Data Sciences TRUDSI Animal implant for medically related applications in laboratory environments User Manual TruSense Configuration Manual

Data Sciences International Inc Animal implant for medically related applications in laboratory environments TruSense Configuration Manual

System Users Manual

Download: Data Sciences TRUDSI Animal implant for medically related applications in laboratory environments User Manual TruSense Configuration Manual
Mirror Download [FCC.gov]Data Sciences TRUDSI Animal implant for medically related applications in laboratory environments User Manual TruSense Configuration Manual
Document ID1687830
Application IDRwRQ9Z0tfHELNkkSW4vRsA==
Document DescriptionSystem Users Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize250.51kB (3131325 bits)
Date Submitted2012-05-01 00:00:00
Date Available2012-06-27 00:00:00
Creation Date2012-05-01 11:41:49
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2012-05-01 21:25:45
Document TitleTruSense Configuration Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: John P. Kroehle, Jr.

DSI
TruSense Configuration
Manual
Model: TruSense
Manual: MU00285
Revision: 1
Data Sciences International
119 14th Street NW, Suite 100
St. Paul, MN 55112
Phone: +1 (651) 481-7400
US:
+1 (800) 262-9687
Email: support@datasci.com
www.datasci.com
Copyright 1997-2012 Data Sciences International. All rights reserved. No part of this manual may be
reproduced, translated, transcribed, or transmitted in any form or by any means manual, electronic,
electromagnetic, chemical, or optical without the written permission of Data Sciences International.
Data Sciences International
119 14th Street NW, Suite 100
St. Paul, MN 55112
Phone: +1 (651) 481-7400
US:
+1 (800) 262-9687
Email: support@datasci.com
www.datasci.com
www.datasci.com
Contents
TruSense Hardware Configuration................................................................................................................ 1
TruSense Hardware Configuration ............................................................................................ 1
Accessing TruSense Configuration from P3P ............................................................. 1
TruSense Wizard ....................................................................................................................... 3
Page 1: Select CLCs for Study ................................................................................... 3
Page 2: Frequency Configuration ................................................................................ 5
Page 3: Find All Implants Within Range ................................................................... 11
Page 4: Assign Implants to CLCs .............................................................................. 12
Page 5: Warning of Pending Changes ....................................................................... 13
Page 6: Change Implant Frequencies ........................................................................ 14
Page 7: Accept Configuration.................................................................................... 15
TruSense Hardware Configuration (confirmation) .................................................................. 16
Study CLC Details ..................................................................................................... 17
CLC Details ............................................................................................................... 18
Implant Details .......................................................................................................... 19
Interactive Features: .................................................................................................. 20
TruSense Hardware Configuration (completion) ..................................................................... 27
Appendix A: CLC Diagnostic Webpage .................................................................................. 29
CLC – The Communication Link Controller ............................................................. 29
TruSense Diagnostic Webpage .................................................................................. 30
Glossary ................................................................................................................................... 52
Index............................................................................................................................................................ 53
TruSense Configuration Manual
Contents
iii
TruSense Hardware
Configuration
TruSense Hardware Configuration
The TruSense system automates the collection of physiologic data from freely moving research animals via wireless
telemetry. The system consists of a sophisticated acquisition and analysis software platform and a family of
advanced, state of the art implantable telemetry transmitters. The communications link between these two
components consists of wired and wireless components collectively referred to as the TruSense Hardware.
Accessing TruSense Configuration from P3P
TruSense Configuration Manual
TruSense Hardware Configuration
From the menu bar click Hardware, and select Edit TruSense Configuration…
This opens the TruSense Hardware Configuration window.
If this is a new configuration, the red colored message text will inform you that you need to use
Configure Sources… to define telemetry implant sources.
Click on the Configure Sources… button to open the TruSense Wizard and begin the study
configuration process.
TruSense Hardware Configuration
TruSense Configuration Manual
TruSense Wizard
The TruSense Wizard is a step by step guide which presents the user with a sequence of dialog boxes. This insures
that the individual steps in the process are performed in correct order. There are seven pages in the configuration
process.
Page 1: Select CLCs for Study
Page 1 of the TruSense Wizard is basic inventory. The Wizard queries the network; it finds all of the active CLCs
(Com-Link Controller) on the system and lists them in the right hand column titled CLCs Currently on Network.
To configure a CLC for use in the system, select a CLC and move it from the right column, CLCs Currently on
Network to the left column, CLCs Selected for Study.
Select a CLC in the right column, click and hold the selection with the left mouse button and drag the
selection to the left column. Release the mouse button and the CLC will be added to the list.
TruSense Configuration Manual
TruSense Hardware Configuration
The newly added CLC will be added to the list with a circular status indicator.
Green colored indicator:
CLC enabled
Red colored indicator :
CLC disabled
If the colored status indicator does not change from red to green, an error message will be displayed in
the lower left corner of the screen.
TruSense Hardware Configuration
TruSense Configuration Manual
At least one CLC must be selected and enabled (green indicator) before continuing.
All of the “Selected” CLCs (left column) must be enabled before continuing.
