800 4247 02_Field_Engineer_Handbook_Vol_2_Dec90 02 Field Engineer Handbook Vol 2 Dec90

800-4247-02_Field_Engineer_Handbook_Vol_2_Dec90 800-4247-02_Field_Engineer_Handbook_Vol_2_Dec90

User Manual: 800-4247-02_Field_Engineer_Handbook_Vol_2_Dec90

Open the PDF directly: View PDF PDF.
Page Count: 338

Download800-4247-02_Field_Engineer_Handbook_Vol_2_Dec90 800-4247-02 Field Engineer Handbook Vol 2 Dec90
Open PDF In BrowserView PDF
Field Engineer Handbook
Technical Volume II

Sun Microsystems, Inc.
Customer Service Division
2550 Garcia Avenue
Mountain View, CA 94043

ParI No: 800·4241-02
© 1990 Sun Microsystems, Inc.

Written and published by Mike Persichetty and Gerri Roe.

The Sun logo, Sun Microsystems, Sun Workstation, are registered
trademarks of Sun Microsystems.
Sun, Sun-2, Sun-3, Sun-4, Sun386i, SPARCstation, SPARCserver,
SunView, SunLink, SunIPC, PC-NFS, NFS, SunOS, NeWS, SunGKS,
Sun CGI, SunSimplify, SunPro, NSE, TAAC-1, SunTrac, ONC, DOS
Windows. SPE. and ALM are registered trademarks of Sun Microsystems, Inc.
UNIX is a registered trademark of AT&T: OPEN LOOK is a trademark of AT&T.
All other products or services mentioned in this document are
identified by trademarks or service marks of their respective companies or organizations.

Copyright

@

1990 by Sun Microsystems, Inc.

This publication is protected by Federal Copyright Law, with all rights
reserved. No part of this publication may be reproduced, stored in a
retrieval system, translated, transcribed, or transmitted, in any form,
or by any means, manual, electric, electronic, electro-magnetic,
mechanical, chemical, optical, or otherwise without prior explicit
written permission from Sun Microsystems, Incorporated.
Printed in USA

12/90

Preface
The Field Engineer (FE) Handbook - Technical Volumes I
and II, describes and illustrates specific Sun Microsystems,
Inc. products. While Sun publishes extensive hardware
documents, this handbook is a portable reference manual
for Field Engineers, support personnel, and customers. Sun
Field Engineers and customers equipped with the FE
Handbook may perform service calls accurately an efficiently,
thus reflecting Sun's commitment to quality customer service.
This handbook complements other Sun technical publications
and education courses. We assume that Sun Field
Engineers, support personnel, and customers who service
and repair Sun products have access to these resources.

Field Engineer Handbook - Technical Volume II

OVERVIEW

12/90

Handbook Organization
The technical information contained in the Field Engineer
Handbook is organized into two volumes.
Volume I contains the following sections.
•

Configurations. Contains illustrations identifying jumper
and switch locations, and configuration tables for field
replaceable boards.

•

Power Supplies. Contains illustrations of power supplies
and power distribution units with power supply
specifications.

Volume II contains the following sections.
•

Parts Breakdowns. This section contains part numbers
and descriptions for Sun systems, racks, options,
boards, monitors, keyboard/mouse, and provides miscellaneous hardware information.

•

Troubleshooting. This section contains error code charts
for CPUs, disks, tapes, and communications.

•

Operating Systems. Contains selected software charts.

•

Diagnostics. Describes diagnostics .tools.

OVIEW-2

Field Engineer Handbook

I

12/90

OVERVIEW

Revision History
DESCRIPTION

DATE

6/87
11/87
4/88
9/88
5/89
10/89

First Edition
Second Edition
Third Edition
Fourth Edition
Fifth Edition
Supplement

5/90

Supplement

12/90

Sixth Edition

Technical Volume II

PART NO.

800-1819-01
800-1819-01
800-4006-01
800-4006-02
800-4006-03
800-4704-01

Entire contents
Entire contents
Entire contents
Entire contents
Change pages
New Products
Change pages 800-5140-01
New Products
Entire contents
Vol-I
800-4006-04
Vol-II
800-4247-02

OVIEW-3

PARTS BREAKDOWN

12/90

Parts Breakdown
This section contains System, Rack, Option, Board, Monitor,
Keyboard/Mouse, and Miscellaneous part numbers and
descriptions. This section is intended for use by Sun Field Engineers. Use this section with the Field Service Manual for a
specific product for further detail.
Parts listed as (obsolete) or (obs) are no longer used by Sun
Manufacturing to build systems. Obsolete parts may be
replaced with newer part numbers and may not be available.
Sun spare parts available for sale are listed in the SunSpares
Price List. Sun manuals available for sale are listed in the Sun
Manuals Price List.
Standard Configurations and Standard Options supported by
Sun Microsystems are documented in Configuration Guides,
Technical Reports, Product Brochures, Price Lists, and Hardware Installation Manuals.
Abbreviations

FRU Field Replaceable Unit
CRU Customer Replaceable Unit
DRU Depot Replaceable Unit
MSS Mass Storage Subsystem
MSP Mass Storage Pedestal
ESM External Storage Module
EEM External Expansion Module
Obs Obsolete Part
Assy Assembly
NS
Indicates the part is not illustrated
•
Indicates the part is used in an assembly
w
With
w/o
Without

Field Engineer Handbook - Technical Volume II

PARTS BREAKDOWN

12/90

Class Codes
The first three digits of a Sun part number are the class code.
Representative class codes are listed below.
CLASS CODE

270-xxxx-xx
300-xxxx-xx
330-xxxx-xx
340-xxxx-xx
365-xxxx-xx
370-xxxx-xx
500-xxxx-xx
501-xxxx-xx
520-xxxx-xx
525-xxxx-xx
530-xxxx-xx
540-xxxx-xx
555-xxxx-xx
560-xxxx-xx
570-xxxx-xx
595-xxxx-xx
596-xxxx-xx
600-xxxx-xx
700-xxxx-xx
704-xxxx-xx
790-xxxx-xx
800-xxxx-xx
813-xxxx-xx

PTS/BK-2

DESCRIPTION

PCB Fabrication
Power Supply
Plastic part
Sheet metal part
Monitor Assembly
OEM part
Untested PCB
Tested PCB
Programmed IC
Programmed IC
Cable
Assembly
FRU Assembly
Shipping Kit
Electro Mechanical Assy
Top Level Option Assy
Configured Option Assy
Top Level System Assy
Software Tape
Software CD-ROM
Software Tape & Manual
Sun Manual
Configuration Manual

Field Engineer Handbook

PARTS BREAKDOWN

SYSTEM

PARTS BREAKDOWN

12/90

System
MULTIBUS
Sun-2/100U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-2/150U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-2/120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-2/170 .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..

3
4
6
9

VME
Sun-2/50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-2/130/160 ............................
Sun-3/50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-3/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-3/75 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-3/110/140 ............................
Sun-3/150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-3/160/260/460 & Sun-4/260/360 ..........
Sun-3/180/280/480 & Sun-4/280/380 ..........
Sun-3/470 & Sun-4/370/470 .................
Sun-4/11 0/31 0 ............................
Sun-4/150/350 ............................
Sun-4/330 ... . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-4/370/470 ............................
Sun-4/390/490 ............................

12
13
16
17
18
19
20
21
25
33
34
35
36
40
44

Sun386i
Sun386i1150/250 ...........................

49

DESKTOP
Sun-3/80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-4/20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-4/40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-4/60/65 ..............................

52
54
56
58

Sun-4/75 .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..

60

Reid Engineer Handbook - Technical Volume II

12/90

PARTS BREAKDOWN

This page intentionally left blank.

SYS-2

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-2/100U
7-Slot Multibus Logic Enclosure
PART #

DESCRIPTION

140-1002
Fuse, 3.15A (240V)
140-1030
Fuse, 6.3A (115V)
AC Filter/Fuse/Switch
150-0137
150 Watt Power Supply, Powertech (obsolete)
300-0135
300-0135-03 200 Watt Power Supply, Power-One
340-0332
Backplane & Cardcage Assembly, without DC Harness
340-1052
Mounting Bracket, Power-One Power Supply
370-0138
AC Fan, 25 CFM, 115V (obsolete)
AC Fan, 25 CFM, 240V
370-0157
370-1013
AC Fan, 35 CFM, 115V
Internal SMD Disk Data Cable
530-0129
530-0132
Internal SMD Disk Command Cable
530-0139
AC Harness, AC Filter to Power Supply
530-0169
Internal RS-232 Cable
DC Harness, Power Supply to Backplane DC Harness
530-0178
530-0179
DC Harness, Backplane (solders to the backplane)
530-0204
AC Harness, AC Filter to 530-0421
530-0239
Internal Keyboard/Mouse Cable
530-0286
Internal Ethernet Cable
530-0421
AC Harness, 530-0204 to 17" Monitor
530-0491-02 Internal Tape Command Cable, Tape A
530-0491-03 Internal Tape Command Cable, Tape B
530-0495
Internal Color Cable, BNC
530-1048
AC Ground Strap, AC Filter to Backplane
530-1044
Internal Monochrome Video Cable

Technical Volume II

SYS-3

12/90

PARTS BREAKDOWN

Sun-2I150U
15-Slot Multibus Logic Enclosure
PART #

150-0648
150-1008
150-1009
300-0645
300-0645
340-0613
340-0644
340-1012
370-0172
370-0242
530-0495-02
530-1000
530-1001
530-1031
530-1032
530-1033
530-1034
530-1035
530-1036
530-1037
530-1038
530-1039
530-1059

DESCRIPTION

AC Line Filter
AC Indicator Lamp
AC Circuit Breaker, 15 Amp
1000 Watt Power Supply, Powertec 1
1000 Watt Power Supply, LH 1
Rear Filler Panel, Blank
Cardcage & Backplane Assembly
Mounting Bracket. LH Power Supply
AC Fan, 115V, 75 CFM
AC Fan, 240V, 75 CFM
Internal Color Cable, BNC
AC Harness, AC Filter to Circuit Breaker
AC Harness, Fans
Internal Ethernet Cable
Internal SMD Disk Command Cable
Internal Tape Command Cable
Internal SMD Disk Data Cable
Internal Keyboard/Mouse Cable
Internal RS-232 Cable
Internal Monochrome Video Cable
Door Ground Strap
Ground Strap, Chassis to Power Supply to Backplane
DC Wire Harness

1 These Power Supplies are not interchangeable. The LH Power Supply

requires mounting bracket 340-1012.

SYS-4

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-21100U/150U
Keyboard and Mouse
PART #

DESCRIPTION

540-1014 Keyboard Assembly
320-0292 • Keytronics Keyboard
530-1030 • Keyboard Cable, OB-25
530-1042 Keyboard Extension Cable, 25', OB-25 to OB-25
550-0111 Keyboard Assembly (obsolete)
320-0112 • Microswitch Keyboard
530-0115 • Keyboard Cable, OB-25
550-0306
530-1040

Parallel Mouse & Pad, OB-15
Mouse Extension Cable, 25', OB-15 to OB-15

Monitors
DESCRIPTION

PART #

540-1015 17" Sun-2/100U Monochrome Monitor Assembly
360-0484 • 17" Monochrome Monitor
530-0421 • Internal AC Power Cable
530-1044 • Internal Video Cable
540-1016
360-0484
530-1002
530-1003
530-1041

17" Sun-2/150U Monochrome Monitor Assembly
• 17" Monochrome Monitor
• Internal Video Cable
• Internal AC Wire Harness
External Video Cable, 15'

360-0595 13" Barco Color Monitor
180-1097
AC Power Cord
530-0492 • External Color Video Cable, 1x BNC to BNC

•

360-1002 19" Color Monitor
180-1097
AC Power Cord
530-0492 • External Color Video Cable, 1x BNC to BNC

•

Technical Volume II

SYS-5

PARTS BREAKDOWN

12/90

Sun-2/120
9-810t Multibus Logic Enclosure
PART #

140-1002
140-1010
150-1041
150-1042
150-1018
150-1039
180-1027
180-1097
240-1020
240-1048
300-1000
300-1004
330-1009
340-1039
340-1040
340-1049
340-1069
340-1037
340-1037
340-1261
340-1262
501-1049
501-1090
540-1018
540-1128
540-1509
530-1060
530-1101
530-1105
530-1027
530-1051
530-1100
530-1014
530-1015

SYS-6

DESCRIPTION

Fuse, 3.15A (240V)
Fuse. 5A (115V)
Fuseholder
Fusecarrier
Power Switch, Illuminated
AC Line Filter
AC Power Cord (115V) (obsolete)
AC Power Cord (115V)
Air Filter
Swivel Caster
750 Watt Power Supply, LH Research (early units only)
750 Watt Power Supply, Boschert
Front Bezel
Top Cover
Cardcage EMI Cover
Blank Rear Filler Panel
Shipping Bracket
Side Cover. Right (340-1037-01) (obsolete)
Side Cover, Left (340-1037-02) (obsolete)
Side Cover, Right
Side Cover. Left
9-Slot Multibus Prime Backplane
9-Slot Multibus Backplane (obsolete)
Cardcage & Backplane Assembly
DC Fan Assembly, 71 CFM
DC Fan Assembly, 88 CFM (obsolete)
Ground Cable, LH Research Power Supply
DC Harness, LH Research Power Supply to Backplane
DC Harness. Boschert Power Supply to Backplane
DC Harness. Power Supply to SCSI Peripherals to Backplane
AC Receptacle & AC Harness. Receptacle to Fuse to Filter
DC Harness, Power Supply to Fan
AC Harness, Line Filter to Power Switch
AC Harness, Power Switch to Power Supply

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-2/120
Output Cable Panel Assemblies
PART #

540-1011
540-1022
540-1023
530-1072
530-1160
540-1010
530-1071
530-1128
540-1020
501-1015
501-1082
530-1057
530-1061
540-1021
530-0495
540-1025
530-1097
540-1026
530-1064
540-1059
530-1099
530-1161
540-1280
530-1168
540-1296
530-1228
530-1229

DESCRIPTION

RS-232 Cable Panel Assembly, CPU Port A & B
RS-232 Cable Panel Assembly. SCSI Port C & D
RS-232 Cable Panel Assembly, SCSI Port E & F
• RS-232 Cable (obsolete)
• RS-232 Cable
Ethernet Cable Panel Assembly
• Ethernet Cable (obsolete)
• Ethernet Cable
Keyboard. Mouse, Monochrome Video Cable Panel Assy
• Keyboard & Mouse Interface PCB (obsolete)
• Keyboard & Mouse Interface PCB
• Monochrome Video Cable
• Keyboard & Mouse Cable
Color Video Cable Panel Assembly
• Color Video Cable
SMD Command Cable Panel Assembly
• SMD Command Cable
SMD Data Cable Panel Assembly
• SMD Data Cable
1/2" Tape Cable Panel Assembly
• 1/2" Tape Command Cable (obsolete)
• 1/2" Tape Command Cable
RS-232 Cable Panel Assembly, Port 1 - 8
• RS-232 Cable, Systech MTI 800/850
RS-232 & RS-449 Cable Panel Assembly
• RS-232 Cable, Systech DCP 8804
• RS-449 Cable, Systech DCP 8804

Technical Volume II

SYS-7

12/90

PARTS BREAKDOWN

Sun-2/120
Tape & Disk Drive Options
PART #

DESCRIPTION

330-1035
370-1010
370-1015
370-1034
370-1034
530-1162
530-1026
530-1054

Cable Shield, Adaptec ACB-4000
Adaptec ACB-4000 SCSI Disk Controller
42MB Disk Drive, Micropolis 1304
71 MB Disk Drive, Micropolis 1325
71 MB Disk Drive, Fujitsu M2243AS
SCSI Disk Command Cable
SCSI Disc Data Cable
SCSI Command Cable, Host Adapter to Adaptec to Sysgen

330-1034
370-1011
370-0544
370-0544
530-1024
530-1054

Cable Shield, Sysgen SC4000
Sysgen SC4000 SCSI Tape Controller
20MB 1/4" Tape Drive, QIC-11, Archive 9020
20MB 1/4" Tape Drive, QIC-11, Cipher F420-90
Tape Command Cable, Sysgen SC4000 to Tape Drive
SCSI Command Cable, Host Adapter to Adaptec to Sysgen

330-1034
370-1011
370-1024
370-1026
530-1024
530-1054
530-1115

Cable Shield, Sysgen SC4000
Sysgen SC4000 SCSI Tape Controller
20MB 1/4" Tape Drive, QIC-11, Archive Basic 9020
Archive Stand Alone Controller (SAC)
Tape Command Cable, Sysgen SC4000 to Tape Drive
SCSI Command Cable, Host Adapter to Adaptec to Sysgen
Tape Command Cable, SAC to Archive Basic 9020

SYS-8

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-2/170
15-Slot Multibus Logic Enclosure
PART #

140-1002
140-1010
150-1041
150-1042
150-1018
150-1039
180-1027
180-1097
300-1004
340-1049
340-1261
340-1262
530-1075
530-1078
530-1154
540-1017
501-1050
501-1150
540-1509

DESCRIPTION

Fuse, 3.15A (240V)
Fuse, 5A (115V)
Fuseholder
Fusecarrier
Power Switch, Illuminated
AC Line Filter
AC Power Cord (115V) (obsolete)
AC Power Cord (115V)
750 Watt Power Supply, Boschert
Blank Rear Filler Panel
Side Cover, Right
Side Cover, Left
AC Harness, Line Filter to Switch to Power Supply
AC Receptacle & AC Harness, Receptacle to Fuse to Filter
DC Harness, DC Fans
Cardcage & Backplane Assembly
• 15-Slot Multibus Prime Backplane
• 15-Slot Multibus Backplane (obsolete)
DC Fan Assembly, 88 CFM

Technical Volume II

SYS-9

12/90

PARTS BREAKDOWN

Sun-2I170
Output Cable Panel Assemblies
PART #

540-1048
530-1099
530-1215
530-1107
540-1031
530-1128
540-1027
501-1015
501-1082
530-1057
530-1058
530-1061
540-1035
530-0495
540-1045
540-1050
530-1097
530-1064
530-1218
540-1043
530-1099
530-1215
540-1278
540-1279
530-1169
530-1175
540-1296
530-1176
530-1182

SYS-10

DESCRIPTION

SCSI Cable Panel Assembly, SCSI Bus & ttysO-3
• SCSI Bus Cable (obsolete)
• SCSI Bus Cable
• RS-232 Cable
Ethernet Cable Panel Assembly
• Ethernet Cable
Keyboard, Mouse, Monochrome Video Cable Panel Assy
• Keyboard & Mouse Interface PCB (obsolete)
• Keyboard & Mouse Interface PCB
• Monochrome Video Cable
• Monochrome Video Cable (obsolete)
• Keyboard & Mouse Cable
Color Video Cable Panel Assembly
• Color Video Cable
SMD Command & Data Cable Panel Assembly
SMD Command & Data Cable Panel Assembly
• SMD Command Cable
• SMD Data Cable (obsolete)
• SMD Data Cable
1/2" Tape Cable Panel Assembly
• 1/2" Tape Command Cable (obsolete)
• 1/2" Tape Command Cable
RS-232 Cable Panel Assembly, Port 8-13
RS-232 Cable Panel Assembly, Port 1-8
• RS-232 Cable, MTI 800/850/1600/1650, Port 1-8
• RS-232 Cable, MTI 800/850/1600/1650, Port 8-13
RS-232 & RS-449 Cable Panel Assembly
• RS-232 Cable, Systech DCP 8804
• RS-449 Cable, Systech DCP 8804

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-2/120/170
Keyboard and Mouse
PART #

DESCRIPTION

540-1006 Microswitch Keyboard Assembly
320-1000 • Microswitch Keyboard PCB
530-1069 • Keyboard Cable, RJ11
130-1078 Coupler, RJ11 to RJ11
370-1090 • M2/M31 Mouse & Pad, RJ11
550-1000 • M2/M31 Mouse & Pad, RJ11 (obsolete)
530-1062 • Mouse Extension Cable, RJ11 to RJ11

Monitors
PART #

DESCRIPTION

360-0595 13" Barco Color Monitor, 475x640, 60Hz
180-1097 AC Power Cord
530-0492 External Color Video Cable, 1x BNC to BNC
360-1002
180-1097
530-0492
530-1138
530-1307
530-1362

19" Color Monitor, 475x640, 60Hz
AC Power Cord
Color Video Cable, 1x BNC to BNC (obsolete)
Color Video Cable, 4x BNC to BNC, 5.0M (obsolete)
Color Video Cable, 4x BNC to BNC, 5.0M
Color Video Cable, 4x BNC to BNC, 1.2M

365-1037
540-1005
540-1029
180-1097
530-1125

19" Monochrome Monitor, TTL, 1152x900, 66Hz
19" Monochrome Monitor, TIL, 1152x900, 66Hz (obsolete)
19" Monochrome Monitor, OCL!, TTL, 1152x900, 66Hz
AC Power Cord (115V)
Monochrome Video Cable, 15'

Technical Volume II

SYS-11

PARTS BREAKDOWN

12/90

Sun-2/50
2-810t VMEbus Logic Enclosure
PART #

140-1031
150-1258
180-1010
180-1027
180-1097
180-1117
180-1125
230-1025
230-1033
240-1024
300-1002
330-1013
340-1178
501-1042
530-1020
540-1068
540-1069
540-1100
540-1102
540-1104
540-1105
540-1393
800-1222

SYS-12

DESCRIPTION

Fuse, 4A (240V)
Fuse, 7A (115V)
AC Power Cord, Coiled, AC Output Receptacle to Monitor
AC Power Cord (115V) (obsolete)
AC Power Cord (115V)
AC Power Cord, AC Output Receptacle to Monitor
AC Power Cord (240V)
Rubber Foot
Chassis Cover Screw O-Ring
Chassis Cover Screw
Power Supply
Teflon Ring
Fan Fingerguard
2-Slot Backplane (Rivetted to the Chassis)
AC Input Receptacle with AC Wire Harness
DC Fan Assembly, 25 CFM (Rivetted to the Chassis)
AC Output Receptacle
Top Cover
2-Slot Chassis without Cover
2-Slot Chassis with Cover
Internal RFI Shield
110/220 Voltage Select Switch Assembly
Sun-2/50 Field Service Manual

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-2/130/160
12-810t VMEbus Logic Enclosure
PART #

140-1017
150-1018
150-1041
150-1042
150-1051
150-1322
180-1027
180-1097
180-1125
240-1048
300-1004
340-1138
340-1037
340-1037
340-1261
340-1262
370-1086
501-1053
530-1187
501-1085
530-1119
530-1121
530-1123
530-1134
530-1159
530-1170
530-1171
530-1163
540-1300
540-1252

DESCRIPTION

Fuse, 10A (115V)
AC Power Switch
Fuse Holder (115V)
Fusecarrier (115V)
Fuse Carrier (240V)
AC Line Filter
AC Power Cord (115V) (obsolete)
AC Power Cord (115V)
AC Power Cord (240V)
Caster
750 Watt Power Supply
Top Cover
Side Cover, Right (340-1037-01) (obsolete)
Side Cover, Left (340-1037-02) (obsolete)
Side Cover, Right
Side Cover, Left
12-Slot Cardcage
12-Slot VMEbus Backplane 1
• Molex Connector Harness (soldered to the Backplane)
12-Slot VMEbus Backplane (Pressfit) 1
DC Harness, Power Supply to Backplane to Peripheral Tray
AC Switch Harness
AC Harness, AC Receptacle to AC Filter
SCSI Bus Cable, Backplane to SCSI Tray
Power Supply Ground Harness
DC Harness, Upper DC Fan
DC Harness, Upper DC Fan
DC Harness, Fan Tray
Power Supply RC Filter (required by Graphics Processor)
DC Fan Assembly, 71 CFM

1 Slots 5-12, P3 Row B, Pins 33-64, are connected together on Backplane

FAB 270-1 053-03 and 270-1 085-01 .

Technical Volume II

SYS-13

12/90

PARTS BREAKDOWN

Sun-2/130/160
Tape & Disk Drive Options
PART #

DESCRIPTION

370-1010
370-1034
370-1034
530-1134
530-1135
530-1142
530-1145
530-1157

Adaptec ACB-4000 Disk Controller
71 MB Disk Drive, Micropolis 1325
71 MB Disk Drive, Fujitsu M2243AS
SCSI Bus Cable, Backplane to SCSI Tray
DC Harness, SCSI Tray to Power Supply Harness
SCSI Data Cable, 4", LUN 0
SCSI Data Cable, 9", LUN 1
SCSI Command Cable, Dual Disk

370-1011
370-1037
370-1112
370-1112
530-1141

Sysgen SC4000 Tape Controller
45/60MB 114" Tape Drive, QIC-11/24, Wangtech 5099EG11
45/60MB 114" Tape Drive, QIC-11/24, Wangtech 5099EG11
45/60MB 114" Tape Drive, QIC-11/24, Archive 5945L-2
Tape Command Cable, Sysgen SC4000 to Tape Drive

SYS-14

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-2150/130/160
Keyboard and Mouse
PART #

DESCRIPTION

540-1006
320-1000
530-1068
530-1069

Sun-2 Keyboard Assembly, RJ11
• Microswitch Keyboard
• External Keyboard Cable, 3.65M, RJ11 to RJ11
• External Keyboard Cable, 7.3M, RJ11 to RJ11

540-1107
501-1082

Keyboard/Mouse Adapter Assembly (Mouse House)
• Keyboard/Mouse Adapter PCB

130-1078 RJ11 Coupler, RJ11 to RJ11
370-1090 M2/M3 Mouse & Pad, RJ11
530-1062 Mouse Extension Cable
550-1000

M2/M3 Mouse & Pad, RJ11 (obsolete)

Technical Volume II

SYS-15

12/90

PARTS BREAKDOWN

Sun-3/50
1-Slot Logic Enclosure
PART #

140-1020
150-1258
180-1010
180-1027
180-1097
180-1117
180-1125
300-1015
330-1054
340-1178
340-1365
501-1109
530-1020
540-1069
540-1310
540-1325
540-1326
540-1328
540-1393
540-1078
540-1582
555-1062
230-0203
230-1006
300-1040
800-3235
540-1325
540-1326
800-1356

SYS-16

DESCRIPTION

Fuse, 4A (240V)
Fuse, 7A (115V)
AC Power Cord, Coiled, AC Output Receptacle to Monitor
AC Power Cord (115V) (obsolete)
AC Power Cord (115V)
AC Power Cord, AC Output Receptacle to Monitor
AC Power Cord (240V)
100 Watt Power Supply (obsolete)
Backplane Insulator Shield (Rivetted to the Chassis)
Fan Fingerguard
Power Supply EMI Cover
1-Slot Backplane (Rivetted to the Chassis)
AC Receptacle & AC Switch & Fuse Assembly
AC Output Receptacle
Top Cover Assembly with Monitor Mounting Hardware
1-Slot Chassis with Cover
1-Slot Chassis without Cover
DC Fan Assembly, 25 CFM (Rivetted to the Chassis)
110/220 Voltage Select Switch
110/220 Voltage Select Switch (obsolete)
110/220 Voltage Select Switch
116 Watt Power Supply Kit
• Tiewrap, 2"
• Hole Plug, 1/2"
• 116 Watt Power Supply
• Read This First, 116 Watt Power Supply
1-Slot Chassis, Dimple-Top with Top Cover
1-Slot Chassis, Dimple-Top without Top Cover
Field Service Manual for the Sun-3/50M Desktop
Workstation

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/50/60
1-Slot Logic Enclosure
PART #

140-1020
150-1258
180-1010
180-1097
180-1117
180-1125
300-1015
330-1109
330-1110
340-1575
501-1277
530-1020
540-1069
540-1078
540-1557
540-1582
555-1062
230-0203
230-1006
300-1040
800-3235
599-1402
800-3426

DESCRIPTION

Fuse, 4A (240V)
Fuse, 7A (115V)
AC Power Cord, Coiled, AC Output Receptacle to Monitor
AC Power Cord (115V)
AC Power Cord, AC Output Receptacle to Monitor
AC Power Cord (240V)
100 Watt Power Supply (obsolete)
Top Cover
Backplane Insulator Shield (Rivetted to the Chassis)
Power Supply EMI Cover
1-Slot Backplane (Rivetted to the Chassis)
AC Receptacle & AC Switch & Fuse Assembly
AC Output Receptacle & Harness, Receptacle to Power Supply
AC Voltage Select Switch, 110/220V (obsolete)
DC Fan Assembly, 49 CFM
110/220 Voltage Select Switch
116 Watt Power Supply Kit
• Tiewrap, 2"
• Hole Plug, 1/2"
• 116 Watt Power Supply
• Read This First, 116 Watt Power Supply
1-Slot Chassis, Flat-Top
Field Service Manual for the Sun-3/50 & Sun-3/60

Technical Volume II

SYS-17

12/90

PARTS BREAKDOWN

Sun-3/75
2-Slot VMEbus Logic Enclosure
PART #

140-1020
180-1010
180-1027
180-1097
180-1117
180-1125
230-1066
300-1017
330-1012
330-1054
340-1365
501-1093
530-1020
540-1069
540-1068
540-1069
540-1078
540-1272
540-1275
540-1310
540-1393

SYS-18

DESCRIPTION

Fuse, 4A (115V/240V)
AC Power Cord, Coiled, AC Output Receptacle to Monitor
AC Power Cord (115V) (obsolete)
AC Power Cord (115V)
AC Power Cord, AC Output Receptacle to Monitor
AC Power Cord (240V)
Rubber Foot
150 Watt Power Supply
Teflon Ring
Backplane Insulator Shield
Power Supply EMI Cover
2-Slot VMEbus Backplane (Rivetted to the Chassis)
AC Receptacle & AC Switch & Fuse Assembly
AC Output Receptacle
DC Fan Assembly, 25 CFM (Rivetted to the Chassis)
AC Output Receptacle
AC Voltage Select Switch, 110/220V (obsolete)
2-Slot Chassis without Cover
2-Slot Chassis with Cover
Top Cover Assembly with Monitor Mounting Hardware
110/220 Voltage Select Switch

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/11 0/140
3-810t VMEbus Logic Enclosure
PART #

140-1019
140-1030
150-1042
150-1051
180-1010
180-1097
180-1117
180-1125
300-1022
300-1022
330-1067
330-1069
330-1071
330-1089
330-1144
340-1545
370-1106
370-1178
501-1127
540-1384
540-1418
540-1419
501-1193
540-1455
540-1535
540-1541
540-1542
800-2126
800-1523

DESCRIPTION

Fuse, 15A (115V)
Fuse, 6.3A (240V)
Fusecarrier (115V)
Fusecarrier (240V)
AC Power Cord, Coiled, AC Output Receptacle to Monitor
AC Power Cord (115V)
AC Power Cord, AC Output Receptacle to Monitor
AC Power Cord (240V)
325 Watt Power Supply, Summit
325 Watt Power Supply, Brown
End Panel. 42 cm X 11 cm
Front Bezel
Side Panel. 42 cm X 59 cm
Side Panel Screw
Backplane Shield
Air Filter Assembly
AC Switch & Fuse (obsolete)
AC Switch & Fuse & Filter Assembly
3-Slot VMEbus Backplane, Pressfit
DC Fan Tray & Power Supply Module Assembly (115V)
Power Supply Module Assembly (115V)
DC Fan Tray Assembly, 4 Fans
• Fan Controller PCB
• DC Fan Assembly, 26 CFM
3-Slot Foot Assembly
Power Supply Module Assembly (240V)
DC Fan Tray & Power Supply Module Assembly (240V)

Field Service Manual for the Sun 3-Slot Logic Enclosure
Sun-3/110 Workstation Field Service Manual

Technical Volume II

SYS-19

PARTS BREAKDOWN

12/90

Sun-3/150
6-Slot VMEbus Logic Enclosure
PART #

140-1019
140-1030
150-1042
150-1051
150-1217
180-1010
180-1097
180-1117
180-1125
330-1068
330-1070
330-1071
330-1089
330-1143
340-1547
370-1106
370-1178
501-1128
530-1352
530-1353
540-1381
540-1409
540-1471
540-1410
300-1020
340--1454
501-1233
540-1475
800-1944

DESCRIPTION

Fuse, 15A (115V)
Fuse, 6.3A (240V)
Fusecarrier (115V)
Fusecarrier (240V)
AC Line Filter (obsolete) 1
AC Power Cord, Coiled, AC Output Receptacle to Monitor
AC Power Cord (115V)
AC Power Cord, AC Output Receptacle to Monitor
AC Power Cord (240V)
End Panel, 42 cm X 17 cm
Front Bezel
Side Panel, 42 cm X 59 cm
Side Panel Screw
Backplane Shield
Air Filter Assembly
AC Switch & Fuse1 (obsolete)
AC Switch & Fuse & Filter Assembly 1
6-Slot VMEbus Backplane, Pressfit
AC Harness, AC Switch to Line Filter (obsolete) 1
AC Harness, Line Filter to Power Supply (obsolete) 1
DC Fan Tray & Power Supply Module Assembly (115V)
DC Fan Tray Assembly, 3 Fans
• DC Fan Assembly, 60 CFM
Power Supply Module Assembly (115V)
• 575 Watt Power Supply
• Power Supply Cover
• Fan Controller PCB
6-Slot Foot Assembly
Field Service Manual for the Sun 6-Slot Logic Enclosure

1 When AC Switch, 370-1106, is replaced with AC Switch, 370-1178,
remove the AC Line Filter, 150-1217, AC Wire Harness, 530-1352,
and AC Wire Harness f30-1353.

SYS-20

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/160/260/460 & Sun-4/260/360
12-810t VMEbus Logic Enclosure
PART #

140-1019
140-1030
150-1018
150-1216
150-1041
150-1042
150-1051
150-1129
180-1097
180-1125
240-1048
330-1066
330-1076
340-1138
340-1261
340-1262
370-1086
501-1092
501-1117
530-1134
530-1135
530-1230
530-1231
530-1207
800-1525
1

DESCRIPTION

Fuse, 15A (115V)
Fuse, 6.3A (240V)
AC Power Switch, Illuminated (obsolete)
AC Power Switch, Non-Illuminated
Fuse Holder (115V)
Fusecarrier (115V)
Fuse Carrier (240V)
AC Line Filter
AC Power Cord (115V)
AC Power Cord (240V)
Castor
Front Bezel
Backplane Cable Shield
Top Cover
Side Panel, Right
Side Panel, Left
12-Slot Cardcage
12-Slot VMEbus Backplane, Pressfit (obsolete)
12-Slot VMEbus Backplane, Pressfit
SCSI Bus Cable, Backplane to SCSI Tray
DC Harness, Power Supply DC Harness to SCSI Tray
AC Receptacle
AC Harness, AC Receptacle to AC Filter
AC Harness, AC Filter to Fuse to Switch to Power Supply
Field Service Manual for the Sun-3/260 Workstation

1

The 300-1016 Power Supply manufactured by Pioneer Magnetics
cannot be installed in systems with AC Wire Harness 530-1207-03
Rev 53 or greater. This wire harness is installed in systems shipped
after February 1987.

Technical Volume II

SYS-21

PARTS BREAKDOWN

12/90

Sun-3/160/260/460 & Sun-4/260/360
Fan Assemblies
PART #

540-1510
530-1171
530-1322

DESCRIPTION

DC Fan Assembly. 71 CFM. Upper Chassis
DC Harness. Power Supply Harness to Upper Fans (obs)
DC Harness. Power Supply Harness to Upper Fans

540-1082 4-Fan Tray Assembly. No Fingerguards (obsolete)
540-1252 • DC Fan Assembly. 71 CFM (obsolete)
540-1510 • DC Fan Assembly. 71 CFM
530-1357 • DC Harness. Fan Tray
540-1555 6-Fan Tray Assembly (obsolete)
540-1510 • DC Fan Assembly. 71 CFM
530-1357 • DC Harness. Fan Tray
540-1581
540-1510
530-1357

6-Fan Tray Assembly. Low Profile. No Fingerguards (obs)
• DC Fan Assembly. 71 CFM
• DC Harness. Fan Tray

540-1584
540-1572
530-1357

6-Fan Tray Assembly. Low Profile. Individual Fingerguards
• DC Fan Assembly. 71 CFM. Low Profile
• DC Harness. Fan Tray

540-1596
540-1572
530-1357

6-Fan Tray Assembly. Low Profile. Full Screen
• DC Fan Assembly. 71 CFM. Low Profile
• DC Harness. Fan Tray

SYS-22

Field Engineer Handbook

PARTS BREAKDOWN

12/90

Sun-3/160
Power Supply
PART #

300-1016
300-1016
300-1016
530-1206
530-1201
530-1324
1

DESCRIPTION

850 Watt Power Supply, Pioneer Magnetics 1
850 Watt Power Supply, ETA
850 Watt Power Supply, Fuji Electrochemical
DC Harness, +5VDC
DC Harness, +5VDC, -5VDC, +12VDC, -12VDC (obsolete)
DC Harness, +5VDC, -5VDC, +12VDC, -12VDC

The 300-1016 Power Supply manufactured by Pioneer Magnetics
cannot be installed in systems with AC Wire Harness 530-1207-03
Rev 53 or greater. This wire harness is installed in systems shipped
after February 1987.

Sun-3/160/260/460 & Sun-4/260/360
Power Supplies
DESCRIPTION

PART #

300-1024 850 Watt Power Supply, Fuji Electrochemical
530-1206 DC Harness, +5VDC
530-1201 DC Harness, +5VDC, -5VDC, +12VDC, -12VDC (obsolete)
530-1324 DC Harness, +5VDC, -5VDC, +12VDC, -12VDC
300-1043
530-1578
530-1581

925 Watt Power Supply, Fuji Electrochemical
DC Harness, +5VDC
DC Harness, +5VDC, -5VDC, +12VDC, -12VDC

Technical Volume II

SYS-23

12/90

PARTS BREAKDOWN

Sun-3/160/260/460 & Sun-4/260/360
Tape & Disk Drive Options
PART #

DESCRIPTION

370-1011 Sysgen SC4000 Tape Controller
370-1037 45/60MB 114" Tape Drive, Wangtech 5099EG11 (obsolete)
370-1112 45/60MB 114" Tape Drive, QIC-11/24, Wangtech 5099EG11
370-1112 45/60MB 114" Tape Drive, QIC-11/24, Archive 5945L-2
530-1141 Tape Command Cable, Sysgen SC4000 to Tape Drive
370-1061
370-1235
370-1076
370-1103
370-1103
530-1141

Emulex MT02 Tape Controller
Emulex MT02 Tape Controller
45/60MB 114" Tape Drive, Wangtech 5099EN24 (obsolete)
45/60MB 114" Tape Drive, QIC-11/24, Wangtech 5099EN24
45/60MB 114" Tape Drive, QIC-11/24, Archive 5945C
Tape Command Cable, Emulex MT02 to Tape Drive

370-1010
370-1034
370-1034
530-1134
530-1135
530-1142
530-1145
530-1157

Adaptec ACB-4000 SCSI Disk Controller
71MB Disk Drive, Micropolis 1325
71 MB Disk Drive, Fujitsu M2243AS
SCSI Bus Cable, Backplane to SCSI Tray
DC Harness, Power Supply DC Harness to SCSI Tray
Disk Data Cable, 39 cm, LUN 0
Disk Data Cable, 62 cm, LUN 1
Disk Command Cable, Dual Disk

370-0552
370-1236
370-0551
370-0551
370-1133
530-1134
530-1135
530-1142
530-1145
530-1157

Emulex MD21 SCSI Disk Controller
Emulex MD21 SCSI Disk Controller
141 MB Disk Drive, Micropolis 1355
141MB Disk Drive, Toshiba MK156
327MB Disk Drive, Micropolis 1558-15
SCSI Bus Cable, Backplane to SCSI Tray
DC Harness, Power Supply DC Harness to SCSI Tray
Disk Data Cable, 39 cm, LUN 0
Disk Data Cable, 62 cm, LUN 1
Disk Command Cable, Dual Disk

SYS-24

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/180/280/480 & Sun-4/280/380
12-Slot VMEbus Logic Enclosure
PART #

140-1019
140-1026
140-1030
150-1018
150-1216
150-1041
150-1042
150-1051
150-1129
180-1097
330-1076
340-1283
340-1583
340-1584
340-1685
340-1686
370-1086
501-1092
501-1117
530-1230

DESCRIPTION

Fuse, 15A (115V)
Fuse, 6A (230V)
Fuse, 6.3A (240V)
AC Power Switch, Illuminated (obsolete)
AC Power Switch, Non-Illuminated
Fuse Holder (115V)
Fusecarrier (115V)
Fuse Carrier (240V)
AC Line Filter
AC Power Cord (115V)
Backplane Cable Shield
Cardcage Mounting Bracket Assembly (obsolete)
• Front & Rear Angle Bracket

530-1257

• Side Angle Bracket
Front EMI Cover
Front EMI Cover
12-Slot Cardcage
12-Slot VMEbus Backplane, Pressfit (obsolete)
12-Slot VMEbus Backplane, Pressfit
AC Receptacle Assembly
AC Harness, AC Receptacle to AC Filter

530-1258
530-1260

Indicator Lamp, 12 VDC (obsolete)

530-1343
530-1351
540-1366
530-1259
530-1321
540-1129
540-1509

AC Harness, AC Filter to Fuse to Switch to Power Supply
AC Power Cord (240V)
AC Power Cord (230V)
Fan Tray Assembly, 4 Fans
• DC Harness, Fan Tray (obsolete)
• DC Harness, Fan Tray
• DC Fan Assembly, 88 CFM (obsolete)

540-1508

• DC Fan Assembly, 88 CFM
Indicator lamp, 12 VDC

540-1585

Cardcage Mounting Bracket Assembly

Technical Volume II

SYS-25

12/90

PARTS BREAKDOWN

Sun-3/180
Power Supply
PART #

DESCRIPTION

300-1016 850 Watt Power Supply, Pioneer Magnetics
300-1016 850 Watt Power Supply, ETA
300-1016 850 Watt Power Supply, Fuji Electrochemical
530-1340 DC Harness, +5VDC
530-1222 DC Harness, +5VDC, -5VDC, +12VDC, -12VDC (obsolete)
530-1320 DC Harness, +5VDC, -5VDC, +12VDC, -12VDC

Sun-3/180/280/480 & Sun-4/280/380
Power Supplies
PART #

DESCRIPTION

300-1024 850 Watt Power Supply, Fuji Electrochemical
530-1206 DC Harness, +5VDC (obsolete)
530-1340 DC Harness, +5VDC
530-1222 DC Harness, +5VDC, -5VDC, +12VDC, -12VDC (obsolete)
530-1320 DC Harness, +5VDC, -5VDC, +12VDC, -12VDC
300-1043 925 Watt Power Supply, Fuji Electrochemical
530-1578 DC Harness, +5VDC
530-1580 DC Harness, +5VDC, -5VDC, +12VDC, -12VDC

SYS-26

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/180/280/480 & Sun-4/280/380
1/4" Tape Drive Option
PART #

230-1007
370-1061
370-1235
370-1076
370-1103
370-1103
370-1235
530-1249
530-1277
140-1010
530-1278
530-1279
813-1016

DESCRIPTION

Plastic Standoff, 1.0 cm
Emulex MT02 Tape Controller
Emulex MT02 Tape Controller
45/60MB 1/4" Tape Drive, Wangtech 5099EN24 (obsolete)
45/60MB 1/4" Tape Drive, QIC-11/24, Wangtech 5099EN24
45/60MB 1/4" Tape Drive, QIC-11/24, Archive 5945C
Emulex MT02 Tape Controller
SCSI Bus Cable, SCSI Host Adapter to SCSI Tray
DC Harness, Emulex MT02 to Tape Drive
• Fuse, 5A (+5 VDC)
SCSI Bus Cable, Rear Panel to Emulex MT02
Tape Command Cable, Emulex MT02 to Tape Drive
Installation & Service Manual for the Sun-3/1BO Tape
Drive Option

Technical Volume II

SYS-27

PARTS BREAKDOWN

12/90

Sun-3/470 & Sun-4/370/470
12-Slot VMEbus Logic Enclosure
CODE

PART #

1
1
1
2
2
3
4
5
6
6
NS
NS
7
8
7&8
NS
NS
9
10
NS
NS
NS
11
NS
NS
NS
NS
12
12
NS
NS
NS
13
14
NS
15
16
17
17

501-1439
501-1598
501-1832
340-1877
540-1846
340-1898

1

330-1192
330-1210
330-1284
340-2249
340-1901
540-1731
540-1849
540-1731
240-0558
240-0557
340-1871
540-1748
330-1212
330-1213
340-1936
540-1751
530-1482
540-1732
530-1640
370-1732
240-8503
340-2129
340-1878
540-1848
540-1749
530-1480
501-1493
140-1019
530-1494
340-1892
300-1047
300-1089

DESCRIPTION

12-Slot Backplane. Pressfit (obsolete) 1
12-Slot Backplane. Pressfit
12-Slot Backplane. Pressfit with DC Harness Cutout
Side Cover (obsolete)
Side Cover
Top Cover
Refer to Codes 18-24
Front Bezel Blank Insert
Front Bezel Half-Height Insert
Front Bezel Full-Height Insert
SCSI Tray Full-Height Bezel
SCSI Tray Half-Height Bezel
Front Bezel Assembly (obsolete)
Front Bumper (obsolete)
Front Bezel & Bumper Assembly
• MinibaJl Receptacle
• MinibaJl Fastener
Front EMI Shield. without Switch Assembly
Switch Assembly
• Plastic Remote Switch
• Plastic Remote Switch Block
• Remote Switch Housing
Fan Tray Assembly (Fans are Rivetted to the Tray)
• Fan Tray DC Harness for Fan 540-1732
• DC Fan Assembly. 150 CFM
• Fan Tray DC Harness for Fan 370-1732
• DC Fan Assembly. 150 CFM
Caster (obsolete)
Caster
Rear Bezel (obsolete)
Rear Bezel
Rear Bumper
Backplane to Interface PCB DC Harness
Interface PCB (SCSI Bus & DC Power)
• 15 Amp Fuse
SCSI Bus Internal Command Cable. 25.4 cm
SCSI PCB Cover
925 Watt Power Supply
925 Watt Power Supply

The Sun 4400 CPU is not supported in the 501-1439 Backplane.

SYS-28

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/470 and Sun-4/370/470
12-Slot VMEbus Logic Enclosure

L-_---2

4

~~5
6

2
12

7

8

Field Engineer Handbook - Technical Volume II

SYS-29

12/90

PARTS BREAKDOWN

Sun-3/470 & Sun-4/370/470

Technical Volume II

SYS-31

PARTS BREAKDOWN

12/90

Sun-3/470 & Sun-4/370/470

Peripheral Tray

DUAL DISK
DRIVES

DISK DRIVE and TAPE DRIVE

23

20
24

SYS-32

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/470 & Sun-4/370/470
12-810t VMEbus Logic Enclosure - Continued
CODE

PART #

18
19
20
20
21
21
21
22
23
23
23
23
23
24
NS
NS
NS

340-1903
501-1496
530-1498
530-1729
370-1230
370-1319
370-1319
530-1500
370-1206
370-1247
370-1297
370-1205
370-1347
530-1499
530-1698
530-1249
530-1593
800-3255

DESCRIPTION

Peripheral Tray Base
Peripheral Tray Interface PCB
Internal SCSI Bus Cable, 1.2M (obsolete) 1
Internal SCSI Bus Cable, 1.2M 1
327MB Disk Drive, Imprimis/CDC 77777126
669MB Disk Drive, Micropolis 1588-15
669MB Disk Drive, Maxtor XT -8760S
Internal SCSI Bus Cable, 1.2M 1
150MB Tape Drive, Full-Height, QIC-150
45/60MB Tape with MT02, Full-Height, QIC-11/24
2.3GB 8 mm Tape Drive, Full-Height
150MB Tape Drive, Half-Height, QIC-150
644MB CD ROM, Half-Height
Peripheral Tray DC Harness
DC "Y" Harness, Half-Height Peripherals
External SCSI Cable, DD-50SA to DD-50SA, 1.0M
External SCSI Cable, 50-Pin SCSI-2 to DD-50SA, 1.0M
12-Slot Office Pedestal Field Service Manual

1 Tape only and Disk with Tape option trays use internal SCSI cable

530-1498 or 530-1729.
1

Disk only, Dual Disk, and Empty option trays use internal SCSI cable
530-1500.

Technical Volume II

SYS-33

PARTS BREAKDOWN

12/90

Sun-4/11 0/31 0
3-Slot VMEbus Logic Enclosure
PART #

140-1019
140-1030
150-1042
150-1051
180-1010
180-1097
180-1117
180-1125
300-1022
300-1022
330-1067
330-1069
330-1071
330-1089
330-1144
340-1545
370-1106
370-1178
501-1127
540-1384
540-1418
540-1419
501-1193
540-1455
540-1535
540-1541
540-1542
800-2126

SYS-34

DESCRIPTION

Fuse. 15A (115V)
Fuse. 6.3A (240V)
Fusecarrier (115V)
Fusecarrier (240V)
AC Power Cord. Coiled. AC Output Receptacle to Monitor
AC Power Cord (115V)
AC Power Cord. AC Output Receptacle to Monitor
AC Power Cord (240V)
325 Watt Power Supply. Summit
325 Watt Power Supply. Brown
End Panel. 42 cm X 11 cm
Front Bezel
Side Panel. 42 cm X 59 cm
Side Panel Screw
Backplane Shield
Air Filter Assembly
AC Switch & Fuse (obsolete)
AC Switch & Fuse & Filter Assembly
3-Slot VMEbus Backplane. Pressfit
DC Fan Tray & Power Supply Module Assembly (115V)
Power Supply Module Assembly (115V)
DC Fan Tray Assembly. 4 Fans
• Fan Controller PCB
• DC Fan Assembly. 26 CFM
3-Slot Foot Assembly
Power Supply Module Assembly (240V)
DC Fan Tray & Power Supply Module Assembly (240V)
Field Service Manual for the Sun 3-Slot Logic Enclosure

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-4/150/350
6-Slot VMEbus Logic Enclosure
PART #

140-1019
140-1030
150-1042
150-1051
150-1217
180-1010
180-1097
180-1117
180-1125
330-1068
330-1070
330-1071
330-1089
330-1143
340-1547
370-1106
370-1178
501-1128
530-1352
530-1353
540-1381
540-1409
501-1233
540-1471
540-1410
300-1020
340-1454
540-1475
800-1944

DESCRIPTION

Fuse. 15A (115V)
Fuse. 6.3A (240V)
Fusecarrier (115V)
Fusecarrier (240V)
AC Line Filter (obsolete) 1
AC Power Cord. Coiled. AC Output Receptacle to Monitor
AC Power Cord (115V)
AC Power Cord. AC Output Receptacle to Monitor
AC Power Cord (240V)
End Panel. 42 cm X 17 cm
Front Bezel
Side Panel. 42 cm X 59 cm
Side Panel Screw
Backplane Shield
Air Filter Assembly
AC Switch & Fuse (obsolete) 1
AC Switch & Fuse & Filter Assembly 1
6-Slot VMEbus Backplane
AC Harness. AC Switch to Line Filter (obsolete) 1
AC Harness. Line Filter to Power Supply (obsolete) 1
DC Fan Tray & Power Supply Module Assembly (115V)
DC Fan Tray Assembly
• Fan Controller PCB
• DC Fan Assembly. 60 CFM
Power Supply Module Assembly (115V)
• 575 Watt Power Supply
• Power Supply Cover
6-Slot Foot Assembly
Field Service Manual for the Sun 6-Slot Logic Enclosure

1 When AC Switch. 370-1106. is replaced with AC Switch. 370-1178.

remove the AC Line Filter. 150-1217. AC Wire Harness. 530-1352.
and AC Wire Harness 530-1353.

