Digi XBEEXSC XBee-PRO XSC RF Module User Manual manual xs oem rf module v42b5
Digi International Inc XBee-PRO XSC RF Module manual xs oem rf module v42b5
Digi >
Contents
- 1. User Manual
- 2. Antenna List
User Manual
XBee-PRO™ XSC RF Module XBee-PRO XSC RF Module RF Module Operation RF Module Configuration Appendices Product Manual 90000938-A For RF Module Part Number: XBP09-XC… 900 MHz OEM RF Modules by Digi International Inc. P r e l i m i n a r y 11001 Bren Road East Minnetonka, MN 55343 www.digi.com D r a f t XBee‐PRO™ XSC RF Module ‐ Product Manual 90000938‐A [2008.2.25] © 2008 Digi International, Inc. All rights reserved No part of the contents of this manual may be transmitted or reproduced in any form or by any means without the written permission of Digi International, Inc. XBee‐PRO™ is a registered trademark of Digi International Inc. Technical Support: Phone: (801) 765‐9885 Live Chat: www.digi.com E‐mail: support@digi.com © 2008 Digi International, Inc. ii XBee‐PRO™ XSC OEM RF Modules ‐ ZigBee ‐ v4.2B5 Preliminary Draft Contents 1. XBee-PRO™ XSC OEM RF Module.......... 4 Key Features......................................... 5 Worldwide Acceptance .......................... 5 Specifications ....................................... 6 Pin Signals............................................ 7 Electrical Characteristics ...................... 8 Timing Specifications ............................ 8 Mechanical Drawings ............................ 9 2.RF Module Operation .......................... 10 Serial Communications ....................... 10 UART-Interfaced Data Flow.................. 10 Serial Data ........................................ 10 Flow Control ...................................... 11 Modes of Operation ............................ 12 Idle Mode .......................................... 12 Transmit Mode ................................... 12 Receive Mode .................................... 14 Sleep Mode ....................................... 14 Command Mode ................................. 17 3.RF Module Configuration..................... 19 Programming Examples ...................... 19 AT Commands ................................... 19 Binary Commands .............................. 19 Command Reference Table ................. 20 Command Descriptions ...................... 21 Agency Certifications 33 FCC (United States) Certification ........ 33 Labeling Requirements ........................ 33 FCC Notices ....................................... 33 Limited Modular Approval .................... 33 FCC-approved Antennas ...................... 34 IC (Industry Canada) Certification ..... 34 Additional Information ........................... 38 5-Year Warranty ................................. 38 Ordering Information ......................... 38 Contact Digi ........................................ 40 © 2008 Digi Internaitonal, Inc. XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 1. XBee‐PRO™ XSC OEM RF Module The XBee-PRO XSC (900 MHz) OEM RF Modules were engineered to afford OEMs and integrators an easy-to-use RF solution that provides reliable delivery of critical data between remote devices. These modules come configured to sustain reliable long range wireless links. The XBee-PRO Module is a drop-in wireless solution that transfers a standard asynchronous serial data stream. © 2008 Digi International, Inc. XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 1.1. Key Features Long Range Data Integrity Easy-to-Use XBee-PRO XSC (900 MHz) Range: • Indoor/Urban: up to 1200' (370m) • Continuous RF data stream up to 9600 bps • Outdoor line-of-sight: up to 6 miles (9.6 km) w/ 2.1 dBm dipole antenna • No configuration required for out-of-box RF data communications • Outdoor line-of-sight: up to 15 miles (24 km) w/ high gain antenna • Advanced configurations available throu standard AT & binary Commands • Receiver Sensitivity: -106 dBm (900 MHz), Advanced Networking & Security • Portable (small form factor easily design into a wide range of data radio systems • True peer-to-peer (no "master" required) communications • Software-selectable serial interfacing ra • Point-to-point & point-to-multipoint topologies supported • Retries and Acknowledgements • 7 hopping channels, each with over 65,000 available network addresses • MODBUS, CTS, RTS, DTR, DCD (& more I/O Support • Support for multiple data formats (parity, start and stop bits, etc.) • XII™ Interference Immunity • Power-saving Sleep Modes • FHSS (Frequency Hopping Spread Spectrum) • Input pins are 5 volt tolerant 1.1.1. Worldwide Acceptance FCC Certified (USA) - Refer to Appendix A for FCC Requirements. Systems that include XBee-PRO Modules inherit Digi’s FCC Certification ISM (Industrial, Scientific & Medical) frequency band Manufactured under ISO 9001:2000 registered standards XBee-PRO™ XSC (900 MHz) OEM RF Modules are approved for use in US and Canada. © 2008 Digi International, Inc. XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 1.2. Specifications Table 1‐01. XBee‐PRO XSC OEM RF Module Specifications Specification XBee-PRO XSC (900 MHz) OEM RF Module Performance Indoor/Urban Range Outdoor line-of-sight Range Interface Data Rate Throughput Data Rate RF Data Rate Transmit Power Output Receiver Sensitivity up to 1200ft (370m) Up to 6 miles (9.6km) w/ dipole antenna Up to 15 miles (24 km) w/ high-gain antenna 125 - 65,000 bps (Software selectable, includes non-standard baud rates) 9,600 bps 10 kbps 100 mW (+20 dBm) -106dBm Power Requirements Supply Voltage 3.0-3.6 VDC regulated Receive Current 65mA Transmit Current 265mA Power Down Current 50 µA General Frequency Range 902.7-927.3 MHz Spread Spectrum Frequency Hopping, Wide band FM modulator Network Topology Point-to-Point, Peer-to-Peer, Point-to-Multipoint Channel Capacity 7 hop sequences share 25 frequencies Board-level Serial Data Interface CMOS UART Physical Properties Module Board Size Weight Connector Operating Temperature 1.297" x 0.962" x 0.215 (3.29 cm x 2.44 cm x 0.546 cm) Note: Dimensions do not include connector/antenna or pin lengths 5 to 8 grams, depending on the connector/antenna 2 rows of 10 pins, 22mm apart with 2mm spaced male Berg-type headers -40 to 85º C (industrial) Antenna Options Integrated Wire Integrated Helical ¼ wave monopole, 3.25” (8.26 cm) length, 1.9 dBi Gain 0.315" (0.8 cm) height Connector Reverse-polarity SMA or U.FL Impedance 50 ohms unbalanced Certifications ) FCC Part 15.247 MXQ-XBEEXSC Industry Canada (IC) 1846A-XBEEXSC Europe N/A RoHS Compliant © 2008 Digi International, Inc. XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 1.3. Pin Signals Figure 1‐01. XBee‐PRO XSC OEM RF Module Pin Numbers (top view, shield underneath) Table 1‐02. J1 Pin Signal Descriptions (Low‐asserted signals distinguished with a horizontal line over signal name.) Module Pin Public Signal Notes I/O When Active Function VCC DO (Data Out) n/a Serial data exiting the module (to the UART host). Refer to the Serial Communications section for more information DI (Data In n/a Serial data entering the module (from UART host). Refer to the Serial Communications section for more information. DO3 / RX LED high Pin is driven high during RF data reception; otherwise, the pin is driven low. Refer to the CD Command section to enable. Reset Has a 10k pull I/O up resistor low Re-boot module.(minimum pulse is 90us) Open Drain configuration. Module will drive reset line low momentarily on reboot and power up. Config Has a 100k pull up resistor low / high Pin can be used as a backup method for entering Command Mode during power-up. Primary method is with "+++". Refer to the AT Commandssection for more information. NC DI3 / SLEEP 10 GND 11 Has a 100k pull up resistor 3.0v to 3.6v Driven high Do not Connect Do not Connect high By default, DI3 pin is not used. To configure this pin to support Sleep Modes, refer to the Sleep Mode, SM Command and PW Command sections. Ground Driven high Do not Connect 12 DO2 / CTS / RS-485 Enable low CTS(clear-to-send) flow control - When pin is driven low, UART host is permitted to send serial data to the module. Refer to the Serial Communications and CS Command sections for more information. ---------------------------------------------------------------RS-485 Enable - To configure this pin to enable RS485 (2-wire or 4-wire) communications, refer to the Serial Communications and CS Command sections. 13 ON / Sleep high high = Indicates power is on and module is not in Sleep Mode. Low = Sleep mode or module is unpowered 14 ADCVRef n/a Voltage Reference should be tied to VCC n/a low = TX - Pin pulses low during transmission -------------------------------------------------------------high = PWR - Indicates power is on and module is not in Sleep Mode low RTS (request-to-send) flow control - By default, this pin is not used. To configure this pin to regulate the flow of serial data exiting the module, refer to the Serial Communications and RT Command sections. --------------------------------------------------------------CMD -Refer to Binary Commands and RT Commandsections to enable binary command programming. 15 16 TX / PWR DI2 / RTS / CMD Has a 100k pull down resistor 17 Driven low Do not Connect 18 Driven low Do not Connect 19 Driven low Do not Connect © 2008 Digi International, Inc. XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Module Pin Public Signal Notes 20 When Active I/O Driven low Module has 10K Ohm internal pull‐up resistor ** Module has 10K Ohm internal pull‐down resistor *** Module has 100K Ohm internal pull‐up resistor Function Do not Connect Note: When integrating the XBee-PRO XSC Module with a Host PC Board, all lines that are not used should be left disconnected (floating). 1.4. Electrical Characteristics Figure 1‐02. System Block Diagram Basic wireless link between hosts The data flow sequence is initiated when the first byte of data is received in the DI Buffer of the transmitting module (XBee-PRO Module A). As long as XBee-PRO Module A is not already receiving RF data, data in the DI Buffer is packetized, then transmitted over-the-air to XBee-PRO Module B. 1.4.1. Timing Specifications Figure 1‐03. Timing Specifications (ʺAʺ and ʺBʺ refer to Figure 1‐02.) © 2008 Digi International, Inc. XBee‐PRO™ XSC OEM RF Modules Table 1‐03. Preliminary Draft AC Characteristics (SY parameter = 0, symbols correspond to Figure 1‐02 and Figure 1‐03.) Symbol Description TTX Latency from the time data is transmitted until received 9600 baud rate (32 byte packet) 72.0 ms TTL Time that TX/PWR pin is driven low TRL Time that RX LED pin is driven high 25.6 ms TST Channel Initialization Time 35.0 ms Table 1‐04. 