Lesman It's On Fire Combustion Instrumentation Catalog B1048 Cat2008

User Manual: B1048

Open the PDF directly: View PDF PDF.
Page Count: 32

Lesman Chronicle
VOLUME BCS-2008 • LESMAN INSTRUMENT COMPANY
With our partners at
Honeywell, Maxon, Fireye, and
Kromschroder, we can provide
you a one-stop source for all
your combustion needs.
ITS ON FIRE!
...Are you willing to risk
worker safety for the
chance to keep your
boiler, furnace, thermal
oxidizer, or process
heater running?
WHY GAMBLE?WHY GAMBLE?
ame safeguard control
products let you maximize
process availability under
safe operating conditions.
On-Site Training
Lecture and hands-on sessions
taught by our factory-trained
product specialist.
Classes customized
to focus on your
specific interests.
More on
page 3!
Take a look inside: From burners and controls, flame detectors, and amplifiers to valves
and switches for pressure and temperature, Lesman has the products and the factory-
trained staff to help you get the right fit for a finely-tuned combustion system.
Need portable monitors for combustion efficiency? We’ve got those, too!
Seeing
Dollar
$ign$?
For more, check out
Honeywell’s ControLinks™
linkageless fuel air ratio
control system on page 10.
In this day and age, who’s
NOT concerned about
saving time, energy and
money? But where do you
start? How about with
reduced fuel costs? Or
reduced downtime?
Did you know...
• Mechanicallinkagesdon’t
always provide precise fuel-
air ratio control.
• Youcouldbespending
10% to 30% more on fuel
than necessary.
• Youcanreduceserviceand
downtime by replacing
your mechanical cam and
linkage systems.
Coming Soon!
Flame Safeguard and Burner Control Systems Catalog
1. Manual shutoff cock
2. Gas pressure regulator
3. Low pressure interlock
4. Motorized gas valve manual reset
5. Control valve operator
6. High gas pressure interlock
7. Test cock
8. Pilot gas cock
9. Pilot pressure regulator
10. Pilot solenoid valve
11. Gas pilot burner assembly
12. Solid-state ignition transformer
13. Flame detector
14. Primary control relay mounting base
15. High limit safety shutdown
16. Thermocouple leadwire
17. Thermocouple sensor
18. Burner valve controller
19. Main gas valve operator (automatic)
20. Vent valve (normally open)
Typical Single Burner Furnace
with Flame Safeguard System
See
What’s Inside? Page
Actuators
Honeywell Modutrol IV Low-Torque Rotary Actuator Motors .......................... 13
Honeywell V4055 On-Off Gas Valve Actuator ......................................................... 14
Kromschroder IC20/IC40 Valve Actuators ................................................................ 19
Burner Control Systems
Fireye BurnerLogix Integrated Burner Management System ........................... 19
Fireye Flame Monitor Burner Control System ........................................................ 20
Fireye MicroM Flame Safeguard Burner Control System .................................... 18
Fireye MB Industrial Multiburner Flame Safeguard System .............................. 21
Honeywell 7800 Series Microprocessor-Based Burner Controls ...................4–5
Honeywell ControLinks™ Linkageless Fuel Air Ratio Controls ..................10–11
Honeywell RA890 Protectorelay® Electromechanical Primary Control ........ 12
Kromschroder Flame Relays and Burner Control Modules.........................22–23
Maxon SMARTFIRE® Intelligent Combustion Control System .......................... 15
Flame Detectors and Amplifier Modules
Fireye Flame Scanners .................................................................................................... 20
Fireye 65UV5 Integrated Flame Scanner with Internal Flame Relay .............. 21
Honeywell R78 Series Flame Signal Amplifiers .........................................................6
Honeywell Flame Detectors........................................................................................8–9
Kromschroder UVS8T Ultraviolet Flame Detector ................................................ 23
Industrial Burners
Maxon Industrial Burners........................................................................................16–17
See
What’s Inside? Page
Pressure Controls
Honeywell P7810C Pressuretrol® Line Voltage Pressure Controller ............... 11
Honeywell C6097 Safety Limit Switches .................................................................. 12
Honeywell L404F Pressuretrol® Operating Controls ........................................... 12
Kromschroder DG Pressure Switches for Gas Applications ............................... 24
Valves
ASCO Safety Shutoff Solenoid Valves for Combustion Systems ...................... 27
Honeywell V5055 Gas Safety Shutoff Valves ........................................................... 14
Honeywell V51E Firing Rate Gas Valves .................................................................... 14
Kromschroder BV Butterfly Valves .............................................................................. 25
Kromschroder Valvario® VAS Safety Shutoff Solenoid Valves ........................... 26
Maxon Control Valves and Safety Shutoff Valves .................................................. 15
Combustion Monitors and Gas Detectors
COSA Zircomat In-Situ Stack Gas Oxygen Analyzer ............................................. 28
Testo Combustion Analyzers from RAECO Rents! ................................................. 29
TSI CA-Calc 6213 Combustion Analyzer from RAECO Rents! ............................ 29
Portable Combustible Gas Detectors from RAECO Rents! ..........................30–31
Burner Control Accessories
Fireye MicroM Subbase Mounting Adapters .......................................................... 18
Honeywell 7800 Series Burner Control Plug-In Modules .................................6–7
Honeywell Q7800 Wiring Subbases ..............................................................................5
© 2008 Lesman Instrument Company Bensenville IL. All Rights Reserved.
Due to contractual agreements with our manufacturers, some items in this
catalog may not be available in all geographic areas or markets. Prices are
current as of publication date, and are subject to change without notice.
3
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
IT’S ON FIRE
CATALOG 2008
Meet Dan...
Dan Weise, Lesman product spe-
cialist, instructs our customers on
process instrumentation theory,
hardware and software.
Dans recent courses have in-
cluded Honeywell UDC controllers,
Trendview and X-Series paperless
recorders, and Siemens SIMATIC
PDM HART software. Other course
curricula include basics of instru-
mentation (temperature, pressure, level, and flow) and
basics of Modbus protocol.
Dan has been involved in all facets of data acquisition and
process instrumentation, from sales and commissioning to
service and product support since 1978. He’s a long-time
member of ISA, and has been with Lesman since 1988.
In his words, Dan is the guy “who reads all the manuals
nobody else reads.” In our customers words, he’s the trainer
to call if you want to cut to the SO WHAT of instrumenta-
tion,” so its easy to understand.
Call 800-953-7626 to schedule
your Lesman U combustion training!
Combustion Systems Training
At Lesman, our goal is to make sure you get the right product, understand how it
works, make sure it’s installed properly, and get the most out of it. To help you
with that, we’ve created a set of classes to teach you what you need to know
about combustion systems, burner controls, and flame safety.
Courses are done in a lecture style with question/answer periods. Where
necessary, they include some hands on examples. Classes can be held at your plant
or in a Lesman Training Center, and can be customized to meet your needs. Heres
a sample of what you can expect from our Lesman U course on combustion.
p Lesson 1: When is Flame Safety Required?
Types of applications
Basics of ame detection
Introduction to basic burner systems and terminology
Main functions of ame safety controls
A fully implemented burner system
p Lesson 2: Burner Controls
Four categories: Flame switches, primary controls, programmers,
microprocessor control systems
Functions of ame safety systems: System checks, burner system sequencing,
supervisory functions and shutdown
p Lesson 3: Advanced Flame Safety Control Programmers
System components
System functions and applications
p Lesson 4: Advanced Flame Safety Concepts
Valve proving systems
Linkageless control systems (Honeywell ControLinks™)
Energy savings with pulse ring
p Lesson 5: Gas Trains and Valves
Expanded Combustion Product Lines to Serve You Better!
Dear Friends,
As you can see in this catalog, we’ve expanded our product offering to include combustion solutions.
With all that you hear about going green”, we thought it would be helpful to bring you products that
can help improve burner efficiency and reduce energy costs. It doesn’t matter if you have a thermal
oxidizer, boiler, process heater, kiln or furnace, we’ve got products to help improve your burner efficiency
and use less natural gas or heating oil. No matter how big or how small the burner, we’ve got your solu-
tion for energy savings.
If its safety your interested in, we have flame safety controls to help you meet all of your insurance
requirements and keep your workers safe. Lighting burners with flares isn’t safe, and neither is running a
process without the controls that ensure proper startup and shutdown sequences.
If you no longer have “the folks that know flame safety on staff, give us a call. Our specialists will make sure that your upgrades
meet all codes and keep your people safe. Don’t let something as simple as flame safety controls jeopardize your people or
shut down your process.
Need to focus on reducing greenhouse” gases? We’ve teamed up with vendors that have solutions to reduce NOx and other
environmental pollutants. Through innovative burners and sensors, we’ve got you covered. And with our ownership in RAECO,
we can even help measure and document stack gas emissions to help you comply with EPA rules.
We even have the expertise to help you implement flame safety or burner control systems. So, if you’d like to do some upgrades
to save energy costs, but don’t have either the time or expertise, just give us a call and let us know. Our partners have years of
experience and can minimize downtime, maximize your uptime, and do it safely and professionally.
You shouldn’t keep walking by your old controls that need replacing. Theres no need for an unplanned furnace or boiler
“relocation that can happen because your old controls simply don’t work. Being safe is best for you and your people, so give us
a call and we’ll help you start upgrading.
Sincerely,
Mike DeLacluyse
Watch our website for even
more helpful tips and product
information on ame safety
and burner control products.
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
4
V 10.2008
BURNER
CONTROLS
Microprocessor-Based Burner Controls
Microprocessor-based integrated primary burner control for automatically fired
gas, oil, coal, or combination fuel single burner applications.
Five LEDs for sequence information
Closed loop logic test, expanded safe-start check, internal hardware status monitoring and tamper-resistant
timing and logic
Valve proving feature tests valve seat integrity to detect a leak greater than 0.1% of burner input capacity
Selectable recycle/lockout on loss of ame
UL, CSA, FM, FCC approved
Required components: Q7800 universal wiring subbase, R78 series flame signal ampli-
fier, S7800A1142 keyboard display module (shown) for advanced diagnostics and to
set up valve proving
RM7840 Programming Control Unit for Forced-Air Burners
Flame Establishing Period Catalog
Pilot Main Interlocks Number Price
4 or 10 seconds 10, 15, or 30 seconds, or intermittent Running and low-fire (LHL-LF) RM7840G1022 $1805.30
4 or 10 seconds 10 or 15 seconds Lockout, low-fire and high-fire (LHL-LF&HF) RM7840L1075 2150.57
Programming control with valve proving for automatically fired gas-, oil-, coal-, or combination
fuel single-burner applications.
Interrupted pilot type
Airow check feature
Valve proving feature tests valve seat integrity to detect a leak greater than 0.1% of burner input capacity
Five LEDs provide sequence information. Power LED blinks fault code on Lockout.
CSA, FM, and UL approved
Required components: Q7800 universal wiring subbase, R78 series flame signal amplifier,
ST7800A plug-in purge timer cards, S7800A1142 keyboard display module for advanced
diagnostics, and to set up valve proving
Model Selection Guide
RM7890 On-Off Primary Control Unit for Forced-Air Burners
Model RM7840 RM7890 RM7895 RM7898
Control Type Programming On-O Primary On-O Primary On-O Primary
Added
Function
Selectable Pre-Purge Timing,
Air Flow Check
Units Available with Valve
Proving (VPS)
Selectable Pre-Purge Timing Selectable Pre-Purge Timing,
Shutter Drive, Programmable
Post-Purge, Valve Proving
Required
Components
Q7800 Wiring Subbase
R78 Flame Signal Amplier
ST7800 Purge Timer Card
S7800A1142 Keyboard Display
(for VPS)
Q7800 Wiring Subbase
R78 Flame Signal Amplier
S7800A1142 Keyboard Display
(for VPS)
Q7800 Wiring Subbase
R78 Flame Signal Amplier
ST7800 Purge Timer Card
Q7800 Wiring Subbase
R78 Flame Signal Amplier
ST7800 Plug-In Purge Timer
Card, S7800A1142 Keyboard
Display (for VPS)
Choosing the Right Honeywell 7800 Series Burner Control
Flame Establishing Period Pilot Catalog
Pilot Main Type Special Features Number Price
4 or 10 seconds Intermittent Intermittent RM7890A1015 $482.49
4 or 10 seconds Intermittent Intermittent Shutter Drive Capability RM7890B1014 506.27
4 or 10 seconds Intermittent Intermittent Valve Proving (VPS) Check Feature, Blinking LED Fault Annunciation RM7890A1056 435.25
4 or 10 seconds Intermittent Intermittent Shutter Drive Capability, VPS Check, Blinking LED Fault Annunciation RM7890B1048 432.90
Model Selection Guide
5
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
Select either the panel-mount
or burner-mount version of the
Z7800A,B 22-terminal universal
wiring subbase to accommodate your 7800 series relay
module. Both are fully compatible with all relay mod-
ules, to let you specify a wiring termination approach
that meets your application requirements.
Microprocessor-based integrated primary burner control for automatically
fired gas, oil, or combination fuel single burner applications.
On/off primary control with prepurge
Five LEDs for sequence information
Airow switch check
Selectable relight or lockout on loss of ame
Optional local or remote annunciation of operation and fault information, remote reset capability
Required components: Q7800 universal wiring subbase, R78 series flame signal
amplifier, ST7800 plug-in purge timer card
RM7895 On-Off Primary Control Unit for Forced-Air Burners
Flame Establishing Period Pilot Delayed Catalog
Pilot Main Type Airflow Check Main Valve Interlocks Number Price
4 or 10 seconds Intermittent Intermittent No No Selectable RM7895A1014 $643.51
4 or 10 seconds Intermittent Intermittent Dynamic No Selectable RM7895B1013 643.51
4 or 10 seconds 10 Seconds Interrupted Dynamic Yes Selectable RM7895D1011 832.29
Model Selection Guide
Microprocessor-based integrated primary burner control for automatically
fired gas, oil, or combination fuel single burner applications.
On/off primary control
Programmable post purge and valve proving feature available through keyboard display module
Five LEDs for sequence information, power LED blinks fault code on safety shutdown
Airow switch check and shutter drive output
Selectable recycle or lockout on loss of airow or ame
Local or remote annunciation of operation and fault information
Required components: Q7800 universal wiring subbase, R78 series flame signal
amplifier, ST7800 plug-in purge timer card, S7800A1142 keyboard display module
RM7898 On-Off Primary Control Unit with Valve Proving
Flame Establishing Period Pilot Catalog
Pilot Main Type Special Features Number Price
4 or 10 seconds Intermittent or Selectable Shutter drive output, programmable post purge, valve proving RM7898A1000 $569.44
10 seconds
Model Selection Guide
Q7800A or B Wiring Subbases for RM7800 Burner Controls
Model Selection Guide
Catalog
Description Number Price
22 Terminal Universal Wiring Subbase
Panel Mount Q7800A1005 $36.56
Burner/Wall Mount Q7800B1003 36.56
Learn more about Honeywell burner controls and ame safeguard products
online at www.lesman.com
Download specication datasheets, installation instructions, wiring diagrams and
more. Most products available to buy through our secure online store.
BURNER
CONTROLS
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
6
V 10.2008
Flame signal strength 0.0 to 5.0 VDC
Test jacks measure amplier signal voltage
Dynamic Ampli-Check™ or Self-Check rectication available, with safety shut-
down on amplifier or system failure
UL, CSA, FM approved
Solid-state flame signal amplifiers detect the presence of flame
in response to a signal from a rectifying, ultraviolet, or infrared flame detector.
