SWV3021W FOR 005

User Manual: SWV3021W

Open the PDF directly: View PDF PDF.
Page Count: 20

DownloadSWV3021W FOR-005
Open PDF In BrowserView PDF
Controlled Environment
Equipment Solutions
for the Lab

Forma® Cryopreservation Equipment

Analyze • Detect • Measure • Control™

Forma Cryopreservation Equipment

Features and Technical Specifications

Total
Cryogenic Solution
Indefinite Storage ... Infinite Possibilities
Your mission is to maintain cell viability at ultra-low temperatures. Thermo Electron
Corporation’s role is to help make that happen. You can depend on our complete line of
Forma Cryopreservation Equipment for improved viability and reliable long-term storage
for your valuable biological specimens. Controlled rate freezers, storage solutions that
vary by feature and capacity to suit every budget ranging from academic to biotech, a
range of inventory control systems and other accessories, and a staff of specialists to
answer your questions—it’s your Total Cryogenic Solution!

• Use our CryoMed® Freezers for controlled rate freezing. Then, use the CryoPlus® or Cryo Series for long-term LN2
storage. You will reap the rewards—reliability

for peace of mind, high performance

for safe sample freezing and storage, and ease of use.
• Rely on the CMR/CMC Series when portable LN2 storage is critical to your success in the lab. These containers
offer high

capacity for a wide range of applications and low LN2

consumption for cost-effective use.
• Transporting samples across town, across the country, or even across the world? Our CMD Series Dry Shippers are
an ideal choice. They combine temperature

stability for safe sample storage during

shipping, lightweight construction for easy handling, and ease of use.
We’ll also work as your partner to identify inventory control systems (e.g., racks, canisters, frames) for optimum
storage, external alarms for added security, lab dewars for easy LN2 transport, or other accessories that help you
take full advantage of your Forma Cryopreservation Equipment ... now and in the future.

2
TOTAL CRYOGENIC
SOLUTION
CryoMed Freezers . . . . . . . . . . . . .3
Accessories . . . . . . . . . . . . . . . . .7
CryoPlus & Cryo Series . . . . . . . .10
Accessories . . . . . . . . . . . . . . . .13
CMR/CMC Series . . . . . . . . . . . . .14
Accessories . . . . . . . . . . . . . . . .14
CMD Dry Shippers . . . . . . . . . . . .16
Accessories . . . . . . . . . . . . . . . .16
General Accessories . . . . . . . . . .17

The Goal of Cryopreservation
The objective of cryopreservation is to minimize
damage to biological materials, such as tissues,
mammalian cells, bacteria, fungi, plant cells,
and viruses, during low temperature freezing
and storage.
The ultimate goal is to provide a continuous
source of tissues and genetically stable living
cells for a variety of purposes, including research
and biomedical processes.

Cooling rate is known to have the most significant
influence on cell survival. A cooling rate too high
or too low can result in low cell recovery due to
dehydration or ice crystal formation. Controlled rate
freezing before long-term storage minimizes these
variables to ensure maximum viability for a wide
variety of cells.
Programmed, uniform cooling rates are effective
for a variety of freezing applications, including stem
cells, embryos, heart valves, and cord blood.

Why Choose LN2 Storage?
Why Is Controlled Rate Freezing Important?
Water, the major component of all living cells, must
be present for chemical reactions to occur within a
cell. During cryopreservation, the water changes to
ice and cellular metabolism ceases. Dehydration
also occurs, changing the concentration of salts
and other metabolites and creating an osmotic
imbalance that can be detrimental to cell recovery.
Detrimental effects of freezing biological materials can
be minimized by controlling the cooling rate, using
cryoprotective agents, maintaining appropriate
storage temperatures, and controlling the
rewarming rate.

CryoMed Freezers for Controlled Rate Freezing
Thermo’s CryoMed Freezers provide the ultimate
in controlled rate freezing flexibility. Three sizes
and two styles provide the freedom to choose a
controlled rate freezer that meets your specific
requirements.
• Freezers are a complete, one-piece system.
Control panel and thermal printer are integrated,
eliminating assembly and connection of electrical
components.
• Multiple freezing profiles can be modified to tailor
them to your specific protocols.

The temperature at which frozen cells are stored
affects their viability after recovery. The lower the
temperature, the longer the viable storage period.
At -196C (-320F), biologically relevant, thermallydriven chemical reactions are not known to occur.
It is, therefore, believed that the majority of the
population of stored cells will remain viable and
unchanged for an indefinite period.1

Learn More about Cryopreservation
Request the Cryopreservation Manual, A Guide to
Cryopreservation Techniques, or visit www.thermo.com.

• Computer enhanced CryoMed Freezer can be
created easily by adding a PC, installing our MS
Windows®-based Controlled Rate Freezing PC
Interface software (included), and connecting
an external inkjet printer.
Reliability for Peace of Mind
• Exterior has a powder coat paint finish for a high
quality appearance that resists scratches and chipping.
• Ergonomically designed door handle with vise
action latch is easy to grasp for front access to
your product. Several models also provide
convenient top access.