9600 timing (B=number of bytes) For 0 < B < 40, T = 46.27 + (0.73 * B) ms 16.8 ms For B >= 39 bytes, T = 74.80 ms For 0 < B < 14, T = 6.50 + (0.8 * B) ms For B > 13 T = 16.80 ms For 0 < B < 37, T = 1.63 + (0.794 * B) For B > 36, T = 30.2 ms 35.0 ms DC Characteristics (Vcc = 3.0‐3.6 VDC) Symbol Parameter Condition Min Vcc Module Supply Voltage VIL Input Low Voltage All input signals VIH Input High voltage All input signals 2.0 VOL Output Low-Level Voltage Iout = Iout_Max VOH Output High-Level Voltage Iout = Iout_Max IL Input Leakage Current With Pull-up resistors disabled IO1 Output Current IO2 Output Current Typical Max Units 3.0 3.6 -0.3 0.8 5.5 0.4 Vcc-0.4 40 400 nA pins 2, 15 (Dout, ~TX/ Pwr) mA pins 4, 12, 13 (DCD,~CTS,ON/~Sleep) mA 1.5. Mechanical Drawings Figure 1‐04. Mechanical Drawings © 2008 Digi International, Inc. XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 2. RF Module Operation 2.1. Serial Communications The XBee-PRO™ XSC OEM RF Module interfaces to a host device through a CMOS-level asynchronous serial port. Through its serial port, the module can communicate with any UART voltage compatible device or through a level translator to any RS-232/485/422 device. 2.1.1. UART-Interfaced Data Flow Devices that have a UART interface can connect directly through the pins of the XBee‐PRO Module as is shown in the figure below. Figure 2‐01. System Data Flow Diagram in a UART‐interfaced environment (Low‐asserted signals distinguished with horizontal line over signal name.) 3.3V CMOS Logic 3.3V CMOS Logic DI (data in) DI (data in) CTS CTS Microcontroller DO (data out) XStream Module RTS XStream Module DO (data out) Microcontroller RTS 2.1.2. Serial Data Data enters the XBee-PRO Module through the DI pin as an asynchronous serial signal. The signal should idle high when no data is being transmitted. The UART performs tasks, such as timing and parity checking, that are needed for data communications. Serial communication consists of two UARTs configured with compatible parameters (baud rate, parity, start bits, stop bits, data bits) to have successful communication. Each data packet consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit (high). The following figure illustrates the serial bit pattern of data passing through the module. Figure 2‐02. UART data packet 0x1F (decimal number ʺ31ʺ) as transmitted through the XBee‐PRO Module Example Data Format is 8‐N‐1 (bits ‐ parity ‐ # of stop bits) © 2008 Digi International, Inc. 10 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 2.1.3. Flow Control Figure 2‐03. Internal Data Flow Diagram (The five most commonly‐used pin signals shown.) DI (Data In) Buffer and Flow Control When serial data enters the XBee-PRO Module through the DI Pin, then the data is stored in the DI Buffer until it can be transmitted. When the RO parameter threshold is satisfied (refer to Transmit Mode and Command Descriptions sections for more information), the module attempts to initialize an RF connection. If the module is already receiving RF data, the serial data is stored in the module's DI Buffer. If the DI buffer becomes full, hardware or software flow control must be implemented in order to prevent overflow (loss of data between the host and XBee-PRO OEM RF Module). How to eliminate the need for flow control: • Send messages that are smaller than the DI buffer size. The size of the DI buffer varies according to the packet size and parity setting used. • Interface at a lower baud rate (BD parameter) than the fixed RF data rate. Two cases in which the DI Buffer may become full and possibly overflow: • If the serial interface data rate is set higher than the RF data rate of the module, the module will receive data from the host faster than it can transmit the data over-the-air. • If the module is receiving a continuous stream of RF data or if the module is monitoring data on a network, any serial data that arrives on the DI pin is placed in the DI Buffer. The data in the DI buffer will be transmitted over-the-air when the module no longer detects RF data in the network. Hardware Flow Control (CTS). When the DI buffer is 17 bytes away from being full; by default, the module de-asserts (high) CTS to signal to the host device to stop sending data [refer to FT (Flow Control Threshold) and CS (DO2 Configuration) Commands]. CTS is re-asserted after the DI Buffer has 34 bytes of memory available. Software Flow Control (XON). XON/XOFF software flow control can be enabled using the FL (Software Flo DO (Data Out) Buffer and Flow Control DO (Data Out) Buffer and Flow Control When RF data is received, the data enters the DO buffer and is then sent out the serial port to a host device. Once the DO Buffer reaches capacity, any additional incoming RF data is lost. Two cases in which the DO Buffer may become full and possibly overflow: • If the RF data rate is set higher than the interface data rate of the module, the module will receive data from the transmitting module faster than it can send the data to the host. • If the host does not allow the module to transmit data out from the DO buffer because of being held off by hardware or software flow control. Hardware Flow Control (RTS). If RTS is enabled for flow control (RT Parameter = 2), data will not be sent out the DO Buffer as long as RTS (pin 16) is de-asserted. Software Flow Control (XOFF). XON/XOFF software flow control can be enabled using the FL (Software Flow Control) Command. This option only works with ASCII data. © 2008 Digi International, Inc. 11 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 2.2. Modes of Operation XBee-PRO™ XSC RF Modules operate in five modes. Figure 2‐04. Modes of Operation 2.2.1. Idle Mode When not receiving or transmitting data, the RF module is in Idle Mode. The module shifts into the other modes of operation under the following conditions: • Transmit Mode (Serial data is received in the DI Buffer) • Receive Mode (Valid RF data is received through the antenna) • Sleep Mode (Sleep Mode condition is met) • Command Mode (Command Mode Sequence is issued) 2.2.2. Transmit Mode When the first byte of serial data is received from the UART in the DI buffer, the module attempts to shift to Transmit Mode and initiate an RF connection with other modules. Figure 2‐05. Transmission of Data Once in Transmit Mode, the module initializes a communications channel. Channel initialization is the process of sending an RF initializer that synchronizes receiving modules with the transmitting module. When streaming multiple RF packets, the RF Initializer is only sent in front of the first packet. During channel initialization, incoming serial data accumulates in the DI buffer. After the channel is initialized, data in the DI buffer is grouped into packets (up to 64 bytes in each packet) and is transmitted. The module continues to transmit data packets until the DI buffer is empty. Once transmission is finished, the module returns to Idle Mode. This progression is shown in Figure 2-05. As the transmitting module nears the end of the transmission, it inspects the DI buffer to see if more data exists to be transmitted. This could be the case if more bytes arrived from the host after the transmission began. If more data is pending, the transmitting module assembles a subsequent packet for transmission. © 2008 Digi International, Inc. 12 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft RF Packet Figure 2‐06. RF Packet Components * When streaming multiple RF packets, the RF Initializer is only sent in front of the first packet. RF Initializer An RF initializer is sent each time a new connection sequence begins. The RF initializer contains channel information that notifies receiving modules of information such as the hopping pattern used by the transmitting module. The first transmission always sends an RF initializer. An RF initializer can be of various lengths depending on the amount of time determined to be required to prepare a receiving module. For example, a wake-up initializer is a type of RF initializer used to wake remote modules from Sleep Mode (Refer to the FH, LH, HT and SM Commands for more information). The length of the wake-up initializer should be longer than the length of time remote modules are in cyclic sleep. Header The header contains network addressing information that filters incoming RF data. The receiving module checks for a matching VID, Hopping Channel and Destination Address. Data that does not pass through all three network filter layers is discarded. Figure 2‐07. Addressing Layers contained in the Header CRC (Cyclic Redundancy Check) To verify data integrity and provide built-in error checking, a 16-bit CRC (Cyclic Redundancy Check) is computed for the transmitted data and attached to the end of each RF packet. On the receiving end, the receiving module computes the CRC on all incoming RF data. Received data that has an invalid CRC is discarded [See Receive Mode section, next page]. © 2008 Digi International, Inc. 13 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 2.2.3. Receive Mode If a module detects RF data while operating in Idle Mode, the module transitions into Receive Mode to start receiving RF packets. Figure 2‐08. Reception of RF Data After a packet is received, the module checks the CRC (cyclic redundancy check) to ensure that the data was transmitted without error. If the CRC data bits on the incoming packet are invalid, the packet is discarded. If the CRC is valid, the packet proceeds to the DO Buffer. The module returns to Idle Mode after valid RF data is no longer detected or after an error is detected in the received RF data. If serial data is stored in the DI buffer while the module is in Receive Mode, the serial data will be transmitted after the module is finished receiving data and returns to Idle Mode. 2.2.4. Sleep Mode Sleep Modes enable the XBee-PRO