If everything is in order, you will be able to click the Next button to proceed to Page 2.
If the Next button is not available, consult the error messages mentioned above.
NOTE: At any time a CLC information pop up is available by hovering your mouse cursor over
any of the CLC labels on the page.
Page 2: Frequency Configuration
Page 2 allows the user to select a separate frequency for each CLC. As many as four CLCs may be configured at
one time, but each CLC must be assigned a unique operating frequency.
TruSense Configuration Manual
TruSense Hardware Configuration
Assign Unique CLC Frequency
Frequencies to Scan
Assign Unique CLC Frequency
The CLCs that are enabled in the previous step are listed in the left hand column labeled Assign
Unique CLC Frequency.
TruSense Hardware Configuration
TruSense Configuration Manual
The left hand side of the page is arranged in a table.
Assign Unique CLC Frequency
CLC label
Current CLC freq:
Select freq.
CLC Label:
The name that is assigned to the CLC
Current CLC freq:
The currently assigned frequency
Select freq.:
Drop-down with freq. options
The current operating frequency of each CLC is listed in the center column.
Use the drop-down menu to the right of the CLC to select an available communication frequency.
The frequencies are designated by four alpha-numeric characters XX – YZ (XX = region, Y = freq,
Z = group).
Region
Frequency
Group
F1 = USA
F2 = Europe
TruSense Configuration Manual
TruSense Hardware Configuration
Guidelines for selecting frequencies
The frequency Group designation (above) is used to allocate certain frequencies as Primary or Secondary. Group
1 (A1, B1, C1, D1) is the Primary frequency and Group 2 (A2, B2, C2, D2) is the Secondary frequency. When
configuring multiple implants in adjoining cages, it is advisable to configure adjoining cages with alternating
frequency Groups. Example cage 1-Primary group; cage 2-Secondary group; Cage 3-Primary and so on…
Each CLC that the Wizard detects must be assigned a unique communication frequency.
CLC frequencies must be unique and should be from the same frequency Group.
A1, B1, C1, D1
A2, B2, C2, D2
The frequency options that are available to assign to CLCs are listed in the right hand column labeled
Frequencies to Scan.
The user must assign a unique frequency for each CLC before continuing to the next page.
To assign a frequency, left-click the down arrow
listed.
TruSense Hardware Configuration
of the drop-down menu associated with each CLC
TruSense Configuration Manual
Frequencies to Scan
The TruSense system consists of CLCs, TRXs, and telemetry implants. The proprietary communication protocols
use several different radio frequencies to communicate with the implants. All individual implants are assigned to a
particular frequency. New implants that have not been previously configured will be detectable using the default
frequency assigned during manufacturing. If you wish to re-configure an implant that has been altered from the
default frequency (previously configured); that implant’s communication frequency will need to be included in the
Frequencies to Scan dialog below.
In the previous section, Assign Unique CLC Frequency, the user assigns a separate frequency to each CLC. In
this section, the user selects which additional radio frequencies the system will scan in order to locate individual
implants. If all of the implants are previously un-configured, the user must only insure that the default shipping
frequency is assigned to a CLC in the left column – or is checked to be scanned in the right column.
The frequencies are designated by four alpha-numeric characters XX – YZ (XX = region, Y = freq.,
Z = group)
Region
Frequency
Group
F1 = USA
F2 = Europe
The frequencies that are assigned to CLCs in the left column, Assign Unique CLC Frequency,
will automatically be scanned for implants.
Once a frequency is selected for a CLC, that frequency is no longer offered as an option in the
Frequencies to Scan column.
The Frequencies to Scan column is provided so that the user will be able to locate implants that
have been previously assigned to other frequencies and allow them to be re-configured.
TruSense Configuration Manual
TruSense Hardware Configuration
The factory default frequencies for new implants are:
F1-B1 for USA
F2-B1 for EU
The TruSense Wizard can configure eight implants per configuration cycle, therefore there should
only be eight implants powered ON during this process.
NOTE: Implants are shipped with a factory default frequency already assigned. If an implant has
been subsequently configured with a non-default frequency it will not be located unless that
altered frequency has been selected to be scanned.
NOTE: If the frequency of a previously configured implant cannot be determined, the user may
choose to scan all of the available frequencies. The scanning of all available frequencies will take
extra time.
Click the Next button to progress to the next page – Find All Implants Within Range.
10
TruSense Hardware Configuration
TruSense Configuration Manual
Page 3: Find All Implants Within Range
In this step of the configuration process the CLCs incrementally scan the frequencies selected in the previous screen.
The “operational” telemetry implants, detectable in the network environment, will be listed in the left dialog box
labeled Found Implants.
The green progress bar tracks the status of the searching process and displays the frequency currently
being scanned.
NOTE: It is normal for this process to take several minutes.
Transmitters that are power ON, communicating, and within range will be listed in the Found
Implants column once they are identified.
Transmitters that were previously configured in a study, but not yet detected by this iteration of the
Wizard, will be listed on the right in the Implants Not Found column.
Implants will move from right to left as they are detected.