3
CRYOMED FREEZERS:
THREE SIZES,
TWO STYLES
• 0.6, 1.2, and 1.7 cu. ft. volume* chambers
with front access
• 0.6 and 1.2 cu. ft. volume chambers with
front and top access, designed for
human IVF use and easy “seeding”
(FDA 510(k) number K021042)
1. Committee on Germ Plasm Resources, Division of Biological Sciences, Assembly of
Life Sciences, National Research Council, 1978. Conservation of Germ Plasm Resources:
An Imperative. 7:79-84.

*Higher capacity custom sizes available

CryoMed Freezers

Features and Technical Specifications

Reliability for Peace of Mind (continued)

Ease of Use

• Quiet running units are constructed of Type
304 stainless steel for durability and long life.

• Specific models
designed for
human IVF use
(510(k) number
K021042)

• For added security, a modifiable access code
(instead of a key) prevents unwanted user profile
changes or freezing run interruptions.

– allow
convenient
top access
for manual
sample “seeding” applications

• If a power outage lasting less than 10 seconds
occurs, the freezer continues to operate without
interruption or alarm when power resumes. If the
outage lasts longer, the unit continues to operate
after power resumes, but an audible/visual alarm
occurs, and a message indicates the duration of
the power outage.

– include an external sample thermocouple that
can be placed in a position similar to that of
the remaining samples for a truer representation
of the entire product load

High Performance for Safe Sample Freezing
• Foamed-in-place polyurethane insulation
creates an improved R factor that minimizes
cabinet condensation, ensuring that there is
little moisture to wipe from your benchtop.

• Unique signature freezing graph illustrates
sample and chamber temperatures, and latent
heat of fusion, ensuring a documented process.
You can easily see the correlation between time
and sample/chamber temperature.

• Dual solenoid valves increase LN2 injection
volume, ensuring precise temperature control and
accelerated freezing for optimum cell viability.
• Specially designed air handling system and
unique liquid nitrogen injection ring (U.S. Patent
6,044,648) work together to ensure optimum
temperature control and uniformity.
– Horizontally directed, recirculating airflow
allows greater thermal heat/cooling transfer,
meeting the requirements of demanding protocols.
– LN2 ring provides a continuous nitrogen vapor
supply that ensures optimum, uniform product
cooling and prevents premature “seeding.”
• Heating element with overtemperature protection
balances controlled freezing and rewarming,
minimizing the risk of cell damage.

Chamber
Temp.

Sample
Temp.

Note:
Step 2 is
1C/minute until
the sample
temperature
reaches -4C

Latent
Heat of
Fusion

4
MAKE THE MOST
OF YOUR CRYOMED
FREEZER!
We offer a broad range of
accessories for your controlled
rate freezer, including quickrelease vial, straw and cane
holders; racks; presses; IQ/OQs;
and thermocouple sensors.

Reliable Teflon heat
breaks prevent the
door from freezing closed
High performance
bulb-style gaskets
ensure a tight door seal
Optional, easy-to-use,
quick-release style holders
for vial, straw, and cane
freezing prevent sample
warm-up caused by
handling. They eliminate
the need to touch the
sample during removal.

Easy-to-Program and Monitor
• Intuitive controls interface ensures that you
quickly accomplish new tasks.

• Pre-Cool step automatically starts the
temperature ramp when the chamber and
sample temperatures are equilibrated within
1C, eliminating the need for you to wait and
initiate the run.

• Six preset and ten user profiles are standard.
– Preset profiles reduce startup time by serving
as a starting point when your protocol
is unknown.
– Preset profiles can be copied and pasted
to create new profiles. These new profiles
can be edited and named to meet your
protocol requirements.
– Ten user profiles allow twenty steps each
for individual, user-created profiles.

ous
imultane
Unique, s
y!
la
p
re dis
temperatu

• Double beep indicates that the Hold time has
elapsed, alerting you to a critical time in the run
(i.e., “seeding”).
• Programmable chart resolution allows you to
define the temp/time scales, making it possible
to conserve chart paper.
• At-a-glance chamber and sample temperatures,
and operation status allow continuous monitoring
and also eliminate confusion about which
temperature is displayed.

Control Indicators – Show chamber cooling
and heating process
Cool: One LN2 solenoid open
Cool +: Both solenoids open

Status Indicators –

Heat: Chamber heater operating

Idle: No profile running
Audible/Visual Alarm

Run: Profile run in progress
Wait: Profile waiting
at set temp

Alarm Silence – Turns
off the audible alarm

End: Profile run finished
Warm: Chamber heating to
25C (77F), holds for 30
minutes

Chamber and Sample
Temperatures – Indicate tenth
of a degree C from -19.4C to
19.4C (-2.9F to 67F)

Main Display (backlit 4 line, 20
characters/line LCD) – Indicates
program status, including
alarm conditions

Programming Buttons –
Advance or reverse through
menus/sections, or modify
profile and unit setup
parameters

Warm – Starts the
warming cycle

Back – Terminates a
program in progress

Enter – Moves the cursor to the right in
the Main Display and activates the profile
view and edit modes

Run – Starts the selected
program and resumes the
program after a Wait mode

5

*Computer equipment is available from us, or you can use your own. Visit www.thermo.com and search for the CryoMed Freezers
product page for details about hardware and software requirements and available equipment.