Technical Volume II

SYS-35

PARTS BREAKDOWN

12/90

Sun-4/330
5-Slot VMEbus Logic Enclosure
CODE

PART #

1
NS
2
NS
NS
3
3
4
5
6
NS
NS
NS
NS
7
8
9
10
NS
11
NS
NS
NS
NS
NS
12
13
NS
NS
NS
NS
NS
NS
NS
NS
14
14

330-1178
330-1180
540-1760
530-1465
530-1468
540-2029
540-1788
540-1811
530-1470
340-1772
501-1432
501-1416
120-1608
530-1434
540-1789
530-1469
540-1787
540-1757
340-1800
540-1758
370-1206
370-1230
370-1319
370-1319
530-1466
150-1129
340-1792
340-1793
340-1677
340-1784
340-1676
501-1354
540-1800
240-1605
150-1323
300-1034
300-1072
800-3272

DESCRIPTION

Rear Cover
Cable Retainers
Fan and Bracket Assembly
DC Harness. Power Supply to Peripherals & Fans 1
• Fan Harness 1
• Fan Assembly. Variable Speed Controlled
• Fan Assembly (obsolete)
• AC Receptacle
AC Input Harness
SCSI Terminator Access Panel
• SCSI IN Terminator PCB
• SCSI OUT Terminator PCB
• 220/330 Terminator
External SCSI Cable 45 cm. 50-Pin SCSI-2
Top Cover Assembly
AC Harness. Internal 2
Front Cover Assembly
Upper Drive Tray Assy
• Tape Filler Panel
Lower Drive Tray Assy
150MB Tape Drive. Ful.I-Height. QIC-150
327MB Disk Drive. Imprimis/CDC 77777126
669MB Disk Drive. Micropolis 1588-15
669MB Disk Drive. Maxtor XT-8760S
Internal SCSI Cable
AC Line Filter
Left Cover
Right Cover
6U Filler Panel
6U Side Cover
3U Top Cover
5-Slot VMEbus Backplane. Pressfit
Caster Plate and Stud
Caster Ball
AC On/Off Switch
520 Watt Power Supply (obsolete)
520 Watt Power Supply. Improved -12v output
Field Service Manual for the 5-Slot Logic Enclosure

Wire harnesses <530-1465-04. Rev 51. and <530-1468-03. Rev 50.
are NOT field repairable or replaceable. These lower revision harnesses
are soldered together. Replace both harnesses upon failure. Wire
harnesses >530-1465-04. Rev 51. and >530-1468-03. Rev 51. are
pluggable. 2 WIre harness 530-1469 is NOT field repairable or replaceable.
1

SYS-36

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-4/330

5-Slot VMEbus Logic Enclosure

8

9

3

4

13

14

Field Engineer Handbook - Technical Volume II

SYS-37

12/90

PARTS BREAKDOWN

This page intentionally left blank.

Technical Volume II

SYS-39

PARTS BREAKDOWN

12/90

Sun-4/370/470
12-Slot VMEbus Logic Enclosure
CODE

PART #

1
2
3
4
5
6
6
7
NS
NS
8
NS
NS
NS
9
10
NS
NS
NS
NS
11
12
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

501-1832
540-1846
300-1089
340-1898
330-1192
330-1210
330-1284
540-1939
240-0558
240-0557
340-2291
340-2292
340-xxxx
340-2444
540-xxxx
540-xxxx
530-1482
540-1732
530-1640
370-1732
340-2129
340-2293
540-1848
540-1749
530-1676
370-1319
370-1319
370-1206
370-1297
370-1205
370-1347
530-1675
530-1698
150-1346
530-xxxx
530-xxxx
800-3255

DESCRIPTION

12-Slot Backplane, Press fit with DC Harness Cutout
Side Cover
925 Watt Power Supply
Top Cover
Blank Bezel Insert
Front Bezel Half-Height Insert
Front Bezel Full-Height Insert
Front Bezel Assembly
• Miniball Receptacle
• Miniball Fastener
Front EMI Cover, without Switch Assembly
Blank EMI Cover Filler Panel
Half-Height EMI Cover Filler Panel
Peripheral Mounting Bracket
Switch Assembly
Fan Tray Assembly 1.
• Fan Tray DC Harness for Fan 540-1732
• DC Fan Assembly, 150 CFM
• Fan Tray DC Harness for Fan 370-1732
• DC Fan Assembly, 150 CFM
Caster
Rear EMI Cover
Rear Bezel
Rear Bumper
Internal SCSI Bus Cable
669MB Disk Drive, Micropolis 1588-15
669MB Disk Drive, Maxtor XT -8760S
150MB Tape Drive, Full-Height, QIC-150
2.3GB 8 mm Tape Drive, Full-Height
150MB Tape Drive, Half-Height. QIC-150
644MB CD ROM, Half-Height
Peripheral Tray DC Harness
Peripheral Tray DC "Y" Harness
External SCSI-2 Terminator
SCSI Cable, DD-50SA to 50-Pin SCSI-2, xx cm
SCSI Cable, 50-Pin SCSI-2 to 50-Pin SCSI-2, xx cm
12-Slot Office Pedestal Field Service Manual

1. The nine fan assembly is removable to allow access to the fan tray screen

during routine preventive maintenance.

SYS-40

Field Engineer Handbook

PARTS BREAKDOWN

12/90

Sun-4/370/470
12-Slot VMEbus Logic Enclosure

3

2

Field Engineer Handbook - Technical Volume II

SYS-41

12/90

PARTS BREAKDOWN

Sun-4/370/470

12

Technical Volume II

SYS-43

PARTS BREAKDOWN

12/90

Sun-4/390/490
SCSI Peripheral Trays
Versions 1 & 2

540-1865-01
(Prior to April 1990)
6

Version 3

540-1865-02
(After April 1990)

7

SYS-44

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-4/390/490
SCSI Peripheral Trays
CODE

PART #

DESCRIPTION

1
2
3
4
5
6

540-1865-01
340-2000
530-1474
240-1202
530-1507
340-1832
340-1999

SCSI Tray, Versions 1 & 2 (Shipped Prior to April 1990)
SCSI Tray
SCSI Bus Cable, 73 cm, Internal
• Peripheral Mounting Screw, #6-32 x 5/8"
• SCSI Power Cable, Internal
SCSI Tray Top Cover
Peripheral Cover Plate

7
8
9
NS
10
11
11
12
13
14
15
16

540-1865-02
340-2143
530-1642
530-1641
530-1638
340-2145
340-2146
340-2305
240-1372
340-2148
240-0258
340-2144
240-0646

SCSI Tray, Version 3 (Shipped After April 1990)
• SCSI Tray
• SCSI Bus Cable, 180 cm
SCSI Power Cable, Internal
DC Power "Y" Cable, 15 cm
Front Plate
Full-Height Peripheral Blank Plate
• Half-Height Peripheral Blank Plate
• M4 007 x 10 mm Screw
Peripheral Mounting Bracket
#6-32 x 3/8" Peripheral Mounting Screw
SCSI Tray Top Cover
Cable Clamp

NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

370-1205
370-1206
370-1297
370-1347
530-1435
530-1593
530-1508
530-1501
530-1502
530-1568

150MB Tape Drive, Half-Height, QIC-150
150MB Tape Drive, Full-Height, QIC-150
203GB 8 mm Tape Drive, Full-Height
644MB CD ROM, Half-Height
External Cable, 50-Pin SCSI-2 to DD-50SA, 200M
External Cable, 50-Pin SCSI-2 to DD-50SA, 100M
External Cable, 50-Pin SCSI-2 to SCSI-2, 80 cm
External Cable, 50-Pin SCSI-2 to Centronics, 200M
External Cable, Centronics to Centronics, 105
External Cable, 50-Pin SCSI-2 to Centronics, 400M

•
•
•
•
•
•
•
•
•

•
•
•

Technical Volume II

SYS-45

12/90

PARTS BREAKDOWN

Sun-4/390/490
16-Slot VMEbus Logic Enclosure
CODE

PART #

1

540-1719
540-1840
530-1560
530-1561
150-1393
240-1614
340-1833
240-1372
150-1397
530-1506
530-1534
300-1065
300-1047
501-1498
501-1597
540-1869
180-1189
180-1190
230-0203
240-0146
800-3265

2
3
4
5
6
7
7

8
8
NS
NS
NS
NS
NS

DESCRIPTION

Blower Assembly, 2 Blowers
• Centrifugal Fan Assembly
• Cable, 32.5 cm, Fan to Terminal
• Cable, 86.5 cm, AC Input to Terminal
• Capacitor
• Terminal Block
Front RFI Shield
M4 0.7 x 10 mm SEM Screw
Indicator LED
Indicator LED Cable
SCSI Power Cable
1200 Watt Power Supply
925 Watt Power Supply (obsolete)
16-slot Backplane, Pressfit (obsolete)
16-slot Backplane, Pressfit
Load Resistor Assembly (obsolete) 1
Power Cord (230V)
Power Cord (240V)
Cable Tie, 4"
Cable Clamp
Sun 16-S/ot Logic Enclosure Field Service Manual

1 The Load Resistor Assembly is only required with the 925 Watt Power

Supply.

SYS-46

Field Engineer Handbook

PARTS BREAKDOWN

12/90

Sun-4/390/490

16-Slot Logic Enclosure

7

Field Engineer Handbook - Technical Volume II

SYS-47

12/90

PARTS BREAKDOWN

Sun386i/150/250
3-810t ATbus Logic Enclosure
PART #

230-1115
330-1118
350-1001
350-1005
350-1006
350-1007
370-1150
370-1158
370-1184
370-1271
530-1370
530-1375
530-1376
530-1377
530-1380
530-1381
530-1411
540-1612
540-1613
555-1006
300-1032
300-1046
340-1618

DESCRIPTION

Clip, Quarter Turn
Rear Bezel
Front Bezel Assembly
Panel Assembly, Right
Panel Assembly, Top
Panel Assembly, Left
3 1/2" Floppy Drive
DC Fan Assembly, 100 CFM
DC Fan Assembly, 105 CFM (obsolete)
DC Fan Assembly, 94 CFM
AC Power Cord (115V)
DC Harness, CPU to Floppy Drive & SCSI Disk Drive
SCSI Bus Cable, Internal
Floppy Data Cable
DC Wire Harness, CPU to Fan
SCSI Bus Terminator
AC Power Cord (UK)
Speaker Assembly
DC Power Indicator LED
265 Watt Power Supply Assembly
• 265 Watt Power Supply with 90 VDC Output (obsolete)
• 265 Watt Power Supply
• Power Supply Air Deflector

Technical Volume II

SYS-49

PARTS BREAKDOWN

12/90

Sun386i/150/250
Disk Drive Options
PART #

DESCRIPTION

555-1004 91 MB SCSI Disk Drive Assembly
330-1146 • Mounting Bracket
330-1158 • Drive Removal Handle
370-1148 • 91 MB Disk Drive, Imprimis/CDC 77765863
530-1376 SCSI Bus Cable, Internal
530-1381 SCSI Bus Terminator
555-1005
330-1146
330-1158
370-1153
530-1376
530-1381

327MB SCSI Disk Drive Assembly
• Mounting Bracket
• Drive Removal Handle
• 327MB Disk Drive, Imprimis/CDC 77777107
SCSI Bus Cable, Internal
SCSI Bus Terminator

555-1059 155MB SCSI Disk Drive Assembly
330-1146 • Mounting Bracket
330-1158 • Drive Removal Handle
370-1191 • 155MB Disk Drive, Imprimis/CDC 77774677
530-1376 SCSI Bus Cable, Internal
530-1381 SCSI Bus Terminator

SYS-50

Field Engineer Handbook

12/90

PARTS BREAKDOWN

This page intentionally left blank.

Technical Volume II

SYS-51

PARTS BREAKDOWN

12/90

Sun-3/aO

16

SYS-52

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-3/80
1-Slot P4 Bus Logic Enclosure
CODE

PART #

1
1
1
2
2
3
NS
4
5
6
7
NS
8
NS
9
10
11
12
13
14
14
NS
NS
15
16
17
NS
18
19
NS

240-1151
240-1206
240-1761
540-1710
330-1173
540-1701
230-1140
330-1214
330-1167
300-1038
240-1530
340-1768
330-1242
340-2045
370-1207
530-1452
530-1441
540-1703
330-1165
540-1702
540-1993
230-1141
230-1242
370-1200
240-1141
330-1228
340-1768
530-1453
530-1451
340-1859
800-3224

DESCRIPTION

Cover Screw. M4 0.7 x 10 mm (obsolete)
Cover Screw. M4 0.7 x 10 mm (obsolete)
Cover Screw. #8-32 x 112"
Rear Panel Assembly (obsolete)
Rear Panel Assembly
Base Assembly
• LED Mounting Clip
• Front Foot
• Rear Foot
Power Supply
Screw. M3 x 6 mm
Floppy Drive Mounting Bracket (obsolete)
Floppy Drive Mounting Bracket
Floppy Drive Filler Panel
Floppy Drive
Floppy Drive Command Cable
Floppy Drive Power Cable
Speaker and LED Assembly
Speaker Housing
Top Cover Assembly (obsolete)
Top Cover Assembly
• Tinnerman Clip (obsolete)
• Tinnerman Clip
104MB Disk Drive. Quantum 105S
Screw. #6-32 x 1/4"
Disk Drive Mounting Bracket
Disk Drive Mounting Bracket (obsolete)
DC Power Harness
Disk Command Cable
Blank Rear Panel
Sun-3/80 Field Service Manual

Technical Volume"

SYS-53

12/90

PARTS BREAKDOWN

Sun-4/20
1-Slot Logic Enclosure
PART #

DESCRIPTION

330-1298 17" Monitor Control Panel Cover
530-1677 Serial Port Breakout Cable, OB-25 Male to 2 OB-25 Females
530-1696 Ethernet Adapter Cable, 2.0M
530-1702 Audio Adapter Cable
570-1057 17" Greyscale Monitor, FCC-A/VCCI-1
570-1044 17" Greyscale Monitor, FCC-BNCCI-2
814-5039 SPARCstation SLC Installation & Repair Guide

SYS-S4

Field Engineer Handbook

PARTS BREAKDOWN

12/90

Sun-4/20
1-810t Logic Enclosure

Technical Volume II

SYS-55

12/90

PARTS BREAKDOWN

Sun-4/40
2-810t 8Bus Logic Enclosure

SYS-56

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-4/40
2-810t 8Bus Logic Enclosure
CODE

PART #

1
2
3
3
4
5
6
7
8
9
10
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

540-1998
300-1055
370-1327
370-1327
530-1451
330-1214
530-1643
540-1973
330-1304
370-1354
330-1313
240-1612
330-1322
340-2297
340-2371
410-1018
530-1594
530-1662
540-1982
540-1999
340-2135
240-1789
540-2100
330-1327
540-2090
800-5038
800-5698

DESCRIPTION

Top Cover Assembly
65 Watt Power Supply & DC Harness
207MB Disk Drive, Quantum 210S
207MB Disk Drive, Maxtor LXT -213SY
SCSI Disk Cable
Rubber Foot
Floppy Disk Cable
Speaker Assembly
LED Light Pipe
3.5" Floppy Disk Drive
Cable Management Clip (obsolete)
#2-56 x 1/4" Screw, CPU SCSI Connector
LED Lens
SBus Cover Plate
Cable Management Bracket
Reusable Field Service System Transit Case
Audio Cable, Mini-Din to Mini-Jack
RS-232 Cable, External, 1.0 M, Mini-Din to DB-25
Top Cover Lockbox Assembly
Peripherals Mounting Bracket Assembly
• Peripherals Mounting Bracket
• Captive Screw, M3.5 0.6 x 10 mm
Vertical Support
• Vertical Support
• Foot Assembly
SPARCstation IPC Field Service Manual
RTF SPARCstation IPC Field Service Manual

Technical Volume II

SYS-57

PARTS BREAKDOWN

12/90

Sun-4/60/65
3-Slot SBus Logic Enclosure

SYS-58

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-4/60/65
3-Slot SBus Logic Enclosure
CODE

PART #

1
1
1
2
2
3
NS
4
5
6
7
NS
8
NS
9
10
11
12
13
14
14
NS
NS
15
16
17
NS
18
19
NS
NS

240-1206
240-1531
240-1761
540-1708
330-1168
540-1701
230-1140
330-1214
330-1167
300-1038
240-1530
340-1768
330-1242
340-2045
370-1207
530-1452
530-1441
540-1703
330-1165
540-1702
540-1993
230-1141
230-1242
370-1200
240-1141
330-1228
340-1768
530-1453
530-1451
340-1859
530-1594
800-4101
800-4918

DESCRIPTION

Cover Screw, M4 0.7 x 10 mm (obsolete)
Cover Screw, M4 0.7 x 10 mm (obsolete)
Cover Screw, #8-32 x 1/2"
Rear Panel Assembly (obsolete)
Rear Panel Assembly
Base Assembly
• LED Mounting Clip
• Front Foot
• Rear Foot
Power Supply
Screw, M3 x 6 mm
Floppy Drive Mounting Bracket (obsolete)
Floppy Drive Mounting Bracket
Floppy Drive Filler Panel
Floppy Drive
Floppy Drive Command Cable
Floppy Drive Power Cable
Speaker and LED Assembly
Speaker Housing
Top Cover Assembly (obsolete)
Top Cover Assembly
• Tinnerman Clip (obsolete)
• Tinnerman Clip
104MB Disk Drive, Quantum 105S
Screw, #6-32 x 1/4"
Disk Drive Mounting Bracket
Disk Drive Mounting Bracket (obsolete)
DC Power Harness
Disk Command Cable
Blank Rear Panel
Audio Cable, Mini-Din to Mini-Jack
SPARCstation 1 Field Service Manual
Addendum SPARCstation 1 Field Service Manual

Technical Volume II

SYS-59

PARTS BREAKDOWN

12/90

Sun-4!75
3-Slot SBus Logic Enclosure
9

17

SYS-60

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Sun-4!75
3-810t 8Bus Logic Enclosure
CODE

PART #

1
2
3
NS
4
5
6
7
8
NS
NS
9
10
11
12
13
14
15
NS
NS
16
16
17
18
19
20
NS

240-1761
330-1168
540-2071
230-1140
330-1214
330-1167
300-1038
240-1530
330-1242
340-2045
330-1344
370-1207
530-1452
530-1679
540-2072
330-1165
540-1802
540-1993
230-1141
230-1242
370-1327
370-1327
240-1141
330-1343
530-1453
530-1451
530-1594
800-5166

DESCRIPTION

Cover Screw, #8-32 x 1/2"
Rear Panel Assembly
Base Assembly
• LED Mounting Clip
• Front Foot
• Rear Foot
Power Supply
Screw, M3 x 6 mm
Floppy Drive Mounting Bracket
Floppy Drive Filler Panel
Floppy Drive Foam Gasket
Floppy Drive
Floppy Drive Command Cable
Floppy Drive Power Cable
Speaker and LED Assembly
Speaker Housing
DC Fan Assembly
Top Cover Assembly
• Tinnerman Clip (obsolete)
• Tinnerman Clip
207MB Disk Drive, Quantum 210S
207MB Disk Drive, Maxtor LXT -213SY
Screw, #6-32 x 1/4"
Disk Drive Mounting Bracket
DC Power Harness
Disk Command Cable
Audio Cable, Mini-Din to Mini-Jack
SPARCstation 2 Field Service Manual

Technical Volume II

SYS-61

PARTS BREAKDOWN

RACK

12/90

PARTS BREAKDOWN

Rack
76-inch Data Center Cabinet & Data Center
Expansion Cabinet ........................
Half-Height Rack .......................... ,
56-inch Data Center Cabinet & Data Center
Expansion Cabinet ........................

Field Engineer Handbook - Technical Volume II

3
5
6

12/90

PARTS BREAKDOWN

This page intentionally left blank.

RACK-2

Field Engineer Handbook

12/90

PARTS BREAKDOWN

76-lnch Data Center Cabinet
Data Center Expansion Cabinet
Option 960
PART #

DESCRIPTION

180-1149 32Amp IEC-309 AC Receptacle (240V)
300-1011 AC Power Sequencer (115V)
340-0530 19" Logic Enclosure Support Rail Bracket (obsolete)
340-1283 19" Logic Enclosure Support Rail Assembly (obsolete)
340-1284 Keyswitch Panel. 7" x 19" (obsolete)
340-1285 Panel, 7" x 19"
340-1286 Panel. 3.5" x 19"
340-1287 Panel. 24.5" x 19"
340-1441 Keyswitch Panel. 1.5" x 19"
340-1442 Tape Drive Filler Panel. 1.5" x 19"
340-1485 19" Logic Enclosure Filler Panel, xxx x 19"
340-1487 Rear Panel with Cable Cutout, 22.7" x 19"
340-1489 Panel. 1.5 x 19"
340-1490 Panel. 10.5" x 19"
340-1522 19" Logic Enclosure Support Rail (obsolete)
340-1554 Panel, 19.6" x 19"
340-1595 Perforated Panel, 20" x 19"
340-1597 Panel. 5.25 x 19"
340-1662 892MB Disk Drive Front Panel
340-1700 Front Panel. 3.5" x 19" x 40 mm
340-1701 Front Panel. 10.5" x 19" x 40 mm
340-1715 Filler Panel for 340-1662
370-1027 AC Power Sequencer (230V) (obsolete)
370-1045 Blower Assembly
370-1053 76" rack with Rear Door
370-1105 76" rack without Rear Door
370-1126 AC Power Sequencer (240V) (obsolete)
370-1155 AC Power Sequencer (230V)
370-1156 AC Power Sequencer (240V)

Technical Volume II

RACK-3

12/90

PARTS BREAKDOWN

76-lnch Data Center Cabinet
Data Center Expansion Cabinet
Option 960
PART #

DESCRIPTION

530-1298 AC Power Cord, Fan Assembly (115V)
530-1303 Keyswitch Cable, 2.75M
530-1328 AC Power Cord, Fan Assembly (230V)
530-1343 AC Power Cord, 19" Logic Enclosure (240V)
530-1344 AC Power Cord, Fan Assembly (240V)
530-1346 AC Power Cord, Fujitsu M2444AC Tape Drive (240V)
530-1347 AC Power Cord, Fujitsu M2361A Disk Drive (240V)
530-1348 AC Power Cord, Fujitsu M2444AC Tape Drive (230V)
530-1349 AC Power Cord, Fujitsu M2361A Disk Drive (230V)
530-1350 AC Power Cord, CDC 92181 Tape Drive (230V)
530-1351 AC Power Cord, 19" Logic Enclosure (230V)
540-1285 Keyswitch Assembly
540-1428 AC Fan Assembly (115V)
340-1491 Fan Bracket
370-0550 • AC Fan (115V)
540-1503 AC Fan Assembly (230V)
340-1491 Fan Bracket
370-1124 • AC Fan (230V)
540-1568 AC Fan Assembly (240V)
340-1491 Fan Bracket
370-1124 • AC Fan (240V)
540-1585 19" Logic Enclosre Support Rail Assembly
340-1583 • 19" Logic Enclosure Support Rail Bracket
340-1584 • 19" Logic Enclosure Support Rail
560-1113 19" Logic Enclosure Mounting Hardware Kit

RACK-4

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Half-Height Rack
Option 950
PART #

340-1434
340-1468
370-1060
370-1080
370-1093
370-1114
370-1115
530-1079
530-1079
530-1080
530-1209
530-1209
530-1210
540-1369
530-1256
340-1433
540-1397
340-1433
340-1447

DESCRIPTION

Rear Door
Front Door Plug
Half-Height Rack. 40" x 19" x 30"
CDC 92181 1/2" Tape Drive Horizontal Mounting Kit
AC Outlet Strip (115V)
CDC 92181 1/2" Tape Drive Operator Panel Cover
CDC 92181 1/2" Tape Drive Operator Panel
External Tape Command Cable. 0.7M (obsolete)
External SMD Command Cable. 0.7M (obsolete)
External SMD Data Cable. 0.7M (obsolete)
External Tape Command Cable. 2.0M
External SMD Command Cable. 2.0M
External SMD Data Cable. 2.0M
Cable Panel Assembly. 1/2" Tape Drive
• Internal 1/2" Tape Command Cable
• Cable Panel
Cable Panel Assembly. 112" Tape Drive. Blank
• Cable Panel
• Filler Panel

Technical Volume II

RACK-5

PARTS BREAKDOWN

12/90

56-Inch Data Center Cabinet
Data Center Expansion Cabinet
Option 955
CODE

PART #

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
19
20
20
21
22
23
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

540-1857
540-1947
540-1859
540-1858
240-1630
340-1840
540-1285
340-1885
240-1372
540-1718
340-1881
340-1848
340-1886
370-1210
240-1373
230-1181
340-1884
240-1207
370-1155
370-1156
540-1929
540-1930
340-1845
340-2047
240-1655
230-1166
230-1170
230-1177
240-1633
240-1634
240-1738
240-1739
240-1748
340-1835
340-1913
340-2057
340-2138
530-1303
800-3259

RACK-6

DESCRIPTION

Vented Panel Assembly
1/2" Tape Panel Assembly with Cutout
Cap Panel Assembly
Upper Panel Assembly, 1/2" & 1/4" Tape, Hinged
#6-32 Ballstud
Top Panel
Keyswitch Assembly
Side Restraint Bracket, Upper
M4 0.7 x 10 mm Sem Screw
Frame Assembly
Hinge Bracket
Side Panel
Side Restraint Bracket. Lower
Caster
M4 0.7 Kepnut
Leveler Foot
Anti-Tilt Panel
#10-32 x 1/2" Sem Screw
Power Sequencer (230V)
Power Sequencer (240V)
Fan Assy (230V)
Fan Assy (240V)
Rear Panel
Kick Panel
#10-32 x 3/4" Screw
Cable Tie 5.5", Reuseable
Cable Tie 10", Reuseable
Snap In Clip
Washer. Flat. 1.00
Washer, Lock, 3/8"
3/8 x 16 x 4.0 Screw
3/8" x 16 x 7.0 Screw
3/8" x 16 x 4.0 Screw
16-slot Chassis Support Rail, Left
Filler Panel, 5.2" x 19"
16-slot Chassis Support Rail, Right
Ballast, 30 Ibs
Remote Keyswitch Cable

Sun 56-inch Data Center Cabinet and Data Center
Expansion Cabinet Field Service Manual

Field Engineer Handbook

PARTS BREAKDOWNS

12/90

56" Server System Cabinet and Expansion System
6

12~

REAR VIEW

---+---12

17

Field Engineer Handbook - Technical Volume II

RACKS-7

PARTS BREAKDOWN

OPTION

ARTS BREAKDOWN

12/90

External Peripheral Option
OPTION

DESCRIPTION

55
55EX

71 MB Disk Mass Storage Subsystem

56
60

71 MB Disk & 60MB Tape Mass Storage Subsystem
65MB Disk Subsystem ....................... .

61
62
73

65MB Disk & 20MB Tape Subsystem ........... .
65MB Expansion Disk Subsystem .............. .
20MB Tape Subsystem ...................... .

63
64

130MB Disk Subsystem ...................... .

65

130MB Disk & 20MB Tape Subsystem .......... .

63
64

130MB Disk Subsystem ...................... .
130MB Expansion Disk Subsystem ............. .
2x 130MB Disk Subsystem .................... .

65
66
67

71 MB Expansion Disk Mass Storage Subsystem ...

130MB Expansion Disk Subsystem ............. .

7
7
7

8
8
8
8
9
9
9
10

130MB SMD Disk Subsystem .................. .
130MB Expansion SMD Disk Subsystem ......... .

10
10
11
11

130MB SMD Disk Subsystem .................. .

11

D169EX 130MB Expansion SMD Disk Subsystem ......... .

11

D474

D169

380MB SMD Disk Subsystem .................. .

12

D474EX 380MB Expansion SMD Disk Subsystem ......... .

12

68
69
620
621

380MB SMD Disk Subsystem .................. .
380MB Expansion SMD Disk Subsystem ......... .

12
12

380MB SMD Disk Subsystem ................. .
380MB Expansion SMD Disk Subsystem ......... .

12

75

1600 BPI 1/2" Tape Drive .................... .

12
13

670

1600 BPI 1/2" Tape Drive .................... .

13

TR

1600 BPI 1/2" Tape Drive .................... .

78

6250 BPI 1/2" GCR Tape Drive ................ .

13
14

675

6250 BPI 1/2" GCR Tape Drive ................ .

14

180

SunButtons ................................ .

16

Field Engineer Handbook - Technical Volume II

PARTS BREAKDOWN

12/9

External Peripheral Option - Continued
OPTION

190
501
503
511
504
505
514
506
507
509
510
516
526
527
530
539
550
552
558
561
563
565
566
601
602
603
605
606
615

OPT-2

DESCRIPTION

SunDials 00000000000000000000000000000000000000
71 MB Disk Mass Storage Subsystem 0............. 0
71 MB Expansion Disk Mass Storage Subsystem ..... 0
71 MB Disk & 60MB Tape Mass Storage Subsystem 0.. 0
141 MB Disk Mass Storage Subsystem ... 0...... 0. ..
141 MB Expansion Disk Mass Storage Subsystem .....
141 MB Disk & 60MB Tape Mass Storage Subsystem . ..
327MB Disk Mass Storage Subsystem 00.. 0..... 00o.
327MB Expansion Disk Mass Storage Subsystem .....
2x 327MB Expansion Disk Mass Storage Subsystem . ..
2x 327MB Disk Mass Storage Subsystem . . . . . . . . . . ..
327MB Disk & 60MB Tape Mass Storage Subsystem
327MB Disk External Storage Module .... 0. 0. 000... 0
327MB Disk External Expansion Module o. 00. 0. 0. 0. ..
2x 327MB Disk External Storage Module 0. 0. 000. 0. 000
327MB Disk & 150MB Tape External Storage Module 00
104MB Desktop Disk Pack ......... 0....... 0. 0.' 000
207MB Desktop Disk Pack ......... 0......... 0... ,
644MB Desktop SunCD Pack 0. 0. 0. 0. 0. 0. 0. 0. 0000..
669MB Disk External Storage Module . 00.. 000. 0000o.
2x 669MB Disk External Storage Module .. 0.. 00.. 0. ..
669MB Disk & 150MB Tape External Storage Module ..
669MB Disk & 203GB Tape External Storage Module ...
130MB Disk Mass Storage Pedestal
0. 0. 0. 000.. 0. 0
130MB Expansion Disk Mass Storage Pedestal ..... o.
2x 130MB Disk Mass Storage Pedestal ... 0. 0. 0. 0... 0
280MB Disk Mass Storage Pedestal .... 0000....... 0
2x 280MB Disk Mass Storage Pedestal 0.. 00.. 000. 0
688MB Disk Mass Storage Pedestal o. 0.. 0. 0. 0. 000. 0
o.

o.

16
17
17
17
18
18
18
19
19
19
19
19
20
20
20
20
22
22
24
26
26
26
26
27
27
27
29
29
31

Field Engineer Handbook

PARTS BREAKDOWN

2/90

External Peripheral Option - Continued
OPTION

616
625
626
629
630
631
641
642
643
644
645
646
660
680
682
683
684
706A
707 A
709A
710A
716A
717A
719A
720A
731
732
733
734

DESCRIPTION

2x 688MB Disk Mass Storage Pedestal ..............
575MB SMD Disk Subsystem ..................... ,
575MB Expansion SMD Disk Subsystem ............
892MB SMD Disk Subsystem ..................... ,
892MB Expansion SMD Disk Subsystem ............
2x 892MB SMD Disk Subsystem ...................
892MB SMD Disk Subsystem . . . . . . . . . . . . . . . . . . . . ..
2x 892MB SMD Disk Subsystem ...................
3x 892MB SMD Disk Subsystem ...................
4x 892MB SMD Disk Subsystem ...................
892MB Expansion SMD Disk Subsystem without Tray ..
892MB Expansion SMD Disk Subsystem ....... , . . . ..
150MB Desktop Backup Pack ............... ,.....
Tabletop Front-Load 1/2" Tape Drive. . . . . . . . . . . . . ..
56" Rack Front-Load 1/2" Tape Drive ........ ,.....
56" Expansion Rack 1st Front-Load 1/2" Tape Drive ..
56" Expansion Rack 2nd Front-Load 1/2" Tape Drive .
1.2GB Disk Subsystem ................. , ........ ,
2x 1.2GB Disk Subsystem ........................
4x 1.2GB Disk Subsystem ........................
8x 1.2GB Disk Subsystem ........................
911 MB Disk Subsystem ..........................
2x 911 MB Disk Subsystem. . . . . . . . . . . . . . . . . . . . . . ..
4x 911 MB Disk Subsystem ....................... ,
8x 911 MB Disk Subsystem . . . . . . . . . . . . . . . . . . . . . . ..
688MB Sun Expansion Pedestal ................... ,
2x 688MB Sun Expansion Pedestal ................ ,
3x 688MB Sun Expansion Pedestal ................ ,
4x 688MB Sun Expansion Pedestal ... . . . . . . . . . . . . ..

Technical Volume II

31
33
33
34
34
35
35
35
35
35
35
35
36
39
39
39
39
44
44
44
44
45
45
45
45
48
48
48
48

OPT-3

PARTS BREAKDOWN

12/9(

External Peripheral Option - Continued
OPTION

741A
742A
743A
744A
745A
741L
742L
743L
744L
745L
941
942
943
944
945
946
D84
D84TC
D84EX
TC
LW110
LW220
LW240
SuniLW-1
Sun/LW-2
SuniLW-3
LW-1
LW-2
LW-3

OPT-4

DESCRIPTION

1.2GB Sun Expansion Pedestal ...............
2x 1.2GB Sun Expansion Pedestal . . . . . . . . . . . ..
3x 1.2GB Sun Expansion Pedestal ........... "
4x 1.2GB Sun Expansion Pedestal . . . . . . . . . . . ..
1.2GB Disk Standalone .......... . . . . . . . . . . ..
911 MB Sun Expansion Pedestal ............. "
2x 911 MB Sun Expansion Pedestal ............
3x 911 MB Sun Expansion Pedestal ............
4x 911 MB Sun Expansion Pedestal ............
911 MB Disk Standalone .....................
892MB SMD Disk Subsystem . . . . . . . . . . . . . . . ..
2x 892MB SMD Disk Subsystem . . . . . . . . . . . . . ..
3x 892MB SMD Disk Subsystem . . . . . . . . . . . . . ..
4x 892MB SMD Disk Subsystem . . . . . . . . . . . . . ..
892MB Expansion SMD Disk Subsystem wlo Tray.
892MB Expansion SMD Disk Subsystem ........
65MB Disk Subsystem ..................... "
65MB Disk & 20MB Tape Subsystem . . . . . . . . . ..
65MB Expansion Disk Subsystem . . . . . . . . . . . . ..
20MB Tape Subsystem ......................
115V LaserWriter I . . . . . . . . . . . . . . . . . . . . . . . . ..
220V LaserWriter I . . . . . . . . . . . . . . . . . . . . . . . . ..
240V LaserWriter I . . . . . . . . . . . . . . . . . . . . . . . . ..
115V LaserWriter I . . . . . . . . . . . . . . . . . . . . . . . . ..
220V LaserWriter I . . . . . . . . . . . . . . . . . . . . . . . . ..
240V LaserWriter I ........................ "
115V LaserWriter II .........................
220V LaserWriter II .........................
240V LaserWriter II .........................

52
52
52
52
52
54
54
54
54
54
56
56
56
56
56
56
57
57
57
57
58
58
58
58
58
58
59
59
59

Field Engineer Handboc

PARTS BREAKDOWN

2/90

External Peripheral Option - Continued
OPTION

RR127
RR128
RR129
RREXP
RREXP-P7
RR131
RR132
RR133
RR134
SPRN-400
IPC-FPY1
IPC-FPY2

DESCRIPTION

Empty Sun386i Expansion Unit . . . . . . . . . . . . . . ..
60MB Tape Sun386i Expansion Unit ............
327MB Disk & 60MB Tape Sun386i Expansion Unit
60MB Tape Sun386i Expansion Unit ............
327MB Disk & 60MB Tape Sun386i ............
155MB Disk Add-on Sun386i Options ..........
60MB Tape Add-on Sun386i Options ..........
91 MB Disk Add-on Sun386i Options...........
327MB Disk Add-on Sun386it Options. . . . . . . . ..
SPARCprinter..............................
Single Floppy Subsystem ....................
Dual Floppy Subsystem . . . . . . . . . . . . . . . . . . . . ..

60
60
60
60
60
61
61
61
61
62
63
63

GRAPHIC OPTION
GT Graphics Tower ................................... 64

Technical Volume II

OPT-5

12/90

PARTS BREAKDOWN

This page intentionally left blank.

OPT-6

Field Engineer Handbook

12/90

PARTS BREAKDOWN

55

55 EX

56

71 MB Disk

71 MB Disk
Expansion

71 MB Disk
60MB Tape

Mass Storage Subsystem (Sun-2 Shoebox)
PART #

180-1097
180-1125
370-1010
370-1011
370-1026
370-1043
530-1185
370-1034
370-1034
530-1185
530-1186
530-1249
530-1250
540-1301
300-1015
530-1199
540-1302
none
none
none
none
none
800-1292

DESCRIPTION

AC Power Cord (115V)
AC Power Cord (240V)
Adaptec ACB-4000 SCSI Disk Controller
Sysgen SC4000 SCSI Tape Controller
Archive Stand Alone Controller (SAC)
45/60MB 1/4" Tape Drive, QIC-11/24, Archive Basic 9050B
External SCSI Cable, DD-50SA to DD-50SA, 1.0M (obs)
71 MB Disk Drive, Micropolis 1325
71 MB Disk Drive, Fujitsu M2243AS
External SCSI Cable, DD-50SA to DD-50SA, 1.0M (obs)
External SCSI Cable, DD-50SA to DD-50SA, 3.0M (obs)
External SCSI Cable, DD-50SA to DD-50SA, 1.0M
External SCSI Cable, DD-50SA to DD-50SA, 3.0M
150 Watt Power Supply Assembly
• 150 Watt Power Supply
• DC Wire Harness
• AC Line Filter
DC Fan Assembly
Disk Command Cable (use 530-1157)
Disk Data Cable (use 530-1145)
Tape Command Cable (use 530-1103)
Internal SCSI Command Cable
Sun/50 Mass Storage Subsystem Service Manual

Technical Volume II

OPT-7

PARTS BREAKDOWN

12/90

60

61

62

73

65MB Disk

65MB Disk
20MB Tape

65MB Disk
Expansion

20MB Tape

Rackmountable Disk and Tape Subsystem
PART #

DESCRIPTION

140-1024 Fuse, 5A (115V)
150-0137 AC Filter/Fuse/Switch
180-1097 AC Power Cord (115V)
180-1125 AC Power Cord (240V)
300-0566 170 Watt Power Supply (obsolete)
300-1014 250 Watt Power Supply
340-1274 Mounting Bracket for 300-1014 Power Supply
370-0567 65MB SMD Disk Drive, Fujitsu M2312K
370-1011 Sysgen SC4000 SCSI Tape Controller
370-1024 20MB 1/4" Tape Drive, QIC-11, Archive Basic 9020B
370-1026 Archive Stand Alone Controller (SAC)
530-0554 DC Harness, Power Supply to Disk Drive
530-1052 AC Harness, AC Filter to Power Supply
530-1053 Power Supply &. Filter Ground Harness
530-1079 • External SMD Command Cable, 0.7M
530-1080 • External SMD Data Cable, 0.7M
530-1103 Tape Command Cable, Tape Drive to Sysgen SC4000
530-1104 DC Harness, Power Supply to Tape Subsystem
530-1115 Tape Command Cable, Archive SAC to Tape Drive
530-1153 DC Harness, DC Fan
530-1209 External SMD Command Cable, 2.0M
530-1210 External SMD Data Cable, 2.0M
540-1051 SCSI Cable Panel Assembly
530-1108 • Internal SMD Command Cable
530-1216 • Internal SCSI Command Cable
530-1219 • Internal SMD Data Cable
540-1509 DC Fan Assembly, 88 CFM

OPT-8

Field Engineer Handbook

12/90

PARTS BREAKDOWN

63

64

65

130MB Disk

130MB Disk
Expansion

130MB Disk
Expansion

Rackmountable Disk and Tape Subsystem
PART #

DESCRIPTION

140-1024
150-0137
180-1097
180-1125
300-0566
300-1014
340-1274
370-1011
370-1014
370-1024
370-1026
530-0554
530-1052
530-1053
530-1079
530-1080
530-1103
530-1104
530-1115
530-1153
530-1209
530-1210
540-1051
530-1108
530-1216
530-1219
540-1509

Fuse, 5A (115V)
AC Filter/Fuse/Switch
AC Power Cord (115V)
AC Power Cord (240V)
170 Watt Power Supply (obsolete)
250 Watt Power Supply
Mounting Bracket for 300-1014 Power Supply
Sysgen SC4000 SCSI Tape Controller
130MB SMD Disk Drive, Fujitsu M2322K
20MB 1/4" Tape Drive, QIC-11, Archive Basic 9020B
Archive Stand Alone Controller (SAC)
DC Harness, Power Supply to Disk Drive
AC Harness, AC Filter to Power Supply
Power Supply & Filter Ground Harness
• External SMD Command Cable, 0.7M
• External SMD Data Cable, 0.7M
Tape Command Cable, Tape Drive to Sysgen SC4000
DC Harness, Power Supply to Tape Subsystem
Tape Command Cable, Archive SAC to Tape Drive
DC Harness, DC Fan
External SMD Command Cable, 2.0M
External SMD Data Cable, 2.0M
SCSI Cable Panel Assembly
• Internal SMD Command Cable
• Internal SCSI Command Cable
• Internal SMD Data Cable
DC Fan Assembly, 88 CFM

Technical Volume II

OPT-9

PARTS BREAKDOWN

12/90

63

64

65

130MB Disk

130MB Disk
Expansion

2x 130MB Disks

Disk Subsystem (9-Slot Chassis)
PART #

140-1010
150-1041
150-1042
150-1018
150-1039
180~1097

180-1125
240-1020
240-1048
300-0566
300-1014
330-1009
340-1037
340~1039

340-1261
340-1262
340~1276

370-1014
530-0550
530-0554
530~1014

530-1052
530-1063
530~1064

530-1076
530-1019
530-1080
530-1100
540-1128
530-1209
530-1210
540-1509

OPT-10

DESCRIPTION

Fuse. 5A (115V)
Fuseholder
Fusecarrier
Power Switch. Illuminated
AC Line Filter
AC Power Cord (115V)
AC Power Cord (240V)
Air Filter
Castor
170 Watt Power Supply (obsolete)
250 Watt Power Supply
Front Bezel
Side Cover (obsolete)
Top Cover
Right Side Cover
Left Side Cover
Mounting Bracket for 300-1014 Power Supply
130MB SMD Disk Drive. Fujitsu M2322K
DC Harness. Power Supply Ground Connect
DC Harness. Power Supply to Disk Drive
AC Harness. Line Filter to Power Switch
AC Harness. Power Supply to Power Supply
Internal SMD Command Cable
Internal SMD Data Cable
AC Harness. Power Switch to Power Supply
External SMD Command Cable. O.IM (obsolete)
External SMD Data Cable. 0.7M (Obsolete)
DC Harness. Power Supply to Fan
DC Fan Assembly. 71 CFM
External SMD Command Cable. 2.0M
External SMD Data Cable. 2.0M
DC Fan Assembly. 88 CFM (obsolete)

Field Engineer Handbook

12/90

PARTS BREAKDOWN

66

67

0169

0169EX

130MB Disk

130MB Disk
Expansion

130MB Disk

130MB Disk
Expansion

130MB SMD Disk Subsystem
PART #

DESCRIPTION

300-1001
300-1003
370-1003
370-1004
530-0607
530-1010
530-1046
530-1047
530-1079
530-1080
530-1209
530-1210

Power Supply (115V)
Power Supply (240V)
130MB SMD Disk Drive, Fujitsu M2284K
Terminator, Fujitsu M2284K
External SMD Daisy Chain Cable, Sun-2/150U
External SMD Daisy Chain Command Cable
External SMD Command Cable, 1.0M, Sun-2/150U
External SMD Data Cable, 1.0M, Sun-2/150U
External SMD Command Cable, 0.7M (obsolete)
External SMD Data Cable, 0.7M (obsolete)
External SMD Command Cable, 2.0M
External SMD Data Cable, 2.0M

540-1042
530-1097
530-1218

SMD Cable Panel Assembly, 19" Rackmount
• SMD Command Cable
• SMD Data Cable

Technical Volume"

OPT-11

PARTS BREAKDOWN

0474 0474EX
380MB Disk

380MB Disk

Expansion

12/90

68

69

620

621

380MB Disk 380MB Disk 380MB Disk 380MB Disk
Expansion
Expansion

380MB SMD Disk Subsystem
PART

DESCRIPTION

340-1430
340-1470
370-1003
370-1004
530-0607
530-1046
530-1047
530-1079
530-1080
530-1209
530-1210
530-1214
530-1219

Top Cover
Head Lock Access Cover
380MB SMD Disk Drive, Fujitsu M2351A
Terminator, Fujitsu M2351A
External SMD Daisy Chain Cable, Sun-2/150U
External SMD Command Cable, 1.0M, Sun-2/150U
External SMD Data Cable, 1.0M, Sun-2/150U
External SMD Command Cable, 0.7M
External SMD Data Cable, 0.7M
External SMD Command Cable, 2.0M
External SMD Data Cable, 2.0M
External SMD Command Cable, 300 mm (obsolete)
External SMD Data Cable, 500 mm (obsolete)

540-1042
530-1097
530-1218

SMD Cable Panel Asembly, 19" Rackmount
• SMD Command Cable
• SMD Data Cable

540-1396
340-1431
530-1244
530-1245

Rear Cover Assembly
• Rear Cover
• SMD Command Cable
• SMD Data Cable

OPT-12

Field Engineer Handbook

12/90

PARTS BREAKDOWN

75

670

TR

1/2" Tape

1/2" Tape

1/2" Tape

1600 BPI 1/2" Tape Drive
PART #

180-1097
180-1125
370-0479
530-1043
530-1079
530-1209
540-1042
530-1098
540-1368
530-1243

DESCRIPTION

AC Power Cord (115V)
AC Power Cord (240V)
1600 BPI 1/2" Tape Orive, COC 92181
External Tape Command Cable, 1.0M
External Tape Command Cable, 0.7M, OB-25 & OB-37 (obs
External Tape Command Cable, 1.0M, OB-25 & OB-37
1/2" Tape Cable Panel Asembly, 19" Rackmount
• Tape Command Cable
1/2" Tape Cable Panel Asembly, 19" Rackmount
• Tape Command Cable

Technical Volume II

OPT-13

PARTS BREAKDOWN

78

12/90

675

6250 BPI 1/2" Tape Drive
PART #

370-1062
230-4601
530-1346
530-1348
555-1055
811-1031
811-1040
811-1048
811-1026
811-1027
811-1028
811-1029
811-1030
811-1031
811-1032
811-1033
811-1034
811-1035
230-4601
811-1036
811-1037
811-1038
811-1039
811-1040
811-1041
811-1042
811-1043
811-1044
811-1045
811-1046
811-1047

OPT-14

DESCRIPTION

6250 BPI 1/2" Tape Drive, Fujitsu M2444AC
• Elastic File Reel Hub Ring
• AC Power Cord, IEC to CPC (240V)
• AC Power Cord, NEMA 6-15P to CPC (230V)
• Adjusted Tension Sensor, Idler Tachometer, & RPA Assy
• Tension Sensor
• Idler Tachometer
• RPGMU PCA (RPA)
• Tape Panel
• Power Supply
• Fuse
• Operator Panel with Red LEOs
• BOT/EOT Sensor
• Tension Sensor
• File Reel Motor
• Write Enable Sensor
• File Reel Tachometer Sensor
• File Reel Hub
• Elastic File Reel Hub Ring
• Shield Block
• Machine Reel Motor
• Machine Tachometer Sensor
• Machine Reel
• Idler Tachometer
• Tape Loading Fan
• Tape Head
• Roller Catch
• Air Filter
• Right Fan
• Left Fan
• Red Power Switch

Field Engineer Handbook

PARTS BREAKDOWN

12/90

78

675

6250 BPI 1/2" Tape Drive - Continued
PART #

DESCRIPTION

811-1048
811-1049
811-1050
811-1051
811-1052
811-1053
811-1054
811-1055
811-1056
811-1057
811-1058
811-1149

•
•
•
•
•
•
•
•
•

530-1079
530-1209
530-1691

External Tape Command Cable, 0.7M, OB-25 & OB-37 (obs
External Tape Command Cable, 1.0M, OB-25 & OB-37
External Tape Command Cable, 5.5M, OB-25 & OB-37

540-1368
530-1243

1/2" Tape Cable Panel Assembly, 19" Rackmounted
• Tape Command Cable

540-1429
530-1299
530-1301

1/2" Tape Drive Cable Panel Assembly, Tape Drive Mounted
• Tape Command Cable A
• Tape Command Cable B

800-1409

M244X Series Streaming Tape Drive CE Manual

RPGMU PCA (RPA)
WAPMU PCA (WTA)
UIJMU PCA (SVA)
Buffer PCA (BUF)
512186U PCA (WFM)
512188U PCA (RFM)
532705U PCA (MPU)
532706U PCA (IFU)
RKEMU PCA (ROA)
550194U PCA (VFO)
• Tachometer Cup
• Operator Panel Cable

•

Technical Volume"

OPT-15

12/90

PARTS BREAKDOWN

180

SunButtons
DESCRIPTION

PART #

180-1125
260-3861
300-1053
300-1054
370-1291
530-1525

•
•
•
•
•
•

AC Power Cord (240V) (obsolete)
Overlay Template
Power Supply (115V)
Power Supply (240V)
SunButtons Box
OB-9 to OB-15 to 01N-5 Cable, 200M

190

SunDials
PART #

DESCRIPTION

595-1737
260-3257
300-1053
370-1223
530-1525
540-1935

SunDials Assembly (115V)
• Overlay Template
• Power Supply (115V)
• Oialbox & Bale
• OB-9 to OB-15 to 01N-5 Cable, 200M
• RFI Filter, OB-25

595-1773
180-1125
260-3257
300-1054
370-1223
530-1525
540-1935

SunDials Assembly (240V)
• AC Power Cord (240V) (obsolete)
• Overlay Template
• Power Supply (240V)
• Oialbox & Bale
• OB-9 to OB-15 to 01N-5 Cable, 200M
• RFI Filter, OB-25

OPT-16

Field Engineer Handbook

12/90

PARTS BREAKDOWN

501

503

511

71MB Disk

71MB Disk
Expansion

71MB Disk
60MB Tape

Mass Storage Subsystem (Sun-3 Shoebox)
140-1002
150-1034
180-1097
180-1125
300-1019
530-1238
530-1237
300-1028
530-1326
530-1325
340-1376
340-1401
370-1010
370-1034
370-1061
370-1076
370-1103
370-1103
370-1235
530-1233
530-1234
530-1235
530-1236
530-1249
530-1250
540-1333
540-1406
540-1411
540-1511
540-1512
540-1752
555-1076
300-1045
530-1432
811-9015

Fuse, 3A (240V)
Fuse, 3A (115V)
AC Power Cord (115V)
AC Power Cord (240V)
170 Watt Power Supply (obsolete)
• DC Harness, Power Supply to Peripherals (obsolete)
• AC Harness, Power Supply to Select Switch (obsolete)
170 Watt Power Supply
• DC Harness, Power Supply to Peripherals
• AC Harness, Power Supply to Voltage Select Switch
Tape Drive Mounting Bracket
Disk Drive Mounting Bracket
Adaptec ACB-4000 SCSI Disk Controller
71MB Disk Drive, Micropolis 1325 or Fujitsu M2243AS
Emulex MT02 Tape Controller
45/60MB 1/4" Tape Drive, Wangtech 5099EN24 (obsolete)
45/60MB 1/4" Tape Drive, QIC-11/24, Wangtech 5099EN24
45/60MB 1/4" Tape Drive, QIC-11/24, Archive 5945C
Emulex MT02 Tape Controller
Internal SCSI Cable
Internal SCSI Disc Data Cable
Internal SCSI Disk Command Cable
Internal SCSI Tape Command Cable
External SCSI Cable, DD-50SA to DD-50SA, 1.0M
External SCSI Cable, DD-50SA to DD-50SA, 3.0M
AC Switch Assembly (obsolete)
AC Switch Assembly
DC Fan (obsolete)
110/220 Voltage Select Switch
DC Fan Assembly, 180 mm Wire Harness
DC Fan Assembly, 65 mm Wire Harness
170 Watt to 130 Watt Power Supply Conversion Kit
• 130 Watt Power Supply
• DC Harness, Power Supply to Peripherals
• Faston Adapter Power Supply to Voltage Select Switch

Technical Volume"

OPT-17

12/90

PARTS BREAKDOWN

504

505

514

141MB Disk

141MB Disk
Expansion

141MB Disk
60MB Tape

Mass Storage Subsystem (Sun-3 Shoebox)
PART #

140-1002
150-1034
180-1097
180-1125
300-1028
530-1326
530-1325
340-1376
340-1401
370-0551
370-0551
370-0552
370-1061
370-1076
370-1103
370-1103
370-1235
370-1236
530-1233
530-1234
530-1235
530-1236
530-1249
530-1250
540-1406
540-1511
540-1512
540-1752
555-1076
300-1045
530-1432
811-9015
813-1011

OPT-18

DESCRIPTION

Fuse, 3A (240V)
Fuse, 3A (115V)
AC Power Cord (115V)
AC Power Cord (240V)
170 Watt Power Supply
• DC Harness, Power Supply to Peripherals
• AC Harness, Power Supply to Voltage Select Switch
Tape Drive Mounting Bracket
Disk Drive Mounting Bracket
141MB Disk Drive, Micropolis 1355
141MB Disk Drive, Toshiba MK156
Emulex MD21 ESDI Disk Controller
Emulex MT02 Tape Controller
45/60MB 114" Tape Drive, Wangtech 5099EN24 (obsolete)
45/60MB 114" Tape Drive, QIC-11/24, Wangtech 5099EN24
45/60MB 114" Tape Drive, QIC-11/24, Archive 5945C
Emulex MT02 Tape Controller
Emulex MD21 ESDI Disk Controller
Internal SCSI Cable
Internal SCSI Disc Data Cable
Internal SCSI Disk Command Cable
Internal SCSI Tape Command Cable
External SCSI Cable, DD-50SA to DD-50SA, 1.0M
External SCSI Cable, DD-50SA to DD-50SA, 3.0M
AC Switch Assembly
110/220 Voltage Select Switch
DC Fan, 180 mm Wire Harness
DC Fan, 65 mm Wire Harness
170 Watt to 130 Watt Power Supply Conversion Kit
• 130 Watt Power Supply
• DC Harness, Power Supply to Peripherals
• Faston Adapter Power Supply to Voltage Select Switch
Sunl3 Mass Storage Subsystem Field Service Manual

Field Engineer Handbook

12/90

PARTS BREAKDOWN

506

507

509

510

516

327MB Disk

327MB Disk
Expansion

2x 327MB Disk
Expansion

2x 327MB Disk

327MB Disk
60MB Tape

Mass Storage Subsystem (Sun-3 Shoebox)
PART #

140-1002
150-1034
180-1097
180-1125
300-1028
530-1326
530-1325
340-1720
340-1401
370-0552
370-1133
370-1061
370-1076
370-1103
370-1103
370-1235
370-1236
530-1233
530-1234
530-1235
530-1236
530-1249
530-1250
530-1406
530-1407
540-1406
540-1511
540-1512
540-1752
555-1076
300-1045
530-1432
811-9015
813-1011

DESCRIPTION

Fuse, 3A (240V)
Fuse, 3A (115V)
AC Power Cord (115V)
AC Power Cord (240V)
170 Watt Power Supply, Todd or Cal DC
• DC Harness, Power Supply to Peripherals
• AC Harness, Todd Power Supply to Voltage Select Switch
Tape Drive & 2nd Disk Drive Mounting Bracket
Disk Drive Mounting Bracket
Emulex MD21 ESDI Disk Controller
327MB Disk Drive, Micropolis 1558-15
Emulex MT02 SCSI Tape Controller
45/60MB 114" Tape Drive, Wangtech 5099EN24 (obsolete)
45/60MB 114" Tape Drive, QIC-11/24, Wangtech 5099EN24
45/60MB 114" Tape Drive, QIC-11/24, Archive 5945C
Emulex MT02 SCSI Tape Controller
Emulex MD21 ESDI Disk Controller
Internal SCSI Cable
Internal SCSI Disc Data Cable, 1st Disk Drive
Internal SCSI Disk Command Cable
Internal SCSI Tape Command Cable
External SCSI Cable, DD-50SA to DD-50SA, 1.0M
External SCSI Cable, DD-50SA to DD-50SA, 3.0M
Internal SCSI Disc Data Cable, 2nd Disk Drive
Internal SCSI Disk Command Cable, Dual Disk Drive
AC Switch Assembly
110/220 Voltage Select Switch
DC Fan, 180 mm Wire Harness
DC Fan, 65 mm Wire Harness
170 Watt to 130 Watt Power Supply Conversion Kit
• 130 Watt Power Supply, Boschert
• DC Harness, Power Supply to Peripherals
• Faston Adapter Power Supply to Voltage Select Switch
Sunl3 Mass Storaae Subsvstem Field Service Manual

Technical Volume II

OPT-19

12/90

PARTS BREAKDOWN

526

327MB Disk

527

327MB Disk
Expansion

530

2x 327MB Disks

539

327MB Disk
150MB Tape

External Storage and External Expansion Modules
PART #

DESCRIPTION

150-1556
300-1031
330-1146
330-1158
350-1006
350-1010
350-1011
350-1013
350-1117
370-1203
370-1246
530-1249
530-1250
530-1334
530-1365
530-1381
530-1409
530-1435
530-1593
530-1461
530-1618
530-1659
555-1005
330-1146
330-1158
370-1153
570-1042
814-5036

SCSI ID Select Switch
120 Watt Power Supply
Disk Drive Mounting Bracket
Disk Drive Removal Handle
Top Cover
Left Side Cover
Front Bezel
Right Side Cover
Rear Bezel
DC6150 QIC-150 1/4" Tape Cartridge
150MB Tape Drive, Full-Height. QIC-150
External SCSI Cable, DD-50SA to DD-50SA, 1.0M
External SCSI Cable, DD-50SA to DD-50SA, 3.0M
External SCSI Cable, DD-50SA to DD-50SA, 2.5M
External SCSI Cable, DD-50SA to DD-50SA, 41 cm
External Terminator
Internal SCSI Cable (obsolete)
External SCSI Cable, 50-Pin SCSI-2 to DD-50SA, 2.0M
External SCSI Cable, 50-Pin SCSI-2 to DD-50SA, 1.0M
1/4" Tape Drive SCSI Adapter Cable
Internal SCSI Cable
SCSI ID Select Switch Cable
327MB SCSI Disk Drive FRU Assembly

OPT-20

• Mounting Bracket

• Drive Removal Handle
• 327MB Disk Drive, Imprimis/CDC 77777107
Full-Height Peripheral Front Filler Panel
Replacing Components of Sun ESM and EEM Storage Units

Field Engineer Handbook

12/90

PARTS BREAKDOWN

This page intentionally left blank.