NOTE: Implants that are powered OFF will require a magnetic swipe in order to place them in a
communication mode.
TruSense Configuration Manual
TruSense Hardware Configuration
11
NOTE: At any time, an implant information pop up is available by hovering the mouse cursor over
the implant line item listed in a dialog box.
Once the scanning process is complete and all of the implants are identified, the progress bar will be
solid green and the message “Scanning Frequencies … Process Complete” will appear below
the progress bar.
Click NEXT to proceed to the next step – Assign Implants to CLCs.
Page 4: Assign Implants to CLCs
This stage of the process allows the user to custom configure the system to assign individual implants to specific
CLCs: i.e. “I would like Implant A to be assigned to CLC #4, communicating on frequency F1-A1.”
The implants that have already been assigned to CLCs will automatically be shown in the left column
labeled CLC / Implant Assignment.
The implants that have not been previously assigned to a CLC will appear in the right column labeled
Found / Available Implants.
To assign an available implant, click on the implant name in the right column and drag the implant into
the box below the desired CLC on the left.
Once all of the implants are assigned to the appropriate CLCs, Click Next.
12
TruSense Hardware Configuration
TruSense Configuration Manual
Page 5: Warning of Pending Changes
Page 5 is a confirmation page that warns the user that the pending changes are about to be committed.
The Pending Changes are listed in the dialog box on the left. There is no user interaction in this step
of the Wizard, it merely warns the user that once the Next button is pressed, there is no “Undo” option.
 WARNING: Once the process is initiated, do not alter any components of the system.
TruSense Configuration Manual
TruSense Hardware Configuration
13
Click Next to progress to Page 6: Change Implant Frequencies.
Page 6: Change Implant Frequencies
Page six is the actual re-assignment process. One by one, the CLCs instruct the implants to switch
frequencies and the implants comply. Once an implant switches to a new frequency, it can no longer
communicate with its previously assigned CLC. The implant must then wait until a CLC on its new
frequency attempts to contact it.
The green progress bar shows the status of the re-assignment process and displays the pertinent
information.
NOTE: This process may take several minutes.
As the re-assignments progress, the information in the text box below the CLC listing will
continuously update.
There is no overt confirmation that individual changes have occurred.
Do not alter any components of the system until confirmation that the process is complete.
Completion of the process is indicated by a completely green progress bar with the message “Process
Complete” below.
14
TruSense Hardware Configuration
TruSense Configuration Manual
Click Next to progress to Page 7: Accept Configuration.
Page 7: Accept Configuration
Page seven is the final step in the TruSense Wizard. The column on the left, Configuration,
presents the newly configured tree structure of CLCs and implants. The column on the right, Summary
of Changes, will indicate successes and failures in the configuration process. If the user wishes to
alter or repair the final configuration listed in the Configuration dialog box, the wizard will have to be
run again.
The Configuration column on the left, outlines the new hardware configuration.
Study Configuration
 CLC 1
Implant 1
Implant 2
 CLC 2
Implant 1
To accept and save the study configuration as it is outlined in the Configuration dialog box, click the
Finish button.
TruSense Configuration Manual
TruSense Hardware Configuration
15
TruSense Hardware Configuration (confirmation)
Once the TruSense Wizard closes, the configuration process is complete. The TruSense Hardware
Configuration screen is updated with the new Study Configuration.
There are multiple layers of information contained in this window:
Study CLC Details
CLC Details
Implant Details
16
TruSense Hardware Configuration
TruSense Configuration Manual
Study CLC Details
The Study CLC Details screen shows the overall configuration from the “Study” level. To view the
Study CLC Details level, click on the Study Configuration line item in the left column labeled
Configuration.
TruSense Configuration Manual
TruSense Hardware Configuration
17
The Configuration column lists the entire configuration in an expandable tree structure.
The CLCs are listed with the assigned transmitters listed underneath.
Click on the Study Configuration line item in the left column labeled Configuration.
The right hand column Study CLC Details, lists the CLCs in the new configuration.
Hover the mouse cursor over any line item in the Configuration box to activate an information
pop-up with that device’s key status condition.
The tree structure can be expanded and contracted by clicking on the [+] and [-] icons to the left
of the individual line items.
CLC Details
The CLC Details view can be accessed by left-clicking on any of the CLC line items in the
Configuration column on the left.
CLC Details include:
18
TruSense Hardware Configuration
TruSense Configuration Manual
CLC Name:
User-specified name or default name assigned by
manufacturer
About:
Specific information for that particular CLC
Implants:
List of the implant names assigned to that CLC
TRXs:
List of TRXs assigned to that CLC – the “Jack” number on
the back panel of the CLC that the TRX is plugged into
Implant Details
The Implant Details view can be accessed by left-clicking on any of the implant names in the
Configuration column. There is a lot of information available in this screen as well as some important
interactive features.
Information:
TruSense Configuration Manual
TruSense Hardware Configuration
19
Implant Name:
User-specified name or default name assigned by manufacturer
About:
Important information including model and serial numbers, activation
and manufacture dates, as well as a battery level indicator. (This same
information is available by hovering the mouse cursor over the line
item in the Configuration column.)