Dynamic Ampli-Check™ circuitry tests flame amplifier during burner operation; 7800 series
relay module locks out on safety shutdown with amplifier failure.
Dynamic Self-Check Rectification Ampli fier and Dynamic Self-Check Ultraviolet Amplifier
test electronic components in the flame detection system 10 to 12 times per minute. The 7800
series relay module locks out on safety shutdown with flame detection system failure.
R7849A flame detectors should be used only on burners that cycle on and off at least once
every 24 hours. Appliances with burners that remain on for 24 hours or longer should use ultra-
violet flame detection systems (C7012E/F detector and R7847C amplifier or C7076A detector
and R7886A amplifier).
R78 Series Flame Signal Amplifier Modules
Purge timers let you purge unburned fuels from the combustion chamber. The
plug-in cards install easily into the 7800 series relay module. They are available
in 15 timing ranges from 2 seconds to 30 minutes.
Compatible with selected 7800 series relay modules.
CSA, FM approved, UL recognized
ST7800A Plug-In Purge Timer Cards
Model Selection Guide
* Leadwire runs greater than 50 ft.
Color Flame Failure Self- Catalog
Code Type Response Time Checking Compatible Flame Sensors Number Price
Rectification-Type Flame Amplifiers, Green
Green Rectification 3.0 Seconds Dynamic C7024E, F Flame Detector R7824C1002 $605.36
Green Rectification 0.8 or 1.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179 R7847A1025 241.51
Green Rectification 2.0 or 3.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179; R7847A1033 241.51
Gas, Oil and Coal: Ultraviolet Flame Sensors C7012A, C
Green Rectification 0.8 or 1.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179* R7847A1074 241.51
Green Rectification 2.0 or 3.0 Second Standard Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179* R7847A1082 241.51
Gas, Oil, and Coal: Ultraviolet Flame Sensors C012A, C
Green Rectification 0.8 or 1.0 Second Ampli-Check Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179 R7847B1023 693.71
Green Rectification 2.0 or 3.0 Second Ampli-Check Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179 R7847B1031 693.71
Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012A, C
Green Rectification 0.8 or 1.0 Second Ampli-Check Gas: Rectifying Flame Rods C7004/7005/7007/7008/7009, Q179* R7847B1064 693.71
Green Rectification 2.0 or 3.0 Second Dynamic Gas, Oil, and Coal: Ultraviolet Flame Sensors C7012E, F R7847C1005 548.49
Infrared-Type Flame Signal Amplifier, Red
Red Infrared 2.0 or 3.0 Second Standard Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015 R7848A1008 453.29
Red Infrared 2.0 or 3.0 Second Ampli-Check Gas, Oil, and Coal: Infrared Lead Sulfide Flame Sensors C7015 R7848B1006 483.97
Ultraviolet-Type Flame Signal Amplifier, Purple
Purple UV 0.8 or 1.0 Second Standard Gas, Oil: Minipeeper C7027A, C7035A, C7044 R7849A1015 241.51
Purple UV 2.0 or 3.0 Second Standard Gas, Oil: Minipeeper C7027A, C7035A, C7044 R7849A1023 241.51
Purple UV 0.8 or 1.0 Second Ampli-Check Gas, Oil: Minipeeper C7027A, C7035A, C7044 R7849B1013 377.08
Purple UV 2.0 or 3.0 Second Ampli-Check Gas, Oil: Minipeeper C7027A, C7035A, C7044 R7849B1021 377.08
Ultraviolet-Type Flame Signal Amplifier, Purple
Purple UV 2.0 or 3.0 Second Dynamic Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061 R7861A1026 635.99
Purple UV 0.8 or 1.0 Second Dynamic Gas, Oil, and Coal: Ultraviolet Flame Sensor C7061 R7861A1034 635.99
FLAME
SAFEGUARD
Catalog
Description Number Price
2-Second Pre-Purge ST7800A1005 $67.88
7-Second Pre-Purge ST7800A1013 67.88
10-Second Pre-Purge ST7800A1021 67.88
Catalog
Description Number Price
30-Second Pre-Purge ST7800A1039 $67.88
60-Second Pre-Purge ST7800A1054 67.88
1.5-Minute Pre-Purge ST7800A1062 67.88
Catalog
Description Number Price
2.5-Minute Pre-Purge ST7800A1070 $67.88
4-Minute Pre-Purge ST7800A1088 67.88
6-Minute Pre-Purge ST7800A1096 67.88
Model Selection Guide
Don’t see the timer card
you need? Call Lesman.
7
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
FLAME
SAFEGUARD
S7800A1142 Universal Keyboard Display Module
Provides current status of burner sequence, timing, hold, and lockout information plus
selective or preemptive messages. Required for programming Valve Proving and Post
Purge features on 7800 series relay modules.
First-out annunciation and system diagnostics provided in 2-row by
20-column display
Provides burner control data, remote reset, and report generation
Local or remote operation, fault information
UL listed, CSA certied, FM approved, and FCC
rated
S7810A1009
Data ControlBus Module
Lets you connect a remote reset switch,
a remote keyboard display module, or
communicate to a personal computer.
Installs directly on front of 7800 relay modules
Communications interface, remote reset
Use with remote mounted keyboard display
S7820A1007
Remote Reset Module
Links a remote reset switch (push-button) that
allows the 7800 series burner control to be reset
from a remote location.
Installs directly on front of 7800 relay module
Allows reset of 7800 series relay module by a remote reset
push-button up to 1000 feet away
S7830A1005 First-Out Expanded Annunciator Panel
Monitors the status of a series string of limit, control, and interlock contacts. It enhances fault
and status messages of the 7800 series burner control.
26 LEDs — 22 LEDs to annunciate limits and interlocks, 4 LEDs to annunciate
power, current status, first-out status, and system lockout
Enhances keyboard display module sequence hold
and lockout messages
Connects to 7800 series relay module via RS485
UL listed, CSA, FM approved
Model Selection Guide
Catalog
Description Number Price
Universal Keyboard Display S7800A1142 $485.61
Model Selection Guide
Catalog
Description Number Price
First-Out Expanded Annunciator S7830A1005 $935.07
Connector for Keyboard Display 203541 45.30
Burner Control Plug-In Accessory Modules
Catalog
Description Number Price
Remote Mounting of Keyboard Display Module S7810A1009 $206.64
PC Interface, and Remote Reset Function
Model Selection Guide
Catalog
Description Number Price
Remote Module for Resetting 7800 Series S7820A1007 $228.75
Relay Module
Model Selection Guide
Hey Lesman... Wheres My Stuff?
Want to know when your Lesman order will arrive? Use the Order
Status checker, right on the Lesman.com homepage!
Enter your PO number and 5-digit zip code,
and click the “Check Status” button.
We’ll show your order details and a clickable
tracking link at UPS or FedEx. If the order
hasn’t shipped, it’ll give you the expected
ship date.
Buy your Honeywell
burner controls and
ame safeguard products
at Lesman.com for an
instant 15% savings!
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
8
V 10.2008
FLAME
DETECTORS
C7008, C7009
Rectification Flame Rods
Kantal A-1 flame rod with sparkplug-type rod holder,
threaded base, and snap-on cover.
100% fail-safe ame detection. For use with gas-red systems and
intermittent pilots only. Use with Honeywell flame safeguard controls
that require rectification-type flame detectors. Can be used with or
without cover and cut to desired length. Includes flame rod holder
and Rajah electrical connector.
Approvals: UL, CSA, FM.
Model
C7008,
C7009
Q340A
C7012
Purple Peeper®
C7027
Minipeeper®
C7035
Minipeeper®
C7061
Purple Peeper®
C7076
Detector
Type
Flame Rod Thermocouple Rectication
Ultraviolet
Ultraviolet Ultraviolet Ultraviolet Ultraviolet
Burner
Type
Gas-Fired Gas-Fired Coal, Gas, or Oil-
Fired
Coal, Gas, or Oil-
Fired
Coal, Gas, or Oil-
Fired
Gas or Oil-Fired Gas or Oil-Fired
Pilot
Type
Intermittent or
Standing
Intermittent or
Standing
Intermittent or
Interrupted
Intermittent or
Interrupted
Intermittent or
Interrupted
Intermittent or
Interrupted
Intermittent or
Interrupted
Unique
Feature
100% Fail-Safe
Operation
Low Cost Units
for Process
Applications
Dynamic
Self-Check,
Shutter
1/2” Sight Pipe
Mount
1” Sight Pipe
Mount
Dynamic
Self-Check
Dynamic
Self-Check,
Adjustable
Sensitivity
Flame
Ampli-
er
R7247A,B,
R7847A, B,
R7257, R7289
Typically
Connected
via UDC
R7247C, R7847C,
R7747C
R7249A,B,
R7849A, B,
R7749B, R7259,
R7290
R7249A,B
R7849A,B
R7749B, R7259,
R7290
R7861 R7476A1015,
R7886A1001
Flame Detectors
Model Selection Guide
Flame Rod Holder Dimensions Electrical Catalog
Length Length Diameter Connection Number Price
12” 3-3/4” 7/8” 1/4” NPT Male C7008A1174 $166.01
24” 3-3/4” 7/8” 1/4” NPT Male C7008A1182 246.46
4” 2-3/8” 3/8” 1/8” NPT Male C7009A1009 103.84
12” 2-3/8” 3/8” 1/8” NPT Male C7009A1025 135.98
Q340 Thermocouples for Gas-Fired Pilot Flame Detection
Premium long-life, durable 30mv thermocouples generate a thermoelectric current that
senses a pilot flame on gas-fired heating systems.
For easy installation, the Q340A comes with a push-in clip, split nut, and an adapter assembly, plus a 11/32 male
connector nut for Pilotstat® safety control power units.
Output: Normal: 26 to 32 mV; Lowest Acceptable: 18 mV; Turndown: 2 mV
Temperature Rating: 1400°F at hot junction, 780°F at cold junction
Replacement for: Robertshaw 1980, T45, T46, White Rogers HO series, Penn-Baso K15, K16,
K19, 88D, ITT-General 2500 and 2600 series, and Jade TK5
Catalog
Lead Length Number Price
36” (914mm) Q340A1090 10.72
48” (1219mm) Q340A1108 11.92
Model Selection Guide
C7076 UV Detector with Adjustable Sensitivity
Dual adjustable sensitivity with 400:1 dynamic range, for
use with intermittent or interrupted pilots on gas- or oil-fired
burners. Compatible with R7476A and R7886A dynamic self-
check UV flame amplifiers. Closed-loop self-checking circuit
ensures integrity of both amplifier and flame detector.
Visit www.lesman.com
for popular models.
Buy online through our
secure online store!
9
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
C7027 Minipeeper® Ultraviolet Flame Detectors
Compact UV flame detectors for use on coal-, gas-, oil-fired or combination burners. Can be
used with either intermittent or interrupted pilots. Compatible with R7248A/B, R7849A/B,
R7749B, R7259, and R7290 solid-state UV flame amplifiers on Honeywell RM7800 series relay
modules and controls.
Compact size allows for blast-tube mounting. Seals
against pressures up to 5 psi when correctly installed.
Wire in parallel for difficult sighting applications.
Mounting: 1/2” sight pipe with integral collar or 1/2”
NPT threaded spud connector.
Dimensions: 1-1/8” diameter (with mounting nut),
3-7/8” length, 8-foot lead.
Electrical Connections: Two NEC Class 1 leadwires
Approvals: UL, CSA, FM.
C7012 Purple Peeper® Solid-State UV Flame Detectors
Solid-state UV flame detector with dynamic self-check, for coal-, gas-, or oil-fired burners. Can
be used with intermittent or interrupted pilots. Compatible with R7247C, R7847C, and R7747C
UV flame amplifiers on Honeywell RM7800 series relay modules.
Mounts horizontally, vertically, or at any angle in between.
Provides quick electrical hookup with threaded conduit fitting
and color-coded leadwires. Reduces nuisance shutdowns by
wiring two in parallel.
Mounting: Mounting flange with NPT internal threads for
attaching to sight pipe
Approvals: UL, CSA, FM.
C7035
129464M
Ambient Sight Pipe Catalog
Temp. Range Mounting Number Price
-40° to 215°F Integral nut C7027A1031 $166.75
-40° to 215°F Integral nut* C7027A1072 166.75
0° to 215°F Integral nut C7027A1023 150.41
0° to 215°F Integral nut* C7027A1049 150.41
0° to 215°F Integral nut** C7027A1080 186.95
Model Selection Guide
* 1/2” NPT threaded spud connector
** Includes 136733 heat block and 390427B bushing
FLAME
DETECTORS
Model Selection Guide
Catalog
Description Number Price
Dynamic Self-Checking Ultraviolet Detector
120 VAC, 3/4” NPT C7012E1104 $3161.29
120 VAC, 1” NPT C7012E1112 3161.29
C7035 Minipeeper® Ultraviolet Flame Detectors
Compact ultraviolet flame detectors with field-replaceable UV sensing tubes. For use on coal-,
gas-, oil-fired or combination burners. Can be used with either intermittent or interrupted
pilots. Compatible with R7248A/B, R7849A/B, R7749B, R7259, and R7290 solid-state UV flame
amplifiers on Honeywell RM7800 series relay modules and controls.
Shield protects sensing tube. Seals against pressures up to 5 psi when correctly installed. Can be wired in
parallel for difficult sighting applications.
Mounting: 1” sight pipe with integral collar
Dimensions: 1-1/2” diam. (with collar), 4-1/8”
length, 72” leads
Approvals: UL, CSA, FM.
Catalog
Description Number Price
0° to 215°F temperature range, 6’ lead C7035A1023 $330.90
Replacement UV sensing tube for C7035 129464M 301.68
Model Selection Guide
129464N
C7061 Purple Peeper® Solid-State UV Flame Detectors
Ultraviolet flame detector with dynamic self-check for gas-, or oil-fired burners. Can be used
with intermittent or interrupted pilots. Compatible with R7861
dynamic self-check UV flame amplifiers on Honeywell RM7800
series relay modules.
Mounts horizontally, vertically, or at any angle in between.
Reduces nuisance shutdowns by wiring two in parallel. Field-
replaceable UV sensing tube and quartz viewing window.
Mounting: Mounting flange with 3/4” NPT internal threads
Dimensions: 5-1/4” diam. (with flange), 7-7/32” long, 96” leads
Approvals: UL, CSA, FM.
Model Selection Guide
Catalog
Description Number Price
120 VAC, 3/4” NPT C7061A1012 $1377.66
120 VAC, 3/4” NPT* C7061A1038 1398.48
UV Sensing Tube 129464N 335.68
* With Brad Harrison 41310 connector
Available soon! UV/IR ame detectors from
IRIS Systems. Call Lesman for details.