Technical Volume II

OPT-21

12/90

PARTS BREAKDOWN

550

552

104MB Disk

207MB Disk

Desktop Disk Pack

TO REMOVE COVER

• Locate the holes indicate(
by X on both sides of the
cover .
• Insert a small screwdriver
into one of the holes to
depress the catch and
release the cover.

4

2

12

OPT-22

Field Engineer Handbook

12/90

PARTS BREAKDOWN

550

552

104MB Disk

207MB Disk

Desktop Disk Pack
CODE

PART #

1
2
3
4
NS
2
3
4
NS
5
6
7
8
8
9
9
10
11
12
NS
NS
NS
NS
NS
NS
NS

540-1777
540-1776
150-1338
540-1802
150-1174
540-1978
150-1557
540-1802
150-1174
540-1773
330-1214
300-1037
540-1774
540-2049
370-1200
370-1376
340-1966
530-1454
530-1522
240-1141
150-1346
530-1434
530-1435
530-1508
530-1593
800-4895

DESCRIPTION

Disk Drive Cover Assembly
Fan/SCSI Connector/Unit Select Assembly (obsolete)
Unit Select Switch (obsolete)
Fan Assembly
2A Subminiature Fuse
Fan/SCSI Connector/Unit Select Assembly
Unit Select Switch
Fan Assembly
2A Subminiature Fuse
Base Assembly
Rubber Foot
Power Supply Assembly
104MB Disk Drive Assembly
207MB Disk Drive Assembly
104MB Disk Drive, Quantum 105S
207MB Disk Drive, Quantum 210S
Disk Drive Bracket
Unit Select Switch Cable
Power Indicator LED Cable
Screw, #6-32 x 1/4"
External SCSI Bus Terminator
External Cable, 50-Pin SCSI-2 to 50-Pin SCSI-2, 0.45 m
External Cable, 50-Pin SCSI-2 to DD-50SA, 2.0 m
External Cable, 50-Pin SCSI-2 to 50-Pin SCSI-2, 0.8 m
External Cable, 50-Pin SCSI-2 to DD-50SA, 1.0 m
Desktop Storage Pack Field Service Manual

•
•
•
•
•
•
•

•
•
•
•
•

•

Technical Volume II

OPT-23

12/90

PARTS BREAKDOWN

558
Desktop SunCD Pack

TO REMOVE COVER
• Locate the holes indicated
by X on both sides of the
cover .

• Insert a small screwdriver
into one of the holes to
depress the catch and
release the cover.

4

2

6

9

11

8

OPT-24

10

Field Engineer Handbook

PARTS BREAKDOWN

12/90

558
Desktop SunCD Pack
CODE

PART #

1
2
3
4
NS
5
6
7
8
9
10
11
NS
NS
NS
NS
NS
NS
NS

540-1778
540-1978
150-1557
540-1802
150-1174
540-1773
330-1214
300-1037
540-1931
370-1312
340-1967
530-1454
240-1141
150-1346
530-1434
530-1435
530-1508
530-1593
800-4895

DESCRIPTION

Cover Assembly. Tape & CD-ROM
Fan/SCSI Connector/Unit Select FRU Assembly
Unit Select Switch
Fan Assembly
2A Subminiature Fuse
Base Assembly
Rubber Foot
Power Supply Assembly
SunCD CD-ROM Assembly
Sony CDU-8012 644MB CD-ROM
Drive Bracket
Unit Select Switch Cable
Screw. #6-32 x 1/4"
External SCSI Bus Terminator
External Cable. 50-Pin SCSI-2 to 50-Pin SCSI-2. 0.45 m
External Cable. 50-Pin SCSI-2 to DD-50SA. 2.0 m
External Cable. 50-Pin SCSI-2 to 50-Pin SCSI-2. 0.8 m
External Cable. 50-Pin SCSI-2 to DD-50SA. 1.0 m
Desktop Storage Pack Field Service Manual

•
•
•
•
•
•
•

•

Technical Volume II

OPT-25

12/90

PARTS BREAKDOWN

561
669MB Disk

563

565

566

2x 669MB Disks

669MB Disk
150MB Tape

669MB Disk
2.3GB Tape

External Storage and External Expansion Module
PART #

150-1556
300-1031
330-1146
330-1158
340-2359
340-2360
350-1006
350-1010
350-1011
350-1013
350-1117
370-1203
370-1246
370-1297
370-1298
370-1318
370-1319
370-1319
370-1326
370-1326
530-1249
530-1250
530-1334
530-1365
530-1381
530-1435
530-1593
530-1461
530-1618
530-1659
570-1042
814-5036
1

DESCRIPTION

SCSI 10 Select Switch
120 Watt Power Supply
Disk Drive Mounting Bracket
Disk Drive Removal Handle
Disk Drive Mounting Bracket. Right
Disk Drive Mounting Bracket. Left
Top Cover
Left Side Cover
Front Bezel
Right Side Cover
Rear Bezel
DC6150 QIC-150 1/4" Tape Cartridge
150MB Tape Drive. Full-Height. QIC-150
2.3GB 8 mm Tape Drive. Full-height
8 mm Tape Cartridge
8 mm Cleaning Cartridge
669MB Disk Drive. Micropolis 1588-15 with Bezel
669MB Disk Drive. Maxtor XT-8760S with Bezel 1
669MB Disk Drive. Micropolis 1588-15 without Bezel
669MB Disk Drive. Maxtor XT-8760S without Bezel 1
External SCSI Cable. DD-50SA to DD-50SA. 1.0M
External SCSI Cable. DD-50SA to DD-50SA. 3.0M
External SCSI Cable. DD-50SA to DD-50SA, 2.5M
External SCSI Cable. DD-50SA to DD-50SA, 41 cm
External Terminator
External SCSI Cable. 50-Pin SCSI-2 to DD-50SA. 2.0M
External SCSI Cable. 50-Pin SCSI-2 to DD-50SA. 1.0M
1/4" Tape Drive SCSI Adapter Cable
Internal SCSI Cable
SCSI 10 Select Switch Cable
Full-Height Peripheral Front Filler Panel
Replacing Components of Sun ESM and EEM Storage Units

The Maxtor dnve does not fit into the lower dnve pOSition of External
Storage Modules manufactured prior to October 1990. Remove the
vertical stop block with 10-lnch End Cutter. 250-1074-01.

OPT-26

Field Engineer Handbook

12/90

PARTS BREAKDOWN

601
130MB Disk

602

603

130MB Disk
Expansion

2x 130MB Disks

Mass Storage Pedestal
PART #

DESCRIPTION

140-1010
140-1029
150-1041
150-1042
150-1051
150-1042
150-1018
150-1129
150-1216
180-1097
180-1125
240-1048
300-1014
330-1066
340-1138
340-1261
340-1262
340-1535
370-1014
370-1020
540-1252
540-1510
540-1561

Fuse, 5A (115V)
Fuse, 5A (240V)
Fuseholder (115V)
Fusecarrier (115V)
Fuseholder (240V)
Fusecarrier (115V)
Power Switch, Illuminated (obsolete)
AC Line Filter
Power Switch, Non-Illuminated
AC Power Cord (115V)
AC Power Cord (240V)
Castor
250 Watt Power Supply
Front Bezel
Top Cover
Right Side Cover
Left Side Cover
Disk Drive Mounting Cradle
130MB SMD Disk Drive, Fujitsu M2322K
DC Fan, 71 CFM, without Fastons (obsolete)
DC Fan Assembly, 71 CFM, Upper Chassis (obsolete)
DC Fan Assembly, 71 CFM, Upper Chassis
DC Fan Assembly, 71 CFM, Rear Panel

Technical Volume II

OPT-27

PARTS BREAKDOWN

12/90

601

602

603

130MB Disk

130MB Disk
Expansion

2x 130MB Disks

Mass Storage Pedestal - Continued
PART #

DESCRIPTION

530-1079
530-1080
530-1188
530-1189
530-1190
530-1191
530-1192
530-1193
530-1194
530-1195
530-1209
530-1210
530-1211
530-1212
530-1230
530-1231
530-1232
530-1316
530-1317
530-1404

External SMD Command Cable, 0.7M (obsolete)
External SMD Data Cable, 0.7M (obsolete)
DC Harness, Power Supply to 530-1189
DC Harness, Disk Drive to 530-1188
Internal SMD Command Cable 1
DC Harness, Lower DC Fans (obsolete)
AC Harness, Lower'Chassis (obsolete, use 530-1404)
DC Harness, Upper DC Fans (obsolete)
AC Harness, Upper Chassis (obsolete, use 530-1404)
AC Harness, Power Supply to Power Supply
External SMD Command Cable, 2.0M
External SMD Data Cable, 2.0M
Internal SMD Data Cable, Drive 1
Internal SMD Data Cable, Drive 0
AC Receptacle Assembly
AC Harness, AC Receptacle to Line Filter
Front Door Grounding Strap
DC Harness, Lower DC Fans
DC Harness, Upper DC Fans
AC Harness, Filter to Fuse to Switch to Power Supply

1

Internal SMD Command Cable part numbers 530-1190-01 and
530-1190-02 cause signal reflections. Use 530-1190-03. Install
filler panel 340-1602 in the unused 25-pin SMD Out connector.
Install filler panel 340-2044 in the unused 37-pin SMD Out connector.
Secure the filler panels with #4-40 x 3/8" Screw, 240-1292. Terminate
Drive 0, the lower drive in the pedestal.

OPT-28

Field Engineer Handbook

12/90

PARTS BREAKDOWN

605

606

280MB Disk

2x 280MB Disks

Mass Storage Pedestal
PART #

140-1010
140-1029
150-1041
150-1042
150-1051
150-1042
150-1018
150-1129
150-1216
150-1258
180-1097
180-1125
240-1048
300-1014
330-1066
340-1138
340-1261
340-1262
540-1510
540-1561
540-1635
340-1535
370-1068
370-1068
580-1169

DESCRIPTION

Fuse, 5A (115V) (obsolete, underrated)
Fuse, 5A (240V)
Fuseholder (115V)
Fusecarrier (115V)
Fuseholder (240V)
Fusecarrier (115V)
Power Switch, Illuminated (obsolete)
AC Line Filter
Power Switch, Non-Illuminated
Fuse, 7A (115V)
AC Power Cord (115V)
AC Power Cord (240V)
Castor
250 Watt Power Supply
Front Bezel
Top Cover
Right Side Cover
Left Side Cover
DC Fan Assembly, 71 CFM, Upper Chassis
DC Fan Assembly, 71 CFM, Rear Panel
280MB SMD Disk Drive FRU Assembly
•
•
•
•

Disk Drive Mounting Cradle
280MB SMD Disk Drive, Fujitsu M2333K
280MB SMD Disk Drive, CDC 9720-368, PA8A2
280MB Disk Drive FRU Packaging

Technical Volume II

OPT-29

PARTS BREAKDOWN

12/90

605

606

280MB Disk

2x 280MB Disks

Mass Storage Pedestal - Continued
PART #

DESCRIPTION

530-1079
530-1080
530-1188
530-1189
530-1190
530-1191
530-1192
530-1193
530-1194
530-1195
530-1209
530-1210
530-1211
530-1212
530-1230
530-1231
530-1232
530-1316
530-1317
530-1404

External SMD Command Cable, 0.7M (obsolete)
External SMD Data Cable, 0.7M (obsolete)
DC Harness, Power Supply to 530-1189
DC Harness, Disk Drive to 530-1188
Internal SMD Command Cable 1
DC Harness, Lower DC Fans (obsolete)
AC Harness, Lower Chassis (obsolete, use 530-1404)
DC Harness, Upper DC Fans (obsolete)
AC Harness, Upper Chassis (obsolete, use 530-1404)
AC Harness, Power Supply to Power Supply
External SMD Command Cable, 2.0M
External SMD Data Cable, 2.0M
Internal SMD Data Cable, Drive 1
Internal SMD Data Cable, Drive 0
AC Receptacle Assembly
AC Harness, AC Receptacle to Line Filter
Front Door Grounding Strap
DC Harness, Lower DC Fans
DC Harness, Upper DC Fans
AC Harness, Filter to Fuse to Switch to Power Supply

1

Internal SMD Command Cable part numbers 530-1190-01 and
530-1190-02 cause Signal reflections. Use 530-1190-03. Install
filler panel 340-1602 in the unused 25-pin SMD Out connector.
Install filler panel 340-2044 in the unused 37-pin SMD Out connector.
Secure the filler panels with #4-40 x 3/8" Screw, 240-1292. Terminate
Drive 0, the lower drive in the pedestal.

OPT-30

Field Engineer Handbook

12/90

PARTS BREAKDOWN

615

616

688MB Disk

2x 688MB Disks

Mass Storage Pedestal
PART #

140-1010
140-1029
150-1041
150-1042
150-1051
150-1042
150-1129
150-1216
150-1258
180-1097
180-1125
240-1048
300-1014
330-1066
340-1138
340-1261
340-1262
540-1510
540-1561
540-1635
240-1207
240-1356
240-1372
340-1535
370-1197
370-1300
370-1197
580-1169

DESCRIPTION

Fuse, 5A (115V) (obsolete, underrated)
Fuse, 5A (240V)
Fuseholder (115V)
Fusecarrier (115V)
Fuseholder (240V)
Fusecarrier (115V)
AC Line Filter
Power Switch, Non-Illuminated
Fuse, 7A (115V)
AC Power Cord (115V)
AC Power Cord (240V)
Castor
250 Watt Power Supply
Front Bezel
Top Cover
Right Side Cover
Left Side Cover
DC Fan Assembly, 71 CFM, Upper Chassis
DC Fan Assembly, 71 CFM, Rear Panel
688MB SMD Disk Drive FRU Assembly
• SAE #10-32 x 1/2" Screw, CDC 9720-850
• M4-0.7 x 16 mm Screw, Fujitsu M2372K (obs, too long)
• M4-0.7 x 10 mm Screw, Fujitsu M2372K
• Disk Drive Mounting Cradle
• 688MB SMD Disk Drive, Fujitsu M2372K
• Rubber Noise Insulator, Fujitsu M2372K
• 688MB SMD Disk Drive, CDC 9720-850, PA8K2
• 688MB Disk Drive FRU Packaging

Technical Volume II

OPT-31

12/90

PARTS BREAKDOWN

615

616

688MB Disk

2x 688MB Disks

Mass Storage Pedestal - Continued
PART #

530-1188
530-1189
530-1190
530-1195
530-1211
530-1212
530-1230
530-1231
530-1232
530-1316
530-1317
530-1330
530-1331
530-1404
1

DESCRIPTION

DC Harness, Power Supply to 530-1189
DC Harness, Disk Drive to 530-1188
Internal SMD Command Cable 1
AC Harness, Power Supply to Power Supply
Internal SMD Data Cable, Drive 1
Internal SMD Data Cable, Drive 0
AC Receptacle Assembly
AC Wire Harness, AC Receptacle to Line Filter
Front Door Grounding Strap
DC Harness, Lower DC Fans
DC Harness, Upper DC Fans
External SMD Command Cable, 2.0M
External SMD Data Cable, 2.0M
AC Harness, Filter to Fuse to Switch to Power Supply

Internal SMD Command Cable part numbers 530-1190-01 and
530-1190-02 cause signal reflections. Use 530-1190-03. Install
filler panel 340-1602 in the unused 25-pin SMD Out connector.
Install filler panel 340-2044 in the unused 37 -pin SMD Out connector.
Secure the filler panels with #4-40 x 3/8" Screw, 240-1292. Terminate
Drive 0, the lower drive in the pedestal.

OPT-32

Field Engineer Handbook

PARTS BREAKDOWN

12/90

625

626

575MB Disk

575MB Disk
Expansion

575MB SMD Disk Subsystem
PART #

370-1069
530-1079
530-1080
530-1209
530-1210
530-1330
530-1331
530-1692
530-1693
530-1347
530-1349
540-1424
340-1486
530-1291
530-1292
811-2004
811-2005
811-2006
811-2007
811-2008
811-2009
811-2010
811-2011
811-2012
811-2013
811-2015
811-2016
811-2017
811-2018
811-2019
811-2020
811-2021
811-2022
800-1423

DESCRIPTION

575MB SMD Disk Drive, Fujitsu M2361A
SMD Command Cable, 0.7M, Xylogics 451
SMD Data Cable, 0.7M, Xylogics 451
SMD Command Cable, 2.0M, Xylogics 451
SMD Data Cable, 2.0M, Xylogics 451
SMD Command Cable, 2.0M, Xylogics 7053
SMD Data Cable, 2.0M, Xylogics 7053
SMD Data Cable, 6.0M, Xylogics 7053
SMD Command Cable, 6.0M, Xylogics 7053
Power Cord, IEC Plug to Ring Lugs (240V)
Power Cord, NEMA 6-15P to Ring Lugs (230V)
Rear Cover Assembly
• Rear Cover
• SMD Command Cable
• SMD Data Cable
DC Power Supply (B14L-5105-0182A)
Slide Rails (B03B-4825-D020A)
Blower Assembly (C90L-1370-0900)
Air Filter (B90L-1570-0001A)
Fan Sensor (B90L-1350-0001)
Operator Panel Assembly (N860-3346-T001)
Power Amplifier PCB (B17B-0250-0010A)
Display Panel (B17B-0270-0010A)
Logic PCB (C16B-5327-0290)
Read Amplifier PCB (C16B-5502-0040)
Interface PCB, Single Channel (C17B-0230-0010A)
Back Panel (B03B-4825-E010A)
Fan (B03B-4835-D030A)
Terminator, Fujitsu M2361A (B03L-4790-0003A)
A Cable (B660-1954-T904A)
B Cable (8660-1954-T903A)
PCB Extraction Tool (C960-0300-T001)
HDA & Servo Assembly (B030A-4825-T001 A & C16B-5502-0050)
M2361A Mini-Disk Drive Customer Engineering Manual

Technical Volume II

OPT-33

PARTS BREAKDOWN

12/90

629

630

631

1 Drive

Expansion Drive

2 Drives

892MB SMD Disk Subsystem
PART #

DESCRIPTION

340-1628
340-1682
340-1689
340-1728
530-1356
530-1378
530-1379

Disk Drive Mounting Tray (obsolete)
Support Bracket, Right
Support Bracket. Left
Disk Drive Mounting Tray
External SMD Daisy Chain Command Cable
External SMD Command Cable, Xylogics 451
External SMD Data Cable, Xylogics 451

555-1008
180-1097
240-1655
240-1666
340-1683
340-1712
340-1721
370-1140
370-1141
370-1141
370-1141
370-1162
370-1163
530-1343
530-1351
540-1637
540-1638
580-1179
813-1036
813-2046

892MB Disk Drive Assembly
• AC Power Cord (115V)
• SAE #10-32 x 5/16" Screw (x3)
• SAE #8-32 x 5/16" Screw (x16)
• Slide Rail, NEC D2363
• Stop Bracket. Hitachi DK815-10 & DK815-10A
• Slide Rail, Hitachi DK815-10 & DK815-10A
• 892MB Disk Drive, NEC D2363
• 892MB Disk Drive, NEC D2363
• 892MB Disk Drive, Hitachi DK815-10
• 892MB Disk Drive, Hitachi DK815-10A
• Terminator, Hitachi DK815-10 & DK815-10A
• Terminator, NEC D2363
• AC Power Cord (240V)
• AC Power Cord (230V)
• Mounting Hardware Kit, NEC D2363
• Mounting Hardware Kit, Hitachi DK815-10 & DK815-10A
• 892MB Disk Drive Packaging
• 892MB Disk Drive Installation Manual
• 892MB Disk Drive Configuration Manual

OPT-34

Field Engineer Handbook

PARTS BREAKDOWN

12/90

641

642

643

1 Drive

2 Drives

3 Drives

644

4 Drives

645

646

Exp Drive
without Tray

Exp Drive
with Tray

892MB SMD Disk Subsystem
PART #

DESCRIPTION

340-1628
340-1728
340-1682
340-1689
530-1475
530-1476
530-1354
530-1355
530-1356

Disk Drive Mounting Tray (obsolete)
Disk Drive Mounting Tray
Support Bracket, Right
Support Bracket, Left
SMD Data Cable, 6.0M, Xylogics 7053
SMD Command Cable, 6.0M, Xylogics 7053
SMD Command Cable, 2.5M, Xylogics 7053
SMD Data Cable, 2.5M, Xylogics 7053
SMD Daisy Chain Command Cable, 2.5M

555-1008
180-1097
240-1655
240-1666
340-1683
340-1712
340-1721
370-1140
370-1141
370-1141
370-1141
370-1162
370-1163
530-1343
530-1351
540-1637
540-1638
580-1179
813-1036
813-2046

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

892MB Disk Drive Assembly
AC Power Cord (115V)
SAE #10-32 x 5/16" Screw (x3)
SAE #8-32 x 5/16" Screw (x16)
Slide Rail, NEC D2363
Stop Bracket, Hitachi DK815-10 & DK815-10A
Slide Rail, Hitachi DK815-10 & DK815-10A
892MB Disk Drive, NEC D2363
892MB Disk Drive, NEC D2363
892MB Disk Drive, Hitachi DK815-10
892MB Disk Drive, Hitachi DK815-10A
Terminator, Hitachi DK815-10 & DK815-10A
Terminator, NEC D2363
AC Power Cord (240V)
AC Power Cord (230V)
Mounting Hardware Kit, NEC D2363
Mounting Hardware Kit, Hitachi DK815-10 & DK815-10A
892MB Disk Drive Packaging
892MB Disk Drive Installation Manual
892MB Disk Drive Configuration Manual

Technical Volume II

OPT-35

12/90

PARTS BREAKDOWN

660
Desktop Backup Pack

TO REMOVE COVER
• Locate the holes indicated
by X on both sides of the
cover .

• Insert a small screwdriver
into one of the holes to
depress the catch and
release the cover.

4

2

6

11

8

OPT-36

10

Field Engineer Handbook

12/90

PARTS BREAKDOWN

660
Desktop Backup Pack
CODE

PART #

1
2
3
4
NS
2
3
4
NS
5
6
7
8
9
10
11
NS
NS
NS
NS
NS
NS
NS

540-1778
540-1776
150-1338
540-1802
150-1174
540-1978
150-1557
540-1802
150-1174
540-1773
330-1214
300-1037
540-1775
370-1218
340-1967
530-1454
240-1141
150-1346
530-1434
530-1435
530-1508
530-1593
800-4895

DESCRIPTION

Tape Drive Cover Assembly
Fan/SCSI Connector/Unit Select Assembly (obsolete)
Unit Select Switch (obsolete)
Fan Assembly
2A Subminiature Fuse
Fan/SCSI Connector/Unit Select Assembly
Unit Select Switch
Fan Assembly
2A Subminiature Fuse
Base Assembly
Rubber Foot
Power Supply Assembly
1/4" Tape Drive Assembly
150MB Tape Drive, QIC-150, Archive 2150S
Tape Drive Bracket
Unit Select Switch Cable
Screw, #6-32 x 1/4"
External SCSI Bus Terminator
External Cable, 50-Pin SGSI-2 to 50-Pin SCSI-2, 0.45 m
External Cable, 50-Pin SCSI-2 to DD-50SA, 2.0 m
External Cable, 50-Pin SCSI-2 to 50-Pin SCSI-2, 0.8 m
External Cable, 50-Pin SCSI-2 to DD-50SA, 1.0 m
Desktop Storage Pack Field Service Manual

•
•
•
•
•
•
•
•

•
•
•

Technical Volume II

OPT-37

12/90

PARTS BREAKDOWN

This page intentionally left blank.

OPT-38

Field Engineer Handbook

12/90

680
Tabletop

PARTS BREAKDOWN

682

683

684

56" Rack

56" Expansion Rack
1st Drive

56" Expansion Rack
2nd Drive

Front-Load 1/2" Tape Drive
PART #

150-1407
180-1097
180-1190
230-1166
230-1177
240-1207
250-1018
330-1312
340-1868
340-2185
340-2220
340-2288
340-2289
370-1254
530-1501
530-1502
530-1503
530-1568
540-1821
540-1823
800-3447

DESCRIPTION

SCSI Terminator, Centronics
115V Power Cord
240V Power Cord
Tie Wrap, 5.5"
Cable Tie Clip
10-32 x 1/2" Screw
Rubber Stop Bumper
Shipping Bracket. 56" Rack (obsolete)
Shipping Bracket, 56" Rack (obsolete)
Shipping Bracket. 56" Rack (obsolete)
Shipping Bracket, 56" Rack (obsolete)
Shipping Bracket, Outer Side, 56" Rack
Shipping Bracket, Inner Side, 56" Rack
Outer Slide Rails
Data Cable, 2.0M, DD-50SA to Centronics
Data Cable, 1.5M, Centronics to Centronics
Data Cable, 2.0M, 50-Pin SCSI-2 to Centronics
Data Cable, 4.0M, DD-50SA to Centronics
Tabletop Tape Drive Assy
Rackmounted Tape Drive Assy
Sun Front-Load 112-lnch Tape Drive Field Service Manual

Technical Volume II

OPT-39

PARTS BREAKDOWN

680

682

Tabletop

56" Rack

12/90

683

684

56" Expansion Rack
1st Drive

56" Expansion Rack
2nd Drive

Front-Load 1/2" Tape Drive

22

\S)
r

21

6

24

OPT-40

Field Engineer Handbook

PARTS BREAKDOWN

12/90

680

682

683

684

Tabletop

56" Rack

56" Expansion Rack
1st Drive

56" Expansion Rack
2nd Drive

Front-Load 1/2" Tape Drive
CODE

SUN PART#

HP PART#

1
2
3
4
5
6
7
8
9
9
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

811-1236
811-1210
811-1227
811-1228
811-1242
811-1245
811-1241
811-1229
140-1011
140-1002
140-1039
811-1235
811-1231
811-1215
811-1218
811-1214
811-1216
811-1209
811-1233
811-1219
370-1276
370-1277
370-1279
811-1232
811-1211
811-1212

88780-67707
07980-44111
07980-61616
07980-65000
07980-69025
07980-60043
88780-69015
07980-67919

3110-0178
1390-0776
07980-60041
07980-60052
07980-60040
07980-60045
07980-21701
1460-2180
07980-60053
07980-66531
07980-66503
07980-66514
1420-0314
07980-60000
07980-60008

Technical Volume II

DESCRIPTION

Front Bezel Assembly
Power Switch Button
Power Switch Assembly
Door Latch Assembly
Power/Motor Drive Board
Fan
Single Ended I/O Board
Power Module
6.0A Fuse, .25x1.25" (115V)
3.15A Fuse, 5x20mm (240V)
3.0A Fuse, .25x1.25" (230V)
Cover Hinge
Cover Latch
Speed Sensor Assembly
Takeup Hub Assembly
EOT/BOT Sensor Assembly
Arm Buffer Assembly
Buffer Arm Bearing (Roller Guide)
Buffer Spring
Supply Hub Assembly
Read/Write/Format Board
Drive Controller Board
Data Buffer Board
3V Lithium Battery
Mother Board PCA
Display (Front Panel PCA)

OPT-41

PARTS BREAKDOWN

12/90

680

682

683

684

Tabletop

56" Rack

56" Expansion Rack
1st Drive

56" Expansion Rack
2nd Drive

Front-Load 1/2"Tape Drive

29
28

27

~

26

C>

OPT-42

~
30

d:!f?

Field Engineer Handbook

PARTS BREAKDOWN

12/90

680

682

683

684

Tabletop

56" Rack

56" Expansion Rack
1st Drive

56" Expansion Rack
2nd Drive

Front-Load 1/2" Tape Drive
CODE

SUN PART#

HP PART#

25
26
27
28
29
30
31
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

811-1230
811-1217
811-1226
811-1238
811-1237
811-1213
811-1292
811-1220
811-1221
811-1222
811-1223
811-1224
811-1225
811-1234
811-1240
811-1243
811-1244

07980-86500
07980-60050
07980-60144
07980-60042
07980-60051
07980-60009
9100-4637
07980-60062
07980-60064
07980-60067
07980-60070
07980-60071
07980-60072
3101-2923
07980-60065
88780-60290
07980-60048

Technical Volume II

DESCRIPTION

Blower Motor
Takeup/Supply Reel Motor
Hub Lock Assembly
Head Plate Assembly
Tape Displacement Unit
Tape Sensor Assembly
Transformer
Speed Sensor Cable
Front Panel Cable
Interface Cable
Cable Harness
Read Head Cable
Write Head Cable
Door Microswitch
Motor Control Cable
Firmware Kit
NR21 Speed Sensor

OPT-43

12/90

PARTS BREAKDOWN

707A

706A
1 Disk

2 Disks

1 Tray

709A

710A

4 Disks
1 ISP-80

8 Disks
1 ISP-80

2 Trays

4 Trays

1.2GB IPI-2 Disk Subsystem

5

OPT-44

Field Engineer Handbook

PARTS BREAKDOWN

12/90

706A

707A

709A

710A

11.2GB Disk

2 1.2GB Disks

4 Disks

8 Disks

1.2GB IPI-2 Disk Subsystem
CODE

PART #

DESCRIPTION

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

540-1770
300-1041
370-1263
240-1603
240-1185
370-1262
240-1035
240-1602
370-1350
370-1187
240-1185
250-1013
240-1186
240-1595
180-1185
250-1023
340-1854
240-1185
250-1016
330-1224
330-1226
370-1221
330-1225
240-1601
240-1596
180-1183
180-1184
340-1853
340-1855
340-1856
340-1891
340-2296
370-1220
530-1351
530-1343
530-1487
530-1488
530-1518
530-1536
None
370-1330

IPI Drive. Power Supply. & Tray Assembly
205W Power Supply
DC Harness
Cable Clamp
Screw. #6-32 x 1/4"
Operator Panel Harness
Lock Washer. #6
Cable Clamp
Air Baffle
1.2GB Disk. Seagate 97209-12G. PA8R2
#6-32 x 1/4" Screw (use 7/64" Hex Screwdriver)
Ground Strap
#6-32 x 3/8" Screw
Power Cord Clamp
AC Power Cord. 572 mm
Ground Strap
Tray
#6-32 x 1/4" Screw (use 7/64" Hex Screwdriver)
Filter
Operator Panel Mounting Bracket
Operator Panel Shield
Operator Panel
Operator Panel Cover
#6-32 x 1/4"Screw (use 2 mm Hex Screwdriver)
#6-32 x 7/8" Screw (use 7/64" Hex Screwdriver)
AC Power Cord. 'Y' (230V)
AC Power Cord. 'Y' (240V)
Dual Drive Tray (obsolete)
Tray Slide. Right (obsolete)
Tray Slide. Left (obsolete)
Tray Spacer
Dual Drive Tray
IPI Drive Terminator
AC Power Cord (230V)
AC Power Cord (240V)
IPI Drive 1/0 Cable. 8.0M
IPI Drive 1/0 Cable. 1.0M
IPI Drive 1/0 Cable. 2.0M
IPI Drive 1/0 Cable. 450 mm
#6-32 x 1/4"Screw (use T15 Torx Screwdriver)
Connector Assembly (use 7/64" Hex Screwdriver)

Technical Volume"

OPT-45

PARTS BREAKDOWN

716A

12/90

717A

1 Disk

2 Disks
1 Tray

719A

720A

4 Disks
1 ISP-80
2 Trays

8 Disks
1 ISP-80
4 Trays

911MB IPI-2 Disk Subsystem

5

9

4

12

~ 'th~~

~ ~\

"~~

IJ

\

\

16

15

18

"

21
22

OPT-46

Field Eng.ineer Handbook

12/90

PARTS BREAKDOWN

716A

717A

719A

720A

1 Disk

2 Disks

4 Disks

8 Disks

911 MB IPI-2 Disk Subsystem
CODE

PART #

DESCRIPTION

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

540-2005
300-1074
370-1263
240-1603
240-1185
370-1262
240-1035
240-1602
370-1350
370-1351
240-1185
250-1013
240-1186
240-1595
180-1185
250-1023
340-1854
240-1185
250-1016
330-1224
330-1226
370-1355
330-1225
240-1601
240-1596
180-1183
180-1184
340-1853
340-1855
340-1856
340-1891
340-2296
370-1220
530-1351
530-1343
530-1487
530-1488
530-1518
530-1536
None
370-1330

IPI Drive, Power Supply, & Tray Assembly
215 Watt Power Supply
DC Harness
Cable Clamp
Screw, #6-32 x 1/4"
Operator Panel Harness
Lock Washer, #6
Cable Clamp
Air Baffle
911 MB Disk, Seagate 97229-11 G, PA8Y2
#6-32 x 1/4" Screw (use 7/64" Hex Screwdriver)
Ground Strap
#6-32 x 3/8" Screw
Power Cord Clamp
AC Power Cord, 572 mm
Ground Strap
Tray
#6-32 x 1/4" Screw (use 7/64" Hex Screwdriver)
Filter
Operator Panel Mounting Bracket
Operator Panel Shield
Operator Panel
Operator Panel Cover
#6-32 x 1/4"Screw (use 2 mm Hex Screwdriver)
#6-32 x 7/8" Screw (use 7/64" Hex Screwdriver)
AC Power Cord, 'Y' (230V)
AC Power Cord, 'Y' (240V)
Dual Drive Tray (obsolete)
Tray Slide, Right (obsolete)
Tray Slide, Left (obsolete)
Tray Spacer
Dual Drive Tray
IPI-2 Disk Terminator
AC Power Cord (230V)
AC Power Cord (240V)
IPI Drive I/O Cable, 8.0M
IPI Drive I/O Cable, 1.0M
IPI Drive I/O Cable, 2.0M
IPI Drive I/O Cable, 450 mm
#6-32 x 1/4"Screw (use T15 Torx Screwdriver)
Connector Assembly (use 7/64" Hex Screwdriver)

Technical Volume II

OPT-47

PARTS BREAKDOWN

731

688MB Disk

732

2688MB Disks

12/90

733

3688MB Disks

734

4688MB Disks

Sun Expansion Pedestal
CODE

PART #

NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
1
1
1
2
3
NS
NS
NS
NS
NS
NS
4
5
6
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS

330-1192
340-1898
370-1275
530-1330
530-1530
530-1497
540-1731
540-1749
540-1846
540-1847
540-1849
540-1939
540-1921
540-1812
540-1814
530-1533
530-1532
240-1571
240-1394
340-1938
340-2109
340-2186
240-1559
230-1188
530-1589
540-1813
370-1292
340-1985
340-2300
240-1373
530-1546
240-2356
340-2180
230-1062
240-1559
540-1915
340-1580
530-1589
240-1344

OPT-48

DESCRIPTION

Disk Bezel Insert
Top Cover
External Terminator
External SMD Data Cable, 2.0M
External SMD Command Cable, 2.0M
External SMD Daisy Chain Cable, 400 mm
Front Panel Assembly (obsolete)
Rear Bumper Assembly
Side Panel Assembly
Rear Bezel Assembly
Front Bumper Assembly (obsolete)
Front Panel and Bumper Assembly
2-Drive Rear I/O Panel Assembly with Cables
4-Drive Rear I/O Panel Assembly with Cables
Rear Panel without Cables
• Internal Data Cable, 1.2
• Internal Command Cable, 960 mm
• Screw Female Standoff
• Screw, M3 x 8 mm
• Data Port Filler Panel
• Command Port Filler Panel
Air Duct Filler Panel
Screw, M4 0.7 x 6 mm
• 6" Cable Tie
Ground Strap
Disk Drive FRU Assembly
• 688MB Disk Drive, Fujitsu M2372K
• Disk Mounting Cradle (obsolete)
Disk Mounting Cradle
Kepnut, M4
• DC Harness Fujitsu
• Screw, M4 0.7 x 16 mm
• Fan Duct, Fujitsu M2372
• Grommet
Screw, M4 0.7 x 6 mm
Fan Assembly
• Fingerguard
• Ground Strap
• Screw, #6-32 x 1 1/2"

•

•
•
•
•
•

Field Engineer Handbook

PARTS BREAKDOWN

12/90

731

1688MB Drive

732

2688MB Drives

733

3688MB Drives

734

4688MB Drive

Sun Expansion Pedestal

2-----tt-HV.~~

8

DATA CABLES

3 ----+HfI--f"'--:
COMMAND CABLES

4

Field Engineer Handbook - Technical Volume II

OPT-49

PARTS BREAKDOWN

12/90

731

688MB Disk

732

2688MB Disks

733

3688MB Disks

734

4688MB Disks

Sun Expansion Pedestal - Continued
CODE

PART #

6
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
7
NS
NS
8
NS
NS
9
10
11
12
12
NS
NS
NS
NS
NS

540-1813
370-1292
340-1985
340-2300
240-1207
240-1373
530-1544
340-2178
240-1308
240-1432
540-1915
340-1580
240-1344
240-1036
240-1202
540-1765
340-2050
501-1531
540-1748
340-1936
330-1213
530-1495
340-2129
240-1372
300-1052
300-1056
530-1619
230-1190
230-1191
340-2262
800-3257

DESCRIPTION

Disk Drive FRU Assembly
• 688MB Disk Drive, CDC 9720-850, PA8K2 1
• Disk Mounting Cradle (obsolete)
• Disk Mounting Cradle
Screw, #10-32 x 1/2"
Kepnut, M4
• DC Harness CDC
• Fan Duct, CDC PA8K2A
• Washer, M5
• Screw, #10-32 x 1/4"
Fan Assembly
Fingerguard
Screw, #6-32 x 1 1/2"
Washer, #6
• Screw, #6-32 x 5/8
LED/Switch Assembly
• Switch Panel
• LED/Switch PCB
Remote Switch Assembly
• Switch Housing
• Switch Block
LED/Switch DC Harness
Caster
M4 0.7 x 10 mm
820W Power Supply 2
410W Power Supply 3
System Grounding Cable, 2.0M
8" Cable Tie
Cable Clip, Snap-in
Cable Restraint Bracket
Sun Expansion Pedestal Field Service Manual

•
•

•
•
•
•

1 The 688MB Disk Drive cannot be used with Power Supply 300-1075.

2 Power Supplies 300-1052-03 and 300-1052-04 do not support the

Fujitsu M2372 Disk Drive. Use 300-1052-05.
3 Power Supplies 300-1056-03 and 300-1056-04 do not support the

Fujitsu M2372 Disk Drive. Use 300-1056-05.

Technical Volume II

OPT-51

PARTS BREAKDOWN

741A 742A

1.2GB Disk

21.2GB Disks

12/90

743A 744A 745A

31.2GB Disks

41.2GB Disks

1.2GB Disk
Standalone

Sun Expansion Pedestal

2

3

8--~=--

7

5

OPT-52

Field Engineer Handbook

12/90

PARTS BREAKDOWN

741A
1.2GB Disk

742A

743A

744A

21.2GB Disks

31.2GB Disks

41.2GB Disks

745A
1.2GB Disk
Standalone

Sun Expansion Pedestal
CODE

PART #

DESCRIPTION

NS
NS
1
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
2
NS
NS
3
NS
NS
NS
4
5
6
7
8
8
NS
NS
NS
NS
NS

340-2188
340-2208
540-1926
370-1314
340-2300
180-1486
240-1207
250-1070
340-1898
330-1192
540-1749
540-1846
540-1847
540-1939
530-1487
530-1488
530-1518
530-1536
370-1275
540-1765
340-2050
501-1531
540-1748
330-1212
330-1213
340-1936
530-1495
340-2129
240-1372
530-1544
300-1052
300-1075
530-1619
340-2262
230-0203
230-1188
800-3257

Rear Panel without Cables
• Filler Panel
IP18-1000 3MB/Sec Disk Drive FRU Assembly
• 1.2GB Disk Drive, Seagate 97209-12G, PA8R2 1
Disk Mounting Cradle
Front Ground Strap
• #10-32 x 1/2" Drive Mounting Screw
• Rear Ground Strap
Top Cover
Disk Bezel Insert
Rear Bumper Assembly
Side Panel Assembly
Rear Bezel Assembly
Front Panel and Bumper Assembly
IPI Drive I/O Cable, 8.0M
IPI Drive I/O Cable, 1.OM
IPI Drive I/O Cable, 2.0M
IPI Drive I/O Cable, 450 mm
IPI Drive Terminator
LED/Switch Assembly
• Switch Panel
• LED/Switch PCB
Remote Switch Assembly
• Switch
• Push Block
• Switch Housing
LED/Switch DC Harness
Caster
M4 0.7 x 10 mm Screw
DC Harness
820W Power Supply (obsolete) 2
840W Power Supply
System Grounding Cable, 2.0M
Cable Restraint Bracket
4" Tiestrap
6" Tiestrap, Snap-in
Sun Expansion Pedestal Field Service Manual

•
•

1 Do not insta1l1P18-1000 Disk Drive, 370-1187, in the Sun Expansion

Pedestal.
2 The 820W Power Supply, 300-1052-05, does not support the 1.2GB

Disk Drive. Use 840W Power Supply, 300-1075.