CryoMed Freezers

Features and Technical Specifications

Easy-to-Create Computer Enhanced System
for a Broader Range of Features
Each CryoMed Freezer can be enhanced by adding an
IBM-compatible computer, installing our PC Interface
software (CD-ROM included with every freezer), and
connecting an external printer. Computer equipment
is available from us, or you can use your own.
Visit www.thermo.com and search for CryoMed
Freezers for details about hardware and software
requirements and available equipment.
A computer enhanced CryoMed Freezer provides
added features to your freezing system. You can capture
graphs and freezing profile and sample information.
All controlled rate freezing processes can be
completely monitored and controlled. For example,
you can create/edit freezing profiles; download
profiles to the freezer; monitor the progress of those
downloaded profiles; and analyze, export, print, and
save the profile data.

• Sample and chamber temperature, and operating
status are monitored once per second to ensure real
time/real temperature accuracy. Graphical data
analysis and display update once every six seconds.
Data is stored to the hard drive once per minute.
• Zoom functions make it easy to monitor the
controlled rate freeze. The graph can display
temperature ranges of 1C to 20C (33.8F to 68F)
per division and time ranges from 6 seconds to
20 minutes per division.
• Storing graphs on the computer hard drive or
diskettes eliminates storing chart paper.
• Twelve user-defined, programmable information fields
are available and saved with the Run data.
• Stored data can be exported to a commaseparated variable format, allowing data to be
imported into a spreadsheet.

PC Software Overview

Main Menu – Select a function such as Edit, Run,
Review, or Options; context-sensitive Help Screens
(F1) are available throughout the software

Options Screen – Select colors for on-screen and
color printout data, enter text labels (field names)
for printed reports, select default directories for
program and run data, and maintain user names
and case-sensitive passwords

Edit Screen – Create new temperature profile
programs, edit existing programs, select from a list of
available program steps (e.g., Wait, Ramp), repeat
portions of the program with Loop and Jump steps,
print program listings on an external printer, and add
comments that are saved with each profile program
for specimen preservation history

Run Screen – Select and run a temperature profile
program, monitor progress as the freezer operates,
use the manual override buttons during a run to add
heating or cooling, and print the run temperature
profile on an external printer

6

Review Screen (not shown) – Select a previous program
for review or analysis, compare two previous
programs, review data at a specific point, export data,
and print to a printer connected to the PC

CryoMed Freezer Specifications
Temperature
Range . . . . . . . . . . . . . . . . 50C to -180C
(122F to -292F)
Capacities & Models*
Front Access Units
0.6 Cu. Ft. (17.0 liters) . . Small: 7450 (7451, 7472)
1.2 Cu. Ft. (34.0 liters) . . Medium: 7452 (7453, 7473)
1.7 Cu. Ft. (48.1 liters) . . Large: 7454 (7455, 7474)
Front & Top Access IVF Units
0.6 Cu. Ft. (17.0 liters) . . Small: 7456 (7457, 7475)
1.2 Cu. Ft. (34.0 liters) . . Medium: 7458 (7459, 7476)
Exterior Dimensions
Width (0.6)** . . . . . . . . .
Width (1.2)** . . . . . . . . .
Width (1.7) . . . . . . . . . . .
Height (front access units).
Height (front & top . . . . .
access units)
F-B** . . . . . . . . . . . . . . .

. 20.4" (78.7cm)

Interior Dimensions
Width (0.6) . . . . . .
Width (1.2) . . . . . .
Width (1.7) . . . . . .
Height . . . . . . . . .
F-B . . . . . . . . . . . .

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

31.7"
37.7"
43.7"
21.2"
22.5"

(80.5cm)
(95.8cm)
(111.0cm)
(53.8cm)
(57.2cm)

7.0" (17.8cm)
13.0" (33.0cm)
19.0" (48.3cm)
12.0" (30.5cm)
13.0" (33.0cm)

Utility Connections
Connections . . . . . . . . . . . 1/2" 45 degree flare,
6.0 ft. (1.8 m) flexible,
stainless steel transfer
hose (included)
Electrical
7450/7452/7454/. . . . . . . . 120V, 60 Hz, 12.0 FLA
7456/7458
(Operating range
108-130V)
7451/7453/7455/. . . . . . . . 230V, 50/60 Hz,
7457/7459
5.5 FLA, (Operating
range 207-253V)
7472/7473/7474/. . . . . . . . 100V, 50/60 Hz,
7475/7476
10.5 FLA, (Operating
range 90-110V)
Plug . . . . . . . . . . . . . . . . . 120V & 100V:
NEMA 5-15P Plug
230V: CEE 7/7 Plug
Weight
Net
0.6 Cu. Ft. . . . .
1.2 Cu. Ft. . . . .
1.7 Cu. Ft. . . . .
Shipping (Motor)
0.6 Cu. Ft. . . . .
1.2 Cu. Ft. . . . .
1.7 Cu. Ft. . . . .

