DCH-122 PIR Motion Sensor                        The   DCH-122   has   PIR   motion   sensor  function   in   one,   based   on  Z-WaveTM technology.It   is   the  Z-WaveTM  plus   product,   it   support   the   security,   ...   Thosenewest features of the  Z-WaveTM  technology.  Z-WaveTM  is a wirelesscommunication protocol designed for home automation, specifically toremotely   control   applications   in   residential   and   light   commercialenvironments. The technology uses a low-power RF radio embedded orretrofitted into home electronics devices and systems, such as lighting,home access control, entertainment systems and household appliances.This product can be included and operated in any Z-WaveTM  networkwith other Z-WaveTM certified devices from other manufacturers and/orother applications.  All non-battery operated nodes within the networkwill act as repeaters regardless of vendor to increase reliability of thenetwork. The device adopt the Z-WaveTM  500 series chip, when your Z-WaveTMnetwork   system   is   all   made   by   Z-WaveTM  500   series   devices.   Thenetwork system will have the advantages as below.•Concurrent multi-channel support reduces external interference.•Better RF range, improve about 10 meters in indoor.•Support 100 Kbps transmit speed, speed up communication.Add to/Remove from Z-WaveTM NetworkThere  are   two  tamper   keys   in  the   device,  one   is  in  the   back  side,another is in the front side.  Both of them  can add, remove, reset orassociation from Z-WaveTM network.In the first time, add the device into the Z-WaveTM network.  First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”.  Excluding a node ID allocated by Z-WaveTM  Controller means “Remove” or “Exclusion”.Function DescriptionAdd1. Have Z-WaveTM Controller entered inclusion mode.2. Pressing tamper key three times within 1.5 secondsto enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.1
Remove1. Have Z-WaveTM Controller entered exclusion mode.2. Pressing tamper key three times within 1.5 secondsto enter the exclusion mode.Node ID has been excluded.ResetNotice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.Association1. Have Z-WaveTM Controller entered association mode.2. Pressing tamper key three times within 1.5 secondsto enter the association mode.Note: The device support 2 groups. The group 1 is for receiving the report message, like triggered event, temperature, illumination etc. The group 2 is for light control, the device will send the “Basic Set” command to this group. And each group support 8 nodes maximum.•Failed or success in add/remove the node ID can be viewed from Z-WaveTM Controller.Notice 1: Always RESET a Z-WaveTM device before trying to add it to aZ-WaveTM network Notice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout after 30 seconds. You can press the tamper key 3 times to abort the NWI mode.Z-WaveTM NotificationAfter the device adding to the network, it will wake-up once per day indefault. When it wake-up it will broadcast the “Wake Up Notification”message   to   the   network,   and   wake-up   10   seconds   for   receive   thesetting commands.The wake-up interval minimum setting is 30 minutes, and maximumsetting is 120 hours. And the interval step is 30 minutes.If the user want to wake-up the device immediately, please remove thefront cover, and press the tamper key once. The device will wake-up 10seconds.Z-WaveTM Message ReportWhen the PIR motion triggered , the device will report the trigger eventand also report the battery status, temperature and illumination level.In  default  the  device  will  using  Notification  Report  to  represent  thetrigger event, it can be changed to Sensor Binary Report by setting theconfiguration NO. 7 Bit4 to 1.* Motion Report:When the PIR motion detected, the device will unsolicited to send thereport to the nodes in the group 1.Notification Report (V4)Notification Type: Home Security (0x07)Event: Motion Detection, Unknown Location (0x08)Sensor Binary Report (V2)Sensor Type: Motion (0x0C)Sensor Value: 0xFF2
* Tamper Report:Both the 2 tamper keys are pressed over 5 seconds. The device willinto the alarm state. In that state, if any one of the tamper keys bereleased, the device will unsolicited to send the report to the nodes inthe group 1.Notification Report (V4)Notification Type: Home Security (0x07)Event: Tampering. Product covering removed (0x03)Sensor Binary Report (V2)Sensor Type: Tamper (0x08)Sensor Value: 0xFF* Temperature Report:When the PIR motion detected tate changed, the device will unsolicitedto send the “Sensor Multilevel Report” to the nodes in the group 1.Caution 1: Enable this functionality, it will cause the PIR Motion to disable detection when the temperature measurement. In other words,The PIR motion will blind one second in every one minute. * Timing Report:Beside   the   event   triggered   could   report   message,   the   device   alsosupport the timing unsolicited report of the status.•Battery level report: Every 6 hours report once in default.It could be changed by setting the configuration NO. 10.•Low battery report: When the battery level is too low, every 30minutes will report once.Notice:  The configuration NO. 10, 11, 12 and 13 could be setting tozero to disable the auto report.  And the configuration NO. 20 couldchange the tick interval, the default value is 30, if setting to 1, thatmeans the minimum auto report interval will be one minute. And pleasenotice if setting this value to zero, that means disable all of the timingreport except the low battery detection.Power Up Procedure* Battery Power CheckWhen the device power up, the device will detect the power level of thebattery immediately. If the power level is too low, the LED will continueflash about 5 seconds. Please change another new battery.* PIR Warm UpWhen   the   device   power   on,   the   PIR   need   to   warm   up   before   theoperation. The warm up time  about 1 minute, the LED will flash inevery 2 seconds. After finish the procedure the LED will light ON threetimes.* NWIWhen the device power on, the device will check is it already adding tothe network? If doesn't, it will auto start the NWI mode. The LED willflash in every second and continue 30 seconds. Until timeout or thedevice successful to inclusion by controller. The use can presses thetamper key 3 times to abort the NWI mode.* WakeWhen the device power on, the device will wake about 20 seconds. Inthis duration, the controller can communicate with the device. Normallythe device is always sleeping to save the battery energy.Security NetworkThe device  support  the  security  function.  When  the  device includedwith a security controller, the device will auto switch to the securitymode. In the security mode, the follow commands need using Security3
Download:
Mirror Download [FCC.gov]
Document ID3089001
Application IDdyjynWlqLW9bw6o9ZIs0sg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.15kB (176870 bits)
Date Submitted2016-08-05 00:00:00
Date Available2016-08-25 00:00:00
Creation Date2016-06-22 15:41:42
Producing SoftwareLibreOffice 5.0
Document Lastmod0000-00-00 00:00:00
Document TitleUsers Manual
Document CreatorWriter
FCC ID Filing: KA2CHZ122A1