-et was received. • If limited broadcast packets cannot be forwarded (Limited Broadcast is disabled): Silently discards the packet.    Sender Base (P4)Mobile (1) 172.30.1.1/24Mobile (2) 172.30.3.1/24 10.0.0.1/8 10.0.0.2/8  10.0.0.4/8 Directed broadcast forward-ing enabled Directed broadcast forward-ing disabled Send to 172.30.1.255 Mobile Host(2) Mobile Host(3) Mobile Host(1) Mobile Host(4) Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   52Example (Limited Broadcast forwarding enabled) Figure 42 - Example of Directed broadcast forwarding enabled  In this example, (Figure 42) limited broadcast forwarding is enabled on the Base unit and on all Mobile units. If Sender wants to reach Mobile Host (1), Mobile Host (2) and Mobile Host (3) and Mobile Host (4) with a single packet, he can send to destination address 255.255.255.255. Notice that Sender and Base units are on the same LAN (routing equipment does not usually forward limited broadcast packets).     Base (P4) RF AirlinksMobile Host (2) Mobile Host (3) Mobile (1) 172.30.1.1/24Mobile (2) 172.30.3.1/24 Mobile Host (1) Mobile Host (4) 10.0.0.1/8 10.0.0.4/8 Limited broadcast forwarding enabled Limited broadcast forwarding enabled Send to 255.255.255.255 Limited broadcast forwarding enabled Sender  10.0.0.2/8 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   53 Example (Limited Broadcast forwarding disabled)  Figure 43 - Example of Limited broadcast forwarding disabled  In this example (Figure 43), limited broadcast forwarding is enabled on the Base unit, disabled on the Mobile (1) unit and enabled on the Mobile (2) unit. If Sender sends a packet to destination address 255.255.255.255, the packet would reach Mobile Host (4) only.  The Mobile (1) unit would discard any limited broadcast packet it received from the Base unit.   If the user wants the Base unit to do the discarding of the limited broadcasting packets, then the limited broadcast forwarding must be disabled on the Base unit itself. Then no Mobile Host unit would ever be receiving a limited broadcast packet.      Base (P4) RF AirlinksMobile Host (2)172.30.1.3/24Mobile Host (3)172.30.1.4/24Mobile (1) 172.30.1.1/24Mobile (2) 172.30.3.1/24 Mobile Host (1)172.30.1.2/24Mobile Host (4) 172.30.3.2/24 10.0.0.1/8 10.0.0.4/8 Limited broadcast forwarding enabled Limited broadcast forwarding disabled Send to 255.255.255.255 Limited broadcast forwarding enabled Sender  10.0.0.2/8 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   54 6.8.5.1.2 Multicast IP multicast addresses are in the range 224.0.0.0 to 239.255.255.255. These addresses are used to represent logical groups of units that may or may not reside on the same networks. Multicast is used when “one-to-many” communication is required. For instance, a radio station might of-fer a music channel on the Internet in real time. To receive the music a receiver-host must know the mul-ticast group (multicast address) used by the radio station sender-host and add itself as a member of this group. In the IP realm, a host uses the IGMP protocol to do this. The routers inside the Internet are using IGMP and other multicast routing protocols to build the proper path from the sender to the receivers (a tree-like path is formed from the sender to the receivers). Figure 44 - Registration to multicast group (First step)  Figure 45 - Reception of multicast packets (Second step)  Sender (owner of multicast group 226.1.2.3)Receiver 1  (member of 226.1.2.3) Receiver 2 (member of 226.1.2.3)Receiver 3  (member of 226.1.2.3)Internet IP RouterIP RouterIP RouterIP Router Paths from Sender to Members (Receivers 1, 2, and 3) flow in the Internet from IP Router to IP Router to reach  destinations 226.1.2.3. Paths are not forwarded over inter-faces that do not lead to a multicast group member 5 122334Receiver  (not a member of 226.1.2.3)Receiver (not a member of 226.1.2.3)  Sender (owner of multicast group 226.1.2.3) Receiver 1  (Add membership 226.1.2.3)Receiver 2 (Add membership 226.1.2.3)Receiver 3 (Add membership 226.1.2.3) Internet Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   55 Sender Network   “All Mobile”   Base (P4) Base (P4)RF Air-Mobile  Mobile  Mobile  Mobile  Mobile “Mobile Host” group 1 “Mobile Host” group 2Mobile Mobile  Mobile Mobile Mobile In the E-DBA environment, an outside sender-host might be interested in sending multicast packets to any one of the following groups: • “All Mobile” group. • Various “Mobile Host” groups. The Base (P4 in the illustration) units are directly connected to the outside network. ALL multicast groups MUST be identified in the Base because the Base unit uses IGMP to register the memberships to the multicast groups on behalf of the other units (Mobile units, Mobile Host units). Figure 46 - Typical E-DBA Multicast Groups Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   56The following setup example would allow the “Sender” unit to communicate with different multicast groups. The settings shown in Figure 47 below, and also represented in  Figure 48, would enable the Sender unit to reach all entities of the various groups.  Figure 47 - Multicast Window Details (On the Base station)  Multicast (Enabled/Disabled)  Enables or disables the registration of the multicast groups by the Base Mobile address  Indicates the “All Mobile” multicast group Multicast Address List  Indicates the various “Mobile Host” groups  Figure 48 - Typical E-DBA Multicast Groups (with addresses)    Sender  Network   “All Mobile” group(224.168.201.1)   Base (P4) Base (P4) RF AirlinksMobile Host Mobile Host Mobile Host Mobile Host Mobile Host “Mobile Host” group 1(224.168.200.1) “Mobile Host” group 2 (224.168.200.2) Mobile (G3) Mobile (G3) Mobile (G3) Mobile (G3) Mobile (G3) Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   576.8.6 Setup (Advanced) ► IP Optimization Figure 49 - Setup (Advanced)-Optimized IP Settings  Item  Description RF ACK Disabled (Default) - TCP packets are always RF acknowledged regard-less of this option setting. Enabled - Use when packets need to be acknowledged at the RF level by the remote unit (destination unit). This option is applicable to all packet types other than TCP. OIP Retries  Number of OIP retries. Default = 2 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   586.8.7 Setup (Advanced) ► IP Route Displays the table of IP routes that are active in the Paragon4 base station. Typically, display shows routes for RF, ETH1, and ETH2. Figure 50 - IP Routing    Item  Description IP Address  The address portion of the destination network Netmask  The mask portion of the destination network Gateway  IP Address: The IP address of the gateway to use when trying to reach the given network Type Static: routes added by the user Connected: addresses that are directly reachable by one of the inter-faces Proprietary: routes added internally by the Mobile registration process Add / Delete Allows the user to add or remove routes manually to/from the table.   Warning: Manipulate this table with caution!  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   596.8.8 Setup (Advanced) ► Time Source To facilitate tracking of events in a network, the Paragon4 base station and the GeminiG3 unit can initial-ize their real-time clocks using a number of protocols. At reset time, the Paragon4 unit can use the SNTP protocol (RFC2030) to pick up the current UTC (Universal) time. Setting the “TimeZone” and “Daylight Savings” options allows displaying the correct local time in the “Unit Identification and Status” page. Figure 51 - Advanced IP Configuration – Time Source  Item  Description SNTP Client  Disabled (Default), Enabled Server address  IP of the SNTP Server in dot decimal format Period  Period at which the SNTP Server is polled SNTP UTC Time  SNTP UTC Time  Last update received from the SNTP Server (in seconds) - Read-only field. Time Zone TimeZone  Select from drop-down list Daylight Savings  Disabled (Default), Enabled Note: Due to transitional nature of Daylight Saving in many jurisdictions, we recommend that customers use UTC for consistent, unambiguous time reporting, setting TimeZone to UTC and Daylight Saving to Disabled. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   606.8.9 Setup (Advanced) ► Ethernet (PHY) The Ethernet port(s) must be configured in a mode that is compatible with the other local devices.  