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
10
V 10.2008
FUEL AIR RATIO
CONTROL
ControLinks™ Fuel Air Ratio Control System
Stand-alone parallel positioning control system
designed for easy retrofit
Dynamic safety checks: failsafe potentiometer
check, anti-swap of actuators, and curve verifica-
tion algorithms, relay test for limit control input/
output (LCI-LCO) contact set
Integrated shock protection algorithms: Water or
stack temperature low fire hold, flue gas recircula-
tion (FGR) hold, FGR and low-fire hold
Controller LEDs: Power, alarm, motor 1, 2, 3, 4 for
status, and fault code annunciation (60 possible)
Two independent fuel proles with or without FGR
Programmable positioning for non-selected fuel
actuator, standby, purge, light-off, or minimum/
maximum modulation
Up to four universal parallel positioning actuators:
Combustion air, fuel 1, fuel 2, FGR/flexible usage
Fourth channel actuator exible usage: FR, second-
ary air control, secondary modulating fuel valve
Auto/manual ring rate input
Seven to 24 points per prole curve with quick
setup feature, providing minimum three-point
profile curve
Actuator CW/CCW switches for manually driving
hub —useful for installation and service
Actuator LED annunciation for uncongured, con-
figured, on-line, or faulty actuator states
Honeywell ControLinks™ replaces the traditional single point modulation of a
mechanical cam-and-linkage assembly that controls the relationship between fuel,
airflow, and flue gas recirculation on a power burner. The linkageless fuel air ratio
control provides more accuracy and efficiency in actuator positioning and burner
firing, reducing your service requirements and downtime. It can be installed as part of
a retrot or a new burner application —anywhere increased efciency is desired.
Up to four independently controlled universal parallel positioning actuators
(UPPAs) are managed by the ControLinks controller, which responds to load and
firing rate demands.
ControLinks can be used on single or combination fuel single burner applications,
including power burners, boilers, process furnaces, ovens, smelting, kilns, paint drying
booths, VOC burn-off, ceramics, make-up air heaters, or any full modulating burner.
Honeywell ControLinks™ fuel air ratio control system helps you realize energy savings, increased turndown, reduced
emissions, and system reliability in an easy-to-install, powerful, and cost-effective package.
Features
R7999A ControLinks™ Fuel Air Controller
Uses the latest microprocessor technology to simultaneously control up to four actuators.
Use with ML7999 actuators to replace mechanical cam-and-linkage assembly controlling
the relationship between fuel, airflow, and flue gas recirculation (FGR) on a power burner.
Fast burner setup vial PC or laptop. Two independent fuel profiles with or without FGR. Programmable
behaviors of all actuators during purge and standby. Programmable behavior of non-selected fuel actuator.
Independent light off and minimum modulation positions. Auto/manual input and manual mode firing-rate
input. Multipurpose communications port.
ZM7999A ControLinks™ configuration software tool lets you create burner modulation curves (profiles)
for your burners, for safe and efficient operation at all points along the curve. Wizards step you through the
commissioning process. Save files on your PC to use over again.
Complete System Requires: R7999 controller, Q7999 wiring subbase, ML7999 positioning actuator,
and ZM7999 configuration software.
Model Selection Guide
Catalog
Description Number Price
Fuel air ratio controller, 100-120 VAC, 50/60 Hz R7999A1005 $774.90
Field wiring terminal subbase for R7999A controller. Panel mount, NEMA 1 enclosure Q7999A1006 98.53
ControLinks™ Windows-based configuration software for R7999A controllers ZM7999A1006 365.93
Typical boiler application with Honeywell ControLinks™
fuel ratio control system installed.
11
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
FUEL AIR RATIO
CONTROL
ML7999 Universal Parallel-Positioning Actuators
ControLinks™ actuators control the position of primary and secondary fuel valves,
combustion air damper, and flue gas return dampers. UL, CSA, CE approved.
Vibration: 0.0 to 0.5g continuous
Environmental Conditions: Ambient Temperature: -40° to 140°F; Operating Tem-
perature: -40° to 150°F; Operating Humidity: 5% to 95% RH, non-condensing
Model Selection Guide
Catalog
Actuator Description and Function Number Price
Pulse-width modulating control of combustion air dampers, butterfly gas valves, oil ML7999A2001 $272.80
modulation valves, and flue gas recirculation systems. Includes precise feedback
potentiometer and integral power supply. Parallel-positioning actuator.
Provides 4-20 mA control input to control combustion air dampers and modulation ML7999B1002 540.84
valves. Includes precision drive shaft control and integral power supply capable of
direct line voltage connection. Direct coupled actuator.
Call for adapter assemblies for
connecting to shaft sizes other
than 1/2”.
S7999B ControLinks™ Configuration Display
Monitor up to 99 burner systems connected via Modbus. Each burner control,
fuel/air ratio control, expanded annunciator or other Modbus devices present
on the burner system can be viewed individually to determine its status.
Display: Color 3.5” x 4.6” touchscreen interface with screen saver, contrast and volume controls
Communications: Two RS485 Modbus ports for monitoring up to 99 unique controls
Function: Allows setup and monitoring of R7999 ControLinks controller, programmable
expanded annunciator terminal remaining, and R7999 EEPROM backup and restore
Model Selection Guide
Catalog
Description Number Price
Touchscreen display for ControLinks™ system. 12 VDC input power S7999B1000 $1193.07
Model Selection Guide
Catalog
Description Number Price
ML7999 actuator shaft adapter for and 3/8” round or square valve shaft 201391 $3.23
ML7999 actuator weatherproofing kit (1 corner stop, 2 gaskets) 32002935-001 18.56
ML7999 actuator 3/4” shaft adapter assembly 32003168-001 44.22
ML7999 actuator 5/8” shaft adapter assembly 32003168-002 50.07
ML7999 actuator 9/16 shaft adapter assembly 32003168-003 50.07
V51E mounting plate for 1.5” and 2” valves 32003396-001 43.48
V51E mounting plate for 2.5” 3”, and 4” valves 32003396-002 47.34
R7999 3-pin electrical connector 32002515-001 9.53
ControLinks™
Accessories
Looking for a
portable combustion
analyzer?
See page 29.
Handhelds available
for sale or rent!
Learn more online at
www.lesman.com!
P7810C Pressuretrol® Controller
Line voltage pressure controller that eliminates the need for a controller and transmitter.
One unit does on/off control, high limit and 4-20 mA modulation.
Accuracy: ±4.0% full scale output over operating temperature (32° to 140°F)
Model Selection Guide
Catalog
Description Number Price
Solid State Pressuretrol® Controller with On/Off Control, Limit Control, 0–15 PSI P7810C1000 $524.81
and 4-20 mA Modulation. FM, CSA, UL Approvals. 0–150 PSI P7810C1018 583.72
LED Indicators for Power, Call for Heat Function, and Lockout Status 0–300 PSI P7810C1026 651.85
Siphon Loop with 1/4” NPT Threads for P7810C 209731A 32.61
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
12
V 10.2008
Mechanical Burner Controls and Safety Switches
BURNER
CONTROLS
C6097 Safety Limit Switches
Limit switches for positive or differential pressure systems to sense natural gas, liquid
propane gas, or air. Removable clear protects scaleplate and adjusting knob.
Temperature Range: -40° to 140°F
Switch Ratings: 3.0 AFL, 18.0 ALR, 5.0 Amp resistive. Can be wired to turn on alarms.
Model Selection Guide
Operating Pressure Differential at Switch Catalog
Range Min. Setpoint Max. Setpoint Operation Mounting Number Price
Diaphragm-Actuated Safety Limit Switch, Brake on Pressure Fall, 1/8” NPT Internal Threaded Connection
0.4” to 5” WC 0.6” WC 0.25” WC Manual Reset 1/4” NPT C6097A1095 $117.40
3” to 21” WC Auto Recycle 1/4” NPT C6097A1053 96.26
Diaphragm-Actuated Safety Limit Switch, Break on Pressure Rise, 1/8” NPT Internal Threaded Connection
12” to 60 “ WC 10” WC 12” WC Manual Reset 1/4” NPT C6097B1002 124.96
1.5 to 7 PSI 1.1” WC 1.4” WC Manual Reset 1/4” NPT C6097B1051 136.22
L404F Pressuretrol® Controllers
Operating control with automatic limit protection for pressure systems. Use with steam, air,
noncombustible gases, or fluids non-corrosive to pressure sensing element
Switching Action: SPDT snap-action switch to open or close a circuit on pressure rise
Connections: Pipe (main or high pressure): 1/4” NPT internal thread; Electrical: Screw terminals
Model Selection Guide
Operating Sustained Adjustable Sensor Unit Catalog
Range Pressure Differential Element Includes Number Price
2 to 15 PSI 25 PSI max. 2 to 6 PSI Stainless Steel Diaphragm Siphon Loop L404F1060 $172.29
5 to 50 PSI 85 PSI max. 6 to 14 PSI Stainless Steel Diaphragm Ground Screw L404F1375 175.01
10 to 150 PSI 225 PSI max. 10 to 22 PSI Stainless Steel Diaphragm L404F1102 192.05
Use with flame rods, rectifying photocells and C7012A,C Purple
Peeper ultraviolet flame detectors. Recycles once after failure to re-
establish pilot. No start if failure occurs in flame detector circuit.
Power Rating: 50 Hz: 8.5w, 17VA max.; 60 Hz: 7w, 13 VA max.
Ambient Temperature: -20º to 105°F
Approvals: CSA, FM, UL
Model Selection Guide
Safety Switch Flame Failure Catalog Price
Description Timing Response* Number Each
Rectification-Type 15 Seconds 3.0 Seconds RA890F1288 $1385.97
Ultraviolet-Type 15 Seconds 3.0 Seconds RA890G1260 1385.94
Q270A Protectorelay® Mounting Subbase Q270A1024 116.04
Compatible flame detectors on pages 8–9.
S8610U3009 Intermittent Pilot Ignition Control
Provides ignition sequence, flame monitoring, and safety shutoff for intermittent pilot
ignition systems used on natural or LP gas-fired furnaces, boilers, and heating applications.
Electrical Rating: 24 V, 60 Hz; Current Draw: 1A
pilot valve, 2A main valve; Contact Rating: 0.2A
Field Replacement: For most Honeywell,
Robertshaw, Johnson, UTEC (HCS)
intermittent pilot ignition modules
Model Selection Guide
Catalog
Description Number Price
Intermittent pilot control. 15- or
90-sec trial for ignition, 0- or S8610U3009 $164.37
30-sec configurable pre-purge
RA890 Protectorela
Electromechanical Primary Control
Non-programming primary control provides flame safeguard
protection for industrial and commercial single or dual fuel
burners. With SPDT alarm contacts.
13
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
Modutrol IV
Low torque, light duty, rotary action Modutrol IV motor is designed for accurate positioning
of dampers and valves in industrial ovens, furnaces, and process heaters.
Torque Rating: 25 to 300 Lb-In
Timing: 15 to 240 seconds
Stroke: Fixed or adjustable, 90° and 160° dual on some models
Limit Switches: Two end-of-travel limit switches standard
Approvals: CSA, UL
More models available online. Visit www.lesman.com/get/modutrol.php for series
specifications, model selection, and part number cross references.
Model Selection Guide
ACTUATOR
CONTROLS
Low-Torque Rotary Actuator Motors
* Field-addable auxiliary switches
Stroke Timing Torque Auxiliary Functional Replacement Catalog
90° 160° Rating Switches Product Includes for These Obsolete Models Number Price
Proportional-Reversing Motors, 135 Ohm Input Signal, 90° to 160° Field-Adjustable Stroke (Unless otherwise specified)
15 sec 30 sec 75 Lb-in 0 M9184D1005 $806.09
15 sec 30 sec 75 Lb-in 1 Tapped Shaft M9484D1002, D1036, and E1116 M9484E1009 965.43
30 sec 60 sec 35 Lb-in 0 Adjustable Zero/ Span, Transformer M8161A1024 and A1032, M9164A1005 682.92
M9161A1008, M9164A1021 and A1054
30 sec 60 sec 35 Lb-in 0* M9164A1120, A1062, A1047, and A1096 M9164D1009 608.10
30 sec 60 sec 60 Lb-in 0* 24 VAC, Spring Return M7285A1052, M7282A1006, M9185D1004 905.25
M9175D1014, D1006, and D1014
30 sec 60 sec 60 Lb-in 1 M9185E1019 1013.40
30 sec 60 sec 150 Lb-in 0 M9484D1028, D1044, and D1051 M9484D1010 822.55
30 sec 60 sec 150 Lb-in 0* M9184A1012, A1035, B1009, B1017, B1025, M9184D1021 836.50
M9184D1013, D1047, and D4009
30 sec 60 sec 150 Lb-in 1 M9484E1090 and E4003 M9484E1017 965.43
30 sec 60 sec 150 Lb-in 1 Motor Crank Arm, M9484E1025, E1041, E1058, E1066, M9484E1033 954.42
Ships in 90° Position M9484E1074, and E1082
30 sec 60 sec 150 Lb-in 2 Ships in 90° Position M9484F1007 1014.01
30 sec 60 sec 150 Lb-in 2 Tapped Shaft, Ships in 90° Position M9484F1031 1024.93
30 sec 60 sec 150 Lb-in 2 M9184F1000 and F1018 M9184F1034 1008.54
30 sec 35 Lb-in 2 M9184C1031 1008.54
60 sec 60 Lb-in 2 24 VAC, Spring Return M9185C1006 1094.20
60 sec 150 Lb-in 0 M9181A1012, M9184A1001 M9184A1019 806.09
Proportional-Reversing Motors, 120 VAC Power, Modulating 4-20 mA Input, Adjustable Zero and Span. Transformer and Screw Terminal Adapter Included
15 sec 30 sec 75 Lb-in 0 M7284A1038 984.96
30 sec 60 sec 150 Lb-in 0 M281A1007, M7284A1046 M7284A1004 940.89
30 sec 60 sec 150 Lb-in 0 M7284A1020 M7284A1012 940.89
30 sec 60 sec 150 Lb-in 2 M7284C1018, M7284C1026 M7284C1000 1103.17
30 sec 60 sec 150 Lb-in 2 M7284Q1017 M7284Q1009 1103.17
60 sec 120 sec 300 Lb-in 2 M7294Q1007 1106.72
Motors with Switched SPDT or Floating Output, 120 VAC Power, SPDT Input, 3-Wire, Line Voltage, or Position Proportional Controller
30 sec 75 Lb-in 0 M6184A1023 606.46
30 sec 150 Lb-in 0 M6284A1014, A1002, A1048, A1071, and 1063 M6284A1055 733.15
Motors with Switched SPDT or Floating Output, 24 VAC Power, 3-Wire, SPDT or Voltage Input
15 sec 30 sec 75 Lb-in 0 Low Voltage M6184D1001 554.23
30 sec 60 sec 150 Lb-in 0* Low Voltage M6181A1018, D1004, F1009, F1017, M6184D1035 544.29
M6161A1004, M6184A1007 and B1021
30 sec 60 sec 150 Lb-in 2 Line Voltage M6184F1014 714.91
Stroke Stroke Torque Auxiliary Functional Replacement Catalog
Timing (Deg) Rating Switches Product Includes for These Obsolete Models Number Price
Two-Position Spring Return Motors, SPST, 2-Wire, Voltage Inputs
30 sec 75° 20 Lb-in 1 120 VAC Power M436A1041 A1082, A1090, A1165, and A1181 M436A1116 $350.76
60 sec 160° 60 Lb-in 0 120 VAC Power M4185A1001 554.32
60 sec 160° 60 Lb-in 1 120 VAC Power M4182B1002 M4185B1009 587.40
30 sec 90° 60 Lb-in 1 120/208/240 VAC M4185B1017 M4185B1058 610.07
20 sec 45° 30 Oz-In 0 M847A1072 123.66
30/60 90/160 60 Lb-in 0* 24 VAC M8185B1000 and B1034 (w/ 220736A) M8185D1006 456.87
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
14
V 10.2008
Use with Honeywell V5055 gas valves where smooth light off is important to control gas
supply to industrial burners.
One second maximum closing time. Con-
tinuous display of valve position with a red
(open) or yellow (closed) indicator. Provides
final safety shutoff service when used with
V5055 valves.
Temperature Range: -40° to 150°F
Operating Pressure: 5 psi maximum
Electrical Rating: 120 VAC, 60 Hz
Auxiliary Switch Contact Ratings: 9.8 AFL,
55.8 ALR, 1/2 hp;
Proof of Closure Switch Contact Ratings
(V4055D): 4.9 AFL, 29.4 ALR, 1/2 hp; 9.8 AFL,
58.8 ALR, 1/2 hp
V4055 On-Off Gas Valve Actuator
Model Selection Guide
Timing Internal Damper Catalog
(Open) Auxiliary Switch Shaft Number Price
On-Off Actuator, Use with V5055/V5097A,B Valve Bodies
13 sec Yes (90° Stroke) No V4055A1296 $559.16
13 sec No Yes V4055A1098 499.13
13 sec No No V4055A1031 499.13
26 sec No Yes V4055A1064 462.11
26 sec No No V4055A1007 462.11
26 sec No No V4055A1312* 976.96
On-Off Actuator with Proof of Closure Switch, Use with V5055C/
V5097C Valve Bodies
13 sec Yes No V4055D1035 600.71
13 sec No Yes V4055D1019 540.65
13 sec No No V4055D1043 540.65
26 sec No Yes V4055D1001 505.95
* NEMA 4 Enclosure
VALVES AND
ACTUATORS
V5055 Industrial Gas Safety Shutoff Valve
V51E Butterfly Firing Rate Gas Valve
Valves and Actuators
Provides modulating control of natural, manufactured, LP gases or air.
Use in commercial and industrial instal-
lations where large amounts of gas must
be closely controlled. Do not use as a safety
shutoff valve. Use with mod motor and
Q100 linkage. Includes strain release.
Temperature Range: 32° to 140°F
Pressure: Rating: 5 psi max.; Inlet/outlet
pressure tapping: Two downstream 1/4”
NPT taps
Material: Aluminum body
Approvals: UL
Model Selection Guide
Pipe Catalog
Size Capacity Number Price
1.5” 4200 cf/Hr – 118.9 m3/Hr V51E1000 $396.95
2” 9210 cf/Hr – 260.7 m3/Hr V51E1018 448.72
2.5” 8390 cf/Hr – 199.8 m3/Hr V51E1034 474.85
3” 14640 cf/Hr – 414.5 m3/Hr V51E1059 500.35
Bracket for 2” valve/Modutrol motor 127413 169.18
Bracket for 2.5” valve/Modutrol motor 127415 203.18
Strain release assembly 49085B 214.28
Stop screws for stop bracket (2 reqd.) 80897BC/0021 2.93
Linkage kit V51 to M941 Modutrol Q100B1006 99.81
Looking for a
mod motor?
See page 13.
Safety shutoff valves used with V4055 fluid power actuators to control natural or LP gas
flow to commercial and industrial burners. Mounts directly in gas supply line.
Temperature Range: -40°F to 150°F
Includes: 1/4”–18 NPT upstream and downstream taps and plugs
Proof of Closure: V5055C valves have double seal and are used with V4055D and V4055E actuators to provide
proof-of-closure switch and valve seal over-travel interlock
Approvals: FM, CSA, and UL
Model Selection Guide
* When used with V4055A or D models. 15 PSI when used with V4055B, E, F, or G models.
Pipe Max Operating Catalog
Size Capacity Differential* Functions Number Price
Safety shutoff valves for use with V4055 valve actuators
1.5” NPT 1717 cf/Hr – 48.6 m3/Hr 5 PSI max On/off safety shutoff V5055A1020 $301.74
2” NPT 3620 cf/Hr – 102.5 m3/Hr 5 PSI max On/off safety shutoff V5055C1000 731.15
with double seal
2.5” NPT 4250 cf/Hr – 120 m3/Hr 5 PSI max On/off safety shutoff V5055C1018 861.65
with double seal
3” NPT 4250 cf/Hr – 148 m3/Hr 5 PSI max On/off safety shutoff V5055A1053 674.84
15
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
COMBUSTION
CONTROLS
MAXON Combustion Control Systems
Precise electronic control of air and fuel ow to the burner to maxi-
mize efficiency and minimize emissions simultaneously
Maintains emissions or fuel efciency over the entire operating range
of the burner, not just at one burner setpoint
Automatically compensates for changes in combustion or process
conditions with full cross-limited ratio control, maximizing burner
performance and ensuring a highly repeatable heat source
Integrates easily with all burner management systems, reducing
engineering costs in retrofit applications
Advanced diagnostics and troubleshooting provide real-time infor-
mation about combustion and process system performance
Remote monitoring gateway option reduces process downtime by
providing immediate off-site technical support over a phone line
Redundant system safety checks built into intelligent components
significantly reduces the risks associated with combustion system
commissioning and maintenance neglect
FM and CSA approved, and meets requirements
of European EMC and low-voltage directives
SMARTFIRE® Intelligent Combustion Control System
Safety Shutoff Valves
Cast iron, carbon steel, low-temp carbon steel,
and stainless steel bodies with internal trim op-
tions for general purpose or corrosive gases
Unique bonnet design eliminates packing
adjustments, reducing maintenance and
minimizing drag on closing
Oxygen compatibility available
Meet Fluid Control Institute 70-2 control valve
standard for Class VI seat leakage; Full assess-
ment to IEC 61508 as SIL-3 capable
Series 5000 Electromechanical Valves
Electrically actuated valves
with powerful closing spring,
provides closure in <1 second
for reliable operation
3/4” to 6” line sizes, pressures
to 125 psig
Field-rotatable top assemblies
in 90° increments to fit your application
Actuators available with manual reset or
automatic reset operators
Ambient, gas temperatures: -20° to 140°F
Available normally closed or normally open
FM, CSA, UL, and CE approved; Available for
non-incendive Class I, Div 2 areas
Series 8000 Air-Actuated Valves
Pneumatically actuated
valves with powerful
closing spring for reliable
operation
3/4” to 6” line sizes, pressures
to 255 psig
Compact design with inte-
gral solenoid, quick exhaust
and position switches that
protects components, sim-
plifies piping, and minimizes space needs
Temperature ranges: Ambient: -40° to 140°F;
Gas: -40° to 212°F
FM, CSA, and CE approved safety shutoff and
vent valves; Available in intrinsically safe and
non-incendive constructions for hazardous
location use
NACE-compliant trims available
MICRO-RATIO® Flow Control Valves
These assemblies are used for air, gas,
and oil proportioning control. The multiple
screw cam assembly provides mechanical
adjustment capabilities to the air/fuel ratio
at each valve position throughout the entire
capacity range of your burner system.
Throttling range is fully adjustable and
designed to operate over the wide turndown
capabilities of Maxons burner systems.
Stand-by fuel requirements are simplified
by using tandem-linked air-gas-oil” valves
to provide single point control for multiple
fuel or multiple zone systems.
A complete system using Maxon flow
control valves will typically include a burner,
gas and/or oil pipe trains, mixing equipment,
pressure blower, and a control panel.
Look for more information
on Maxon combustion control
systems, burners, and valve
products online at Lesman.com
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
16
V 10.2008
INDUSTRIAL
BURNERS
Burner Systems for Industrial Applications
Finding the right Maxon burner
for your application
AP
NP-LE AIRFL
CROSSFIRE®
TUBE-O-FLAME®
TUBE-O-THERM®
OVENPAK® LE
M-PAKT®
KINEMAX®
OVENPAK® 400
MEGAFIRE®
KINEDIZER® LE
OPTIMA™ SLS
UNI-RAD®
Heat Treating and Furnace Burners √ √
Low Emissions √ √ √ √
Make-Up Air (Food or Spray Dryers, Food Processing) √ √
Oven Burners √ √
Oxidizers √ √
Paper Mill Dryers √ √ √ √ √ √
Pre-Heated Combustion Air √ √ √
Rotary Dryers and Kilns √√√
Solution Heating and Finishing Systems √ √√√√
Steel Mills √ √
APX®
Nozzle-mixing line burner for use
with low pressure natural gas,
propane and butane
Single-piece aluminum extrusion
body design eliminates leakage
Cooler oven walls due to deeper penetration inside the oven (wall-
mount); Independent of variable process air flows (in-duct)
Corrosion-resistant main gas/air body and durable stainless steel
mixing plates
Up to 1.0 MMBtu/h per foot; Up to 40:1 turndown
Packaged units up to 15 foot in length
CROSSFIRE®
Nozzle-mixing line burner for
use with low pressure natural
gas firing
Extremely low emissions
Capable of NOx levels of 25ppm and CO levels of 250ppm at 3% O2
Temperature uniformity to enhance product quality
Also available in stainless steel housings or nickel-plated body
Up to 2.5 MMBtu/h per foot; Up to 25:1 turndown
NP-LE AIRFL
Designed for direct-red make-up
air and process applications
Improved emissions over Maxon’s
earlier NP AIRFLO units, with significantly
lower CO and NO2 levels
Shorter ame length
Available in low pressure version and corrosion-resistant materials
Easily meets ANSI/CSA standards
Up to 1 MMBtu/h per foot; Up to 30:1 turndown
TUBE-O-FLAME®
Nozzle-mixing refractory-less burners for
tube firing
Burns any clean low-pressure fuel gas
Increases heat transfer efciencies with
long swirling flame pattern
Flange-mounted compact design
for easy installation
Low horsepower requirements
reduce initial and operating costs
Produces low levels of NOx in combustion products
Generates less noise than open-port tube ring
Capacities to 5 MMBtu/h; Up to 20:1 turndown
TUBE-O-THERM®
Burns natural gas, propane, or butane
Burner-to-tube direct ring system allows
uniform heat transfer, eliminates hot
spots, and produces faster bring-up
times
Fires directly into small-bore im-
mersion tubes
Designed with integral low-horse-
power blower to lower costs and
save energy
Wall- or tube-mount design for no-hassle installation and easy main-
tenance access
UV ame scanner capability for all four sizes
Capacities to 5.3 MMBtu/h
Look for more information on Maxon
combustion control systems, burners,
and valve products online at Lesman.com
17
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
M-PAKT®
Burns natural gas or propane
Extremely low emissions Capable of single-digit
NOx and CO levels at 3% O2
Flame contained almost entirely inside the dis-
charge sleeve
Durable steel outer construction
with stainless steel internals
Compact design with a variety of
control methods
Up to 8.4 MMBtu/h; Up to 13.5:1 turndown
OVENPAK® LE
Burns any clean fuel gas, and operates
on low gas supply pressures
Provides clean combustion with low
NOx and CO levels
Compact burner design provides
quick and easy installation
Balanced pressure design and visible
ignition action for easy commissioning,
adjustment and maintenance
Up to 6.5 MMBtu/h; Up to 100:1 turndown
KINEMAX®
Burns most clean low-pressure gaseous
fuels or light oil; Can be used with
oxygen-enriched combustion air
Lower fuel consumption using
preheated combustion air (up to 800°F)
Operate on-ratio with excess fuel or ex-
cess oil to meet specific demands of your
combustion process
Exit velocities up to 275 ft/s to promote workload heat penetration
and better furnace temperature uniformity
Refractory block for chamber temperatures up to 3000°F
Removable backplate gives easy access for inspection, maintenance
Seven sizes, capacities to 8.4 MMBtu/h; Up to 48:1 turndown
KINEDIZER® LE
Burns natural gas, propane, or
other fuel gases
Accepts preheated and vitiated
combustion air
Field-proven low emissions; State-
of-the-art NOx firing, adjustable
for application flexibility
Rugged design for oxidizers, process heaters, kilns, furnaces, dryers,
waste incineration, and other high-temperature applications
Excellent stirring and mixing with medium velocity exhaust
Six sizes, capacities up to 75 MMBtu/h; Up to 22:1 turndown, with the
lowest NOx and excess air in the KINEDIZER® family!
OPTIMA™ SLS
Fuel exible with natural gas, pro-
pane, and butane capability
Low NOx and CO production levels
for extremely clean, reliable heat
— and easy air permitting and
environmental compliance
Large capacity heat releases with a
compact, robust flame geometry
Intelligent ratio control provides reliable operation and optimal fuel
efficiency
All steel and high temperature alloy construction for reduced weight,
increased durability
Congurable for dryers, air heaters, ovens, kilns, process heaters, paper
machines, and a variety of industrial heating equipment
Direct factory operational support with SMARTFIRE® control and
communication gateway
Five sizes, capacities to 93.5 MMBtu/h; Up to 17.8:1 turndown
UNI-RAD®
Radiant tube burner for fuel gas inputs
Suitable for use on pressure tubes,
negative pressure tubes, and electri-
fied radiant tubes
Flame length adjustable by changing
combustion air-to-ignition ratios
produces optimum tube temperature uniformity over a wide range
of firing rates and preheated air temperatures
Continuous plasma spark provides instantaneous ignition, so burner
can operate from the DAT output of a PID control loop
Can be used in conjunction with UV ame supervision equipment
OVENPAK® 400
Burns any clean fuel gas; Requires
only low-pressure gas
Fires into passing air streams
Provides clean combustion with low NOx
levels
Simple eld adjustment and maintenance
Compact burner design provides quick
and easy installation
More than 90 different styles and sizes
— including cost-effective external blower versions
Capacities to 16.5 MMBtu/h; Greater than 40:1 turndown
MEGAFIRE®
Provides clean burning of #2 oil,
natural gas or propane; Fires gas,
oil, or both simultaneously
Inline blower version includes
energy-efficient centaxial direct
drive combustion air blower
Quiet operation with exceptionally
low horsepower requirement
Nine different styles, three different sizes
Capacities to 45 MMBtu/h; 10:1 turndown on #2 oil, 15:1 turndown
on natural gas
INDUSTRIAL
BURNERS
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
18
V 10.2008
MicroM Flame Safeguard Burner Control System
MicroM Flame Safeguard controls
are compact, modular burn manage-
ment systems designed to provide automatic ignition and continuous
flame monitoring for commercial-sized heating and process burners
firing any type of fuel.
The MicroM incorporates remote reset capability and serial
communications via MODBUS. The optional ED510 display can be
used to access burner hours and cycles, system hours, the last 6
lockouts with burner cycle time stamp and programmer configu-
ration. MODBUS communications capability allows the integration
of the MicroM control into upper level energy management/data
acquisition systems.
A complete MicroM system consists of the appropriate flame
scanner/detector, plug-in amplifier, and programmer modules con-
nected to a chassis and wiring base. Interchangeable programmer
and amplifier modules allow versatility in selecting control function,
timing, and flame scanning method.
All amplifiers are available with flame failure response times of
0.8 or 3 seconds nominal (4 seconds max), and each provide a set
of test jacks with a range of 0-10VDC for the measurement of flame
signal intensity.
Smart LED indicators on all programmer modules indicate the
current operating status of the control, and during a safety lockout,
display the fault as a coded sequence, simplifying troubleshooting
during a shutdown. A run-check switch is provided on the MEP500
series programmers to assist in testing size, position, and stability of
the pilot. A safety checking circuit runs on each start. If flame (real
or simulated) is detected prior to a start or during purge, the fuel
valves will not be energized and the control will lock out.