. . . . . . . 140 lbs. (63.5 kg)
. . . . . . . 160 lbs. (72.6 kg)
. . . . . . . 180 lbs. (81.6 kg)
. . . . . . . 200 lbs. (90.7 kg)
. . . . . . . 215 lbs. (97.5 kg)
. . . . . . . 235 lbs. (106.6 kg)

All units are UL Listed to United States and Canadian requirements and bear the CE Mark.
*All units include a 2.0ml sample thermocouple sensor, thermal paper, Controlled Rate Freezing PC software
CD-ROM and manual, 25 pin to 9 pin serial interface cable/adapter, and 10 ft. (3.0 m) RS-232 cable.
**Width includes the vent. Add 2.8" (7.1cm) to the F-B dimension for the door handle and LN2 injection fittings.

Accessories for CryoMed Freezers

IQ/OQ Protocols

We offer a full line of accessories to complement
your cryopreservation equipment, allowing you to
make the most efficient use of each CryoMed
Freezer’s chamber space.

IQ/OQ includes MS-Windows-compatible document
disk for process customization and fully detailed
checklists to qualify unit setup and operation.

This section describes the most common
accessories used with our controlled rate freezers.

IQ/OQ Kits that include all items needed to perform
the uniformity portion of the IQ/OQ are also
available. Contact us for details.

Refer to the General Accessories section for items
such as a thermal data printer, waterproof gloves,
aprons, markers, and vials, etc.

Stock No.
6007452
6007456

Description
IQ/OQ for front access units
IQ/OQ for top and front access units

7

CryoMed Freezers

Features and Technical Specifications

Accessories for CryoMed Freezers (continued)
ple
t sam handling!
n
e
v
e
Pr
ed by
al,
caus elease vi
p
u
rs
warm ur quick-r
holde
Try o and straw s.
t
,
cane or IVF uni
f

3

6a

2

5a
4

1

6b

5b
16

15

11

12

7
8

14

10
13

9

Racks and Holders

Description

Rack or Holder Capacity

4000294
4000303

4

8

12

162 canes, 5-6 ampules/cane

–

1

1

2

4000700

77 canes, 5-6 ampules/cane

1

–

1

4 straws

18

30

–

1 vial
Six 1.2ml vials or five 2.0ml vials
–
76 ampules/rack

18

30

–

18
18
5

30
30
–

–
–
5

5 racks, 76 ampules/rack
161 ampules/rack

1
–

–
5

1
5

4000705
4000706

0.25/0.5ml Straw Rack
Cane Freezing Rack, shown with
optional canes (1 cane = No. 4000211)
Cane Freezing Rack, shown with
optional canes (1 cane = No. 4000211)
Only for IVF models (front and top access)
0.25/0.5ml Straw Holder
1.2/2.0ml Vial Holder, includes a 1.2ml
and a 2.0ml vial for a sample probe
1.2/2.0ml Cane Holder
Sleeve Plug
1.2/2.0ml Cryo Rack
1.2/2.0ml Cryo Rack Holder, shown
with 5 optional racks (1 rack =
No. 4000701)
1.2/2.0ml Cryo Rack
1.2/2.0ml Cryo Rack Holder, shown
with 5 optional racks (1 rack =
No. 4000703)
4.0/5.0ml Cryo Rack
4.0/5.0ml Cryo Rack Holder

40 straws/rack

3

–
3

1
6

1
9

4000707
4000708

4.0/5.0ml Cryo Rack
4.0/5.0ml Cryo Rack Holder

1
–

–
3

1
3

4000308
4000310

HLA Tray Rack
2 Level Skin Rack

–
–

1
1

1
1

1

2

3

4000312

1 Level Skin Rack

5 racks, 161 ampules/rack
76 ampules/rack
Three 4.0/5.0ml Cryo Racks,
76 ampules/rack
161 ampules/rack
Three 4.0/5.0ml Cryo Racks,
161 ampules/rack
156 trays
48 skin packets, 5.0" x 7.0"
(12.7cm x 17.8cm) and
4.0" x 6.0" (10.2cm x 15.2cm)
24 skin packets, 5.0" x 7.0"
(12.7cm x 17.8cm)

2

4

6

4000710
4000711
4000714
180255
5a 4000701
5b 4000702

8

Max. Quantity Per Chamber
0.6 Cu. Ft. 1.2 Cu. Ft. 1.7 Cu. Ft.

Stock No.

6a 4000703
6b 4000704

1

Bag Freezing Presses

Stock No.
16 4000314
4000316
4000317
14 4000318
4000320
4000321
4 4000340
12 4000555

Max. Quantity Per Chamber
0.6 Cu. Ft. 1.2 Cu. Ft. 1.7 Cu. Ft.