Figure 52 - Advanced IP Configuration – Ethernet (PHY)  Item  Description ETH1 PHY PHY Bitrate Auto Negotiate Force to 100 Mbps Force to 10 Mbps (Default) PHY Duplex  Displays factory configured mode of operation: Auto Negotiate ETH2 PHY PHY Bitrate Auto Negotiate Force to 100 Mbps Force to 10 Mbps (Default) PHY Duplex  Displays factory configured mode of operation: Half Duplex    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   616.8.10 Setup (Advanced) ►Diagnostic Settings Figure 53 - Advanced IP Configuration – Diagnostic Settings   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   62Item  Description Analog alarms trap conditions Analog Monitoring Rate  Frequency at which internal values are updated and checked against the alarm boundary conditions. Ranges from 100milliseconds to infinity. Default = 500ms Analog alarms settings For each diagnostic value displayed, the user can control alarms trap conditions in the following ways:  Set acceptable range of values by entering the low and high thre-sholds  Choose to be notified when the value goes out of acceptable range by selecting the “goes out of range” check box  Choose to be notified when the value returns into acceptable range by selecting the “returns into range” check box All monitoring combinations are possible  Digital  Alarms trap conditions Digital Alarms settings For all digital alarms, the traps can be sent when:  “Asserted:-The digital signal changes from low to high  “Unasserted”-The digital signal changes from high to low All monitoring combinations are possible Hardware fault trap conditions  Receiver Comparison To diagnose a  possible receiver malfunction   Choose to be notified when a Receiver Comparison fault occurs by se-lecting the "Fault" check box.   Choose to be notified when a Receiver Comparison fault has been cor-rected by selecting the "Fault cleared" check box.  Calibration Files Calibration Files All Paragon4 unit firmware comes bundled with two interpolation files used for forward and reverse power calibration. These files are required to be used with the optional external power sensor assembly (p/n 030 03547-xxx). Caution: Forward & reverse power readings will not be accurate without the optional external power sensor assembly (p/n 030 03547-xxx).  Refer to your Dataradio sales channel for details. The file names entered in this section should match the file names in your unit (Note: file names are case sensitive.) These files are needed to properly display the Forward and Reverse power values.   6.8.10.1  Calibration Files  Special electrical sensors are used to measure the values of real world quantities such as forward or re-verse RF power. These sensors represent all measurements in Volts and require a conversion to proper units where applicable. This conversion is achieved by use of mathematical transfer functions, which also provide a way of calibrating the sensor hardware.  The transfer function can be represented by a simple look-up table that approximates a continuous func-tion by a series of data points. Each data point represents an {Xin, Yout} pair, where Xin is the sensor’s output-a measurement in Volts, and Yout is the corresponding value in a desired unit of measurement. Li-near interpolation is used to generate Yout values for any given Xin value in between the data points sup-plied in the look-up table. The series of data points in a look-up table are listed in a text calibration file and is read by the Piecewise Linear Interpolation Calibrated Conversion (PWLICC) software module, employed in Paragon4 radio base station to convert the sensor output into a desired value. Dataradio supplies look-up tables for forward and reverse power measurements. These tables contain a set of values in Volts (Xin) with their corresponding values in Watts (Yout). Similar look-up tables need be created for user-supplied external analog devices connected to the base station’s backplane for diagnostics and monitoring if other than voltage measurement units are preferred.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   63An example of a look-up table is presented in Table 5 with a corresponding graph in Figure 54 Table 5 - Sample Interpolation endpoints Figure 54 - Sample Interpolation curve   Values in-between the data points are calculated using a straight line between the closest two known data points. At least 2 data points are required; however 10 or 20 data points (up to 50) are usually necessary (depending on the curves behavior).   A look-up table can be created with a simple text editor, such as MS-Notepad, carefully following the guidelines presented below. The basic syntax is summarized in Table 5. • // symbol preceding any entry denotes comments. • [c] symbol preceding a string of up to 80 characters denotes file description. This string will be dis-played under “description” field on the “Diagnostics Settings” page of the Pargon3 web interface. • [u] symbol preceding a string of up to 15 characters denotes the desired unit of measure.  • [n] symbol preceding an integer denotes the number of entries in the look-up table.  • Data points are filled in as {Xin, Yout} pairs. Each pair occupies a line and counts one space in be-tween its elements: Xin1Yout1 Xin2 Yout2 Xin3 Yout3  …….. • The number of {Xin, Yout} pairs must correspond to the index ([n]) entered. • Empty lines are not accepted-use comments for formatting. • Duplicate Xin values are not accepted. Xin (Volts)  Yout (Desired Units) 0.0 0.0 0.2 1.0 0.375 2.0 0.530 3.0 0.530 4.0 00.511.522.533.544.50 0.2 0.4 0.6 0.8Xin (Volts)Yout (Desired Units)Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   64• When complete, use the “Save As” command.  • The file name is case-sensitive and spaces are not allowed.  • The file name should be saved under .pli extension.  • The file should be uploaded into a unit using FTP transfers. • The file’s name should be entered under “Analog monitoring 1 calibration” (and/or “Analog monitor-ing 2 calibration”) field on the Diagnostic page of the Paragon4 web interface.  Table 6 - PLICC Syntax Syntax  Description // <comment>  Comments.  Optional [c] <name> Descriptive name of the look-up table (string of 80 characters max). This field will appear under the “description” field on the Diagnostics Settings” page of the Pargon3 web interface.  Optional [u] <unit>  Unit of measure (string of 16 char maximum).   Optional [n] <index>  Number of entries in the table (2 minimum, 50 maximum).   Required  Failure to comply with the guidelines described above may result in the following errors: Table 7 - Possible Error messages Error  Description No file found  The file name entered is not found on the unit. Bad header or bad file format found.  Syntax Error . No data found.  No data entered in the file (less than 2 data points). More than 50 segments found in file.  The file counts more than 50 data points. Duplicate X values found in data.  The file contains duplicate Xin values.   A sample calibration file is presented in Figure 55. Please note the following: 1. “Volts to watts conversion” will appear under the “description” field on the “Diagnostics Settings” page of the Pargon3 web interface.  2. This look-up table contains a set of values in Volts with their corresponding values in Watts. 3. This look-up table contains five data points.  4. The number of data points should correspond to the index (entered under [n]). All Xin entries (voltage values) must be unique.  // file name: sample_calibration_file.pli  // Revision: N.NN // Date: YYYY/MM/DD // Other Comments  [c]Volts to watts conversion [u]Watts [n]5 0.000 0.0 0.200 1.0 0.375 2.0 0.530 3.0  0.530 4.0  Figure 55 - Sample calibration file  2 3 1 4 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   656.8.11 Setup (Advanced) ►User Settings  Figure 56 - Advanced IP Configuration - User Settings   Item  Description Temperature Display  Celsius (default)/Fahrenheit Select desired temperature scale. Where applicable, the temperature will be displayed in selected tempera-ture scale. Power Unit  Watts (default)/ dBm  Select desired power scale. Where applicable, the power will be displayed in selected power scale.