MicroM Subbase Mounting Adapters
The MicroM can fit directly onto your existing Honeywell Flame Safeguard
mounting subbase with the addition of a single mounting adapter. No need to
do any rewiring or expensive re-engineering for retrofits.
Model Selection Guide
Catalog
Description Number Price
MM-2 Mounting Adapter to Retrofit to R4795 Systems 60-1765 $96.60
BURNER
CONTROLS
Model Selection Guide
*MicroM chassis model MEC120RC includes all these options.
Catalog Avail-
Component Description Number ability Price
120VAC Input , Standard Board MEC120 $339.00
Chassis 120 VAC Input with Remote Reset
Capability, Interface to Alphanu-
meric Display, Communications,
Modbus Capability MEC120RC 493.00
Programmer Relight Operation, 10 Sec. PTFI MEP100 151.00
Selectable Purge Timing, PTFI
Timing, Recycle/Non-Recycle,
Post Purge, Prove Air Open at Start MEP230 365.00
Selectable Purge Timing to 60 Min. MEP536 458.00
Non Self-Checking Scanner, 3 Ft.
Flexible Cable, 1/2” NPT Connector UV1A3 160.00
Non Self-Checking Scanner, 6 Ft.
Flexible Cable, 1/2" NPT Connector UV1A6 189.00
Flame Infrared Scanner, 8 Ft Shielded
Scanners Cable with 90° Head 48PT2-9003 252.00
(See pg 20 Ultraviolet Self-Checking Scanner,
for details) 120 VAC Shutter, 1" NPT Threads 45UV5-1009 1373.00
Flame Rod for Gas Flames, 12"
Length, 1/2" NPT Connection 69ND1-1000K4 106.00
UV Amplifier, 0.8 Sec Flame Failure
Response Rate (FFRT) MEUV1 74.30
UV Amplier, 3 Sec FFRT MEUV4 74.30
Infrared Amplier, 0.8 Sec FFRT MEIR1 149.00
Amplier Infrared Amplier, 3 Sec FFRT MEIR4 149.00
Modules UV Self-Check Amplier, 0.8 Sec FFRT MEUVS1 160.00
UV Self-Check Amplier, 3 Sec FFRT MEUVS4 160.00
Flame Rod/Photocell Amplifier,
0.8 Sec FFRT MERT1 74.30
Flame Rod/Photocell Amplifier,
3 Sec FFRT MERT4 74.30
Wiring Closed Wiring Base, Surface Mount 61-3060 64.50
Base Open Wiring Base, Cabinet Mount 61-5042 68.50
Add functionality to your existing MicroM chassis*.
Standard Local Reset Switch MED1 35.10
Standard Local Reset Switch
with Display Output MED2 58.30
Standard Local Reset Switch
with Remote Reset MED3 81.70
Option Standard Local Reset Switch
Boards with Communications MED7 129.00
Standard Local Reset Switch,
Display Output, and Remote Reset MED4 117.00
Standard Local Reset Switch with
Display Output, Communications MED5 142.00
Standard Local Reset Switch with
Display Output, Remote Reset,
and Communications MED6 175.00
19
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
Model Selection Guide
Catalog
Description Number Price
Step 1: Select Your BurnerLogix Chassis/Amplifier Module
120 VAC 50/60 Hz, with UV non-self-check amplifier YB110UV $1023.00
120 VAC 50/60 Hz, with UV self-check amplifier YB110UVSC 1262.00
120 VAC 50/60 Hz, with IR auto-check amplifier YB110IR 1192.00
120 VAC 50/60 Hz, with flame rectification amplifier YB110FR 1017.00
120 VAC 50/60 Hz, with direct-coupled amplifier, for
use with Phoenix and Insight scanners YB110DC 1192.00
Step 2: Select Your BurnerLogix Programmer Module
Keypad-selectable parameters, non-recycle operation,
modulation, open damper proving, 4 second FFRT YP100 905.00
Keypad-selectable parameters, non-recycle operation,
modulation, open damper proving, 2 second FFRT YP102 905.00
Keypad-selectable parameters, non-recycle operation,
fixed TFI times, pilot proving, modulation, open
damper proving, 1 second FFRT YP113 905.00
Keypad-selectable parameters, non-recycle operation,
modulation, open damper proving, indefinite pilot
hold, revert to pilot from auto, 4 second FFRT YP138 905.00
Keypad-selectable parameters, recycle operation,
modulation, 4 second FFRT YP200 699.00
Keypad-selectable parameters, recycle operation,
modulation, 2 second FFRT YP202 699.00
Keypad-selectable parameters, recycle operation, low
fire start, early spark termination, 4 second FFRT YP300 525.00
Keypad-selectable parameters, recycle operation, low
fire start, early spark termination, 4 second FFRT YP302 525.00
Step 3: Add an Optional BurnerLogix Display Module
Vacuum fluorescent display (VFD), Good -40° to 140°F BLV512 520.00
Liquid crystal display (LCD), Good -4° to 140°F BLL510 520.00
NEMA 4 remote mount kit for display, 4 foot cable 129-178-4 56.00
NEMA 4 remote mount kit for display, 8 foot cable 129-178-8 61.00
Step 4: Select a Wiring Base
4” x 5”, 4 foot pigtail wires, color coded and labeled 60-2810-1 93.20
4” x 7” closed base with terminal block and knockouts 60-2812-1 93.20
4” x 7” open base with terminal block 60-2814-1 93.20
Step 5: Add an Optional Expansion Module
Expansion module for first-out annunciation YZ300 996.00
Step 6: Select a Flame Scanner (See page 20 for details)
Non Self-Checking Scanner, 3 Ft. Flexible Cable UV1A3 160.00
Non Self-Checking Scanner, 6 Ft. Flexible Cable UV1A6 189.00
Infrared Scanner, 8 Ft Shielded Cable with 90° Head 48PT2-9003 252.00
Ultraviolet Self-Checking Scanner 120 VAC Shutter 45UV5-1009 1373.00
12" Flame Rod for Gas Flames, 1/2" NPT Connection 69ND1-1000K4 106.00
BURNER
CONTROLS
Features
Keypad-congurable parameters — no dip switches to set!
Smart LEDs provide status and lockout codes — and provide op-
eration without the need for the optional display
Alphanumeric display provides clear, concise messaging
Valve proof-of-closure during standby, startup, and shutdown
Modbus communications built in — adjustable baud rates allow for
easy adaptation to burner control system
Open wiring base with terminal block allows testing with control
installed; pigtail wiring base has color-coded and labeled leadwires
4-20 mA test jack signal
New design with smaller footprint saves
cabinet space
BurnerLogix
The Fireye Burner Logix System provides the proper burner sequenc-
ing, ignition and flame monitoring protection on automatically ignited
oil, gas, and combination fuel burners. In conjunction with limit and
operating controls, it programs the burner/blower motor, ignition and
fuel valves to provide for proper and safe burner operation.
A complete BurnerLogix system includes the YB110 chassis equipped
with a flame amplifier, appropriate flame detector, plug-in programmer
module, wiring base and optional alphanumeric display. The chassis/
flame amplifier module comes complete with mounting screws and
blank display module.
Interchangeable programmer modules allow for complete versatility
in selection of control function, timing, and flame scanning means. The
programming module determines functions like pre-purge time, recy-
cling or non-recycling interlocks, high fire proving interlock, and trial for
ignition timing of the pilot and main flame.
The BurnerLogix system can be used with ultraviolet, auto-check in-
frared, flame rod, self-check ultraviolet flame scanners, or direct coupled
by choosing the proper chassis/flame amplifier module.
BurnerLogix’ operational characteristics are
determined by the selection of the programmer
module (e.g. modulation, recycle, non-recycle,
fixed firing, flame failure response time, etc.). The
programmer module incorporates a plug-in design
for easy installation.
Wiring bases for the BurnerLogix control are
available pre-wired with 4 foot lead wires color
coded and marked for easy installation or with an integral terminal block
capable of accepting up to 2X 14 AWG wires. The wiring base terminal
block is available with knockouts for conduit, or open ended for cabinet
mounting.
Display Modules
The BurnerLogix system offers
vacuum fluorescent (VFD) and liq-
uid crystal (LCD) displays that can
be either plugged in or mounted
remotely to give full language
descriptors of current status and diagnostic lockout information.
Both displays contain a fully functional keypad so you can easily scroll
through the various menus to view the current operating status, and
review programmer configuration and lockout history.
Remote mounted displays meet NEMA 4X requirements.
BurnerLogix™ Burner Management System
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
20
V 10.2008
Flame Scanners
69ND1: Flame rod made
of high temperature resistant
metal. Can only be used to
detect gas flames. Rods are available in 12”, 18”, and 24” lengths.
UV1A: Ultraviolet miniature non self-
checking scanners suitable for fuel gases
and #2 oil. Non-replaceable tube. Mounting
collar 1/2” NPT.
48PT2: Lead sulfide scanner is designed to
detect low frequency IR signals from gas or oil
flames. Mounting collar is 1/2” NPT with straight
or 90° mounts. 8 ft. flexible conduit. Replaceable
sensor cell.
45UV5: Self-checking ultraviolet scanner for con-
tinuously fired applications where recycling in
infrequent or absent. The self-checking circuit
checks the electronics and the UV tube for
proper operation every 4 seconds during the firing
period. Suitable for fuel gases and oil. Replaceable UV
tube and shutter mechanism. Mounting 1” NPT. Must
be installed with metal shielding over the scanner leads.
Flame Amplifier Module
Flame amplifier modules are used with the
appropriate flame scanner to provide flame
scanning capability. Fireye offers ultraviolet
amplifiers and flame rectification amplifiers
for use with flame rods, photocells and auto-
check infrared amplifiers.
Self-checking ultraviolet scanners and
amplifiers should be used in applications
where burner firing operation is continuous
or where the burner is on for long periods
of time without cycling.
Flame Monitor Series Burner Control System
Model Selection Guide
Catalog Avail-
Component Description Number ability Price
Chassis 120VAC Chassis with Mounting
Screws and Dust Cover E110 $701.00
Program 30 Sec. Purge, 10/15 Sec. TFI, 4 Sec.
Module FFRT, Non-Recycle Modulation EP160 952.00
Display 2 Line x 16 Character LCD
Display with Keypad ED510 494.00
Flame Non Self-Checking Scanner, 3 Ft.
Scanner Flexible Cable, 1/2” NPT Conn. UV1A3 160.00
Non Self-Checking Scanner, 6 Ft.
Flexible Cable, 1/2" NPT Conn. UV1A6 189.00
Infrared Scanner, 8 Ft Shielded
Cable with 90° Head 48PT2-9003 252.00
Ultraviolet Self-Checking Scanner
120 VAC Shutter, 1" NPT Thread 45UV5-1009 1373.00
12" Flame Rod for Gas Flames,
1/2" NPT Connection 69ND1-1000K4 106.00
Standard Ultraviolet Amplier EUV1 373.00
Amplier Autocheck Infrared Amplier E1R1 552.00
Module Self-Check Ultraviolet Amplier EUVS4 625.00
Flame Rectication Amplier ERT1 367.00
Wiring Surface Mount 60-1386-2 105.00
Base Panel Mount 60-1466-2 105.00
BURNER
CONTROLS
Flame-Monitor Series
The Flame-Monitor Series provides
the proper burner sequencing, igni-
tion and flame monitoring protection
on automatically ignited oil, gas and
combination fuel burners.Inter change-
able programmer and flame amplifier
modules allow complete versatility in
selecting control function. The flame-
monitor control uses the same wiring
base as the Fireye D-Series and C-Series
Controls and is directly interchangeable
with most models with out rewiring.
The Flame-Monitor control can be
used with ultraviolet, AUTOCHECK® in-
frared, photocell, flame rod or self-check
ultraviolet flame scanners. Special features
include remote reset, remote display,
expanded annunciation of safety lockouts, programmability of safety
interlock messages, and remote data communications capability.
The complete Flame-Monitor control consists of a chassis, display
module, programmer, amplifier, scanner and a wiring base.
EP Programmer Module
The Fireye EP Programmer Modules
provide start-up programming, safe
start check, and flame monitoring su-
pervision. They ensure open damper
high fire purge interlock, proof of low
fire position and fuel valve end switch
safety checks.
A running interlock circuit constantly
monitors the limit switches, air flow
switches and fuel pressure switches
throughout the programmer. EP pro-
grammer modules will de-energize all fuel valve circuits within 4 seconds
following a flame failure or at the end the pilot-trail-for-ignition period
if no flame is detected.
The EP programmers provide a Check-Run switch to stop the control
in its firing sequence at any time (except MTFI) to aid in setup, start-up,
and check out of the burner and its associated interlocks.
EP programmers offer the following functions: an increase of purge
timing and air flow switch opened at the start of the operating cycle.
EP programmers include an RJ45 style connector to interface with the
ED510 display module. EP programmers store the burner cycle and on-
time history, as well as lockout history (with burner cycle and burner
hour time stamp).
ED510 Display Module
LCD backlit display with 2 lines of 16 characters each
RJ style connector
Mounts directly onto front face of programmers
Continuous display of current burner
status, including first out annunciation
in the event of a lockout condition
Remote display using DIN-sized opening
and remote mounting kit.
3-key keypad provides historical data
from the burner, the last 6 lockout condi-
tions (with burner cycle and burner hour
time stamp)
21
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
The 65UV5 flame scanner incorporates an inter-
nal single pole, single throw (normally open) flame
relay with a fixed on/off threshold to provide flame
on/flame off indication, eliminating the need for
an external flame amplifier.
The scanner uses an ultraviolet tube-type sen-
sor, and electromechanical self-checking shutter
mechanism. The NEMA 4X/IP66 housing is suit-
able for use in Class I Division II, Group C and D
hazardous environments.
The Fireye 65UV5 flame scanner is powered
by 24 VDC and includes an integral 10-foot
four-conductor cable with cable gland. Two
color-coded internal LEDs indicate flame sta-
tus (off/on) and alarm condition. These can
be viewed through the removable rear access
screw opening.
Model Selection Guide
Catalog
Description Number Price
Integrated Flame Scanner, 1” NPT Mounting Flange, 4 Second Flame Failure Response Time 65UV5-1004 $1544.00
BURNER
CONTROLS
65UV5 Integrated Flame Scanner with Internal Flame Relay
MB Series Industrial Multiburner Flame Safeguard System
The Fireye Multi-Burner Monitoring System controls the start-up
sequence and monitors the flame of up to 20 individual gas, oil or
combination gas/oil burners connected to a common valve train.
Dynamic on-board diagnostics check for faulty relays, proof of valve
closure, high and low fire switch interlocks, and shortened air switch.
The MB is even able to specifically identify which burner caused the
initial flame failure.
Plug-in flame sensor modules that can sense UV, UV self-check or
flame rod provide for easy replacement on an individual basis. Con-
figuration and startup time is reduced through use of on-board DIP
switches, which also allow sequencing and timing functions.
The MB-600S chassis directly powers pilot and main gas valves and
ignition transformers. The built in blower output, purge timing and
modulation control, let you add independent limits and a controller
to create a complete combustion control system for furnace, oven or
other multi-burner applications.
Specifications
Number of Burners: 20 max.
