Leland Legacy Sample Pump
High Flows, Long Runs Enhance Measurement Sensitivity!
Flows: 5 to 15 L/min

Certifications
Charging port

performance
verified

Secure belt clip
Data port
Protective inlet filter
Protective cover
Bright status LED
Top view
8 inches

Leland Legacy® is the perfect partner for the Sioutas Impactor

3.9 inches

 High flows — 5 to 15 L/min
• Provides the high flows and long run times of a vacuum-style pump in
a compact, portable, battery-operated sampler within specified back
pressure range

 CalChek automatic calibration feature
• Provides hands-free direct communication to a Defender calibrator

 Adjustable datalogging interval from 3 seconds to 8 hours
with DataTrac Software

 Designed for use with impactors, spore traps, 37-mm filters,
low-volume PUF tubes, and other low-pressure applications†

 Rugged and convenient case design

 Long 24-hour runs on one charge with Li-Ion battery

• Tough rubber overmolding protects the pump and
provides a sure grip
• Anti-static thermoplastic material
• Inlet port with removable protective cover
• Easy-access computer interface and battery charging jack under
protective cover

• Suitable for unattended ambient air sampling

 Low noise, size, and weight
• Ideal for indoor air studies or unattended ambient air sampling

 Longer runs + Higher flows = Enhanced sensitivity for
measuring low concentrations

 Performance with Sioutas Impactor verified by EPA-ETV

 Patented* highly accurate isothermal flow control system

 Featured in deployable sampler systems

 Flexible programming options

 CE marked

• Manual three-button programmability using the large built-in keypad
• PC programmability with DataTrac Software for Leland Legacy
– Create complete running sequences, download sampling history,
and generate exposure reports for ISO 9000 or quality programs

* U.S. Patent No. 5,892,160
† Leland Legacy is not recommended for high back pressure applications such as asbestos
clearance sampling.

 Large easy-to-read LCD
• Displays battery status indicator, flow fault,
run time data, and sampling parameters

SKC Inc. 724-941-9701

SKC-West 714-992-2780

SKC Gulf Coast 281-859-8050

www.skcinc.com

SKC South 434-352-7149

Quick View
Leland Legacy Sample Pump
Performance Profile
Flow Rate Accuracy
Timing Accuracy
Atmospheric Pressure Accuracy
Typical Run Time

Charge Time
(varies with battery capacity
and level of discharge)
Temperature Range
Altitude
Timer Display Range
Time Display
Volume Display
Noise Level
Flow Fault
Flow Control

Weight

± 5% of set-point after calibration
1 min/mo at 25 C
± 3% in Hg
Battery: 24 hrs at 9 L/min with Sioutas Impactor (approx. 13 in water back pressure)
24 hrs at 5 L/min with low-volume PUF tube
24 hrs at 10 L/min with IMPACT Sampler in DPS System
24 hrs at 8 L/min with 8 L/min Respirable PPI
Using charger with AC power: Extended run times
15 hrs with approved charger
Operating: 32 to 104 F (0 to 40 C)
Storage: -4 to 95 F (-20 to 35 C)
Charging: 32 to 113 F (0 to 45 C)
The pump can apply correction to volumetric flow during sampling for weather-related or
altitude variations from the atmospheric pressure established at calibration up to at least
7500 feet above and 5000 feet below sea level.
1 to 99999 min (69 days); if run time exceeds 69 days, timer display rolls over
Time of day in hours and minutes (12 or 24-hr clock) with AM and PM indicators
Continually updated based on corrected flow rate multiplied by sampling time
When volume exceeds 99,999 liters, the pump will continue to run normally but an O_FLO
Error will appear on the LCD.
62.5 dBA‡ - pump without case
52 dBA‡ - pump housed in noise-reducing case (optional accessory)
After 15 sec, pump goes into Hold, retains accumulated run time and historical data, and
displays fault icon. Auto-restart is attempted every 20 sec up to 10 times (adjustable with
DataTrac Software)
An internal isothermal flow sensor measures flow directly and continuously. Sensor readings
are used in a flow monitoring algorithm to maintain calibrated volumetric flow. In addition, builtin atmospheric temperature and pressure sensors provide readings to correct volumetric flow
for these parameters when they vary from point of calibration.
36 oz (1 kg)