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   666.9  Security 6.9.1 Security ► Password and Encryption Control The Setup web pages, the CLI (command line interface) and the FTP server all require a password to pre-vent unauthorized users from changing a unit’s configuration. At the time of manufacture, the password is set to “ADMINISTRATOR” but Dataradio strongly suggests that the password be changed as units are installed.  Figure 57 - Security – Password and Encryption Item  Description User ID Enter a string of any letters or numbers of at least 1 and not exceeding 15 characters The User Name entry is currently not an access-limiting factor. It only serves to identify the person gaining access. User Name may be required by future versions. Old Password  For an initial installation, enter the default Password ADMINISTRATOR (all upper case letters). For subsequent access, use the Password that you will have configured. New Password Enter a string of any letters or numbers of at least 8 and not exceeding 15 characters CAUTION: Do not lose the new password or you will not be able to gain access to the unit; you will need to contact CalAmp support. New Password (confirm)  Re-enter the new password string  Encryption  Disabled, Enabled (Default) Encryption Pass Phrase String of characters used to create a 128-bit AES encryption key. The Pass Phrase can be up to 160 characters long. Using a length of at least 128 characters should provide an adequate security level for most users. A good pass phrase mixes alphabetic and numeric characters, and avoids simple prose and simple names.  Encryption Key  All units in a network must have the same key.  READ ONLY - Displayed in pairs separated with spaces Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   676.9.2 Security ► Access Control Figure 58 - Security - Access List Item  Description Access List Control  Access List Control Access List is used to keep unauthorized unit(s) away from Dataradio RF network. Maximum number of Access List entries = 100. The Access List Control takes the following values: Disabled (Default) Allow or Deny – Authorized units only. Requests from any unit(s) outside this list will be rejected. Access List Management Add Entry  Adds entry in the Access Control List Delete Entry  Deletes entry in the Access Control List Import Access list from file Imports Access List from file – Populates Access Control table from the file “accesslist.acl“. It is basically a text file that contains a list of RF MAC addresses. E.g.:  0x1234 abcd 2345 where, 0x1234, abcd, and 2345 represent RF MAC addresses in HEX To use this feature:  -Create a text file “accesslist.acl” with a list of RF MAC addresses -Upload the file from a host PC via an FTP program -Click on “Import Access list from file” button -Click on “Display Access List” button to view the imported access list  Clear Access List  Clears entire Access Control table Display Access List  Clicking this button opens the access list in the message window    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   686.10 Statistics Statistics web pages allow the user to view data transmission statistics (Interfaces) and base station per-formance (Channel Utilization).  6.10.1 Statistics ► Interfaces Figure 59 - Statistics – Interfaces Item  Description LAN(ETH1)  RX Pkts  Total number of packets received by Ethernet 1 interface TX Pkts  Total number of packets transmitted by Ethernet 1 interface LAN(ETH2)  RX Pkts  Total number of packets received by Ethernet 2 interface TX Pkts  Total number of packets transmitted by Ethernet 2 interface RF RX Pkts (RF-OIP)  Total number of packets received by RF-OIP interface TX Pkts (RF-OIP)  Total number of packets transmitted by RF-OIP interface RX Ctrl Pkts (RF-Airlink)  Total number of control packets received by RF-Airlink interface RX Data Pkts (RF-Airlink)  Total number of data packets received by RF- Airlink interface TX Ctrl Pkts (RF-Airlink)  Total number of control packets transmitted by RF- Airlink inter-face TX Data Pkts (RF-Airlink)  Total number of data packets transmitted by RF- Airlink inter-face Airlink error  correction Packets with no error  Number of E-DBA packets, control or data, received over-the-air with zero error. Packets corrected  Number of E-DBA packets, control or data, received over-the-air with correctable errors. Packets not correctable  Number of E-DBA packets received over-the-air with errors that could not be corrected. These packets were discarded.    Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   696.10.1.1  Interface Statistics Conventions  To reduce their design complexity, most networks are organized as a series of layers or levels, each one built upon its predecessor. Layer n on one machine carries on a conversation with layer n on another ma-chine. The rules and conventions used in this conversation are collectively known as the layer n protocol. The number of layers, the name of each layer, the contents of each layer, and the function of each layer differ from network to network.  Figure 60 below illustrates layers and protocols applicable to Dataradio network architecture implementa-tion. The five basic layers are: • Physical Layer  • Datalink Layer • Network Layer • Transport Layer • Application Layer Figure 60 - Layers and protocols applicable to Dataradio implementation In reality, no data are directly transferred from layer n on one machine to layer n on another machine. In-stead, each layer passes data and control information to the layer immediately below it, until the lowest layer is reached (Figure 61).  Paragon4 radio base station web interface presents data transmission statistics for the Datalink layer. Network and Transport layers statistics are not accessible through the web interface; they are provided in 1213 MIB and can be accessed through a MIB browser or an SNMP manager (see section 6.8.4.3: SNMP Overview for more details on 1213 MIB).    TRANSPORT LAYERNETWORK LAYERDATALINK LAYERPHYSICAL LAYERTCP UDPIPETH2ETH1RF-OIPETH PHY ETH PHYEDBA PHYFECRF-AIRLINKHTTP SNMP FTPAPPLICATION LAYERPreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   70Figure 61 - Layer, protocols, and interfaces applicable to Dataradio implementation  All statistics presented by Dataradio follow a convention presented in Figure 62. Layer n statistics are given with respect to the layer immediately below it: layer n-1. RX (Receive) or IN refers to data received by layer n from layer n-1. Transmit (TX) or OUT refers to data transmitted by layer n to layer n-1. Figure 62 - RX and TX Convention  6.10.1.1.1  Datalink Layer Statistics Datalink layer comprises two Ethernet interfaces (ETH1 and ETH2) and an RF interface. Ethernet1 and Ethernet2 interfaces statistics are illustrated in Figure 63.  Layer NLayer N+1Layer N-1RX/INTX/OUTConventionTRANSPORT LAYERNETWORK LAYERDATALINK LAYERPHYSICAL LAYERHTTP SNMP FTP APPLICATION LAYERHOST ATCP UDPIPTRANSPORT LAYERNETWORK LAYERDATALINK LAYERPHYSICAL LAYERETH2ETH1RF-AIRLINKRF-OIPLayer P/D InterfaceLayer D/N InterfaceLayer N/T InterfaceETH PHY ETH PHY EDBA PHYFECLayer T/A InterfaceAPPLICATION LAYER HTTP SNMP FTPHOST BTCP UDPIPETH2ETH1RF-AIRLINKRF-OIPLayer P/D InterfaceLayer D/N InterfaceLayer N/T InterfaceETH PHY ETH PHYEDBA PHYFECLayer T/A InterfaceTRANSPORT MEDIAPreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   71Figure 63 - Datalink Ethernet Statistics   RF interface is further subdivided into two sub-layers: OIP sub-layer and Airlink sub-layer. OIP (Opti-mized IP) sub-layer is concerned with compression, optimization, TCP proxy control, and IP roaming. Airlink sub-layer is where Dataradio’s Enhanced Dynamic Bandwidth Allocation (E-DBA) Airlink proto-col resides.  