Pilot Proving Time: 7 seconds
Purge Time: 0 sec to 60 min
Pilot Trial for Ignition: 5, 10 or 15 seconds
Flame Failure Response Time: 3 (±0.5) seconds
Valve Operation: Simultaneous (all burners operate from one fuel train)
Supply Voltage: 120VAC, 50/60 Hz; Power Consumption: 25VA
Temperature Rating: -32° to 122°F (-36° to 50°C)
Contact Ratings: Fan Motor: 15 Amp Resistive; Others: 10 Amp Resistive
UV7R4
90° UV Scanner
UV7A4 UV Scanner
UV7SC
Self-Check
UV Scanner
Modulation for Purge and
Low Fire Start Control
Four
Auxiliary
Inputs
Valve Leak
Detection
Interface
LED indicator alert you to
process step and status
Connects to
optional Remote
Display Module
Optional
Expansion
Modules for
control of up
to 20 burners
Up to four
burner
amplifiers
mounted on
MB-600
A single MBPF amplifier module handles UV,
UV Self-Check and Flame Rod scanners Model Selection Guide
Tip: If your system has between 4 and 8 burners, select 1 MB-604E module and a
connecting cable. If your system has between 9 and 13 burners, select 1 MB-
608E module and a connecting cable. For systems that have 14 to 20 burners,
you can mix MB-604E and MB-608E modules to fit.
Catalog
Description Number Price
Step 1: Select a Chassis for your Multiburner Control System
120VAC 50/60Hz, Motherboard, Relay
Board, Logic Module, and Power Module.
4 Auxiliary Inputs, Purge Modulation,
Valve Leak Testing MB-600S $1769.00
120VAC 50/60Hz, Motherboard with RS-232
Communications, Relay Board, Logic
Chassis Module, Power Module. 4 Auxiliary Inputs,
Purge Modulation, Valve Leak Testing MB-632S 1903.00
120VAC 50/60Hz, Motherboard with RS-485
Communications, Relay Board, Logic
Module, Power Module. 4 Auxiliary Inputs,
Purge, Modulation, Valve Leak Testing MB-685S 1903.00
Step 2: Select a Flame Sensor Module
Sensor Plug-In Flame Sensor Module, UV/FR
Module Plastic Case with Mounting Screws MB-600PF 354.00
Step 3: For Systems with More than 4 Burners, Select Expansion Board Mod-
ules and Cables
Expansion Board for up to 4 Burners MB-604E 316.00
Expansion Expansion Board for up to 8 Burners MB-608E 638.00
Modules 6” Cable for Expansion Board 59-506-1 34.40
36” Cable for Expansion Board 59-506-3 48.60
Step 4: Select Optional Remote Display and Cable
Remote Display with Keypad MB510 448.00
Display 6 Ft. Cable for Remote Display 59-507-6 23.60
10 Ft. Cable for Remote Display 59-507-10 35.40
Step 5: Select One Flame Scanner for Each Burner on Your System
1/2” NPT Straight UV Scanner, 4 Ft. Flex
Conduit, Insulated Nylon Coupling UV7A4 181.00
1/2” NPT UV Scanner, NEMA 4, 4 Ft. Flex
Scanners Conduit, Insulated Nylon Coupling UV7A4W 241.00
and 1/2” NPT 90° UV Scanner, 6 Ft Shielded Cable UV7R4 148.00
Accessories 1” NPT Self-Check Scanner UV7SC 970.00
10 Ft Cable for UV7SC Self-Check Scanner 59-504-010 150.00
Scanner Support, Max Temp 200°F 36-935 35.60
Magnifying Lens Assembly 46-185 90.60
Magnifying Lens 46-186 22.20
Non-Magnifying Lens 46-187 28.20
1/2” NPTF Insulated Nylon Coupling 35-319 17.40
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
22
V 10.2008
Flame Relays and Burner Control Units
IFS 258 IFS 110IM BCU 370
Operating Time < 24 Hours < 24 Hours > 24 Hours
Ignition Type Direct Direct Direct or Pilot Burner
Signal Line Length 75M Max 50M Max 50M Max
Behavior at Flame
Failure
Switchable: Fault Lockout
or Restart
Fault Lockout
and/or Restart
Programmable
Gas Valve Outputs 122
IFS 258 Burner Control Unit
For use in single- and multiburner atmospheric or forced-air burner systems. Can be used
with on/off, high/low or proportional control. Add external timer to provide purge timing.
Compatible with ame rods or UV detectors
Front panel indicators display burner unit on,
flame on, and flame failure information
Start/stop/reset switch on front of unit
Can be programmed to restart or immediate
fault lockout following flame failure
CSA, FM approved
Model Selection Guide
Pilot Flame Catalog
Description Establishing Period Number Price
Burner control unit for intermittent operation with switchable
fault lockout or restart, FFRT 2 seconds
IFS 258T-3/2R 3 seconds 84620420 $307.00
IFS 258T-5/2R 5 seconds 84620440 307.00
IFS 258T-10/2R 10 seconds 84620460 307.00
IFS 110IM Burner Control Unit
Automatic burner control for ignition and control of gas burners in gas-firing installations of
all types. Designed for high cycling frequency and long life.
Flame control by means of ame rods or
UV detectors
Performs ame simulation check before
starting burner and after switching off
Semiconductor output for ignition trans-
former — no switch contacts
High cycling frequency
Remote reset
External fault indication
FM approved
Can be used for multiburner control by
adding flame relay IFW 15T
Model Selection Guide
Catalog
Description Number Price
Flame relay. Use with IFS 110IM burner control
for multiburner apps.
IFW 15T-N Flame Relay 84359100 $200.00
Pilot Flame Catalog
Description Establishing Period Number Price
Burner control unit for intermittent pilots, FFRT 2 seconds, fault
lockout and restart following flame failure
IFS 110IMT-3/2/2N 3 seconds 84367700 $414.00
IFS 110IMT-5/2/2N 5 seconds 84367710 414.00
IFS 110IMT-10/2/2N 10 seconds 84367720 414.00
Burner control unit for intermittent operation FFRT 2 seconds,
restart following flame failure
IFS 110IMT-W-3/2/2N 3 seconds 84367750 434.00
IFS 110IMT-W-5/2/2N 5 seconds 84367760 434.00
IFS 110IMT-W-10/2/2N 10 seconds 84367770 434.00
Model Selection Guide
IFW 15T Flame Relay
Detect and signal existing flame.
Compatible with ame rods or UV detectors
Potential-free contacts
Integrated ON lamp
Use with IFS 110IM for multiburner control
Great for letting your PLC know when ame is present
Add an IFW 15T
ame relay to your
IFS 110 IM for
multiburner control.
Choosing the Right
Kromschroder Burner Control
BURNER
CONTROLS
23
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
Model Selection Guide
Catalog
Description Number Price
UVS 8T Ultraviolet Detector 84333120 $134.00
UV Replacement Tube 74960445 111.00
UVS 8T Ultraviolet Flame Detector
For use in forced and induced draft burners, ovens, gas-fired boilers, industrial furnaces, and
installations for the flaring of excess gas.
High sensitivity over an ambient temperature range -40° to 176°F
Insensitive to sunlight, daylight, infrared radiation, and incandescent lamps
UV tube life expectancy of 10,000 operating hours
Protects against interruptions or short circuits in the ame
signal line
Rugged aluminum construction with integral 1/2” NPTF
threaded collar and 6-foot leads
FM approved
BCU 370 Burner Control Unit
Controls, ignites, and monitors industrial forced-air burners of unlimited capacity in
intermittent or continuous operation. Can be used for direct-ignited or pilot-burner systems.
Controls fan and buttery valve, monitors gas and air pressure
Manual operating mode and informative operating, warning, and fault messages make startup, service, and
and maintenance simple
Optional integrated tightness control function checks valves with a DG gas pressure switch
Quick-start option allows standard-compliant startup of forced air burner without pre-purge after normal
shutdown
Programmable via optical interface and BCSoft PC software
Model Selection Guide
Catalog
Description Number Price
For controlling, igniting, and monitoring industrial forced-air burners, intermittent operation, ionization or UV control.
120 VAC 50/60 Hz power, fan (blower) and butterfly valve control
BCU 370QFEU0D1 No ignition unit, flame control DGmax 88600122 $530.00
BCU 370QI1FEU0D1 Single-pole electronic ignition, flame control DGmax 88600249 650.00
BCU 370QI1FEU0D1B1 Single-pole electronic ignition, flame control DGmax,
ProfiBUS-DP interface 88600236 858.00
BCU 370QFEU0D3B1-3 No ignition unit, integrated tightness control, ProfiBUS-DP interface
and butterfly valve control over ProfiBUS 88600121 1111.00
Opto Adapter and BCSoft CD-ROM for BCU 370s 74960437 263.00
BURNER
CONTROLS
Coming soon to Lesman.com:
Buy Kromschroder burner controls from
our secure web store!
When you need to learn more, the
Lesman website has:
Downloadable specications
Dimensional drawings
24/7/365 availability
Visit us anytime at www.lesman.com
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
24
V 10.2008
Pressure Switches for Gas Applications
DG..VT Safety Limit Pressure Switches
Diaphragm-actuated safety limit switch controls rising or falling pressures that must not
overshoot or undershoot a set limit
value, and controls the minimum
or maximum gas inlet pressure of a
gas control line.
For use with natural gas and air
Die-cast aluminum base, glass-lled PBT
switch housing, NBR diaphragm, and
polycarbonate cover
Available with Valvario mount for direct
connection to Kromschroder modular
valve trains
Ambient temperatures 5° to 140°F
4-pin DIN/Amp plug wiring connector
Model Selection Guide
Adjustable Catalog
Description Range Connection Number Price
DG pressure switch with 4-pin plug, socket, and 18” flexible leads
DG 17VCT6-6W 0.8” to 6.8” WC 1/8 NPTM 84448040 $49.00
DG 40VCT6-6W 2.0” to 16” WC 1/8 NPTM 84448840 49.00
DG 110VCT6-6W 12” to 44” WC 1/8 NPTM 84448440 49.00
DG 300VCT6-6W 40” to 120” WC 1/8 NPTM 84448940 49.00
DG 17VCT8-6W 0.8” to 6.8” WC 1/4” NPTM 84448090 49.00
DG 40VCT8-6W 2.0” to 16” WC 1/4” NPTM 84448890 49.00
DG 110VCT8-6W 12” to 44” WC 1/4” NPTM 84448490 49.00
DG 300VCT8-6W 40” to 120” WC 1/4” NPTM 84448990 49.00
DG 17/VCT1-6W 0.8” to 6.8” WC Valvario 75454583 78.00
DG 40/VCT1-6W 2.0” to 16” WC Valvario 74214174 78.00
DG 110/VCT1-6W 12” to 44” WC Valvario 75454585 78.00
DG 300/VCT1-6W 40” to 120” WC Valvario 75454586 78.00
DG Pressure Switches
Monitors positive air and gas
pressures, negative or differential
air pressures in industrial and
commercial applications.
Accurate repeatable switching action
with low hysteresis
Die-cast aluminum alloy base, glass ber-
reinforced plastic switch housing, nitrile
rubber diaphragm, and high-quality
injection-molded plastic covers
One normally open and one normally
closed contact in each switch (5A resis-
tive or 0.5A inductive
Automatic and manual reset models
8A quick-acting fuse for short circuit
protection
FM approved, cULus listed
Model Selection Guide
Adjustable Catalog
Description Range Connection Number Price
DG..T pressure switch with 110V control lamp (green) for positive,
negative, and differential pressure, automatic reset
DG 6T 0.2” to 2.4” WC 1 x 1/4” NPT 84447800 $64.00
DG 10T 0.4” to 4” WC 1 x 1/4” NPT 84447810 64.00
DG 50T 1.0” to 20” WC 1 x 1/4” NPT 84447820 64.00
DG 150T 12” to 60” WC 1 x 1/4” NPT 84447830 64.00
DG 500T 40” to 200” WC 1 x 1/4” NPT 84447840 64.00
DG 6T 0.2” to 2.4” WC 2 x 1/4” NPT 84447802 63.00
DG 10T 0.4” to 4” WC 2 x 1/4” NPT 84447812 63.00
DG 50T 1” to 20” WC 2 x 1/4” NPT 84447822 63.00
DG 150T 12” to 60” WC 2 x 1/4” NPT 84447832 63.00
DG 500T 40” to 200” WC 2 x 1/4” NPT 84447842 63.00
DG..HT pressure switch with manual reset, locks on pressure rise
DG 10HT 0.4” to 4” WC 2 x 1/4” NPT 84447912 77.00
DG 50HT 1.0” to 20” WC 2 x 1/4” NPT 84447922 77.00
DG 150HT 12” to 60” WC 2 x 1/4” NPT 84447932 77.00
DG 500HT 40” to 200” WC 2 x 1/4” NPT 84447942 77.00
DG..NT pressure switch with manual reset, locks on pressure fall
DG 10NT 0.4” to 4” WC 2 x 1/4” NPT 84447962 77.00
DG 50NT 1.0” to 20” WC 2 x 1/4” NPT 84447972 77.00
DG 150NT 12” to 60” WC 2 x 1/4” NPT 84447982 77.00
DG 500NT 40” to 200” WC 2 x 1/4” NPT 84447992 77.00
PRESSURE
CONTROLS
The new RAECO Rents instrumentation
catalog is now available! Get yours FREE!
• LookingforportableLELmonitorsorcombustioneciencyanalyzers?Checkwith
ourpartnersatRAECO!
• Rentalsavailableonadaily,weekly,ormonthlybasis
• Allparts,accessories,andsoftwareavailable
• Automatic5%rentalfeediscountwhenyourentonlineatwww.raeco.com
Visit www.raeco.com to request a print catalog or download the free PDF.
25
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
Butterfly Valves and Actuators
BV Butterfly Valves
High accuracy valves for control of gas flow rates. Mount on IC 20 or IC 40 actuators to
regulate flow rates for modulating or stage-controlled combustion systems.
Low leakage rate and pressure loss
Other models available for ue gas and high temperature air ow rates to 840°F. Call Lesman for details
Model Selection Guide
Temperature Bore Nominal Reduced Compatible Catalog
Model Range Size Diameter Nominal Diam. Actuator Number Price
Butterfly valve for continuous control of gas flow rates, ratio of 10:1. Maximum inlet pressure 7.25 PSI.
BVG 40TW05 -4° to 140°F Full 1 1/2” IC 20 or IC 40 74105790 $196.00
BVG 65TW05 -4° to 140°F Full 2 1/2” IC 20 or IC 40 74105792 226.00
BVG 50TW05 -4° to 140°F Full 2” IC 20 or IC 40 74105791 208.00
BVG 80TW05 -4° to 140°F Full 3” IC 20 or IC 40 74105793 257.00
BVG 100TW05 -4° to 140°F Full 4” IC 20 or IC 40 74105794 273.00
BVG 40/32TW05 -4° to 140°F 1X Reducing 1 1/2” 1 1/4” IC 20 or IC 40 74214264 255.00
BVG 50/40TW05 -4° to 140°F 1X Reducing 2” 1 1/2” IC 20 or IC 40 74214263 294.00
BVG 65/50TW05 -4° to 140°F 1X Reducing 2 1/2” 2” IC 20 or IC 40 74214262 316.00
BVG 80/65TW05 -4° to 140°F 1X Reducing 3” 2 1/2” IC 20 or IC 40 74105783 361.00
BVG 100/80TW05 -4° to 140°F 1X Reducing 4” 3” IC 20 or IC 40 74105784 376.00
BVG 40/25TW05 -4° to 140°F 2X Reducing 1 1/2” 1” IC 20 or IC 40 74214267 255.00
BVG 65/40TW05 -4° to 140°F 2X Reducing 2 1/2” 1 1/2” IC 20 or IC 40 74214265 316.00
BVG 50/32TW05 -4° to 140°F 2X Reducing 2” 1 1/4” IC 20 or IC 40 74214266 294.00
BVG 80/50TW05 -4° to 140°F 2X Reducing 3” 2” IC 20 or IC 40 74105875 361.00
BVG 100/65TW05 -4° to 140°F 2X Reducing 4” 2 1/2” IC 20 or IC 40 74105782 401.00
Need a buttery
valve for ue gas
or high temperature
air ow rates? Call
Lesman for pricing
and availability.