Module to operate at minimal power consumption when not in use. Three Sleep Mode options are available: • Pin Sleep • Cyclic Sleep For the module to transition into Sleep Mode, the module must have a non-zero SM (Sleep Mode) Parameter and one of the following must occur: • The module is idle (no data transmission or reception) for a user-defined period of time [Refer to the ST (Time before Sleep) Command]. • SLEEP is asserted (only for Pin Sleep option). In Sleep Mode, the module will not transmit or receive data until the module first transitions to Idle Mode. All Sleep Modes are enabled and disabled using SM Command. Transitions into and out of Sleep Modes are triggered by various events as shown in the table below. Table 2‐01. Summary of Sleep Mode Configurations Sleep Mode Setting Pin Sleep (SM = 1) Cyclic Sleep (SM = 3-8) Transition into Sleep Mode Microcontroller can shut down and wake modules by asserting (high) SLEEP (pin 2). Note: The module will complete a transmission or reception before activating Pin Sleep. Automatic transition to Sleep Mode occurs in cycles as defined by the SM (Sleep Mode) Command. Transition out of Sleep Mode Related Commands Typical Power Consumption De-assert (low) SLEEP (pin 2). SM 50 µA SM, ST, HT, LH, PW 76 µA when sleeping After the cyclic sleep time interval elapses. Note: Module can be Note: The cyclic sleep time interval must be forced into Idle Mode shorter than the “Wake-up Initializer Timer” if PW (Pin Wake-up) Command is issued. (set by LH Command). Pin Sleep (SM = 1) Pin Sleep requires the least amount of power. In order to achieve this state, SLEEP pin must be asserted (high). The module remains in Pin Sleep until the SLEEP pin is de-asserted. After enabling Pin Sleep, the SLEEP pin controls whether the XBee-PRO Module is active or in Sleep Mode. When SLEEP is de-asserted (low), the module is fully operational. When SLEEP is asserted (high), the module transitions to Sleep Mode and remains in its lowest power-consuming state until the SLEEP pin is de-asserted. SLEEP is only active if the module is setup to operate in this mode; otherwise the pin is ignored. © 2008 Digi International, Inc. 14 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Once in Pin Sleep Mode, CTS is de-asserted (high), indicating that data should not be sent to the module. The PWR pin is also de-asserted (low) when the module is in Pin Sleep Mode. Note: The module will complete a transmission or reception before activating Pin Sleep. Cyclic Sleep (SM = 3-8) Cyclic Sleep is the Sleep Mode in which the XBee-PRO Module enters into a low-power state and awakens periodically to determine if any transmissions are being sent. When Cyclic Sleep settings are enabled, the XBee-PRO Module goes into Sleep Mode after a userdefined period of inactivity (no transmission or reception on the RF channel). The user-defined period is determined by ST (Time before Sleep) Command. While the module is in Cyclic Sleep Mode, is de-asserted (high) to indicate that data should not be sent to the module during this time. When the module awakens to listen for data, is asserted and any data received on the DI Pin is transmitted. The PWR pin is also de-asserted (low) when the module is in Cyclic Sleep Mode. The module remains in Sleep Mode for a user-defined period of time ranging from 0.5 seconds to 16 seconds (SM Parameters 3 through 8). After this interval of time, the module returns to Idle Mode and listens for a valid data packet for 100 ms. If the module does not detect valid data (on any frequency), the module returns to Sleep Mode. If valid data is detected, the module transitions into Receive Mode and receives incoming RF packets. The module then returns to Sleep Mode after a Period of inactivity that is determined by ST "Time before Sleep" Command. The module can also be configured to wake from cyclic sleep when SLEEP (pin 2) is de-asserted (low). To configure a module to operate in this manner, PW (Pin Wake-up) Command must be issued. Once SLEEP is de-asserted, the module is forced into Idle Mode and can begin transmitting or receiving data. It remains active until no data is detected for the period of time specified by the ST Command, at which point it resumes its low-power cyclic state. Note: The cyclic interval time defined by SM (Sleep Mode) Command must be shorter than the interval time defined by LH (Wake-up Initializer Timer). For example: If SM=4 (Cyclic 1.0 second sleep), the LH Parameter should equal 0x0B ("1.1" seconds). With these parameters set, there is no risk of the receiving module being asleep for the duration of wake-up initializer transmission. "Cyclic Scanning" explains in further detail the relationship between "Cyclic Sleep" and "Wake-up Initializer Timer" Cyclic Scanning. Each RF transmission consists of an RF Initializer and payload. The wake-up initializer contains initialization information and all receiving modules must wake during the wakeup initializer portion of data transmission in order to be synchronized with the transmitting module and receive the data. Figure 2‐09. Correct Configuration (LH > SM) Length of the wake‐up initializer exceeds the time interval of Cyclic Sleep. The receiver is guaranteed to detect the wake‐up initializer and receive the accompanying payload data. Figure 2‐010.Incorrect Configuration (LH < SM) © 2008 Digi International, Inc. 15 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Length of wake‐up initializer is shorter than the time interval of Cyclic Sleep. This configuration is vulnerable to the receiver waking and missing the wake‐up initializer (and therefore also the accompanying payload data). © 2008 Digi International, Inc. 16 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 2.2.5. Command Mode To modify or read module parameters, the module must first enter into Command Mode, the state in which incoming characters are interpreted as commands. Two command types are available for programming the module: • AT Commands • Binary Commands For modified parameter values to persist in the module registry, changes must be saved to non-volatile memory using WR (Write) Command. Otherwise, parameters are restored to previously saved values after the module is powered off and then on again. AT Commands To Enter AT Command Mode: • Send the 3-character command sequence "+++" and observe guard times before and after the command characters. [refer to ‘Default AT Command Mode Sequence’ below.] The ‘Terminal’ tab (or other serial communications software) of the X-CTU Software can be used to enter the sequence. [OR] • Assert (low) the CONFIG pin and either turn the power going to the module off and back on. (If using a Digi XBIB-R Interface Board, the same result can be achieved by holding the DataIn line low (also known as a break) while rebooting the module by pressing the reset button on the module assembly [module assembly = module mounted to an interface board]). Default AT Command Mode Sequence (for transition to Command Mode): • No characters sent for one second [refer to the BT (Guard Time Before) Command] • Input three plus characters (“+++”) within one second [refer to the CC (Command Sequence Character) Command.] • No characters sent for one second [refer to the AT (Guard Time After) Command.] To Send AT Commands: Send AT commands and parameters using the syntax shown below. Figure 2‐11. Syntax for sending AT Commands To read a parameter value stored in the module register, leave the parameter field blank. The preceding example would change the module’s Destination Address to "0x1F". To store the new value to non-volatile (long term) memory, the Write (ATWR) command must subsequently be sent before powering off the module. System Response. When a command is sent to the module, the module will parse and execute the command. Upon successful execution of a command, the module returns an “OK” message. If execution of a command results in an error, the module returns an “ERROR” message. To Exit AT Command Mode: • If no valid AT Commands are received within the time specified by CT (Command Mode Timeout) Command, the module automatically returns to Idle Mode. [OR] • Send ATCN (Exit Command Mode) Command. For an example of programming the RF module using AT Commands and descriptions of each configurable parameter, refer to the "RF Module Configuration" chapter. © 2008 Digi International, Inc. 17 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Binary Commands Sending and receiving parameter values using binary commands is the fastest way to change operating parameters of the module. Binary commands are used most often to sample signal strength (RS parameter) and/or error counts; or to change module addresses and channels for polling systems when a quick response is necessary. Since the sending and receiving of parameter values takes place through the same data path as 'live' data (received RF payload), interference between the two types of data can be a concern. Common questions regarding the use of binary commands: • What are the implications of asserting CMD while live data is being sent or received? • After sending serial data, is there a minimum time delay before CMD can be asserted? • Is a time delay required after CMD is de-asserted before payload data can be sent? • How to discern between live data and data received in response to a command? CMD (pin 5) must be asserted in order to send binary commands to the module. The CMD pin can be asserted to recognize binary commands anytime during the transmission or reception of data. The status of the CMD signal is only checked at the end of the stop bit as the byte is shifted into the serial port. The application does not allow control over when data is received, except by waiting for dead time between bursts of communication. If the command is sent in the middle of a stream of payload data to be transmitted, the command will essentially be executed in the order it is received. If the radio is continuously receiving data, the radio will wait for a break in the received data before executing the command. The CTS signal will frame the response coming from the binary command request [Figure 2-012]. A minimum time delay of 100 µs (after the stop bit of the command byte has been sent) must be observed before pin 5 can be de-asserted. The command executes after all parameters associated with the command have been sent. If all parameters are not received within 0.5 seconds, the module aborts the command and returns to Idle Mode. Note: When parameters are sent, they are two bytes long with the least significant byte sent first. Binary commands that return one parameter byte must be written with two parameter bytes. Refer to “Programming Examples” section [pXX] for a binary programming example. Commands can be queried for their current value by sending the command logically ORed (bitwise) with the value 0x80 (hexadecimal) with CMD asserted. When the binary value is sent (with no parameters), the current value of the command parameter is sent back through the DO pin. Figure 2‐012.Binary Command Write then Read Signal #4 is CMD (pin 16) Signal #1 is the DIN (pin 3) signal to the radio Signal #2 is the DOUT (pin 2) signal from the radio Signal #3 is CTS (pin 12) In this graph, a value was written to a register and then read out to verify it. While not in the middle of other received data, note that the CTS signal outlines the data response out of the module. IMPORTANT: For the XBee-PRO Module to recognize a binary command, the RT (DI2 Configuration) parameter must be set to one. If binary programming is not enabled (RT ? 