Dacor IVS2 User Manual VENT Manuals And Guides 1102309L

User Manual: Dacor IVS2 IVS2 DACOR VENT - Manuals and Guides View the owners manual for your DACOR VENT #IVS2. Home:Kitchen Appliance Parts:Dacor Parts:Dacor VENT Manual

Open the PDF directly: View PDF PDF.
Page Count: 11

Installation
Integrated Ventilation System
For use with models: IVS1, IVSR1, IVS2, IVSR2
Instructions
Part No. 65278 Rev. H
Important Safety Instructions .......................................... 1
Important Information About Safety Instructions .............. 1
General Safety Precautions ............................................. 2
Product Specifications ..................................................... 3
General Specifications ..................................................... 3
Product Dimensions ......................................................... 3
Installation Requirements ................................................. 4
Electrical Requirements ................................................... 4
Planning the Duct Work ................................................... 4
Installation Instructions .................................................... 6
Installing the IVS .............................................................. 6
Installing the Duct Work ................................................... 6
Electrical Connection ....................................................... 6
Verifying Proper Operation ............................................... 7
Installation Checklist ........................................................ 7
Wiring Diagrams ............................................................... 8
Important
Installer: In the interest of safety and to minimize problems, read these installation instructions completely and
carefully before you begin the installation process. Leave these installation instructions with the customer.
Customer: Keep these installation instructions for future reference and the local electrical inspector's use.
If You Need Help...
If you have questions or problems with installation, contact
your Dacor ®dealer or the Dacor Customer Service Team.
For repairs to Dacor appliances under warranty call the
Dacor Distinctive Service line. Whenever you call, have the
model and serial number of the appliance ready. The model
and serial number are printed on the product data label on
the unit.
Dacor Customer Service
Phone: (800) 793-0093 (U.S.A. and Canada)
Monday -- Friday 6:00 A.M.to 5:00 P.M.Pacific Time
Web site: www.Dacor.com
Dacor Distinctive Service (repairs under warranty only)
Phone: (877) 337-3226 (U.S.A. and Canada)
Monday -- Friday 6:00 A.M.to 4:00 P.M.Pacific Time
All specifications subject to change without notice. Dacor assumes no liability for changes to specifications.
© 2007 Dacor, all rights reserved.
Important Information About
Safety Instructions
The Important Safety Instructions and warnings in
these instructions are not meant to cover all possible
problems and conditions that can occur. Use common
sense and caution when installing, maintaining or
operating this or any other appliance.
Always contact the Dacor Customer Service Team
about problems and conditions that you do not
understand.
Safety Symbols and Labels
Immediate hazards that WILL result in severe personal
injury or death.
Hazards or unsafe practices that COULD result in severe
personal injury or death.
Hazards or unsafe practices that COULD result in minor
personal injury or property damage.
To avoid the possibility of explosion or fire, do not store or use combustible, flammable or explosive vapors and liquids
(such as gasoline) inside or in the vicinity of this or any other appliance. Also keep items that could explode, such as
aerosol cans away from cooktop burners, ovens and range hoods. Do not store flammable or explosive materials in
adjacent cabinets or areas.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a)
b)
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the service panel.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a)
b)
c)
d)
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards
such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage,
personal injury or death.
READ AND SAVE THESE INSTRUCTIONS
_r 1
General Safety Precautions
To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety
precautions, including the following:
Do not install or operate this appliance if it has been damaged, dropped, has damaged electrical wires or is not
working properly. If the product is damaged when received, immediately contact the dealer or builder.
This appliance must be installed and grounded by a qualified installer according to these installation instructions.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
Install or locate this appliance only in accordance with these installation instructions and the requirements specified
by the manufacturer of the cooktop or range. Improper installation, adjustment, alteration, service or maintenance
can cause serious personal injury or property damage.
The customer should not install, repair or replace any part of this appliance unless specifically recommended in
the literature accompanying it. A qualified service technician should perform all other service. Contact the nearest
Dacor authorized service representative at (800) 793-0093, or at www.Dacor.com for examination, repair or
adjustment.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
Keep all packaging materials away from children. Plastic bags can cause suffocation.
The installer must show the customer the location of the fuse box or circuit breaker panel so that the customer
knows where and how to turn the power off.
Read the use and care manual completely before using the appliance. Clean the appliance only as instructed in
the use and care manual. Use only the cleaners specified.
Do not tamper with the controls.
