DCH-Z110/Z120                            The sensor DCH-Z110/Z120 have PIR or door/window integrated with,temperature   and   illumination,  which   are  3  sensors   function   in   one,based on Z-WaveTM technology.It is the Z-WaveTM plus product, it supports  the security, OTA... Thosenewest  features of  the  Z-WaveTM  technology.  Z-WaveTM  is  a  wirelesscommunication protocol designed for home automation, specifically toremotely   control   applications   in   residential   and   light   commercialenvironments. The technology uses a low-power RF radio embedded orretrofitted into home electronics devices and systems, such as lighting,home access control, entertainment systems and household appliances.This product can be included and operated in any Z-WaveTM  networkwith other Z-WaveTM certified devices from other manufacturers and/orother applications.  All non-battery operated nodes within the networkwill act as repeaters regardless of vendor to increase reliability of thenetwork.The device adopt the Z-WaveTM  500 series chip, when your Z-WaveTMnetwork   system   is   all   made   by   Z-WaveTM  500   series   devices.   Thenetwork system will have the advantages as below.•Concurrent multi-channel support reduces external interference.•Better RF range, improve about 10 meters in indoor.•Support 100 Kbps transmit speed, speed up communication.Function Compare DCH-Z110/DCH-Z120PIR Door/Window Temperature IlluminationDCH-Z110 V V VDCH-Z120 V V VAdd to/Remove from Z-WaveTM NetworkThere  are  two  tamper  keys  in  the  device,  one is  in  the  back  side,another is in the front side.  Both of them  can add, remove, reset orassociation from Z-WaveTM network.In the first time, add the device into the Z-WaveTM network.  First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.1
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”.  Excluding a node ID allocated by Z-WaveTM  Controller means “Remove” or “Exclusion”.Function DescriptionAdd1.Have Z-WaveTM Controller entered inclusion mode.2.Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.3.After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.Remove1.Have Z-WaveTM Controller entered exclusion mode.2.Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.Node ID has been excluded.ResetNotice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1.Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.2.After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful,the LED will light ON one second. Otherwise, the LED will flash once.3.IDs are excluded and all settings will reset to factory default.Association 1.Have Z-WaveTM Controller entered association mode.2.Pressing tamper key three times within 1.5 seconds to enter the association mode.Note: The device support 2 groups. The group 1 is for receiving the report message, like triggered event, temperature, illumination etc. The group 2 is for light control, the device will send the “Basic Set” command to this group. And each group support 8 nodes maximum.•Failed or success in add/remove the node ID can be viewed from Z-WaveTM Controller.Notice 1: Always RESET a Z-WaveTM device before trying to add it to a Z-WaveTM networkNotice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout after 30 seconds. You can press the tamper key 3 times to abort the NWI mode.Z-WaveTM NotificationAfter the device adding to the network, it will wake-up once per day indefault. When it wake-up it will broadcast the “Wake Up Notification”message   to   the   network,   and   wake-up   10   seconds   for   receive  thesetting commands.The wake-up interval minimum setting is 30 minutes, and maximumsetting is 120 hours. And the interval step is 30 minutes.If the user want to wake-up the device immediately, please remove thefront cover, and press the tamper key once. The device will wake-up 10seconds.Z-WaveTM Message ReportWhen  the  PIR  motion  triggered  or   the  door/windows  triggered,  thedevice will report the trigger event and also report the battery status,temperature and illumination level.In default  the  device  will using  Notification  Report to  represent  thetrigger event, it can be changed to Sensor Binary Report by setting theconfiguration NO. 7 Bit4 to 1.2
* Motion Report:When the PIR motion detected, the device will unsolicited to send thereport to the nodes in the group 1.Notification Report (V4)Notification Type: Home Security (0x07)Event: Motion Detection, Unknown Location (0x08)Sensor Binary Report (V2)Sensor Type: Motion (0x0C)Sensor Value: 0xFF* Door/Window Report:When the door/window state changed, the device will unsolicited tosend the report to the nodes in the group 1.Notification Report (V4)Notification Type: Access Control (0x06)Event: Door/Window is open (0x16)          Door/Window is closed (0x17)Sensor Binary Report (V2)Sensor Type: Door/Window (0x0A)Sensor Value: 0x00 is closed, 0xFF is opened.* Tamper Report:Both the 2 tamper keys are pressed over 5 seconds. The device willinto the alarm state. In that state, if any one of the tamper keys bereleased, the device will unsolicited to send the report to the nodes inthe group 1.Notification Report (V4)Notification Type: Home Security (0x07)Event: Tampering. Product covering removed (0x03)Sensor Binary Report (V2)Sensor Type: Tamper (0x08)Sensor Value: 0xFF* Temperature Report:When the PIR motion detected or the door/window state changed, thedevice will  unsolicited to  send the  “Sensor Multilevel  Report”  to thenodes in the group 1.Sensor Type: Temperature (0x01)Note: To disable this functionality by setting the configuration N0.5 bit5to 1.*** Temperature differential report ***This function default is enabled, to disable this function by setting theconfiguration NO.21 to 0.In the default, when the temperature is changed to plus or minus onedegree   Fahrenheit   (0.56   degree   Celsius),   the   device   will   reporttemperature information to the nodes in the group 1.The device will measure the temperature in every one minute. And ifthe temperature is over 140 degree Fahrenheit (60 degree Celsius), thedevice will always report in each measurement.Caution 1: Enable this functionality, it will cause the PIR Motion to disable detection when the temperature measurement. In other words,The PIR motion will blind one second in every one minute.* Illumination Report:When the PIR motion detected or the door/window state changed, thedevice will  unsolicited to  send the  “Sensor Multilevel  Report”  to thenodes in the group 1.Sensor Type: Luminance (0x03)Note:  To  disable   this  functionality  by  setting  the   configuration   N0.5bit4 to 1.*** Illumination differential report ***3
Download:
Mirror Download [FCC.gov]
Document ID2434263
Application IDi79Ur1CLRYf6JTrkEC7p+A==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize61.36kB (767034 bits)
Date Submitted2014-11-03 00:00:00
Date Available2014-11-03 00:00:00
Creation Date2014-09-01 17:47:42
Producing SoftwareLibreOffice 4.3
Document Lastmod2014-10-29 15:07:04
Document TitleUser Manual
Document CreatorWriter
Document Author: Miles Lee
FCC ID Filing: KA2CHZ120A1

Navigation menu