1), the module will not recognize that the CMD pin is asserted and therefore will not recognize the data as binary commands. © 2008 Digi International, Inc. 18 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 3. RF Module Configuration 3.1. XBEE-PROProgramming Examples For information about entering and exiting AT and Binary Command Modes, refer to the Command Mode section. 3.1.1. AT Commands To Send AT Commands (Using the ‘Terminal’ tab of the X-CTU Software) Example: Utilize the 'Terminal' tab of the X-CTU Software to change the module's DT (Destination Address) parameter and save the new address to non-volatile memory. This example requires the installation of Digi’s X-CTU Software and a serial connection to a PC. Note: Do not send com‐ mands to the module during flash program‐ ming (when parameters are being written to the module registry). Wait for the ʺOKʺ sys‐ tem response that fol‐ lows the ATWR command before enter‐ ing the next command or use flow control. Select the ‘Terminal’ tab of the X-CTU Software and enter the following command lines: Method 1 (One line per command) Send AT Command +++ ATDTATDT1A0D ATWR ATCN System Response OK (Enter into Command Mode) {current value} (Read Destination Address) OK (Modify Destination Address) OK (Write to non-volatile memory) OK (Exit Command Mode) Method 2 (Multiple commands on one line) Send AT Command +++ ATDT ATDT1A0D,WR,CN System Response OK (Enter into Command Mode) {current value} (Read Destination Address) OK (Execute commands) Note: When using X-CTU Software to program a module, PC com port settings must match the baud (interface data rate), parity & stop bits parameter settings of the module. Use the 'Com Port Setup' section of the “PC Settings” tab to configure PC com port settings to match those of the module. 3.1.2. Binary Commands To Send Binary Commands Example: Use binary commands to change the XBee-PRO Module's destination address to 0x1A0D and save the new address to non-volatile memory. 1. RT Command must be set to "1" in AT Command Mode to enable binary programming. 2. Assert CMD (Pin 16 is driven high). (Enter Binary Command Mode) 3. Send Bytes (parameter bytes must be 2 bytes long): (Send DT (Destination Address) Command) 00 (Least significant byte of parameter bytes 0D (Most significant byte of parameter bytes) 1A (Send WR (Write) Command) 08 De-assert CMD (Pin 16 is driven (Exit Binary Command Mode) 4. low) Note: CTS )is de-asserted high when commands are being executed. Hardware flow control must be disabled as CTS will hold off parameter bytes. © 2008 Digi International, Inc. 19 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 3.2. Command Reference Table Table 3‐01. AT Commands(The RF Module expects numerical values in hexadecimal. ʺdʺ denotes decimal equivalent.)) AT Command Binary Command AT Command Name Range Command Category # Bytes Returned Factory Default AT 0x05 (5d) Guard Time After 0x02 – 0xFFFF [x 100 msec] Command Mode Options 0x0A (10d) Interface Data Rate Standard baud rates: 0–6 Non-standard baud rates: 0x7D – 0xFFFF Serial Interfacing 0x03 9600bps BD 0x15 (21d) BT 0x04 (4d) Guard Time Before 2 – 0xFFFF [x 100 msec] Command Mode Options 0x0A (10d) CC 0x13 (19d) Command Sequence Character 0x20 – 0x7F Command Mode Options 0x2B (“+”) CD 0x28 (40d) DO3 Configuration 0-4 Serial Interfacing CN 0x09 (9d) Exit AT Command Mode Command Mode Options CS 0x1F (31d) DO2 Configuration 0–4 Serial Interfacing CT 0x06 (6d) Command Mode Timeout 0x02 – 0xFFFF [x 100 msec] Command Mode Options 0xC8 (200d) RSSI level in dBm of the most recent packet 0 - 0x70 [read-only] Diagnostics DB DT 0x00 (0d) Destination Address 0 – 0xFFFF Networking E0 0x0A (10d) Echo Off Command Mode Options E1 0x0B (11d) Echo On Command Mode Options ER 0x0F (15d) Receive Error Count 0 – 0xFFFF Diagnostics FH 0x0D (13d) Force Wake-up Initializer Sleep (Low Power) FL 0x07 (7d) Software Flow Control 0–1 Serial Interfacing FR Forces the module to Reset (Special) FT 0x24 (36d) Flow Control Threshold 0 – (DI buffer – 0x11) [bytes] Serial Interfacing varies GD 0x10 (16d) Receive Good Count 0 – 0xFFFF Diagnostics HP 0x11 (17d) Hopping Channel 0–6 Networking HT 0x03 (3d) Time before Wake-up Initializer 0 – 0xFFFF [x 100 msec] Sleep (Low Power) 0xFFFF ID 0x27 (39d) Module VID User settable: 0x10 - 0x7FFF Read-only: 0x8000 – 0xFFFF Networking LH 0x0C (12d) Wake-up Initializer Timer 0 – 0xFF [x 100 msec] Sleep (Low Power) MK 0x12 (18d) Address Mask 0 – 0xFFFF Networking 0xFFFF NB 0x23 (35d) Parity 0–4 Serial Interfacing PC 0x1E (30d) Power-up Mode 0–1 Command Mode Options PW 0x1D (29d) Pin Wake-up 0–1 Sleep (Low Power) RE 0x0E (14d) Restore Defaults (Special) RN 0x19 (25d) Delay Slots 0 – 0xFF [slots] Networking RO 0x21 (33d) Packetization Timeout 0 – 0xFFFF [x 200 µsec] Serial Interfacing RP 0x22 (34d) RSSI PWM Timer 0 - 0x7F [x 100 msec] Diagnostics RR 0x18 (24d) Retries 0 – 0xFF Networking RS 0x1C (28d) RSSI 0x06 – 0x36 [read-only] Diagnostics RT 0x16 (22d) DI2 Configuration 0-2 Serial Interfacing SB 0x36 (54d) Stop Bits 0-1 Serial Interfacing SH 0x25 (37d) Serial Number High 0 – 0xFFFF [read-only] Diagnostics SL 0x26 (38d) Serial Number Low 0 – 0xFFFF [read-only] Diagnostics SM 0x01 (1d) Sleep Mode 0, 1, 3 - 8 Sleep (Low Power) ST 0x02 (2d) Time before Sleep 0x10 – 0xFFFF [x 100 msec] Sleep (Low Power) 0x64 (100d) SY 0x17 (23d) Time before Initialization 0 – 0xFF [x 100 msec] Networking 0 (disabled) TR 0x1B (27d) Transmit Error Count 0 – 0xFFFF Diagnostics TT 0x1A (26d) Streaming Limit 0 – 0xFFFF [0 = disabled] Networking 0xFFFF VR 0x14 (20d) Firmware Version 0 - 0xFFFF [read-only] Diagnostics WR 0x08 (8d) Write (Special) .NOTE: AT Commands issued without a parameter value will return the currently stored parameter. © 2008 Digi International, Inc. 20 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft 3.3. Command Descriptions Commands in this section are listed alphabetically. Command categories are designated between the “< >” symbols that follow each command title. Modules expect numerical values in hexadecimal and those values are designated by a “0x” prefix. Modules operating within the same network should contain the same firmware version. AT (Guard Time After) Command Command Summary AT Command: ATAT Binary Command: 0x05 (5 decimal) Parameter Range:0x02 – 0xFFFF [x 100 milliseconds] Number of bytes returned: 2 Default Parameter Value: 0x0A (10 decimal) Related Commands: BT (Guard Time Before), CC (Command Sequence Character) Description AT Command is used to set the time-ofsilence that follows the command sequence character (CC Command). By default, AT Command Mode will activate after one second of silence. Refer to the AT Commands section [p] to view the default AT Command Mode Sequence. BD (Interface Data Rate) Command Command Summary AT Command: ATBD Binary Command: 0x15 (21 decimal) Parameter Range (Standard baud rates): 0–6 (Non-standard baud rates): 0x7D – 0xFFFF (125d – 65535d) Parameter Value BAUD (bps) Configuration 1200 2400 4800 9600 19200 38400 57600 Number of bytes returned: 2 Default Parameter Value: Set to equal module’s factory-set RF data rate. Description BD Command allows the user to adjust the UART interface data rate and thus modify the rate at which serial data is sent to the module. The new baud rate does not take effect until the CN (Exit AT Command Mode) Command is issued. The RF data rate is not affected by the BD Command. Although most applications will only require one of the seven standard baud rates, non-standard baud rates are also supported. Note: If the serial data rate is set to exceed the fixed RF data rate of the module, flow control may need to be implemented as described in the Pin Signals and Flow Control sections of this manual. Non-standard Interface Data Rates: When parameter values outside the range of standard baud rates are sent, the closest interface data rate represented by the number is stored in the BD register. For example, a rate of 19200 bps can be set by sending the following command line "ATBD4B00". NOTE: When using X-CTU Software, non-standard interface data rates can only be set and read using the X-CTU ‘Terminal’ tab. Nonstandard rates are not accessible through the ‘Modem Configuration’ tab. When the BD command is sent with a non-standard interface data rate, the UART will adjust to accommodate the requested interface rate. In most cases, the clock resolution will cause the stored BD parameter to vary from the parameter that was sent (refer to the table below). Reading the BD command (send "ATBD" command without an associated parameter value) will return the value that was actually stored to the BD register. © 2008 Digi International, Inc. 21 XBee‐PRO™ XSC OEM RF Modules Table 3‐02. Preliminary Draft Parameter Sent vs. Parameter Stored BD Parameter Sent (HEX) 12C E100 Interface Data Rate (bps) 1200 19,200 57600 300 57600 BD Parameter Stored (HEX) 12B E883 BT (Guard Time Before) Command Command Summary AT Command: ATBT Binary Command: 0x04 (4 decimal) Parameter Range:2 – 0xFFFF [x 100 milliseconds] Default Parameter Value: 0x0A (10 decimal) Number of bytes returned: 2 Related Commands: AT (Guard Time After), CC (Command Sequence Character) Description BT Command is used to set the DI pin silence time that must precede the command sequence character (CC Command) of the AT Command Mode Sequence. Refer to the AT Commands section [p] to view the default AT Command Mode Sequence. CC (Command Sequence Character) Command Command Summary AT Command: ATCC Binary Command: 0x13 (19 decimal) Parameter Range: 0x20 – 0x7F Default Parameter Value: 0x2B (ASCII “+” sign) Number of bytes returned: 1 Related Commands: AT (Guard Time After), BT (Guard Time Before) Description CC Command is used to set the ASCII character to be used between Guard Times of the AT Command Mode Sequence (BT+ CC + AT). The AT Command Mode Sequence activates AT Command Mode (from Idle Mode). Refer to the AT Commands section [p] to view the default AT Command Mode Sequence. CD (DO3 Configuration) Command AT Command: ATCD Binary Command: 0x28 (40 decimal) Parameter Range: 0 – 3 Parameter Value Configuration RX LED Default high Default low (reserved) Assert only when packet addressed to module is sent Description CD Command is used to define the behavior of the DO3/RX LED line. Default Parameter Value: 0 Number of bytes returned: 1 © 2008 Digi International, Inc. 22 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft CN (Exit AT Command Mode) Command Command Summary AT Command: ATCN Binary Command: 0x09 (9 decimal) Description CN Command is used to explicitly exit AT Command Mode. CS (DO2 Configuration) Command Command Summary AT Command: ATCS Binary Command: 0x1F (31 decimal) Parameter Range:0 – 4 Parameter Value Configuration RS-232 flow control RS-485 TX enable low high RS-485 TX enable high low Default Parameter Value: 0 Number of bytes returned: 1 Minimum Firmware Version Required: 4.27D Description CS Command is used to select the behavior of the DO2 pin signal. This output can provide RS-232 flow control, control the TX enable signal (for RS485 or RS-422 operations), or set the default level for the I/O line passing function. By default, DO2 provides RS-232 CTS (Clear-to-Send) flow control. CT (Command Mode Timeout) Command Command Summary AT Command: ATCT Binary Command: 0x06 (6 decimal) Parameter Range:0x02 – 0xFFFF [x 100 milliseconds] Default Parameter Value: 0xC8 (200 decimal, 20 seconds) Number of bytes returned: 2 Description CT Command sets the amount of time before AT Command Mode terminates automatically. After a CT time of inactivity, the module exits AT Command Mode and returns to Idle Mode. AT Command Mode can also be exited manually using CN (Exit AT Command Mode) Command. DB (RSSI in dBm) Command Command Summary AT Command: ATDB Binary Command: Not available Parameter Range:00x00 to 0x70 [read-only] Number of bytes returned: returned: 1 Related Commands: RS (RSSI Level) Description DB command returns the signal level of the last packet received in dBm. This reading is useful for determining range characteristics of the Modules under various conditions of noise and distance. Once the command is issued, the module will return the value in dBm. 0x32 (50d) = -50 dBm (strong signal), and 0x64 (100d) = -100 dBm (weak signal). © 2008 Digi International, Inc. 23 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft DT (Destination Address) Command Command Summary AT Command: ATDT Binary Command: 0x00 Parameter Range:0 – 0xFFFF Default Parameter Value: 0 Number of bytes returned: 2 Related Commands: HP (Hopping Channel), ID (Module VID), MK (Address Mask) Description DT Command is used to set the networking address of a Module. Modules use three network layers – Vendor Identification Number (ATID), Channels (ATHP), and Destination Addresses (ATDT). DT Command assigns an address to a module that enables it to communicate only with other modules having the same addresses. All modules that share the same Destination Address can communicate freely with each other. Modules in the same network with a different Destination Address (than that of the transmitter) will listen to all transmissions to stay synchronized, but will not send any of the data out their serial ports. E0 (Echo Off) Command Command Summary AT Command: ATE0 Binary Command: 0x0A (10 decimal) Description E0 Command turns off character echo in AT Command Mode. By default, echo is off. © 2008 Digi International, Inc. 24 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft E1 (Echo On) Command Command Summary AT Command: ATE1 Binary Command: 0x0B (11 decimal) Description E1 Command turns on the echo in AT Command Mode. Each typed character will be echoed back to the terminal when ATE1 is active. E0 is the default. ER (Receive Error Count) Command Command Summary AT Command: ATER Binary Command: 0x0F (15 decimal) Parameter Range:0 – 0xFFFF Default Parameter Value: 0 Number of bytes returned: 2 Related Commands: GD (Receive Good Count) Description Set/Read the receiveerror. The error-count records the number of packets partially received then aborted on a reception error. This value returns to 0 after a reset and is not non-volatile (Value does not persist in the module’s memory after a power-up sequence). Once the “Receive Error Count” reaches its maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count value is explicitly changed or the module is reset. FH (Force Wake-up Initializer) Command Command Summary AT Command: ATFH Binary Command: 0x0D (13 decimal) Description FH Command is used to force a Wake-up Initializer to be sent on the next transmit. WR (Write) Command does not need to be issued with FH Command. Use only with cyclic sleep modes active on remote modules. © 2008 Digi International, Inc. 25 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft FL (Software Flow Control) Command Command Summary AT Command: ATFL Binary Command: 0x07 (7 decimal) Parameter Range: 0 – 1 Parameter Value Default Parameter Value: 0 Number of bytes returned: 1 Configuration Disable software flow control Enable software flow control Description FL Command is used to configure software flow control. Hardware flow control is implemented with the Module as the DO2 pin (), which regulates when serial data can be transferred to the module. FL Command can be used to allow software flow control to also be enabled. XON character used is 0x11 (17 decimal). XOFF character used is 0x13 (19 decimal). FR (Force Reset) Command Command Summary AT Command: ATFR Binary Command: Not available Description FR command is used in order to reset the module through the UART. The characters “OK” will be returned and the module will reset 100ms FT (Flow Control Threshold) Command Command Summary AT Command: ATFT Binary Command: 0x24 (36 decimal) Parameter Range:0 – (DI buffer size minus 0x11 bytes) Default Parameter Value: DI Buffer size minus 0x11 (17 decimal) Number of bytes returned: 2 Minimum Firmware Version Required: 4.27B Description Set/Read the flow control threshold. When FT bytes have accumulated in the DI buffer, CTS is de-asserted or the XOFF software flow control character is transmitted. © 2008 Digi International, Inc. 26 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft GD (Receive Good Count) Command Command Summary AT Command: ATGD Binary Command: 0x10 (16 decimal) Parameter Range:0 – 0xFFFF Default Parameter Value: 0 Number of bytes returned: 2 Related Commands: ER (Receive Error Count) Description Set/Read the count of good received RF packets. Parameter value is reset to 0 after every reset and is not non-volatile (Value does not persist in the module’s memory after a power-up sequence). Once the “Receive Good Count” reaches its maximum value (up to 0xFFFF), it remains at its maximum count value until the maximum count value is manually changed or the module is reset. HP (Hopping Channel) Command Command Summary AT Command: ATHP Binary Command: 0x11 (17 decimal) Parameter Range:0 – 6 Default Parameter Value: 0 Number of bytes returned: 1 Related Commands: DT (Destination Address), ID (Module VID), MK (Address Mask) Description HP Command is used to set the module’s hopping channel number. A channel is one of three layers of addressing available to the module. In order for modules to communicate with each other, the modules must have the same channel number since each network uses a different hopping sequence. Different channels can be used to prevent modules in one network from listening to transmissions of another. © 2008 Digi International, Inc. 27 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft HT (Time before Wake-up Initializer) Command Command Summary AT Command: ATHT Binary Command: 0x03 (3 decimal) Parameter Range:0 – 0xFFFF [x 100 milliseconds] Default Parameter Value: 0xFFFF (means that long wake-up initializer will not be sent) Number of bytes returned: 2 Related Commands: LH (Wake-up Initializer Timer), SM (Sleep Mode), ST (Time before Sleep) Description If any modules within range are running in a “CyclicSleep” setting, a wake-up initializer must be used by the transmitting module for sleeping modules to remain awake [refer to the LH (“Wake-up InitializerTimer”) Command]. When a receiving module in Cyclic Sleep wakes, it must detect the wake-up initializer in order to remain awake and receive data. The value of HT Parameter tells the transmitter, “After a period of inactivity (no transmitting or receiving) lasting HT amount of time, send a long wake-up initializer”. HT Parameter should be set to match the inactivity timeout [specified by ST (Time before Sleep) Command] used by the receiver(s). From the receiving module perspective, after HT time elapses and the inactivity timeout [ST Command] is met, the receiver goes into cyclic sleep. In cyclic sleep, the receiver wakes once per sleep interval to check for a wakeup initializer. When a wake-up initializer is detected, the module will stay awake to receive data. The wake-up initializer must be longer than the cyclic sleep interval to ensure that sleeping modules detect incoming data. When HT time elapses, the transmitter then