Description

Press Capacity

Nexell R4R9953 (Fenwal 4R5461)
Gambro DF-200
Delmed 2030-2
Nexell (Fenwal 4R5461)
Gambro DF-200
Gambro DF-700
Cord Blood Freezer Rack, shown with
optional swing arm canister No. 4000610
Fenwal 4R5462

2 bags/press
2 bags/press
4 bags/press
Double, 4 bags/press
4 bags/press
2 bags/press

4
–
–
–
–
–

8
4
4
4
4
4

16
8
8
4
8
8

10 place
2 bags/press

3
4

6
8

9
12

Sample Thermocouple Sensors

Stock No. Description*
4000381
4000382
4000383
4000384
15 4000385
7 4000386
13 4000393
4000402
4000403

Thermocouple Sensor, 1.2/2.0ml Cryo Tube
Thermocouple Sensor, 4.0/5.0ml Cryo Tube
Thermocouple Sensor, 0.25/0.5ml Straw
Thermocouple Sensor, 0.25/0.5ml Straw
Thermocouple Sensor, 1.2/2.0ml Cryo Tube
Thermocouple Sensor, 4.0/5.0ml Cryo Tube
Thermocouple Sensor, Ribbon Type for Bags
Thermocouple Sensor, 0.020 Sheath, Straw Sample
Thermocouple Sensor, 0.062 Sheath, Vial Sample

0.6 Cu. Ft.

1.2 Cu. Ft.

1.7 Cu. Ft.

•
•
•
•
•
•

•
•
•
•

•
•
•

•
•

*All sensors are provided with a male plug.

Additional Accessories

Stock No. Description

9
11
10
8

4000211
4000610
4000221
4000388
4000226
189446
820010
820011
820013
820014

One cane
Fenwal 4R9951 Swing Arm Canister
Cryo Marker Pens, set of 4 pens (black,blue, green, red)
Cryo Tongs
Cryo Vial Filling Rack (holds 50)
Elbow-Length Cryo Gloves (size large)
2.0" (5.1cm) High Polycarbonate Box with 100-Cell Divider, includes a numerical grid system printed on the cover
2.0" (5.1cm) High Polycarbonate Box with 81-Cell Divider, includes a numerical grid system printed on the cover
3.0" (7.6cm) High Polycarbonate Box with 81-Cell Divider, includes a numerical grid system printed on the cover
3.8" (9.5cm) High Polycarbonate Box with 81-Cell Divider, includes a numerical grid system printed on the cover

9

CryoPlus and Cryo Series LN2 Storage Systems

Features and Technical Specifications

CryoPlus and Cryo Series for Long-Term Storage

High Performance for Safe Sample Storage

CryoPlus and Cryo LN2 Storage Systems provide the
ideal combination of liquid nitrogen storage reliability
and microprocessor technology. Both series feature
an auto-filling system. The primary difference is in
the controls.

• LN2 storage tanks are vacuum insulated with a
stainless steel chamber to minimize the risk of
condensation and ensure optimum temperature for
safe product storage.

Four sizes, including a unique 24.0" (61.0cm)
diameter unit, provide the proper size needed
while minimizing your LN2 storage costs.
Reliability for Peace of Mind
• Exterior cabinet is constructed of 18 gauge,
cold-rolled steel with powder coated paint for
durability and a high quality, uniform finish that
resists chipping and rust.
• Liquid level sensor and fill port are located within
the vacuum space, ensuring maximum storage area
and protection of the sensor from damage that could
be caused during inventory rack movement.
• Digitally displayed under-the-lid temperature
(CryoPlus Series only) notifies you of high
temperature conditions by indicating the
highest temperature reading inside the tank.

• Lid incorporates
foamed-in-place,
high density
polyurethane
insulation with
a dedicated
vent (U.S. Patent
5,779,089) to
prevent ice build
up and provide
added user safety.
• Two independent, flexible gaskets around the lid
opening reduce moisture migration into the chamber,
eliminating ice build up so the lid functions properly.
• Temperature sleeve included with CryoPlus (optional
for Cryo Series) provides colder temperatures and
more efficient vapor phase operation.
Ease of Use
• Low tank profile and patented counterbalanced lid
(U.S. Patent 5,779,089) with 100% clearance
allow easy access and sample retrieval.

• Microprocessor controls on CryoPlus Series
allow precise and accurate control over all 16
parameters without complicated programming.
Cryo Series controls feature audible/visual
alarms so you can easily check performance.

• Heavy-duty casters provide mobility within the lab.

• Unique 24 tri-color LEDs on CryoPlus Series
continuously display the actual liquid nitrogen
level and high level/low level setpoints so you
know the system’s status and any level alarm
conditions at all times.

• Optional racks, canisters, frames, and risers allow
you to create an organized inventory system that
meets your specific needs and provides optimum
storage in liquid or vapor phase. Custom inventory
systems are available. Contact us for details.

• All units include alarm contacts for remote
monitoring of storage tank conditions.

10
CRYOPLUS & CRYO:
FOUR SIZES, RANGE
OF CAPACITIES
• 16.0", unique 24.0", 31.0", and
39.5" diameter sizes
• 6,318, 13,000, 24,000, and
38,500 vial (2.0ml) capacities

Easy-to-Program and Monitor – CryoPlus Series
Top-mounted control panel on CryoPlus Series ensures convenient access to the microprocessor controller for
easy programming via the touchpad. These controls provide 16 audible/visual alarms and include a digital
temperature display.