‡ Measured 3 feet (1 meter) from pump operating at 10 L/min and 12 inches water back pressure

Ordering Information
Leland Legacy requires 3/8-inch ID tubing.
Pump and Kits
Leland Legacy Pump** with Li-Ion battery pack and screwdriver set, requires charger
Starter Kit includes pump, single charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip
with cable tie
Single Pump Kit**# includes Leland Legacy pump and single charger, in a Pelican carry case
5-pack Pump Kit**# includes 5 Leland Legacy pumps, Take Charge 5 Multi-charger, and
DataTrac Software, in a deluxe Pelican case
Accessories
TSI 4146 Calibration Kit, flow measurement from 0.01 to 20 L/min, includes calibrator, soft-side
case, mounting lugs, 1/4-inch ID tubing, battery pack, 6 AA batteries, inlet filter, dampening module,
NIST certificate, and manual
Chargers
Single
Take Charge 5 Multi-charger
CalChek Communication Cable, required for CalChek calibration
Replacement Parts
Replacement Battery Pack,** Li-Ion
Replacing batteries with non-approved battery packs voids any warranty.
Replacement Filter/O-ring Set, 5 filters and 1 O-ring
Replacement Inlet Filters, pk/50

Cat. No.
100-3002
100-240 V
100-240 V

100-3002-S
100-3002K

100-240 V

100-3002K5

740-4146
100-240 V
100-240 V

223-241
223-441
210-502

P75692
P40021B
P40021A

** Leland Legacy pumps contain Li-Ion batteries and may be subject to special shipping regulations.

SKC Limited Warranty and Return Policy
SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability and the buyer’s
exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to http://www.skcinc.com/warranty.asp.

SKC Inc. 724-941-9701

SKC-West 714-992-2780

SKC Gulf Coast 281-859-8050

www.skcinc.com

Flow Rate (ml/min)
5 to 15 (L/min)
Weight in Ounces (grams)
36 (1000)
Compensation Range (inches water)
Up to 12 at 10 L
Built-in Timer/Clock
Clock
Constant Flow
Yes
Programmable
Yes
PC-compatible
Yes
Multi-tube Sampling
N/A
Flow Fault Feature
Yes
RFI/EMI Shielded
Yes
MSHA-approved Models Available
N/A
ATEX Models Available
N/A
CE Marked
Yes
Corrects for Changes in
Atmospheric Pressure
Yes
Corrects for Changes in
Temperature
Yes
Battery Type
Li-Ion (7.4 V, 12 Ah, 88.8 Wh)
Battery Check
Yes
Tubing
Requires 3/8-inch ID tubing

Recommended Accessories
Chargers
Battery Charging Adapter
Cat. No. 223-248
CalChek Communication Cable
Cat. No. 210-502
Noise-reducing Case
TSI 4146 Calibration Kit
Cat. No. 740-4146
DataTrac Software for Leland Legacy
Cat. No. 877-92
Low-volume PUF Tube Holder
Cat. No. 224-29P
Filter Holders
Tubing

SKC South 434-352-7149



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Author                          : SKC Inc.
Create Date                     : 2017:03:01 10:16:02-05:00
Keywords                        : Leland, Legacy, Sample, Pump, Cat., No., 100-3002, Spec, Sheet, Publication, 1620, PDF, Document
Modify Date                     : 2017:03:01 10:29:59-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:03:01 10:29:59-05:00
Producer                        : Acrobat Distiller 10.1.16 (Windows)
Format                          : application/pdf
Title                           : Leland Legacy Sample Pump Cat. No. 100-3002 Spec Sheet Publication 1620 PDF Document
Creator                         : SKC Inc.
Description                     : Leland Legacy Sample Pump Cat. No. 100-3002 Spec Sheet Publication 1620 PDF Document
Subject                         : Leland Legacy Sample Pump Cat. No. 100-3002 Spec Sheet Publication 1620 PDF Document
Document ID                     : uuid:58c6e284-77a0-479e-a00d-0c7090ae9aac
Instance ID                     : uuid:4a86fc50-0013-49d6-af32-059688297aa5
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu