Continental Automotive 37924100 Remote Transceiver for Car Access User Manual Functional description

Continental Automotive GmbH Remote Transceiver for Car Access Functional description

Contents

User manual

Download: Continental Automotive 37924100 Remote Transceiver for Car Access User Manual Functional description
Mirror Download [FCC.gov]Continental Automotive 37924100 Remote Transceiver for Car Access User Manual Functional description
Document ID1897095
Application IDER0/XAUVlqF9ef+zZ0O7og==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize135.15kB (1689377 bits)
Date Submitted2013-02-08 00:00:00
Date Available2013-02-08 00:00:00
Creation Date2012-12-05 07:54:34
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2012-12-10 13:06:14
Document TitleFunctional description / user manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Kolar Dagmar;+49 941 202-6699

Continental AG
I BS PG3 CFRF WM
User Manual
of the
Continental
Radio Frequency Bidirectional Key Fob
Type
Acura Bidir Fob MY13.5
A2C37924100
Continental AG
I BS PG3 CFRF WM
GENERAL DESCRIPTION OF THE RF TRANSMITTER
The Acura Bidir Fob is a bidirectional RF key designed to provide remote
engine start with feedback, remote keyless entry, passive entry, passive
engine start, and immobilization functionality.
The Acura Bidir Fob has a housing, which may have variants in the pictogram
“Trunk”, alternatively “Power-Tail-Gate”(PTG):
Continental AG
Feedback on Bidir Fob
There exist 3 LEDs for all feedback, at the top of the fob,
out of the way of the hand that is holding it.
LEFT LED Color : AMBER
Function: To show RF communication, or that 2-way
communication is taking place.
Example: LEFT/AMBER LED flashes 1x in response to a
button being pressed when the RF command is sent,
and/or it can flash while communicating with the vehicle, or
waiting for response (example: while engine is cranking) .
Also this LED will blink in response to SMART entry
authentication.
For other cases, generally the Amber LED should operate
in a manner that is respective of the "Base SMART key".
CENTER LED Color: GREEN.
Function: Used to show positive feedback for a given
command.
Example: CENTER/GREEN LED is on for 1 second, to
provide status feedback for a given operation. It means:
Doors were locked, or engine was started, or engine is ON.
RIGHT LED Color: RED.
Function: Used to show negative feedback for a given
command.
There are 2 modes.
1. Out of range. In this case the red LED blinks distinctly
3 times,
Example: 3 times in 1 second. It means the fob could
not get acknowledgement from the car for 2-way
communication, or the vehicle battery is dead and
cannot respond.
2. Cannot Lock or Engine not running. In this case the red
LED is on for 1 second.
I BS PG3 CFRF WM
Continental AG
I BS PG3 CFRF WM
POWER MANAGEMENT
The Power Supply comprises a coin cell battery CR2032, filter capacitors,
diodes, and FETs, that provides power to the microcontroller, the powermanagement with charger and the RF circuit. A rechargeable battery (accu) of
the type LiFePO4 is included to supply higher currents in case of long range
transmission.
The accu type LiFePO4 is of the class Li-Ion cell, but with a safe chemistry.
There exists a certificate, that it is not dangerous / harmfull in the sense of
UN3480 and "Transportation without Class 9 is allowed".
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
NOTE:
Changes or modifications not expressly approved by the manufacturer could
void the user's authority to operate the equipment.
Continental AG
I BS PG3 CFRF WM
6. TESTMODE FUNCTION
The testmode function is only available by EEPROM settings, which could
provided only in specially programmed samples for measuring purpose.
ENG.START
LOCK
UNLOCK
TRUNK
PANIC
no function
TX CW Modes
TX Modulated Modes
RX Modes
another inner function
amber LED
green LED
Button description
red LED
Button functions
By pressing the specified button, the previously defined channels are
revolving.
The Lock button revolves the 8 Channels CW-mode till TX-off
TX-LR-CH2,
CW-f_low2
TX-LR-CH2,
CW-f_high2
TX-LR-CH1,
CW-f_high2
switch to
accu-supply,
TX-LR-CH1,
CW-f_low2
3x red
LED
flash1,
TX OFF
all LEDs
OFF
switch to
bat-supply,
TX ON,
TX-SR-CH1,
CW-f_low
TX-SR-CH1,
CW-f_high
TX-SR-CH2,
CW-f_high
TX-SR-CH2,
CW-f_low
Notes:
: 3x red flash: 200ms on, 200ms off, 200ms on, 200ms off, 200ms on, off
: ATIC134 Lite option only
Continental AG
I BS PG3 CFRF WM
The Unock button revolves the 4 modulated channels till TX-off
TX-LR-CH2,
mod.2
3x red LED
flash1,
TX OFF
all LEDs
OFF
switch to batsupply, TX
ON, TX-SRCH1, mod.
TX-SR-CH2,
mod.
switch to accusupply, TXLR-CH1,
mod. 2
Notes:
: 3x red flash: 200ms on, 200ms off, 200ms on, 200ms off, 200ms on, off
: ATIC134 Lite, test signal data content: zeros
The Trunk button revolves the 2 Receive-Channels till RX-off
1x amber
LED flash
4x
green&red
LED flash
RX-LR-CH2
1x amber
LED flash
3x
green&red
LED flash,
RX-LR-CH1
3x red LED
flash1,
RX OFF
all LEDs
OFF
switch to
bat-supply,
RX ON, 1x
green&red
LED flash,
RX-SR-CH1
2x
green&red
LED flash,
RX-SR-CH2
Notes:
: 3x red flash: 200ms on, 200ms off, 200ms on, 200ms off, 200ms on, off
1x amber
LED flash
1x amber
LED flash
Continental AG
I BS PG3 CFRF WM
7. LABEL DESIGN
CANADA
IC:7812D-37924100
USA
FCC ID:KR537924100
The print is visible after opening the
Fob like for battery change.
How to open the Bidir Fob for Battery Change
Take a coin (best fit: 2€, or a Quarter Dollar), press it into the groove and turn
it against the metallic eyelet counterclockwise.
For closing follow the instruction:

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Kolar Dagmar;+49 941 202-6699
Create Date                     : 2012:12:05 07:54:34+01:00
Modify Date                     : 2012:12:10 13:06:14+01:00
Has XFA                         : No
Language                        : de-DE
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : Kolar Dagmar;+49 941 202-6699
Title                           : Functional description / user manual
Creator Tool                    : Microsoft® Office Word 2007
Metadata Date                   : 2012:12:10 13:06:14+01:00
Producer                        : Microsoft® Office Word 2007
Document ID                     : uuid:037af108-a59e-4dc4-81e9-fbb285080d3a
Instance ID                     : uuid:ea6256af-7119-40ff-912a-da0111118c17
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KR537924100

Navigation menu