Leland Legacy Sample Pump Cat. No. 100 3002 Spec Sheet Publication 1620 PDF
User Manual: 1620
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Publication 1620 Rev 1702 Leland Legacy Sample Pump High Flows, Long Runs Enhance Measurement Sensitivity! Flows: 5 to 15 L/min Certifications Charging port performance verified Secure belt clip Data port Protective inlet filter Protective cover Bright status LED Top view 8 inches Leland Legacy® is the perfect partner for the Sioutas Impactor 3.9 inches High flows — 5 to 15 L/min • Provides the high flows and long run times of a vacuum-style pump in a compact, portable, battery-operated sampler within specified back pressure range CalChek automatic calibration feature • Provides hands-free direct communication to a Defender calibrator Adjustable datalogging interval from 3 seconds to 8 hours with DataTrac Software Designed for use with impactors, spore traps, 37-mm filters, low-volume PUF tubes, and other low-pressure applications† Rugged and convenient case design Long 24-hour runs on one charge with Li-Ion battery • Tough rubber overmolding protects the pump and provides a sure grip • Anti-static thermoplastic material • Inlet port with removable protective cover • Easy-access computer interface and battery charging jack under protective cover • Suitable for unattended ambient air sampling Low noise, size, and weight • Ideal for indoor air studies or unattended ambient air sampling Longer runs + Higher flows = Enhanced sensitivity for measuring low concentrations Performance with Sioutas Impactor verified by EPA-ETV Patented* highly accurate isothermal flow control system Featured in deployable sampler systems Flexible programming options CE marked • Manual three-button programmability using the large built-in keypad • PC programmability with DataTrac Software for Leland Legacy – Create complete running sequences, download sampling history, and generate exposure reports for ISO 9000 or quality programs * U.S. Patent No. 5,892,160 † Leland Legacy is not recommended for high back pressure applications such as asbestos clearance sampling. Large easy-to-read LCD • Displays battery status indicator, flow fault, run time data, and sampling parameters SKC Inc. 724-941-9701 SKC-West 714-992-2780 SKC Gulf Coast 281-859-8050 www.skcinc.com SKC South 434-352-7149 Quick View Leland Legacy Sample Pump Performance Profile Flow Rate Accuracy Timing Accuracy Atmospheric Pressure Accuracy Typical Run Time Charge Time (varies with battery capacity and level of discharge) Temperature Range Altitude Timer Display Range Time Display Volume Display Noise Level Flow Fault Flow Control Weight ± 5% of set-point after calibration 1 min/mo at 25 C ± 3% in Hg Battery: 24 hrs at 9 L/min with Sioutas Impactor (approx. 13 in water back pressure) 24 hrs at 5 L/min with low-volume PUF tube 24 hrs at 10 L/min with IMPACT Sampler in DPS System 24 hrs at 8 L/min with 8 L/min Respirable PPI Using charger with AC power: Extended run times 15 hrs with approved charger Operating: 32 to 104 F (0 to 40 C) Storage: -4 to 95 F (-20 to 35 C) Charging: 32 to 113 F (0 to 45 C) The pump can apply correction to volumetric flow during sampling for weather-related or altitude variations from the atmospheric pressure established at calibration up to at least 7500 feet above and 5000 feet below sea level. 1 to 99999 min (69 days); if run time exceeds 69 days, timer display rolls over Time of day in hours and minutes (12 or 24-hr clock) with AM and PM indicators Continually updated based on corrected flow rate multiplied by sampling time When volume exceeds 99,999 liters, the pump will continue to run normally but an O_FLO Error will appear on the LCD. 62.5 dBA‡ - pump without case 52 dBA‡ - pump housed in noise-reducing case (optional accessory) After 15 sec, pump goes into Hold, retains accumulated run time and historical data, and displays fault icon. Auto-restart is attempted every 20 sec up to 10 times (adjustable with DataTrac Software) An internal isothermal flow sensor measures flow directly and continuously. Sensor readings are used in a flow monitoring algorithm to maintain calibrated volumetric flow. In addition, builtin atmospheric temperature and pressure sensors provide readings to correct volumetric flow for these parameters when they vary from point of calibration. 