Interactive Features:
The Implant Details view can be accessed by left-clicking on any of the implant line items in the
Configuration column on the left. There are several important implant configuration options available
in the Implant Details portion of the hardware configuration screen.
Enabled:
This check box will toggle the Implant between ‘Enabled’ and ‘Disabled’ modes.
20
TruSense Hardware Configuration
TruSense Configuration Manual
The Enabled mode allows the software system to record, store, and analyze data from the
implant.
 WARNING: If the implant is not “Enabled” the device will still be in communication with the
TRXs but no data from this implant will be visible to the analysis software.
Current Mode:
The Turn Implant Off button allows the user to remotely switch the implant to the OFF mode. Once
in the OFF mode, the implant cannot be remotely returned to the ON mode. The implant can only be
turned ON by physically swiping it with a strong magnet.
TruSense Configuration Manual
TruSense Hardware Configuration
21
 WARNING: Once the implant is switched OFF, it cannot be remotely toggled back ON.
Procedure for switching the Implant to the OFF mode:
1. Select the implant by clicking the line item in the Configuration column on the left of the
screen.
2. Click the button labeled Turn Implant Off.
3. Confirm your intentions by clicking the button labeled Turn Off.
4. The progress bar will indicate the status of the operation. The completed process will be
indicated by the statement “Implant has been turned off successfully.”
22
TruSense Hardware Configuration
TruSense Configuration Manual
5. Click the Close button to return to the Implant Details screen.
CAUTION: Once you turn off an implant it can only be returned to the ON state by physically
passing a strong magnet close to the implant device.
Active Channels:
The Active Channels dialog allows the user to select which data collection channels are activated in
the Implant. Active implant channels collect physiologic data and transmit the data through the
acquisition system to be stored in the data acquisition computer. Inactive channels do not collect
physiologic data, those particular implant functions are turned off.
Aside from avoiding the collection of unnecessary data, the in-activation of certain data channels has
the potential to preserve battery resources.
Channel Details
Locate an implant by expanding the Study Configuration tree structure in the
Configuration dialog box. The tree structure can be expanded and contracted by clicking on
the [+] and [-] icons to the left of the individual line items.
Click on the [+] icon to the left of implant name in the Configuration dialog box to view the
implant details.
The current “active” channels are listed in bold type in the Configuration box once the tree
structure is fully expanded. The inactive channels are listed in italic text.
TruSense Configuration Manual
TruSense Hardware Configuration
23
Activating Inactive Channels
The default channels for the particular implant type are automatically listed in the Active
Channels dialog box in the center of the Implant Details screen.
To activate an inactive channel, click on the desired channel label in the Inactive Channels:
dialog box, hold the mouse button, and drag the channel label to the Active Channels: dialog
box. Release the mouse button.
To render a channel inactive, click and drag an active channel from the Active Channels:
dialog to the Inactive Channels: dialog.
Model Template:
A Model Template can be created in order to identically configure a group of implants with the same
channel arrangement. Once the channel configuration is set for one of the implants, the user can save
the channel configuration as a template and apply that configuration template to all of the similar
implants in a particular study configuration.
1. Select an implant from the Configuration column on the left side of the screen.
24
TruSense Hardware Configuration
TruSense Configuration Manual
2. Use the Active Channels dialogdialog to configure the implant in the manner you wish to
save as a template.
NOTE: Only one Model Template can be saved per implant model type.
3. Click the Save as Template button.
4. You will be offered a confirmation message “are you sure you want to replace the
template …?”
5. Click Yes to confirm.
Apply Templates:
Once an implant configuration is saved as a Model Template, that identical channel configuration can
be applied to any of the implants in the Study Configuration (provided that the implants are the
same model number).
1. Follow the procedure in the Model Template section to save an implant configuration
template.
TruSense Configuration Manual
TruSense Hardware Configuration
25
2. To apply the saved template to other implants in the Configuration list click the Apply
Templates… button in the lower left corner of the window.
3. This opens the Apply Implant Channel Configuration screen.
4. Open the drop-down menu under Choose implant or template to apply: and select the
saved template you wish to apply to the other implants.
5. In the Apply channel configuration to: dialog box, select the individual implants to which
the template should be applied. Select the implants using the check boxes next to the implant
label.
6. The Select All check box can be used to select\deselect all of the implants in the dialog box.
7. Click OK to apply the saved template configuration.
26
TruSense Hardware Configuration
TruSense Configuration Manual
8. A Confirm Operation dialog is offered as a precaution, click OK to accept.
TruSense Hardware Configuration (completion)
This completes the TruSense Hardware Configuration.
To save the configuration file and exit the configuration wizard, click the Save & Exit button.
TruSense Configuration Manual
TruSense Hardware Configuration
27
Appendix A: CLC Diagnostic Webpage
CLC – The Communication Link Controller
Communication Link Controller – processes telemetered data to/from the TRX for communications over the
Ethernet connection.