Never allow the filter(s) to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins,
to be sucked into the appliance.
Clean the filter(s) and all grease-laden surfaces often to prevent grease fires and maintain performance.
If the cooktop and range hood are near a window, use an appropriate window treatment. Avoid long drapes or
other window coverings that could blow over the cooktop and ventilation system, resulting in a fire hazard.
Always run the fan(s) whenever the cooktop is operating.
Never leave the range or cooktop unattended when a burner (or element) is in use. Boil-overs and greasy spills
may smoke and/or ignite.
Do not leave children alone or unattended in the area where the cooktop and ventilation system are in use. Never
allow children to sit or stand on an appliance. Do not let children play with a range, cooktop or ventilation system.
Do not store items of interest to children above or around the cooktop, range or range hood.
2_r
General S ecifications
Filters
Lights
Total Circuit
Requirements*
Total Connected
Load*
Blower Rating**
Mesh type, dishwasher safe
120 Vac, 75 Watt, halogen
120 Vac, 60 Hz., 15Amp. Min.
grounded, dedicated circuit
IVSI: 0.2 kW (2 Amp.)
IVS2:0.4 kW (3 Amp.)
IVSR1/IVSR2 0.2 kW (1.5 Amp.) plus
the power requirements of the in-line or
remote blower connected.
IVSI 600 CFM, IVS2:1200 CFM
IVSR1 and IVSR2: Dependant on
in-line or remote blower selected
The Dacor Integrated Ventilation System (IVS)is designed
for installation inside custom hood canopies. Proper
installation of the IVS requires proper selection of the
custom canopy materials and proper construction. Carefully
and closely follow all instructions and warnings concerning
the installation of the IVS within a combustible or non-
combustible hood canopy. Make sure that all construction
meets applicable local codes and regulations.
Electrical specifications provided for reference
only, consult product data label on the unit for exact
specifications.
** At zero inches static pressure
Product Dimensions
All dimensional tolerances are + 1/16", - 0" (+1.6 mm, -0) unless otherwise stated.
8" (20,3 cm) round exhaust
with back draft damper
Electrical
J access
holes
6" (15.2 cm)
8" (20,3 cm) round exhausts
with back draft damper
Electrical
access
/holes
6" (15.2 cm)
(28.1 cm)
12 1/4"
(31.1 cm_
IVSl, IVSR1
Overall Dimensions IVS2, IVSR2
Overall Dimensions
H
8" Exhaust _
6 1/2" 6 1/2"
(16.5 cm)(16.5 cm)
IVSl, IVSR1
Exhaust Placement
Top View
IVS2, IVSR2
Exhaust Placement
Top View
_mCD_ 3
Installation Requirements
To reduce the risk of fire, plan the installation so that
all minimum required clearances are met or exceeded.
Dimensions provided are minimum clearances, unless
otherwise noted.
An Integrated Ventilation System (IVS)installed in
a custom hood canopy constructed of combustible
materials must be installed with the combustible
material structure a minimum of 36" (914mm) above
the appliance cooking surface.
An IVS installed in a custom hood canopy that is
constructed of non-combustible materials must be
installed with the non-combustible material structure a
minimum of 30" (762mm) above the appliance cooking
surface.
An IVS installed in a custom hood canopy that is
constructed with a Dacor IHL series stainless steel
hood liner must be installed with the non-combustible
material structure a minimum of 30" (762mm) above
the appliance cooking surface.
The IVS must be mounted so that it can be removed if
service is required. Make sure that the material around
the edge of the cutout, behind the IVS mounting holes,
is strong enough to hold the weight of the unit.
Electrical Requirements Planning the Duct Work
To reduce the risk of fire and electric shock, the electric
service to the IVS must be installed only by a licensed
electrician.
To reduce the risk of fire and electric shock, install this
range hood only with an in-line or remote blower rated
maximum 7 Amps. (IVS1 and IVS2) or maximum 8 Amps.
(IVSR1 and IVSR2).
It is the owner's responsibility to ensure that the electrical
connection of this appliance is performed by a qualified
electrician. The electrical installation, including minimum
supply wire size and grounding, must be in accordance with
the National Electric code ANSI/NFPA* (or latest revision)
and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The ground wire on this appliance must be connected
to a grounded, metallic, permanent wiring system or
grounding conductor installed by a licensed electrician.
Do not ground the appliance or appliance wiring to a
gas pipeline or to the neutral (white) power supply wire.
Do not install a fuse in the neutral or ground circuit.
Connect the IVS directly to an electrical junction box.
The IVS needs to be hard wired, according to local
code, directly to a dedicated three wire grounded,
single phase circuit rated at 120 Vac 60 Hz, 15 Amps.
To reduce the risk of fire and to properly exhaust
air, be sure to duct air outside the house or building.
Do not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces or garages.
To prevent combustion by-products, smoke or odors
from entering the home and to improve efficiency,
tape all duct joints securely.
Use only duct work deemed acceptable by state,
municipal and local codes.
Range hoods may interrupt the proper flow of
smoke and combustion gases from furnaces, gas
water heaters and fireplaces. To avoid drawing
lethal gases into the home, follow the manufactures
recommendation for these devices and consult
NFPA and ASHRAE recommendations.
When installing models IVS1 and IVS2, DO NOT
install an additional, external blower to increase
the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the
air draw by the hood.
When installing models IVSR1 and IVSR2, DO
NOT install more than one external blower to
increase the length of the duct run. Even small
differences between blower air flow rates can greatly
reduce the air draw by the hood. Install only the
in-line or remote blower models specified in these
instructions.
Duct System Design Requirements
All duct work materials (including screws and duct tape)
must be purchased separately by the customer.
Ducts must be of adequate size and duct runs should
be as short and straight as possible. Where turns are
necessary, keep the turning radius as large and smooth
as possible.
4_t
To prevent back-drafts, a damper at the duct outlet may
also be required. The IVS comes equipped with a back-
draft damper installed in the collar of the unit.
Make sure duct work does not interfere with floor joists
or wall studs.
The hood exhaust connects to a 8-inch round duct. You
can increase the duct size over the duct run if desired.
To prevent a back draft, never decrease the duct size
over the run. If existing duct work is smaller than 8
inches in diameter, remove it and replace it with 8-inch
or 10-inch duct work.
On dual exhaust models, the two 8 inch exhausts may
be merged into on 10 inch duct using Dacor transition
ATD10.
10 inch round
2" (5.1 cm)
\
\13" (33.0 cm'
\\\\
21" (53.3 cm!
Transition
Model ATD10 (20.3 cm)
Do not rely on tape alone to seal duct joints. Fasten all
connections with sheet metal screws and tape all joints
with certified silver tape or duct tape. Use sheet metal
screws as required to support the duct weight.
Do not use flexible metal duct.
Do not use duct work that is smaller in cross-sectional
area than 8-inch round duct.
Additional Requirements for Models IVSR1 and
IVSR2:
Models IVSR1 and IVSR2 are not equipped with an
internal blower. Installation of an in-line or remote blower is
required. See the table below for the correct model number.
DUCT WORK IN-LINE BLOWER REMOTE BLOWER
SIZE MODEL MODEL
8 inch ILHSF8 REMP3
10 inch ILHSF10 REMP16
Calculating the Maximum Duct Run Length
The maximum straight duct length for the hood is
determined by the type of duct used. See the chart below.
DUCT SIZE MAXIMUM DUCT RUN
8 inch round 60 feet
10 inch round 50 feet
3¼" X 10" rectangular 50 feet
For each elbow and transition added to the duct work,
a certain number of feet must be subtracted from the
maximum duct run to compensate for wind resistance. To
determine the length the duct work cannot exceed, subtract
all of the equivalent lengths of the elbows and transitions
listed below from the maximum duct run above.
Duct Work Equivalent Lengths
PIECE SUBTRACT PIECE SUBTRACT
8" 90 ° elbow 7 feet 10" 90° elbow 5 feet
8" 45 ° elbow 3 feet 10" 45° elbow 2 feet
3¼" X 10" 3¼" X 10" to
to round 90° 25 feet 8"110" round 4 feet
transition transition
3¼" X 10" 90 ° 3¼" X 10" 90 °
15 feet 20 feet
elbow flat elbow
3¼" X 10" 45° 7 feet Walt cap with .
elbow damper
Roof cap *
The equivalent lengths of roof and wall caps vary with
model and configuration. For equivalent length, contact the
manufacturer or a qualified HVAC specialist.
Duct Work Design Tips
When planning new duct work, always look for the shortest,
most direct route to the outside.
Wherever possible, reduce the number of transitions and
turns to as few sharp angles as possible. Two staggered
45 ° angles are better than one 90° .
Keep turns as far away from the hood exhaust as possible,
and as much space between bends as possible.
For best performance, use round duct instead of
rectangular, especially when elbows are required.
If multiple elbows are used, try to keep a minimum of 24
inches of straight duct between them. Avoid "S" or "back to
back" use of adjacent elbows.
In regions where the weather gets extremely cold, use
thermal breaks, such as a short section of non-metallic
duct, to avoid indoor heat loss. Locate the break as close
as possible to the outside pass through point.
_mCDK 5
Installing the IVS
,
,
3.
,
If installing a hood liner (Dacor series IHL) install it
before installing the IVS.
Remove the filters from the IVS.
The IVS comes pre-wired from the factory. Insert the
unit into the cutout while routing the wiring harness to
the junction box.
While holding the IVS in place, attach it to the cutout
with screws (not supplied) through the mounting holes
around the edge.
I
I
I
I
I
Electrical
wiring
harness
i
Installing the Duct Work
J Electrical
access
holes
,
,
Models IVSR1 and IVSR2 only: Install the remote or
in-line blower (see page 5 for specifications) according
to the blower installation instructions.
Install the duct work starting from the hood working
toward the outside vent. Observe the specifications
on pages 4 and 5. Fasten all joints with sheet metal
screws and seal with duct tape or certified silver tape.
The duct work must be air tight. Use a minimum of two
(2) sheet metal screws at every duct joint. Seal all duct
joints with a high quality duct tape.
Electrical Connection
,
,
Models IVSR1 and IVSR2 only: Route the wiring from
the in-line or remote blower into the IVS through one of
the electrical access holes in the hood. Connect them
to the remote blower (REMP) connection terminal as
shown below. Match wire colors.
REMP wiring terminal
inside hood X_
I_ I_ Not used
GREEN _11_i_O_
" WHITE I_ _111 _ol_L_tr_j I N1 WHITE
BLACK _ll_O_lk_ _21 L1 BLACK
Wiresfrom in-line/remote I/
blower Wires connected to hood
wiring harness, do not remove
Connect the pre-wired, white and green wires to the
corresponding black, white and ground (green) wire
from the power source wiring. Use wire nut connectors
to secure the connections.
6 _mC_
Verifying Proper Operation
1. Install the filters.
2. Install the light bulbs.
Attach the included suction cup to one of the
provided light bulbs.
Insert it into one of the light fixtures.
Screw it into place and remove the section cup.
Repeat for the remaining light fixtures.
I
3. Verify that the IVS control knobs are in the OFF
position (fully counter-clockwise).
4. Turn on the main power supply at the circuit breaker
panel or fuse box.
5. Turn the light and fan knobs clockwise and make sure
the lights and fans operate properly.
If the hood does not operate properly, follow these
troubleshooting steps:
Verify that power is being supplied to the IVS.
Check the electrical connections to ensure that the
installation has been completed correctly.
Repeat the above test.
If the installation still does not work, contact Dacor
Distinctive Service at (877) 337-3226. Do not attempt to
repair the unit yourself. Be sure to have all model and
serial numbers from the product data labels available
when you call.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
Installation Checklist
[] Is the IVS properly attached to the cutout or hood liner
according to the instructions on page 6?
[] Is the duct work completely installed? Are all joints
attached with sheet metal screws and wrapped with
duct tape? See page 6.
[] Is the range hood wired and grounded according to
these instructions and in accordance with all applicable
electric codes? See pages 4 and 6.
[] Are the filters properly installed according to the use
and care manual?
[] Has proper operation been verified?
[] Has the warranty been activated on-line or the warranty
card filled out completely and mailed?
_mCD_ 7
GROUND
@
NEUTRAL
WH _ BLK
HALOGENUGHTS(2)
WH _ BLK
FAN MOTOR
IVSi, IVSR1
UNE
LAMPDIMMER
t
FAN SWITCH
t
BLK
GROUND NEUTRAL UNE
@
VVI--I _ BLK
WH _ BLK
HALOGENUGHTS(3)
WH BLK
LAMPDIMMER
t
FANMOTORS
®
@
IVS2, IVSR2
BLK
8l::_mcl:Ir,
4#
Dacor • 600 Anton Blvd. Suite 1000 Costa Mesa, CA 92626 • Phone: (800) 793-0093 • Fax: (626)403-3130 www.Dacor.com
American Made*Family Owned
The Life of the Kitchen?

Navigation menu