36 oz (1 kg) ‡ Measured 3 feet (1 meter) from pump operating at 10 L/min and 12 inches water back pressure Ordering Information Leland Legacy requires 3/8-inch ID tubing. Pump and Kits Leland Legacy Pump** with Li-Ion battery pack and screwdriver set, requires charger Starter Kit includes pump, single charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie Single Pump Kit**# includes Leland Legacy pump and single charger, in a Pelican carry case 5-pack Pump Kit**# includes 5 Leland Legacy pumps, Take Charge 5 Multi-charger, and DataTrac Software, in a deluxe Pelican case Accessories TSI 4146 Calibration Kit, flow measurement from 0.01 to 20 L/min, includes calibrator, soft-side case, mounting lugs, 1/4-inch ID tubing, battery pack, 6 AA batteries, inlet filter, dampening module, NIST certificate, and manual Chargers Single Take Charge 5 Multi-charger CalChek Communication Cable, required for CalChek calibration Replacement Parts Replacement Battery Pack,** Li-Ion Replacing batteries with non-approved battery packs voids any warranty. Replacement Filter/O-ring Set, 5 filters and 1 O-ring Replacement Inlet Filters, pk/50 Cat. No. 100-3002 100-240 V 100-240 V 100-3002-S 100-3002K 100-240 V 100-3002K5 740-4146 100-240 V 100-240 V 223-241 223-441 210-502 P75692 P40021B P40021A ** Leland Legacy pumps contain Li-Ion batteries and may be subject to special shipping regulations. SKC Limited Warranty and Return Policy SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC’s sole liability and the buyer’s exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to http://www.skcinc.com/warranty.asp. SKC Inc. 724-941-9701 SKC-West 714-992-2780 SKC Gulf Coast 281-859-8050 www.skcinc.com Flow Rate (ml/min) 5 to 15 (L/min) Weight in Ounces (grams) 36 (1000) Compensation Range (inches water) Up to 12 at 10 L Built-in Timer/Clock Clock Constant Flow Yes Programmable Yes PC-compatible Yes Multi-tube Sampling N/A Flow Fault Feature Yes RFI/EMI Shielded Yes MSHA-approved Models Available N/A ATEX Models Available N/A CE Marked Yes Corrects for Changes in Atmospheric Pressure Yes Corrects for Changes in Temperature Yes Battery Type Li-Ion (7.4 V, 12 Ah, 88.8 Wh) Battery Check Yes Tubing Requires 3/8-inch ID tubing Recommended Accessories Chargers Battery Charging Adapter Cat. No. 223-248 CalChek Communication Cable Cat. No. 210-502 Noise-reducing Case TSI 4146 Calibration Kit Cat. No. 740-4146 DataTrac Software for Leland Legacy Cat. No. 877-92 Low-volume PUF Tube Holder Cat. No. 224-29P Filter Holders Tubing SKC South 434-352-7149
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Print high-res Author : SKC Inc. Create Date : 2017:03:01 10:16:02-05:00 Keywords : Leland, Legacy, Sample, Pump, Cat., No., 100-3002, Spec, Sheet, Publication, 1620, PDF, Document Modify Date : 2017:03:01 10:29:59-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:03:01 10:29:59-05:00 Producer : Acrobat Distiller 10.1.16 (Windows) Format : application/pdf Title : Leland Legacy Sample Pump Cat. No. 100-3002 Spec Sheet Publication 1620 PDF Document Creator : SKC Inc. Description : Leland Legacy Sample Pump Cat. No. 100-3002 Spec Sheet Publication 1620 PDF Document Subject : Leland Legacy Sample Pump Cat. No. 100-3002 Spec Sheet Publication 1620 PDF Document Document ID : uuid:58c6e284-77a0-479e-a00d-0c7090ae9aac Instance ID : uuid:4a86fc50-0013-49d6-af32-059688297aa5 Page Count : 2EXIF Metadata provided by EXIF.tools