Illustration of the back panel of a CLC (Com Link Controller)
Accessing TruSense Diagnostics from P3P
The TruSense Diagnostic User Interface is a browser based webpage that allows the user to check the status
of the TruSense hardware components, update firmware, and perfom diagnostic tests to optimze the
performance of the system components.
The TruSense Diagnostic User Interface is accessed from the P3Plus Hardware menu.
From the menu bar click Hardware, and select TruSense Diagnostic UI…
This opens the TruSense Diagnostic Webpage in a internet browser window.
TruSense Configuration Manual
TruSense Hardware Configuration
29
TruSense Diagnostic Webpage
The TruSense Diagnostic User Interface is a browser based webpage that allows the user to check the status
of the TruSense hardware components, update firmware, and perfom diagnostic tests to optimze the
performance of the system components.
To Select a specific CLC click on the drop-down menu located in the top left corner of the TruSense
diagnostics window. All of the configured CLCs that are connected to the system will appear in this list.
CLC Options
The CLC Section of the Diagnostic Webpage has the following sections:
30
TruSense Hardware Configuration
TruSense Configuration Manual
Home
Network
Upload CLC Firmware
System Status
Settings
Reboot
Each of these will be described in a separate section below.
Home
Name :
User-selected name
Model Number:
Serial Number:
(Format = YYYY-MM-DD)
Manufacturing Date:
Version:
(Format = XX-YZ)
Operating Frequency:
Region
Frequency
Group
F1 = US
F2 = EU
Table 1. The frequencies are designated by four alpha-numeric characters XX-YZ (XX = region, Y = freq., Z = group)
TruSense Configuration Manual
TruSense Hardware Configuration
31
NOTE: the CLC adopts the frequency of the first TRX that it is connected to. This can be changed
later through the TruSense Hardware Configuration process
NOTE: the Operating Frequency will read “Unknown” if CLC is powered up without a TRX
connected.
32
Operating Mode:
Enabled = functioning properly
Disabled = indicates that there is no TRX found
System IP Address:
IP address of the data acquisition computercomputer
CLC IP Address:
The IP address of this particular CLC.
MAC Address:
Unique identifier for the CLC network interface
Time:
Current Date & Time (Format = YR-MO-DY HR:MN:SC)
Up Time:
Status information since last reboot
POST:
Power On Self Test (0 = Passed, OK …)
TruSense Hardware Configuration
TruSense Configuration Manual
Network (Settings)
Obtain an IP address automatically
This is the normal operating mode for the CLC. With this option
selected the CLC is queried and the values that it reports back are
displayed in the appropriate text boxes:
IP v4 Address:
Subnet Mask:
Default Gateway:
NOTE: There is also a Reset button on the back of the
CLC which reboots the CLC. This action may generate a
new IP address.
Use the following IP address
If for some reason the user wishes to manually assign a specific IP address to the CLC, click this option
button and type a new IP address in the text box.
CAUTION: In the event that the user-assigned IP address
is not accessible, this diagnostics tool will lose contact
with the CLC. The CLC will have to be reset.
If you wish to perform this operation, follow this procedure:
1.
2.
Click the option button for Use the following IP address
Enter the desired values in the text boxes labeled:
IP v4 Address:
Subnet Mask:
Default Gateway:
3. Click Apply
NOTE: A reboot of the system will have to be performed in order for the new IP Address to
activate.
TruSense Configuration Manual
TruSense Hardware Configuration
33
Upload CLC Firmware
This page allows the user to update the CLC firmware. From time to time it may be advantageous to upgrade
the internal read-only program instructions through a firmware upgrade. This often results in improved
performance.
To update or change the firmware version in the CLC, follow this procedure:
1.
2.
3.
4.
5.
Click on the Browse button and use the file upload window to locate the firmware file.
Navigate to the specific filename and click Open
Message 1: Uploading
Message 2: Uploaded
Message 3: Validating
NOTE: A reboot of the system will have to be performed in order for the new IP Address to
activate.
34
TruSense Hardware Configuration
TruSense Configuration Manual
System Status
The System Status is a continuously updating “log” file of the CLC’s communication activity. It can be used
to monitor communication issues in the event of discontinuities.
Contents:
NTP Status – Reports the last time the CLC received an update from the NTP Server
Active Processes and Memory Usage
System Log
TruSense Configuration Manual
TruSense Hardware Configuration
35
Settings
The Settings page allows the user to monitor the RF Mode.
Enabled – Normal operating mode
Disabled – Halts communication between the TRXs and the implants
Reboot
This function allows the user to perform a complete reboot of the CLC. A Reboot of the system is required to:
Activate a firmware upgrade (page xx)
Change the IP settings (page yy)
To reboot the CLC left click the Reboot button
NOTE: the Reboot process may take several minutes to
complete. There are no progress indicators that appear on
this page, However there are indicator lights on the back
of the CLC box itself.