Compatible Valve Actuators for BV Butterfly Valves
Reversible gear motors to transmit rotary movements between 0° and 90°.
IC 20 for basic applications with continuous or three-point step control, automatic/manual mode changeover
for easy commissioning. IC 20..E is controlled by 0/4-20 mA or 0-10V signal
IC 40 for complex applications with programmable functions for exible adjustment to the process. Compat-
ible with BCSoft for data monitoring, troubleshooting, and programming
Model Selection Guide
BUTTERFLY
VALVES
Torque Run Time Controlling Catalog
Description (Lb-in) (Over 90° Stroke) Signal Number Price
IC 20 Reversible gear motor, 120 VAC, 50/60 Hz
IC 20-07Q2 22 Lb-in 7.5 seconds Three-point step 74105712 $311.00
IC 20-15Q3 26.5 Lb-in 15 seconds Three-point step 74105713 311.00
IC 20-30Q3 26.5 Lb-in 30 seconds Three-point step 74105714 311.00
IC 20-60Q3 26.5 Lb-in 60 seconds Three-point step 74105715 311.00
IC 20-07Q2E 22 Lb-in 7.5 seconds Continuous 74105998 741.00
IC 20-15Q3E 26.5 Lb-in 15 seconds Continuous 74105999 741.00
IC 20-30Q3E 26.5 Lb-in 30 seconds Continuous 74106000 741.00
IC 20-60Q3E 26.5 Lb-in 60 seconds Continuous 74106001 741.00
Torque Catalog
Description (Lb-in) Additional Input/Output Functions Number Price
IC 40 Reversible gear motor, 100-230 VAC, 50/60 Hz
IC 40TA2 22 Lb-in 74105760 $603.00
IC 40TA2A 22 Lb-in 4-20 mA input 74105761 620.00
IC 40TA2R10 22 Lb-in 1000Ω feedback potentiometer 74105762 691.00
IC 40TA2AR10 22 Lb-in 4-20 mA input and 1000Ω feedback potentiometer 74105763 746.00
IC 40TSA3 26.5 Lb-in Safety closing function 74105764 736.00
IC 40TSA3A 26.5 Lb-in Safety closing, 4-20 mA input 74105765 795.00
IC 40TSA3R10 26.5 Lb-in Safety closing, 1000Ω feedback potentiometer 74105766 820.00
IC 40TSA3AR10 26.5 Lb-in Safety closing, 4-20 mA input, 1000Ω feedback potentiometer 74105767 879.00
Loose (/B) Assembled /E)
IC 20/40 Attachment Set 74921671 $74.00 74921747 $69.00
IC 20/40 Adapter - Free Shaft End 74921676 60.00 74921677 68.00
IC 20/40 Adapter - Manual Adjustment 74921678 47.00 74921679 52.00
IC 20/40 Adapter - Square Shaft 74921674 74.00 74921675 69.00
IC 40 Accessory: Fastening Set IC-BV 74921082 8.00 74921084 9.00
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
26
V 10.2008
SOLENOID
VALVES
Compact Solenoid Valves
Valvario® VAS Safety Shut-Off Solenoid Valves
Normally closed solenoid valves for gas. For safeguarding and controlling air and
gas supply to gas burners and appliances. For use in gas control and safety systems
in all sectors of the iron, steel, glass, and ceramics industries, plus commercial heat
generation in packaging, paper, and food industries.
Modular design saves space and piping work
Main gas valve, pilot valve, regulator and pressure switch are all available for direct stack mounting
for one small modular footprint
Changeable mounting plates make it easy to reduce input/output size and ange size. Reduces need
for keeping multiple sizes in inventory
Modular-mount mercury-free pressure switch has test port and <25% deadband
Can be equipped with Proof of Closure visual indicator
High ow rate and low pressure drop
CSA, FM, CE approvals Model Selection Guide
Valve Inlet/Outlet Catalog
Series Size Flange Size Number Price
VAS Quick Opening, NPT Threaded Connection
VAS 1T10N/NQ 1 3/8” 88001831 $181.00
VAS 1T15N/NQ 1 1/2” 88001832 181.00
VAS 1T20N/NQ 1 3/4” 88001842 215.00
VAS 1T25N/NQ 1 1” 88001830 224.00
VAS 2T25N/NQ 2 1” 88001849 288.00
VAS 2T32N/NQ 2 1 1/4” 88001850 288.00
VAS 2T40N/NQ 2 1 1/2” 88001851 296.00
VAS 2T50N/NQ 2 2” 88001852 296.00
VAS 3T40N/NQ 3 1 1/2” 88001853 404.00
VAS 3T50N/NQ 3 2” 88001854 404.00
VAS 3T65N/NQ 3 2 1/2” 88001855 432.00
VAS Quick Opening, ANSI Flanged Connection, No Accessory Connection
VAS 6T65A05NQP 6 2 1/2” 88200132 854.00
VAS 7T80A05NQP 7 3” 88200148 1357.00
VAS 8T100A05NQP 8 4” 88200162 1835.00
VAS 9T125A05NQP 9 5” 88200160 2923.00
VAS Quick Opening, ANSI Flanged Connection, Two Screw Plug
Connections for Accessory Connections at Right Inlet/Outlet
VAS 6T65A05NQP/PP/PP 6 2 1/2” 88200385 1028.00
VAS 7T80A05NQP/PP/PP 7 3” 88200390 1533.00
VAS 8T100A05NQP/PP/PP 8 4” 88200394 2014.00
VAS 9T125A05NQP/PP/PP 9 5” 88200427 3106.00
VAS Slow Opening, NPT Threaded Connection
VAS 1T10N/LQ 1 3/8” 88001856 226.00
VAS 1T15N/LQ 1 1/2” 88001857 226.00
VAS 1T20N/LQ 1 3/4” 88001858 269.00
VAS 1T25N/LQ 1 1” 88001859 269.00
VAS 2T25N/LQ 2 1” 88001860 333.00
VAS 2T32N/LQ 2 1 1/4” 88001861 333.00
VAS 2T40N/LQ 2 1 1/2” 88001862 342.00
VAS 2T50N/LQ 2 2” 88001863 342.00
VAS 3T40N/LQ 3 1 1/2” 88001864 450.00
VAS 3T50N/LQ 3 2” 88001865 450.00
VAS 3T65N/LQ 3 2 1/2” 88001869 479.00
VAS Slow Opening, ANSI Flanged Connection, No Accessory Connection
VAS 6T65A05LQP 6 2 1/2” 88200133 936.00
VAS 7T80A05LQP 7 3” 88200149 1439.00
VAS 8T100A05LQP 8 4” 88200163 1917.70
VAS Slow Opening, ANSI Flanged Connection, Two Screw Plug
Connections for Accessory Connections at Right Inlet/Outlet
VAS 6T65A05LQP/PP/PP 6 2 1/2” 88200387 1110.00
VAS 7T80A05LQP/PP/PP 7 3” 88200391 1615.00
VAS 8T100A05LQP/PP/PP 8 4” 88200395 2095.00
Specifications
Inlet Pressure: (pe): 7 PSIG max
Non-Operational Pressure: FM approved: 10 PSIG; CSA approved: 5 PSIG
Flow Adjustment: Limits max ow between 20% and 100%. On VAS 1-3 sizes,
the setting can be monitored on an indicator
Adjustment of Start Gas Rate: 0% to 70%
Opening Times: VAS/N quick opening: 1sec; VAS/L slow opening: up to 30 sec
Closing Time: <1 second
Ambient Temperature: -4° to 140°F
Safety Valve: Class A, Group 2, pursuant to EN 13611 and EN 161; FM research
class 7410 and 7411, ANSI Z21.21, CSA 6.5
Materials: IP65 enclosure; Valve housing: Aluminum, Valve seal: NBR
Voltage: 120 VAC, 50/60 Hz
Current Consumption (at 68°F): Pickup: 1.8 amp; Holding: 0.3 amp
Switching Frequency: 5x per minute, except VAS 9: Once per minute
Switching Cycles: 0.1 amp: 500,000; 0.5 amp: 300,000; 1 amp: 200,000; 3 amp:
100,000
Flow Rates
27
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
Comparing ASCO Combustion Valves
8030 8040 8210 8214 8215 8262
Valve
Parts In
Contact
with
Fluids
Brass body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
302 SS springs
Aluminum body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
302 SS springs
Zinc-plated steel pipe
plug
Brass body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
Aluminum body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
302 SS springs
Zinc-plated steel pipe
plug
Aluminum body
305 SS core tube
NBR seals/disc/
diaphragm
430F SS core/plugnut
302 SS or 17-7 PH
springs
Copper shading coil
CA core guide
305 SS core tube
Brass body
305 SS core tube
NBR seals/disc
430F SS core/plugnut
Copper shading coil
Inconel 600 springs
Acetal core guide
PTFE rider ring
Approvals UL, FM, CSA UL, CSA,
FM (3/8” to 3/4” only)
UL, FM, CSA UL, FM, CSA UL, CSA,
FM (except 8215A090
and 8215A040)
UL, FM, CSA
Looking for another ASCO solenoid valve? Call Lesmans solenoid valve specialists at 800-837-1700. We stock deep!
SOLENOID
VALVES
Solenoid Valves for Combustion Systems
Model Selection Guide
120 volts AC/60 Hz — All Valves Shown Here are Normally Closed (Closed when De-Energized), Suitable for Use in Fluids to Maximum Temperatures 125°F
Operating Pressure Watt Rating/ Solenoid Valve Repair Kit Replacement Coil
Cv Gas Differential (PSI) Class of
Pipe Orifice Flow Capacity Coil Catalog Price Catalog Price Catalog Price
Size Size Factor BTU/Hr Min. Max. Insulation Number Each Number Each Number Each
Direct Acting Gas Shutoff Valves
1/8” 5/16” 1 53,700 0 15 6.1/F 8040H006 $64.00 318247 $66.00 238210-032-D $61.00
1/4” 9/32” 0.96 51,700 0 40 10.1/F 8262G078 65.00 306631 47.00 238610-032-D 69.00
1/4” 5/16” 1.1 59,000 0 15 10.1/F 8040H007 65.00 318247 66.00 238210-032-D 61.00
3/8” 3/8” 1.8 97,000 0 15 10.1/F 8030G068 154.00 306628 104.00 238610-032-D 69.00
1/2” 7/16” 2.8 151,000 0 8 10.1/F 8030G069 157.00 306629 108.00 238610-032-D 69.00
1/2” 3/4” 5.4 291,000 0 2 10.1/F 8040G022 127.00 306633 63.00 238610-032-D 69.00
3/4” 3/4” 9.5 512,000 0 2 10.1/F 8040G023 132.00 306633 63.00 238610-032-D 69.00
1” 1-5/8” 16.8 900,000 0 0.5 15.4/F 8040C004 158.00 304079 104.00 099257-001-D 91.00
Pilot Operated Gas Shutoff Valves
3/8” 5/8” 2.8 150,000 0 50 10.1/F 8210G074 179.00 304076 128.00 238610-032-D 69.00
3/8” 3/4” 3.4 183,000 0 50 10.1/F 8215G010 135.00 302350 104.00 238610-032-D 69.00
1/2” 5/8” 3.6 193,000 0 50 10.1/F 8210G075 179.00 304076 128.00 238610-032-D 69.00
1/2” 3/4” 4.4 238,500 0 50 10.1/F 8215G020 135.00 302350 104.00 238610-032-D 69.00
3/4” 5/8” 5.0 295,000 0 50 10.1/F 8210G076 196.00 304076 128.00 238610-032-D 69.00
3/4” 3/4” 5.1 247,500 0 50 10.1/F 8215G030 139.00 302350 104.00 238610-032-D 69.00
3/4” 1-5/8” 11 580,000 0 50 15.4/F 8215 135 250.00 302352 184.00 099257-001-D 91.00
1” 1-5/8” 21 1,119,000 0 25 15.4/F 8215B050 252.00 302352 184.00 099257-001-D 91.00
1-1/4” 1-5/8” 32 1,730,000 0 25 15.4/F 8215B060 252.00 302352 184.00 099257-001-D 91.00
1-1/2” 1-5/8” 35 1,900,000 0 25 15.4/F 8215B070 292.00 302352 184.00 099257-001-D 91.00
2” 2-3/32” 60 3,251,000 0 25 15.4/F 8215B080 428.00 302353 221.00 099257-001-D 91.00
2-1/2” 3” 117 5,821,000 0 5 28.2/F 8215A090 835.00 302354 362.00 206409-011-D 188.00
3” 3” 138 7,430,000 0 5 28.2/F 8215A040 835.00 302354 362.00 206409-011-D 188.00
Gas Shutoff Valves with Waterproof Enclosures
3/8” 3/4” 3.4 183,000 0 5 17.1/F 8214G010 135.00 316233 143.00 238610-132-D 83.00
1/2” 3/4” 4.4 238,500 0 5 17.1/F 8214G020 135.00 316233 143.00 238610-132-D 83.00
3/4” 3/4” 5.1 247,500 0 5 17.1/F 8214G030 139.00 316233 143.00 238610-132-D 83.00
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
28
V 10.2008
STACK GAS
ANALYZER
Refineries and power plants measure excess oxygen to improve their
energy efficiency and reduce fuel consumption.
In most oxygen analyzers, the electronic sensor comes in direct contact
with the sample gas, so you have to remove the hot probe every time
you service the sample gas filter or the sensor. And, you need to stock
probe-length-specific spare parts inventory for these systems.
Cosa Zircomat oxygen analyzers are more user-friendly. In the Zircomat
system, the sample gas is deflected to the sensor. To increase safety, the
probe always stays in the stack. The small, hand-held oxygen detector is
quickly detachable for service. And, one detector fits all Zircomat probes,
any model any length!
Small and easily detachable, the Zircomat detector can be serviced
without removing the probe from the flue stack. You won’t need to shut
down your plant just to remove the probe. A replaceable sample gas
diffuser on the end of the detector provides sensor protection.
The microprocessor-based transmitter has a large LED display for
oxygen concentration and a 4-20 mA isolated output signal. Its simple
to run a manual or automatic calibration check using known value gases
to ow a calibration gas through the detectors calibration gas port —
without removing the detector from the process.
The Zircomat transmitter can monitor and analyze performance of up
to seven parameters online. Failure to meet any of these specifications
will activate alarm contact. The self-cleaning probe feature is program-
mable from the keypad, and activates a solenoid valve for blow-back
probe cleaning. You can use the interactive panel to customize response
time to process changes to suit existing combustion
control parameters.