Technical Volume II

OPT-53

12/90

PARTS BREAKDOWN

741L

911MB Disk

742L

2911MB Disks

743L

744L

3911MB Disks 4911MB Disks

745L

911MB Disk
Stadaione

Sun Expansion Pedestal

3

8----;dE-

7

5

OPT-54

Field Engineer Handbook

12/90

PARTS BREAKDOWN

741L

742L

743L

911 MB Disk

2 911 MB Disks

3 911 MB Disks

744L 745L
4 911 MB Disks

911 MB Disk
Standalone

Sun Expansion Pedestal
CODE

PART #

DESCRIPTION

NS
NS
1
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
NS
2
NS
NS
3
NS
NS
NS
4
5
6
7
8
NS
NS
NS
NS
NS

340-2188
340-2208
540-2008
370-1352
340-2300
180-1486
240-1207
250-1070
340-1898
330-1192
540-1749
540-1846
540-1847
540-1939
530-1487
530-1488
530-1518
530-1536
370-1275
540-1765
340-2050
501-1531
540-1748
330-1212
330-1213
340-1936
530-1495
340-2129
240-1372
530-1544
300-1075
530-1619
340-2262
230-0203
230-1188
800-3257

Rear Panel without Cables
• Filler Panel
IPI8-1000/2HP 6MB/Sec Disk Drive FRU Assembly
• 911MB Disk Drive. Sea gate 97209-11G. PA8Y2
• Disk Mounting Cradle
• Front Ground Strap
• #10-32 x 1/2" Drive Mounting Screw
• Rear Ground Strap
Top Cover
Disk Bezel Insert
Rear Bumper Assembly
Side Panel Assembly
Rear Bezel Assembly
Front Panel and Bumper Assembly
IPI Drive I/O Cable. 8.0M
IPI Drive I/O Cable. 1.0M
IPI Drive I/O Cable. 2.0M
IPI Drive I/O Cable. 450 mm
IPI Drive Terminator
LED/Switch Assembly
• Switch Panel
• LED/Switch PCB
Remote Switch Assembly
• Switch
• Push Block
• Switch Housing
LED/Switch DC Harness
Caster
M4 0.7 x 10 mm Screw
DC Harness
840W Power Supply 2
System Grounding Cable. 2.0M
Cable Restraint Bracket
4" Tiestrap
6" Tiestrap. Snap-in
Sun Expansion Pedestal Field Service Manual

1

Do not install IPI8-1000/2HP Disk Drive. 370-1351. in the Sun Expansion
Pedestal.
2 The 820W Power Supply. 300-1052. does not support the 911 MB Disk
Drive. Use 840W Power Supply. 300-1075.
1

Technical Volume II

OPT-55

PARTS BREAKDOWN

941
1 Drive

12/90

942

943

944

945

946

2 Drives

3 Drives

4 Drives

Exp Drive
without Tray

Exp Drive
with Tray

892MB SMD Disk Subsystem
PART #

DESCRIPTION

340-1628
340-1728
340-1682
340-1689
530-1475
530-1476
530-1354
530-1355
530-1356

Disk Drive Mounting Tray (obsolete)
Disk Drive Mounting Tray
Support Bracket, Right
Support Bracket, Left
SMD Data Cable, 600M, Xylogics 7053
SMD Command Cable, 600M, Xylogics 7053
SMD Command Cable, 205M, Xylogics 7053
SMD Data Cable, 205M, Xylogics 7053
SMD Daisy Chain Command Cable, 205M

555-1008
180-1097
240-1655
240-1666
340-1683
340-1712
340-1721
370-1140
370-1141
370-1141
370-1141
370-1162
370-1163
530-1343
530-1351
540-1637
540-1638
580-1179
813-1036
813-2046

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

OPT-56

892MB Disk Drive Assembly
AC Power Cord (115V)
SAE #10-32 x 5/16" Screw (x3)
SAE #8-32 x 5/16" Screw (x16)
Slide Rail, NEC D2363
Stop Bracket, Hitachi DK815-10 & DK815-10A
Slide Rail, Hitachi DK815-10 & DK815-10A
892MB Disk Drive, NEC D2363
892MB Disk Drive, NEC D2363
892MB Disk Drive, Hitachi DK815-10
892MB Disk Drive, Hitachi DK815-10A
Terminator, Hitachi DK815-10 & DK815-10A
Terminator, NEC D2363
AC Power Cord (240V)
AC Power Cord (230V)
Mounting Hardware Kit, NEC D2363
Mounting Hardware Kit, Hitachi DK815-10 & DK815-10A
892MB Disk Drive Packaging
892MB Disk Drive Insta"ation Manual
892MB Disk Drive Configuration Manual

Field Engineer Handbook

12/90

PARTS BREAKDOWN

084

084TC

084EX

TC

65MB Disk

65MB Disk
20MB Tape

65MB Disk
Expansion

20MB Tape

Rackmountable Disk and Tape Subsystem
PART

140-1024
150-0137
180-1097
180-1125
300-0566
300-1014
340-1274
370-0172
370-0242
370-0567
370-0544
370-0544
530-0139
530-0554
530-0555
530-0607
530-1043
530-1046
530-1047
530-0241

DESCRIPTION

Fuse, 5A (115V)
AC Filter/Fuse/Switch
AC Power Cord (115V)
AC Power Cord (240V)
170 Watt Power Supply (obsolete)
250 Watt Power Supply
Mounting Bracket for 300-1014 Power Supply
AC Fan (115V), 75 CFM
AC Fan (240V), 75 CFM
65MB SMD Disk Drive, Fujitsu M2312K
20MB 1/4" Tape Drive, QIC-11, Archive 9020
20MB 1/4" Tape Drive, QIC-11, Cipher F420-90
AC Harness, AC Filter to Power Supply
DC Harness, Power Supply to Disk Drive
DC Harness, Power Supply to Tape Drive
SMD Daisy Chain Cable
Tape Command Cable, 1.0M
SMD Command Cable, 1.0M
SMD Data Cable, 1.0M
AC Harness, AC Fan

Technical Volume II

OPT-57

12/90

PARTS BREAKDOWN

LW110

LW220

LW240

115V LaserWriter

220V LaserWriter

240V LaserWriter

SUNlLW-1

SUNILW-2

SUN/LW-3

115V LaserWriter

220V LaserWriter

240V LaserWriter

LaserWriter I
PART

DESCRIPTION

540-1253
260-1369
260-2017
370-1041
811-1247

LaserWriter I Assembly (115V)
Sun Logo
Label Kit
LaserWriter I (115V)
Letter/Legal Paper Tray

540-1271
260-1369
260-2017
370-1042

LaserWriter J Assembly (240V)
Sun Logo
Label Kit
LaserWriter I (240V)

150-1121
530-1172
530-1433

LaserWriter J Toner Cartridge
LaserWriter Cable, 08-25 Male to 08-25 Male
LaserWriter Cable, 08-25 Male to 08-25 Female

OPT-58

Field Engineer Handbook

12/90

PARTS BREAKDOWN

LW-1
115V LaserWriter

LW-2

LW-3

240V LaserWriter

115V LaserWriter
A4 Paper Tray

LaserWriter II
PART #

DESCRIPTION

365-1040
370-1189
370-1196
536-1003
350-1015
330-1162
330-1163

LaserWriter II Assembly, A4 Paper Tray (240V)
• LaserWriter II Print Engine (240V)
• NT Controller PCA
• AC Power Cord (240V)
• A4 Paper Tray Assembly
• A4 Paper Tray Base
• A4 Paper Tray Top

365-1041
370-1188
370-1196
536-1002
350-1014
330-1160
330-1161

LaserWriter II Assembly, Letter/Legal Paper Tray (115V)
• LaserWriter II Print Engine (115V)
• NT Controller PCA
• AC Power Cord (115V)
• Letter/Legal Paper Tray Assembly
• Letter/Legal Paper Tray Base
• Letter/Legal Paper Tray Top

365-1067
370-1188
370-1196
536-1002
350-1015
330-1162
330-1163

LaserWriter II Assembly, A4 Paper Tray (115V)
• LaserWriter II Print Engine (115V)
• NT Controller PCA
• AC Power Cord (115V)
• A4 Paper Tray Assembly
• A4 Paper Tray Base
• A4 Paper Tray Top

150-1279
530-1172
530-1433

Las~rWriter II Toner Cartridge
LaserWTiter Cable, OB-25 Male to OB-25 Male
LaserWriter Cable, OB-25 Male to OB-25 Female

Technical Volume II

OPT-59

PARTS BREAKDOWN

12/90

RR127

RR128

RR129 RREXP RREXP-P7

Empty

60MB Tape

60MB Tape
327MB Disk

60MB Tape

60MB Tape
327MB Disk

Sun386i Expansion Unit
PART #

DESCRIPTION

150-1556
300-1031
340-1960
350-1006
350-1010
350-1011
350-1013
350-1117
370-1247
530-1365
530-1371
530-1381
530-1409
530-1461
530-1618
530-1659
570-1042
814-5036

SCSI ID Select Switch
120 Watt Power Supply
Half-Height Peripheral Front Filler Panel (obsolete)
Top Cover
Left Side Cover
Front Bezel
Right Side Cover
Rear Bezel
45/60MB 1/4" Tape Drive with MT02, Full-Height. QIC-11/24
External SCSI Cable, DD-50SA to DD-50SA, 41 cm
AC Power Cord, System Chassis to Peripheral Chassis
External Terminator
Internal SCSI Cable (obsolete)
1/4" Tape Drive Adapter Cable
Internal SCSI Cable
SCSI ID Select Switch Cable
Full-Height Peripheral Front Filler Panel
Replacing Components of Sun ESM and EEM Storage Units

555-1004
330-1146
330-1158
370-1148

91 MB SCSI Disk Drive FRU Assembly
• Mounting Bracket
• Drive Removal Handle
• 91 MB Disk Drive, Imprimis/CDC 77765863

555-1005
330-1146
330-1158
370-1153

• Mounting Bracket
• Drive Removal Handle
• 327MB Disk Drive, Imprimis/CDC 77777107

555-1059
330-1146
330-1158
370-1191

155MB SCSI Disk Drive FRU Assembly
• Mounting Bracket
• Drive Removal Handle
• 155MB Disk Drive, Imprimis/CDC 77774677

OPT-60

327MB SCSI Disk Drive FRU Assembly

Field Engineer Handbook

12/90

PARTS BREAKDOWN

RR131

RR132

RR133

RR134

155MB Disk

60MB Tape

91MB Disk

327MB Disk

Add-On Sun386i Options
PART #

DESCRIPTION

555-1004
330-1146
330-1158
370-1148

91 MB SCSI Disk Drive FRU Assembly
• Mounting Bracket
• Drive Removal Handle
• 91 MB Disk Drive, Imprimis/CDC 77765863

555-1005
330-1146
330-1158
370-1153

• Mounting Bracket
• Drive Removal Handle
• 327MB Disk Drive, Imprimis/CDC 77777107

555-1059
330-1146
330-1158
370-1191

155MB SCSI Disk Drive FRU Assembly
• Mounting Bracket
• Drive Removal Handle
• 155MB Disk Drive, Imprimis/CDC 77774677

570-1018
370-1247
530-1461

45/6OMB 1/4" Tape Drive Assembly
• 45/60MB 1/4" Tape Drive with MT02, Full-Height
• 1/4" Tape Drive Adapter Cable

327MB SCSI Disk Drive FRU Assembly

Technical Volume II

OPT-61

PARTS BREAKDOWN

12/90

SPRN-400
SPARCprinter
PART #

365-1089
365-1124
365-1125
365-1126
365-1127
370-1365
410-1017
501-1540
530-1680
530-1683
530-1694
811-1345
811-1316

DESCRIPTION

SPARCprinter (115V & 240V)
Toner Cartridge 1
Drum Cartridge 2
Universal Paper Tray
B4 Paper Tray
Video Port Cable, Video Port to SPARCprinter
Reusable Field Service Transit Case
SBus Printer Board
Parallel Port Cable
Loopback Test Cable, Parallel Port to Video Port
Test Cable, Video Port to Video Port
Front Cover
Corotron Assembly

1 The life of the Toner Cartridge is 8000 pages. A J5 error code

indicates a low toner condition. Reset the display when a new Toner
Cartridge is installed.
a. Turn the AC power OFF.
b. Replace the Toner Cartridge.
c. Turn the AC power ON.
d. Press the Reset button located next to the power switch.
2 The life of the Drum Cartridge is 20,000 pages. Reset the print counter

when a new Drum Cartridge is installed.
a. Turn the AC power OFF.
b. Install a new Drum Cartridge.
b. Press and hold the Reset button located next to the power switch.
c. Turn the AC power ON.
d. Release the Reset button.
Do not reset the print counter unless a new Drum Cartridge is
installed. Resetting the print counter without replacing the Drum
Cartridge causes mechanical damage to the SPARCprinter when
the toner sump fills.

OPT-62

Field Engineer Handbook

12/90

PARTS BREAKDOWN

SUNIPC-FPY1
Single Floppy Subsystem

SUNIPC-FPY2
Dual Floppy Subsystem

Sun Integrated Personal Computer
PART

330-1096
370-1118
370-1119
370-1125
501-1125
501-1214

DESCRIPTION

Sun Type 3 Keyboard Template
Single 5 1/4" Floppy Subsystem
Dual 5 1/4" Floppy Subsytem
External Command Cable
PCIAT - Compatable Coprocessor Board
PCI AT- Compatable Coprocessor Board with 80287

Technical Volume II

OPT-63

12/90

PARTS BREAKDOWN

GT Graphics Tower
3-Slot VMEbus Logic Enclosure
PART #

140-1019
140-1030
150-1042
150-1051
180-1097
180-1125
330-1067
330-1069
330-1071
330-1089
330-1144
340-1545
370-1178
501-1127
530-1684
540-2061
240-1372
540-1418
300-1022
300-1022
540-2051
501-1773
540-2055
540-1535
800-5264

DESCRIPTION

Fuse, 15A (115V)
Fuse, 6.3A (240V)
Fusecarrier (115V)
Fusecarrier (240V)
AC Power Cord (115V)
AC Power Cord (240V)
End Panel, 42 cm X 11 cm
Front Bezel
Side Panel, 42 cm X 59 cm
Side Panel Screw
Backplane Shield
Air Filter Assembly
AC Switch & Fuse & Filter Assembly
3-Slot VMEbus Backplane, Pressfit
SBus HSA to HGPFE Cable, 1.5M
Power Supply Module Assembly (115V)
• Screw, M4 0.7 x 10mm
• Power Supply Module Assembly (115V)
• 325 Watt Power Supply, Summit
• 325 Watt Power Supply, Brown
DC Fan Tray Assembly, 4 Fans
• Fan Controller PCB
• DC Fan Assembly, 44 CFM
3-Slot Foot Assembly
Service Manual for the GT Graphics Subsystem

Notes
1. Do not install the GT Graphics Option Board Set in the Sun-3/11 0,
Sun-3/140, Sun-4/110, or Sun-4/310 3-Slot Logic Enclosure. The
three fan tray does not provide adaquate cooling.
2. The GT Graphics Option Board Set is not supported in the
Sun-3/150, Sun-4/150, or Sun-4/350 6-Slot Logic Enclosure.

OPT-64

Field Engineer Handbook

PARTS BREAKDOWN

BOARD

PARTS BREAKDOWN

12/90

Board
CPU
Sun-1
Sun-3
Sun-4
Sun-4

68000 and Sun-2 68010 . . . . . . . . . . . ..
68020 and Sun-3x 68030 ...........
SPARC ...........................
SPARC ...........................

3
4
5
8

MEMORY
Multibus and VMEbus . . . . . . . . . . . . . . . . . . . . .. 7
VMEbus and Sun386i . . . . . . . . . . . . . . . . . . . . .. 8
Sun-4/330 and VMEbus . . . . . . . . . . . . . . . . . . .. 9
SIMMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 10
VIDEO
Multibus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
P4 Bus ................................
Sun386i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
VMEbus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
SBus ..................... . . . . . . . . . . . ..
SBus and VMEbus Combination ............
Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..

11
11
11
12
13
14
15

DISK CONTROLLER .......................

16

TAPE CONTROLLER . . . . . . . . . . . . . . . . . . . . . ..

18

COMMUNICATION
Ethernet and FDDI .......................
Multibus ALM and SCP . . . . . . . . . . . . . . . . . . ..
VMEbus ALM and SCP ...................
ALM-2.................................
MCP ..................................
HSI ....................................
Channel Adapter .........................
SBus . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . ..

Field Engineer Handbook - Technical Volume II

19
20
21
22
22
22
22
23

12/90

PARTS BREAKDOWN

Board - Continued
SCSI HOST ADAPTER

Boards and Cables. . . . . . . . . . . . . . . . . . . . . . ..
Assemblies ..............................

24
25

BACKPLANE .............................

26

MISCELLANEOUS .........................

27

BD-2

Field Engineer Handbook

12/90

PARTS BREAKDOWN

CPU
Sun-1 68000 and Sun-2 68010
PART #

DESCRIPTION

501-0001
501-0002
501-0004
501-0600

256KB
256KB
256KB
256KB

Sun-1 68000 CPU
Sun-1 68000 CPU, TI
Sun-1 68000 CPU, Kontron
Sun-1.5 68010 CPU (obsolete, unsupported)

501-1007
501-1051

Sun-2 68010 CPU
Sun-2 68010 CPU

501-1005
540-1101
599-1182
501-1141
501-1142
599-1183
501-1143
599-1184
501-1072

1MB
1MB
1MB
1MB
2MB
2MB
4MB
4MB
4MB

Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50

501-1144
599-1168
501-1145
599-1169
501-1146
599-1170

1MB
1MB
2MB
2MB
4MB
4MB

Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160

Technical Volume II

CPU (obsolete)
CPU (obsolete)
CPU (obsolete)
CPU
CPU
CPU (obsolete)
CPU
CPU (obsolete)
CPU, 1024x1024 Monochrome Video
CPU
CPU (obsolete)
CPU
CPU (obsolete)
CPU
CPU (obsolete)

BD-3

PARTS BREAKDOWN

12/90

CPU
Sun-3 68020 and Sun-3x 68030
PART #

DESCRIPTION

S99-1220
S99-1267
S01-107S
S01-1133
S01-1162
S01-1207
S99-1219
S99-1268
S99-1309

2MB
2MB
4MB
4MB
4MB
4MB
4MB
4MB
4MB

Sun-3/S0,
Sun-3ISO,
Sun-3/S0,
Sun-3/S0,
Sun-3/S0,
Sun-3/S0,
Sun-3/S0,
Sun-3/S0,
Sun-3/S0,

S01-1205
501-1322
S01-1334
S01-134S

4MB
4MB
OMB
OMB

Sun-3/60
Sun-3/60
Sun-3/60
Sun-3/60

CPU
CPU
CPU
CPU

S99-1177
S99-1178
501-1074
S01-1094
S01-1163
S01-1164
S01-1208

2MB
4MB
2MB
4MB
2MB
4MB
4MB

Sun
Sun
Sun
Sun
Sun
Sun
Sun

CPU,
CPU,
CPU,
CPU,
CPU,
CPU,
CPU,

S01-1134
S01-1209

4MB Sun-3/11 0 CPU
4MB Sun-3/11 0 CPU

501-1100
S01-1206

OMB Sun 3200 CPU
OMB Sun 3200 CPU

501-1299
501-1S50

OMB Sun 3400 CPU (obsolete)
OMB Sun 3400 CPU

S01-1401
S01-1650

4MB Sun-3/80 CPU
4MB Sun-3/80 CPU

BD-4

3004
3004
3004
3004
3004
3004
3004

12.SMhz without 12.SMhz 68881 (obsolete)
12.SMhz or 16.67Mhz w 12.SMhz 68881 (obs)
12.SMhz without 12.SMhz 68881 (obsolete)
12.S or 16.67Mhz w/o 12.SMhz 68881 (obs)
16.67Mhz without 16.67Mhz 68881
16.67Mhz with 16.67Mhz 68881
12.SMhz without 12.SMhz 68881 (obsolete)
12.SMhz or 16.67Mhz w 12.SMhz 68881 (obs)
16.67Mhz with 16.67Mhz 68881 (obsolete)
with Monochrome Video, 1MB SIMMs
without Monochrome Video, 1MB SIMMs
with Monochrome Video
without Monochrome Video
12.SMhz 68881 (obsolete)
12.SMhz 68881 (obsolete)
12.SMhz 68881 (obsolete)
12.SMhz 68881 (obsolete)
16.67Mhz 68881
16.67Mhz 68881
16.67Mhz 68881

Field Engineer Handbook

12/90

PARTS BREAKDOWN

CPU
Sun-4 SPARe
PART #

DESCRIPTION

501-8058
501-8035

4MB Sun-4/E CPU without Weitek Floating Point
4MB Sun-4/E CPU with Weitek Floating Point

501-1627
501-1680
501-1727
501-1720
501-1748
501-1776
501-1777
530-1677
530-1696
530-1702

8MB Sun-4/20 CPU
OMB Sun-4/20 CPU
OMB Sun-4/20 CPU with packaging (obsolete)
8MB Sun-4/20 CPU
OMB Sun-4/20 CPU
8MB Sun-4/20 CPU
OMB Sun-4/20 CPU
• Serial Port Adapter Cable, DB-25 to 2x D8-25
• Ethernet Adapter Cable, 2.0M
• Audio Cable, Mini-Din to Mini-Jack

501-1689
501-1690
501-1835
530-1594
530-1662

8MB Sun-4/40 CPU
OMB Sun-4/40 CPU (obsolete)
8MB Sun-4/40 CPU
• Audio Cable, Mini-Din to Mini-Jack
• RS-232 Cable, 1.0 M, Mini-Din to DB-25

501-1382
501-1629
530-1594

8MB Sun-4/60 CPU
8MB Sun-4/60 CPU
• Audio Cable, Mini-Din to Mini-Jack

501-1632
501-1691
530-1594

8MB Sun-4/65 CPU
OMB Sun-4/65 CPU
• Audio Cable, Mini-Din to Mini-Jack

501-1638
501-1744
530-1594

16MB Sun-4/75 CPU
OMB Sun-4/75 CPU
• Audio Cable, Mini-Din to Mini-Jack

Technical Volume II

BD-5

PARTS BREAKDOWN

12/90

CPU
Sun-4 SPARe
PART #

DESCRIPTION

501-1199
501-1512
501-1656
501-1237
501-1513
501-1657
501-1462
501-1514
501-1658
501-1463
501-1515
501-1659
501-1464
501-1516
501-1660
501-1465
501-1517
501-1661

8MB Sun 4100 CPU without FPC
8MB Sun 4100 CPU without FPC
8MB Sun 4100 CPU without FPC
8MB Sun 4100 CPU with FPC4 or FPC6
8MB Sun 4100 CPU with FPC4 or FPC6
8MB Sun 4100 CPU with FPC6
16MB Sun 4100 CPU without FPC
16MB Sun 4100 CPU without FPC
16MB Sun 4100 CPU without FPC
16MB Sun 4100 CPU with FPC4 or FPC6
16MB Sun 4100 CPU with FPC4 or FPC6
16MB Sun 4100 CPU with FPC6
32MB Sun 4100 CPU without FPC
32MB Sun 4100 CPU without FPC
32MB Sun 4100 CPU without FPC
32MB Sun 4100 CPU with FPC4 or FPC6
32MB Sun 4100 CPU with FPC4 or FPC6
32MB Sun 4100 CPU with FPC6

501-1129
501-1274
501-1491
501-1522

OMB
OMB
OMB
OMB

501-1316
501-1742

8MB Sun 4300 CPU with 1MB SIMMs
32MB Sun 4300 CPU with 4MB SIMMs

501-1381

OMB Sun 4400 CPU

BD-6

Sun
Sun
Sun
Sun

4200
4200
4200
4200

CPU
CPU
CPU
CPU

with
with
with
with

FPC4 (obsolete)
FPC4 or FPC6. 1-Slot Backpanel
FPU-2. 2-Slot Backpanel
FPC4 or FPC6. 2-Slot Backpanel

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Memory
Multibus and VMEbus
PART #

DESCRIPTION

370-0147
501-0147
501-0147
501-0147

256KB Chrislin Multibus Memory
256KB Sun-1 Parity Memory (501-0147-07)
768KB Sun-1 Parity Memory (501-0147-05)
1MB Sun-1 Parity Memory (501-0147-06)

501-1013
501-1048
501-1232

1MB Sun-2 Parity Memory. Multibus
1MB Sun-2 Parity Memory. Multibus
4MB Sun-2 Parity Memory. Multibus

501-1079
501-1020
540-1101
540-1103
599-1182
599-1069
501-1046
599-1067
501-1067
540-1104
599-1092
501-1047
599-1068

OMB
1MB
1MB
1MB
1MB
1MB
2MB
2MB
3MB
3MB
3MB
4MB
4MB

Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50
Sun-2/50

501-1070
540-1113
599-1115
501-1096
599-1163
501-1071
540-1114
599-1116
501-1097
599-1164

1MB
1MB
1MB
2MB
2MB
3MB
3MB
3MB
4MB
4MB

Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160
Sun-2/130/160

Technical Volume II

Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity

Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity
Parity

(obsolete)
(obsolete)
(obsolete)
(obsolete)
(obsolete)
(obsolete)
(obsolete)
(obsolete)

Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory
Memory

(obsolete)
(obsolete)
(obsolete)
(obsolete)
(obsolete)
(obsolete)

BD-7

12/90

PARTS BREAKDOWN

Memory
VMEbus and Sun386i
PART #

DESCRIPTION

501-1121
599-1242
501-1111
599-1240
501-1122
599-1241

OMB
OMB
2MB
2MB
4MB
4MB

Sun
Sun
Sun
Sun
Sun
Sun

3/75
3/75
3/75
3/75
3/75
3/75

Parity
Parity
Parity
Parity
Parity
Parity

Memory
Memory
Memory
Memory
Memory
Memory

501-1131
599-1179
599-1188
501-1132
599-1180
599-1189

2MB
2MB
2MB
4MB
4MB
4MB

Sun
Sun
Sun
Sun
Sun
Sun

3004
3004
3004
3004
3004
3004

Parity
Parity
Parity
Parity
Parity
Parity

Memory
Memory
Memory
Memory
Memory
Memory

501-1102
501-1254
501-1576
501-1451

8MB Sun 3200 & Sun 3400, Sun 4200 ECC Memory
32MB Sun 3200 & Sun 4200 ECC Memory
16MB Sun 3200, Sun 3400 & Sun 4200 ECC Memory
32MB Sun 3200, Sun 3400 & Sun 4200 ECC Memory

501-8031
501-8030

4MB Sun-3/E Parity Memory
12MB Sun-3/E Parity Memory

555-1423
501-1394
501-1441

OMB Sun386i Rarity Memory
4MB Sun386i Parity Memory
8MB Sun386i Parity Memory

501-1482
555-1054
501-1325
501-1298

OMB
OMB
4MB
8MB

BD-8

Sun386i
Sun386i
Sun386i
Sun386i

Parity
Parity
Parity
Parity

Memory
Memory
Memory
Memory

(obsolete)
(obsolete)
(obsolete)
(obsolete)

(obsolete)
(obsolete)
(obsolete)
(obsolete)

with
with
with
with

Cache
Cache
Cache
Cache

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Memory
Sun-4/330 and VMEbus
PART #

DESCRIPTION

501-1436
501-1723
501-1711
501-1317
501-1704
501-1755

8MB Sun-4/330 Parity Memory with 1MB SIMMs
8MB Sun-4/330 Parity Memory with 1MB SIMMs
16MB Sun-4/330 Parity Memory with 1MB SIMMs
16MB Sun-4/330 Parity Memory with 1MB SIMMs
32MB Sun-4/330 Parity Memory with 4MB SIMMs
32MB Sun-4/330 Parity Memory with 4MB SIMMs

501-1564
501-1563
501-1703
501-1495

8MB Sun 4300 Memory, with 1MB SIMMs
24MB Sun 4300 Memory with 1MB SIMMs
32MB Sun 4300 Memory with 4MB SIMMs
48MB Sun 4300 Memory with 1MB SIMMs

501-1333
501-1721

32MB Sun 4400 ECC Memory
128MB Sun 4400 ECC Memory

501-8036
501-8042
501-8060

16MB Sun-4/E ECC Memory
4MB Sun-4/E ECC Memory
OMB Sun-4/E Combo Parity Memory & 2-Slot SBus Expansion

Technical Volume II

BD-9

12/90

PARTS BREAKDOWN

Memory
SIMMs
PART #

501-1239
501-1349
501-1346
501-1314
501-1466
501-1424
501-1375
501-1510
501-1408
501-1544
501-1565
501-1676
501-1698
501-1625
501-1682
501-1697
501-1739

BD-10

DESCRIPTION

1MB x
256KB
1MB x
256KB
1MB x
1MB x
1MB x
1MB x
1MB x
1MB x
1MB x
4MB x
4MB x
4MB x
4MB x
1MB x
4MB x

9-Bit SIMM, Sun-3/60
x 9-Bit DIP SIMM, Sun-3/60LE
9-Bit DIP SIMM, Sun-3/60LE
x 9-Bit SIMM, Sun 4100
9-Bit SIMM, Sun 4100 & Sun 4300
9-Bit SIMM, Sun386i1150 & Sun386i/250
9-Bit SIMM, Sun386i1250
9-Bit SIMM, Sun386i1250
9-Bit SIMM, Sun-3/80, Sun-4/60 & Sun-4/65
9-Bit SIMM, Sun 4300
9-Bit SIMM, Sun 4300
36-Bit SIMM, Sun-4/20
36-Bit SIMM, Sun-4/20
9-Bit SIMM, Sun-4/40, Sun-4/60 & Sun-4/65
9-Bit SIMM, Sun 4300
9-Bit SIMM, Sun-4/40
9-Bit SIMM, Sun-4/75

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Video
Multibus
PART #

P4 Bus

Sun386i

DESCRIPTION

501-0059
501-0461
501-1003
501-1052

Sun-1
Sun-2
Sun-2
Sun-2

Multibus Monochrome Frame Buffer
Multibus Color Frame Buffer
Multibus Monochrome Frame Buffer
Prime Multibus Monochrome Frame Buffer

501-1210
501-1247
501-1248
501-1371
501-1402
501-1443
501-1483
501-1518
501-1577
501-1637

CG4 Color Frame Buffer, BNC (Sun-3/60 Only)
MG3 ECl Monochrome Frame Buffer, DB-9
CG4 Color Frame Buffer, BNC
CG8 Color Frame Buffer, DB13W3
MG4 ECUAnalog Monochrome Frame Buffer, DB-9/DB13W3
CG4 Color Frame Buffer, BNC, Sun-3/80 Backpanel
DC to DC Converter for MG3
CG8 Color Frame Buffer, BNC
CG8 Color Frame Buffer, DB13W3, Sun-3/80 Backpanel
MG3 ECl Monochrome Frame Buffer, DB-9, Sun-3/80 Backpanel

501-1374
501-1505
501-1532

GX Graphics Option
CG6 Color Frame Buffer, DB13W3
CG6 Color Frame Buffer, DB13W3
CG6 Color Frame Buffer, DB13W3

501-1243
501-1244
501-1286
501-1352
501-1397
501-1443
501-1567
501-1568

Sun386i
Sun386i
Sun386i
Sun386i
Sun386i
Sun386i
Sun386i
Sun386i

Color Frame Buffer, 1152x900
Monochrome Frame Buffer, 1152x900
Color Frame Buffer, 1024x768
GXi Graphics Accelerator
SunVGAlEGA
Monochrome Frame Buffer, 1024x768
Monochrome Frame Buffer, 1152x900
Monochrome Frame Buffer, 1024x768

Technical Volume II

BD-11

12/90

PARTS BREAKDOWN

Video
VMEbus
PART #

DESCRIPTION

501-1014
540-1126
599-1165
501-1089
501-1116
501-1319
501-1267
501-1055
501-1139
501-1268
501-1058
501-8020
501-8029
501-1383
501-1447

CG2 Color Frame Buffer
CG2 Color Frame Buffer (obsolete)
CG2 Color Frame Buffer (obsolete)
CG3 Double Buffered Color Frame Buffer
CG3 Color Frame Buffer
CG3 Double Buffered Color Frame Buffer, 1024x1024
CG5 Color Frame Buffer
GP Graphics Processor
GP+ Graphics Processor Plus
GP2 Graphics Processor Two
GB Graphics Buffer
Sun-3/E Monochrome Frame Buffer
Sun-3/E Color Frame Buffer
TAAC-1 Application Accelerator
TAAC-1 Application Accelerator

501-1116
501-1139
501-1268

CXP Graphics Option
CG3 Color Frame Buffer
GP+ Graphics Processor Plus
GP2 Graphics Processor Two

501-1434
501-1268

GXP Graphics Option
CG9 24-bit Color Frame Buffer
GP2 Graphics Processor Two

501-1537
501-1538
501-1596

MVX Graphics Option
Visualization Accelerator Pixel Processor
Visualization Accelerator Super Frame Buffer
Visualization Accelerator Interconnect Board

501-1538

VX Graphics Option
Visualization Accelerator Super Frame Buffer

BD-12

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Video
SBus
PART #

DESCRIPTION

501-1415
501-1718
501-8044
501-1419
501-8043
501-1455
501-1561
501-1706

CG3 8-bit Color Frame Buffer, DB13W3, 66Hz
CG3 8-bit Color Frame Buffer, DB13W3, 66/76Hz
CG3 8-bit Color Frame Buffer, DB13W3, 66Hz, Sun-4/E
MG1 1-bit ECl Monochrome Frame Buffer, DB-9, 66Hz
MG1 1-bit ECl Monochrome Frame Buffer, DB-9, 66Hz, Sun-4/E
MG2 1-bit Analog Monochrome Frame Buffer, DB13W3, 66Hz
MG2 1-bit Analog Monochrome Frame Buffer, DB13W3, 66/76Hz
VideoPics, 2x RCA

370-1329

GS Graphics Option
CG12 24-Bit Color Frame Buffer, DB13W3, 76Hz

501-1481
501-1645
501-1672

GX Graphics Option
CG6 8-bit Color Frame Buffer, DB13W3, 66Hz (Sun-4/60 only)
CG6 8-bit Color Frame Buffer, DB13W3, 66Hz
CG6 8-bit Color Frame Buffer, DB13W3, 66/76Hz

Technical Volume II

BD-13

PARTS BREAKDOWN

12/90

Video
SBus and VMEbus Combination
PART #

501-1624
501-1692
501-1693
501-1694
501-1726
530-1684

BD-14

DESCRIPTION

GT Graphics Option
Frame Buffer, DB13W3 & DB5W5, 76Hz
Graphics Processor Front End (GPFE)
SBus GT Adapter
GPFE to GPRP Connector
Graphics Processor Rendering Pipeline (GPRP)
SBus Adapter to GPFE Cable, 1.5M

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Video
Cables
PART #

DESCRIPTION

530-0492
530-1138
530-1307
530-1362
530-1415
530-1440
530-1446
530-1509

Color
Color
Color
Color
Color
Color
Color
Color

Video
Video
Video
Video
Video
Video
Video
Video

Cable, 4.6M, 1xBNC to 1xBNC
Cable, 4.6M, 4xBNC to 4xBNC
Cable, 4.6M, 4xBNC to 4xBNC
Cable, 1.2M, 4xBNC to 4xBNC
Cable, 50 cm, 4xBNC to 4xBNC
Cable, 1.2M, OB13W3 to OB13W3
Adapter Cable, 4xBNC to OB13W3
Cable, 4.6M, OB13W3 to OB13W3

530-1308
530-1363
530-1511

Greyscale Video Cable, 4.6M, 2xBNC to 2xBNC
Greyscale Video Cable, 1.2M, 2xBNC to 2xBNC
Greyscale Video Adapter Cable, 2xBNC to OB13W3

530-1041
530-1109
530-1125
530-1133
530-1242
530-1336
530-1359

TTL
ECl
TTL
ECl
ECl
ECl
ECl

530-1366
530-1383
530-1621

Color Video & Keyboard Cable, OB21W3 to 4xBNC (386i)
Monochrome Video & Keyboard Cable, OB21W3 to OB-9 (386i)
Color Video & Keyboard Cable, OB21W3 to OB13W3 (386i)

Monochrome
Monochrome
Monochrome
Monochrome
Monochrome
Monochrome
Monochrome

Technical Volume II

Video
Video
Video
Video
Video
Video
Video

Cable,
Cable,
Cable,
Cable,
Cable,
Cable,
Cable,

OB-9 to OB-9 (Sun-2/150U)
0.75M, OB-9 to OB-9
4.6M, OB-9 to OB-9
4.6M, OB-9 to OB-9
0.75M, OB-9 to OB-9
4.6M, OB-9 to OB-9
1.2M, OB-9 to OB-9

BD-15

PARTS BREAKDOWN

12/90

Disk Controller

PART #

DESCRIPTION

370-1010
370-0552
370-1236
370-1012
370-1082

Adaptec AC8-4000 SCSI Disk Controller
Emulex MD-21 SCSI Disk Controller
Emulex MD-21 SCSI Disk Controller
Xylogics 450 Multibus SMD Disk Controller
Xylogics 451 Multibus SMD Disk Controller

501-1154
530-1147
530-1148
501-1186
370-1012
530-1079
530-1080
530-1209
530-1210

Xylogics 450 VMEbus SMD Disk Controller Assembly
• SMD Data Cable, 9U Adapter Assembly
• SMD Command Cable, 9U Adapter Assembly
• 9U VME Adapter Assembly for Xylogics 450/451
• Xylogics 450 Multibus SMD Disk Controller
• External SMD Command Cable, 0.7M
• External SMD Data Cable, 0.7M
• External SMD Command Cable, 2.0M
• External SMD Data Cable, 2.0M

501-1166
530-1147
530-1148
501-1186
370-1082
530-1079
530-1080
530-1209
530-1210
530-1378
530-1379
530-1356

Xylogics 451 VMEbus SMD Disk Controller Assembly
• SMD Data Cable, 9U Adapter Assembly
• SMD Command Cable, 9U Adapter Assembly
• 9U VME Adapter Assembly for Xylogics 450/451
• Xylogics 451 Multibus SMD Disk Controller
• External SMD Command Cable, 0.7M
• External SMD Data Cable, 0.7M
• External SMD Command Cable, 2.0M
• External SMD Data Cable, 2.0M
• External SMD Command Cable, 892MB Disk Drive
• External SMD Data Cable, 892MB Disk Drive
• External SMD Daisy Chain Command Cable, 892MB Disk Drive

BD-16

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Disk Controller

PART #

DESCRIPTION

501-1249
530-1330
530-1330
530-1330
530-1331
530-1331
530-1331
530-1475
530-1476
530-1354
530-1355
530-1356
530-1692
530-1693

Sun VME/SMD Disk Controller, Xylogics 7053-105
• SMD Data Cable, 2.0M, Mass Storage Pedestal
• SMD Data Cable, 2.0M, Sun Expansion Pedestal
• SMD Data Cable, 2.0M, 575MB Disk Drive
• SMD Command Cable, 2.0M, 575MB Disk Drive
• SMD Command Cable, 2.0M, Sun Expansion Pedestal
• SMD Command Cable, 2.0M, Mass Storage Pedestal
• SMD Data Cable, 6.0M, 892MB Disk Drive
• SMD Command Cable, 6.0M, 892MB Disk Drive
• SMD Command Cable, 2.5M, 892MB Disk Drive
• SMD Data Cable, 2.5M, 892MB Disk Drive
• SMD Daisy Chain Command Cable, 2.5M, 892MB Disk Drive
• SMD Data Cable, 6.0M, 575MB Disk Drive
• SMD Command Cable, 6.0M, 575MB Disk Drive

501-1539
501-1855
530-1487
530-1518
530-1536
530-1488
530-1489

ISP-80 IPI-2 Disk Controller
ISP-80 IPI-2 Disk Controller
• IPI Command Cable, 8.0M
• IPI Command Cable, 2.0M
• IPI Command Cable, 0.45M
• IPI Command Cable, 1.0M
• IPI "W" Command Cable (not currently in use)

370-1372

Prestoserve NFS Accelerator

Technical Volume II

BD-17

PARTS BREAKDOWN

12/90

Tape Controller

PART #

DESCRIPTION

370-0502
501-0526
370-1011
370-1026
370-1061
370-1067
370-1235

Ciprico Tapemaster Multibus 1/2" Tape Controller
Sun 256Kb Multibus Memory & 1/4" Tape Controller
Sysgen SC4000 SCSI Tape Controller
Archive Stand Alone Controller
Emulex MT02 SCSI Tape Controller
Xylogics 472 Multibus 1/2" Tape Controller
Emulex MT02 SCSI Tape Controller

501-1155
501-1187
370-1067
530-1165
530-1209
530-1691

Xylogics 472 1/2" Tape Controller Assembly, 9U VMEbus
• 9U VME Adapter Assembly for Xylogics 472
• Xylogics 472 Multibus 1/2" Tape Controller
• Tape Command Cable, Xylogics 472 to 9U Backpanel
External Tape Command Cable, 2.0M
External Tape Command Cable, 5.5M

501-1249
501-1187
370-0502
530-1165
530-1209

Ciprico Tapemaster 1/2" Tape Controller
• 9U VME Adapter Assembly for Ciprico Tapemaster
• Ciprico Tapemaster Multibus 1/2" Tape Controller
• Tape Command Cable, Ciprico Tapemaster to 9U Backpanel
External Tape Command Cable, 2.0M
External Tape Command Cable, 6.0M

530-1691

8D-18

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Communication
Ethernet and FOOl
PART #

DESCRIPTION

370-1111
370-1180
370-1181

3Com 3C501 ATbus Etherlink I Controller
3Com 3C503 ATbus Etherlink II Controller
3Com 3C523 Microchannel Etherlink/MC Controller

370-0288
370-8012
370-8012
501-1004
501-1450
501-8027

3Com 3C400 Multibus Ethernet Controller
Fibercom 027-1 00G6 Fiberoptic Ethernet Controller
Fibercom 7501-01 Fiberoptic Ethernet Controller
Sun-2 Multibus Ethernet Controller
SBus Ethernet Controller
Sun-3/E SCSI/Ethernet Controller

501-1153
501-1004
530-1173

Sun-2 Ethernet Controller Assembly
Sun-2 Multibus Ethernet Controller
• Ethernet Cable, Ethernet Controller to Backpanel

•

501-1584
501-8027
530-1607

Sun-3/E Ethernet Controller Assembly
Sun-3/E Ethernet Controller
• Ethernet Cable, Ethernet Controller to Backpanel

501-1276
537-1000

•

Sunlight FOOl
• Fiber Optic Cable, 15M

Technical Volume II

BD-19

PARTS BREAKDOWN

12/90

Communication
Multibus ALM and SCP
PART #

DESCRIPTION

370..:1039
370-1046
370-1047

Systech MTI-800 Multi-Channel Communication Board Set
• Systech MTI-800 USART Board
• MTI-800/1600 Controller Board

370-1040
370-1047
370-1048

Systech MTI-1600 Multi-Channel Communication Board Set
• MTI-800/1600 Controller Board
• Systech MTI-800 USART Board

370-1096
370-1099
811-1100

Systech MTI-1650B Multi-Channel Communication Board Set
MTI-850/1650 Controller Board
• Systech MTI-1650A USART Panel

•

370-1097
370-1099
370-1100

Systech MTI-1650B Multi-Channel Communication Board Set
• MTI-850/1650 Controller Board
• Systech MTI-1650B USART Board

370-1098
370-1099
370-1102

Systech MTI-85dB Multi-Channel Communication Board Set
• MTI-850/1650 Controller Board
• Systech MTI-850B USART Board

370-1049
540-1309
540-1281

Systech DCP-8804 Communications Processor
• RS-449 Loopback Test Plug
• RS-232 Loopback Test Plug

BO-20

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Communication
VMEbus ALM and SCP
PART #

DESCRIPTION

501-1157
370-1040
370-1047
370-1048
370-1097
370-1099
370-1100
530-1251
530-1252
530-1255
540-1281
540-1558

16-Channel Asychronous Line Multiplexer (ALM)
• Systech MTI-1600 Board Set
• Systech MTI-1600 Controller Board
• Systech MTI-1600 USART Board
• Systech MTI-1650B Board Set
• Systech MTI-1650B Controller Board
• Systech MTI-1650B USART Board
• Cable, Systech Controller to Systech USART
• Cable, Systech MTI-1600/1650B to Backpanel

501-1165
370-1096
370-1099
811-1100
530-1276
530-1295
540-1281
540-1558

Rackmounted 16-Channel Asychronous Line Multiplexer(ALM)
• Systech MTI-1650A Board Set
• Systech MTI-1650B Controller Board
• 16-Channel USART Rackmount Panel
• RS-232 Cable, Systech MTI-1650A to Backpanel
• DC Power Cable, ALM to USART Panel
• RS-232 Loopback Test Plug (obsolete)
• RS-232 Loopback Test Plug

501-1158
370-1049
530-1178
530-1179
530-1180
530-1181
540-1309
540-1281

SunLink Serial Communications Processor Assembly (SCP)
• Systech DCP-8804 Communications Processor
• RS-232 Cable, Long
• RS-232 Cable, Short
• RS-449 Cable, Long
• RS-449 Cable, Short
• RS-449 Loopback Test Plug
• RS-232 Loopback Test Plug

• DC Power Cable
• RS-232 Loopback Test Plug (obsolete)
• RS-232 Loopback Test Plug

Technical Volume II

BO-21

12/90

PARTS BREAKDOWN

Communication
ALM-2
PART #

MCP

HSI Channel Adapter
DESCRIPTION

501-1203
340-1569
340-1587
340-1914
340-1915
530-1334
540-1526
540-1558
540-1560

16 Channel Asychronous Line Multiplexer-2 (ALM-2)
• Rack Mounting Bracket
• Wall Mounting Bracket
• Rack Mounting Bracket, Short, 56" Rack
• Rack Mounting Bracket, Long, 56" Rack
• Cable, ALM-2 to DCA
• DCA Assembly
• RS-232 Loopback Test Plug
• Parallel Port Loopback Test Plug

501-1221
540-1558
540-1559

SunLink Multiprotocol Communications Processor (MCP)
• RS-232 Loopback Test Plug
• RS-449 Loopback Test Plug

501-1338
530-1425
530-1426
530-1430

SunLink High-Speed Serial Interface (HSI)
• V.35 Cable, HSI to DSU
• V.35 Loopback Test Plug
• RS-449 Loopback Test Plug

370-1128
501-1460
530-1134
370-1135
370-1136
370-1129
370-1130
370-1131
370-1132
530-1364

SunLink Channel Adapter (obsolete)
SunLink Channel Adapter

BD-22

•
•
•
•
•
•
•
•

Loopback Test Cable
Bus Terminator
Tag Terminator
Tag In & Bus In Cable, 8'
Tag Out & Bus Out Cable, 8'
Tag Out & Bus Out Cable, 5' (obsolete)
Tag In & Bus In Cable, 5' (obsolete)
RS-232 Diagnostic Port Cable, 20'

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Communication
SBus
PART #

DESCRIPTION

501-1450

SBus Ethernet Controller

501-1511
540-2007
540-1558
540-1701
530-1685

SBus Serial Parallel Controller
• 8-Channel Interface Panel
• RS-232 Loopback Test Plug. 25-Pin
• SBus Card Loopback Test Plug. 96-Pin High-Density
• Interface Cable. SBus Card to Interface Panel. 2.0M

501-1557

SBus FOOl

501-1725
530-1685
370-1381
370-1383
540-2030

SBus High Speed Serial Interface (HSI)
• Interface Cable. SBus Card to Interface Panel. 2.0M
• SBus Card Loopback Test Plug. 96-Pin High-Density
• RS-530 Loopback Test Plug. 25-Pin
• 4-Channel Interface Panel

501-2140
530-1680
530-1683
530-1694
370-1365

SBus Printer Board
• Parallel Port Cable. 28-Pin High-Density to Centronics
• Loopback Test Cable. Parallel Port to Video Port
• Test Cable. Video Port to Video Port
• Video Port Cable. Video Port to SPARCprinter

Technical Volume II

BD-23

12/90

PARTS BREAKDOWN

SCSI Host Adapter
Boards and Cables
PART #

DESCRIPTION

501-1006
501-1045
501-1120
501-1236
501-8027
501-1759
501-1850

Sun-2 Multibus SCSI Host Adapter
Sun-2 VMEbus SCSI Host Adapter
Sun-3 VMEbus SCSI Host Adapter (obsolete)
Sun-3 VMEbus SCSI Host Adapter
Sun-3/E VMEbus SCSI Host Adapter
SBus SCSI Host Adapter. FCC-ANCCI-1
SBus SCSI Host Adapter. FCC-BNCCI-2

530-1185
530-1186
530-1249
530-1250
530-1334
530-1365

External
External
External
External
External
External

530-1435
530-1593

External SCSI Cable. 50-Pin SCSI-2 to DD-50SA. 200M
External SCSI Cable. 50-Pin SCSI-2 to DD-50SA. 100M

530-1434
530-1508

External SCSI Cable. 50-Pin SCSI-2 to 50-Pin SCSI-2. 45 cm
External SCSI Cable. 50-Pin SCSI-2 to 50-Pin SCSI-2. 80 cm

530-1501
530-1502
530-1503
530-1568

External
External
External
External

BD-24

SCSI
SCSI
SCSI
SCSI
SCSI
SCSI

SCSI
SCSI
SCSI
SCSI

Cable.
Cable.
Cable.
Cable.
Cable.
Cable.

Cable.
Cable.
Cable.
Cable.

DD-50SA
DD-50SA
DD-50SA
DD-50SA
DD-50SA
DD-50SA

to
to
to
to
to
to

DD-50SA.
DD-50SA.
DD-50SA,
DD-50SA.
DD-50SA.
DD-50SA,

Ribbon. 100M (obs)
Ribbon. 500M (obs)
100M
300M
205M
41 cm

DD-50SA to Centronics. 200M
Centronics to Centronics. 105M
50-Pin SCSI-2 to Centronics. 200M
DD-50SA to Centronics. 400M

Field Engineer Handbook

12/90

PARTS BREAKDOWN

SCSI Host Adapter
Assemblies
PART #

DESCRIPTION

501-1147
501-1045
501-1079

Sun-2/50 SCSI Host Adapter Assembly, External SCSI
• Sun-2 VMEbus SCSI Host Adapter
• Sun-2/50 Omb Memory Expansion Board

501-1149
501-1045
270-1059

Sun-2 SCSI Host Adapter Assembly, Internal SCSI
• Sun-2 SCSI Host Adapter
• VME 3x2 Adapter FAB with P2 Rows A&C

501-1138
501-1045
270-1138

Sun-2 SCSI Host Adapter Assembly, External SCSI
• Sun-2 SCSI Host Adapter
• VME 3x2 Adapter FAB without P2 Rows A&C

501-1167
501-1045
270-1059

Sun-2 SCSI Host Adapter Assembly, External SCSI
• Sun-2 SCSI Host Adapter
• VME 3x2 Adapter FAB with P2 Rows A&C

501-1170
501-1236
270-1059

Sun-3 SCSI Host Adapter Assembly, Internal SCSI
• Sun-3 SCSI Host Adapter
• VME 3x2 Adapter FAB with P2 Rows A&C

501-1172
501-1045
501-1121

Sun-3/75 SCSI Host Adapter Assembly, External SCSI
• Sun-2 VMEbus SCSI Host Adapter
• Sun-3/75 OMB Memory Expansion Board

501-1217
501-1236
270-1138

Sun-3 SCSI Host Adapter Assembly, External SCSI
• Sun-3 SCSI Host Adapter
• VME 3x2 Adapter FAB without P2 Rows A&C

Technical Volume II

BD-25

12/90

PARTS BREAKDOWN

Backplane
PART #

DESCRIPTION

340-0332
340-0644
501-1049
501-1050
501-1090
501-1150

7-Slot Multibus Backplane & Cardcage Assembly
15-Slot Multibus Backplane & Cardcage Assembly
9-Slot Multibus Backplane, Sun-2/120
15-Slot Multibus Backplane, Sun-2/170
9-Slot Multibus Backplane, Sun-2/120 (obsolete)
15-Slot Multibus Backplane, Sun-2/170 (obsolete)

501-1042
501-1085
501-1092
501-1093
501-1109
501-1117
501-1127
501-1128
501-1277
501-1354
501-1439
501-1498
501-1597
501-1598
501-1832

2-Slol VMEbus Backplane, Sun-2/50
12-Slot VMEbus Backplane, Sun-2/130/160
12-Slot VMEbus Backplane, (obsolete)
2-Slot VMEbus Backplane, Sun-3/75
l-Slot Backplane, Sun-3/50
12-Slot VMEbus Backplane, Pressfit
3-Slot VMEbus Backplane, Pressfit
6-Slot VMEbus Backplane, Pressfit
l-Slot Backplane, Pressfit, Sun-3/50/60
5-Slot VMEbus Backplane, Pressfit
12-Slot Backplane. 9 VMEbus Slots, Press fit (obsolete)
16-Slot Backplane, 13 VMEbus Slots, Pressfit (obsolete)
16-Slot Backplane, 13 VMEbus Slots, Pressfit, Fused
12-Slot Backplane, 9 VMEbus Slots, Pressfit
12-Slot Backplane, 9 VMEbus Slots, Pressfit with cutout

BD-26

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Miscellaneous

PART #

DESCRIPTION

370-1021
370-1029
501-1105
501-1146
501-1154
501-1191
501-1220
501-1269
501-1384
501-1387
501-1454
501-1666
540-1108
540-1250

Sky Floating Point Processor, Multibus
Sky Floating Point Processor, VMEbus
Floating Point Accelerator
Floating Point Accelerator PI~s
VMEbus to Multibus Adapter Assembly, Blank Backpanel
VME 3x2 Adapter Assembly, without P2 A&C, Option 160B
VME 3x2 Adapter Assembly, without P2 A&C
VME 3x2 Adapter Assembly, with P2 A&C, Option 160A
Sun 4100 FPU2
Sun 4200 FPU2
Sun-4/60 SBus FPU
VME 3x2 Adapter Assembly, with P2 A&C
VME 3x2 Adapter Assembly (obsolete)
VMEbus to Multibus Adapter Assembly (obsolete)

501-1125
501-1214
501-1196
370-1125

SunlPC without 80287
SunlPC with 80287
• Parallel Port Loopback Test Plug
• Floppy Drive Cable, SunlPC to Floppy Drive

501-1148
370-1029
501-1079

Sky Floating Point Processor Assembly, VMEbus
• Sky Floating Point Processsor
• Sun-2/50 Omb Memory Expansion Board

501-1151
370-1029
501-1059

Sky Floating Point Processor Assembly, VMEbus
• Sky Floating Point Processsor
• VME 3x2 Adapter Assembly

Technical Volume II

BD-27

PARTS BREAKDOWN

MONITOR

12/90

PARTS BREAKDOWN

Monitor
Video Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
14-inch Seiko Color ........................
15-inch Hitachi Color .......................
15-inch Sam po Monochrome ECL . . . . . . . . . . . ..
16-inch Sony Color . . . . . . . . . . . . . . . . . . . . . . . ..
16-inch Sony Color ........................
17-inch Zenith Greyscale . . . . . . . . . . . . . . . . . . ..
17-inch Greyscale . . . . . . . . . . . . . . . . . . . . . . . . ..
19-inch Color .............................
19-inch Sony Color . . . . . . . . . . . . . . . . . . . . . . . ..
19-inch Sony Color . . . . . . . . . . . . . . . . . . . . . . . ..
19-inch Greyscale .........................
19-inch Greyscale . . . . . . . . . . . . . . . . . . . . . . . . ..
19-inch Greyscale with OCLI .................
19-inch Monochrome ECL . . . . . . . . . . . . . . . . . ..
19-inch Monochrome ECL with OCLI . . . . . . . . . ..
19-inch High Resolution ECL . . . . . . . . . . . . . . . ..
19-inch High Resolution ECL with OCLI ........
21-inch Toshiba Color ......................

Field Engineer Handbook - Technical Volume II

3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

12/90

PARTS BREAKDOWN

This page intentionally left blank.