TRX Options
The TRX is the three letter designation for a Transceiver: the component in the system that receives RadioFrequency (RF) signals and converts it into digital form that is sent, via cable, to the Communication Link
Controller; additionally, the component that transmits Radio-Frequency signals converted from digital form
sent via cable, from the Communication Link Controller
36
TruSense Hardware Configuration
TruSense Configuration Manual
TRX Status
The TRX Status screen is a non-interactive snapshot of the current status of the TRXs that are connected to
the CLC. Each CLC is capable of interfacing with eight TRXs. This arrangement mimics the configuration
on the rear panel of the CLC unit.
TRX Status screen indicating that two TRX units are connected and enabled.
The line items are as follows:
TRX (#): Number 1-8
Enabled: A check mark in the box indicates that the TRX is connected and
available to communicate with the implants
Connected: Indicates whether the TRX is physically CONNECTED or NOT
CONNECTED to the CLC
Model Number:
Serial number:
Manufacture Date: YYYY-MM-DD
Assembly Revision:
Loader Revision:
TruSense Configuration Manual
TruSense Hardware Configuration
37
Firmware Revision:
Error Status: Indicates that at least one error has occurred
Last error: The most recent error encountered
POST: Power On Self Test (0 =Passed, OK)
38
TruSense Hardware Configuration
TruSense Configuration Manual
TRX Commands
This dialog screen allows the user to perform two functions that affect the performance of the TRX. The user
can upload a different version of the on-board read-only software (firmware). Additionally the user can adjust
the telemetry receiver thresholds to optimize RF communications.
There are four commands available in this window.
Upload Firmware
To update or change the firmware version in the TRX, follow these steps:
1. Click on the TRX No drop-down menu and select the TRX number you wish to communicate with.
2. Click on the TRX Command drop-down menu and select Reset
3. Type the digits 01 in the dialog box highlighted in Figure 2.
Dialog box highlighted in Yellow
4. Click the Send button to initiate the command.
5. Return to the TRX Command drop-down menu and select Upload Firmware
TruSense Configuration Manual
TruSense Hardware Configuration
39
6. Click on the Browse… button and use the file upload window to locate the firmware file
7.
8.
9.
10.
Navigate to the specific filename and click Open
Message 1: Uploading
Message 2: Uploaded
Message 3: Validating
Get RSSI Threshold
RSSI stands for Received Signal Strength Indicator. It is a quantitative measure of the strength of the RF
signal that the TRX is receiving from the implants. The Get RSSI Threshold command retrieves the current
threshold value from the TRX. The default value = 0x12
1. Select Get RSSI Threshold from the TRX Command: drop-down menu.
2. Click Send.
40
TruSense Hardware Configuration
TruSense Configuration Manual
3. A successful operation is indicated by a blue colored Command Completed banner at the top of the
screen and a text string below the word Reply at the bottom of the screen.
4. The reported text value OK “xx” is the Hex value of the RSSI Threshold.
Set RSSI Threshold
RSSI stands for Received Signal Strength Indicator. It is a quantitative measure of the strength of the RF
signal that the TRX is receiving from the implants. The Set RSSI Threshold command allows the user to
adjust the lower limit of signal strength that the TRX will accept as viable information from the Implants.
The default value = 0x12
NOTE: Anytime the TRX is unplugged, or the CLC is rebooted, the RSSI threshold value will revert
back to the default value of 0x12.
1. Select Set RSSI Threshold from the TRX Command: drop-dowmn menu.
2. Select the TRX # from the TRX No: drop-down menu.
3. Enter a value in the small text box above the Send button.
TruSense Configuration Manual
TruSense Hardware Configuration
41
4. Click the Send button.
5.
A successful operation is indicated by a blue colored Command Completed banner at the top of the
screen and a text string “OK” below the word Reply at the bottom of the screen.
Reset
The Reset function returns the TRX settings to the factory default values.
1. Select Reset from the TRX Command: drop-dowmn menu.
2. Select the TRX # from the TRX No: drop-down menu.
3. Click the Send button.
4. A successful operation is indicated by a blue colored Command Completed banner at the top of the
screen and a text string “OK” below the word Reply at the bottom of the screen.
TRX RSSI History
These graphs allow the user to track how well the TRXs are receiving RF signals from the implants. In an
actively running system these graphs continually update according to a user prescribed auto refresh rate.
There will be one RSSI graph displayed for each of the enabled TRXs connected to the CLC.
42
TruSense Hardware Configuration
TruSense Configuration Manual
The TRXs will average the received signals from all of the implants it is communicating with. It will
then average the implant signals and report an average value for each graph.
Graphical representation of the average strength of the signals received from the implants
To set the auto refresh rate of the graph click on the drop-down menu at the top of the screen and
select a new value.
TRX CCA RSSI History
CCA is an acronym for Clear Channel Assessment. According to certain RF regulation environments, it is
necessary to invoke a “listen before you talk” policy. The Clear Channel Assessment operation determines
whether the wireless medium is busy or idle. The MAC layer can then make a decision on whether to send a
frame.
TruSense Configuration Manual
TruSense Hardware Configuration
43
The CLC will display the RSSI value of what the TRX is receiving. If the TRX picks up a significant signal from a
competing device the CLC delays the transmission of a command to the implant. If the interfering signal
persists; communication with the implants may be disrupted.