knows that it needs to send a long Wake-up Initializer for all receivers to be able to remain awake and receive the next transmission. Matching HT to the time specified by ST on the receiving module guarantees that all receivers will detect the next transmission. ID (Modem VID) Command Command Summary AT Command: ATID Binary Command: 0x27 (39 decimal) Parameter Range (user-settable): 0x10 - 0x7FFFF (Factory-set and read-only):0x8000 – 0xFFFF Number of bytes returned: 2 Description Set/Read the “Vendor Identification Number”. Only modems with matching IDs can communicate with each other. Modules with nonmatching VIDs will not receive unintended data transmission. © 2008 Digi International, Inc. 28 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft LH (Wake-up Initializer Timer) Command Command Summary AT Command: ATLH Binary Command: 0x0C (12 decimal) Parameter Range:0 – 0xFF [x 100 milliseconds] Default Parameter Value: 1 Number of bytes returned: 1 Related Commands: HT (Time before Wake-up Initializer), SM (Sleep Mode), ST (Time before Sleep) Description LH Command adjusts the duration of time for which the RF initializer is sent. When receiving modules are put into Cyclic Sleep Mode, they power-down after a period of inactivity [specified by ST (Time before Sleep) Command] and will periodically awaken and listen for transmitted data. In order for the receiving modules to remain awake, they must detect~35ms of the wake-up initializer. LH Command must be used whenever a receiver is operating in Cyclic Sleep Mode. This lengthens the Wake-up Initializer to a specific amount of time (in tenths of a second). The Wake-up Initializer Time must be longer than the cyclic sleep time that is determined by SM (Sleep Mode) Command. If the wake-up initializer time were less than the Cyclic Sleep interval, the connection would be at risk of missing the wake-up initializer transmission. Refer to Figures 3.1 & 3.2 of the SM Command description to view diagrams of correct and incorrect configurations. The images help visualize the importance that the value of LH be greater than the value of SM. MK (Address Mask) Command Command Summary AT Command: ATMK Binary Command: 0x12 (18 decimal) Parameter Range:0 – 0xFFFF Default Parameter Value: 0xFFFF (Destination address (DT parameter) of the transmitting module must exactly match the destination address of the receiving module.) Number of bytes returned: 2 Related Commands: DT (Destination Address), HP (Hopping Channel), ID (Module VID), MY (Source Address) Description MK Command is used to set/read the Address Mask. All data packets contain the Destination Address of the transmitting module. When an RF data packet is received, the transmitter’s Destination Address is logically “ANDed” (bitwise) with the Address Mask of the receiver. The resulting value must match the Destination Address or the Address Mask of the receiver for the packet to be received and sent out the module’s DO serial port. If the “ANDed” value does not match either the Destination Address or the Address Mask of the receiver, the packet is discarded. (All “0” values are treated as “irrelevant” values and are ignored.) © 2008 Digi International, Inc. 29 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft NB (Parity) Command Command Summary AT Command: ATNB Binary Command: 0x23 (35 decimal) Parameter Range:0 – 4 Parameter Value Configuration Description Select/Read parity settings for UART communications. 8-bit (no parity or 7-bit (any parity) 8-bit even 8-bit odd 8-bit mark 8-bit space Default Parameter Value: 0 Number of bytes returned: 1 PC (Power-up to AT Mode) Command Command Summary AT Command: ATPC Binary Command: 0x1E (30 decimal) Parameter Range:0 – 1 Parameter Value Configuration Power-up to Idle Mode Power-up to AT Command Mode Default Parameter Value: 0 Number of bytes returned: 1 Description PC Command allows the module to power-up directly into AT Command Mode from reset or power-on. If PC Command is enabled with SM Parameter set to 1, DI3 (pin 2) can be used to enter the module into AT Command Mode. When the DI3 pin is deasserted (low), the module will wakeup in AT Command Mode. This behavior allows module DTR emulation. © 2008 Digi International, Inc. 30 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft PW (Pin Wake-up) Command Command Summary AT Command: ATPW Binary Command: 0x1D (29 decimal) Parameter Range:0 – 1 Parameter Value Configuration Disabled Enabled Default Parameter Value: 0 Number of bytes returned: 1 Related Commands: SM (Sleep Mode), ST (Time before Sleep) Minimum Firmware Version Required: 4.22 Description Under normal operation, a module in Cyclic Sleep Mode cycles from an active state to a low-power state at regular intervals until data is ready to be received. If the PW Parameter is set to 1, SLEEP (pin 2) can be used to wake the module from Cyclic Sleep. If the SLEEP pin is de-asserted (low), the module will be fully operational and will not go into Cyclic Sleep. Once SLEEP is asserted, the module will remain active for the period of time specified by ST (Time before Sleep) Command, and will return to Cyclic Sleep Mode (if no data is ready to be transmitted). PW Command is only valid if Cyclic Sleep has been enabled. RE (Restore Defaults) Command Command Summary AT Command: ATRE Binary Command: 0x0E (14 decimal) Description RE Command restores all configurable parameters to factory default settings. However, RE Command will not write the default values to non-volatile (persistent) memory. Unless the WR (Write) Command is issued after the RE command, the default settings will not be saved in the event of module reset or power-down. RN (Delay Slots) Command Command Summary AT Command: ATRN Binary Command: 0x19 (25 decimal) Parameter Range:0 – 0xFF [slots] Default Parameter Value: 0 (no delay slots inserted) Number of bytes returned: 1 Description RN Command is only applicable if retries have been enabled [RR (Retries) Command], or if forced delays will be inserted into a transmission [refer to TT (Streaming Limit) Command]. RN Command is used to adjust the time delay that the transmitter inserts before attempting to resend a packet. If the transmitter fails to receive an acknowledgement after sending a packet, it will insert a random number of delay slots (ranging from 0 to (RN minus 1)) before attempting to resend the packet. Each delay slot lasts for a period of 38ms. If two modules attempted to transmit at the same time, the random time delay after packet failure would allow one of the two modules to transmit the packet successfully, while the other would wait until the channel opens up to begin transmission. © 2008 Digi International, Inc. 31 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft RO (Packetization Timeout) Command Command Summary AT Command: ATRO Binary Command: 0x21 (33 decimal) Parameter Range:0 – 0xFFFF [x 200 µs] Default Parameter Value: 0 Number of bytes returned: 2 Minimum Firmware Version Required: 4.2AA Description RO Command is used to specify/read the time of silence (no bytes received) after which transmission begins. After a serial byte is received and if no other byte is received before the RO timeout, the transmission will start. RP (RSSI PWM Timer) Command Command Summary AT Command: ATRP Binary Command: 0x22 (34 decimal) Parameter Range:0 - 0x7F [x 100 milliseconds] Default Parameter Value: 0 (disabled) Number of bytes returned: 1 Table 3‐03. Description RP Command is used to enable a PWM (“Pulse Width Modulation”) output on the Config pin which is calibrated to show the level the received RF signal is above the sensitivity level of the module. The PWM pulses vary from zero to 95 percent. Zero percent means the received RF signal is at or below the published sensitivity level of the module. The following table shows levels above sensitivity and PWM values. The total period of the PWM output is 8.32 ms. There are 40 steps in the PWM output and therefore the minimum step size is 0.208 ms. PWM Chart dBm above Sensitivity 10 20 30 PWM percentage (high period / total period) 47.5 % 62.5 % 77.5 % A non-zero value defines the time that the PWM output will be active with the RSSI value of the last received RF packet. After the set time when no RF packets are received, the PWM output will be set low (0 percent PWM) until another RF packet is received. The PWM output will also be set low at power-up. A parameter value of 0xFF permanently enables the PWM output and it will always reflect the value of the last received RF packet. PWM output shares the Config input pin. When the module is powered, the Config pin will be an input. During the power-up sequence, the Config pin will be read to determine whether the module is going into AT Command Mode. After this, if RP parameter is a non-zero value, the Config pin will be configured as an output and set low until the first RF packet is received. With a non-zero RP parameter, the Config pin will be an input for RP ms after power up. © 2008 Digi International, Inc. 32 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft RR (Retries) Command Command Summary AT Command: ATRR Binary Command: 0x18 (24 decimal) Parameter Range:0 – 0xFF Default Parameter Value: 0 (disabled) Number of bytes returned: 1 Description Networking> RR Command specifies the number of retries that can be sent for a given RF packet. Once RR Command is enabled (set to a non-zero value), RF packet acknowledgements and retries are enabled. After transmitting a packet, the transmitter will wait to receive an acknowledgement from a receiver. If the acknowledgement is not received in the period of time specified by the RN (Delay Slots) Command, the transmitter will transmit the original packet again. The packet will be transmitted repeatedly until an acknowledgement is received or until the packet has been sent RR times. Note: For retries to work correctly, all modules in the system must have retries enabled. RS (RSSI) Command Command Summary AT Command: ATRS Binary Command: 0x1C (28 decimal) Parameter Range: 0x06 – 0x36 [readonly] Number of bytes returned: 1 Description RS Command returns the signal level of the last packet received. This reading is useful for determining range characteristics of the modules under various conditions of noise and distance. Once the command is issued, the module will return a value between 0x6 and 0x36 where 0x36 represents a very strong signal level and 0x4 indicates a low signal level. © 2008 Digi International, Inc. 33 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft RT (DI2 Configuration) Command Command Summary AT Command: ATRT Binary Command: 0x16 (22 decimal) Parameter Range:0 – 2 Parameter Value Configuration disabled Enable Binary Programming Enable Default Parameter Value: 0 Number of bytes returned: 1 Flow Control Description RT command is used to dictate the behavior of the DI2/RTS/CMD line. RT Command must be issued to enable RTS flow control or binary programming. SB (Stop Bits) Command Command Summary AT Command: ATSB Binary Command: 0x36 (54 decimal) Parameter Range:0 – 1 Parameter Value Configuration Description SB Command is used to set/read the number of stop bits in the data packets. 