MON-2

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Video Cables

PART #

DESCRIPTION

530-0492
530-1138
530-1307
530-1362
530-1415
530-1440
530-1446
530-1509

Color
Color
Color
Color
Color
Color
Color
Color

Video
Video
Video
Video
Video
Video
Video
Video

Cable, 4.6M, 1xBNC to 1xBNC
Cable, 4.6M, 4xBNC to 4xBNC
Cable, 4.6M, 4xBNC to 4xBNC
Cable, 1.2M, 4xBNC to 4xBNC
Cable, 50 em, 4xBNC to 4xBNC
Cable, 1.2M, OB 13W3 to OB 13W3
Adapter Cable, 4xBNC to OB13W3
Cable, 4.6M, OB13W3 to OB13W3

530-1308
530-1363
530-1511

Greyscale Video Cable, 4.6M, 2xBNC to 2xBNC
Greyscale Video Cable, 1.2M, 2xBNC to 2xBNC
Greyscale Video Adapter Cable, 2xBNC to OB13W3

530-1041
530-1109
530-1125
530-1133
530-1242
530-1336
530-1359

TTL
ECl
TTL
ECl
ECl
ECl
ECl

530-1366
530-1383
530-1621

Color Video & Keyboard Cable, OB21W3 to 4xBNC (386i)
Monochrome Video & Keyboard Cable, OB21W3 to OB9 (386i)
Color Video & Keyboard Cable, OB21W3 to OB13W3 (386i)

Monochrome
Monochrome
Monochrome
Monochrome
Monochrome
Monochrome
Monochrome

Technical Volume II

Video
Video
Video
Video
Video
Video
Video

Cable,
Cable,
Cable,
Cable,
Cable,
Cable,
Cable,

OB-9 to OB-9 (Sun-2/150U)
75 em, OB-9 to OB-9
4.6M, OB-9 to OB-9
4.6M, OB-9 to OB-9
75 em, OB-9 to OB-9
4.6M, OB-9 to OB-9
1.2M, OB-9 to OB-9

MON-3

PARTS BREAKDOWN

12/90

14-inch Seiko Color
1024 x 768 Pixel Resolution
53.6KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

360-1033
530-1370

115V Monitor, FCC-A, 4xBNC
Power Cord, IEC 320/CEE 22 to NEMA 5-15, USA

360-1034
530-1583
530-1410
530-1411

240V Monitor, FCC-A, 4xBNC
Power Cord, IEC 320/CEE 22 to SEV 1011-24507, Swis
Power Cord, IEC 320/CEE 22 to CEE 7-VII, Europe
Power Cord, IEC 320/CEE 22 to BS1363, UK

360-1035
530-1370

115V Monitor, FCC-B, 4xBNC (obsolete)
Power Cord, IEC 320/CEE 22 to NEMA 5-15, USA

360-1036
530-1583
530-1410
530-1411

240V Monitor, FCC-B, 4xBNC (obsolete)
Power Cord, IEC 320/CEE 22 to SEV 1011-24507, Swiss
Power Cord, IEC 320/CEE 22 to CEE 7-VII, Europe
Power Cord, IEC 320/CEE 22 to BS1363, UK

MON-4

Field Engineer Handbook

PARTS BREAKDOWN

12/90

15-inch Hitachi Color
1152 x 900 Pixel Resolution
62KHz Horizontal Scan Frequency
66Hz Refresh Rate
PART #

360-1015
180-1125
180-1097

DESCRIPTION

115V1240V Monitor, 4xBNC
Power Cord, IEC 320/CEE 22 to pigtail
Power Cord, IEC 320/CEE 22 to NEMA 5-15

Technical Volume II

MON-5

PARTS BREAKDOWN

12/90

15-inch Sampo Monochrome Eel
1024 x 768 Pixel Resolution
63.96KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

360-1026
530-1372,

115V Monitor, DB9
Power Cord, IEC 320/CEE 22 to NEMA 5-15, USA

365-1038
530-1583
530-1410
530-1411

240V Monitor, DB9
Power Cord, IEC 320/CEE 22 to SEV 1011-24507, Swiss
Power Cord, IEC 320/CEE 22 to CEE 7-VII, Europe
Power Cord, IEC 320/CEE 22 to BS1363, UK

MON-6

Field Engineer Handbook

12/90

PARTS BREAKDOWN

16-inch Sony Color
1152 x 900 Pixel Resolution
61.8KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1020
150-1225
180-1146
180-1097

115V Monitor, 4xBNC
Fuse,4A
Power Cord, IEC 320/CEE 22 to NEMA 5-15
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1022
150-1226
180-1125

240V Monitor, 4xBNC
Fuse,3.15A
Power Cord, IEC 320/CEE 22 to pigtail

365-1063 115V Monitor, DB13W3
150-1225 Fuse,4A
180-1146 Power Cord, IEC 320/CEE 22 to NEMA 5-15
365-1064
150-1226
180-1125

240V Monitor, DB13W3
Fuse, 3.15A
Power Cord, IEC 320/CEE 22 to pigtail

365-1079
150-1225
180-1146

115V Monitor, DB13W3, VCCI-1
Fuse,4A
Power Cord, IEC 320/CEE 22 ro NEMA 5-15

365-1080
150-1226

240V Monitor, DB13W3, VCCI-1
Fuse,3.15A

365-1092
150-1225
180-1146

115V Monitor, DB13W3, FCC-BNCCI-2
Fuse,4A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1093
150-1226

240V Monitor, DB13W3, FCC-BNCCI-2
Fuse,3.15A

Technical Volume II

MON-7

PARTS BREAKDOWN

12/90

16-inch Sony Color
17-inch Overscan
1152 x 900 Pixel Resolution
61.8KHz Horizontal Scan Frequency
66Hz or 76Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1096

115V/240V Monitor, DB13W3, FCC-ANCCI-1 (not used)

365-1113

115V/240V Monitor, DB13W3, FCC-BNCCI-2

365-1130

115V/240V Monitor, DB13W3, FCC-BNCCI-2, VLF

365-1107

115V/240V OEM Monitor, DB13W3, FCC-BNCCI-2

Notes
1. The overscan mode is not supported at 66Hz vertical refresh.
2. Monitor sense code information is not interpreted properly by older
CG6 Color Frame Buffers. Video is not displayed upon power-up until
the video cable is removed and reconnected. The following. board
revisions are affected.
P4 CG6, 501-1505-03 and below
P4 CG6, 501-1532-09 and below
SBus CG6, 501-1481-04 and below
SBus CG6 501-1645-03 and below.

MON-8

Field Engineer Handbook

PARTS BREAKDOWN

12/90

17-inch Zenith Greyscale
1152 x 900 Pixel Resolution
62KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1055

90-240V Monitor, DB13W3

365-1094

90-240V Monitor, DB13W3, FCC-BNCCI-2

365-1062

90-240V Monitor, DB13W3, GCLI

Technical Volume II

MON-9

PARTS BREAKDOWN

12/90

17-inch Greyscale
16-inch Underscan
1152 x 900 Pixel Resolution
71.7KHz & 70.8KHz Horizontal Scan Frequency
76Hz & 84Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1100

115V/240V Monitor, DB13W3, FCC-BNCCI-2

365-1109

115V/240V OEM Monitor, DB13W3, FCC-BNCCI-2

MON-10

Field Engineer Handbook

12/90

PARTS BREAKDOWN

19-inch Color
1152 x 900 Pixel Resolution
62KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

540-1094
140-1022
180-1097
360-1008

115V Monitor. 4xBNC. Metal Base
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to NEMA 5-15
19" Monitor

365-1000
140-1022
180-1097
180-1146

115V Monitor. 4xBNC. 395x535 mm Base
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to NEMA 5-15
Power Cord. IEC 320/CEE 22 to NEMA 5-15

365-1006
150-1034
150-1051
180-1125

240V Monitor. 4xBNC. 395x535 mm Base
Fuse.2A
Fusecarrier
Power Cord. IEC 320/CEE 22 to pigtail

365-1056
140-1022
180-1146

115V Monitor. 4xBNC. 409x409 mm Base
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to NEMA 5-15

365-1054
150-1034
150-1051
180-1125

240V Monitor. 4xBNC. 409x409 mm Base
Fuse.2A
Fusecarrier
Power Cord. IEC 320/CEE 22 to pigtail

365-1073

115V/240V Monitor. DB13W3. VCCI-1. 409x409 mm Base

Technical Volume II

MON-11

PARTS BREAKDOWN

12/90

19-inch Sony Color
1152 x 900 Pixel Resolution
62KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1038
150-1225
180-1146

115V Monitor, 4xBNC
Fuse,4A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1039
150-1226
180-1125

240V Monitor, 4xBNC
Fuse, 3.15A
Power Cord, IEC 320/CEE 22 to pigtail

365-1065
150-1225

115V Monitor, DB13W3
Fuse,4A

365-1066
150-1226

240V Monitor, DB13W3
Fuse,3.15A

365-1081
150-1225

115V Monitor, DB13W3, VCCI-1
Fuse,4A

365-1082
150-1226

240V Monitor, DB13W3, VCCI-1
Fuse,3.15A

MON-12

Field Engineer Handbook

12/90

PARTS BREAKDOWN

19-inch Sony Color
20-inch Overscan
1152 x 900 Pixel Resolution
61.8KHz Horizontal Scan Frequency
66Hz or 76Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1095

115V/240V Monitor, DB13W3, FCC-ANCCI-1

365-1106

115V/240V OEM Monitor, DB13W3, FCC-ANCCI-1

365-1112

115V/240V Monitor, DB13W3, FCC-BNCCI-2, VLF

365-1114

115V/240V OEM Monitor, DB13W3, FCC-BNCCI-2, VLF

Notes
1. The overscan mode is not supported at 66Hz vertical refresh.
2. Monitor sense code information is not interpreted properly by older
CG6 Color Frame Buffers. Video is not displayed upon power-up until
the video cable is removed and reconnected. The following board
revisions are affected.
P4 CG6, 501-1505-03 and below
P4 CG6, 501-1532-09 and below
SBus CG6, 501-1481-04 and below
SBus CG6 501-1645-03 and below.

Technical Volume II

MON-13

PARTS BREAKDOWN

12/90

19-inch Greyscale
1152 x 900 Pixel Resolution
62KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

540-1514
140-1022
180-1097
180-1146
360-1012
360-1021

115V Monitor, 2xBNC, 395x535 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE22 to NEMA 5-15
Power Cord, IEC 320/CEE 22 to NEMA 5-15
19-inch Monitor
19-inch Monitor

540-1567
150-1051
150-1215
180-1125

240V Monitor, 2xBNC, 395x535 mm Base
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

365-1010
140-1022
180-1097
180-1146

115V Monitor, 2xBNC, 395x535 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15, USA
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1009
150-1051
150-1215

240V Monitor, 2xBNC, 395x535 mm Base
Fusecarrier
Fuse, 1.6A

180-1125
365-1053
140-1022
180-1146

Power Cord, IEC 320/CEE 22 to pigtail
115V Monitor, 2xBNC, 409x409 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1046
150-1051
150-1215
180-1125

240V Monitor, 2xBNC, 409x409 mm Base
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

365-1071

115V/240V Monitor, DB13W3, VCCI-l, 409x409 mm Base

MON-14

Field Engineer Handbook

12/90

PARTS BREAKDOWN

19-inch Greyscale
20-inch Overscan
1152 x 900 Pixel Resolution
71.7KHz Horizontal Scan Frequency
76Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1099

115V/240V Monitor, DB13W3, FCC-BNCCI-2

365-1108

115V/240V OEM Monitor, DB13W3, FCC-BNCCI-2

Technical Volume II

MON-15

PARTS BREAKDOWN

12/90

19-inch Greyscalewith

oell

1152 x 900 Pixel Resolution

62KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1008
150-1051
150-1215
180-1125

240V Monitor. 2xBNC. 395x535 mm Base
Fusecarrier
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to pigtail

365-1052
150-1051
150-1215
180-1125

240V Monitor. 2xBNC. 409x409 mm Base
Fusecarrier
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to pigtail

MON-16

Field Engineer Handbook

12/90

PARTS BREAKDOWN

19-inch Monochrome Eel
1152 x 900 Pixel Resolution
62KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

540-1062
140-1022
180-1097

115V Monitor, OB9, without Base (3/50 dimple top)
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

540-1562
150-1051
150-1215
180-1125

240V Monitor, OB9, 395x535 mm Base
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

540-1240
140-1022
180-1097

115V Monitor, OB9, 395x535 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1016
140-1022
180-1097
180-1146

115V Monitor, OB9, 395x535 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1014
150-1051
150-1215
180-1125

240V Monitor, OB9, 395x535 mm Base
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

365-1051
140-1022
180-1097
180-1146

115V Monitor, OB9, 409x409 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1043
150-1051
150-1215
180-1125

240V Monitor, OB9, 409x409 mm Base
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

365-1086

115V/240V Monitor, OB9, VCCI-1, 409x409 mm BaSe

Technical Volume II

MON-17

12/90

PARTS BREAKDOWN

19-inch Monochrome ECl with OCll
1152 x 900 Pixel Resolution
62KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

540-1358
140-1022
180-1097
360-1013

115V Monitor. OB9. without Base
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to NEMA 5-15
19-inch Monitor

540-1565
150-1051
150-1215
180-1125

240V Monitor. OB9. 395x535 mm Base
Fusecarrier
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to pigtail

540-1357
140-1022
180-1097
360-1013

115V Monitor. OB9. 395x535 mm Base
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to NEMA 5-15
19-inch Monitor

365-1013
140-1022
180-1097
180-1146

115V Monitor. OB9. 395x535 mm Base
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to NEMA 5-15
Power Cord. IEC 320/CEE 22 to NEMA 5-15

365-1011
150-1051
150-1215
180-1125

240V Monitor. OB9. 395x535 mm Base
Fusecarrier
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to pigtail

365-1044
140-1022
180-1097
180-1146

115V Monitor, OB9. 409x409 mm Base
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to NEMA 5-15
Power Cord. IEC 320/CEE 22 to NEMA 5-15

365-1045
150-1051
150-1215
180-1125

240V Monitor. OB9. 409x409 mm Base
Fusecarrier
Fuse. 1.6A
Power Cord. IEC 320/CEE 22 to pigtail

365-1087

115V/240V Monitor. OB9. VCCI-1. 409x409 mm Base

MON-18

Field Engineer Handbook

12/90

PARTS BREAKDOWN

19-inch High Resolution Eel
1600 x 1280 Pixel Resolution
89KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

540-1427
140-1022
180-1097
360-1014

115V Monitor, OB9, 395x535 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15
19-inch Monitor

540-1571
150-1034
150-1051
180-1125

240V Monitor, OB9, 395x535 mm Base
Fuse,2A
Fusecarrier
Power Cord, IEC 320/CEE 22 to pigtail

365-1005
140-1022
180-1097
180-1146

115V Monitor, OB9, 395x535 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1007
150-1034
150-1051
180-1125

240V Monitor, OB9, 395x535 mm Base
Fuse,2A
Fusecarrier
Power Cord, IEC 320/CEE 22 to pigtail

365-1047
140-1022
180-1146

115V Monitor, OB9, 409x409 mm Base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1050
150-1051
150-1215
180-1125

240V Monitor, OB9, 409x409 mm Base
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

365-1123
140-1022
180-1146

115V Monitor, OB9, 409x409 mm Base, VCCI-1
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1128
150-1051
150-1215
180-1125

240V Monitor, OB9, 409x409 mm Base, VCCI-1
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

Technical Volume II

MON-19

12/90

PARTS BREAKDOWN

19-inch High Resolution ECl with OCll
1600 x 1280 Pixel Resolution
89KHz Horizontal Scan Frequency
66Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1004
140-1022
180-1097
180-1146

115V Monitor, 089, 395x535 mm base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15, USA
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1003
150-1051
150-1215
180-1125

240V Monitor, 089, 395x535 mm base
Fusecarrier
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to pigtail

365-1048
140-1022
180-1146

115V Monitor, 089, 409x409 mm base
Fuse, 1.6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

365-1049
150-1051
150-1215
180-1125

240V Monitor, 089, 409x409 mm base
Fusecarrier
Fuse, 1,6A
Power Cord, IEC 320/CEE 22 to NEMA 5-15

MON-20

Field Engineer Handbook

12/90

PARTS BREAKDOWN

21-inch Toshiba Color
20-inch Underscan
1280 x 1024 Pixel Resolution
81.13KHz Horizontal Scan Frequency
76Hz Vertical Refresh Rate
PART #

DESCRIPTION

365-1068

115V/240V Monitor, DB13W3, FCC-ANCCI-1

365-1110

115V/240V OEM Monitor, DB13W3, FCC-ANCCI-1

Technical Volume II

MON-21

PARTS BREAKDOWN

KEYBOARD/MOUSE

PARTS BREAKDOWN

12/90

Keyboard/Mouse
Type-3 Keyboard ..........................
Type-3 Mouse. . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Type-4 Keyboard ..........................
Type-4 Mouse. . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Type 101A Keyboard .......................

Field Engineer Handbook - Technical Volume II

3
3
4
4
5

12/90

PARTS BREAKDOWN

This page intentionally left blank.

KY/MS-2

Field Engineer Handbook

PARTS BREAKDOWN

12/90

Type-3 Keyboard
PART #

370-1063
370-1095
530-1526

DESCRIPTION

Type-3 Keyboard, DB-15 (obsolete)
Type-3 Keyboard, DB-15
Type-3 Keyboard Adapter Cable, DB-15 to Mini-Din

Type-3 Mouse
PART #

DESCRIPTION

370-1058
370-1091

M3 Mouse & Pad, RJ11 (obsolete)
M3 Mouse & Pad, RJ11 (obsolete)

365-1042
370-1169
370-1171
370-1215
370-1368

M4 Mouse & Pad,
• M4 Mouse, 200
• M4 Mouse Pad,
• M4 Mouse Pad,
• M4 Mouse Pad,

Technical Volume II

RJ11
CPI, RJ11
200 CPI, 0.062", 228.6 x 196.9 mm (obs)
200 CPI, 0.032", 228.6 x 196.9 mm (obs)
200 CPI. 0.032", 177.8 x 196.9 mm

KY/MS-3

PARTS BREAKDOWN

12/90

Type-4 Keyboard
PART #

DESCRIPTION

320-1002
320-1005
320-1006
320-1007
320-1008
320-1009
320-1010
320-1011
320-1012
320-1013
320-1014
320-1015
320-1016
320-1017
320-1018

Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4
Type-4

Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.
Keyboard.

Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.
Mini-Din.

US (obsolete)
US
German
Swiss German
Belgium & France
UK
Swiss French
Netherlands
Sweden & Denmark
Denmark
Norway
Italy
Spanish
Portugal
French Canadian

530-1442
530-1443

Keyboard Cable. Mini-Din to Mini Din. 2.0M
Keyboard Cable. Mini-Din to Mini Din. 4.6M

530-1478
530-1479

Keyboard Cable. DB-15 to Mini Din. 2.0M
Keyboard Cable. DB-15 to Mini Din. 4.6M

530-1366
530-1383
530-1621

Color Video & Keyboard Cable. DB21W3 to 4xBNC (Sun386i)
Monochrome Video & Keyboard Cable. DB21W3 to DB9 (Sun386i)
Color Video & Keyboard Cable. DB21W3 to DB13W3 (Sun386i)

Type-4Mouse
PART #

370-1161
365-1059
370-1170
370-1215
370-1368

KY/MS-4

DESCRIPTION

M4 200 CPI Mouse and Pad. Mini-Din (unreleased part. obsolete)
M4 200 CPI Mouse and Pad. Mini-Din
• M4 200 CPI Mouse, Mini-Din
• M4 Mouse Pad, 200 CPl. 0.032". 228.6 x 196.9 mm (obsolete)
• M4 Mouse Pad, 200 CPI, 0.032", 177.8 x 196.9 mm

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Type 101A Keyboard
PART #

DESCRIPTION

320-1002

Type 101A Keyboard, Mini-Din

530-1442
530-1443

Keyboard Cable, Mini-Din to Mini Din, 2,OM
Keyboard Cable, Mini-Din to Mini Din, 4.6M

530-1478
530-1479

Keyboard Cable, D8-15 to Mini Din, 2.0M
Keyboard Cable, D8-15 to Mini Din, 4.6M

Technical Volume II

KY/MS-5

PARTS BREAKDOWN

MISCELLANEOUS

PARTS BREAKDOWN

12/90

Miscellaneous
AC Power Cords . . . . . . . . . . . . . . . . . . . . . . . . . ..
Ethernet Parts ... . . . . . . . . . . . . . . . . . . . . . . . . ..
Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Recommended Service Tools . . . . . . . . . . . . . . . ..

Field Engineer Handbook - Technical Volume \I

3
4
5
8

PARTS BREAKDOWN

12/90

This page intentionally left blank.

MISC-2

Field Engineer Handbook

12/90

PARTS BREAKDOWN

AC Power Cords
PART #

180-1097
180-1125
180-1146
180-1176
180-1177
180-1177
180-1177
180-1178
180-1178
180-1179
180-1234
180-1235
180-1236
530-1370
530-1372
530-1410
530-1411
530-1583
530-1657
530-1663
530-1663
530-1664
530-1664
530-1665
530-1671

FEMALE TO MALE CONNECTOR DESCRIPTION

IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
AS 3109.1-1987
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22
IEC 320/CEE 22

Technical Volume II

to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to

NEMA 5-15
pigtail
NEMA 5-15
BS1363
CEE 7-VII
CEE 7-VII
CEE 7-VII
SEV 1011.1959
SEV 1011.1959
NEMA 5-15
DHPR 1962
CEI 23-16/V11
SAA AS 3112
NEMA 5-15
NEMA 5-15
CEE 7-VII
BS1363
SEV 1011-24507
NEMA 5-15
CEE 7-VII
CEE 7-VII
SEV1011-24507
SEV1011-24507
107/10-1973
BS1363

COUNTRY

USA
USA
United Kingdom
French
German
Swedish
Swiss/German
Swiss/French
USA
Denmark
Italy
Australia/New Zealand
USA
USA
Europe
UK
Swiss
US
French
German
Swiss/French
Swiss/German
Swedish
United Kingdom

MISC-3

PARTS BREAKDOWN

12/90

Ethernet Parts
DESCRIPTION

ORDER NUMBER

PART NUMBER

3Com 3c400 Controller

370-0288

3Com 3c100 Transceiver

370-0331

N-series Connector
N-series Male Terminator

370-0549
ETR

370-0368

15-meter Ethernet Coax Cable (obs)

370-0363

15-meter Transceiver Drop Cable (obs)

370-0364

BNC Tap Block. 3Com 3C139A

370-1074

N-series Tap Block. 3Com 3C139

370-1073

Vampire Tap Block. AMP 228752-1
Ethernet Installation Kit, Vampire Tap Tool

370-1072
ETH-TAP-TOOL

370-1075

3Com 3C101/102 Transceiver (obs)

370-1071-01

3Com 3C106 Transceiver

370-1071-02

15-meter Transceiver Drop Cable

530-1241

15-meter Thin Ethernet Cable

TS-15M

530-1253

5-meter Thin Ethernet Cable

TS-5M

530-1280

15-meter Ethernet Coax Cable

ECX

530-1254

BNC Female to N-series Male

TA-M

130-1240
130-1241

BNC Male Terminator

TT-M

BNC "T" .F.M.F

TTC

130-1242

BNC Barrel. Double Female

TBC

130-1243

BNC Terminator. Female

TT-F

130-1244

BNC Female to N-series Female

TA-F

130-1245

Adapter Cable. 250 mm

530-1519

Adapter Cable. Sun-4/20. 2.0M

530-1696

If the customer uses the AMP type attachment. an N-series female

XXX-XXXX-XX

terminator (not available from Sun). is needed to terminate the coax
cable.

AMP
----- *'. * -------------IMale Endl <----Terminator

MISC-4

Field Engineer Handbook

12/90

PARTS BREAKDOWN

FUSES
FUSE
1116A

DESCRIPTION
2S0V 3AG

SIZE

SUN PART #

VENDOR

VENDOR
PART #

.2Sxl.2S"

140-1004-01

Littelfuse

1116A 2S0V 3AG
118A
2S0V FAST

.2Sxl.2S"
.2Sxl.2S"

140-1004-01

Bussman

312.062
AGC 1116

140-1 003-01

Littelfuse

312.12S

118A

2S0V FAST

.2Sxl.2S"

140-1 003-01

Bussman

AGC 118

112A

2S0V SlO-BlO

.2Sxl.2S"

140-1012-01

Littelfuse

313.S00

314A

12SV FAST

Submini

140-1024-01

Littelfuse

2SS.7S0

314A

12SV FAST

Submini

140-1024-01

Bussman

GFA 314
273 001

lA

12SV

Submini

140-1027-01

Littelfuse

lA

2S0V NORMAl-BlO

.2Sx1.2S"

140-8S00-01

Bussman

AGC-l

lA

2S0V NORMAl-BlO

.2Sx1.2S"

140-8S00-01

Littelfuse

314001

1.5A

125V

Submini

150-1162-01

Littelfuse

273 01.5

1.5A

12SV

Submini

150-1 383-01

Littelfuse

273 01.5

1.5A

2S0V

5X20mm

SOC

MT4-1.51

1.6A
1.6A

2S0V NORMAL BLOW
2S0V NORMAL BLOW

.25xl.25"
.25x1.25"

150-1208-01
140-1022-01
140-1022-01

Littelfuse
BEL

3AG1.6

31201.6

1.6A

250V NORMAL BLOW

.25xl.25"

140-1022-01

Power Dynamics

19340 1.6A

1.6A

250V NORMAL BLOW

.25xl.2S"

140-1022-01

Bussman

AGC 1.6A

1.6A

2S0V SLOW BlO

5X20mm

150-1215-01

Schurter

034.3119

1.6A

2S0V SlO-BlO

SX20mm

150-1215-01

Littelfuse

21801.6

2A

2S0V 3AG

.25xl.25"

140-1005-01

Littelfuse

312 002

2A

2S0V 3AG

.25xl.25"

140-1005-01

Bussman

AGC 2

2A

2SV

Submini

140-1028-01

Littelfuse

252002

2A

2S0V Slow Blow

5x20mm

140-1034-01

Bussman

GDC-2

2A

250V SlO-BlO

Sx20mm

140-1034-01

Littelfuse

218 002

2A

125V FAST

Submini

IS0-1174-01

Littelfuse

273 002

2A

250V FAST-ACT

.2Sxl.2S"

IS0-1191-01

MGC

MGC 0002

2A

250V FAST-ACT

.25xl.25"

150-1191-01

Littelfuse

312002

2.5A

2S0V SlO-BlO 3AG

.2Sxl.25"

140-1 000-01

Littelfuse

31302.S

2.5A

250V SLOW BLOW 3AG

.2Sx1.25"

140-1000-01

Bussman

MDA 2 1/2

2.5A

2S0V 3AG

.25xl.25"

140-1 008-01

Littelfuse

313003

2.SA

2S0V 3AG

.2Sxl.2S"

140-1 008-01

Bussman

MDA 2112

3A

2S0V SlO-BlO

.2Sxl.25"

1SO-1 034-01

Littelfuse

313003

3A

2S0V SLOW BLOW

.25xl.2S"

150-1 034-01

Bussman

MDA-3

3A

2S0V SlO-BlO

5x20mm

140-1002-01

Littelfuse

2183.15

3A

2S0V SLOW BLOW

5x20mm

140-1002-01

Bussman

GDC 3.15

150-1 209-01

3A

2S0V

4A

250V SLOW BLOW

5x20mm
5x20mm

140-1031-01

SOC
Schurter

FST 034.3123

4A

2S0V SlO-BlO

5x20mm

140-1031-01

Littelfuse

218 004

Technical Volume II

MT4-3.0

MISC-5

PARTS BREAKDOWN

12/90

FUSES - Continued
DESCRIPTION

FUSE

SIZE

SUN PART #

VENDOR

VENDOR
PART #

4A

2S0V 3AG FAST

.2Sxl.2S"

140-1001-01

Littelfuse

318 004

4A

2S0V 3AG FAST

.2Sxl.2S"

Bussman

4A

2S0V 3AB FAST

.2Sxl.2S"

140-1001-01
140-1007-01

AGC4AMP
312004

4A

2S0V 3AB FAST

.2Sxl.2S"

140-1007-01

Bussman

MTH 4

4A

2S0V SLO-BLO

.2Sxl.2S·'

140-1020-01

Littelfuse

313 004

4A

2S0V SLOW BLOW

.2Sxl.2S"

140-1020-01

BEL

4A

2S0V SLOW BLOW

.2Sxl.2S"

140-1 020-01

Power Dynamics

4A

2S0V SLO-BLO

4A

2S0V SLOW BLOW

.2Sxl.2S"
.2Sxl.2S"

150-1033-01
150-1033-01

Littelfuse
Bussman

SA

2S0V SLOW BLOW

SX20mm

140-1029-01

Schurter

SA

2S0V SLO-BLO

SX20mm

140-1029-01

Littelfuse

218005

SA

2S0V SLO-BLO

.2Sxl.2S"

140-1010-01

Littelfuse

313005

SA

2S0V SLOW BLOW

.2Sxl.2S"

140-1010-01

Bussman

MDA (5 AMP)

SA

2S0V SLOW BLOW

Sx20mm

Schurter

SA

2S0V SLOW BLOW

Sx20mm

140-1025-01
140-1025-01

BEL

SMTS

SA

2S0V SLO-BLO

Sx20mm

140-1025-01

Littelfuse

218 DOS

SA

2S0V

Sx20mm

140-1009-01

Littelfuse

212 OS.3

SA

2S0V

Sx20mm

140-1009-01

Bussman

GMA S

SA

2S0V NORMAL-BLO

.2Sxl.2S"

140-1011-01

Littelfuse

314 ODS

SA

2S0V NORMAL-BLO

.2Sx1.2S"

140-1011-01

Bussman

ABC 6A 250V

SA

2S0V FAST

.2Sxl.2S"

140-1021-01

Littelfuse

312 006

6A

2S0V FAST

.2Sxl.2S"

140-1021-01

Bussman

MTH-6A

6A

2S0V FAST

.2Sxl.2S"

140-1021-01

Power Dynamics

19340-6A

6A

2S0V SLOW BLOW

Unknown

140-1026-01

Bussman

2S0(MSL)

6A

2S0V SLOW BLOW

Sx20mm

150-0473

Panel Component

6A

250V SLO-BLO

5x20mm

lS0-0473

Littelfuse

213 006
FST 034.3125

Littelfuse

3SB4
19341-4A
313 004
MDA 4A,2S0V
034.3124

034.3914

341524

S.3A

2S0V SLOW BLOW

SX20mm

140-1030-01

Schurter

6.3A

2S0V SLO-BLO

SX20mm

140-1030-01

Littelfuse

218063

7A

2S0V SLO-BLO

.2Sxl.2S"

lS0-12S8-01

Littelfuse

313007

7A

2S0V SLOW BLOW

.2Sxl.2S"

lS0-12S8-01

Bussman

MDQ-7

8A

2S0V 3AB NORMAL-BLO .2Sxl.2S"

140-1006-01

Littelfuse

314008

8A

2S0V 3AB NORMAL-BLO .2Sxl.2S"

140-1006-01

Bussman

MTH 8

lOA

2S0V SLO-BLO

.2Sxl.25"

140-1017-01

Littelfuse

326 010

lOA

2S0V SLOW BLOW

.2Sxl.2S"

140-1017-01

Power Dynamics

19341-10A

12A

2S0V NORMAL-BLO

.2Sxl.2S"

140-8000-01

Bussman

ABC-12

12A

2S0V NORMAL-BLO

.2Sxl.2S"

140-8000-01

Littelfuse

314.012

lSA

2S0V NORMAL-BLO

.2Sxl.2S"

140-1019-01

Littelfuse

31401S

lSA

2S0V SLOW BLOW

.2Sxl.2S"

140-1019-01

Bussman

ABC-1SA

MISC-6

Field Engineer Handbook

12/90

PARTS BREAKDOWN

FUSES - Continued
DESCRIPTION

SUN PART #

VENDOR

VENDOR
PART #

Fuse Carrier, Domestic

150-1042-01

Schurter

FEK 031 .1666

Fuse Carrier, International

150-1051-01

Schurter

031.1663
552844-1

Fuse Holder, In Line 22-14AWG

140-1023-01

AMP

Fuse Holder, In Line 22-14AWG

140-1023-01

Littelfuse

155020U

Fuse Holder, ULlCSAIVDE

150-1041-01

Schurter

FEU 031.1693
281 007

Fuse Holder, RIA for PIG-TAIL

150-1163-01

Littelfuse

Fuse Holder, RIA for PIG-TAIL

150-1163-01

Power Dynamic

19557

Fuse Holder, 20A,250V,UL,16A,250V

150-1177-01

Schurter

FEU031.1673

Fuse Holder, PNL MT,MICROFUSE STY

150-1179-01

Littelfuse

282 002

Fuse Holder, PNL MT,MICROFUSE STY

150-1179-01

Littelfuse

282 008

Fuse Holder

150-1024-01

Littelfuse

345 001

Fuse Holder, Faston Type

150-1026-01

Littelfuse

571 007

Fuse Holder, Faston Type

150-1026-01

Bussman

HPF

Fuse Holder, Quick Connect

150-1029-01

Bussman

HTA-HH

Fuse Holder, Quick Connect

150-1029-01

Littelfuse

342 858

Technical Volume II

MISC-7

PARTS BREAKDOWN

12/90

Recommended Service Tools
SUN PART#

240-1433-01
345-1184-01
240-1718-01
240-1719-01
250-1007-01
250-1011-01
250-1024-01
250-1025-01
250-1026-01
250-1027-01
250-1028-01
250-1029-01
250-1030-01
250-1031-01
250-1032-01
250-1033-01
250-1034-01
250-1035-01
250-1036-01
250-1037-01
250-1038-01
250-1039-01
250-1040-01
250-1041-01
250-1042-01
250-1043-01
250-1044-01
250-1045-01
250-1046-01
250-1047-01
250-1048-01
250-1049-01
250-1050-01
250-1051-01
250-1052-01
250-1053-01
250-1054-01

MISC-8

DESCRIPTION

2mm Hex Key
SIMM Extraction Tool
EPROM Insertion Tool
IC Extraction Tool
Disposable ESD Wrist Strap
Slotted & 2 mm Hex Screwdriver
T9 Torx Screwdriver
T7 Torx Screwdriver
T25 Torx Blade
#2 Pozidrive Blade
Sun Field Engineers Tool Kit
3/32" Hexdriver Blade
7/64" Hexdriver Blade
14 mm Deep Socket
T20 Torx Blade
Blue Cordora Zipper Case
3 1/8" Driver Handle
4 1/8" Driver Handle
1/4" Drive Spinner Handle
5" Extension Blade
#1 Phillips Blade
#2 Phillips Blade
1/4" Slotted Blade
3/16" Slotted Blade
Alignment Tool
Alignment Tool
4 1/2" Miniature Diagonal Cutter
5.25" Diagonal Cutting Pliers
6.5" Thin Needlenose Pliers
4" Adjustable Wrench
6" Adjustable Wrench
Crimping Tool/Wire Stripper
Fluke 75 Digital Multimeter
1.27 mm Hexdriver Blade
1.5 mm Hexdriver Blade
2 mm Hexdriver Blade
2.5 mm Hexdriver Blade

Field Engineer Handbook

12/90

PARTS BREAKDOWN

Recommended Service Tools
Continued
SUN PART#

250-1055-01
250-1056-01
250-1057-01
250-1058-01
250-1059-01
250-1060-01
250-1061-01
250-1062-01
250-1063-01
250-1064-01
250-1065-01
250-1066-01
250-1067-01
250-1068-01
250-1074-01
250-1075-01
250-1076-01
250-1077-01
250-1078-01
250-1079-01
250-1080-01
250-1081-01
250-1082-01
250-1083-01
250-1084-01
330-1145-01

Technical Volume II

DESCRIPTION

3 mm Hexdriver Blade
4 mm Hexdriver Blade
5 mm Hexdriver Blade
4 mm Nutdriver Blade
4.5 mm Nutdriver Blade
5 mm Nutdriver Blade
5.5 mm Nutdriver Blade
6 mm Nutdriver Blade
7 mm Nutdriver Blade
8 mm Nutdriver Blade
9 mm Nutdriver Blade
10 mm Nutdriver Blade
11 mm Nutdriver Blade
T15 Torx Blade
1O-lnch End Cutter
Cordless Power Screwdriver Kit
Two Speed Power Screwdriver
Screwdriver Carrying Case
Screwdriver Battery Charger
Screwdriver Battery
Vacuum Cleaner Kit
Vacuum Cleaner
Vacuum Cleaner Filters (qty 6)
Vacuum Cleaner Carrying Bag
Power Screwdriver Xcelite Adapter
Disposable ESD Mat

MISC-9

TROUBLESHOOTING

12/90

Troubleshooting
This section contains CPU, Disk, Tape, and Communication
troubleshooting reference information.
The CPU section contains CPU LED codes and Sun 4300
Memory Address Decoding charts.
The Disk section contains Drive and Disk Controller status
codes, error codes, sense codes, completion codes, LED
codes, and ISP-80 self tests.
The Tape section contains Tape drives and Tape Controller
self-tests, error codes, and sense codes.
The Communications section contains Keyboard/Mouse
pinouts, Serial Port pinouts, Audio Port pinouts, Parallel Port
pinouts, Ethernet pinouts, RS-232 pinouts, RS-449 pinouts,
RS-530 pinouts, EIA Electrical Characteristics, SCSI
pinouts, FOOl selftest, and FOOl LED codes.

Field Engineer Handbook - Technical Volume II

TROUBLESHOOTING

CPU

TROUBLESHOOTING

12/90

CPU
Sun-2/S0/130/160 . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-2/120/170 ............................
Sun-3/S0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-3/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun 3004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-3/110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun 3200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun 3400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun386i/1S0/2S0 ...........................
Sun-3E ..................................
Sun-4/20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun-4/7S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun 4100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun 4200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun 4300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Sun 4300 Address Decoding .................
Sun 4400 ............................... "
Sun-4/E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..

Field Engineer Handbook - Technical Volume II

2
4
S
6
7
8
9
10
14
16
17
18
19
21
23
24
28
29

TROUBLESHOOTING

12/90

Sun-2/50/130/160
Self-Test Error Codes
•

= ON

LEOs

0- OFF
0

SYSTEM ACTIVITY
A reset sets LEOs to this state

PROBLEM BOARD
CPU or Monitor
PROM bad

0 0 0 0 0 0 00

After complete power-up
sequence

System seems to be
OK

0 0 0 0 . 0 00

Non-maskable interrupt level
obtainable

System running OK

000000 .0

Entering user watchdog
routine

Software BUG

0 0 0 . 0 0 O.

Testing Context Register

CPU Board

0 0 . 0 0 0 O.

Testing constant data in
Sgment Maps

CPU Board

Testing data lines in Segment
Maps

CPU Board

00.000 .0

Testing address dependency
in Segment Maps

CPU Board

00 • • 00 O.

Testing constant data in
Page Maps

CPU Board

Testing data lines in Page
Maps

CPU Board

00 • • 00 . 0

Testing address dependency
in Page Maps

CPU Board

0 . 0 0 0 0 00

Testing PROM contents

CPU or Monitor
PROM bad

0 . 0 . 0 0 00

Test SCC IC's

CPU Board

0 • • • 00 00

Sizing Memory before constant test
Testing constant data in
Memory

Check CPU then
EXP Memory
Check CPU then
EXP Memory

Testing address dependency
in Memory

Check CPU then
EXP Memory

Testing Parity circuitry

Check CPU then
EXP Memory

. 0 0 0 0 0 O.

Testing Timer IC

CPU Board

0 0 0 0 0 0 O.

Finished Self-Test setting
up to BOOT

CPU then EXP
Memory

After local Memory verified

CPU Board

7

• • • ••• ••

00.000

00 • • 00

••

••

0 • • • 00 O.
0 • • • 00 . 0
0 •••••

000000

CPU-2

••

••

Field Engineer Handbook

TROUBLESHOOTING

12/90

Sun-2/50/130/160
Self-Test Error Codes - Continued
• = ON
7
LEOs

a

= OFF
0

SYSTEM ACTIVITY

PROBLEM BOARD

00000 • • •

After Diagnostics while
setting up

CPU Board

•••• 000.

Setting up memory after
Diagnostics

CPU then EXP
Memory

•••• 00.0

Setting up Maps after
Diagnostics

CPU Board

• • • • 00 • •

Setting up Frame Buffer

CPU then check
video jumpers

•••• 0.00

Setting up NMI or Keyboard

CPU Board

Technical Volume II

CPU-3

TROUBLESHOOTING

12/90

SUN-2/120/170
Self-Test Error Codes
• ; ON
7

0; OFF
LEOs
0

SYSTEM ACTIVITY

PROBLEM BOARD

•••••• • •

Resets set LEOs

CPU Board

0 0 0 0 0 0 O.

Initial state on power-up

CPU Board (MMU)

After local memory verified

CPU Board

After diags. while setting up

CPU Board

0 0 0 0 0 0 00

After reset processing in
monitor

CPU Board

0 0 0 0 . 0 00

Blinks off and on while NMI ok

CPU Board

000000 .0

Entering user watchdog routine

CPU Board

0 0 0 . 0 0 O.

Testing context registers

CPU Board

00.000

o.

Testing constant data in
segMap

CPU Board

00.000

••

Testing data lines in segMap

CPU Board

00.00.

o.

Testing alternating data in
segMap

CPU Board

:restin~ address-dependency

CPU Board

Testing constant data in
pgMap

CPU Board

Testing data lines in pgMap

CPU Board

:resti~

address-dependency
In pg ap

CPU Board

Testing alternating data in
pgMap

Check CPU then
EXP Memory

0 • • • 00 00

Sizing memory before const
test

CPU Board (MMU)

O. • • 00 O •

Testing constant data in
memory

Memory

o.

Testing address-dependency
in memory

Memory

Testing parity circuity

Memory

Testing timer chip

CPU Board

000000
00000 •

••
••

00.000 .0

In seg ap

00 • • 00 O.
00 • • 00

••

00 • • 00 . 0
00 • • 0 .

o.

• • 00 . 0

0 •••••

••

. 0 0 0 0 0 O.

CPU·4

Field Engineer Handbook

12/90

TROUBLESHOOTING

Sun-3/50
Self-Test Error Codes
0= OFF
• = ON
0
LEDs
7

SYSTEM ACTIVITY

PROBLEM BOARD

A reset sets LEDs to this state

CPU or PROMs bad

0 0 0 0 0 0 00

Test 0 checking CPU to SCC
path

CPU Board (SCC)

. 0 0 0 0 0 00

Test 1 checking the boot
PROM

Boot PROM

• • 0 0 0 0 00

Test 3 checking the Context
Register

CPU Board (MMU)

0 0 . 0 0 0 00

Test 4 Segment Map RAM
Rd/Wr Test

CPU Board (MMU)

. 0 . 0 0 0 00

Test 5 checking Segment
Map RAM

CPU Board (MMU)

0 • • 0 0 0 00

Test 6 checking Page Map
RAM

CPU Board (MMU)

• • • 0 0 0 00

Test 7 checks memory data
path

CPU Board

0 0 0 . 0 0 00

Test 8 checks bus error
detection

CPU Board

. 0 0 . 0 0 00

Test 9 checks interrupt
capabilities

CPU Board

0 . 0 . 0 0 00

Test 10 checking MMU
read access

CPU Board

• • 0 . 0 0 00

Test 11 checking MMU
write access

CPU Board

00 • • 00 00

Test 12 writing to invalid
page

CPU Board

. 0 • • 00 00

Test 13 tries to write to
protected page
Test 14 performs parity
error check

CPU Board

• • • • 00 00

Test 15 performs parity
error check

CPU Board

0 0 0 0 . 0 00

Test 16 performs memory
tests

CPU Board

o.

Self-tests have found an
error

CPU Board

000000 .0

An Exception Class error
was found

CPU Board

0 0 0 0 0 . 00

Self-test done,UNIX in bootstate (LED is blinking)

CPU Board

•••••• ••

0 • • • 00 00

000000

Technical Volume II

CPU Board

CPU-5

TROUBLESHOOTING

12/90

Sun-3/60
Self-Test Error Codes
• : ON
0 : OFF
7
LEOS
a
0000000.

SYSTEM ACTIVITY

PROBLEM BOARD

PROM checksum test

CPU

Context register test

CPU Board

0 0 0 0 0 . 00

Segment Map rd/wr test

Boot PROM

0 0 0 0 0 . O.

Segment Map address test

CPU Board

00000. .0

Page Map test

CPU Board

Memory path data test

CPU Board

NXM buss error test

CPU Board

Interrupt test

CPU Board

TOO clock interrupt test

CPU Board

000000

00000 •

••

••

0 0 0 0 . 0 00
0000.0

o.

0000.0 .0
0000.0

••

MMU protection/status test

CPU Board

0000 ••

eo

Parity error test (#1)

CPU Board

0000 ••

••

Parity error test (#2)

CPU Board

0 0 0 . 0 0 00

Memory test

CPU Board

. 0 0 0 0 0 00

Error found

CPU Board

0 . 0 0 0 0 00

Exception class error found

CPU Board

0 0 . 0 0 0 00

Self-test done (LED flashing)

CPU Board

• • •••• ••

Reset

CPU Board

CPU-6

Field Engineer Handbook

12/90

TROUBLESHOOTING

Sun 3004
Self-Test Error Codes
•

a

= ON

a
LEOs

= OFF

SYSTEM ACTIVITY

7

• ••••• ••

A reset sets LEOs to this state

PROBLEM BOARD
CPU or PROMs bad
or +5VDC is low
Boot PROM

. 0 0 0 0 0 00

Test Ox01 checking the boot
PROM

0 . 0 0 0 0 00

Test Ox02 checking DVMA
Register

CPU Board

• • 0 0 0 0 00

Test Ox03 checking the
Context Register

CPU Board (MMU)

0 0 . 0 0 0 00

Test Ox04 Segment Map RAM
Rd/Wr Test

CPU Board (MMU)

. 0 . 0 0 0 00

Test Ox05 checking Segment
Map RAM

CPU Board (MMU)

0 • • 0 0 0 00

Test Ox06 checking Page Map
RAM

CPU Board (MMU)

• • • 0 0 0 00

Test Ox07 checks memory data
path

CPU Board

0 0 0 . 0 0 00

Test Ox08 checks bus error
detection

CPU Board

. 0 0 . 0 0 00

Test Ox09 checks interrupt
capabilities

CPU Board

0 . 0 . 0 0 00

Test OxOA performs TOO clock
interrupt test

CPU Board

• • O. 00 00

Test OxOB checking MMU protection and status

CPU Board (MMU)

00 • • 00 00

Test OxOC performs parity
error check

CPU Board

. 0 • • 00 00

Test OxOD performs parity
error check

CPU Board

Test OxOE performs memory
tests
Self-tests have found an
error

CPU Board

000000 .0

An Exception Class error
was found

CPU Board

0 0 0 0 0 . 00

Self-test done,UNIX in bootstate (LED is blinking)

CPU Board

O •••

a a

00

0 0 0 0 0 0 O.

Technical Volume 1/

CPU Board

CPU-?

TROUBLESHOOTING

12/90

Sun-3/110
Self-Test Error Codes
• =ON
0

a =OFF

LEOs

7

•••••• ••

SYSTEM ACTIVITY

PROBLEM BOARD

A reset sets LEDs to this state

CPU or PROMs bad
or +5VDC is low
Boot PROM

. 0 0 0 0 0 00

Test OxOl checking the boot
PROM

0 . 0 0 0 0 00

Test Ox02 checking DVMA
Register

CPU Board

• • 0 0 0 0 00

Test OX03 checking the
Context Register

CPU Board (MMU)

0 0 . 0 0 0 00

Test Ox04 Segment Map RAM
Rd/Wr Test

CPU Board (MMU)

. 0 . 0 0 0 00

Test Ox05 checking Segment
Map RAM

CPU Board (MMU)

0 • • 0 0 0 00

Test Ox06 checking Page Map
RAM

CPU Board (MMU)

• • • 0 0 0 00

Test Ox07 checks memory data
path

CPU Board

0 0 0 . 0 0 00

Test Ox08 checks bus error
detection

CPU Board

. 0 0 . 0 0 00

Test Ox09 checks interrupt
capabilities

CPU Board

0 . 0 . 0 0 00

Test OxOA performs TOO clock
interrupt test

CPU Board

• • 0 . 0 0 00

Test OxOB checking MMU
protection and status

CPU Board (MMU)

00 • • 00 00

Test OxOC performs parity
error check

CPU Board

. 0 • • 00 00

Test OxOD performs parity
error checks
Test OxOE performs memory
tests

CPU Board

a ••• a a

00

000000

o.

Self-tests have found an
error

CPU Board

000000 .0

An Exception Class error
was found

CPU Board

0 0 0 0 0 . 00

Self-test done, UNIX in bootstate (LED is blinking)

CPU Board

CPU-8

CPU Board

Field Engineer Handbook

12/90

TROUBLESHOOTING

Sun 3200
Self-Test Error Codes
• =ON

LEDs

a =OFF

SYSTEM ACTIVITY
A reset sets LEDs to this state

PROBLEM BOARD
CPU or PROMs bad
or +5VDC is low

. 0 0 0 0 0 00

Test Ox01 checking PROM
checksum

Boot PROM

0 . 0 0 0 0 00

Test Ox02 checking DVMA
Register

CPU Board

• • 0 0 0 0 00

Test OX03 checking the
Context Register

CPU Board (MMU)

0 0 . 0 0 0 00

Test Ox04 Segment Map RAM
wr/rd test

CPU Board (MMU)

. 0 . 0 0 0 00

Test Ox05 checking Segment
Map RAM

CPU Board (MMU)

0 • • 0 0 0 00

Test Ox06 checking Page Map
RAM

CPU Board (MMU)

• • • 0 0 0 00

Test Ox07 performs memory
path data test

CPU or Memory
Board

0 0 0 . 0 0 00

Test Ox08 is nonexistent memory bus error test

CPU or Memory
Board

.ooeoo

Test Ox09 checks interrupt
capabilities

CPU Board

0 . 0 . 0 0 00

Test OxOA performs TOD clock
interrupt test

CPU Board

• • 0 . 0 0 00

Test OxOB checking MMU protection and status

CPU Board (MMU)

00 • • 00 00

Test OxOC performs ECC error
test

CPU or Memory
Board

Test OxOD performs cache
data 3 pattern test
Test OxOE performs cache tag
3 pattern test

CPU Board

0

7

•••••• ••

.0 ••

a

00

0 00

0 • • • 00 00
• • • • 00 00

CPU Board

Test OxOF performs memory
tests

CPU or Memory
Board

Initializing MMU

CPU Board

0.00 ••

••

000000

o.

Self-tests have found an
error

CPU or Memory
Board

000000 .0

An Exception Class error
was found

CPU or Memory
Board

0 0 0 0 0 . 00

Self-test done, UNIX in bootstate (LED is blinking)

CPU or Memory
Board

Technical Volume /I

CPU-9

TROUBLESHOOTING

12/90

Sun 3400
Self-Test Error Codes
• ~ ON
o ~ OFF
LEOs
0
7
. 0 00 0 0 0 0

SYSTEM ACTIVITY
Test Ox01 transmit character
test OK (not error condition)

PROBLEM BOARD
CPU to Terminal
Port A OK

0 0 00 00 O.

Value Ox80 error in SCC Port
A. B write/write/read test

CPU to Terminal Port
A and B (SCC)

O . 00 00 O.

Value Ox82 error in system
enable register read test

CPU Board

00 O. 00 O.

Value Ox88 error in memeory
read/write tests

CPU Board (MMU)

• 0 O . 00 O •

Value Ox89 error in memory
address tests

CPU Board (MMU)

o •

Value Ox8A error in memory
3-pattern tests

CPU Board (MMU)

Value Ox8B error in marching
Os. 1s on memory

CPU Board

Value Ox8C error in read byte
alignment tests

CPU Board

Value Ox8D error in write byte
alignment tests

CPU Board

Value Ox8E error in parity
memory no error tests

P2 MEZZ Mem Board

Value Ox8F error in parity
memory forced error tests

P2 MEZZ Mem Board

00 00 • 0 O •

Value Ox90 error in writelwritel
read 1/0 mapper

CPU Board

. 0 00 • 0 O •

Value Ox91 error in I/O mapper
RAM tests

CPU Board

O . 00 . 0 O.

Value Ox92 error in 3-pattern
I/O mapper RAM test

CPU Board

••

Value Ox93 error in bus error
register test

CPU Board

Value Ox94 error in level 1
interrupt test

CPU Board

0 .0 .0 O •

Value Ox95 error in level 2
interrupt test

CPU Board

O. .0 • 0 O •

Value Ox96 error in level 3
interrupt test

CPU Board

Value Ox97 error in TOO clock
interrupt test

CPU Board

O. 000.

• • O.
00
•

000.

• • 00 O •

0 •

• 00 O •

O . • • 00 O •

•••

• 00 O •

00 • 0 O •

00 . 0 . 0 O.
•

• • .0

. 0 O.

00 O . . 0 O.
•

0 O •

CPU-10

.00.

Value Ox98 error in central
CPU Board
cache tag write/write Ire ad tests
Value Ox99 error in central
cache tag RAM address test

CPU Board

Field Engineer Handbook

TROUBLESHOOTING

12/90

Sun 3400
Self-Test Error Codes
• = ON
0= OFF
0
LEDs
7
0

•

SYSTEM ACTIVITY

PROBLEM BOARD

o •

Value Ox94 error in central
cache tag Ram 3-pattern test

CPU Board

o

0

Value Ox9B error in central cache
data RAM write/write/read test

CPU Board

••• 0

o •

Value Ox9C error in central cache
data RAM address test

CPU Board

••• 0

o •

Value Ox9D error in central cache
data RAM 3-pattern test

CPU Board

0 •• 0

••0

•• 0

o

0

•

0

0

• •••

00.

Value Ox9E error in central cache
data RAM read byte alignment

CPU Board

• ••••

00.

Value Ox9F error in central cache
data RAM write byte alignment

CPU Board

o.

Value OxA5 error in lac tag RAM
write/write/read tests

CPU Board

o •

Value OxA6 error in lac tag RAM
address test

CPU Board

Value OxA7 error in lac tag RAM
3-pattern test

CPU Board

o •

Value OxA8 error in lac data RAM
write/write/read test

CPU Board

0 . 0 . O.

Value OxA9 error in lac data RAM
address test

CPU Board

.00.
•

0

o ••

00.

• • .00. o •
o

0 0.0.

•

0

0

•

0.0. O •

Value OxAA error in lac data RAM
3-pattern test

CPU Board

•

•

0.0. O •

CPU Board

0

0 • • 0. O.

Value OxAB error in lac data RAM
read byte alignment test
Value OxAC error in lac data RAM
write byte alignment test

•

0 • • 0. O.

Value OxAD error in ECC 'no error'
test

CPU Board

0

•

• • 0. O.

Value OxAE error in ECC forced CE
test

CPU Board

•

•••• 0.0

Value OxAF error in ECC forced UE
test

CPU Board

0

0 00 • •

o.

Value OxBO error in central cache
read hit test

CPU Board

•

0 00 • • O.

Value OxB1 error in central cache
invalid read miss test

CPU Board

0

•

Value OxB2 error in central cache
valid read miss test

CPU Board

00 • •

o.

Technical Volume.1I

CPU Board

CPU-11

TROUBLESHOOTING

12/90

Sun 3400
Self-Test Error Codes
.
0 " ON LEOs

•

0= OFF
7

•• o •
•• O .