RF interface statistics are illustrated in Figure 64. Each E-DBA cycle consists of a fixed number of con-trol packets (e.g.: Requests, Acknowledgements, etc...) and a dynamically allocated number of data pack-ets. This is why both Data and Control packets count appear at the Air link sub-layer. RF interface statistics also include error correction statistics for all incoming packets. The corrections are accomplished with a forward error correction (FEC) module. The advantage of forward error correction is that retransmission of data can often be avoided. Figure 64 - Datalink RF Statistics DATALINK LAYERPHYSICAL LAYERETH1RF-AIRLINKRF-OIPETH PHYEDBA PHYFECTx PktsRx PktsETH2ETH PHYTx PktsRx PktsPreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   726.10.2 Statistics ► Performance Figure 65 - Statistics - System Performance  Item  Description Number of Mobiles Registered: Records the maximum number of mobiles registered at any time over the statistics period Active: Records the number of mobiles that have actively transmitted or received data during the statistics period. This value can be larger than the number of Registered mobiles for a period if enough mobiles have registered and then roamed away from the base during the statis-tic period.  Channel Throughput  Outbound: Records the number of data packets sent outbound during the statistics period. The number of packets sent so far during the Current period is shown, as is the Largest value recorded for any pe-riod. Inbound: Records the number of data packets scheduled for inbound during the statistics period. The number of packets scheduled so far during the Current period is shown, as is the Largest value recorded for any period. (The number of packets scheduled may not match the number of packets actually received. See Statistics → Interfaces page for counts of the number of packets received.  The Clear 'Largest' Stats button clears the two values in the Largest column. The Largest values can be used to compare the current set of statistics with the busiest outbound & inbound periods. Average Outbound Delivery Time  Records the average time from which an outbound IP message is pre-sented to the airlink until the RF acknowledgement for that message is received. Broadcast/Multicast messages that are not acknowledged do not contribute to the statistic, nor are outbound messages that retry and fail to reach their destination mobile.  An increasing Average Outbound Delivery Time is usually an indica-tion of increasing traffic on the RF channel but Delivery Time can also be affected by an increase in the number of retries needed to reach distant mobiles.  Note: The Average Delivery time for each registered mobile is also available on the Remote Table page.  Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   73Request Loading  Records the percentage of occupied Request slots compared to the number of slots made available by the base during the statistics pe-riod. A loading of 40% or more would indicate a very busy channel.  A network whose mobiles send data inbound in very short bursts (eg. license plate inquiries) may see a busy channel due to request loading even though the inbound channel throughput value is comparatively low. Roll statistics every ... seconds  Sets the statistics period to the specified number of seconds. The change takes effect immediately and the existing history is not cleared so the history may appear inconsistent until values recorded using the old period have rolled off the table. Refresh  This button refreshes the displayed statistics.   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   746.11 Maintenance 6.11.1 Maintenance ► Ping Test To aid in trouble-shooting IP connectivity issues, the Paragon4 base stations and the GeminiG3 mo-biles can transmit ping packets to a given IP address. Four packets are sent and the time taken for each to reach the destination and return is displayed. Figure 66 - Maintenance – Ping Test Item  Description Enter IP address  Enter IP address to ping, in dot decimal format Execute  This button executes the ping command. Ready field displays the outcome of the ping command.     Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   756.11.2 Maintenance ► Config Control Figure 67 - Maintenance -Configuration Control (Initial screen) Item  Description User Configuration Settings  Checkpoint User Configuration -saves a set of the current user configu-ration settings in the Paragon4 base station. Click on the Checkpoint User Configuration radio button. Click  Pro-ceed to save the settings to the configuration file. The new configura-tion file's name will consist of UserCfg_ and the Paragon4's ETH1 MAC address. (Example: UserCfg_000A99012345.drp). If a previous check-point had been saved to the UserCfg_macaddress.drp file then the new checkpoint will overwrite the existing file. Click “Export last Checkpoint to PC” link to save the configuration file to a PC. A save dialog box will appear. Select the file name and folder to save the configuration file to and click save.   The configuration file may be renamed, if desired, (must keep the .drp extension) then reloaded back into the original Paragon4 or into anoth-er Paragon4 by using an FTP client. Do not load more than 5 separate configuration files into a single Paragon4. Loading many configuration files into a Paragon4 may use up an excessive amount of memory and may cause the Paragon4 to malfunction. After saving the configuration file back into the Paragon4 with an FTP Client, select Import Configura-tion from and follow the instructions below. Import Configuration from  To restore a user configuration, click the Import Configuration from radio button. The drop down combo box will show all the .drp files (configuration files) in the Paragon4. Select the configuration file to load and click on Proceed. Click Save Config then Reset Unit to com-plete the process and store these settings to the unit.  Firmware Upgrade Settings Merge settings bundled in upgrade package with current configuration-merges upgraded settings with the current configuration. Note: the "firmware update" process will end up replacing an existing configuration file with the one that came bundled with the firmware upgrade package. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   76Factory Settings Restore Factory Settings: restores all settings do default factory confi-guration. Upon performing the firmware upgrade, should you decide to restore to factory settings instead of to “merge with bundled settings”, simply select the “Restore Factory Settings” option button right after perform-ing the firmware upgrade and click on “Proceed”. Important note:  Activating “Restore Factory Settings” will reset the IP address of the unit. Have your record of all the original Paragon 3 factory settings handy before proceeding with restoring to factory settings.  6.11.3 Maintenance ► Package Control Figure 68 - Maintenance – Package Control   Item  Description Package Control Used for verifying the field upgrade of the Paragon4 radio modem firmware.  The firmware transfer procedure outlined in section 7.5.1 instructs to “Click on Maintenance / Package Control to verify integrity and wait a few moments for the results to display”.  Figure 68 above shows a “Pass” result indication.  If an upgrade problem arises and persists, click the “Package Control” once more and have the resulting indications handy if contacting Dataradio  System Engineering.   Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   776.11.4 Maintenance ► RF Tests Test Tones: Select the desired test tone, press the “Execute” button to transmit a test signal on the current channel for 20 seconds or until the “Cancel current test” button is pressed.  The functions of all the other buttons are inoperative during test transmissions. Figure 69 - Control - RF Tests Test Tones Modulated Test transmission generates a carrier modulated with a 1 kHz test tone to check deviations. For specific deviation values, see  Carrier Modulation SRRC4FSK  SRRC8FSK  SRRC16FSK    Tone      Tone     Tone Network Speed (kb/s)Typical dev-iation in kHz Network Speed (kb/s)Typical dev-iation in kHz Network Speed (kb/s) Typical dev-iation in kHz(1000Hz test tone)  (1000Hz test tone)  (1000Hz test tone) Full Channel (UHF) 25 kHz bandwidth  32  ± 3.5  48  ± 4.1   64  ± 4.2        43.2  ± 4.2       Half Channel (UHF) 12.5 kHz bandwidth  16  ± 1.5   24  ± 2.1  32  ± 2.2  Wide Channel (700MHz) 50KHz bandwidth 64  ± 5.8  96  ± 6.7  128  ± 6.7 Full Channel (700MHz) 25KHz bandwidth 32  ± 2.5   48  ± 2.9  64  ± 2.9        43.2  ± 3.0       Half Channel (700MHz) 12.5KHz bandwidth 16  ± 1.3   24  ± 1.4  32  ± 1.5  Full Channel (800MHz) 25KHz Bandwidth 32  ± 2.4  48  ± 2.8  64  ± 2.8       43.2  ± 3.2       NPSPAC Channel (800MHz USA-only) 12.5KHz Bandwidth 16  ± 2.1  24  ± 2.5  32  ± 2.5 Table 10 - Carrier Deviations Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   78Unmodulated Test tone is an unmodulated carrier that gives a clear carrier and used for checking: ♦ Frequency error  ♦ Forward and reverse power Power check: Connect an in-line power meter between the radio and the antenna.  