Temperature – Indicates actual temp under
the lid and high temp alarm setpoint

Fill Valve Open – Indicates solenoid valve is open

Status Indicators & Visual Warnings –
Level Sensor: Level sensor malfunction
Fill Valve: Fill solenoid valve malfunction
LN2 Source: Insufficient LN2
By-Pass Sensor: Malfunction or
disconnection of by-pass sensor
(with gas by-pass option)

Alarm Silence

By-Pass Valve: Solenoid valve malfunction
(with gas by-pass option)

Programming Touchpad – Incorporates
eight functions for selecting/operating
all control features

Lock – Twoposition switch
allows access
to all controller
functions

Open Valve: Fill solenoid valve stuck open

ue to
Uniq mo!
Ther

24 Tri-Color LEDs – Continuously display
actual LN2 level, high level/low level
setpoints, and alarm conditions for at-a-glance
monitoring of all parameters

Yellow: Remaining space above the high level flashing
indicator. Flashing yellow upper section indicates the stop
fill and high level alarm setpoints. Lower section indicates
the start fill and low level alarm setpoint.

Select Scale – Indicates which
phase scale is in use; low and high
factory preset levels are 3.0"
(7.6cm) and 5.0" (12.7cm),
respectively
Liquid Phase: 2.0" to 25.0" (5.1cm
to 63.5cm)
Vapor Phase: 1.5" to 7.25" (3.8cm
to 18.4cm)

Green: Actual LN2 level
Red: LN2 high or low level alarm conditions

Easy-to-Monitor – Cryo Series
Front-mounted control panel on Cryo Series provides audible/visual alarms so you can easily check unit
performance. Access plate at the top of the unit makes it easy to adjust the liquid level sensor.

Choice of manual fill or built-in automatic liquid
level control system to the following factory
preset levels:
Low: 3.0" (7.6cm)
High: 5.0" (12.7cm)

Audible/VIsual Alarm

Alarm Silence

11

CryoPlus and Cryo Series LN2 Storage Systems

Features and Technical Specifications

CryoPlus and Cryo Series Specifications
Tank Diameters & Models
16.0" (40.6cm)
CryoPlus 1. . . . . . . . .
Cryo 100 . . . . . . . . . .
24.0" (61.0cm)
CryoPlus 2. . . . . . . . .
Cryo 200 . . . . . . . . . .
31.0" (78.7cm)
CryoPlus 3. . . . . . . . .
Cryo 300 . . . . . . . . . .
39.5" (100.3cm)
CryoPlus 4. . . . . . . . .
Cryo 400 . . . . . . . . . .
Interior Height (All) . . . .
LN2 Capacity
16.0" . . . . . .
24.0" . . . . . .
31.0" . . . . . .
39.5" . . . . . .

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

. . 7402 (7403)
. . 742 (743)
. . 7404 (7405)
. . 744 (745)
. . 7406 (7407)
. . 746 (747)
. . 27.5" (69.9cm)

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

90 Liters
200 Liters
340 Liters
552 Liters

Static Evaporation Rate*
16.0" . . . . . . . . . . . . . .
24.0" . . . . . . . . . . . . . .
31.0" . . . . . . . . . . . . . .
39.5" . . . . . . . . . . . . . .

.
.
.
.

.
.
.
.

.
.
.
.

3 Liters/Day
5 Liters/Day
8 Liters/Day
10 Liters/Day

Static Holding Time
16.0" (40.6cm). . . .
24.0" (61.0cm). . . .
31.0" (78.7cm). . . .
39.5" (100.3cm). . .

.
.
.
.

.
.
.
.

.
.
.
.

30 Days
40 Days
42.5 Days
55 Days

Exterior Dimensions
Width (16.0") . . . . . . . . . .
Width (24.0") . . . . . . . . . .
Width (31.0") . . . . . . . . . .
Width (39.5") . . . . . . . . . .
Height (16.0", 24.0", 31.0").
Height (39.5")**. . . . . . . .
F-B (16.0") . . . . . . . . . . . .
F-B (24.0") . . . . . . . . . . . .
F-B (31.0") . . . . . . . . . . . .
F-B (39.5") . . . . . . . . . . . .

.
.
.
.
.
.
.
.
.
.

21.5"
28.5"
34.5"
43.5"
41.0"
47.0"
26.0"
34.0"
41.5"
50.0"

.
.
.
.

.
.
.
.

. . 7400 (7401)
. . 740 (741)

.
.
.
.

.
.
.
.

(54.6cm)
(72.4cm)
(87.6cm)
(110.5cm)
(104.1cm)
(119.4cm)
(66.0cm)
(86.4cm)
(105.4cm)
(127.0cm)

Clearance Requirements
F-B . . . . . . . . . . . . . . . . . . Add 5.0" (12.7cm) to F-B
for utilities and lid
opening