SYSTEM ACTIVITY

PROBLEM BOARD

Value OxB3 error in central cache
write miss test

CPU Board

Value OxB4 error in central cache
write miss. no writeback test

CPU Board

Value OxBS error in central cache
write miss. writeback test

CPU Board

Value OxB6 error in central cache
cross-invalid read miss test

CPU Board

Value OxB? error in central cache
line cross write miss write back test

CPU Board

Value OxBS error in central cache
writeback timeout test

CPU Board

O •

Value OxB9 error in block copy text
(source:cache hit.dest;cache miss)

CPU Board

o •

Value OxBA error in block copy test
(source:cache hit.dest:cache hit)

CPU Board

0 ••

o •

Value OxBB error in block copy test
(source:cache hit.dest:cache miss)

CPU Board

00.

•••

o •

Value OxBC error in block copy test
(source:cache hit.dest:cache hit)

CPU Board

.0.

••• o.

Value OxBD error in memory writel
write/read test (central cache on)

CPU Board

• ••

•• 0

•

••• • •

.0 0

00. 0

• • ••
0

0

o • •

O •

0 •• 0

•

• • • ••
•••o •
0

O.

0 0 0

.00 •

o •

0 •

•

0

•

•

0

••
••

000 000
.00 000

. 0 0 0 00

••

0 0 00

o

0 •

•

0.000

o •

•

CPU-12

0 00

000

••

h

Value OxBE error in memor write/
write/read test (central cac e and
68030 on)

CPU Board

Value OxBF error in VME/DVMA
loop back test

CPU Board

••
••
••
••
••
••

Value OxCO error in lac read hit test

CPU Board

Value OxC1 error in lac invalid read
miss test

CPU Board

Value OxC2 error in lac write hit test

CPU Board

Value OxC3 error in lac write miss.
no writeback test

CPU Board

Value OxC4 error iniaC write miss.
writeback test

CPU Bo?rd

Value OxCS error in lac read miss .•
writeback test

CPU Board

••

Value OxC6 error in lac valid write
hit (central cache match. unmod)
test

CPU Board

Field Engineer Handbook

TROUBLESHOOTING

12/90

Sun 3400
Self-Test Error Codes
•0 =ON

LEDs

a =OFF

SYSTEM ACTIVITY

7

PROBLEM BOARD

• • • a a a ••

Value OxC7 error in lac invalid
write miss (central cache match.
unmod) test

CPU Board

000.00 ••

Value OxC8 error in lac invalid read
miss (central cache match. unmod)
test

CPU Board

.00.00 ••

Value OxC9 error in lac invalid read
miss (central cache match. mod)
test

CPU Board

0.0.00 ••

Value OxCA error in lac valid read
miss (central cache match) writeback test

CPU Board

Value OxCB error in lac (valid. mod
flush test

CPU Board

Value OxCC error in lac (valid. not
modified) flush test

CPU Board

Value OxCD error in lac (not valid.
not modified) flush test

CPU Board

Value OxCE error in 10 mapper
invalid page test

CPU Board

0 ••

Value OxCF error in lac write miss.
write back test

CPU Board

0 0

0

Value OxDO error in lac invalid read
miss test

CPU Board

a

0 •

0 ••

Value OxD1 error in lac write miss
test

CPU Board

o • o

0 •

0 ••

Value OxD2 error in lac random
data block write test

CPU Board

Value OxD3 error in lac random
data block read (central cache off)
test

CPU Board

Value OxD4 error in lac random
data block read (central cache on)
test

CPU Board

••a
o
••
•

0

•

0

•

•

0
0
00

00

••
••
••
••

•••
••••o
a
• ••
a

0 0

0

• a

••

0 0

•a ••

00.0.0 ••

a

0

•

0

•
••

0

0 0

••
••
••
•• •
••

0

a o.

Value OxEO error in P4 video RAM
write/write/read test

P4 Video Board

o

0 O.

Value OxE1 error in P4 video RAM
address test

P4 Video Board

0 0 O.

Value OxE2 error in P4 video
3-pattern test

P4 Video Board

0 0 0

Value OxE3 error in P4 video RAM
read byte alignment test

P4 Video Board

Value OxE4 error in P4 video RAM
byte alignment test

P4 Video Board

•

0 O.

Technical Volume II

CPU-13

TROUBLESHOOTING

12/90

Sun386i/150/250
SUBSYSTEM TEST
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
2

2
2
2
2
2
2
2
3
3
3
3
3
3

Self-Test Error Codes
.= ON a =OFF
7

LEOs

0

1
2
3

000.0000

4

0.000000

5

0.0.0000

6

0 •• 00000

00.00000
00 • • 0 0 0 0

7

0 • • • 0000

0
1

0000000.
000.000.

2

00.0000.

3

00 • • 0 0 0 .

4

0.00000.

5
6
7

0.0.000.

0
1
2
3

000000.0

0 •• 0000.
0 ••• 000.

000.00.0
00.000.0
00 • • 0 0 . 0

4

0.0000.0

5
6
7

0.0.00.0

0
1

000000 ••
000.00 ••

2

00.000 ••

3

00 • • 00 • •

0 •• 000.0
0 ••• 00.0

4

0.0000 ••

5

0.0.00 ••

4

0

00000.00

4
4
4
4
4
4

1
2
3

000.0.00

CPU-14

4

5
6

ERROR

FRU COMPONENT

Fatal
Warning
Fatal
Warning
Warning
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Warning
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Warning
Non-error
Fatal

CPU Board (80386)
(LED register)
"
"
(Boot PROM)
(Serial Port)
"
(Parallel Port)
"
"
(NVRAM)
(10 PROM)
"
CPU Board (82380)
,
(82380)
,
(82380)
(82380)
"
(82380)
"
"
(82380)
"
(82380)
"
(Ethernet Controller)
CPU Board (82380)
"
(82380)
(82380)
"
"
(82380)
(82380)
"
(82380)
"
(82380)
"
"
(SCSI Bus Controller)
CPU Board (82380)
(82380)
"
" (Floppy Disk Controller)
"
(System Bus)
(System Bus)
"
(MUSCI ASIC)
"
Memory Bd.(System Bus
Slot 1)

Warning
Fatal
Fatal
Fatal
Fatal

Fatal
Fatal
00 • • 0 . 0 0
Fatal
0 . 0 0 0 . 0 0 Fatal & Warning
0 . 0 . 0 . 0 0 Fatal & Warning
0 • • 0 0 . 0 0 Fatal & Warning
00.00.00

"
"

,

"
"

"

(Cache)
(Cache)
(Cache)

Field Engineer Handbook

TROUBLESHOOTING

12/90

Sun386i/150/250
8elf-Test Error Codes - Continued
SUBSYSTEM TEST

.= ON

7

0= OFF

LEDs

0

ERROR

5

0

00000.0.

Fatal

5
5
5

1
2

000.0.0.
00.00.0.

Fatal
Fatal

3

00 • • 0 . 0 .

Fatal

5
5
5
6

4

0.000.0.
0.0.0.0.

0

00000 •• 0

Fatal

1

000.0 •• 0

Fatal
Fatal

..
.

6
6
6
6
6
6

2

00.00 •• 0

3
4

00 • • 0 • • 0

5
6

0.0.0 •• 0

7

0

00000 •••

Fatal

7
7
7
7
7

1

000.0 •••

2

00.00 •••

3
4

Fatal
Fatal
Fatal

0.000 •••

7

0.000 •• 0

0 • • 00 • • 0

00 • • 0 • • •

Fatal
Fatal & Warning
Fatal & Warning
Fatal & Warning

Fatal & Warning
Fatal & Warning
Fatal & Warning

5
6

0.0.0 •••

0
1

0000.000
000 • • 000

Warning
Warning

0 • • 00 • • •

8
8
8
8
8

2

00.0.000

Warning

3
4

00 • • • 000

9
10
11

0
0
0

0000.00.

Warning
Warning
Warning
Warning
Warning

11
12

1
0

000 • • 0 • •
0 0 0 0 • • 00

Warning
Warning

12

1

000 • • • 00

Warning

13

0

0000 •• 0.

Warning

0.00.000

0000.0.0
0000.0 ••

Technical Volume II

"

Memory Bd. (System Bus
Slot 2)
Fatal & Warning "
(Cache)
Fatal & Warning
(Cache)
Fatal & Warning
(Cache)

5
6

0 •• 00.0.

FRU COMPONENT
Memory Bd. (System Bus
Slot 2)
"

Memory Bd. (System Bus
Slot 3)

.
.
..
"

(Cache)
(Cache)
(Cache)
Memory Bd. (System Bus
Slot 4)

..
..

.
..
..
..
.
.

(Cache)
(Cache)

(Cache)
Video Bd. (VRAM)

.
.
..
.

(VRAM)
(Color LUT)

(All)
(Mouse/Kbd SCC)
Mouse/Keyboard (Kbd)
Floppy Disk
SCSI Hard Disk
(Bootable Device)
(Controller)
SCSI Tape Drive
(Bootable Device)

..

.

Ethernet

(Controller)
(Bootable
Device)

CPU-15

TROUBLESHOOTING

12/90

Sun-3/E
Self-Test Error Codes
o = OFF
• = ON
0
LEOs
7

• • • • •• • •

SYSTEM ACTIVITY

A reset sets LEOs to this state

PROBLEM BO.

CPU or PROM

. 0 0 0 0 0 00 Test 1 checking the boot PROM

Boot PROM

o.

CPU

0 0 0 0 00 Test 2 checking DVM A Register

• • 0000 a

a

Test 3 checking the Context Register

00 . 0 0 0 00 Test 4 Segment Map RAM Rd/Wr Test

CPU (MMU)
CPU (MMU)

.0 .000

a a

Test 5 checking Segment Map RAM

CPU (MMU)

o.

a a

Test 6 checking Page Map RAM

CPU (MMU)

Test 7 checks memory data path

CPU

.000

•• •

a a a a a

00 0 . 0 0 0 0 Test 8 c.hecks bus error detection
.0 0.00

a a

Test 9 checks interrupt capabilities

o.

0 . 0 0 00 Test 10 checking MMU read access

••

0.00

a a

Test 11 checking MMU write access

00 • • 00 00 Test 12 writing to invalid page

CPU
CPU
CPU
CPU
CPU

. 0 • • 00

a a

Test 13 tries to write to protected page

CPU

O. • • 00

a a

Test 14 performs parity error check

CPU

• • • • 00 a a

Test 15 performs parity error check

CPU

00 0 0 . 0 00 Test 16 performs memory tests

CPU

00 0 0 0 0 O . Self-Tests have found an error

CPU

00 0 0 0 0 . 0 An Exception Class error was found

CPU

00 0 0 0 . 0 0 Self-rest done, UNIX in boot-state

CPU

(LED is blinking)
.0000000

CPU-16

"Walking Ones" pattern

UNIX running
OK

Field Engineer Handbook

12/90

TROUBLESHOOTING

Sun-4/20
Self Test Error Codes
KEY
•

o

=ON
= OFF

•

= BLINKING
LEOs

5

0

0

0

0

0

0 0

••• •••
•
• ••
• ••
••
• •••
0

Monitor
CPU

0

0

0

0

0

Memory Module, U0502

0

0

0

Memory Module, U0501

0

0

0

0

Technical Volume II

0

DEFECTIVE PART

II

0

II

CPU

Memory Module, U0602
Memory Module, U0601

CPU-17

12/90

TROUBLESHOOTING

Sun-4175
Type 4 Keyboard LEOs
CAPS LOCK

COMPOSE

SCROLL LOCK

NUM LOCK

1-1-1-1-1
KEY
= ON Indicates a 1
CI = OFF Indicates a 0
_

FRU

LED State

--- ----- ------------CI

CI

CI

CI

CI

CI

CI
CI

CI
CI

CI

CI

CI

CI

CI

CI

CI

CI
CI

CI

CI

CI

CI

CI

CI

CI
CI

CI

CI

CI

CI

CI

CPU-18

0000

N/A

0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111

Boot PROM
TOD/NVRAM
CPU board
SIMM U0311
SIMM U0309
SIMM U0307
SIMM U0322

Bank
Bank
Bank
Bank

0
0
0
0

N/A
N/A
N/A
N/A
N/A
N/A
N/A
POSR Passed

Field Engineer Handbook

12/90

TROUBLESHOOTING

Sun 4100
Self-Test Error Codes
•

= ON

LEOs

a

= OFF

SYSTEM ACTIVITY

PROBLEM BOARD

A reset sets LEOs to this state

CPU or PROMs bad
or +5V low

. 0 0 0 0 0 00

Test Ox01 checks PROM
checksum

CPU Board (Boot
PROM)

0 . 0 0 0 0 00

Test Ox02 checks the context
register

CPU Board

• • 0 0 0 0 00

Test Ox03 performs segment
Map tests

CPU Board

0 0 . 0 0 0 00

Test Ox04 checks page Map
RAM

CPU Board

. 0 . 0 0 0 00

Test Ox05 performs software
traps tests

CPU Board (MMU)

0 • • 0 0 0 00

Test OxOS performs interrupt
register test

CPU Board (MMU)

• • • 0 0 0 00

Test Ox07 performs software
interrupts tests

CPU Board (IU)

0 0 0 . 0 0 00

Test Ox08 performs TOO clock
interrupt test

CPU Board

. 0 0 . 0 0 00

Test Ox09 checks video
memory

CPU Board

0 . 0 . 0 0 00

Test OxOA performs P4 color
Map test

P4 Board

• • 0 . 0 0 00

Test OxOB runs limited main
Memory tests

CPU Board

00 • • 00 00

Test OxOC performs MMU
read/write tests

CPU Board

. 0 • • 00 00

Test OxOD=MMU write to protected page test

CPU Board (MMU)

0 • • • 00 00

Test OxOE performs MMU read
invalid page test

CPU Board (MMU)

• • • • 00 00

Test OxOF performs MMU write
invalid page tests

CPU Board (MMU)

0 0 0 0 . 0 00

Test Ox10 performs main Mem
ory, space control timeout test

CPU Board (MMU)

. 0 0 0 . 0 00

Test Ox11 performs range and
size error tests

CPU Board

0 . 0 0 . 0 00

Test Ox12 performs parity
circut test

CPU Board

• • 0 0 . 0 00

Test Ox13 tests cache tag
memory

CPU Board

0

7

•• • ••• ••

Technical Volume II

CPU-19

TROUBLESHOOTING

12/90

Sun 4100
Self-Test Error Codes - Continued
0

LEOs

7

SYSTEM ACTIVITY

PROBLEM BOARD

oo.oeooo

Test Ox14 performs SCSI/DMA
tests

CPU Board

eoeoeooo

Test Ox15 runs main Memory
tests

CPU Board

oooooooe

Self"':tests have found an
Error

CPU Board

ooooooeo

An exception class error is
found

CPU Board

00000.00

Self-tests done, UNIX in boot
state (LED is blinking)

CPU Board

CPU-20

Reid Engineer Handbook

TROUBLESHOOTING

12/90

Sun 4200
Self-Test Error Codes
SYSTEM ACTIVITY
A reset sets LEDs to this state

PROBLEM BOARD
CPU or PROMs bad
or +5VDC is low

. 0 0 0 0 0 00

Test OxOl checks PROM
checksum

CPU Board (Boot
PROM)

0 . 0 0 0 0 00

Test Ox02 checks UDVMA
enable register

CPU Board

• • 0 0 0 0 00

Test Ox03 checks UDVMA
Map

CPU Board

0 0 . 0 0 0 00

Test Ox04 checks the
context Register

CPU Board (MMU)

. 0 . 0 0 0 00

Test Ox05 performs Segment
Map RAM

CPU Board (MMU)

o.

Test Ox06 checks page Map
RAM

CPU Board (MMU)

•• . 0 0 0 00

Test Ox07 performs Software
traps test

CPU Board

0 0 0 . 0 0 00

Test Ox08 performs interrupt
Register test

CPU Board

. 0 0 . 0 0 00

Test Ox09 performs Software
Interrupts test

CPU Board

0 . 0 . 0 0 00

Test OxOA performs TOD clock
interrupt test

CPU Board

• • 0 . 0 0 00

Test OxOB checks Video
Memory

CPU Board

00 • • 00 00

Test OxOC performs limited
main Memory tests

CPU or Memory
Board

. 0 • • 00 00

Test OxOD performs MMU
read/write tests

CPU Board (MMU)

0 • • • 00 00

Test OxOE performs MMU write
to protected page test

CPU Board (MMU)

• • • • 00 00

Test OxOF performs MMU read
invalid page tests

CPU Board (MMU)

0 0 0 0 . 0 00

Test Oxl0 performs MMU
write invalid page test

CPU Board (MMU)

. 0 0 0 . 0 00

Test Oxll performs main
Memory timeout test

CPU Board

0 . 0 0 . 0 00

Test Ox12 performs control
space timeout test

CPU Board

• • 0 0 . 0 00

Test Ox13 performs range
error test

CPU Board

0

LEDs

7

•••••• ••

. 0 0 0 00

Technical Volume II

CPU-21

TROUBLESHOOTING

12/90

Sun 4200
8elf-Test Error Codes - Continued
0

LEOs

7

PROBLEM BOARD

SYSTEM ACTIVITY

0 0 . 0 . 0 00

Test Ox14 performs size
error test

CPU Board

. 0 . 0 . 0 00

Test Ox15 test ECC circuits

Memory Board

0 • • 0 . 0 00

Test Ox16 tests cache tag
Memory

CPU Board

• • • 0 . 0 00

Test Ox17 tests cache data
Memory

CPU Board

0 0 0 • • 0 00

Test Ox18 is cache write/read
hit/miss verify test

CPU Board

.00 •• 000

Test Ox19 is cache write/read/
flush verify test

CPU Board

0 . 0 • • 0 00

Test Oxl A runs main Memory
tests

Memory Board

Self-tests have found an error

CPU or Memory
Board

000000.0

An exception class error is
found

CPU or Memory
Board

00000.00

Self-tests done. UNIX in boot
state (LED is blinking)

CPU or Memory
Board

000000

CPU-22

o.

Field Engineer Handbook

12/90

TROUBLESHOOTING

Sun 4300
8elf-Test Error Codes
LEDs

7

00 0 0 0 0 00
00 0 0 00

SYSTEM ACTIVITY

0

o.

LED Loop Test
Initialize SCC UART
"BOOT PROM Self test " Message

00 0 0 00 . 0
00 0 0 00

••

00 00 O. 00

EPROM Checksum Test
Context Register Read-Write Test

0 0 0 0 O. O.

Segment Map Tests

00 00 O. . 0

Page Map Tests

0 0 0 0 O.

••

Software Traps Test

00 00 . 0 00

Interrupt Tests (Software and Register)

00 0 0 • 0 O •

TaD Interrupt Test

00 0 0 . 0 . 0

Video Memory Tests

••

Main Memory Tests

00

MMU Read Access/Modified Bits Test

• • .O.
•• 0

MMU Write Access/Modified Bits Test

00 00 • 0
00 00
00 00
00 00
000 0
000
000
000
00

•
•
•

000
000
000
000
000

MMU Read Not-Writeable Invalid Page Test

00 00

MMU Read Writeable Invalid Page Test

00 O.

MMU Write Not-Writeable Invalid Page Test

00 . 0

MMU Write Writeable Invalid Page Test

00

00

• O. O.
• O.
• O. • •
•
•
.0

0 00.

Range Error Test
Size Error Test
Parity Memory Test

. 0 00

CPU Cache Tag RAM Tests
CPU Cache Data RAM Tests

• .0 .0
000
•• 0 ••
0 00.

Main Memory Timeout Test
Control Space Timeout Test

.00.

000

000.

MMU Write to Write=Protected Page Test

•• ••

.0. • •

o •

000

••

CPU Cache Functional Tests
VME Loopback Tests

••

00

• • O.

lac Data RAM Tests

••

.0

lac Functional Tests

lac Tag RAM Tests

Technical Volume II

CPU-23

12/90

TROUBLESHOOTING

Sun 4300 Address Decoding
The physical address and the byte in error are used to determine
a failing SIMM module. Socket locations are silkscreened on the
component side of the CPU and 3U Memory Boards. and on the
solder side of the 9U Memory Board. This section includes examples
of errors and charts for the Sun 4300 CPU, 3U Memory Boards and
9U Memory Boards.

Error Examples
CPU Switch In NORM Position
Parity Error detected on byte 0
(Physical address Ox01000000) with PC OxFFE90048
Parity Error detected on byte 2

The location of the failing SIMM module is U1702.
CPU Switch In DIAG Position
error: at OxOOOFFF8. expect Ox5A972C5a. obs Ox5AFE2C5 (looping)
Physical Address: Ox010FFFF8
(3U expansion memory) Expansion board #1 SIMM in Error: U0802
(9U expansion memory) SIMM in Error: U1702

The location of the failing SIMM module is U1702.
Unexpected parity_memory_error at PC Oxffea1d4c.
Memory Error Address Register: OxOOOffffc. Instruction: d2030000.
Memory Error Control Register: Ox00000054.
Physical address: Ox004ffffc.
CPU board SIMM in Error: U1306
error: at addr OxOOOffffc. expect OxOOOffffc. obsOx00000002. (looping)
Physical address: Ox004ffffc.

The location of the failing SIMM module is U1306.
Sun-4300 CPU Board Memory Addressing
BANK

BYTE

SOCKET

0-4MB
0-4MB
0-4MB
0-4MB

000000-3fffff
000000-311fff
000000-3fffff
00OOOO-3fffff

0
0
0
0

0
1
2
3

U1300
U1301
U1302
U1303

4-8MB
4-8MB
4-8MB
4-8MB

400oo0-7ffffl
400000-711111
400000-7fffff
400000-7fffff

1
1
1
1

0
0
1
1

U1304
U1305
U1306
U1307

ADDRESS (Dec)

CPU-24

ADDRESS (Hex)

Field Engineer Handbook

TROUBLESHOOTING

12/90

Sun 4300 Address Decoding
Continued
1st Sun-4300 3U Memory Board Addressing
BANK

BYTE

SOCKET

a-12MB
a-12MB
B-12MB
B-12MB

BOOOOO-bfffff
BOOOOO-bfffff
BOOOOO-bfffff
BOOOOO-bfffff

0
0
0
0

0
1
2
3

U700
U701
U702
U703

12-1SMB
12-1SMB
12-16MB
12-16MB

cOOOOO-ffffff
cOOOOO-ffffff
cOOOOO-ffffff
cOOOOO-ffffff

1
1
1
1

0
1
2
3

U704
U705
U706
U707

16-20MB
lS-20MB
lS-20MB
lS-20MB

1000000-13fffff
1000000-13 fffff
1000000-13fffff
1000000-13fffff

2
2
2
2

0
1
2
3

UBOO
UBOl
UB02
UB03

20-24MB
20-24MB
20-24MB
20-24MB

1400000-1 7fffff
1400000-1 7fffff
1400000-17fffff
1400000-17fffff

3
3
3
3

0
1
2
3

UB04
UB05
USOS
UB07

ADDRESS (Dec)

ADDRESS (Hex)

2nd Sun-4300 3U Memory Board Addressing
ADDRESS (Dec)

ADDRESS (Hex)

BANK

BYTE

SOCKET

24-2SMB
24-2SMB
24-2SMB
24-2SMB

lS00000-1 bfffff
lS00000-1 bfffff
lS00000-1 bfffff
lS00000-1 bfffff

0
0
0
0

0
1
2
3

U700
U701
U702
U703

2B-:32MB
2S-32MB
2S-32MB
2B-32MEl

1cOOOOO-l ffffff
1cOOOOO-l ffffff
1cOOOOO-l ffffff
1cOOOOO-lffffff

1
1
1
1

0
1
2
3

U704
U705
U70S
U707

32-3SMB
32-3SMB
32-3SMB
32-3SMB

2000000-23fffff
2000000-23fffff
2000000-23fffff
2000000-23fffff

2
2
2
2

0
1
2
3

USOO
USOl
US02
US03

3S-40MB
3S-40MB
3S-40MB
3S-40MB

2400000-27fffff
2400000-27fffff
2400000-27fffff
2400000-27fffff

3
3
3
3

0
1
2
3

US04
US05
USOS
US07

Technical Volume II

CPU·25

12/90

TROUBLESHOOTING

Sun 4300 Address Decoding
Continued
Sun-4300 9U Memory Board Addressing, 1st 24M bytes
ADDRESS (Dec)

CPU-26

ADDRESS (Hex)

BANK

BYTE

SOCKET

8-12MB
8-12MB
8-12MB
8-12MB

800000-bfffff
800000-bfffff
800000-bfffff
800000-bfffff

OL
OL
OL
OL

0
1
2
3

U1600
U1601
U1602
U1603

12-16MB
12-16MB
12-16MB
12-16MB

cOOOOO-ffffff
cOOOOO-ffffff
cOOOOO-ffffff
cOOOOO-ffffff

OH
OH
OH
OH

0
1
2
3

U1604
U1605
U1606
U1607

16-20MB
16-20MB
16-20MB
16-20MB

1000000-13fffff
1000000-13fffff
1000000-13fffff
1000000-13fffff

1L
1L
1L
1L

0
1
2
3

U1700
U1701
U1702
U1703

20-24MB
20-24MB
20-24MB
20-24MB

1400000-17fffff
1400000-17fffff
1400000-17fffff
1400000-17fffff

1H
1H
1H
1H

0
1
2
3

U1704
U1705
U1706
U1707

24-28MB
24-28MB
24-28MB
24-28MB

1800000-1 bfffff
1800000-1 bfffff
1800000-1 bfffff
1800000-1 bfffff

2L
2L
2L
2L

0
1
2
3

U1800
U1801
U1802
U1803

28-32MB
28-32MB
28-32MB
28-32MB

1cOOOOO-1 ffffff
1cOOOOO-1 ffffff
1cOOOOO-1 ffffff
1cOOOOO-1ffffff

2H
2H
2H
2H

0
1
2
3

U1804
U1805
U1806
U1807

Field Engineer Handbook

TROUBLESHOOTING

12/90

Sun 4300 Address Decoding
Continued
Sun-4300 9U Memory Board Addressing, 2nd 24M bytes
ADDRESS (Dec)

BANK

BYTE

SOCKET

32-36MB
32-36MB
32-36MB
32-36MB

2000000-23fffff
2000000-23fffff
2000000-23fffff
2000000-23fffff

3L
3L
3L
3L

0
1
2
3

U1900
U1901
U1902
U1903

36-40MB
36-40MB
36-40MB
36-40MB

2400000-27fffff
2400000-27fffff
2400000-27fffff
2400000-27fffff

3H
3H
3H
3H

0
1
2
3

U1904
U1905
U1906
U1907

40-44MB
40-44MB
40-44MB
40-44MB

2800000- 2bfffff
2800000-2bfffff
2800000-2bfffff
2800000- 2bfffff

4L
4L
4L
4L

0
1
2
3

U2000
U2001
U2002
U2003

44-48MB
44-48MB
44-48MB
44-48MB

2cOOOOO-2ffffff
2cOOOOO-2ffffff
2cOOOOO-2ffffff
2cOOOOO-2ffffff

4H
4H
4H
4H

0
1
2
3

U2004
U2005
U2006
U2007

48-52MB
48-52MB
48-52MB
48-52MB

3000000-33fffff
3000000-33fffff
3000000-33fffff
3000000-33fffff

5L
5L
5L
5L

0
1
2
3

U2100
U2101
U2102
U2103

52-56MB
52-56MB
52-56MB
52-56MB

3400000-1 ffffff
3400000-1 ffflff
3400000-1 ffflff
3400000-1 ffffff

5H
5H
5H
5H

0
1
2
3

U2104
U2105
U2106
U2107

Technical Volume II

ADDRESS (Hex)

CPU-27

TROUBLESHOOTING

12/90

Sun 4400

Self-Test Error Codes
LEOs

0

•
•
0

7

SYSTEM ACTIVITY

PROBLEM BOARD

LED Loop Test (Walking LEOs)

CPU Board

0 0 0 0 0 00

SCC Write-Read Test

CPU Board

0000000

Initali.ze SCC UART

CPU Board

00000 0 0

0 .000000

'Boot PROM Selftest' Message

CPU Board
(Boot PROM)

•

.000000

EPROM Checksum Test

CPU Board

0 . 0 0 0 00

Context Register Write-Read Test

CPU Board (MMU)

Region Map Test(s)
Segment Map Test(s)

CPU Board
CPU Board (MMU)

• • • 00000

Page Map Test(s)

CPU Board (MMU)

0

Software Traps Test

CPU Board

0

. 0 . 0 0 0 00
0 • • 0 0 0 00

0 0 . 00 00

.00.0000

Interrupts Register Test

CPU Board

0 . 0 . 0000

Software Interrupts Test

CPU Board

• . 0 . 0000
0 o •• 0000

Bus Error Register Test

CPU Board

• 0 ••
• • ••

0000

MIC Registers Write-Write-Read Test CPU Board
MIN Registers Write-Write-Read Test CPU Board
MIC Trace Test

CPU Board

TOO Interrupt Test

CPU Board

0 0 00 . 0 0 0

Video Memory Test

CPU Board

.000.000

Limited Main Memory Test(s)

Memory Board

0 .00.000

EEPROM Test(s)

CPU Board (MMU)

••

MMU Read/Write Test(s)

CPU Board (MMU)

Timeout Test(s)

CPU Board

Size Error Test

CPU Board

0 • • • 0000
0000

00.000

0 0.0 .000
.0 .000
• 0
0 •• 0 .000

ECC Memory Test(s)

Memory Board

CPU Cache Tag RAM Test(s)

CPU Board

0 0 0 • • 000

CPU Cache Data RAM Test(s)

CPU Board

.00 • • 000

CPU Cache Read/Write Hit-Miss
Test(s)
Block Copy Test(s)

(CC

•

•• 0 .000

0.0 • • 000

CPU Board
gatE! array)
CPU Board

VME Loopback Test

CPU Board

00 • • • 000

10C Tag RAM Test(s)

CPU Board

•

10C Data RAM Test(s)

CPU Board

10C Functional Tests
Read/Write/Flush

CPU Board

Main Memeory Tests (ECC On)

CPU Board

•

.0 • • 000

0 • • • 000

0 ••• .000

• ••• . 0 0 0
CPU-28

Field Engineer Handbook

TROUBLESHOOTING

12/90

Sun-41E
8elf-Test Error Codes
o

LEOs

SYSTEM ACTIVITY

7

(converging pattern) Aux/IO LED Register Test
a a a a a a O.

EPROM Checksum Test

0 0 0 0 0 0 . 0 Context Register Test
0 0 0 0 00 • •

Segment Map Write-Write-Read-Read Test

0000 0.00

Segment Map Address Test

0000 0.0.

Segment Map 3-Pattern Test

0000 0 •• 0

Page Map Write-Write-Read-Read Test

0000 0 • • •

Page Map Address Test

0000 .000

Page Map 3-Pattern Test

0000 . 0 0 .

Software Trap Test: Levels Ox80-0xFF

0000 . 0 . 0

Interrupt Register Test

0000 .0 ••
0000
0000
0000
0000

••
•• O •

00

••

.0

•• ••

Software Interrupt Test
TOO SRAM Write-Write-Read-Read Test
TOO SRAM Address Test
TOO SRAM 3-Pattern Test
TOO Interrupt Test

000. 0000

Probing for ECC and Main Memory
Limit Memory Test: End of Megabyte OxOOOOOOO4

000. 000.

MMU Read Access/Modified Bit Test

000. 00.0

MMU Write Access/Modified Bit Test

0 0 0 . 00 • •

MMU Write to Write-Protected Page Test

000. 0.00

MMU Read from Write-Protected Invalid Page Test

0 0 0 . O. O.

MMU Read from Writeable Invalid Page Test

0 0 0 . O. . 0

MMU Write to Write-Protected Invalid Page Test

0 0 0 . O.

••

000. .000

MMU Write to Writeable Invalid Page Test
Main Memory Non-Existent PhYSical Address Read
Timeout Test

000. .00.

Main Memory Invalid Physical Address Read Timeout Test

000. .0.0

Control Space Timeout Test

000. .0 ••

Range Error Test

0 0 0 . • • 00

Cache Data RAM Write-Write-Read-Read Test

000. •• 0.

Cache Data Ram Address Test

Technical Volume II

CPU-29

TROUBLESHOOTING

12/90

Sun-4/E
Self-Test Error Codes - Continued
LEOs

0

00

o.

00

o •

SYSTEM ACTIVITY

7

•• . 0
•• ••

Cache Data RAM 3-Pattern Test
Cache Tag RAM Write-Write-Read-Read Test

00 . 0 00 00 Cache Tag RAM Address Test
00 . 0 00

o.

Cache Tag RAM 3-Pattern Test

00 . 0 00 . 0 Parity No Fault Test
00 • 0

00

••

Parity Error Detection and Interrupt Test

00 . 0

o.

00

Parity Error Detection Without Interrupt Test

00 • 0

o •

••

ECC (Mernory Ox4MB) Test: Megabyte OxOOOOOOO4
(option)

00 • 0

••
••

00 • 0

o •
o •
o •

00 • 0

o •

00 • 0

•• 00
•• o •
•• . 0
•• • •

00 •

0

00 • 0
00 •

0

00 •

0

00
00
00

••
••
••

CPU-30

••
••

00 00
00

o.

ECC Single Error Correction Test (option)
ECC Single Error Correction (With Interrup On) (option)
Syndrome, Diagnostic & Physical Address Register Test
(option)
ECC Double Bit Error Correction Test (option)
Main (Memory Ox4MB) Test: Megabyte OxOOOOOOO4
VME Mail Box Test
VME Interrupt Register Test
VME A32 Map Register Test
VME Slave Map Register Test
VME Loopback and DVMA Write/Read (Type 3,32-Bit)
Test

0 0 . 0 VME Loopback and DVM A Write/Read (Type 2,32-Bit)

Test

Field Engineer Handbook

TROUBLESHOOTING

DISK

TROUBLESHOOTING

12/90

Disk
DISK DRIVES
ESMD
Hitachi DKS15-1 0 . . . . . . . . . . . . . . . . . . . . . . . ..
Fujitsu M2361 A . . . . . . . . . . . . . . . . . . . . . . . . . ..
NEC 02363 .... ........... ...... ..... ....

2
3
S

DISK CONTROLLERS
ESDI
Emulex MD21

...........................

11

ESMD
Xylogics 450/451 .........................
Xylogics 7053 . . . . . . . . . . . . . . . . . . . . . . . . . . ..

17
19

ISP
ISP-SO Disk Controller (lPI2) . . . . . . . . . . . . . . . . ..

Field Engineer Handbook - Technical Volume II

24

12/90

TROUBLESHOOTING

This page intentionally left blank.

DISK-2

Field Engineer Handbook

12/90

TROUBLESHOOTING

Hitachi DK815-1 0
Status LEOs in Status Mode
Mode Status
Switch LED 0
Set To
0
0 Unit
Ready

Status
LED 1

Status
LED 2

Seek
Error

Reserved
Unit
Reserved Unit
Selected 0
Selected 1 *
1*
0

Control
Check

Index
Check

Transition
Check

Capable
Check

MultiHead
Check

Initial
Seek
Check

Overshoot
Check

Access
Timeout
Check

Address
Over

0

1

Write On
Read
Check

0

2

InterHDA
Sequence face
Check
Check

0

3

Voltage
Check

* Dual

Thermal MPU
Alarm
Check

Status
LED 3

Status
LED 4

Status
LED 5

Servo
Data
Encode/ Offtrack
Decode
Check

port option only

Reference
DK815-10 Winchester Disk Drive OEM Manual, 875-1000-XX.

Technical Volume II

DISK-3

TROUBLESHOOTING

12/90

Fujitsu M2361 A
Drive Status and State
Table 1 describes the drive state information indicated by two
7-segment LEOs in accordance with the position of the toggle
State Switch. The Write/Read Check State, Access State, and
DE Sequence State are described on the following pages.
STATE SWITCH
POSITION

~
LED

BIT
1

UPPER (ST 0)
WRITE/READ
CHECK STATE

CENTER (ST 1)
ACCESS
STATE

LOWER (ST 2)
DE SEQUENCE
STATE

Index Check

DE Sequence
Check

DE Sequence
Latch 1

2

Control Check

Access Timeout DE Sequence
Latch 2
Check

4

Multi-Head
Check

Over Shoot
Check

DE Sequence
Latch 4

8

Head Short
Check

Rezero Mode
Latch

Hall Alarm

1

Write Current
on Read Check

Servo Latch

Motor At Speed

2

Write Transition
Check

Linear Mode
Latch

Inhibit DE
Seq. Recycle

4

Delta I
Write Check

Control Latch

Unit Ready

8

Servo Off-Track Wait Latch

LP1

LP2

Access Busy

Table 1. State Switch and State Indicators
Use the information from Table 1 in conjunction with the flow charts in
Chapter 5 of the Fujitsu M2361A Mini-Disk Drive Customer Engineering
Manual, 800-1423, to determine the failing assembly. This information
can also beLJsed to troubleshoot the FujitsLJ M2351 A disk drive.

OISK-4

Field Engineer Handbook

12/90

TROUBLESHOOTING

Fujitsu M2361 A
Write/Read Check State (ST 0)
The Write/Read Check State indicates fault status during a Write or
Read operation. When a fault status occurs in the drive, the Fault
signal in the Unit Status is issued as a summary to the controller. The
controller issues a Fault Clear Signal to clear the Write/Read Check
State.
Index Check
(Status 0)

The Index signal not detected where it
should be or is detected where it should
not be during a Read/Write operation.

Control Check
(Status 1)

Caused by the following conditions:
1. Write and Read Gate are issued at
the same time.
2. Write operation during offset mode
3. Write Gate issued in the write protect
mode.

Multi-Head Check
(Status 2)

Two or more head ICs are selected
simultaneously.

Head Short Check
(Status 3)

Abnormal current sensed in the Write
Select line during a write operation.

Write Current on Read Ck.
(Status 4)

Write current sensed during a read
operation.

Write Transition Check
(Status 5)

Write current is not switched for writing
data. The detection continues from
byte-8 after Write Gate is true until the
end of the Write operation.

Delta I Write Check
(Status 6)

Abnormal write current sensed in the
inner head or outer head.

Servo Off-Track
(Status 7)

Indicates the following fault conditions.
1. The head is +/-100 micro-inches off
the desired track during the Write/
Read operation.
2. Write/Read Gate is received by the
drive during not On Cylinder status,
Heads in Motion, or Seek Error.

Technical Volume II

DISK-5

TROUBLESHOOTING

12/90

Fujitsu M2361 A
Access State (ST 1)
The Access State indicates the access status of the head in Seek and
RTl operation and the Start/Stop sequence of the spindle motor.
DE Sequence Check
(Status 0)

An Abnormal start/stop sequence of the
DE occurred in the drive. One of the
following errors occurred as DE SEQ
advanced:
1. Initial State Good (Motor At Speed
and Hall Alarm not present), Does
not result in State 1.
2. Run State Good (not Hall Alarm and
Motor At Speed are sent out). Can
not be obtained for approximately 40
seconds in State 3.
3. Run State Good goes off during State
6.
Cannot be cleared by the Fault Clear
Switch on the operator panel or the
Fault Clear signal on the interface.
Cleared by stopping rotation of the
spindle.
Latches 4, 2 and 1 of DE SEQ
represent the DE SEQ status shown in
Table 2.

Access Time-Out Check
(Status 1)

During an RTl or Seek operation, On
Cylinder failed to appear within 250 ms
+/- 30% after Access Start. Cleared
by an RTl operation.

Overshoot Check
(Status 2)

Heads go past the desired track during
a Seek or RTl operation, or go into the
Guard Band or ID Position during a Seek
operation. The heads are moving at an
abnormal speed during the RTl
operation. Cleared by an RTl
operation.

Rezero Mode Latch (Sta. 3)
Servo Latch (Status 4)
Linear Mode Latch (Sta. 5)
Control Latch (Status 6)
Wait Latch (Status 7)

These latches observe the sequence of
seek and RTl operations. When an
error occurs during a seek or RTl, the
contents of these latches is frozen.
Cleared by RTl operation.
The relationship between Access State
and the contents of the latches is shown
in Table 3.

DISK-6

Field Engineer Handbook

TROUBLESHOOTING

12/90

Fujitsu M2361 A
DE Sequence Latches
STATE
No.

LATCH
4

LATCH
2

LATCH
1

0

0

0

0

Wait status

1

0

0

1

Start/Stop switch on the
operator panel is set to Start.

3
2

0

1

Spindle motor starts rotating.

0

1
1

0

6

1

1

0

Sequence Rezero starts
approximately 40 seconds after
State 3.
Sequence Rezero is completed
and seek operation is possible.

7

1

1

1

DE Stop Sequence State
results and the head begins to
return to the home position (Go
Home).

5

1

0

1

Go Home operation is
completed and the spindle
motor stops rotating.

4

1

0

0

Approximately 40 seconds
following State 5. (Returns to
State 0).

STATUS

Table 2. Contents of DE Sequence Latches

Technical Volume II

DISK-?

TROUBLESHOOTING

12/90

Fujitsu M2361 A
DE SEQ Latches
1.2. and 4

Indicates Start/Stop status of DE.
See Table 4.

Hall Alarm

All output signals from the hallelements used to detect the pole
position of the rotor in the spindle
motor are high or low level
simultaneously.

Motor At Speed

Spindle motor rotating at 3,600 RPM
+/-2%.

Inhibit DE Sequence

Recycle Run State Good goes false while
the DE Sequence Latch is in State 7.
Stop sequence of the DE may be
inhibited hereafter. Cleared by switching
Off the drive power or pushing the
Start switch to Off.

Unit Ready

Drive has reach the rated rotational
speed and heads are positioned on
track.

Access Busy

Heads are in motion performing Seek,
RTZ, or Offset operation.

Table 3. Description of DE Sequence State (ST2) Latches

LATCHES
Rezero
Mode

STATE

Servo

Linear
Mode

Control

Wait

0

0

0

0

1

Wait State

0

0

0

0

0

State BTZ

1

0

0

0

0

Move In

1

0

0

1

0

Turn Around

1

0

1

1

0

Move Out

0

0

1

1

0

RTZ Linear Mode

0

1

1

1

0

On Track

0

1

0

1

0

Accelerate

0

1

0

0

0

Decel.erate

0

1

1

0

0

Seek Linear Mode

0

1

1

1

0

On Track

Mode
Reset

RTZ

Seek

Table 4. Access States

DISK-8

Field Engineer Handbook

TROUBLESHOOTING

12/90

NEC 02363 Disk Drive
Fault Line Error Codes
STATE
Power On Initialize
Stop Mode
Start Wait
Motor Initiating

Motor Speed Up

Motor Speed OK

Lock Servo PLO

Recalibrate Out

Technical Volume II

STATE FAULT
1
1
1
2
1
4
2
1
3
1
4
1
4
3
4
4
5
1
5
2
5
3
1
6
2
6
6
3
7
1
7
2
7
4
7
5

8
8
8

1
4
5

8
8
8
8
8
8
8
8

6
7
8
9
A
B
C
D

DESCRIPTION
Voltage fault
ROM fault
Fault latch
Voltage fault
Voltage fault
Voltage fault
Motor not up to speed
No rotation
Voltage fault
Motor speed too slow
Motor speed too high
Voltage fault
Motor speed loss
Motor over speed
Voltage fault
Motor speed loss
Lost index
Inner guard band (1GB)
not found
Voltage fault
Lost Index
Outer Guard Band (OGB)
not found
No N linearity found
No half track found
No Q linearity found
No difference found
Not at target velocity
Too slow not found
Over shoot check
Overshoot check (Time out)

DISK-9

TROUBLESHOOTING

12/90

NEG 02363 Disk Drive
Fault Line Error Codes - Continued
STATE

STATE FAULT
DESCRIPTION
1
9
Voltage fault
4
9
Lost index
OGB not found
9
5
Recalibrate In
9
No linearity found
9
9
C
Over shoot check
D
Over shoot check (Time out)
9
Voltage fault
A
1
2
Loss of motor speed
A
Ready (On Cylinder)
Motor speed over
A
3
A
4
Lost index
A
Off track
C
B
1
Voltage fault
B
4
Lost index
B
No difference=Q found
9
Move Out
B
C
Over shoot check
B
D
Over shoot check (Time out)
8
E
Over travel (OG8)
B
F
Over travel (1GB)
Interface Check
1
Over cylinder
C
Tag 1 while not ready
C
3
D
1
Voltage fault
4
Lost index
D
D
No difference=Q found
9
Move In
D
Over shoot check
C
D
D
Over shoot check (Time out)
E
Over travel (OGB)
D
D
F
Over travel (1GB)

DISK-10

Field Engineer Handbook

TROUBLESHOOTING

12/90

NEC 02363 Disk Drive
Fault Line Error Codes - Continued
STATE

Seek Calibration

Fault Detected

DESCRIPTION
STATE FAULT
1
Seek unsuccessful
E
Seek speed too high'
2
E
E
Seek speed too low'
3
E
4
Not PLO good in offset
E
Off track in offset seek
5
Offset command while
6
E
Not on Cylinder state
E
7
RTZ unsuccessful'
Protect violation or read. write
F
1
2
(Unit not ready or non on
F
cylinder). write
F
Write clock fault
3
F
4
Off track write
F
5
Write. MARS unsafe
Read.MARS unsafe
F
6

'These "errors" do not send a "Seek Error" report to the system.
They only appear on the Status Display.

Technical Volume II

DISK-11

TROUBLESHOOTING

12/90

MD21 Disk Controller
Extended Sense Key Codes
HEX
ERROR
CODE
No Sense
00

01

Recovered
Error

02

Not Ready

03

Media
Error

04

Hardware
Error

05

Illegal

06

Unit
Attention

08

Reserved

DESCRIPTION
No Sense Key information is reported for the
designated LUN. This code occurs for a
successfully completed command.
The last command was completed successfully, with some recovery action performed
by the Target.
The addressed LUN cannot be accessed.
Operator intervention may be required.
The command terminated with a nonrecoverable error condition probably caused by a
flaw in the media or by an error in the
recorded data.
A nonrecoverable hardware error (e.g.,
controller failure, device failure, parity error,
etc.) was detected while the Target was
performing the command or while the Target
was performing a self-test operation.
There was an illegal parameter in the
Request command or in the additional
required parameters supplied as data for
some related commands. If the error is
detected in the Command Descriptor Block,
the controller will not alter the Media.
The addressed LUN has been reset. This
error is reported the first time any command
is issued after the condition is detected. The
requested command is not performed. This
condition is cleared when the next command
is issued by the same Initiator. UNIT ATTENTION is reported to all SCSI devices that
subsequently issue commands to the LUN.
This key is reserved.

Note: MD21 errors are reported in the form:
sd: sense key = (extended sense key code)
error = (extended sense error code)

DISK-12

Field Engineer Handbook

12/90

TROUBLESHOOTING

MD21 Disk Controller
Extended Sense Key Codes - Continued
HEX
CODE

ERROR

07

Data Protect

08
09

Reserved
Vendor
Unique

OA

Copy/Compare
Aborted

OB

Aborted
Command

OE

Miscompare

DESCRIPTION
A write operation was attempted on a writeprotected device.
This key is reserved.
A Vendor Unique error condition occurred.
The corresponding nonextended error class
and code are specified in Byte 12 of the
Extended Sense Byte.
A COPY or COMPARE command was
aborted because an error condition was
detected on the source and/or destination
device.
The Target aborted the command. The
Initiator may recover by trying to execute
the command again.
Used by the Verify command to indicate
the source data did not match the data read
from the disk.

References
MD21/S2 Disk Controller Technical Manual and the Emulex SCSI
Disk Controller Programming Reference Manual. There are no Sun
part numbers for these manuals.

Technical Volume II

DISK-13

TROUBLESHOOTING

12/90

MD21 Disk Controller
Nonextended Sense Error Code
HEX
CODE

ERROR

00

No Sense

02

No Seek
Complete
Write Fault

03
04
05
06
10
11
12
13
14
15

17

18

DISK-14

Drive Not
Ready
Drive Not
Selected
No Track

DESCRIPTION
The controller detected no error during
execution of the previous command.
The controller could not seek to the
specified logical block within an allotted time.
The controller determined that the Attention
line from the disk drive was asserted during
a write operation.
The disk drive is not ready.

The drive associated with the specified LUN
could not be addressed.
The controller could not rezero the disk
drive.
ID Field CRC
The sector ID field could not be read after
the number of retry attempts specified in the
Error
MODE SELECT command.
Uncorrectable
A block could not be written or read after
the number of retry attempts specified in the
Data Error
MODE SELECT command.
ID Field Addr
The controller could not locate the address
Mark not Found mark for a sector leader.
Data Addr
The controller could not locate the address
Mark not Found mark for a sector header.
The block sequence is improper. or a block
Block Not
Found
is missing.
A miscompare occurred between the
Seek Error
cylinder address of the data header and the
address specified in the CDB of the
command.
Recovered
The controller encountered an error. It
Read Error
recovered the data using retries.
(with retries)
Recovered
The controlier encountered an error. It
Read Error
recovered the data using ECC correction.
(with ECC)

Field Engineer Handbook

12/90

TROUBLESHOOTING

MD21 Disk Controller
Nonextended Sense Error Code - Continued
HEX
ERROR
CODE
19
Defect List
1A

Parameter
Overrun

1C

Primary Defect
List Not Found
Compare
Error

10

20
21
22
24

Invalid
Command
Invalid Block
Address
Illegal Function
for Device Type
Illegal Field
In CDB

25

Invalid LUN

26

Illegal Field in
Parameter List

27

Write
Protected
Medium
Change

28

Technical Volume II

DESCRIPTION
The controller encountered an error while
accessing one of the Defect Lists.
The Parameter List Length specified in the
CDB by the Initiator is too large for the
controller.
The controller could not locate the
manufacturer's defect list.
One or more bytes did not compare when
the VERIFY or READ BUFFER command was
issued.
The Initiator issued a command that cannot
be executed, or is not applicable.
The addressed block was not valid.
The addressed LUN is unable to perform the
requested function.
A field in the Command Descriptor Block
is reserved and contains a value other than
zero or, the value in the field is incorrect...The LUN specified in the Command
Descriptor Block or SCSI IDENTIFY message
is not support by the controller.
A field in the Parameter List is reserved and
contains a value other than zero or the
value in the field is incorrect.
The disk is write protected. The outstanding
WRITE command is aborted.
When the controller detects a media
changed condition, it sets the Sense Key/
Error Code to UNIT ATTENTION/MEDIA
CHANGED (06h/28h). A media changed
condition occurs when the controller detects
a drive offline condition, and then detects the
drive come online.

DISK-15

TROUBLESHOOTING

12/90

MD21 Disk Controller
Nonextended Sense Error Code - Continued
HEX
CODE

ERROR

29

Power Up or
Reset

2A

Mode Select
Changed

31

Format Failed

32

No Defect
Spare Location
Available

40

RAM Failure

43

Message
Reject

DISK-16

DESCRIPTION
The controller was reset by a SCSI Bus
Reset, Bus Device Reset Message, or Power
On Reset condition. After the controller
detects the condition, it reports this error
when the first command (except the INQUIRY
command) is issued to it. The controller
clears this condition when the next command
is issued to it by the same Initiator, and
reports the UNIT ATTENTION Sense Key to
all SCSI devices that subsequently issue a
command to it.
The MODE SELECT parameters for this
device have been changed by another
Initiator and may affect current operations.
After the controller detects the condition, it
reports the error when the first command
(except the INQUIRY command) is issued to
it. The controller clears this condition when
the next command is issued to it by the
same Initiator. The controller reports the
UNIT ATTENTION Sense Key to all SCSI
devices that subsequently issue a command
to it.
The FORMAT UNIT command encountered
an error while attempting to access on the
defect lists.
No alternate tracks remain on the addressed
LUN. This error condition may occur during
the processing of a FORMAT UNIT or
REASSIGN BLOCK command.
The controller detected a RAM memory error
during a SEND DIAGNOSTIC text operation.
The Initiator responded with a MESSAGE
REJECT to a message sent by the controller.