Measure the forward (nominal 70W (700 & 800 MHz models) or 100W (UHF model)) and re-flected power levels by pressing the Execute button. For reflected power, never exceed 5% of forward power or as specified by System Engineering. 100 Hz square wave Starts a test transmission of a carrier modulated by a square wave. Used to check low-frequency balance at a frequency of 100 Hz Random Data Starts a 20-second test transmission with a carrier modulated with random data Random data test transmissions are used for checking low-frequency balance and maxi-mum deviation over data. • Low-frequency balance check:  Helps to determine if the radio transmitter is well balanced for data transmission.  Refer to the User manual for values indicated in adjustment tables under “Low Fre-quency Balance” step. • Maximum deviation check: Helps to verify if the unit is within FCC regulation emission masks.  Refer to the User manual for values. Random data test requires the use of an IFR COM-120B service monitor with option 03= 30 kHz IF filter and its DC coupled demodulator output selected. Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   796.11.5 Maintenance ► Feature Options Refer to your Dataradio technical support or sales representative for options availability and cost.   Figure 70- Maintenance – Available Feature Options 6.11.6 Maintenance ► RSSI Display  Figure 71 - Maintenance – RSSI Display  Item  Description RSSI RSSI Table  Main -120 = dBm value from main radio receiver Diversity -120 = dBm value from diversity radio Range  -120 to –40 dBm  Thresholds  -90 to -60 dBm   Paragon4 Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   806.11.7 Maintenance ► System Log Figure 72 - Maintenance –System Log Item  Description System Log  Records critical events resulting from unexpected conditions during the unit operation. Refresh  Updates the screen to reveal latest log entries. Erase Log Deletes all log entries (lost forever).  Note: The system log is a limited reserved area of the flash memory. Once full, the new events will not get recorded. It is recommended to perform an Erase Log every so often.    6.11.7.1  Reading the Log Entries The system log records critical events resulting from unexpected conditions during Paragon4 base station operation. Information from this system log can be useful in understanding specific issues. Have the re-sulting indications handy if contacting Dataradio support.  A system log entry contains the following parts (see Figure 73): • A record number,  • A time stamp, • Time in MSec since last unit rest, • Chassis temperature, and • The event itself Figure 73 - A system Log Entry   Record NumberTime StampTime in Msec since last unit resetChassis TemperatureEvent Preliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   81Note: Log information will be preserved across system restarts or faults.  The general categories of events that can be found in the system log are: • Asserts: undesirable conditions (faults) • Resets: reasons for various system resets • Others: warnings, recovery from a fault, etc 6.11.7.1.1 Asserts An Assert log entry will normally display an exit code, a module number, and a line number indicating where the error occurred. See  Figure 74  for an example of an Assert log entry. This information will al-low Dataradio support team to determine the component and the reason of an error so that a corrective action could be recommended.  Figure 74 - An Assert type system log entry Note: “0x0” exit code signifies normal (non-faulty) system exit. 6.11.7.1.2 Resets A Paragon4 unit may be reset manually (through the Web interface, a telnet shell, or SNMP control) or automatically (as a result of the unit’s own monitoring facilities). Below are some examples of Reset log entries: Reset issued by a shell command:  [5  1970-01-01 01:03:45 3827.924  37 C] stationReset: board hard reset  Reset issued through the WEB Interface:  [10  1970-01-10 21:49:00 856116.827  38 C] HTTP server reset [11  1970-01-10 21:49:00 856116.842  38 C] Exit... 0x0  Reset issued by an SNMP MIB browser:  [14  2007-09-17 16:25:17 631.641  34 C] SNMP: board hard reset   Module NumberLine NumberExit CodePreliminary
  001-2019-500 Rev 0          Paragon4 – UHF, 700  & 800MHz User Manual   82 6.11.7.1.3 Other Other log entries may be warnings, faults on temporary conditions that can later be recovered, recovery from faults, or other abnormal conditions.  6.12  OOB Data (Out of Band GPS delivery) Figure 75 - Out-Of-Band Item  Description GPS Delivery Delivery Options  Drop-down box for selecting the desired format for the Local Port GPS data delivery UDP Hosts   Dynamic window expands as Hosts are added or shrinks as Hosts are deleted. (Screen capture shows one UDP Host added – displayed as #1) Add/Delete UDP Host Up to five UDP Hosts may be added:  ♦ Select the Add or the Delete option button. ♦ Enter dot decimal format address of the Host in the address field box. ♦ Enter port number in the Port field box. ♦ Click on the “Format” drop-down box and select appropriate format for the UDP Host being added or deleted. ♦ Click on Apply.    Preliminary
  001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    836.13 Remote Table  Figure 76 - Remote Table Preliminary
             001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    84   Item  Description #  Index of the displayed entry. Up to 25 entries will be displayed at a time. “Previous” and “Next” buttons will appear as necessary. RF MAC  RF MAC address of the mobile RF IP addr  RF IP address of the mobile Proxy  Indicates when the TCP Proxy has been enabled for that mobile (On/Off) Status Indicates the current state of the mobile. Most common values are: ♦ Normal – Mobile is registered to this base ♦ Handoff – Mobile is roaming to another base Reg’d  Indicates the time the mobile registered on the base Last TX  Indicates the time of last transmitted packet TX Pkts  Count of data packets sent to the mobile Tx Retrys  Count of RETRYs for packets transmitted to the mobile Tx Bytes  Count of bytes transmitted to the mobile Average Delivery Time  The average time from which an outbound IP message destined for the mobile is presented to the airlink layer until the RF acknowledgement for that message is received.  Note: The Average Outbound Delivery Time for all mobiles over a period of time is also availa-ble on the Statistics → Performance page. Last Rx  Indicates the time of the last received packet Rx Pkts  Count of data packets received from the mobile Rx Bytes  Count of bytes received from the mobile P3 RSSI dBm  RSSI (in dBm) of the last data received from the mobile. G3 RSSI dBm  RSSI (in dBm) of a recent data from the base by the mobile (This information is transmitted to the base along with the GPS report) Local upgrade revision  Number of local updates (incremented when updated locally ) Remote upgrade revision  Number of remote parameter updates (incremented when updated over the air) Last GPS Report: ♦ UTC ♦ Latitude ♦ Longitude In normal operation, indicates the last Time & Position reports recently transmitted to the base from the mobile.  Indicates “GPS report missing or not valid” when originally registered if reporting has not yet begun. Could last up to 3 – 4 minutes. Indicates “No Fix” when validly reporting and stops receiving valid information. Preliminary
             001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    856.14  Site Map and Help Site Map link and Help icon (Figure 77) features are designed to help the user navigate through the Web-Pages. They can be found on the bottom of the navigation pane. Figure 77 - Help Icon Item  Description Site Map  Click Site Map link to display a page that hierarchically lists all Web-Pages on the site and provides a short description where applicable. Help Icon  Click the Help Icon in the navigation pane to open a help text relating to the window being displayed.   Preliminary