12

Maximum Capacity (2.0ml Vial Size)
16.0" . . . . . . . . . . . . . . . . . 6 No. 4000044
arrowhead racks,
6,318 vials;
11 No. 4000012 vertical
racks, 5,500 vials
24.0" . . . . . . . . . . . . . . . . . 10 No. 4000006 square
racks, 13,000 vials;
26 No. 4000012 vertical
racks, 13,000 vials
31.0" . . . . . . . . . . . . . . . . . 17 No. 4000006 square
racks, 22,100 vials;
48 No. 4000012 vertical
racks, 24,000 vials
39.5" . . . . . . . . . . . . . . . . . 28 No. 4000006 square
racks, 36,400 vials;
77 No. 4000012 vertical
racks, 38,500 vials
Electrical
7400/7402/7404/7406/ . . . 100-120V, 50/60 Hz,
740/742/744/746
0.8 FLA (Operating
range 90-132V)
7401/7403/7405/7407/ . . . 200-230V, 50/60 Hz,
741/743/745/747
0.5 FLA, (Operating
range 180-253V)
Plug . . . . . . . . . . . . . . . . . 100-120V: NEMA 5-15P
Plug
200-230V: CEE 7/7 Plug
Utility Connection
All Models . . . . . . . . . . . . 1/2" 45 degree flare,
4.0 ft. (1.2 m) flexible,
hose included for
Models 7400 (7401) and
740 (741); 6.0 ft. (1.8 m)
hose for all other models
Weight
Empty
16.0" . . . . . . . .
24.0" . . . . . . . .
31.0" . . . . . . . .
39.5" . . . . . . . .
Full
16.0" . . . . . . . .
24.0" . . . . . . . .
31.0" . . . . . . . .
39.5" . . . . . . . .
Shipping (Motor)
16.0" . . . . . . . .
24.0" . . . . . . . .
31.0" . . . . . . . .
39.5" . . . . . . . .

All units are UL Listed to United States and Canadian requirements and bear the CE Mark.
*Rate is based on new container performance. Actual performance may vary with
individual applications. Excludes supply tank evaporation rate.
**39.5" tank has a total height of 93.5" (237.5cm) with the lid open.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

214
325
416
820

lbs.
lbs.
lbs.
lbs.

(97.1 kg)
(147.4 kg)
(188.7 kg)
(371.9 kg)

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

354 lbs. (160.6 kg)
680 lbs. (308.4 kg)
1,021 lbs. (463.1 kg)
1,620 lbs. (734.8 kg)

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

260 lbs. (117.9 kg)
480 lbs. (217.7 kg)
550 lbs. (249.5 kg)
1,070 lbs. (485.3 kg)

Accessories for CryoPlus and Cryo Series

IQ/OQ Protocols

Accessories designed specifically for the CryoPlus
and Cryo Series are listed here. All accessories are
customer installed unless noted otherwise. Refer to the
General Accessories section for additional items,
such as a thermal data printer, waterproof gloves,
vials, and canes.

Stock No.
6007400
6000740

Description
6.0", 7 day temperature recorder, pen,
and chart drive (specify top, left side, or
right side mount)

Sensaphone® Telephone Dialing Systems
Stock No.

400047
400134
400142

Inventory Control Systems
Organize your biological specimens with our line of
inventory control systems.

Recorder Kit
Stock No.
201175

Description
IQ/OQ for the CryoPlus Series
IQ/OQ for the Cryo Series

Description
Sensaphone Telephone Dialing Systems,
continuously dial pre-programmed numbers
in sequence until one user is reached –
For up to four input channels
For up to eight input channels
RJ-11 Remote Alarm Cable Kit, used
to connect remote alarm contacts of
equipment, such as a Sensaphone
Telephone Dialing System

Racks and Risers
Inventory systems are available in vapor or liquid
phase capacities for 2.0ml, 4.0ml, or 5.0ml samples.
Vertical racks, which allow you to work conveniently
in the vapor or liquid phase, are available in 4 or 5
box configurations, each with 100-cell dividers.
Conventional square and arrowhead racks with 11 to
13 boxes are also available. All racks are shipped
complete with boxes, dividers, and locking rods. Risers
are available for vapor phase storage.

Examples of inventory racks,
boxes, and other accessories are shown
and identified on page 17.

Gas By-Pass Temperature Controllers
Canisters, Frames, and Risers
Stock No.

195021
195023
195700
195701

Description
Gas By-Pass Temperature Controllers,
divert warm nitrogen to atmosphere until
control probe senses LN2 in the line –
120V, factory installed
230V, factory installed
120V, must be installed by
qualified personnel
230V, must be installed by
qualified personnel

Our standard size canister/frame systems are ideal when
you are storing blood, blood components, or bone
marrow. These inventory systems maximize capacity
and protect your samples’ integrity. Durable
stainless steel frames coupled with lightweight
aluminum canisters protect your samples throughout
inventory retrieval processes.
Riser selection for commonly used racks and frames
is described below.

Choosing a Riser for Commonly Used Frames and Racks

For This Tank

and This Frame

or This Rack

Use Riser

Riser Height

16.0" CryoPlus 1/Cryo 100

–
4000660
4000371, 4000372
4000660
–
4000371, 4000372
4000660
–
–
4000660
–

4000106, 4000110
4000011, 4000106, 4000108
4000001
4000005
4000003, 4000011
4000001
4000005
4000003, 4000011
4000001
4000005
4000003, 4000011

4000060
4000056
4000060
4000062
4000061
4000063
4000065
4000064
4000066
4000068
4000067

3.5" (8.9cm)
4.0" (10.2cm)
3.5" (8.9cm)
4.0" (10.2cm)
5.0" (12.7cm)
3.5" (8.9cm)
4.0" (10.2cm)
5.0" (12.7cm)
3.5" (8.9cm)
4.0" (10.2cm)
5.0" (12.7cm)

24.0" CryoPlus 2/Cryo 200

31.0" CryoPlus 3/Cryo 300

39.5" Cryoplus 4/Cryo 400

Want to know more about our inventory systems and how you can maximize your storage capacity?
Visit www.thermo.com and locate the cryopreservation products, or give us a call!