The CLC will try to avoid talking in a noisy RF environment
The CLC will display an RSSI value of what the TRX is picking up in the Join window.
In Europe the “Listen Before Talk” function is enabled by default
In the United States the “Listen Before Talk” function is disabled default
There will be one plot for each of the implants assigned to the CLC
To set the auto refresh rate of the graph click on the drop-down menu at the top of the screen and
select a new value.
44
TruSense Hardware Configuration
TruSense Configuration Manual
Implant Options
In this document the term implant simply refers to a TruSense Telemetry Transmitter.
TruSense Configuration Manual
TruSense Hardware Configuration
45
Implant Status
Implant Status is a non-interactive table which reports the operational status of all of the implants that are
communicating with a CLC.
There will be one eight-row table for each implant. The content of the rows is as follows:
Implant Serial Number
Manufacture Date YYYY-MM-DD
Assembly Revision
Application Version
Model
Last Uplink Time YYYY-MM-DD
standby
Mode
active
unused
Next Mode
Definitions:
Last Uplink Time – The latest time that the CLC received an uplink from the implant
Mode Options:
46
Standby – not actively transmitting data
Active – actively transmitting data
TruSense Hardware Configuration
TruSense Configuration Manual
o
Unused – configured but probably out of range
Next Mode: (This feature is not yet implemented)
Implant Commands
There are three modes in which the user can communicate with individual implants. They are Ping; Get
RSSI Threshold; and Set RSSI Threshold.
The Ping command allows the user to select an individual transmitter and request a confirmation
message that the implant is functional and within operating range.
The Get RSSI Threshold command retrieves the current threshold value from the TRX.
The Set RSSI Threshold command allows the user to adjust the lower limit of signal strength that
the TRX will accept as viable information from the Implants.
The “Ping” Command
The Ping command allows the user to send a request to an individual transmitter to reply with a confirmation
message that the implant is functional and within operating range.
TruSense Configuration Manual
TruSense Hardware Configuration
47
1. Click on the drop-down menu labeled Implant ID:
2. Select a device by left clicking on an implant serial number.
3. Click on the drop-down menu labeled Implant Command.
4. Left click the Ping command
5. Click the Send button
If the Ping dialog is successful:
A blue colored banner with the word OK! will appear at the top of the screen.
The implant will report back with a Hex value which is displayed in the Reply table at the bottom of
the screen.
If the Ping dialog is unsuccessful:
The Ping will be automatically repeated several times. If the implant fails to respond, a red colored banner
will appear at the top of the Screen.
48
TruSense Hardware Configuration
TruSense Configuration Manual
A red colored banner with the word ERROR will appear at the top of the screen.
The implant will not report with a Hex value at the bottom of the screen.
NOTE: It may take several seconds for an unsuccessful Ping command to generate an error message
Get RSSI Threshold
The Get RSSI Threshold command retrieves the current threshold value from the TRX. Get RSSI
Threshold reads the signal strength value that allows the implant to hear commands from the CLC/TRX.
1. Click on the drop-down menu labeled Implant ID:
2. Select a device by left clicking on an implant serial number.
3. Click on the drop-down menu labeled Implant Command.
4. Left click the Get RSSI Threshold command.
5. Click the Send button
TruSense Configuration Manual
TruSense Hardware Configuration
49
6. A successful operation is indicated by a blue colored OK banner at the top of the screen.
7. A Hex value will also be reported in a table below the word Reply.
Set RSSI Threshold
RSSI stands for Received Signal Strength Indicator. It is a quantitative measure of the strength of the RF
signal that the TRX is receiving from the implants. The Set RSSI Threshold command allows the user to
adjust the lower limit of signal strength that the TRX will accept as viable information from the Implants.
1. Click on the drop-down menu labeled Implant ID:
2. Select a device by left clicking on an implant serial number.
3. Click on the drop-down menu labeled Implant Command.
4. Left click the Set RSSI Threshold command.
5. A small text-entry box will appear below the Implant Command: line.
Allowable options for RSSI Threshold
0C
1C
6. Enter a new value for the RSSI Threshold and click the Send button
7. A blue colored banner with the word OK! will appear at the top of the screen.
50
TruSense Hardware Configuration
TruSense Configuration Manual
8. Repeat the Get RSSI Threshold procedure for verification.
Implant RSSI History
Similar to the TRX RSSI History, the Implant RSSI History generates graphs in which the received signal
strength from each of the TRXs is plotted for each implant. These graphs allow the user to track how well the
implants are being received by each of the TRXs. In an actively running system these graphs continually
update according to a user prescribed auto refresh rate.
There will be one RSSI graph for each of the recognized implants in the system.
Each implant will report the received signal strength from each of the TRXs it is communicating with.
The RSSI graph will display one data set for each of the TRXs.
To Set the Auto refresh rate of the graph, click on the drop-down menu at the top of the screen and
select a new value.
TruSense Configuration Manual
TruSense Hardware Configuration
51
Glossary
1. CCA = Clear Channel Assessment - Clear channel assessment - The clear channel assessment
operation determines whether the wireless medium is busy or idle. The MAC layer can then make a
decision on whether to send a frame.