             001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    867.  Troubleshooting and Testing  The checks described below should be done at time of installation, annual intervals, or whenever deteri-oration in performance is noted. These checks are to be done by a CalAmp field service employee, a pro-fessional installer, or an accredited radio shop technician. 7.1  Equipment Required  • In-line RF power meter in the 0.5W range for the 150 mW exciter module power output*. Consider wattmeter in the -15W range for the reflected power and in the -50W range for the forward power of the power amplifier.  *Note: The Crescend PA requires an input power level ranging from 100 to 200mW. The ex-citer module is therefore adjusted at the factory for 150mW typical.   • Radio service monitor (IFR-120B with option 03: 30 kHz IF filter or equivalent).  • Short RG-223 cable (<2ft) with N-Type male connector to connect the exciter module to the service monitor if necessary. Short RG-214 cable (<1 foot) with N-Type male connector to connect the power amplifier module to the service monitor if necessary.  • RF load 50Ω 150W. Important note: Before proceeding make sure that the service monitor has been calibrated re-cently and has warmed up for at least the time specified by its manufacturer.  Some reported frequency and deviation problems have actually been erroneous indications from service monitors that have not adequately warmed up. This is particularly likely when field ser-vice is done during winter months.  7.2  Recommended Checks   A) After an installation 1. Power-up LED Sequence 2. Transmit power output 3. Reflected power output 4. RF Link test between Paragon4 unit and mobile unit(s) (PING from a PC as per para-graph 7.4.1)   B) For annual maintenance & trouble-shooting Same checks as A) plus: 5. Carrier frequency error 6. TX Deviation 7. 12dB SINAD 8. Receiver distortion 9. Main RX and Aux. RX RSSI 10. Verify power supply connections & terminals torque settings (see paragraph 4.4.2.2) Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    87Table 8 - Checklist A (After installation) CHECKLIST A (Paragon4) Recommended Check out after Installation Step  ACTION  EXPECTED RESULTS at 25°C  MEASURE WITH  IF NOT? 1  Normal Power-up Sequence BSC2  PWR LED lights red for up to 5 second, turns amber for up to 5 seconds second,  and stays green thereafter. TX LED flashes green within 90 seconds after reset   RX LED remains OFF STATUS LED remains OFF      ETH 1 LED – if connection present – lights green. Flashes amber with activity ETH 2 LED – If connection present – lights green. Flashes amber with activity RX  POWER and LOCK LEDs must remain steady green TX POWER and LOCK LEDs must remain steady green ON LED lights red for one second, turns OFF for 10 seconds, and stays red the-reafter For steps below, refer to Radio (RF Tests)  Web Page 2  Power Amplifier Output Power Under Test Tone sec-tion select Unmodulated and  click Execute UHF: 100W (factory configurable from 50W) 700 or 800 MHz: 70 watts (factory configurable from 35W) Tolerance: +15%   -20%  Service monitor set to read power or 150W in-line wattme-ter installed as close as possible to the unit antenna connector. Verify if PA front panel LEDs are off, except PWR LED on green.  If not 1Check for bad connections, damaged coax cable, etc.  Also check power at exciter module output. Should be in the range of 100-200mW.  If OK, PA may be at fault. Contact CalAmp support. 3  Transmitter Reflected Power Under Test Tone sec-tion select Unmodulated  and  click Execute < 5% of forward power or as speci-fied by System Engineering.   15W in-line wattmeter Verify if PA front panel LEDs are  all OFF except PWR LED (green) If not, check for bad connections, damaged coax cable, etc. 4  RF Link test between Paragon4 unit(s) and mobile unit(s) (PING test as per paragraph 7.4.1)                                              1 (unless unit has been set a lower value). Note that readings less than 100 watts for UHF or 70 watts for the 700 and  800 MHz models, may be due to losses in cables used for testing.  Check also your wattmeter frequency calibration curve. Do not be too ready to condemn the transmitter or the RF feedline & antenna installation.  Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    88 Table 9 - Checklist B (General) CHECKLIST B (Paragon4) General Check out (part1 of 2) Paragon4 units are set and characterized at the factory to optimize performances.  It is not recommended to try readjusting units unless it is really required.  Misadjusting a unit may result in significant performance losses. The proposed adjustments in the "IF NOT?" column below, should be tried ONLY if system data performance degra-dation is noticed combined with out-of-tolerance items. Step  ACTION  Expected Results at 25°C MEASURE WITH  IF NOT? 1  Normal Power-up Sequence  BSC PWR LED lights red for up to 5 second, turns amber for up to 5 seconds second,  and stays green thereafter. TX LED flashes green within 90 seconds after reset   RX LED remains OFF STATUS LED remains OFF      ETH 1 LED – if connection present – lights green. Flashes amber with activity ETH 2 LED – If connection present – lights green. Flashes amber with activity RX1 and  RX2  PWR and LOCK LED must remain steady green TX  PWR LED and LOCK LED remain steady green  TX LED  lights red after 10 seconds,  and stays red thereafter For steps below, on the Radio Î Set Up Web page, press the “test” button to enable Test Tone function 2 Transmitter Output Power  From the Maintenance unit WEB “Test Tone” page,  Select Unmodulated – and  click Execute UHF: 100W (factory configurable from 50W) 700 or 800 MHz: 70 watts (factory configurable from 35W) Tolerance: +15%   -20%  Service monitor set to read power or 150W in-line wattmeter installed as close as possible to the unit antenna connector. Verify if PA front panel LEDs are off, except PWR LED on green.   If not 1Check for bad connections, damaged coax cable, etc.  Also check power at exciter module output. Should be in the range of 100-200mW.  If OK, PA may be at fault. Contact CalAmp support.                                             1 (unless unit has been set a lower value). Note that readings less than 100 watts for UHF or 70 watts for the 700 and  800 MHz models, may be due to losses in cables used for testing.  Check also your wattmeter frequency calibration curve. Do not be too ready to condemn the transmitter or the RF feedline & antenna installation.  Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    893  Transmitter  Reflected  Under Test Tone section select Unmodulated  and  click Execute < 5% of forward power or as specified by System Engi-neering.   15 W in-line wattmeter Verify if PA front panel LEDs are  all OFF ex-cept PWR LED (green) Check for bad connec-tions, damaged coax cable, etc. 4  RF Link test between Paragon4 unit and mobile unit(s) (PING test from the unit Web page as per paragraph 6.11.1 or PING from a PC as per paragraph 7.4.1) 5  Carrier Frequency Error Under Test Tone section select Unmodulated  and  click Execute < ±300 Hz  @ 25oC ambient or < ±1 ppm from –30 to +60 oC < ±0.1*) ppm  –30 to +60 oC Service monitor set to read frequency error. *)0.1 ppm requires the 10MHz refer-ence option to be present and instrument’s time gate set to 1sIf the carrier frequency error is found to be out-of-specs, contact CalAmp support. 6  TX Deviation (kHz)  Under Test Tone section  select  Modulated  and  click Execute  Carrier will be modulated with a 1 kHz tone. Refer to 7.3.1 for TX Deviation details. Tolerance is +5%, -10% for all bit rates. Service monitor set to read deviation. (IF filter set to Mid or 30 kHz position)  If the TX deviation is found to be out-of-specs, contact CalAmp support.  Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    90CHECKLIST B (Paragon4) cont’d General Check out (part 2 of 2) Step  ACTION  Expected Results at 25°C  MEASURE WITH  IF NOT? 7  12 dB SINAD (Wide band measurement method: no audio filtering) Using a 1KHz tone, set TX deviation to  ±1.5 kHz  for a 12.5KHz channel,   ±3.0 kHz  for a 25KHz channel and ±6.0 kHz  for a 50KHz channel..  