Field Engineer Handbook

12/90

TROUBLESHOOTING

MD21 Disk Controller
Nonextended Sense Error Code - Continued
HEX
CODE

44
45
47

48
49

ERROR

DESCRIPTION

SCSI Hardware/ The SCSI Firmware detected an internal
Firmware Error firmware or hardware error and was unable
to complete the current command.
SelectiReselect The SCSI firmware detected a timeout error
Failed Error
while attempting a Selection or Reselection.
Parity Error
A parity error occurred on the SCSI Bus and
the controller was unable to recover the
data.
Initiator
Detected Error

The Initiator sent an INITIATOR DETECTED
ERROR message and the controller was
unable to recover from the error.
Inappropriate/
The Initiator sent an inappropriate or
Illegal Message illegal SCSI Message to the controller.
Error

Technical Volume II

DISK-17

12/90

TROUBLESHOOTING

Xylogics 450/451 Disk Controller
Completion Code Description
CODE

TYPE

00
01
02
03
04
05
06
07
08,09
OA
OB, OC
OD
OE
OF, 10, 11
12
13
14
15
16
17
18
19
1A
1B
1C

Status
Hard
-----Hard
Hard
Hard
Hard
Hard
-----Hard
-----Hard
Hard

10

------

1E
1F
20
21
22, 23, 24
25

Hard
Soft
Hard
Hard

-----Hard
Soft
Hard
-----Hard
Hard
Hard
Hard
Hard
Hard
Hard

-----Hard

DEFINITION
Successful Completion
Interrupt Pending
Reserved
Busy Conflict
Operation Timeout
Header Not Found
Hard ECC Error
Illegal Cylinder Address
Reserved
Illegal Sector Address
Reserved
Last Sector Too Small
Slave ACK Error (Non-Existent Memory)
Reserved
Cylinder and Head/Header Error
Auto Seek Retry Successful
Write Protect Error
Reserved
Drive Not Ready
Sector Count Zero
Drive Faulted
Illegal Sector Size
Self Test A
Self Test B
Self Test C
Reserved
Soft ECC Error
Soft ECC Error Recovered
Illegal Head Error
Disk Sequencer Error
Reserved
Seek Error

Note: Xylogics 450/451 errors are reported in the form:
"xy: error (Completion Code) cmd (Command)".

DISK-18

Field Engineer Handbook

12/90

TROUBLESHOOTING

Xylogics 450/451 Disk Controller
Command Description
HEX VALUE

COMMAND

0

No Operation (NOP)

1

Write

2

Read

3

Write Track Headers

4

Read Track Headers

5

Seek

6

Drive Reset

7

Write Format

8

Read Header, Data, and ECC

9

Read Drive Status

A

Write Header, Data, and ECC

B

Set Drive Size

C

Self Test

D

DMA Test

E

Maintenance Buffer Load

F

Maintenance Buffer Dump

Note: Xylogics 450/451 errors are reported in the form:
"xy: error (Completion Code) cmd (Command)".

Technical Volume II

DISK-19

TROUBLESHOOTING

12/90

Xylogics 7053 Disk Controller
Completion Code Type Descriptions
CODE
No Action/Status Only
(00)
Non-retryable Programming
Errors
(10-20)
Successfully Recovered
Soft Errors
(30-33)

Hard Errors/Retry
(40-48)

Hard Errors - Reset/Retry
(60-64)
Fatal Hardware Error
(70-71)

DESCRIPTION
Status only. These completion codes
require no action.
This group of errors is usually
encountered while debugging drivers.
They should not occur in a normal
operating system environment.
Status only. If some errors recur often,
the operating system should try to map
out the sectors involved. Allowing
these errors to recur degrades
performance.
Transfer failed. Retry the operation. If
several retries fail, manual intervention
is required or the operating system may
crash.
Transfer failed. Software should issue
a Drive Reset command to the drive
in use before retrying the operation.
Hardware failed. Manual intervention
or a Controller Reset may be the only
recovery approach.
Soft ECC

Miscellaneous Errors
(80)
Requires Manual Intervention Manually remove the write-protection.
(90)

Notes
1. Xylogics 7053 errors are reported in the form:
"xd: error (Completion Code) cmd (Command)"
2. Reference the Model 7053 Users Manual, 875-1013-01.

DISK-20

Field Engineer Handbook

12/90

TROUBLESHOOTING

Xylogics 7053 Disk Controller
Completion Code Descriptions
CODE

COMPLETION CODE

00

Successful Completion

10

Illegal Cylinder Address

11

Illegal Head Address

12

Illegal Sector Address

13

Count Zero

14

Unimplemented

15
16
17
18
1A
1B
1C

Illegal Field Length 1
Illegal Field Length 2
Illegal Field Length 3
Illegal Field Length 4
Illegal Field Length 6
Illegal Field Length 7
Illegal Scatter/Gather
Length

Technical Volume II

DESCRIPTION
Not an error. The IOPB is
complete.
Host software specified a cylinder
address greater than the maximum
number specified in the last Set
Drive Parameters command for
this drive.
Host software specified a head
address greater than the maximum
head address specified in the last
Set Drive Parameters command
for this drive.
Host software specified a sector
address greater than the maximum
sector number specified in the last
Set Drive Parameters command
for this drive.
Host software issued the 7053 an
IOPB that required a count, but
the count was zero. Read, Write,
and Format commands require a
valid count.
Occurs on all reserved commands.
Refer to Model 7053 User's Manual

The linked list specified a number of
words to transfer that does not
agree with the amount of data
contained in the requested number
of sectors for transfer.

DISK-21

TROUBLESHOOTING

12/90

Xylogics 7053 Disk Controller
Completion Code Descriptions - Continued
CODE

COMPLETION CODE

10

Not Enough Sectors
Per Track

1E

Next IOPB Alignment
Error

1F

Scatter/Gather Address
Alignment Error
Scatter/Gather with
Auto ECC Error

20

30

Soft ECC Corrected

31

ECC Error Ignored

32

Auto Seek Retry
Recovered

33

Soft Retry Recovered

40

Hard Data ECC Error

41

Header Not Found

DISK-22

DESCRIPTION
The format routine was unable to
format since too few sectors were
actually available on the track.
The Next IOPB Address did not start
on a 16-bit boundary. The 7053
does not execute the NIOPB.
A Scatter/Gather address did not
start on a 16-bit boundary.
A Scatter/Gather operation resulted
in a correctable ECC error. Due to
Scatter/Gather boundaries, the 7053
did not automatically correct the
error, but reverted to ECC Mode O.
The 7053 detected and corrected
one or more ECC errors during a
disk read in ECC Mode 2.
The 7053 detected, but ignored, an
ECC error (during a Read
command in ECC Mode 1) and
continued the transfer.
The 7053 completed the transfer
successfully. During the transfer, it
recovered from an error by
resetting the drive.
The 7053 encountered an error
while executing this command. A
retry due to RBC being set or a
zero latency read was successful.
The 7053 detected a hard data ECC
error in the data field during a Read
command. Retry the previous Read
operation.
The 7053 cannot find the requested
sector. The controller searches for
one disk revolution plus one sector
to locate the header.

Field Engineer Handbook

12/90

TROUBLESHOOTING

Xylogics 7053 Disk Controller
Completion Code Descriptions - Continued
CODE

COMPLETION CODE

42

Drive Not Ready

43

Operation Timeout

44

VMEDMA Timeout

45

Disk Sequencer Error

46

FIFO Parity

47

Dual Port Busy

48

Header ECC Error

49

Read Verify

4A

Fatal VMEDMA Error

4B

VMEbus Error

Technical Volume II

DESCRIPTION
The selected drive is not ready, but
not faulted. Issue a Drive Reset.
Causes include:
1. Drive not up-to-speed.
2. Drive hardware error.
3. Bad or improperly connected
cable(s).
4. Specified Unit Number drive is
not connected to the 7053.
The 7053 did not complete the IOPB
within a two second timeout period.
The DMA controller did not complete
its task within the allotted time limit.
One reason could be that memory
did not respond in time.
The disk sequencer did not
complete its task within the allotted
time limit. The 7053 cannot send
or receive the appropriate Signals
from the selected drive.
The transfer failed. The 7053
detected a FIFO parity error.
The 7053 timed out while waiting for
the port on a dual ported drive.
The timeout is two seconds.
The 7053 found a header match,
but the Header ECC did not
compare.
Data read from the disk did not
match data read from memory.
The VMEDMA stopped for no
apparent reason. The count for
the address overflowed and there
was no bus error.
The VME BERR· signal was
asserted while the 7053 was bus
master.

DISK-23

12/90

TROUBLESHOOTING

Xylogics 7053 Disk Controller
Completion Code Descriptions - Continued
CODE

COMPLETION CODE

60

Drive Faulted

61

Header Error/Cylinder

62

Header Error/Head

63

Drive Not On-Cylinder

64

Seek Error

70

Illegal Sector Size

71

Firmware Failure

80

Soft ECC Error

DISK-24

DESCRIPTION
The selected drive is faulted. Issue
a Drive Reset.
The cylinder address did not match
during a sector search. Check the
cylinder address and retry the
operation.
The head address did not match
during a sector search.
At some point during the transfer,
the 7053 expected the drive to be
on-cylinder, and it was not.
The disk drive reported a seek
error.
The disk drive sector size is not
large enough to hold the header,
data, and specified field lengths.
Flag settings or counter values are
inconsistent with the firmware
routines being executed.
The 7053 detected a correctable
error in the data field of the current
sector during a Read operation in
ECC Mode O. Software must
perform the final correction.

Field Engineer Handbook

12/90

TROUBLESHOOTING

ISP-80 Disk Controller (IPI-2)
Self-Test Error Codes
LED 7 lights to indicate a failed self-test
7

LEDs

o

SYSTEM ACTIVITY

000000.0

EPROM Checksum Test

000000 ••

LED Register Test

00000.00

SCC Port A Register Test

00000.0.

SCC Port B Register Test

00000 •• 0

SCC Port A Internal Loopback Test

00000 •••

SCC Port B Internal Loopback Test

0000.0.0

Exec RAM Inverse Test

0000.0 ••

Exec RAM Address Test

0 0 0 0 • • 00

Exec RAM 3-Pattern Test

0000 •• 0.

Exec RAM March Test

0000 ••• 0

Exec RAM Byte Allignment Test

000.0000

cia

000.000.

Read-Ahead Buffer Inverse Test

000.00.0

Read-Ahead Buffer Address Test

Register Test

000.00 ••

Read-Ahead Buffer 3-Pattern Test

000.0.00

Read-Ahead Buffer March Test

000.0 •• 0

VME Register Test

000.0 •••

IPI LCA Configuration Test

000 • • 000

IPI Register Test

000 • • 00.

IPI DMA Loopback Test

000 • • 0.0

IPI Quick Command Sequence Loopback Test

000 • • 0 ••

IPI Bus Control Sequence Loopback Test

000 • • • • 0

Bus Error Interrupt Test

000 • • • • •

Address Error Interrupt Test

00.00000

SCC Interrupt Test

00.0000.

cia

00.000.0

Read-Ahead Buffer Parity Error Interrupt Test

Interrupt Test

00.000 ••

IPI Interrupt Test

00.00.00

Diagnostic Engineering Monitor (DEMON)

Technical Volume II

DISK-25

TROUBLESHOOTING

12/90

ISP-80 Disk Controller
Diagnostic Engineering Monitor
The Diagnostic Engineering Monitor (DEMON) is entered
when the Diag/Norm switch is in the Diag position.
SYSTEM ACTIVITY
Enters DEMON mode when Self-test is completed.

Self-test output is monitored by connecting the ISP-80
controller to a terminal set to 9600 baud, 8 data bits, no
parity, and 1 stop bit. The ISP-80 Controller serial port is a
25-pin, dual in-line, header-type connector.
Since Sun does not make a cable that connects the
ISP-80 controller and a terminal, use an adapter cable and
a null modem cable.
Adapter Cable

Adapter Cable
Examples of Sun cables that can be used as adapter
cables are:
530-1178-01 (ALM-1, RS-232)
530-11 79-01 (ALM-1, RS-232)
530-1312-02 (ALM-2, Printer)
530-1313-01 (MCP, RS-232)
Sun SMD data cables cannot be used as the adapter
cable because they do not have pin 2.
Null Modem Cable
The null modem cable must have pins 2 and 3 crossed
and pin 7 straight. A Laserwriter cable, 530-1172-03, is
an example of this type of cable.

DISK-26

Field Engineer Handbook

TROUBLESHOOTING

TAPE

TROUBLESHOOTING

12/90

Tape
TAPE DRIVES
CDC 1/2" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Fujitsu 1/2" ...............................

3
5

CONTROLLERS
1/4" Tape
Emulex MT02 ...........................

8

1/2" Tape
Ciprico Tapemaster .......................
Xylogics 472 . . . . . . . . . . . . . . . . . . . . . . . . . . . ..

12
13

Field Engineer Handbook - Technical Volume II

12/90

TROUBLESHOOTING

This page intentionally left blank.

TAPE-2

Field Engineer Handbook

TROUBLESHOOTING

12/90

CDC 112" Tape Drive
Self-Test Procedure
SELF-TEST 01
1.
2.
3.
4.

Thread a write enabled tape onto the takeup reel.
Press the LOGIC ON button.
Press TEST button.
Press the EXECUTE button to start self test 1.
SELF-TEST 91

1.
2.
3.
4.
5.
6.
7.
8.

Thread a write enabled tape onto the takeup reel.
Press and hold the CE button.
Press TEST button.
Release the CE button.
Press the STEP button to increment the LED display to 09.
Press the TEST button to increment the LED display to 90.
Press the STEP button to increment the LED display to 91.
Press the EXECUTE button to start self test 1.
TEST 91 CONTINUOUS LOOP MODE

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.

Thread a write enabled tape onto the takeup reel.
Press and hold the CE button.
Press TEST button.
Release the CE button.
Press the STEP button to increment the LED display to 09.
Press the TEST button to increment the LED display to 90.
Press the STEP button to increment the LED display to 91.
Press and hold the CE button.
Press the EXECUTE button to increment the LED display to 00.
Release the CE button.
Press the STEP button to increment the LED display to 01.
Press the EXECUTE button to start self test 91 in a continuous
loop.

Reference
CDC Streaming Tape Unit 92181 Field Service Manual. There is no
Sun part number for this manual.

Technical Volume II

TAPE-3

TROUBLESHOOTING

12/90

CDC 1/2" Tape Drive
Off-Line Diagnostic Error Codes
FAULT
CODE

01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20

DESCRIPTION

Read envelope fault
Read amplitude tolerance fault
ID fault
Low speed write errors
Low speed read errors
High speed wirte errors
High speed read errors
Noise in IBG
Reserved for future use
Operator door open
Absence of tape
Load fault

FAULT
CODE

33
34
35
36
37
38
to

46
47
48
49
50

BOT location fault
Diag. tape is write protected
Ran off end of tape
Tape already loaded
Reserved for future use
File tension sensor fault

21

Take-up tension sensor fault

22
23
24
25
26
27
28
29
30
31
32

Unable to tension tape
Unable to re-establish tension
High tension fault
Low tension fault
Servo fault

Tape prositioning fault
BOT positioning fault
Positioning fault
Speed fault
Pump power-up
Not Used
Velocity correction fault
Unload fault
Not Used
Irrecoverable device health
check fault

51

Recoverable device health
check fault

52

Speed calculation fault

53
54
55
56
57
58

Arithmetic error

59

Irrecoverable formatter health
check fault

60

Irrecoverable operator health
panel

61

Recoverable operator health
panel fault

Tape threaded incorrectly
Load/unload aborted operator

DESCRIPTION

Erase/write current fault
Load/rewind timeout error
Processor communication fault
Device illogical fault
Recoverable formatter health
check fault

No coarse tachs
Tension recovery problem
Absence of tape
Up ramp fault
Down ramp fault
Stoplock over-run

TAPE-4

Field Engineer Handbook

TROUBLESHOOTING

12/90

Fujitsu 112" Tape Drive
Operator Panel Layout
Indicates paR self

r- test completion
Illuminates when
00 = Normal ON
write density is
L 1 = Door open
Illuminates when
set for PE
L2 = Reel latch open a write operation
L3 = Tape loose
is inhibited
L4 = BOT not found
Illuminates when
L5 = Tape not in
Se,lects th~ write density is
tape path
write density set for GCR"-LP = Tape at load
mode of unit
point
Write file
Illuminates when
protection
Other displays indicate
host can change
'- a fault symptom code
the write density

BoBo

1 _....1
LEOs _1-_ _..1.for head
azimuth
check

IT

I

/

When loading.
moves tape 64
revolutions. then
to BOT
Illuminated when unit
is ready and enabled
to the controller

Technical Volume II

o HOST_

0
FILE
PROTECT

0

DENSITY
SELECT

0
UNLOAD

TEST

\
I

Unloads tape
to supply reel
I Illuminated during
unload operation

06250 01600 -

r-

CJ\
:\

Illuminates during
diagnostic routines
and error codes

\

Resets unit
and resets
diagnostic
routines

TAPE-5

TROUBLESHOOTING

12/90

Fujitsu 1/2" Tape Drive
Self-Test Procedures
1.

Thread a write enabled tape onto the takeup reel.

2.

Press and hold TEST.

3.

Press START.

4.

Release TEST

5.

Press START to increment the LED display to 01.

6.

Press TEST to start self test 01 through 42.

Operator Panel Diagnostic Routines
CODE

FUNCTION

00
01
02
03
04
05
06
09

No operation
Load and run default test routine from code 10 to 42.
Load
Rewind
Unload
Retension
Run routine 10 - 19
Ignore door switch

10
11
12
13
14
15
16
17
18
19

Check reset test
LSI scan test
Time sensor test
Block format test
LWR test GCR high/low
LWR test PE high/low
Mask/error track test by
Mask/error track test by
Mask/error track test by
Mask/error track test by

LWR
LWR
LWR
LWR

GCR, high speed
GCR, low speed
PE, high speed
PE, low speed

Reference
Fujitsu M244X Streaming Tape Drive CE Manual, 800-1409-01.

TAPE-6

Field Engineer Handbook

TROUBLESHOOTING

12/90

Fujitsu 1/2" Tape Drive
Operator Panel Diagnostic Routines - Continued
FUNCTION

CODE

20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41

Tacho counter test (OCTRH, OCTRL)
Read level test by GCR high speed
Feed through test by PE low speed
GCR indentification burst test
PE indentification burst test low speed
PE indentification burst test high speed
GCR/low/normal/combination command test
GCR/low/long/combination command test
GCR/high/normal/combination command test
GCR/high/long/combination command test
PE/low/normal/combination comand test
PE/low/long/combination command test
PE/high/normal/combination command test
PE/high/long/combination command test
GCR error detection/correction test
PE error detection/correction test
Tape mark detection test
BOT test by GCR
BOT test by PE
Command sequence test by GCR
Command sequence test by PE
Data security erase test

42
90
91
92
93
94
95
96
97
99

Unload and offline
BOT/EaT sensor gain adjustment
Azimuth adjustment
PE read amplifier adjustment
EC level/device type set
Device parameter set
Reserved for tension test
Reserved for idler erase test
Buffer parameter settings
Run initial diagnostics and reset diagnostics mode

Technical Volume II

TAPE-?

12/90

TROUBLESHOOTING

MT02 Tape Controller
Sense Error Class/Code
TAPE DRIVE
HEX
ERROR
CODE
No Sense
00

04
09

OA

OB

The MT02 controller detected no error
during execution of the previous
command.
The tape drive is not powered up and
Drive Not Ready
ready.
Media Not Loaded The media cartridge is not installed in the
tape drive, as indicated by a tape drive
status signal.
Insufficient
There is insufficient space on the media
to allow additional data from the initiator
Capacity
to be accepted.
A timeout occurred during a tape drive
Drive Timeout
operation.

TARGET
HEX
ERROR
CODE
11
Uncorrectable
Data Error
14
Block Not Found
16

DMA Timeout
Error

17

Write Protected

18

Correctable Data
Check

TAPE-8

DESCRIPTION

DESCRIPTION
A block could not be written or read after
16 retry attempts.
The block sequence is improper or a
block is missing.
System activity reached a point at which
DMA service for the MT02 controller was
suspended beyond the allowable timing
limits, requiring one or more retry
attempts.
The media cartridge is write protectd.
The outstanding Write command has been
aborted.
During read operations, a block has to be
read two or more times. During write
operations, a block had to be written
more than once.

ReId Engineer Handbook

12/90

TROUBLESHOOTING

MT02 Tape Controller
Sense Error Class/Code - Continued
TARGET
HEX
ERROR
CODE
19
Bad Block
Found
1C
File Mark Detected
(Vendor Unique)

10

Compare Error

DESCRIPTION
A block cannot be read correctly after
16 retry attempts.
A file mark block was encountered
during a read operation. The outstanding
Read and Verify commands are
terminated and the tape is repositioned
just after the file mark block.
One or more bytes did not compare
when the Verify command was issued.

HEX SYSTEM RELATED
DESCRIPTION
CODE
ERROR
20
Invalid Command The issued command cannot be
implemented, or is not applicable.
30
Unit Attention
A Unit Attention condition occurred. The
removable media may have been
changed, or the addressed LUN has been
reset (by the Bus Device Reset message)
since the last command was issued to the
addressed LUN. This error is reported
the first time any command is issued
after the condition is detected and the
requested command is not performed.
This condition is cleared when the next
I/O is issued by the same host adapter.
31
Command
Command execution was not completed
by the MT02 before a predetermined,
Timeout
command-specific time limit expired.
Append Error
A write operation to the tape device was
33
attempted before the end-of-media was
reached.
34
Read
A read operation to the tape device was
End-of-Media
attempted past the end-of-media position.

Technical Volume II

TAPE-9

12/90

TROUBLESHOOTING

MT02 Tape Controller
Sense Key Errors
HEX
ERROR
CODE
No Sense
00

01

02
03

04
05

06

07

08

DESCRIPTION

There is no Sense Key information to
be reported for the designated LUN. This
code occurs for a successful command or
for a command that was checked because
the FM or EOM bit in the Extended Sense
(Byte 02) was set to 1.
Recoverable
The last command was completed
successfully with some recovery action
Error
performed.
The addressed LUN cannot be accessed.
Not Ready
Operator intervention may be required.
The command terminated with a nonMedia Error
recoverable error condition which was
probably caused by a flaw in the media or
by an error in the recorded data.
Hardware Error A non-recoverable hardware error was
detected.
Illegal Request An illegal parameter in the command or in
the additional parameters was supplied as
data for some commands.
Unit Attention
A Unit Attention condition occurred. This
error is reported the first time any command
is issued after the condition is detected and
the requested command is not performed.
This condition is cleared when the next 110
is issued by the same host adapter.
A write operation was attempted on a write
Data Protect
protected device either because the
cartridge is in the SAFE state.
Blank Check
The MT02 Controller encountered the
end-of-recorded media (lack of data).
This condition is not the same as the
physical EOM.

TAPE-10

Field Engineer Handbook

12/90

TROUBLESHOOTING

MT02 Tape Controller
Sense Key Errors - Controlled
HEX
ERROR
CODE
09
Vendor Unique

OA

Copy Aborted

OB

Aborted
Command

OC
OD

Reserved
Volume
Overflow

OE

Miscompare

OF

Reserved

Technical Volume II

DESCRIPTION
A Vendor-Unique error condition occurred.
The corresponding Error Class and Error
Code are specified in Byte 08 of the
Extended Sense Byte.
A Copy command was aborted because an
error condition was detected on the source
or destination device.
The Target aborted the command. The
Initiator may recover by trying the command
again.
A buffered device has reached the end-ofmedia and data which has not been written
to tape remains in the buffer. A Recover
Buffered Data command can be issued to
read the unwritten data from the buffer.
Used by the Verify command to indicate that
the source data did not match the data read
from the tape.

TAPE-11

TROUBLESHOOTING

12/90

Ciprico Tapemaster Controller

CODE

DESCRIPTION OF ERROR

00

No unrecoverable error

01
02

Timed out waiting for expected data busy false.

03

Timed out waiting for expected ready false.

Timed out waiting for expected data busy false formatter busy false
and ready true.

04

Timed out waiting for expected ready true.

05

Timed out waiting for expected data busy true.

06

A memory time-out occurred during a system memory reference.

07

A blank tape was encountered where data was expected.

08
09

An error occurred in the micro-diagnostic.
An unexpected EOT was encounted during a forward operation or
during a rewind operation.

OA

A hard or soft error occurred which could not be eliminated by retry.

08

A read overflow or write underflow occurred. This error indicates that
the FIFO was empty when data was requested by the tape during a
write or full when the tape presented a byte during a read.

OC

Not used

OD

A read parity error occurred on the byte interface between the drive
and controller.

OE

An error was detected while calculating a checksum on the PROM.

OF

A tape time-out occurred because the tape drive did not supply an
expected read or write strobe. This normally occurs when attempting
to read a larger record than was written.

10

Tape not ready

11
12
13

A write was attempted on a tape without a write-enable ring.

14
15
16

Not used
The diagnostic jumper was not installed while attempting to execute a
diag command.
An attempt was made to link from a command which does not allow
linking.
An unexpected file mark was encountered during a tape read.
An error in specifying a parameter was detected by the Tapemaster.
The usual cause is an entry in the byte count field which is zero or
too large.

17

Not used

18
19

An unidentifiable hardware error occured. Consult factory.
A streaming read or write operation was terminated by the operating
system or disk.

TAPE-12

Field Engineer Handbook

12/90

TROUBLESHOOTING

Xylogics 472 1/2" Tape Controller
CODE

DESCRIPTION OF ERRORITROUBLESHOOTING TIPS

00

Not an error

01

Interrupt pending. An operation is attempted while an
interrupt is pending.

03

Busy conflict. A register write is attempted while the
controller is busy.

04

Operation timeout. The controller did not complete the
operation within the timeout period (usually a few seconds).
Check the jumpering on the controller, make sure the board
is seated properly in an appropriate slot, and check the
switch settings of the VME-MB adapter, if applicable.
Check the backplane configuration, (VME only).

06

Uncorrectable data. Data error reported on a read
command (after four retries of the operation).

OE

Slave acknowledge error (non-existent memory). The
memory addressed by the controller fails to respond within
the slave acknowledge timeout period. Validate the memory
address or memory itself and retry.

14

Write protect error. A write operation is attempted on a
write-protected tape reel.

15

Unimplemented Command. Usually reported by the
software. Check the device driver.

16

Drive Off-line. The controller cannot perform the requested
operation if the drive is not on-line. If the tape is properly
loaded and the drive on-line indicator is On, check the
cables.

1A-1C Self test failure - A, B, C. Contwller failed the self test
diagnostic. Check indicator LED on board (Diag Busy).
On POR the self test LED is On briefly and then goes Off.
If the LED stays on, self test A, B, or C has failed. Replace
the controller.

Technical Volume II

TAPE-13

12/90

TROUBLESHOOTING

Xylogics 472 1/2" Tape Controller
Continued
DESCRIPTION OF ERRORITROUBLESHOOTING TIPS

CODE

10

Tape mark failure. A tape mark is not detected during a
write tape mark operation. Check the setup of the tape
drive and the condition of the tape. Run the tape drive
self-diagnostic to check the drive's ability to sense tape
marks.

1E

Tape mark detected. A tape mark is detected on a Read
operation. No data is transferred. Check the data cable
from the controller to the drive. Check for proper seating
on the read formatter board, the buffer card, and the
processor card. Check the proper positioning of the
read amplifier. Verify tape operation with self-diagnostic.

1F

Corrected data. Tape drive error correction corrected a
single track error during a Read operation.

22

Record length short. Record length is shorter than expected.
Result is part of the buffer is not used. Run Read/Write
tests on the drive with the known good tape.

23

Record length long. The requested file is longer than expected
Only requested byte count is transferred. This may appear
to be a recovered operation, however, the rest of the data
is not transferred.

30

Reverse into BOT. A beginning of tape mark is detected
while tape is moving in the reverse direction. The tape
motion stops. Check tape, run self-diagnostics.

31

EOT detected. An end of tape mark is passed in the
forward direction. Check tape, run self-diagnostics.

32

ID burst detected. A PE or GCR identification burst is
detected while reading or writing from BOT. In the host
mode, software can change before start of an operation.
This change can also be set at the drive during load time.
Check drive parameters for operation.

33

Data late detected. Indicates system bus contention. The
FIFO underflowed during a write operation, or the FIFO
overflowed during a read operation. Check the data path
and configuration, especially when there are other bus
masters.

TAPE-14

Field Engineer Handbook

TROUBLESHOOTING

COMMUNICATION

TROUBLESHOOTING

12/90

Communication
CPU Serial Ports ..........................
Sun-4/20 CPU Serial Ports . . . . . . . . . . . . . . . . . ..
Sun386i Serial and Parallel Ports ..............
Sun-4/40 CPU Serial Ports . . . . . . . . . . . . . . . . . ..
CPU Keyboard and Mouse .................. ,
Sun386i Color Frame Buffer . . . . . . . . . . . . . . . . ..
Sun386i Monochrome Frame Buffer ...........
CPU Audio Port ...........................
Sun-4/E Serial Ports . . . . . . . . . . . . . . . . . . . . . . ..
Ethernet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
ALM-1 ...................................
ALM-2 ................. .............. ....
MCP .....................................
SCP .....................................
VME HSI..................................
SBus HSI ........................... . . . . ..
SBus Printer . . . . . . . . . . . . . . . . . . . . . . . . . . .... ,
SBus Serial Parallel Controller ................
SCSI Connector Pinouts ... . . . . . . . . . . . . . . . . ..
RS-232 Signals . . . . . . . . . . . . . . . . . . . . . . . . . . ..
RS-449 Signals ........................... ,
RS-530 Signals . . . . . . . . . . . . . . . . . . . . . . . . . . ..
Electrical Characteristics . . . . . . . . . . . . . . . . . . . ..

FOOl .....................................
SPARCprinter . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..

Field Engineer Handbook - Technical Volume II

3
3
4
4
5
5
5
6
6
6
7
7
8
8
9
10
11
12
13
14
15
16
17
20
23

12/90

TROUBLESHOOTING

This page intentionally left blank.

COMM-2

Field Engineer Handbook

12/90

TROUBLESHOOTING

CPU RS-232/RS-423
(9-Pin D-Sub, Female)
PIN

SIGNAL

1
2
3
4
9

DCD
RD
TD
DTR
Unused

PIN
5

6
7

8

Board Connector

SIGNAL
GND
DSR
RTS
CTS

5~1
9 0000
6

CPU RS-232/RS-423
(25-Pin D-Sub, Female)
PIN
2
3
4
5

6
7

SIGNAL
TD
RD
RTS
CTS
DSR
GND

Board Connector

PIN

SIGNAL

8

DCD
TC
RC
DTR
TCO
-5 vdc

15
17
20
24
25

130000000000000 1
25 0 0 0 0 0 0 0 0 0 0 0 0
14

Sun-4/20 CPU RS-232/RS-423 Ports A & B
(25-Pin D~Sub, Female)
(Port B is asynchronous only)
PIN
2
3
4
5

6
7

8
12
13

SIGNAL PORT
TD
RD
RTS
CTS
DSR
GND
DCD
DCD
CTS

A
A
A
A
A
A
A

8

PIN
14
15

16
17
19
20
24
25

SIGNAL
TD
TC
RD
RC
RTS
DTR
TCO

Board Connector
130000000000000 1
25 000000 0 00000
14

PORT
B
A
B
A
B
A
A

B

Technical Volume II

COMM-3

TROUBLESHOOTING

12/90

Sun386i CPU RS-232/RS-423 Port A
(25-Pin D-Sub, Male)
PIN

SIGNAL

PIN

SIGNAL

TD
RD
RTS
CTS
DSR
GND
DCD

15
17
20
22
24
25

TC
RC
DTR
RI
TCO
-5 vdc

2
3
4
5
6
7
8

Board Connector
13
25

0000000000000 1
000000000000
14

Sun386i CPU Parallel Port
(25-Pin D-Sub , Female)
PIN
1
2
3
4
5
6
7
8
9
10
11
12
13

SIGNAL
STRB
Data Bit 0
Data Bit 1
Data Bit 2
Data Bit 3
Data Bit 4
Data Bit 5
Data Bit 6
Data Bit 7
ACK
BUSY
PE
SLCT

PIN
14
15
16
17
18
19
20
21
22
23
24
25

SIGNAL
AUTOFXDT
ERROR
INIT
SLCTIN
GND
GND
GND
GND
GND
GND
GND
GND

Board Connector
13
25

0000000000000 1
00000 0 000000
14

Sun-4/40 CPU RS-232/RS-423 Ports A & B
(8-Pin Mini-Din) (asynchronous only)
PIN
1
2
3
4

COMM-4

SIGNAb
DTR
RD
TD
SG

PIN
5

6
7
8

Board Connector

SIGNAL
RD
RTS
DCD
RC

Field Engineer Handbook

12/90

TROUBLESHOOTING

CPU Keyboard and Mouse
(8-Pin Mini-Din)
PIN
1
2
3
4

SIGNAL

PIN

GND
GND
VCC
RD (Mouse)

Board Connector

SIGNAL
TD
RD
TD
VCC

5
6
7
8

(Keyboard)
(Keyboard)
(Mouse) *

* Can be configured as transmit on the 4300, 4400 and 3/80 CPUs,

CPU Keyboard and Mouse
(15-Pin D-Sub, Female)
PIN
1
2
3
4
5
6
7

SIGNAL
RD (Keyboard)
GND
TD (Keyboard)
GND
RD (Mouse)
GND
TD (Mouse)

PIN

SIGNAL

8

GND
GND
VCC
VCC
VCC
VCC
VCC

9
10
11
12
14
15

Board Connector
8
15

~ 0 0 00 0 00) 1
0 0 0 0 00 0

9

Sun386i Color FB Video/Keyboard/Mouse
(DB21W4)
PIN
1
3
8
10
12

SIGNAL
TD (Mouse)
RD (Keyboard
TDB
GND
GND

PIN

SIGNAL

14
A1
A2
A3

GND
Red
Green
Blue
C sync

A4

Board Connector

17

10

Sun386i Black and White FB Video/Keyboard/Mouse
(DB 15-Pin, D-Sub, Male)
PIN
1
2
3
4
5
6
7
8

SIGNAL

PIN

TD (Mouse)
RD (KyBd)
TD (KyBd)
Vcc (KyBd)
V sync
H sync
V out
TDB

10
11
12
13
14
15

Technical Volume II

9

SIGNAL
GND
GND
GND
Vcc (KyBd)
GND
GND
V out

Board Connector
8 <\0 0 0 0 0 0 00) 1
15
0 0 0 0 0 00
9

COMM-5

12/90

TROUBLESHOOTING
CPU Audio Port
(a-Pin Mini Din)
PIN
1
2
3
4

Board Connector

SIGNAL

PIN

L In-1 (ISDN)
L In-2 (ISDN)
Microphone Tip
L Out-1 (ISDN)

5

6

T
a

SIGNAL
L Out-2 (ISDN)
Microphone Ring
Speaker Ring
Speaker Tip

Sun 4/E CPU RS-423/RS-232C Port A
Asynchronous only
(15-Pin D-Sub, Female)
PIN
1
2
3
4
5

6
7
a

SIGNAL
GND
TO
RDRTS
CTSDSR
DTR
DCD

PIN

9
10
11
12
13
14
15

SIGNAL
RTS+
RTSCTS+
TD+
TDRD+
GND

Board Connector
6
'--_ _~ 11

Sun 4/E CPU RS-422/RS-RS-423/RS232C Port B
Asynchronous or Synchronous
(15-Pin D-Sub, Female)
PIN
1
2
3
4
5

6
7
a

SIGNAL
GND
TO
RDRTS
CTS
DSR
DTR
DCD

PIN

9
10
11
12
13
14
15

SIGNAL
TC
TCO
RC
TD+
TDRD+
GND

Board Connector

' - - _ _J

6
11

Ethernet
(15-Pin D-Sub, Female)
PIN
2
3
5

6
7

SIGNAL
E.COL+
E.TD+
E.RD+
GND
+5vdc'

PIN

9
10
12
13

SIGNAL
E.COLE.TDE.RD+12vdc

Board Connector
8 \:00 0 00 0 00] 1
15
0 0 0 0 0 0 0
9

'Not used, jumper selectable on some boards

COMM-6

Field Engineer Handbook

12/90

TROUBLESHOOTING

ALM-1 RS-232 Ports 0-15
(25-Pin D-Sub, Female)
PIN
1
2
3
4
5

6

SIGNAL

PIN

SIGNAL

FG

7
8
15
17
20

GND
DCD
TC
RC
DTR

TO
RD
RTS
CTS
DSR

Board Connector
1300000000000001
25 000 0 0 0 0 0 000 0
14

ALM-2 RS-232 Port 4-15 (25-Pin D-Sub, Female)
PIN
2
3
7

SIGNAL

PIN

SIGNAL

TO

8
20

DCD
DTR

RD
GND

DCA Connector
13
25

0000000000000 1
000 0 0 0 0 0000 0
14

ALM-2 RS-232/RS-423 Ports 0-3 and
MCP RS-232/RS-423 Ports 2 and 3
(25-Pin D-Sub, Female)
PIN
2
3
4
5

6
7

SIGNAL

PIN

SIGNAL

TO

8
15
17
20
24

DCD
TC
RC
DTR
TC

RD
RTS
CTS
DSR
GND

DCA Connector
1300000000000001
25 0000000 00000
14

ALM-2 Parallel Port (25-Pin 0- Sub, Female)
PIN
1
2
3
4
5
6
7
8
9
10

SIGNAL
STRB
Data Bit 0
Data Bit 1
Data Bit 2
Data Bit 3
Data Bit 4
Data Bit 5
Data Bit 6
Data Bit 7
ACK

PIN
12
13
18
19
20
21
22
23
24

Technical Volume II

SIGNAL
PE
SLCT
GND
GND
GND
GND
GND
GND
GND

DCA Connector
13
25

0000000000000 1
000 0 0 0 0 0 000 0
14

COMM-7

TROUBLESHOOTING

MCP RS-449 Port a & 1
(37-Pin D-Sub, Female)
PIN
SIGNAL
PIN
4
22
SD23
5
ST24
6
RD7
25
RSRT26
8
27
9
CS29
11
DM12
TR30
13
31
RR17
35
TTSG
19
SCP RS-449 Ports a & 2
(37-Pin D-Sub, Female)
PIN
SIGNAL
PIN
1
Shield
20
4
21
SD22
5
ST23
6
RD7
24
RS25
8
RT26
9
CS11
27
DM12
29
TR13
RR30
17
35
TT19
SG
SCP RS-232 Ports 1 & 3
(25-Pin D-Sub, Male)
PIN
SIGNAL
PIN
1
FG
8
TD
15
2
RD
17
3
4
RTS
29
CTS
24
5
6
DSR
25
7
SG

COMM-8

12/90

SIGNAL
SD+
ST+
RD+
RS+
RT+
CS+
DM+
TR+
RR+
TT+

SIGNAL
RC
TT+
SD+
ST+
RD+
RS+
RT+
CS+
DM+
TR+
TT+

SIGNAL
DCD
TD
RD
DTR
TC
+5vdc

Board Connector
190000000000000
37 0 00 0 0 0 0 0 0 0 0 0

1
20

Board Connector
19
37

0000000000000
000 0 0 0 0 0 000 0

1
20

Board Connector
130000000000000 1
25 0 0 0 0 0 0 0 0 0 0 0 0
14

Field Engineer Handbook

12/90

TROUBLESHOOTING

VMEbus HSI RS-449/RS-422 Port A & B
(37-Pin D-Sub, Female)
PIN

SIGNAL

PIN

SIGNAL

4
5
6
7
8
9
11
12
13
17
19

SDSTRDRSRTCSDMTRRRTISG

22
23
24
25
26
27
29
30
31
35
37

SD+
ST+
RD+
RS+
RT+
CS+
DM+
TR+
RR+
TI+
SG

Board Connector
19
37

0000000000000
1
000 0 0 0 0 0000 0
20

VMEbus HSI V.35 Port A & B
(25-Pin D-Sub, Female)
PIN

SIGNAL

PIN

2
3
4
5
6
7
9
10
11

SG
TD+
RD+
TI+
TC+
RC+
RTS
DCD
DSR

11
15
16
17
18
19
20
21

Technical Volume II

SIGNAL
DSR
TDRDTTTCRCCTS
DTR

Board Connector
13
25

0000000000000 1
00000 0 0 00000
14

COMM-9

12/90

TROUBLESHOOTING
SBus HSI RS-530 Port 0, 1, 2, & 3
(25-Pin D-Sub, Female)
PIN
2
3
4
5
6
7
8
9
10
11
12

SIGNAL
BM (TD)
BB+ (RD)
CM (RTS)
CB+ (CTS)
CC+
SG
CF+
DDCFDADB- (TC)

PIN
13
14
15
16
17
19
20
22
23
24

SIGNAL
CB- (CTS)
BA- (TD)
DB+ (TC)
BB- (RD)
DD+
CA- (RTS)
CD+
CCCDDA+

Patch Panel Connector
13
25

0000000000000
1
000000000000
14

Note: RS-530 and RS-232 signal levels are not compatible. Install an
RS-232 to RS-530 or an RS-422 to RS-530 Converter on each
port.

COMM...,10

Field Engineer Handbook

12/90

TROUBLESHOOTING

SBus Printer Board Video Port
(20-Pin D-Sub, Female)
PIN
1
2
3
4
5
6
7
8
9
10

SIGNAL
VCLK+
LSYNC+
STATUS+
PSYNC+
Do not use
Do not use
Do not use
CBUSYCMD+
GND

PIN
11
12
13
14
15
16
17
18
19
20

SIGNAL
VCLKLSYNCSTATUSPSYNCDo not use
Do not use
Do not use
CBUSY+
CMDVDATA-

Board Connector
10
20

0000000000000 1
0000 0 0 0 0000 0
11

SBus Printer Board Parallel Port
(28-Pin D-Sub, Female)
PIN
1
2
3
4
5
6
7
8
9
10
11
12
13
14

SIGNAL
Data Bit 0
Data Bit 1
Data Bit 2
Data Bit 3
Data Bit 4
Data Bit 5
Data Bit 6
Data Bit 7
GND
DSBUSY
RESETAFXTSELECT

Technical Volume II

PIN
15
16
17
18
19
20
21
22
23
24
25
26
27
28

SIGNAL
Do not use
Do not use
Do not use
Do not use
Do not use
GND
GND
do not use
GND
GND
ACKOUT/INPE
ERROR-

Board Connector
14
28

0000000000000 1
000000 000000
15

COMM-11

TROUBLESHOOTING

12/90

Serial Parallel Controller AS-232/AS-423
(25-Pin D-Sub, Female)
PIN

SIGNAL

PIN

SIGNAL

1
2
3
4
5

F GND
TD
AD
ATS
CTS

6
7
8
20

DSA
SG
DCD
DTA

DCA Connector
1300000000000001
25 000000000000
14

Serial Parallel Controller Parallel Port
(25-Pin D-Sub, Female)
PIN
1
2
3
4
5
6
7
8

9
10
11
12
13

SIGNAL
STAB
PDO
PD1
PD2
PD3
PD4
PD5
PD6
PD7
ACK
BUSY
PAPE
SLCT

COMM-12

PIN
14
15
16
17
18
19
20
21
22
23
24
25

SIGNAL
AFXN
EAAN
ININ
SLCN
GND
GND
GND
GND
GND
GND
GND
GND

DCA Connector
13
25

0000000000000 1
0 00 0 0 0 0 0 0 0 0 0
14

Field Engineer Handbook

12/90

TROUBLESHOOTING

SCSI Connector Pinouts
SCSI
SIGNAL
-09(0)
-09(1 )
-09(2)
-09(3)
-09(4)
-09(5)
-09(6)
-09(7)
-D9(P)
GNO
GNO
GNO
TERMPWR
GNO
GNO
-ATN
GND
9SY
-ACK
-RST
-MSG
-SEL
-C/O
-REO
-I/O
• NC

= Not

MINI
DD-50P MICRO DD-50SA
2
26
34
4
27
2
6
28
19
8
29
36
10
4
30
12
31
21
14
32
38
16
33
6
18
34
23
20
GNO
40
22
GNO
8
NC*
24
25
26
38
42
NC*
28
10
30
GNO
27
32
41
44
34
GND
12
36
43
29
44
38
46
40
45
14
42
31
46
44
47
48
46
48
16
48
49
33
50
50
50

SCSI
MINI
SIGNAL DD-50P MICRO DD-50SA
GND
1
1
1
GNO
2
18
3
GND
5
3
35
GNO
7
4
3
9
5
GND
20
GND
11
6
37
GNO
7
5
13
GND
15
22
8
GND
17
9
39
GND
19
10
7
24
GND
21
11
GND
41
23
NC
GND
NC
25
9
GND
27
NC
26
GND
29
15
43
GND
31
16
11
GND
17
28
33
GNO
18
45
35
GND
37
19
13
GND
39
20
30
GND
41
21
47
43
GND
22
15
GND
45
23
32
GND
47
24
49
GND
49
25
17

connected

Connector Types
MINI-MICRO

DD-50P

DD-50SA

or

HIGH-DENSITY
49 0 0 0 0 0 0 0 0 0 0 0 0

1

50

2

000000000000

25 0 00 0 0 0 0 0 0
5000000000

1

26

17 0 0 0 0 0 0 0 0 0 0
33
50

50-Pin, Male

Technical Volume II

50-Pin, Female

1
000000000
18
0 0 0 0 0 0 0 0 0 0 34

50-Pin, Female

COMM-13

12/90

TROUBLESHOOTING

RS-232 Signals
PIN

2
14

SIGNAL
SIGNAL NAME
BA
Transmit Data
or

DIRECTION
DESCRIPTION
Output
Data transmitted to the data
communications equipment.

TO

3
16

BB
or
RD

Receive Data

Input

Data received from the data
communications equipment.

4
19

CA
or
RTS

Request to Send

Output

Signal sent to the data communications equipment, asking if it is
ready to start accepting data.

5
13

CB
or
CTS

Clear to Send

Input

Ready to accept data signal
from the data communications
equipment.

6

CC
or
DSR

Data Set Ready

Input

Data communications equipment
indicates the status of the local
data set.

7

AB
or
SG

Signal Ground

None

Signal Ground provides a
reference level for the signal
voltages.

8
12

CF
or
DCD

Data Carrier Detect

Input

Data communications equipment
detected "carrier." Example: a
modem senses tones sent to it
by another modem over phone
lines.

15

DB
or
TC

Transmit Clock
from DCE

Input

Transmit clock from the modem.
Usually not used for asynchronous devices (terminals, printers,
and modems, etc).

17

DO
or
RC

Receive Clock
from DCE

Input

Receive clock from the modem.
Usually not used for asynchronous devices (terminals, printers,
and modems, etc).

20

CD
or
DTR

Data Terminal
Ready

Output

The DTE is powered on and
ready to communicate as the
"local data terminal" with the
data communication equipment.
For example, the modem.

24

DA
or
TCO

Transmit Clock
from DTE

Output

Provides transmit clock from the
DTE. Usually not used for
asynchronous devices, (terminals,
printers, and modems, etc).

COMM-14

Field Engineer Handbook

12/90

TROUBLESHOOTING

RS-449 Signals
PIN

4
22

SIGNAL
SIGNAL NAME
SD
Transmit Data
or

DIRECTION
DESCRIPTION
Output
Data transmitted to the data
communications equipment.

TO

RD

Receive Data

Input

Data received from the data
communications equipment.

7
25

RS
or
RTS

Request to Send

Output

Signal sent to the data communications equipment. asking if it is
ready to start accepting data.

9
27

CS
or
CTS

Clear to Send

Input

Ready to accept data Signal
from the data communications
equipment.

11
29

DM
or
DSR

Data Set Ready

Input

Data communications equipment
indicates the status of the local
data set.

19

SG

Signal Ground

None

Signal Ground provides a
reference level for the signal
voltages.

13
31

RR
or
DCD

Data Carrier Detect

Input

Data communications equipment
detected "carrier." Example: a
modem senses tones sent to it
by another modem over phone
lines.

5
23

ST
or
TC

Transmit Clock
from DCE

Input

Transmit clock from the modem.
Usually not used for asynchronous devices (terminals. printers.
and modems. etc).

8
26

RT
or
RC

Receive Clock
from DCE

Input

Receive clock from the modem.
Usually not used for asynchronous devices (terminals. printers.
and modems. etc).

12
30

TR
or
DTR

Data Terminal
Ready

Output

The DTE is powered on and
ready to communicate as the
"local data terminal" with the
data communication equipment.
For example. the modem.

17

IT
or
TCO

Transmit Clock
from DTE

Output

35

Provides transmit clock from the
DTE. Usually not used for
asynchronous devices. (terminals.
printers. and modems. etc).

6

24

Technical Volume II

COMM-15

TROUBLESHOOTING

12/90

RS-530 Signals
PIN

2
14

SIGNAL
SIGNAL NAME
SA
Transmit Data
or

DIRECTION
DESCRIPTION
Output
Data transmitted to the data
communications equipment.

TO

3
16

SS
or
RD

Receive Data

Input

Data received from the data
communications equipment.

4
19

CA
or
RTS

Request to Send

Output

Signal sent to the data communications equipment, asking if it is
ready to start accepting data.

5
13

CB
or
CTS

Clear to Send

Input

Ready to accept data signal
from the data communications
equipment.

6
22

CC
or
DSR

Data Set Ready

Input

Data communications equipment
indicates the status of the local
data set.

7

AS
or
SG

Signal Ground

None

Signal Ground provides a
reference level for the signal
voltages.

8
10

CF
or
DCD

Data Carrier Detect

Input

Data communications equipment
detected "carrier." Example: a
modem senses tones sent to it
by another modem over phone
lines.

12
15

DB
or
TC

Transmit Clock
(from DCE)

Input

Transmit clock from the modem.
Usually not used for asynchronous devices (terminals, printers,
and modems, etc).

9
17

DO
or
RC

Receive Clock
(from DCE)

Input

Receive clock from the modem.
Usually not used for asynchronous devices (terminals, printers,
and modems, etc).

20
23

CD
or
DTR

Data Terminal
Ready

Output

The DTE is powered on and
ready to communicate as the
"local data terminal" with the
data communication equipment.
For example, the modem.

11
24

OA
or
TCO

Transmit Clock
(from OTE)

Output

Provides transmit clock from the
DTE. Usually not used for
asynchronous devices, (terminals,
printers, and modems, etc).

COMM-16

Field Engineer Handbook

TROUBLESHOOTING

12/90

Electrical Characteristics
The U.S. Electronic Industries Association electrical specifications are included in this section with a reference to the
section in the standard for each circuit type. EIA standards
are available from the EIA Engineering Department, Standard
Sales, 2001 Eye Street. N.W., Washington, D.C. 20006.

EIA RS-232-C Section 2.3
For data interchange circuits, the signal shall be considered
in the marking condition when the voltage (V 1) on the interchange circuit, measured at the interface point, is more negative than minus three volts with respect to Circuit AB (Signal
Ground). The signal shall be considered in the spacing condition when the voltage (V 1) is more positive than plus three
volts with respect to circuit AB. The signal state in not uniquely defined when the voltage (V 1) is in this transition region.
EIA RS-422-A Section 4.1.1
For either binary state, the magnitude of the differential voltage (Va) measured between the two generator output terminals shall not be less than 6.0 volts; nor shall the magnitude
of Vaa and Vab measured between the two generator output
terminals and generator circuit ground be more than 6.0 volts,
EIA RS-423-A Section 4.1.1
For either binary state, the magnitude of the voltage (Va)
measured between the generator output terminal and
generator circuit ground shall not be less than 4.0 volts nor
more than 6.0 volts. For the opposite binary state, the polarity
of Va shall be reversed.

Technical Volume II

COMM-17

TROUBLESHOOTING

12/90

Electrical Characteristics - Continued
EIA RS-449-A Section 2.1.1
The following circuits are classified as Category I circuits: SO,
RD, TT, ST, RT, RS, CS, RR, TR, and OM.
For applications where the signaling rate on the data interchange circuits (Circuits SO and RD) is 20,000 bits per
second or less, the individual Category I circuits shall use
either the balanced electrical characteristics of RS-423,
without the cable termination resistance (R t) , or the unbalanced electrical characteristics of RS-422-A. Two leads shall
be brought out to the interface connector for each Category I
circuit. Each interchange circuit consists of a pair of wires
interconnecting a balanced or unbalanced generator and a
differential receiver.
For applications where the signaling rate on the data interchange circuits (Circuits SO and RD) is above 20,000 bits per
second, all Category I circuits shall use the balanced electrical
characteristics of RS-422. Use of optional cable termination
resistance (R t ) is permitted. Each interchange circuit consists
of a pair of wires interconnecting a balanced generator and a
differential receiver.

EIA RS-449-A Section 2.1.2
All other circuits are classified as Category II circuits. For all
applications, Category II circuits shall use the unbalanced
electrical characteristics of RS-423. Each Category II interchange circuit consists of one wire interconnecting an unbalanced generator and a differential receiver.