Features
Simple to install and maintain
One detector ts all Zircomat
probes
Detector removes for easy clean-
ing and repair; probe stays in
place
Calibrates automatically
Field selectable ranges
Selectable memory hold feature
Hi-Lo and self-diagnostic alarms
Interactive message panel
Isolated 4-20 mA output signal
Extractive sample cell available
Stack Gas In
Stack
Wall
Detector
Probe Stack Gas Out
Specifications
Sensor: Zirconia oxide
Measurement Range: 0-2%, Up to 50%
0.5% steps
Output Signal: 4-20 mA, linear isolated
Accuracy: ±2% of reading; Repeatability: ±0.5%
Response Time: Initial 0.1 sec./90% 7 sec; Warm Up Time: 5 minutes
Probe Materials: ZFK/ZTB: Steel, ZTA: Carbide, ZFK-ST: Mullite
Probe Flange: ZTB/ZFK/ZFK-ST: 4” 150#RF; ZTA: 2.5” 150#RF
Cable: 20 ft. Sealtite flexible conduit, up to 1000 ft. optional
Air Requirement: Self-Cleaning Probe: 15 SCFM, 40-120 PSI; ZTA Probe Sample
Loop: 10-20 SCFH
ZTA Probe: Low temperature alarm below 100°C, volt; free 1A 115V contact
closure
Transmitter
Ambient Temperature: 0-130°F
High/Low Alarms: Rated N/O volt free 2A 250V
Contacts: Outputs: Rain resistant; Inputs: Autocal start/inhibit; Alarm: Failure
in service, maintenance blow down
Calibration: Manual or automatic
Output Signal Hold: Selectable, for self-cleaning or maintenance
Finish: Epoxy painted steel/SS
Mounting: Wall, panel, or 2” pipe mount
Options: Combustion efficiency, RS485 communication, remote calibration
unit with solenoids and flow meter; Hazardous area transmitter
Selecting the Right Zircomat Analyzer System
Stack Gas and Combustion Efficiency Analyzers
Zircomat In-Situ Stack Gas Oxygen Analyzer
Fuel Type Gas or Oil Gas or Oil Coal, Oil, or Gas Coal, Oil, or Gas
Sample Gas Up to 1150°F Up to 2200°F Up to 2900°F Up to 1150°F
Available
Probe Lengths
12, 20, 30, 40, 60, 80,
100, 120, 140
20, 40 20, 30, 40, 60 12, 20, 30, 40, 60, 80,
100, 120, 140
Applications Utility/Industrial Power
Boilers, Process Heaters,
Marine Boilers, Drying
Furnaces, Steam Gener-
ators, Inert Gas Generators
Process Heaters, Steam
Generators, Power Boilers
Soaking Pits, Blast Furnaces,
Coke Ovens, Incinerators,
Glass Furnaces, Boiler
Fireboxes, Process Heaters,
Reheat Furnaces
Utility/Industrial Power
Boilers, Incinerators, Blast
Furnaces, Coke Ovens, Black
Liquor Boilers
Use Model... ZRM-ZFK ZRM-ZFK-ST ZRM-ZTA ZRM-ZTB
Prices Start at... $4796.00 $4996.00 $7216.00 $5073.00
Please issue all orders to: Cosa Instruments, c/o Lesman Instrument Company
Call Lesman for
help specifying the
right model for
your application.
Looking for COSA portable combustion
efciency analyzers? Call Lesman.
29
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
EFFICIENCY
ANALYZER
Portable Combustion Efficiency Analyzers
Testo 330-2 Industrial Combustion Analyzer
• MeasuresO2,CO,NO(CO2andNOxcalculated),temperature°F,pressure,
eciency,andexcessair
• Automaticsensorprotection(COdilutionto30,000ppm);Automatic
moistureprotection;includesvisualalarmandpumpshut-o
• Datalogs200measuringrecords,withaddressandsystemnumbers
• Infrared(IrDA)interfaceforworkingwithahandheldPDA,infraredprinter,
orlaptopPC,USBinterfaceforcongurationanddatauploads
Testo 330-2 Kit comes with 12" click-and-go probe, 7' hose, rechargeable Lithium Ion battery, charger with cord,
infrared printer with paper, carrying strap, standard case with foam insert, USB cable, software, and user manual.
$100.00
Daily
$250.00
Weekly
$700.00
Monthly
$3590.00
to Buy
Testo 335 Portable Flue Gas Analyzer $123.00
Daily
$410.00
Weekly
$1025.00
Monthly
$3795.00
to Buy
• MeasuresO2,CO,NOdraft,ow,velocity,mass,dierentialpressure
• AutomaticdilutionexpandsCOrangeto50000ppm,NOto6000ppm
• Pre-calibratedplug-and-playsensorseliminatetheneedforcalibrationgas
inallbutthemostdemandingapplications
• Dataloggingforuptotwohours
• Infraredinterfaceforprinter,handheldPDA,orlaptopPC
Testo 335 NOx Kit comes with standard 12" probe, 7-foot Teon®-lined hose, Type K thermocouple, sensors for
NOx, O2, CO, and NO, infrared printer with 6 rolls of paper, power adapter with Lithium Ion battery, extra battery and
charger, 10-pack of lters, Easy Emission software, USB cable, and standard case with foam insert.
866-RENT-EHS
(866)736-8347
Testo 350-XL Portable Emissions Analyzer Kit
• SensorsforO2,CO,NO,NO2(NOx),SO2
• Temperature-controlledsensorsextendtestingrange
• SampleconditioningwithPeltiergaschillerandwaterremovalsystem
• Dilutionsystem40:1max.extendsCOrangetowellover100,000ppm
• Freshairpurge;Rapidset-upforeasymeasuring
• Largebacklitdisplayhasmultipagescroll-down,zoomfunction,andpull-
down menus
Testo 350-XL Engine Kit comes with gas sensors for CO, O2, NO, NO2 and SO2, control unit, particulate lters,
printer paper, carrying case and strap, transport case with sliding drawer, 12" engine probe with 7' hose and 12"
thermocouple probe with 16' cable, RS232 cable, software, and 16' remote control cable.
$200.00
Daily
$500.00
Weekly
$1500.00
Monthly
$8990.00
to Buy
$100.00
Daily
$200.00
Weekly
$700.00
Monthly
CA-Calc 6213 Combustion Analyzer for O2, CO, NO, SO2
Real-time measurement seconds after power-up
Calculates efciency, excess air, CO2, and emission rates, provides NO2 values
Adjustable CO high limit pump shutdown; Adjustable O2 reference
Data history sorted by system, or individual sample for printouts and report
generation
CA-Calc 6213 includes12”probewith9-footsamplingtube,Teon-linedsamplingprobe,watertrap,
carryingcase,ACadapter,fourCAlkalinebatteries,andoperationmanual.
Our partners at RAECO make it easy to get the combustion efficiency analysis equipment you need,
without a major outlay of cash. When you need portable combustion analyzers for short-term use, RAECO
Rents! has units for daily, weekly, or monthly rental. So you get the best monitor/analyzer for your needs,
just for the time you need it. No big purchase, no maintenance and upkeep costs. Call 866-736-8347 and
ask for Patricia or Rick.
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
30
V 10.2008
COMBUSTIBLE
GAS MONITORS
Portable Combustible Gas Detectors from
$40.00
Daily
$125.00
Weekly
$300.00
Monthly
$1239.00
to Buy
MSA Altair4 Multigas Detector with Pump Probe
• High-contrastLCDshowssimultaneousreadingsforLEL,CO,H2S,andO2
• Ultra-brightLEDs,95dBhorn,andvibratingalarmsforwarningsyoucan'tmiss!
• MotionAlertsignals"mandown"bydetectinglackofmotionfor30seconds,
InstantAlertletsyousoundamanualalarmtowarnothersofhazards
• 16-hourbatteryruntimewhenfullycharged
Altair 4 kit includes detector with universal pump probe, sensors for 0-100% Pentane LEL, 0-25% O2, 0-999 ppm CO,
and 0-200 ppm H2S, power supply/charger, MSA-Link software CD-ROM, JetEye infrared adapter with USB connector, user
manual, and carrying case.
Passport® PID II Personal Organic Vapor Monitor
• Range0–10,000ppmwithnodilutiontubeorinternaladjustment
• Peak,short-termexposure(STEL)andtime-weightedaverage(TWA)
• 69pre-programmedand10user-denedresponsefactors
• DigitaldisplayshowsnumericandbargraphdetailofVOCconcentration
• 5-secondaccesstochangebatterypack,cleanorreplacelamp
Passport PID II includes NiCad battery pack, 110 VAC charger, 10' coiled Teon sampling line, PVC case,
protective rubber boot, pistol grip with wrist strap, and 8" screw-on probe.
$50.00
Daily
$250.00
Weekly
$700.00
Monthly
Call for pricing on a
gently-used model
• SimultaneouslymonitorsanddisplaysreadingsforO2,CO,H2S,and%LEL
• Threelevelsofinstantaneousalarm,plustime-weightedaveragealarms
on toxic gases
• Basestationcombinesfunctionalityofdatainterfaceandbatterycharging
• Eventandtimeddatalogging
Impact Pro kit includes sensors for CO, O2, H2S, and LEL; integral pump and pump adapter, charger with
charging base, rechargeable NiMH batteries, belt clip, ow adapter, 30' sample tube with inline adapter, ball oat,
base station PC link cable, software CD, quick-start guide, user manual, and carrying case.
Honeywell Impact Pro Multigas Monitor $40.00
Daily
$100.00
Weekly
$350.00
Monthly
$1304.00
to Buy
Honeywell Enforcer Calibrator for Impact Pro $15.00
Daily
$42.00
Weekly
$105.00
Monthly
$268.00
to Buy
• CalibratesHoneywellImpactPromultigasmonitorsttedwithoxygen,
ammable,carbonmonoxide,andhydrogensuldesensors
• RecordscalibrationresultsforprintingviaPCsoftware
• Built-inindicatortellsyouwhengascylinderneedsreplacing
• RecognizesImpactProimmediately,andcompletestestsandcalibration
in less than two minutes
Enforcer kit includes one multigas cylinder, wall-mount plate, and carrying case.
Choosing the Right Combustible Gas Detector for Your Application
Alarms Data Infrared Intrinsically Weekly
Product Visible Audible Vibrating STEL TWA Logging Port Safe Rental Price
HoneywellImpactPro 100.00
MSAAltair4 125.00
MSAOrion 100.00
MSASolaris 125.00
MSAPassportPIDII 250.00
MSASirius 350.00
866-RENT-EHS
(866)736-8347
Save
20% off the
listed purchase price
on all MSA portables
when you buy before
12/31/2008!
31
V 10.2008
Illinois, Indiana, and Iowa
Phone: 800-953-7626 • 630-595-8400
Fax: 630-595-2386
Wisconsin, and Upper Peninsula Michigan
Phone: 800-837-1700 • 262-923-1790
Fax: 262-923-1797
Lesman Instrument Company
www.lesman.com
sales@lesman.com
The new RAECO Rents instrumentation
catalog is now available! Get yours FREE!
COMBUSTIBLE
GAS MONITORS
Orion™ Multigas Detector for LEL, CO, O2, and H2S
• One-buttoncalibrationsimpliescalibration,reducestrainingneeds
• Largeeasy-to-readdisplayforlowlightconditionsandmanyangles
• Long-lifedurablesensorsprovideupto50timesthesiliconepoisontolerance
• Zoomexpandsanyportionofagraphtofocusonanactivitydetail
• Softwaretoviewgasessimultaneouslyorfocusononeatatime
• Resistanttowater/dust;Nyloncaseforuseintoughenvironments
• Long-lifebatteryprovidesupto20hoursinthenon-pumpmode
Orion kit includes pump module, sensors for %LEL pentane, O2, CO, and H2S, 10' sample line, 1' probe, NiMH battery
pack, battery charger and cord, screwdriver, lters, hose adapter, manual, FiveStar™ Link software, carrying case, orange
Cordura jacket, and integral PulseCheck pump.
$50.00
Daily
$100.00
Weekly
$350.00
Monthly
$2123.00
to Buy
Solaris Multigas Detector for Monitoring Combustible Gases
• 1-,2-,3-,and4-gascongurationsforO2,H2S,CO,andcombustibles
• 100+dBhorn,super-brightLED,andvibratingalarm
• Large,easy-to-readalphanumericdigitaldisplay
• Lightweightunit;IP65ratedforsuperiorprotectionagainstliquid/dustingress
• One-buttoncalibrationwithbuilt-inlogic
• LithiumIonbatterywithruntimeof14+hours
Kit includes detector, battery charger, charging station, calibration cap, tubing, two male ttings, infrared reader, Solaris
software, quick reference card and manual on CD.
$40.00
Daily
$125.00
Weekly
$300.00
Monthly
$1409.00
to Buy
Sirius Multigas Detector for VOCs and Combustible Gases
$100.00
Daily
$350.00
Weekly
$750.00
Monthly
$3617.00
to Buy
• OneunitsimultaneouslymonitorsVOCswithlowvaporpressuresandmeasures
forcombustible,toxic,andoxygen-decientatmospheres
• PIDsensorincludeshumidityresistance,stablezeroreadings,andfastresponse
and clear times
• MultidirectionalvisibleLEDalarmandaudiblehornalarm
• Displayshowscombustiblegas,CO,H2S,O2,%LEL,andVOCswiththeir
characternames,alsoincludesbatterylifeindicator
• Interchangeablebatterypackskeepinstrumentrunning24x7
Sirius kit includes PID lamp, 0-100% LEL, H2S, CO, and O2 sensors, power supply, AC adapter and battery charging unit,
sample line and probe, carrying case, orange Cordura jacket with harness, and instructions.
• 64pagesofinstrumentationforindustrialhygiene,safety,and
environmentalapplications
• Rentalsavailableonadaily,weekly,ormonthlybasis
• Allparts,accessories,andsoftwareavailable
• Automatic5%rentalfeediscountwhenyourentonlineatwww.raeco.com
Visit www.raeco.com to request a print catalog or download the free PDF.
Save
20% off the
listed purchase price
on all MSA portables
when you buy before
12/31/2008!
WE’RE WAITING!
When you need Honeywell Burner
Controls products fast, call Lesman.
We stock a wide variety of popular items
that can ship to you the same day.
135 Bernice Drive • Bensenville, IL 60106-3366
Order by phone, fax, or e-mail for fast, friendly service.
Prices are current as of publication date, and are subject to change without
notice. Visit www.lesman.com/catupdates.html for catalog updates.
Due to contractual agreements with our manufacturers, some items in
this catalog may not be available in all geographic areas or markets.
Use Our Hotlines! Bensenville IL Butler WI
Toll Free 800-953-7626 800-837-1700
Local Phone 630-595-8400 262-923-1790
Fax 630-595-2386 262-923-1797
E-Mail sales@lesman.com wisales@lesman.com
See More at
Lesman.com
• Fullspecsandmanualsonourburnerand
boiler controls product offering
• Lotsofarticles,technicaltips,and
application success stories
• Accesstopodcastsandvideotraining
• Allavailable24hoursaday,7daysaweek!
Need a Hand?
Our applications specialists are factory-trained to
help you through the installation and maintenance
headaches of typical flame safety systems.

Navigation menu