2. CLC = Communication Link Controller – processes telemetered data to/from the TRX for communications
over the Ethernet connection.
3. Firmware = The combination of a hardware device and computer instructions and data that reside as
read-only software on that device
4. IP Address = Internet Protocol address is a numerical label assigned to each device participating in a
computer network that uses the Internet Protocol for communication
5. LBT = Listen Before Talk (LBT) or sometimes called Listen Before Transmit is a technique used in radio
communications whereby a radio transmitter first senses its radio environment before it starts a
transmission.
6. MAC Address = Media Access Control Address, is a unique identifier assigned to network interfaces for
communications on the physical network segment.
7. NTP = Network Time Protocol is a protocol and software implementation for synchronizing the clocks of
computer systems over packet-switched, variable-latency data network
8. RSSI = Received Signal Strength Indicator (or Indication): A signal or circuit that indicates the strength of
the incoming (received) signal in a receiver.
9. TRX = Transceiver: Component that receives Radio-Frequency signals and converts it into digital form
that is sent, via cable, to the Communication Link Controller; additionally, the component that transmits
Radio-Frequency signals converted from digital form sent via cable, from the Communication Link
Controller
52
TruSense Hardware Configuration
TruSense Configuration Manual
Index
No index entries found.
TruSense Configuration Manual
Index
53
Telemetry Transmitter User Guide Appendix –
Compliance Statement (Draft)
Thank you for purchasing DSI Telemetry Transmitters. DSI is required to provide this guide
because the devices transmit information using radiofrequency waves. It contains details on the
intended use of the transmitters, 1999/5/EC (R&TTE Directive) conformity, FCC compliance,
and proper transmitter disposal. Please read this guide carefully and retain for future reference.
For additional information on the product warranty, exchanges, and use, please visit
www.datasci.com.
Intended Use:
DSI Telemetry Transmitters are intended for measuring physiologic parameters in laboratory
animals. Transmitters range in size to accommodate a wide range of research animals and the
transmitter shape allows for subcutaneous or intraperitoneal placement.
Declaration of Conformity:
These transmitters conform to the requirements of 1999/5/EC (R&TTE Directive). The
declaration of conformity may be viewed on the Internet at www.datasci.com.
Use of 455 kHz devices may be subject to licensing in the following countries. For licensing
options please contact the national spectrum management authorities:
Italy
Use of 18 MHz devices may be subject to licensing in the following countries. For licensing
options please contact the national spectrum management authorities:
Belgium
Greece
Italy
Slovak Republic
Spain
Use of 868 MHz devices may be subject to licensing in the following countries. For licensing
options please contact the national spectrum management authorities:
Austria
Greece
Norway
Spain
Sweden
Netherlands
FCC Statement:
FCC ID
455 kHz Implant
FCCID:MHA02DSI
These devices comply with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference and (2) this device must accept
any interference that may cause undesired operation.
This Category II radio communication device complies with Industry Canada Standard RSS-310.
Ce dispositif de radio communication de catégorie II respecte la norme CNR-310 d’Industrie
Canada.
FCC ID
IC ID
8 MHz Implant
FCCID:MHATMS1
IC:5681A-MHATMS1
18 MHz Implant
FCCID:MHATMS2
IC:5681A-MHATMS2
These devices comply with Part 15 of the FCC rules and Industry Canada (IC) RSS 210.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference and (2) this device must accept any interference that may cause undesired operation.
Part Number 000380-001 Rev 09
Telemetry Transmitter User Guide Appendix –
Compliance Statement (Draft)
916 MHz Implant
916 MHz Transceiver
FCC ID
FCCID: MHATRUDSI
FCC ID
FCCID: MHATRXDSI
IC ID
IC: 5681A-MHATRUDSI
IC ID
IC: 5681A-MHATRXDSI
These devices comply with Part 15 of the FCC rules and Industry Canada (IC) RSS 210.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference and (2) this device must accept any interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Transmitter Disposal
Transmitters contain a primary battery cell which may contain lithium. The battery cell may be
removed by destructively dismantling the transmitter. Recycle the battery cell and remaining
electronics in accordance with applicable federal, state, and local regulations.
Part Number 000380-001 Rev 09

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-702
Create Date                     : 2012:05:01 11:41:49-04:00
Creator Tool                    : Microsoft® Office Word 2007
Modify Date                     : 2012:05:01 21:25:45-04:00
Metadata Date                   : 2012:05:01 21:25:45-04:00
Format                          : application/pdf
Creator                         : John P. Kroehle, Jr.
Title                           : TruSense Configuration Manual
Producer                        : Microsoft® Office Word 2007
Document ID                     : uuid:f48c06c8-470a-475c-96f0-c0881c297091
Instance ID                     : uuid:6d0c5b19-ca93-403d-b9fb-cc7695f80a2a
Page Count                      : 59
Language                        : en-US
Author                          : John P. Kroehle, Jr.
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MHATRUDSI

Navigation menu