COMM-18

Field Engineer Handbook

12/90

TROUBLESHOOTING

Electrical Characteristics - Continued
EIA RS-530 Section 2.1.1
The following circuits are classified as Category I circuits: BA,
BB, DA, DB, CA, CB, CF, CC, and CD.
The individual Category I circuits shall use the balanced electrical characteristics of EIA-422-A. Two leads shall be
brought out to the interface connector for each Category I
circuit. Each interchange circuit consists of a pair of wires
interconnecting a balanced generator and a differential
receiver.
EIA RS-530 Section 2.1.2
The following circuits are classified as Category II circuits: RL,
LL, and TL.
The Category II circuits shall use the unbalanced electrical
characteristics of EIA-423-A. Each Category II interchange
circuit consists of one wire interconnecting an unbalanced
generator and a differential receiver.
EIA RS-530 Section 6.6
The connector used in this recommendation, is also used for
EIA-232-D, which employs electrical characteristics that, if
improperly connected to some silicon devices designed to
meet EIA-422-A and EIA-423-A electrical characteristics
specified in this recommendation, could damage those
devices.

Technical Volume II

COMM-19

TROUBLESHOOTING

12/90

FOOl
Selftest
Normal mode selftests run at powerup when the OIAG/NORM
switch is in the NORM position. Attach a terminal set for
9600 baud, 8 data bits, no parity, and 1 stop bit to the serial
port to monitor normal mode selftest output.
Extended Selftests
Extended selftests are run with the OIAG/NORM switch in the
OIAG position. Attach a terminal set for 9600 baud, 8 data
bits, no parity, and 1 stop bit to the serial port and attach
loopback cables between ports FOOI-A and FOOl-B. Enter s
to enable the extended selftests. Enter a to display the Oiagnostic Engineering Monitor (OEMON) menu.
LEOs
LEOs indicate the status of the FOOl PCB and the network
during operation.
LED
4

Off
path
On

Off
Off
On

LEOs
2 &0
Off
On
Off

On

Off

x

On

On

x
x

LEOs

3 &1

LED Status
Connection is dead
Connection sequence in progress
Connection is complete and is part of token
Connection is complete but there is no
token
Connection is too noisy

LEOs 4, 1, and 0 indicate connection status for port FOOl-A.
LEOs 4, 3, and 2 indicate connection status for port FOOl-B.
LEO 4, RINGOP, is ON when the ring is not operational.
LEO 5, PACKETIO, changes state each time a packet is received or successfully transmitted. LEOs 6 and 7 blink
alternately four times per second under normal conditions.
LEOs 6 and 7 blink together two times per second when a
non-recoverable firmware problem occurs.

COMM-20

Field Engineer Handbook

12/90

TROUBLESHOOTING

FOOl
LED Patterns During Powerup Selftests
• = ON

0= OFF

a

LEDs

7

• • • • • • ••
•••

Selftest Being Performed
A reset momentarily sets the LEDs to this state

0

0

0 0 0

System Enable Register Test

0

0

0 O . 0 00

NP Bus Error Test (Verify can detect a bus error.)

o

0

0 0

0

0

0 0

0

0

0

0

0

•
•

0

o.

Xmit Character/Serial Port Test

0 .0

EPROMO Checksum Test

00.

o ••

EPROM1 Checksum Test

o •

.00

IDPROM Checksum Test

o •

.0.

EEPROM Checksum Test

0

0

0

o

0

00. •• 0

0

0

0

0

0

0 .0 0

00

DMAC Xfer Count Register Test

0

0

0 .0 0

o.

DMAC Controller Register Test

o •

•••

VME Configuration Register Test
VME Interrupt Register Test

0

0

0.00

.0

DMAC Low Address Register Test

0

0

0

0

0

• 0
0 .0

••

DMAC High Address Register Test

o
o
o

•

00

0

0

0

• 0
0 .0

0

0

0

0

0

0

o

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

o

0

0

0

o
o

0

•

•
•
•

0

•

• O.
•
• • ••

.0

0

••
• • O.
•• o
•• ••
••
••
••
• • • ••

STC AM9513 LQM Register Test
FDDI Controller Register Test
RBC (RAM Buffer Ctlr) Basic Test

0

DPC (write. read) Basic Test
FORMAC Basic Test

0

ETXA (ENDEC) Basic Test

.00

ETXB (ENDEC) Basic Test

•
•

O.

.0

ACE Bits REG Access Test
GRP ADDR. Pntr. Reg. Test
GAR (Group Address RAM) Test

0 00

Buffer RAM Address Test

0

Buffer RAM ERRATIC Pattern Test

O.

0

0 .0

0

0

0
0
00

STC AM9513 Register Test

0 00

.0

0
0
0 0

MFP 68901 Registers Test

•

Buffer RAM ODD PARITY Test

••

MFP68901 Timer Test

00

STC9513 Timer Test

Technical Volume II

COMM-21

TROUBLESHOOTING

12/90

FDDI
LED Patterns During Powerup Sefltests - Continued
• = ON
7

a =OFF
LEOs

0

o 0 • 0 0 •

O.

Selftest Being Performed
LQM-STC9513 Timer Test

o 0 •

0

0

•• 0

LQM-A-STC9513 Line/Func/lnterrupt Test

o

0

0

•

••

LQM-B-STC9513 Line/Func/lnterrupt Test

o 0 • 0 •

0

0 0

RBC/SRAM Access Test

o 0 •

•

0

O.

RBC NMI (Non-Maskable-Interrupt) Test

o 0 • 0 •

0

•

FOR MAC MINTR (Maskable Interrupt) Test

o 0 •

0

•

0

••

o

0

•• 0 0

0

0

•

•

0

0

DPC NMI Test
Buff-RAM Parity Error Detect Test

o.

FOR MAC Internal Loopback Test

o 0 • 0 ••• 0

Endec A Internal Loopback Test

o 0 •

••

Endec B Internal Loopback Test

a

o 0 • 0 ••

0

•

•

o 0 •• 0 0

0

Fiber Loopback (WRP_A)

o 0 • • 0 0 O.

Fiber Loopback (WRP_B)

o 0 •• 0 0 • 0

Fiber Loopback (THR_A)

a ••

Fiber Loopback (THR_B)

o 0 •• 0

o 0 •• 0 •

0 0

Line States Fibr Loopback (THR_A)

o 0 •• 0 •

O.

Line States Fibr Loopback (THR_B)

o 0 •• 0 •• 0

Group Addr. Func. (WRP_A)

o 0 •• 0 •

••

Group Addr. Func. (WRP_B)

o 0 ••• 0 0 0

Group Addr. Func. (THR_A)

o 0 ••• 0

o.

Group Addr. Func. (THR_B)

o 0 ••• 0 • 0

Endec Parity Err .. Fibr LPBK (WRP_A)

o 0 ••• 0 ••

Endec Parity Err .. Fibr LPBK (WRP_B)

o 0 •••• 0 0

Endec Parity Err .. Fibr LPBK (THR_A)

o 0 • • • • O.

Endec Parity Err .. Fibr LPBK (THR_B)

o 0 •

•

•

•

•

0

CLAIM/BEACON Fibr LPBCK (WRP_A)

o 0 •

•

•

•

••

CLAIM/BEACON Fibr LPBCK (WRP_B)

o • 0 0 0 0 0 0

CLAIM/BEACON Fibr LPBCK (THR_A)

o •

0

0

0

0

O.

CLAIM/BEACON Fibr LPBCK (THR_B)

o •

0

0

0

0

•

LQM-A Circuit Function Test

0

o • 0 0 0 0 ••

COMM-22

LQM-B Circuit Function Test

Field Engineer Handbook

12/90

TROUBLESHOOTING

SPARCprinter
Operator Panel Diagnostic Routines
Operator Panel

D

GREEN - POWER ON

D

YELLOW - TONER LOW

D

LEDs YELLOW - DRUMLOW

~I
D

TEST

GREEN - PAPER OUT
GREEN - PAPER JAM

lalal
D

ENTER

lOT Test Print Mode
1. Switch the printer OFF.
2. Press and hold TEST.
3. Switch the printer ON.
4. Release TEST. 00 is displayed. The printer must warm-up for
approximately one minute in order to print a test page.
5. Press ENTER to start printing the lOT test print. The display indicates
the number of test pages printed.
6. Press ENTER to stop printing the lOT test print.
7. Switch the printer OFF to exit the lOT Test Print Mode.

Reference:SPARCprinter Service Guide, 800-5044.

Technical Volume II

COMM-23

OPERATING SYSTEMS

12/90

Operating Systems
The System Hardware and Operating System Dependency
tables in this section are compiled by Software Information
Services to illustrate support of hardware and software products by the Sun Operating System (SunOS) level in which the
products were introduced. Key hardware features and softwai e
product support are shown in the left-hand column of each
table. The Sun system and corresponding SunOS level (s) in
which the product is supported are shown across the top of
each table.
Key
x
BT

Translation
Available and supported in this SunOS release
Requires extra boot tape

The revision date of the tables in this section is 12/90

Field Engineer Handbook - Technical Volume II

OPERATING SYSTEMS

12/90

Operating Systems
SUN-4 DEPENDENCIES
System Hardware and Operating System
Dependencies ............................
Bug Fixes and Improvements . . . . . . . . . . . . . . . ..
Bundled Software Products ..................
Unbundled Software Products ................
SunLink Communications Software Products

3
3
4
4
5

SUN-3 DEPENDENCIES
System Hardware and Operating System
Dependendes ............................
Bug Fixes and Improvements . . . . . . . . . . . . . . . ..
Bundled Software Products ..................
Unbundled Software Products ................
SunLink Communications Software Products
SUN386i DEPENDENCIES
Unbundled Software Products ................
SunLink Communications Software Products

10
10

SUN-2 DEPENDENCIES
System Hardware and Operating System
Dependencies ............................
Bug Fixes and Improvements . . . . . . . . . . . . . . . ..
Bundled Software Products ..................
Unbundled Software Products ................
SunLink Communications Software Products

11
11
12
12
13

GRAPHICS HARDWARE PRODUCTS
Sun-3 Architecture ........................
Sun-4 Architecture ........................
Sun386i Architecture .......................

14
15
15

OPSYS-2

6
7
7
8
9

Field Engineer Handbook

OPERATING SYSTEMS

12/90

Sun-4 Dependencies
System Hardware and Operating System Dependencies
Sun-4 Kernel

FEATURE

Release
4.3.2

x
x
x

x

x
x
x
x
x

x

System Hardware Architecture:
Sun-4/110 & Sun-4/2xx
Sun-4/3xx
Sun-3/4xx'
System Hardware Features:
ALM2
32MB Memory Bd.
900MB Disk
327MB SCSI
Double buffering
Operating System Installation:
Remote tape installation
Diskless Sun-3 and Sun-4
installation on a Sun-4 Server"
Diskless Sun-2, Sun-3
& Sun-4 installation on
Sun-2' ", Sun-3, Sun-4 Servers
Sunupgrade from 4.0 to 4.0.3

.

..

Sun-4c Kernel

Release
4.0.3

Release
4.0.3

x
x

x
x

x
x

x

x

SunLink Channel Gateway 7.0 required .

Sun-4 servers running Sys4-3.2 can support Sun-3 clients running SunOS
Release 3.5 .
••• Sun-2 servers strongly discouraged.

Bug Fixes and Improvements
Sun-4 Kernel

FEATURE

Release
4.0.3

Release
4.3.2

QIC-24 Distribution Media
(Sun-3/Sun-4 )
SunPro make
filemerge
Subnets
SCSI Disconnect/Reconnect
SunOS ReI. 3.3 bug fixes

x

x

x
x
x
x
x

x

SunOS ReI. 3.4 kernel bug fixes
SunOS ReI. 3.4 SunView bug fixes
SunOS ReI. 3.5 bug fixes

x
x
x

Technical Volume II

Sun-4c Kernel
Release
4.0.3

x

OPSYS-3

12/90

OPERATING SYSTEMS
Sun-4 Dependencies - Continued
Bundled Software Products

Sun-4c Kernel

Sun-4 Kernel

FEATURE
SunView Rei. 1.7
SunView ReI. 1.75

Release
4.0.3

Release
4.3.2

Release
4.0.3

x
x

Unbundled Software Products
Sun-4 Kernel

FEATURE
NeWS ReI. 1.1
NSE ReI. 1.1
Cross-Compilers ReI. 2.0:
Sun-4 to Sun-2 or Sun-3
Cross-Compilers Rei. 3.0:
Cross-Compilers 3.0-C
Cross-Compilers 3.0 - FORTRAN
Cross-Compilers 3.0 - Pascal
Sun FORTRAN ReI. 1.05
Sun FORTRAN Rei. 1.2
Sun Pascal ReI. 1.05
Sun Pascal ReI. 2.0
SunlNGRES ReI. 5.1
SunUNIFY ReI. 3.0
SunSimplify Rei. 1. 1
SunGKS ReI. 2.2.1'
SunGKS Rec. 3.0
Sun58TE Rei. 1.0
SunPHIGS ReI. 1.0'
SunPHIGS ReI. 1. 1
Modula-2 ReI. 2.1
PC-NFS ReI. 3.0
PC-NFS Toolkit
SunlPC Rei. 1.2
Sun Common Lisp ReI.2 .. 1
Sun Common Lisp ReI. 3.0
SPE 1.0 for SCLisp ReI. 2.1
TranScript Rei 2.1
SunTrac ReI. 1.3
DosWindows ReI. 1.0
Pascal 2.0

.

Release
4.0.3

x

Sun-4c Kernel

Release
4.3.2

x
x

Release
4.03

x

x
x
x
x

x
x
x
x

x

x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x

x
x

x
x
x

x
x
x
x
x

SunNet License ReI. 1.0
x
Applications produce graphics only under Sunview (1) in ReI. 4.0.3 . NeWS
is not currently supported.
• 'These releases run under SunOS 4.0.3 in a "compatibility" mode .

OPSYS-4

Field Engineer Handbook

OPERATING SYSTEMS

12/90

Sun-4 Dependencies - Continued
Sun Link Communications Software Products
Sun-4 Kernel

FEATURE
IBM Connectivity Products:
BSCRJE ReI. 6.0
SCA Rei 6.0
SCG ReI. 7.0
Local 3270 ReI. 6.1
SNA 3270 Rei. 5.1
SNA Peer-to-Peer ReI. 6.0
SNA 3270 ReI. 6.1
CG3270 ReI. 6.1
DEC Connectivity Products:
ONI Release 5.1
TE100 Re1.5.1
TE100 Rei. 6.0
TE3278
ONI Re1.6.0
Standards:
X.25 ReI. 5.1
X.25 ReI. 6.0
Wide Area Networks:
IR ReI. 6.0
MCP ReI. 6.0

Technical Volume II

Release
4.0.3

Sun-4c Kernel

Release
4.3.2

Release
4.0.3

x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x

OPSYS-5

12/90

OPERATING SYSTEMS

Sun-3 Dependencies
System Hardware and Operating System Dependencies
Sun-3x
Kernel

Sun-3 Kernel

FEATURE
Release
4.0.3

Release
3.5

Release
3.4

Release
3.3

Reease
3.2

x

x

Release
4.0.3

System Hardware Architecture:
Sun-3/BO

x

x

BT

Sun-3/E

x

x

BT

Sun-3/50. 3/75. 3/1 xx. Sun-3/2xx

x

x

x

x

Sun-3/BO & Sun-3/4xx
System Hardware Features:

x

x

900MB Disk

x

x

x

327MB SCSI

x

x

x

Double buffering

x

x

x

ALM2

x
x

32MB Memory Bd.

Operating System Installation:
Remote tape installation

x

x

x

x

x

x

Diskless Sun-2 and Sun-3
installation on a Sun-3 Server

x

x

x

x

x

x

Diskless Sun-3 and Sun-4
installation on a Sun-4 Server'

x

x

Diskless Sun-2. Sun-3.

x

x

& Sun-4 installation on

Sun-2*'. Sun-3. Sun-4 Servers
Sunupgrade from 4.0 to 4.0.3

x

, Sun-4 servers running Sys4-3.2 can support Sun-3 clients running SunOS
Release 3.5.
*' Sun-2 servers strongly discouraged.

OPSYS-6

Field Engineer Handbook

OPERATING SYSTEMS

12/90
Sun-3 Dependencies - Continued
Bug Fixes and Improvements

Sun-3x
Sun-3 Kernel

FEATURE
Release
4.0.3

QIC-24 Distribution
Media (Sun-3/Sun-4)

x

3.5

Release
3.4

Release

Kernel

Release
3.3

SunPro make

x

x

x

filemerge

x

x

x

Subnets

x

x

x

x

SCSI Disconnect/Reconnect

x

x

x

x

SunOS ReI. 3.3 bug fixes

x

x

x

x

SunOS ReI. 3.4 kernel bug fixes

x

x

x

SunOS Rei. 3.4 SunView bug fixes

x

x

x

SunOS Release 3.5 bug fixes

x

x

Reease

3.2

Release
4.0.3

x

Bundled Software Products
Sun-3x
Sun-3 Kernel

Kernel

FEATURE
Release

Release

Release

Release

Reease

Release

4.0.3

3.5

3.4

3.3

3.2

4.0.3

FORTRAN-77

x

x

x'

x

pC (Pascal)

x

x

x'

x

SunView ReI. 1.7

x

x

SunView ReI. 1.75

x

, Uses the version for SunOS 3.2

Technical Volume II

OPSYS-7

12/90

OPERATING SYSTEMS

Sun-3 Dependencies - Continued
Unbundled Software Products
Sun-3x
Sun-3 Kernel

FEATURE
Release
4.0.3

NeWS ReI. 1.1
. NSE ReI. 1.0
Cross-Compilers ReI. 2.0
Sun-3 to Sun-2 or Sun-4
Cross-Compilers Rei. 3.0:
Cross-Compilers 3.0-C
Cross-Compilers 3.0 - FORTRAN
Cross-Compilers 3.0 - Pascal
Sun FORTRAN ReI. 1.0
Sun FORTRAN ReI. 1.2
Sun Pascal Rei. 2.0
SunlNGRES Rei. 5.1
SunUNIFY Rei. 3.0
SunSimplify ReI. 1.1
SunAlis ReI. 2.1
SunGKS Rei. 2.2.1'
SunGKS ReI. 3.0
Sun58TE Rei. 1.0
SunPHIGS ReI. 1.0'
SunPHIGS ReI. 1. 1
Modula-2 Rei. 2.0
Modula-2 Rei. 2.1
SunPaint ReI. 1.0"
SunWrite ReI. 1.0"
Sun Draw ReI. 1.0"
PC-NFS Rei. 3.0
PC-NFS Toolkit
SunlPC ReI. 1.2
Sun Common Lisp Re1.2.1
Sun Common Lisp ReI. 3.0
SPE 1.0 for SCLisp Rei. 2.1
TranScript Rei 2.1
SunTrac Rei. 1.3
DosWindows ReI. 1.0
SunNet License ReI. 1.0

x

Kernel

Release
3.5

Release
3.4

Release
3.3

Reease
3.2

Release
4.0.3

x
x

x
x

x
x

x

x

x

x

x

x

x
x
x

x
x
x
x

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x

x

x

x
x
x

x
x
x
x
x

x
x
x
x
x

x
x
x
x
x

x
x
x
x
x

x

x

x

x

x
x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x
x
x
x

x

x
x
x
x
x
x
x
x
x

x
x
x
x
x
x
x

x'
x
x
x
x
x
x

x

x
x
x
x

, Applications produce graphics only under Sunview (1) in Rei. 4.0.3. NeWS is not
currently supported.
"These releases run under SunOS 4.0.3 in a "compatibility" mode.

OPSYS-8

Field Engineer Handbook

12/90

OPERATING SYSTEMS

Sun-3 Dependencies - Continued
SunLink Communications Software Products
Sun-3x
Sun-3 Kernel

FEATURE

IBM Connectivitv Products:
BSC3270 ReI. 3.0
BSC3270 ReI. 6.1
BSCRJE Rei 5.0
BSCRJE ReI. 6.0
SCA ReI. 5.0
SCA Rei 6.0
SCG ReI. 7.0
Local 3270 ReI. 5.0
Local 3270 ReI. 6.1
SNA 3270 Rei. 5.0
SNA Peer-lo-Peer ReI. 5.0
SNA Peer-lo-Peer ReI. 6.0
SNA 3270 ReI. 6.1
CG3270 ReI. 6.1
DEC Connectivity Products:
DNI Release 5.0
TE100 Re1.4.0
TE100 ReI. 6.0
TE327B
DNI Re1.6.0
Standards:
DDN Rei 5.0
OSI Re1.5.2
MHS Rei. 5.2
X.25 ReI. 5.2
x.25 ReI. 6.0
Wide Area Networks:
. IR ReI. 5.0
IR ReI. 6.0
MCP ReI. 5.0
MCP Rei. 6.0

Release
3.3

Kernel
Reease

Release

3.2

4.0.3

Release

Release

4.0.3

3.5

Release
3.4

x

x

x

x

x

x

x

x

x

x

x

x

x
x

x
x

x
x

x

x

x

x

x
x
x

x
x
x

x
x
x
x

x
x

x
x

x
x
x

x
x
x
x
x
x
x

x
x
x
x

x
x
x
x

x

x
x

x

x

x

x

x

x
x

x
x'

• Nol SLJPpOrled on Sun-3/BO

Technical Volume II

OPSYS-9

OPERATING SYSTEMS

12/90

Sun386i Dependendes
Unbundled Software Products
Release
4.0.2

FEATURE

x
x
x

Sun FORTRAN ReI. 1.1 R
Sun Pascal Rei. 1.1
SunGKS ReI. 3.0
SunUNIFY ReI. 3.0
SunSimplify ReI. 1.1
Modula-2 ReI. 2.1
SunTrac ReI. 1.3
TransScriot Rei 2.1
DOS Windows Rei. 1.0
SunNet License Rei 1.0

x
x
x
x
x
x
x

SunLink Communications Software Products
FEATURE
IBM Connectivity Products:
SNA 3270 Rei. 6.1
DEC Connectivity Products:
TE100 Rei. 6.0
DNI Rel.6.0
Standards:
x.2S ReI. 6.0
Wide Area Networks:
IR Rei. 6.0

OPSYS-10

I

Release
4.0.2

I

x

I

x

I

x

I

x

I

x

Field Engineer Handbook

OPERATING SYSTEMS

12/90

Sun-2 Dependencies
System Hardware and Operating System Dependencies
SUM-2 Kernel

FEATURE

Release
3.5

Release
3.4

Release
3.3

Reease
3.2

x

x

x

x

x

x

x

Release
4.0.3

System Hardware Architecture:
Sun-2/xxx
System Hardware Features:
Double buffering
Operating System Installation:
Remote tape installation

x

x

x

x

Diskless Sun-2 and Sun-3
installation on a Sun-3 Server

x

x

x

x

Sunupgrade from 4.0 to 4.0.3

x

Bug Fixes and Improvements
Sun-2 Kernel

FEATURE

Release
4.0.3

Release
3.5

Release
3.4

x

Release
3.3

SunPro make

x

x

Subnets

x

x

x

x

SCSI Disconnect/Reconnect'

x

x

x

x

SunOS ReI. 3.3 bug fixes

x

x

x

x

x
x

x

SunOS ReI. 3.4 kernel bug fixes
SunOS ReI. 3.4 SunView bug fixes

x

x

x

SunOS Release 3.5 bug fixes

x

x

Reease
3.2

* No SCSI-3 support on Sun-2 systems

Technical Volume II

OPSYS-11

OPERATING SYSTEMS

12/90

Sun-2 Dependencies - Continued
Bundled Software Products
Sun-2 Kernel
FEATURE

Release

4.0.3

Release

Release

Release

3.3

Reease

3.2

3.5

3.4

FORTRAN-77

X

X

x'

X

pC (Pascal)

X

X

X'

X

X

X

Release

Release

SunView Rei. 1.5

X

SunView ReI. 1.7
SunView Rei. 1.75

X

'Uses the version for SunOS 3.2

Unbundled Software Products
Sun-2 Kernel

FEATURE
Release

4.0.3
NeWS Rei. 1.1
NSE ReI. 1.1
Cross-Compilers ReI. 2.0
Sun-2 to Sun-3 or Sun-4
Sun FORTRAN ReI. 1.0
Sun FORTRAN Rei. 1. 1
Sun Pascal ReI. 1. 1
SunlNGRES ReI. 5.1
SunUNIFY ReI. 3.0
SunSimplify Rei. 1.1
SunGKS Rei. 2.2.1'
SunPHIGS ReI. 1.0'
Modula-2 ReI. 2.0
SunPaint ReI. 1.0"
SunWrite ReI. 1.0"
Sun Draw Rei. 1.0"
SunlPC ReI. 1.2
Sun Common Lisp ReI. 2.1
TranScript Rei 2.1
SunTrac Rei. 1.2
DosWindows Rei. 1.0

X

x
x
x
x

x
x
x
x
x
x
x
x
x

Release

Reease

3.5

3.4

3.3

3.2

x
x

x
x

x
x

x
x

x
x

x
x

x
x

x
x
x
x
x
x
x
x
x
x
x
x
x

x
x
x
x

x
x
x
x

x
x
x
x

x
x
x
x
x
x
x
x

x

x

x
x
x
x

x
x
x
x

,

Applications produce graphics only under Sunview (1) in ReI. 4.0.3.
NeWS is not currently supported.
"These releases run under SunOS 4.0.3 in a "compatibility" mode.

OPSYS-12

Field Engineer Handbook

OPERATING SYSTEMS

12/90

Sun-2 Dependencies - Continued
SunLink Communications Software Products
Sun-2 Kernel

FEATURE

IBM Connectivity Products:
BSC3270 ReI. 3.0
BSC3270 ReI. 6.1
BSCRJE Rei 5.0
BSCRJE ReI. 6.0
Local 3270 ReI. 5.0
SNA Peer-to-Peer ReI. 6.0
CG3270 ReI. 6.1
DEC Connectivity Products:
ONI Release 5.0
TE100 Rei. 6.0
TE3278
ONI Re1.6.0
Standards:
OON Rei 5.0
OSI Rel.5.2
MHS ReI. 5.2
X.25 Rei. 5.2
x.25 Rei. 6.0
Wide Area Networks:
IR ReI. 5.0
IR ReI. 6.0
MCP Rei. 5.0
MCP Rei. 6.0

Technical Volume II

Release

Release

Release

4.0.3

3.5

3.4

Release
3.3

Reease
3.2

x

x

x

x

x

x

x

x

x

x

x

x

x
x
x
x

x
x
x
x

x
x
x
x

x

x

x

x

x

x

x
x
x
x

x
x
x

x

x
x

OPSYS-13

OPERATING SYSTEMS

12/90

Sun-3 Architecture Graphics Hardware Products
PRODUCT
BW2

3.5
standard

4.0/4.0.1

4.0.3

standard

standard

4.1
standard

CG2/CG3

standard

standard

standard

standard

CG4

standard

standard

standard

standard

CG2/CG3

standard

standard

standard

standard

standard

standard

standard

standard

GP2 1.0

GP2 1.0

GFX Rev.1

standard

CG6
GX

3.5-CG6

N/A

CG6 & GFX-A
or GFX Rev.1

standard

CGa
TC

N/A

N/A

GFX-A
or GFX Rev.1

standard

CG9/GP2

N/A

N/A

CG9 & GFX-A
or GFX Rev.1

standard

TAAC

TACC
2.02.1.
2.2. 2.3

TACC
2.02.1.
2.2. 2.3

TAAC 2.3

TACC 2.3

SunDials

N/A

Dials 1.0

GFX Rev. 1

standard

with GP/GP+

CG3/GP+/GB
CXP

CG5/GP2
CXP

GXP

OPSYS-14

Field Engineer Handbook

OPERATING SYSTEMS

12/90

Sun-4 Architecture Graphics Hardware Products
PRODUCT

Sys 4-3.2

4.0.3

4.0.3c

standard

standard

standard

standard

standard

N/A

standard

N/A

standard

standard

standard

standard

standard

standard

N/A

standard

standard

standard

standard

N/A

standard

standard

standard

standard

N/A

standard

GP21.0

GP21.0

GFX Rev.l

N/A

standard

CG6
GX

N/A

N/A

CG6 & GFX-A
or GFX Rev.l

GFX Rev.l

standard

CG8
TC

N/A

4.0-CG8' or
4.0.2-CG8

GFX-A
or GFX Rev.l

N/A

standard

CG9/GP2

N/A

4.0-CG9

CG9 & GFX-A
or GFX Rev.l

N/A

standard

TAAC

TACC
2.02.1,
2.2, 2.3

TACC
2.02.1,
2.2, 2.3

TACC 2.3

N/A

TAAC 2.3

Sun Buttons

N/A

N/A

Btn 1.0

Btn 1.0
GFX Rev.l

standard
GFX Rev.l

SunDials

N/A

Dials 1.0

GFX 1.0

GFX Rev.l

standard

4.0/4.0.1

BW2

standard

standard

CG2/CG3

standard

CG3

N/A

CG4

CG2/CG3

4.1

with GP/GP+

CG3/GP+/GB
CXP

CG5/GP2
CXP

GXP

• 4.0-CG8 is not upgradeable to SunOS 4.0.1

Sun386i Architecture Graphics Hardware Products
PRODUCT

4.0

4.0.1

4.0.2

4.0.3

standard

standard

BW2

standard

CG3

standard

standard

standard

standard

CG5 GXi

N/A

GXi

standard

standard

Technical Volume II

standard

OPSYS-1S

DIAGNOSTICS

12/90

Diagnostics
Self-Test Diagnostics .......................
Extended Diagnostics .......................
Sun386i Hardware Diagnostics . . . . . . . . . . . . . . ..
Diagnostic Executive . . . . . . . . . . . . . . . . . . . . . . ..
1.1 Diagnostic Executive Sun 2 and Sun 3 . . . . ..
1.19 Diagnostic Executive Sun386i . . . . . . . . . . . ..
1.2 Diagnostic Executive Sun 3 and 3x .
1.2 Diagnostic Executive Sun 4 . . . . . . . . . . . . . ..
1.2 Diagnostic Executive Sun 4S .............
1.2 Diagnostic Executive Sun 4c . . . . . . . . . . . . ..
1.3 Diagnostic Executive Sun 4c . . . . . . . . . . . . ..
1.4 Diagnostic Executive Sun 4c . . . . . . . . . . . . ..
Loopback Connectors . . . . . . . . . . . . . . . . . . . . . ..

Field Engineers Handbook - Technical Volume II

3
4
5
6
7
8
9
11
12
13
14
15
16

DIAGNOSTICS

12/90

This page intentionally left blank.

DIAGS-2

Field Engineer Handbook

DIAGNOSTICS

12/90

Self-Test Diagnostic
The CPU Self-Test runs in either the Normal or Diag mode.
Set the CPU DIAG/NORM switch to DIAG to enable the Diag
mode. Set the CPU DiaglNorm switch to NORM to enable the
Normal mode. Some systems do not have this capability.
The jumper or NVRAM parameter changes required to set
the Sun386i CPU board to Diag mode or to By-pass mode
are described in the CPU Configuration Section. By-pass
mode forces the CPU to skip most of the Self-Tests and go
to the Prom Monitor.
In the Normal mode, the CPU runs through a basic set of
tests and reports errors on the diagnostic LEOs. The
meanings of the failure patterns of these LEOs are not always
consistent between machine types. Refer to the appropriate
Field Service Manual and the Troubleshooting Section of this
Handbook for self-test LED error code information.
When the CPU is set to the Diag mode, the self-tests are
more extensive than in the Normal mode and include a
complete memory check. Connect an ASCII terminal to port A
to display the self-test output when the system is in Diag
mode. Use full duplex, 9600 baud, XON/XOFF, 8bits/1 stop
bit, and no parity with a null modem type cable.

Technical Volume II

DIAGS-3

12/90

DIAGNOSTICS

Extended Diagnostics
The diagnostics built into the EPROM on CPU boards
are designed to verify a working boot path so that more
comprehensive diagnostics can be loaded.
Enter "x" at the PROM Monitor prompt to display the
Extended Diagnostics menu :

>x
The Extended Diagnostics menu displays the tests available.
The user is prompted to select a test for execution. To return
to the PROM Monitor, enter "q" to the Extended Diagnostics
prompt.
EPROM space is limited. Some tests were removed from the
2.8 EPROM in November 1988 to make room for more boot
and display device drivers.
With the 2.8 EPROM, boot path tests are no longer accessed
through the Extended Diagnostics menu. They are executed
directly from the PROM Monitor prompt using the command:
>b*deviceO
where device is the appropriate disk or tape device to be
tested.
In the Sun-4c, the PROM Monitor has changed to the Open
PROM Toolkit to take advantage of the FORTH programming
language. Refer to the EPROM and NVRAM Information in the
CPU section of Configurations for more information.

DIAGS-4

Field Engineer Handbook

DIAGNOSTICS

12/90

Sun386i Hardware Diagnostics
The Sun386i Hardware Diagnostics are a diagnostic tool for
non-technical Sun386i users.
The Hardware Diagnostics are an automated subset of the
Diagnostic Executive. These tests are used to find a FRU level
failure. The diagnostic prints an error indication, reports the
probable subsystem that needs help, and returns control to
the PROM Monitor if a problem is found.
To execute the Hardware Diagnostics, halt the system, install
the Hardware Diagnostic diskette in the floppy drive, and cycle
the power.
The system configuration is compared with the configuration
information stored in NVRAM. The user is prompted to answer
questions if a conflict exists between the system configuration
and the contents of NVRAM. All the tests are then displayed
with an indication of which tests will be executed.
Select the tests with the return key and toggle the Yes/No
choice with the space key. When the last return is entered,
the user is prompted to verify the configuration. The tests are
then run to completion or until an error occurs.

Technical Volume II

DIAGS-5

DIAGNOSTICS

12/90

Diagnostic Executive
The Diagnostic Executive (Exec) provides a single, unified
diagnostic environment with one user interface. The
diagnostic tests reside in individual programs that work
through the Exec platform. The platform provides a consistent
interface and multitasking capabilities. Some features are:

Multiple Consoles
The Exec can run from any control terminal. This may be a
monitor, serial port, or a remote console.
Error Logging
The Exec provides the ability to capture error messages into
a logfile. The logfile may reside on a local disk or on a
server.
Script Execution
Command scripts can be used to drive the menus without
further user intput.
Remote Execution
The Exec has the ability to perform remote diagnostics over
a modem connected to a Serial Port or over Ethernet.
Due to the complexity of the Exec, individual tests will not be
discussed here. Refer to the Sun Diagnostic Executive User
Manuals for additional information. Tables of Contents for the
Exec are included in this section.
Loopback connectors are required for some tests. The
loopback connectors are described at the end of this section.

DIAGS-6

Field Engineer Handbook

DIAGNOSTICS

12/90

1.1 Diagnostic Executive
Sun-2 and Sun-3
Table of Contents
NAME

FILE #

DESCRIPTION

(HEX)

Sun-2 Boot Block
Sun-3 Boot Block
Table of Contents
extract exec
Copyright
exec
diags
color2.exec
color3.exec
cpu.exec
eeptool.exec
ether. exec
exectest. exec
fpa.exec
gp1.exec
kb.exec
mcp.exec
mem.exec
mouse.exec
mti.exec
scsisub.exec
sky2.exec
smd.exec
tape.exec
video. exec
vidmon.exec
vme3.exec
netcon
logfile
eccmem3.diag
cache3.diag
tarfile
Copyright

Technical Volume II

0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C

10
1E
1F
20

Sun-2 boot file
Sun-3 boot file
Contains list of contents of tape
Script to copy diagnostics to disk
Textfile containing copyright notice
Diag Exex for Sun-2 and Sun-3
Diagnostic Menu and File names
Sun-2 Color Diagnostic
Sun-3 Color Diagnostic
Sun CPU Diagnostic
EEPROM programming tool
Sun Ethernet Diagnostic
Exec Verification Suite
Sun-3 FPA Diagnostic
Graphics Processor1 Diagnostic
Sun Keyboard Diagnostic
Sun ALM2/MCP Board Diagnostic
Sun Memory Diagnostic
Sun Mouse Diagnostic
Sun MTIIALM Board Diagnostic
Sun SCSI Diagnostic
Sky 2 Diagnostic
Sun SMD Diagnostic
1/2" Tape Diagnostic
Sun Video Diagnostic
Sun Video Monitor Diagnostic
Sun-3 VME Diagnostic
Network Console Program
Error Log File
Standalone ECC memory diagnostic
Standalone cache memory diagnostic
TAR image of executables
Textfile containing copyright notice

DIAGS-7

12/90

DIAGNOSTICS

1.19 Sun386i Diagnostic Executive
Sun386i
Table of Contents
NAME
cpu
tip
mem
vid
Disk
tape
eth
tp
kb
mou

DESCRIPTION
CPU Diagnostic Menu
Floppy Diagnostic Menu
Memory Diagnostic Menu
Video Diagnostic Menu
Fixed Disk Diagnostic Menu
Cartridge Tape Diagnostic Menu
Ethernet Diagnostic Menu
Floating-Point Diagnostic Menu
Keyboard Diagnostic Menu
Mouse Diagnostic Menu

Note
The 1.19 Sun386i Diagnostic Executive was replaced with the 1.26
Sun386i Diagnostic Executive in March 1989. The 1.26 Diag Exec is not
available.

DfAGS-8

Field Engineer Handbook

DIAGNOSTICS

12/90

1.2 Diagnostic Executive
Sun-3 and Sun-3x
Table of Content
NAME

FILE #

DESCRIPTION

(Decimal)

tpboot. sun3
tpboot. sun3x
toc
extract_exec
Copyright
exec
exec3x
diags
cg6.exec
cg8.exec
cg9.exec
color. exec
cpcache.exec
cpu.exec
eeptool.exec
ether2.exec
exectest. exec
fdc.exec
fddi.exec
fpa.exec
fpa_plus.exec
gp1.exec
gp2.exec
hsi.exec
iocache.exec
ipi.exec
kb.exec
mcp.exec
mem.exec
mempar.exec
mouse. exec
mti.exec
scsisub.exec
espscsi.exec
smd.exec
taac.exec
tape.exec
video.exec
vidmon.exec
vme3.exec

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
17
18
19
20
21
22
23
24
26
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41

Technical Volume II

Enables Sun-3 boot from tape
Enables Sun-3x boot from tape
Contains list of contents of tape
Script to copy diagnostics to disk
Textfile containing copyright notice
Diag Exec for Sun-3 architecture
Diag Exec for Sun3/400 Series and 3/80
Diagnostic Menu and File names
P4 Color Frame Buffer Diagnostic
P4 24-Bit Frame Buffer Board Diagnostic
VME 24-Bit Frame Buffer Board Diagnostic
Generic VME Color Board Diagnostic
Sun-3/400 Series Cache Diagnostic
Sun CPU Diagnostic
EEPROM programming tool
Ethernet II Diagnostic
Exec Verification Suite
On-Board Floppy Disk Controller Diagnostic
FOOl Board Diagnostic
Sun-3 Floating Point Accelerator Diagnostic
Sun-3/80 Floating Point AcceleratorPlus Diag
Graphics Processor1/Graphics Buffer Diag
Graphics Processor2 Diagnostic
High Speed Serial Board Diagnostic
Sun-3/400 Series I/O Cache Diagnostic
IPI Disk Subsystem Diagnostic
Sun Keyboard Diagnostic
Sun ALM2/MCP Board Diagnostic
Sun Memory Diagnostic
Sun 3/80 Parity Memory Diagnostic
Sun Mouse Diagnostic
Sun MTI/ALM Board Diagnostic
SCSI Subsystem Diagnostic
3/80 Extended SCSI Diagnostic
Sun SMD Diagl]ostic
T AAC-1 Accelerator Diagnostic
Pertec 1/2-inch Tape Diagnostic
Sun Video Diagnostic
Sun Video Monitor Diagnostic
Sun VME Diagnostic

DIAGS·9

DIAGNOSTICS

12/90

1.2 Diagnostic Executive

Continued

Sun-3 and Sun-3x
Table of Content
NAME

FILE #

DESCRIPTION

(Decimal)

netcon
42
logfile
42
eccmem3.diag 43 (Ox2C)
cache3.diag
44 (Ox2D)
Copyright
45

Network Console Program
Error Log File
Standalone ECC Memory Diagnostic
Standalone Cache Memory Diagnostic
Textfile containing copyright notice

References
1. Read This First SunDiagnostic Executive, Version 1.2, 800-3288-10
2. SunDiagnostic Executive User's Guide for MC68020, MC68030, and
SF90101U (SPARC) Based Systems, 800-3273-10.

DIAGS-10

Field Engineer Handbook

12/90

DIAGNOSTICS

1.2 Diagnostic Executive
Sun-4
Table of Contents
NAME

FILE

DESCRIPTION

(DECIMAL)

tpboot.sun4
Copyright
toc
extract exec
Copyright
exec4
diags4
cg6.4exec
cg8.4.exec
cg9.4.exec
color4.exec
cpcache4.exec
cpu4.exe
eeptool4.exec
ether4.exec
ether2.4. exec
exectest4.exec
fddi4.exec
fpu4.exec
gp 1.4. exec
gp2.4.exec
hsi4.exec
ipi4.exec
kb4.exec
mcp4.exec
mem4.exec
mouse4.exec
mti4.exec
scsisub4.exec
espscsLexec
smd4.exec
taac4.exec
tape4.exec
vide04.exec
vidmon4.exec
vme4.exec
netcon4
logfile
eccmem4.diag 38
cache4.diag
39
Copyright

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
(Ox27)
(Ox28)
40

Technical Volume II

Enables boot from tape
Textfile containing copyright notice
Contains list of contents of tape
Script to copy diagnostics to disk
Textfile containing copyright notice
Diag Exec for Sun-4 architecture
Diagnostic Menu and File names
P4 Low-Eng Graphics Accelerator
P4 24-Bit Frame Buffer Board Diagnostic
VME 24-Bit Frame Buffer Board Diagnostic
Generic VME Color Board Diagnostic
4300 CPU Cache Diagnostic
CPU Board Diagnostic
EEPROM programming tool
Ethernet Diagnostic
2nd Ethernet Diagnostic
Exec Verification Suite
FDDI Board Diagnostic
Floating Point Unit Diagnostic
Graphics Processor1/Graphics Buffer Diag
Graphics Processor2 Diagnostic
High Speed Serial Board Diagnostic
IPI Disk Subsystem Diagnostic
Sun Keyboard Diagnostic
Sun ALM2/MCP Board Diagnostic
Sun Memory Diagnostic
Sun Mouse Diagnostic
Sun MTI/ALM Board Diagnostic
Sun SCSI Subsystem Diagnostic
4300 Extended SCSI Diagnostic
Sun SMD Diagnostic
TMC-1 Diagnostic
Pertec 1/2-inch Tape Diagnostic
Sun Video Circuit Diagnostic
Sun Video Monitor Diagnostic
Sun VME Diagnostic
Network Console Program
Error Log File
Standalone ECC Memory Diagnostic
Standalone Cache Memory Diagnostic
Textfile containing copyright notice

DIAGS-11

DIAGNOSTICS

12/90

1.2 Diagnostic Executive Sun-4S
SPARCsystems 300/400
Table of Contents
NAME

FILE

DESCRIPTION

(DECIMAL)

tpboot.sun4
0
Copyright
1
toc
2
extract exec
3
Copyright
4
exec4
5
diags4
6
cpu4.exe
7
mem4.exec
8
cpcache4 300.exec 9
cpcache4=400. exec 10
iocache4.exec
11
video4.exec
12
kb4.exec
13
14
mouse4.exec
15
cg6.4exec
cg8.4.exec
16
cg9.4.exec
17
color4.exec
18
eeptool4.exec
19
espscsLexec
20
ether2.4.exec
21
ether4.exec
22
23
exectest4.exec
fddi4.exec
24
fpu4.exec
25
gpl.4.exec
26
gp2.4.exec
27
hsi4.exec
28
ipi4.exec
29
30
mcp4.exec
mti4.exec
31
32
scsisub4.exec
smd4.exec
33
taac4.exec
34
35
tape4.exec
36
vme4.exec
netcon4
37
logfile
38
eccmem4.diag
39
cache4.diag
40
Copyright
41

Enables boot from tape
Texttile containing copyright notice
Contains list of contents of tape
Script to copy diagnostics to disk
Textfile containing copyright notice
Diag Exec for Sun-4s architecture
Diagnostic Menu and File names
CPU Board Diagnostic
Memory Diagnostic
4300 Cache Diagnostic
4400 Cache Diagnostic
4400 I/O Cache Diagnostic
Video Circuit Diagnostic
Keyboard Diagnostic
Mouse Diagnostic
P4 Low-Eng Graphics Accelerator
P4 24-Bit Frame Buffer Board Diagnostic
VME 24-Bit Frame Buffer Board Diagnostic
Generic VME Color Board Diagnostic
EEPROM programming tool
4300 CPU Extended SCSI Diagnostic
Ethernet II Board Diagnostic
Sun Ethernet Diagnostic
Exec Verification Suite
FOOl Board Diagnostic
Floating Point Diagnostic
Graphics Processor1/Graphics Buffer Diag
Graphics Processor2 Diagnostic
High Speed Serial Board Diagnostic
IPI Disk Subsystem Diagnostic
Sun ALM2/MCP Board Diagnostic
Sun MTI/ALM Board Diagnostic
Sun SCSI Subsystem Diagnostic
Sun SMD Diagnostic
TAAC Diagnostic
Tape Diagnostic
VME Diagnostic
NETCON
LOGFILE
ECC Memory Diagnostic
Cache Diagnostic
Textfile containing copyright notice

Reference
SPARCsystems 3001400 Series SunDiagnostic Executive User's Guide
Addenda, 800-3493-10.

DIAGS-12

Field Engineer Handbook

DIAGNOSTICS

12/90

1.2 Diagnostic Executive
Sun-4c
Table of Contents
NAME

FILE

DESCRIPTION

(DECIMAL)

tpboot.sun4c
Copyright
toc
extract_exec
Copyright
exec4c
diags4c
cache4c.exec
cpu4c.exec
ether4c.exec
fdc4c.exec
fpu4c.exec
kbm4c.exec
mem4c.exec
scsi4c.exec
cg6.4c.exec
video4c.exec

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Enables boot from tape
Textfile containing copyright notice
Contains list of contents of tape
Script to copy diagnostics to disk
Textfile containing copyright notice
Diag Exec for Sun-4c architecture
Diagnostic Menu and File names
Cache Memory Diagnostic
CPU Board Diagnostic
Ethernet II Board Diagnostic
Floating Point Unit Diagnostic
Floating Point Unit Diagnostic
Keyboard Diagnostic
Memory Diagnostic
SCSI Subsystem Diagnostic
CG6 Diagnostic
Video Diagnostic

Note
The 1.2 Diag Exec supports the Sun-4/60.
Reference
SunDiagnostic Executive 1.2C User's Guide for the SPARCstation 1,
800-3414-10.

Technical Volume \I

DIAGS-13

DIAGNOSTICS

12/90

1.3 Diagnostic Executive
Sun-4c
Table of Contents
NAME

FILE

DESCRIPTION

(DECIMAL)

tpboot.sun4c
Copyright
toc
extract_exec
Copyright
exec4c
diags4c
cache4c.exec
cpu4c.exec
ether4c.exec
fdc4c.exec
fpu4c.exec
kbm4c.exec
mem4c.exec
scsi4c.exec
cg6.4c.exec
vide04c.exec
n/a
n/a
Copyright

o
1

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
18
19
20

Enables boot from tape
Textfile containing copyright notice
Contains list of contents of tape
Script to copy diagnostics to disk
Textfile containing copyright notice
Diag Exec for Sun-4c architecture
Diagnostic Menu and File names
Cache Memory Diagnostic
CPU Board Diagnostic
Ethernet II Board Diagnostic
Floating Point Unit Diagnostic
Floating Point Unit Diagnostic
Keyboard Diagnostic
Memory Diagnostic
SCSI Subsystem Diagnostic
CG6 Diagnostic
Video Diagnostic
TAR image of executables
TAR image of Development Platform
Textile containing copyright notice

Note
The 1.3 Diag Exec supports the Sun-4/20, Sun-4/40, Sun-4/60, and
Sun-4/65.
Reference
SunDiagnostic Executive 1.3 User's Guide for SPARCstations,
800-5314-10.

DIAGS-14

Field Engineer Handbook

12/90

DIAGNOSTICS

1.4 Diagnostic Executive
Sun-4c
Table of Contents
NAME

FILE

DESCRIPTION

(DECIMAL)

exec4c
tpboot.sun4c
toc
extract_exec
Copyright
exec4c
diags4c
cache4c. exec
cpu4c.exec
ether4c.exec
fdc4c.exec
fpu4c.exec
kbm4c.exec
mem4c.exec
scsi4c.exec
cg6.4c.exec
vide04c.exec
spif4c.exec
zebra4c.exec
cg12.4c.exec
snapshot4c.exec
n/a
n/a
Copyright

o
1
2

3
4
5
6
7
8

9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

exec4c for OBP2
Enables boot from tape
Contains list of contents of tape
Script to copy diagnostics to disk
Textfile containing copyright notice
Diag Exec for Sun-4c architecture
Diagnostic Menu and File names
Cache Memory Diagnostic
CPU Board Diagnostic
Ethernet II Board Diagnostic
Floating Point Unit Diagnostic
Floating Point Unit Diagnostic
Keyboard Diagnostic
Memory Diagnostic
SCSI Subsystem Diagnostic
CG6 Diagnostic
Video Diagnostic
Serial Parallel Controller Diagnostic
SPARCprinter Board Diagnostic
CG12 Video Diagnostic
Video Frame Capture Diagnostic
TAR image of executables
TAR image of Development Platform
Texfile containing copyright notice

Note
The 1.4 Diag Exec supports the Sun-4/20, Sun-4/40, Sun-4/60,
Sun-4/65, and Sun-4/75.

Technical Volume II

DIAGS-15

DIAGNOSTICS

12/90

Loopback Connectors
RS-232/RS-423
PART #
540-1281-01
540-1558-01

RS-449
PART #
540-1559-01

540-1309-01

SYSTEM BOARDS
CPU,SCSI,SCP ,ALM
CPU, SCSI, ALM, ALM-2
SCP, MCP, SBus SPC

SYSTEM BOARDS
MCP,SCP

SCP

CONNECT PINS
2-3
4-5
6-20
2-3
4-5
6-8-20
17-24

CONNECT PINS
4-6
22-24
7-9
25-27
11-12-13
29-30-31
17-8
35-26
4-6
7-9
11-12
17-8
22-24
25-27
29-30
35-26

Parallel Port

PART #
540-1560-01

SYSTEM BOARDS
ALM-2

501-1196-01

IPC, Sun386iJ150/250

DIAGS-16

CONNECT PINS
1-10
12-2-4-6-8
13-3-5-7-9
5-15
6-13
7-12
8-10
9-11

Field Engineer Handbook

12/90

DIAGNOSTICS

Loopback Connectors - Continued

SCSI Connector Type DD-50SA
PART #
501-1344-01

SYSTEM BOARDS

CONNECT PINS

Sun-3/50,Sun-3/60

38-16
36-14
44-12
32-10
48-8
42-6
46-4
50-2
40-18

Sun386i/150/250

Sun386i Serial Port A
PART #

SYSTEM BOARDS

CONNECT PINS

501-1343-01

Sun386i1150/250

2-3
4-5
6-7

Sun386i Color Frame Buffer Keyboard/Mouse
PART #

SYSTEM BOARDS

CONNECT PINS

501-1341-01

Sun386i1150/250

1-8
2-3

Sun386i Monochrome Frame Buffer Keyboard/Mouse
PART #

SYSTEM BOARDS

CONNECT PINS

501-1342-01

Sun386i1150/250

1-8
2-3

Technical Volume II

DIAGS-17

12/90

DIAGNOSTICS
Loopback Connectors - Continued
SBus Printer Board
PART #

DESCRIPTION

530-1683-01
530-1694-01

Parallel Port to Video Port Loopback Cable
Video Port Loopback Test Plug

SBus High Speed Serial Interface (HSI/S)
PART #
370-1381-01
370-1383-01

DESCRIPTION
96-Pin High-Density Loopback Connector
RS-530 Loopback Test Plug

SBus Serial Parallel Controller (SPC)
PART #
540-1701-01
540-1558-01

DIAGS-18

DESCRIPTION
96-Pin High-Density Loopback Connector
RS-232/RS-423 Loopback Test Plug

Field Engineer Handbook



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Create Date                     : 2015:01:18 10:54:29-08:00
Modify Date                     : 2015:01:18 10:16:36-08:00
Metadata Date                   : 2015:01:18 10:16:36-08:00
Producer                        : Adobe Acrobat 9.55 Paper Capture Plug-in
Format                          : application/pdf
Document ID                     : uuid:6c4556f0-1a91-584a-9f91-411e8f34d409
Instance ID                     : uuid:1a2b0da5-76fe-7142-8477-58d62e64924a
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 338
EXIF Metadata provided by EXIF.tools

Navigation menu