Better than  -109 dBm for 12.5KHz channel, -110 dBm for25KHz channel and -108 dBm for 50 KHz channel using a 2ft RG-223 coax cable.    - Backplane corresponding to the receiver being veri-fied: J18 pin 1 for RX1 or J19 pin1 for RX2 (see Figure 425). GND pin  available at TP33 -  Service monitor  (IFR) set to SINAD -   IFR IF filter set to MID position or 30 kHz wide filter.  If the 12 dB SINAD is found to be out-of-specs, check for bad connections, damaged coax cable, etc. If not OK, contact   CalAmp support. 8  Receiver distortion  (Wide band measurement method: no audio filtering)   Set service monitor RF Gen output to –70 dBm.  Using a 1KHz tone, set TX deviation to  ±1.5 kHz  for a 12.5KHz channel,   ±3.0 kHz  for a 25KHz chan-nel and ±6.0 kHz  for a 50KHz channel.  ≤ 3 %  - Backplane corresponding to the receiver being veri-fied: J18 pin 1 for RX1 or J19 pin1 for RX2 (see Figure 4). GND pin  available at TP33 -  Service monitor (IFR) set to DISTORTION. -  IFR IF filter set to MID position or 30 kHz wide filter. If the Distortion is found to be out-of-specs, check for bad connections, damaged coax cable, etc. If not OK, contact   CalAmp support. 9  RSSI Apply to each receiver input the following RF level:  UHF,  700 & 800 MHz:   -80dBm, unmodulated. -Æ    -110dBm, unmodulated. -Æ UHF, 700 & 800 MHz:    2.75 VDC (±0.2VDC)  1.45 VDC (±0.2VDC)  BSC2 must be connected to the radio during the measurements - Backplane corresponding to the receiver being veri-fied: J18 pin 4 for RSSI1 or J19 pin 4 for RSSI2 (see Figure 4). GND pin  available at TP33 - DC Voltmeter measure-ment Refer to factory tech-nical support only if RX data performance de-gradation is noticed combined with out-of- tolerance RSSI read-ings. 10   Verify power supply connections & terminals torque settings (see paragraph 4.4.2.2)   Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    917.3  Additional test details 7.3.1 Carrier Deviations Carrier Modulation SRRC4FSK  SRRC8FSK  SRRC16FSK    Tone      Tone     Tone Network Speed (kb/s) Typical dev-iation in kHz Network Speed (kb/s)Typical dev-iation in kHz Network Speed (kb/s)Typical dev-iation in kHz (1000Hz test tone)  (1000Hz test tone)  (1000Hz test tone) Full Channel (UHF) 25 kHz bandwidth  32  ± 3.5  48  ± 4.1   64  ± 4.2        43.2  ± 4.2       Half Channel (UHF) 12.5 kHz bandwidth  16  ± 1.5   24  ± 2.1  32  ± 2.2  Wide Channel (700MHz) 50KHz bandwidth 64  ± 5.8  96  ± 6.7  128  ± 6.7 Full Channel (700MHz) 25KHz bandwidth 32  ± 2.5   48  ± 2.9  64  ± 2.9        43.2  ± 3.0       Half Channel (700MHz) 12.5KHz bandwidth 16  ± 1.3   24  ± 1.4  32  ± 1.5  Full Channel (800MHz) 25KHz Bandwidth 32  ± 2.4  48  ± 2.8  64  ± 2.8       43.2  ± 3.2       NPSPAC Channel (800MHz USA-only) 12.5KHz Bandwidth 16  ± 2.1  24  ± 2.5  32  ± 2.5 Table 10 - Carrier Deviations 7.3.2 PF Switch Nearly all test “Actions” described in tables 3 and 4 above can be done by selecting the relevant test tone via the “Radio ► Tests” page of the web interface. However, stopping the Airlink for a test is done in a different manner. It requires the use of the BSC’s front-mounted PF key rocker switch (detailed PF operation in the next paragraph). The PF switch can also be used as an alter-nate way of selecting Test Tones or if a web connection is unavailable. 7.3.2.1  Stopping the Airlink and Alternate Test Tone Selection Method Located on the BSC module, the PF key is a horizontally mounted rocker switch with a center detent and spring-loaded positions “1” and “2”. Pressing the switch to posi-tion “1” causes the “Status” LED to blink green once only followed by amber blinks at one-second intervals as long as it is held pressed. Pressing the switch to position “2” is used to select test tones as shown in Table 11 below. Figure 78 - PF Switch Rocker Detail (one side pressed)Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    92• If PF is pressed to position “1” for approximately four seconds (visually count the amber blinks) and released, it brings the Airlink down, PTT is released, no data traffic is sche-duled, and CWID is suppressed. The Airlink will remain down for a maximum of one hour and automatically come back up, unless PF is pressed to position “1” once more for four seconds to force toggle the Airlink to “up” status.  • If PF is pressed to position “1” for approximately one amber blink, PF operation goes in-to “test mode” where “position 2” is monitored and each successive pressing of position “2” results in a different test tone selection as detailed in the table below.  • If PF is pressed to position “1” while a test is in progress, PF “test mode” operation is cancelled. Note:   If PF is not in “monitor mode” pressing to position “2” has no effect. Table 11 - Test Tones Generation 20-Second Test Tones - PF key generated  For a MODULATED test tone: Press PF to “1” for approximately 1 amber blink and release. Immediately press PF to “2” one time. Test tone starts. To cancel test tone, press PF to “1” and release. For an UNMODULATED test tone: Press PF to “1” for approximately 1 amber blink and release. Immediately press PF to “2” two times. Test tone starts. To cancel test tone, press PF to “1” and release. For a SQUARE WAVE test tone: Press PF to “1” for approximately 1 amber blink and release. Immediately press PF to “2” three times. Test tone starts. To cancel test tone, press PF to “1” and release. For a RANDOM DATA test tone: Press PF to “1” for approximately 1 amber blink and release. Immediately press PF to “2” four times. Test tone starts. To cancel test tone, press PF to “1” and release. Each pressing at position “2” must be made within one second. E.g.: For Unmodulated, press twice within 2 seconds, for Random Data, press four times within 4 seconds.  Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    937.4 Windows/Unix Tools 7.4.1 Network Connectivity • PING (DOS/WINDOWS) The ping command determines whether a specific IP address is accessible. It works by sending a packet to the specified address and waiting for a reply. It is useful for troubleshooting “end-to-end” reachability, network connectivity, and network laten-cy.  The ping test is also convenient to verify more specifically the RF link between a mobile and a known base station  EXAMPLE: ping 192.168.204.1 –w 3000 displays the response with turn around time in milliseconds. • TRACERT (WINDOWS) The tracert command is used to visually see a network packet being sent and re-ceived and the amount of hops required for that packet to get to its destination.  Note: Users with MS-Windows 2000 or XP who need additional information on net-work latency and network loss may also use the pathping command. EXAMPLE tracert www.yahoo.com at the command prompt displays the intermediate routers between local host to the www.yahoo.com site. 7.4.2 Configuration Information • IPCONFIG Ipconfig is a DOS utility which can be used from Command Prompt or a Com-mand Prompt shell to display the network settings currently assigned and given by a network. This command can be utilized to verify a network connection as well as to verify network settings.  EXAMPLE ipconfig/all at the command prompt displays the Ethernet MAC address, IP address, IP netmask, default IP gateway, DNS server… information. • ARP  View and update the system ARP table The Address Resolution Protocol (ARP) is used with the IP protocol for mapping a 32-bit Internet Protocol address to a MAC address that is recognized in the local net-work specified in RFC 826. Once recognized the server or networking device returns a response containing the required address.  Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    94 EXAMPLE arp-a displays all entries in the ARP cache. Useful in manipulating ARP caches. • ROUTE  View and update the system routing table The function and syntax of the Windows ROUTE command is similar to the UNIX or Linux route command. Use the command to manually configure the routes in the routing table.  EXAMPLE  route ? displays help route print displays the routing table  7.4.3 Statistics Information • NETSTAT (WINS & UNIX)  The netstat command symbolically displays the contents of various network-related data structures, i.e. IP, TCP UDP …  EXAMPLE  netstat ?   