1 stop bits 2 stop bits Default Parameter Value: 0 Number of bytes returned: 1 SH (Serial Number High) Command Command Summary AT Command: ATSH Binary Command: 0x25 (37 decimal) Parameter Range:0 – 0xFFFF [read-only] Number of bytes returned: 2 Related Commands: SL (Serial Number Low) Description Set/Read the serial number high word of the module. SL (Serial Number Low) Command Command Summary AT Command: ATSH Binary Command: 0x26 (38 decimal) Parameter Range:0 – 0xFFFF [read-only] Number of bytes returned: 2 Related Commands: SH (Serial Number High) Description Set/Read the serial number low word of the module. © 2008 Digi International, Inc. 34 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft SM (Sleep Mode) Command Command Summary AT Command: ATSM Binary Command: 0x01 Parameter Range:0,1 3-8 Parameter Value Configuration Disabled Pin Sleep Cyclic 0.5 second sleep (Module wakes every 0.5 seconds) Cyclic 1.0 second sleep Cyclic 2.0 second sleep Cyclic 4.0 second sleep Cyclic 8.0 second sleep Cyclic 16.0 second sleep Default Parameter Value: 0 Number of bytes returned: 1 Related Commands: Description SM Command is used to adjust Sleep Mode settings. By default, Sleep Mode is disabled and the module remains continually active. SM Command allows the module to run in a lower-powerstate and be configured in one of eight settings. Cyclic Sleep settings wake the module after the amount of time designated by SM Command. If the module detects a wake-up initializer during the time it is awake, it will synchronize with the transmitter and start receiving data after the wake-up initializer runs its duration. Otherwise, it returns to Sleep Mode and continue to cycle in and out of inactivity until the Wake-up Initializer is detected. If a Cyclic Sleep setting is chosen, the ST, LH and HT parameters must also be set as described in the “Sleep Mode” section of this manual. For Pin Sleep – PC (Power-up Mode), PW (Pin Wake-up) For Serial Port Sleep – ST (Time before Sleep) For Cyclic Sleep – ST (Time before Sleep), LH (Wake-up Initializer Timer), HT (Time Before Wake-up Initializer), PW (Pin Wakeup) ST (Time before Sleep) Command Command Summary AT Command: ATST Binary Command: 0x02 Parameter Range:0x10 – 0xFFFF [x 100 milliseconds] Default Parameter Value: 0x64 (100 decimal) Number of bytes returned: 2 Related Commands: SM (Sleep Mode), LH (Wake-up Initializer Timer), HT (Time before Wake-up Initializer) Description ST Command sets the period of time (in tenths of seconds) in which the module remains inactive before entering into Sleep Mode. For example, if the ST Parameter is set to 0x64 (100 decimal), the module will enter into Sleep mode after 10 seconds of inactivity (no transmitting or receiving). This command can only be used if Cyclic Sleep or Serial Port Sleep Mode settings have been selected using SM (Sleep Mode) Command. © 2008 Digi International, Inc. 35 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft SY (Time before Initialization) Command Command Summary AT Command: ATSY Binary Command: 0x17 (23 decimal) Parameter Range:0 – 0xFF [x 100 milliseconds] Default Parameter Value: 0 (Disabled channel initialization information is sent with each RF packet.) Number of bytes returned: 1 Description SY Command keeps a communication channel open as long as module transmits or receives before the active connection expires. It can be used to reduce latency in a query/ response sequence and should be set 100 ms longer than the delay between transmissions. This command allows multiple Modules to share a hopping channel for a given amount of time after receiving data. By default, all packets include an RF initializer that contains channel information used to synchronize any listening receivers to the transmitter’s hopping pattern. Once a new module comes within range, it is able to instantly synchronize to the transmitter and start receiving data. If no new modules are introduced into the system, the synchronization information becomes redundant once modules have become synchronized. SY Command allows the modules to remove this information from the RF Initializer after the initial synchronization. For example, changing the SY Parameter to 0x14 (20 decimal) allows all modules to remain in sync for 2 seconds after the last data packet was received. Synchronization information is not re-sent unless transmission stops for more than 2 seconds. This command allows significant savings in packet transmission time. Warning: Not recommended for use in an interference-prone environment. Interference can break up the session and the communications channel will not be available again until SY time expires. With SY set to zero, the channel session is opened and closed with each transmission - resulting in a more robust link with more latency. TR (Transmit Error Count) Command Command Summary AT Command: ATTR Binary Command: 0x1B (27 decimal) Parameter Range:0 – 0xFFFF Default Parameter Value: 0 Number of bytes returned: 2 Related Commands: RR (Retries) Description TR Command records the number of retransmit failures. This number is incremented each time a packet is not acknowledged within the number of retransmits specified by the RR (Retries) Command. It therefore counts the number of packets that were not successfully received and have been dropped. The TR Parameter is not non-volatile and will therefore be reset to zero each time the module is reset. © 2008 Digi International, Inc. 36 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft TT (Streaming Limit) Command Command Summary AT Command: ATTT Binary Command: 0x1A (26 decimal) Parameter Range:0 – 0xFFFF (0 = disabled) Default Parameter Value: 0xFFFF (65535 decimal) Number of bytes returned: 2 Related Commands: RN (Delay Slots) Description TT Command defines a limit on the number of bytes that can be sent out before a random delay is issued. TT Command is used to simulate full-duplex behavior. If a module is sending a continuous stream of RF data, a delay is inserted which stops its transmission and allows other modules time to transmit (once it sends number of bytes specified by TT Command). Inserted random delay lasts between 1 & ‘RN + 1’ delay slots, where each delay slot lasts 38 ms. © 2008 Digi International, Inc. 37 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Appendix A: Agency Certifications FCC (United States) Certification The XBee-PRO™ XSC OEM RF Module complies with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required. In order to operate under Digi’s FCC Certification, OEMs/integrators must comply with the following regulations: 1. The system ntegrator must ensure that the text provided with this device [Figure A-01] is placed on the outside of the final product and within the final product operation manual. 2. The XBee-PRO™ XSC OEM RF Module may only be used with antennas that have been tested and approved for use with this module [refer to to Table A-1. Labeling Requirements WARNING: The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product enclosure that displays the text shown in the figure below. Figure A‐01. Required FCC Label for OEM products containing the XBee‐PRO™ XSC OEM RF Module Contains FCC ID: MCQ-XBEEXSC The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept any interference received, including interference that may cause undesired operation. FCC Notices IMPORTANT: The XBee-PRO™ XSC OEM RF Module has been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Modifications not expressly approved by Digi could void the user's authority to operate the equipment. IMPORTANT: OEMs must test final product to comply with unintentional radiators (FCC section 15.107 & 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules. IMPORTANT: The RF module has been certified for remote and base radio applications. If the module will be used for portable applications, the device must undergo SAR testing. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect equipment and receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician for help. Limited Modular Approval This is an RF module approved for Limited Modular use operating as a mobile transmitting device with respect to section 2.1091 and is limited to OEM installation for Mobile and Fixed applications only. During final installation, end-users are prohibited from access to any programming parameters. Professional installation adjustment is required for setting module power and antenna gain to meet EIRP compliance for high gain antenna(s). © 2008 Digi International, Inc. 33 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Final antenna installation and operating configurations of this transmitter including antenna gain and cable loss must not exceed the EIRP of the configuration used for calculating MPE. Grantee (Digi) must coordinate with OEM integrators to ensure the end-users and installers of products operating with the module are provided with operating instructions to satisfy RF exposure requirements. The FCC grant is valid only when the device is sold to OEM integrators. Integrators are instructed to ensure the end-user has no manual instructions to remove, adjust or install the device. FCC-approved Antennas WARNING: This device has been tested with Reverse Polarity SMA connectors with the antennas listed in the tables of this section. When integrated into OEM products, fixed antennas require installation preventing end-users from replacing them with nonapproved antennas. Antennas not listed in the tables must be tested to comply with FCC Section 15.203 (unique antenna connectors) and Section 15.247 (emissions). Fixed Base Station and Mobile Applications Digi RF Modules are pre-FCC approved for use in fixed base station and mobile applications. When the antenna is mounted at least 20cm (8") from nearby persons, the application is considered a mobile application. Portable Applications and SAR Testing When the antenna is mounted closer than 20cm to nearby persons, then the application is considered "portable" and requires an additional test be performed on the final product. This test is called Specific Absorption Rate (SAR) testing and measures the emissions from the module and how they affect the person. RF Exposure This statement must be included as a CAUTION statement in OEM product manuals. WARNING: This equipment is approved only for mobile and base station transmitting devices. Antenna(s) used for this transmitter must be installed to provide a separation distance of at least 30 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. NOTE: The separation distance indicated in the above is 30 cm, but any distance greater than or equal to 23 cm can be used (per MPE evaluation). IC (Industry Canada) Certification Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text: Contains Model XBEE-PRO XSC Radio (900 MHz), IC: 1846A-XBEE-PRO XSC Integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accepts FCC test report or CISPR 22 test report for compliance with ICES-003. Transmitter Antennas This device has been designed to operate with the antennas listed below, and having a maximum gain of 15.1 dB. Antennas not included in this list or having a gain greater than 15.1 dB are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication © 2008 Digi International, Inc. 34 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Antenna Options (1-watt transmit power output or lower): 900 MHz Antenna Listings Table A-01. Antennas approved for use with the XBee-PRO XSC OEM RF Module Part Number Type Connector Gain Application A09-F0 Fiberglass Base A09-F1 Fiberglass Base RPN 0 dBi Fixed RPN 1.0 dBi Fixed A09-F2 A09-F3 Fiberglass Base RPN 2.1 dBi Fixed Fiberglass Base RPN 3.1 dBi Fixed A09-F4 Fiberglass Base RPN 4.1 dBi Fixed A09-F5 Fiberglass Base RPN 5.1 dBi Fixed A09-F6 Fiberglass Base RPN 6.1 dBi Fixed A09-F7 Fiberglass Base RPN 7.1 dBi Fixed A09-F8 Fiberglass Base RPN 8.1 dBi Fixed Omni-directional antennas A09-F9 Base Station RPSMAF 9.2dBi Fixed A09-W7 Wire Base Station RPN 7.1 dBi Fixed A09-F0 Fiberglass Base RPSMA 0 dBi Fixed A09-F1 Fiberglass Base RPSMA 1.0 dBi Fixed A09-F2 Fiberglass Base RPSMA 2.1 dBi Fixed A09-F3 Fiberglass Base RPSMA 3.1 dBi Fixed A09-F4 Fiberglass Base RPSMA 4.1 dBi Fixed A09-F5 Fiberglass Base RPSMA 5.1 dBi Fixed A09-F6 Fiberglass Base RPSMA 6.1 dBi Fixed A09-F7 Fiberglass Base RPSMA 7.1 dBi Fixed A09-F8 Fiberglass Base RPSMA 8.1 dBi Fixed A09-M7 Base Station RPSMAF 7.2dBi Fixed A09-W7SM Wire Base Station RPSMA 7.1 dBi Fixed A09-F0TM Fiberglass Base RPTNC 0 dBi Fixed A09-F1TM Fiberglass Base RPTNC 1.0 dBi Fixed A09-F2TM Fiberglass Base RPTNC 2.1 dBi Fixed A09-F3TM Fiberglass Base RPTNC 3.1 dBi Fixed A09-F4TM Fiberglass Base RPTNC 4.1 dBi Fixed A09-F5TM Fiberglass Base RPTNC 5.1 dBi Fixed A09-F6TM Fiberglass Base RPTNC 6.1 dBi Fixed A09-F7TM Fiberglass Base RPTNC 7.1 dBi Fixed A09-F8TM Fiberglass Base RPTNC 8.1 dBi Fixed A09-W7TM Wire Base Station RPTNC 7.1 dBi Fixed A09-HSM-7 Straight half-wave RPSMA 3.0 dBi Fixed / Mobile A09-HASM-675 Articulated half- RPSMA 2.1 dBi Fixed / Mobile A09-HABMM-P6I Articulated half- MMCX 2.1 dBi Fixed / Mobile A09-HABMM-6-P6I Articulated half- MMCX 2.1 dBi Fixed / Mobile A09-HBMM-P6I Straight half-wave MMCX 2.1 dBi Fixed / Mobile A09-HRSM Right angle half- RPSMA 2.1 dBi Fixed A09-HASM-7 Articulated half- RPSMA 2.1 dBi Fixed A09-HG Glass mounted RPSMA 2.1 dBi Fixed A09-HATM Articulated half- RPTNC 2.1 dBi Fixed A09-H Half-wave dipole RPSMA 2.1 dBi Fixed A09-HBMMP6I 1/2 wave antenna MMCX 2.1dBi Mobile © 2008 Digi International, Inc. 35 XBee‐PRO™ XSC OEM RF Modules A09-QBMMP6I Preliminary Draft MMCX 1.9 dBi Mobile Integrated 1.9 dBi Mobile 29000187 1/4 wave antenna 1/4 wave integrated wire antenna Helical Integrated -2.0 dBi Fixed/Mobile A09-QW Quarter-wave wire Permanent 1.9 dBi Fixed / Mobile A09-QRAMM 3 “ Quarter-wave MMCX 2.1 dBi Fixed / Mobile A09-QI A09-QSM-3 Quarter-wave RPSMA 1.9 dBi Fixed / Mobile A09-QSM-3H Heavy duty quarter- RPSMA 1.9 dBi Fixed / Mobile A09-QBMM-P6I Quarter-wave w/ 6” MMCX 1.9 dBi Fixed / Mobile A09-QHRN Miniature Helical Permanent -1 dBi Fixed / Mobile A09-QHSN Miniature Helical Permanent -1 dBi Fixed / Mobile A09-QHSM-2 2” Straight RPSMA 1.9 dBi Fixed / Mobile A09-QHRSM-2 2" Right angle RPSMA 1.9 dBi Fixed / Mobile A09-QHRSM-170 1.7" Right angle RPSMA 1.9 dBi Fixed / Mobile A09-QRSM-380 3.8" Right angle RPSMA 1.9 dBi Fixed / Mobile A09-QAPM-520 5.2” Articulated Permanent 1.9 dBi Fixed / Mobile A09-QSPM-3 3” Straight screw Permanent 1.9 dBi Fixed / Mobile A09-QAPM-3 3” Articulated screw Permanent 1.9 dBi Fixed / Mobile A09-QAPM-3H 3” Articulated screw Permanent 1.9 dBi Fixed / Mobile A09-DPSM-P12F omni directional RPSMA 3.0 dBi Fixed A09-D3NF-P12F omni directional RPN 3.0 dBi Fixed A09-D3SM-P12F omni directional w/ RPSMA 3.0 dBi Fixed A09-D3PNF omni directional RPN 3.0 dBi Fixed A09-D3TM-P12F omni directional w/ RPTNC 3.0 dBi Fixed A09-D3PTM omni directional RPTNC 3.0 dBi Fixed A09-M0SM Mag Mount RPSMA 0 dBi Fixed A09-M2SM Mag Mount RPSMA 2.1 dBi Fixed A09-M3SM Mag Mount RPSMA 3.1 dBi Fixed A09-M5SM Mag Mount RPSMA 5.1 dBi Fixed A09-M7SM Mag Mount RPSMA 7.1 dBi Fixed A09-M8SM Mag Mount RPSMA 8.1 dBi Fixed A09-M0TM Mag Mount RPTNC 0 dBi Fixed A09-M2TM Mag Mount RPTNC 2.1 dBi Fixed A09-M3TM Mag Mount RPTNC 3.1 dBi Fixed A09-M5TM Mag Mount RPTNC 5.1 dBi Fixed A09-M7TM Mag Mount RPTNC 7.1 dBi Fixed A09-M8TM Mag Mount RPTNC 8.1 dBi Fixed A09-Y6 2 Element Yagi RPN 6.1 dBi Fixed / Mobile A09-Y7 3 Element Yagi RPN 7.1 dBi Fixed / Mobile A09-Y8 4 Element Yagi RPN 8.1 dBi Fixed / Mobile A09-Y9 4 Element Yagi RPN 9.1 dBi Fixed / Mobile A09-Y10 5 Element Yagi RPN 10.1 dBi Fixed / Mobile Yagi antennas A09-Y11 6 Element Yagi RPN 11.1 dBi Fixed / Mobile A09-Y12 7 Element Yagi RPN 12.1 dBi Fixed / Mobile A09-Y13 9 Element Yagi RPN 13.1 dBi Fixed / Mobile A09-Y14 10 Element Yagi RPN 14.1 dBi Fixed / Mobile A09-Y14 12 Element Yagi RPN 14.1 dBi Fixed / Mobile © 2008 Digi International, Inc. 36 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft A09-Y15 13 Element Yagi RPN 15.1 dBi Fixed / Mobile A09-Y15 15 Element Yagi RPN 15.1 dBi Fixed / Mobile A09-Y6TM 2 Element Yagi RPTNC 6.1 dBi Fixed / Mobile A09-Y7TM 3 Element Yagi RPTNC 7.1 dBi Fixed / Mobile A09-Y8TM 4 Element Yagi RPTNC 8.1 dBi Fixed / Mobile A09-Y9TM 4 Element Yagi RPTNC 9.1 dBi Fixed / Mobile A09-Y10TM 5 Element Yagi RPTNC 10.1 dBi Fixed / Mobile A09-Y11TM 6 Element Yagi RPTNC 11.1 dBi Fixed / Mobile A09-Y12TM 7 Element Yagi RPTNC 12.1 dBi Fixed / Mobile A09-Y13TM 9 Element Yagi RPTNC 13.1 dBi Fixed / Mobile A09-Y14TM 10 Element Yagi RPTNC 14.1 dBi Fixed / Mobile A09-Y14TM 12 Element Yagi RPTNC 14.1 dBi Fixed / Mobile A09-Y15TM 13 Element Yagi RPTNC 15.1 dBi Fixed / Mobile A09-Y15TM 15 Element Yagi RPTNC 15.1 dBi Fixed / Mobile © 2008 Digi International, Inc. 37 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Appendix B: Additional Information 5-Year Warranty WARRANTY PERIOD: Digi warranties hardware Product for a period of five (5) years. WARRANTY PROCEDURE: Upon return of the hardware Product Digi will, at its option, repair or replace Product at no additional charge, freight prepaid, except as set forth below. Repair parts and replacement Product will be furnished on an exchange basis and will be either reconditioned or new. All replaced Product and parts become the property of Digi. If Digi determines that the Product is not under warranty, it will, at the Customers option, repair the Product using current Digi standard rates for parts and labor, and return the Product UPS Ground at no charge in or out of warranty. Ordering Information Figure B‐01. Module Part Number Matrix 1 Product Family XB = XBee 2 Power / Range P = PRO Not used = Regular 3 Frequency 09 = 900 MHz 24 = 2.4 GHz H9 = 915 MHz (Australia) 08 = 868 MHz (Europe) 4 Protocol A = 802.15.4 (Series 1) B = ZNet 2.5 (Series 2) DM = DigiMesh DP = Digi Point to Multipoint © 2008 Digi International, Inc. 38 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft XC = XStream Compatible Z6 = ZigBee 2006 Z7 = ZigBee 2007 WF = WiFi (802.11) 5 Antenna Type C = Chip H = Helical S = SMA U = U.FL W = Wire N = None 6 Temperature Rating C = Commercial I = Industrial T = Tested 7 Mount T = Through-hole S = Surface Mount (Not used currently) Not used for XBee 802.15.4 (Series 1) 8 Variation Baud, Firmware, Customer Specific Settings When Protocol = DM, DP and XC 001 = 1200 bps 009 = 9600 bps 019 = 19200 bps 156 = 156000 bps When Protocol = A, B, Z6 and Z7 001 = standard firmware for XBee 802.15.4 (Series 1) 004 = Router, AT for XBee ZNet2.5 (Series 2) other firmware settings as needed J at the end = Japan certified version © 2008 Digi International, Inc. 39 XBee‐PRO™ XSC OEM RF Modules Preliminary Draft Contact Digi For the best in wireless data solutions and support, please use the following resources: Technical Support: Phone. (866) 765-9885 toll-free U.S.A. & Canada (801) 765-9885 Worldwide Live Chat. www.digi.com E-Mail. support @digi.com Office hours are 8:00 am - 5:00 pm [U.S. Mountain Time] © 2008 Digi International, Inc. 40
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : FrameMaker 7.2 Modify Date : 2008:02:26 09:18:54-05:00 Create Date : 2008:02:25 13:56:35Z Metadata Date : 2008:02:26 09:18:54-05:00 Format : application/pdf Title : manual_xs_oem_rf-module_v42b5.book Creator : bpariso Producer : Acrobat Distiller 8.0.0 (Windows) Document ID : uuid:163b5788-0938-47d4-b55e-ca21125a7116 Instance ID : uuid:1f012864-b36c-4c29-8208-a1e07d7e7a70 Page Count : 45 Author : bparisoEXIF Metadata provided by EXIF.tools