displays help netstat -a   display TCP and UDP connections and listening ports informa-tion  For further information on TCP/IP troubleshooting, please visit: http://www.windowsitlibrary.com/Content/466/14/1.html 7.5  BSC Firmware Upgrading The Paragon4 radiomodem firmware is field-upgradable using the unit’s Ethernet port. The process involves connecting to the IP address of the base from a host PC and transferring the firmware files via an FTP program.  7.5.1 Procedure 1. Using a file decompression program, such as WinZIP™ or WinXP’s right-click & select the “Expand to…” option, expand the contents of the firmware upgrade package to a di-rectory of your choice on the host PC. Warning: Be aware that base and mobile’s firmware archives are often distributed at the same time. Files intended for the Paragon4 radiomodem are labeled in the form                        Para-gon4_edba_vx.x_Rx.xx.zip. Be careful not to transfer firmware into the wrong unit!  2. Using an FTP client program of your choice, establish a connection to the base IP ad-dress. 3. Transfer all the files in the upgrade package. Occasionally, long pauses, on the order of 30 to 45 seconds, are possible when storing the file in the unit’s flash file system. Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    954. Once the file transfer is complete, cycle the base power and allow the unit to boot. The unit should return to the state it was in when the update was started.  Note: After resetting, the PWR LED remaining lit steady amber or red indicates the FTP trans-fer was not successful or that the firmware is corrupt. Please contact Dataradio system engineering for assistance. Figure 79 - Sample FTP program 5. Verify the integrity of the newly transferred files.  a) Connect to the base’s IP address using an Internet browser  b) Enter the user name and password (in the usual manner) and allow the Welcome page to load.  c) In the left pane, click on Unit Status. The Unit Identification and Status pane should display the newly upgraded firmware in its Banner (should correspond to the upgrade pack-age version) and the H/W Status should also show Ok. d) In the left pane, click on Maintenance, then on Package Control. Wait a few moments for the results to display.  7.5.1.1  File Integrity Failure If the message in the result screen points out that file(s) failed the integrity check, retry the FTP transfer for the failed files(s) again.  If the problem persists, please have the Package Control result screen indications handy and contact Dataradio system engineering for assistance.      Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    968. Specifications  GENERAL UHF                    700MHz                                       800MHz Frequency Range (MHz)    FCC =  406.1 - 512 Rx/Tx        IC =  406.1 - 430 Rx/Tx      IC =  450 - 470 Rx/Tx FCC = 757 - 758,  763 - 775 Tx   FCC = 787 - 788,  793 - 805  Rx IC  =  764  - 776 Tx  IC  =  794  - 806 Rx FCC = 851 -  869 Tx   FCC = 806 -  824 Rx IC = 851 - 869 Tx    IC = 806 -  824 Rx FCC Part 90 & 27 / IC RSS-119 Channel Spacing  12.5 / 25 KHz  12.5 / 25  / 50 KHz  NPSPAC / 25 KHz Mode of Operation  Full Duplex, 100% duty cycle Cabinet Size  22.06” W x 75.82” H (without leveling feet) x 27.06” D RF/Modem Assembly Size  (Rackmount) 19.0” W x 8.75” H x 12.5” D + 2.0” connector allowance AC/DC Power Supply Assembly Size   (Rackmount): 19.0” W x 3.5”H x 16.5” D Power Amplifier Assembly Size  (Rackmount): 19.0” W x 7”H x 6” D Frequency Stability  1.0 ppm (-30°C to +60°C) Supply Voltage   120 VAC / 6A max, 60 Hz  to 13.8 VDC or 13.8 VDC nominal, negative ground (12.6 to 14.6 VDC range) Circuit protection  Radio backplane: Main fuse (F1) 10A Blade fuse & crowbar diodes for reverse polarity protection Power Amplifier: Fuse protected, overvoltage protected & current limited  via AC/DC power supply or PA power cable with in-line 30A fuse for DC power supply application  RX Current Consumption @ 13.8 VDC  3.0A max. (Two receivers with speaker monitoring) TX Current Consumption @ 13.8 VDC 24A DC typical @ 25C, 450 MHz & 100W (26.5A DC max for -30 to +60C, 403-512MHz & 100W) 22A DC typical @ 25C, 770MHz & 70W    (25A DC max for -30 to +60C, 757-775MHz & 70W 23A DC typical @ 25C, 860MHz & 70W    (26A DC max for -30 to +60C, 851-869MHz & 70W Operating Temperature Range -30°C to +60°C  (deleted power supply, catalog number with 0 in second to last digit) -30°C to +50°C  (with standard Heavy Duty Power Supply, catalog number with 2 in second to last digit)   Modem / Network  User Interface  •  Dual Ethernet RJ45 Auto MDIX 10-100/T with LED status indicators •  Dual RS-232 DB-9F Serial Ports configured as Terminal Servers •  USB Port (future use) Addressability  Native TCP/IP and built-in router Data Encryption AES 128-bit Protocols  •  Dataradio Proprietary E-DBA with OOB AAVL support •  Ethernet IEEE 802.3, (ICMP, IGMP, TCP, UDP) •  IP Fragmentation, Address Resolution Protocol (ARP) •  IP directed broadcast, IP limited broadcast, IP multicast relay •  DHCP client and server •  Network Address Translation (NAT), Dynamic Routing (RIPv2) Data rates  12.5 kHz ch.:   25  kHz ch.:  50 kHz ch.:   NPSPAC ch.: 32 kbps 24 kbps  16 kbps 64 kbps 48 kbps 43.2kbps 32 Kbps 128 kbps 96 kbps 64 Kbps 32 kbps 24 kbps  16 kbps   Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    97Radio UHF   700MHz  800MHz Data rates (kbps) 25 kHz Channel 12.5 kHz Channel 50 kHz Channel 25 kHz Channel 12.5 kHz Channel 25 KHz Channels  NPSPAC Channels Receiver Sensitivity (For 1% Packet Error Rate (PER) with Parallel Decode at carrier frequency)       -94              128       -100              96 -98   -106 -95   -95   64 -104      -101   -101   48 -108     -105   -105   43.2 -110 -100     -107  -98  -107 -103 32    -106        -103     -109  24    -109        -110     -115  16 Selectivity   >85 dB  >67 dB  >87 dB  >85 dB  >67 dB  >85 dB  >85 dB   Spurious Response Rejec-tion  100 dB (Typical) Intermodulation Rejection >83 dB   >80 dB   >83 dB  >83 dB   >80 dB   >83 dB   >83 dB   Receiver Frequency range  406.1 – 512 MHz  787 - 788,  793 - 805 MHz  FCC,     794 - 806 MHz  IC  806 – 824 MHz Transmitter Frequency range  406.1 – 512 MHz  757 - 758,  763 -775 MHz  FCC,      764 - 776 MHz  IC  851 – 869 MHz Power Output (field service adjustable)   (50-100W)   (35-70W)  (35-70W) Spurious Emissions:- transmit -standby <-36 dBm to 1 GHz,  <-30 dBm to  3.2GHz                                       <-57 dBm to 1 GHz,  <-47 dBm to 3.2GHz    VSWR Stability  > 5:1 mismatch    FCC / IC CERTIFICATIONS  FCC (Part 90 or 27)  IC (DOC, RSS119)  UHF 406.1 - 512 MHz  CWWUHFP10XXUL1 (PA, 100W, 403-470MHz) TBD (PA, 100W, 450-512MHz)    EOTBDP4-EXCT403 (Exciter, 0.4W, 403-477MHz) EOTBDP4-EXCT438 (Exciter, 0.4W, 438-512MHz) 406.1 - 430 MHz   450 -  470MHz  7291A-UHFP10XXUL1 (PA, 100W, 403-470MHz)  731A-BDP4EXCT403 (Exciter, 0.4W, 403-477 MHz) 700 MHz 757-758 MHz  TBD (PA, 80W)    TBD (Exciter, 0.4W)    769-775 MHz  EOTBDP3-CRE700 (PA, 70W, 764-776MHz)    TDB (Exciter, 0.4W)     764 - 776 MHz     773-BDP3CRE7 (70W PA)    TBD (0.4W Exciter) 800 MHz  851 - 869 MHz  EOTBDP3-CRE800 (70W PA)  773A-BDP3CRE8 (70W PA)   EOTBDD4-EXT8 (0.4W Exciter)  773A-BDD4-EXT8 (0.4W Exciter)    Preliminary
            001-2019-500 Rev 0    Paragon4 – UHF, 700  & 800MHz User Manual    98 EMISSION DESIGNATORS Bit rate  Baud rate  Modulation  UHF  700MHz  800MHz 128000 32000 SRRC16FSK  -  27K0F1D (pending)  - 96000 32000 SRRC8FSK  -  27K0F1D (pending)  - 64000 32000 SRRC4FSK  -  27K0F1D (pending)  - 64000 16000 SRRC16FSK  16K1F1D  (C) 14K0F1D (pending)  13K7F1D (G) 48000  16000  SRRC8FSK  15K8F1D (C)  14K0F1D (pending)  13K7F1D (G) 43200  14400  SRRC8FSK  15K8F1D (C)  14K8F1D (pending)  13K4F1D (G) 32000  16000  SRRC4FSK  16K1F1D (C)  14K0F1D (pending)  13K4F1D (G) 32000  8000  SRRC16FSK  8K30F1D (D)  7K20F1D (pending)  10K0F1D (H)   8K2F1D (D) 24000  8000  SRRC8FSK  8K30F1D (D)  7K20F1D (pending)  10K0F1D (H) 8K2F1D (D) 16000  8000  SRRC4FSK  7K80F1D (D)  7K20F1D (pending)  10K0F1D (H)  8K2F1D (D)  [1] FCC/IC mask G (800MHz, 25kHz ch.) [2] FCC mask H (800MHz, NPSPAC ch.) [3] IC mask D (800MHz, 12.5kHz ch.) [4] FCC/IC mask C (UHF,  25kHz ch.) [5] FCC/IC mask D (UHF, 12.5kHz ch.)              Preliminary

Navigation menu