13

CMR/CMC Series Portable LN2 Storage Containers

Features and Technical Specifications

CMR/CMC Series for Portable Storage

Accessories for the CMR/CMC Series

Choose our CMR/CMC Series when you require
the utmost portability in the lab. Maximum storage
capacity combined with minimum LN2 consumption
makes these the most cost-effective units available.

Accessories designed specifically for the CMR/CMC
Series are listed here. Accessories are customer
installed unless noted otherwise. Refer to the General
Accessories section for additional items, such as
the universal roller base for easy mobility,
waterproof gloves, vials, and canes.

High Capacity for a Wide Range of Applications
Multiple-sized CMR/CMC Series LN2 Storage
Containers are available in a variety of capacities
and are ideal for many sample sizes, including
2.0ml, 4.0ml, and 5.0ml vials.

Low Level Alarms (with Sensor)

• Container capacities range from 20.5 to 110.0 liters.
Rack or canister storage ranges from 180 to 3,564
vials (2.0ml).

4000576
4000575

• CMR containers include racks. CMC containers
include canisters.

Stock No.
4000574

4000577
8130

Vial Racks and Canister

4000556
4000557
4000558

4000559
• Color-coded/numbered inventory racking systems
are included to help reduce the risk of misplacing
specimens. A lockable clasp (lock not included)
provides specimen security.
Low LN2 Consumption for Cost Effective Use
The unique container design achieves long-term
storage and provides easy sample retrieval.
Our CMR/CMC Series storage containers are
constructed of durable, lightweight aluminum
with vacuum insulation that minimizes LN2
consumption while maximizing capacity.

14

Description
For Model 8033, 18.0" (45.7cm) sensor,
115V, factory installed
Same as No. 4000574 but 230V
For Models 8030 and 8031, 27.0"
(68.6cm) sensor, 115V, factory installed
Same as No. 4000575 but 230V
For any standard-size LN2 container,
includes dry contacts for connection
to a telephone dialing system or
remote alarm

4000561

4000562

Vial Racks for Model 8030
5.0ml Vial Rack, includes five 3.8"
(9.5cm) boxes with 100-cell dividers
4.0ml Vial Rack, includes six 3.0"
(7.6cm) boxes with 100-cell dividers
2.0ml Vial Rack, includes nine 2.0"
(5.1cm) boxes with 100-cell dividers
Vial Racks for Model 8031
5.0ml Vial Rack, includes five 3.0"
(7.6cm) boxes with 100-cell dividers
2.0ml Vial Rack, includes nine 2.0"
(5.1cm) boxes with 40-cell dividers
Canister for Model 8033

CMR/CMC Series Specifications
LN2 Capacities and Models
CMR Series
110.0 Liters . . . . . . . . .
CMC Series
20.5 Liters . . . . . . . . . .
33.4 Liters . . . . . . . . . .
47.4 Liters . . . . . . . . . .
79.0 Liters . . . . . . . . . .

. 8030/8031
.
.
.
.

8036
8037
8038
8033

Static Evaporation Rate*
8030 . . . . . . . . . . . . . . . . . 0.7 Liter/Day
8031/8038/8033 . . . . . . . . 0.4 Liter/Day
8036/8037. . . . . . . . . . . . . 0.1 Liter/Day
Static Holding Time
8030 . . . . . . . . . . .
8031 . . . . . . . . . . .
8036 . . . . . . . . . . .
8037 . . . . . . . . . . .
8038 . . . . . . . . . . .
8033 . . . . . . . . . . .
Dimensions
Diameter
8030/8031/8033 .
8036 . . . . . . . . .
8037 . . . . . . . . .
8038 . . . . . . . . .
Height
8030/8031 . . . . .
8036 . . . . . . . . .
8037 . . . . . . . . .
8038 . . . . . . . . .
8033 . . . . . . . . .
Neck Diameter
8030 . . . . . . . . .
8031/8033 . . . . .
8036/8037 . . . . .
8038 . . . . . . . . .

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

169
275
186
303
121
196

Days
Days
Days
Days
Days
Days

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

22.0" (55.9cm)
14.5" (36.8cm)
18.2" (46.2cm)
20.0" (50.8cm)

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

37.1" (94.2cm)
25.7" (65.3cm)
25.9" (65.8cm)
26,5" (67.3cm)
29.5" (74.9cm)

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

8.5" (21.6cm)
6.0" (15.2cm)
2.0" (5.1cm)
5.0" (12.7cm)

Racks with Boxes – Included with CMR Series
Number of Racks & . . . . . 8030: 4 racks,
Rack Size
5.5" x 5.5"
(14.0cm x 14.0cm)
8031: 8 racks,
3.3" x 5.0"
(8.4cm x 12.7cm)

Canisters – Included with CMC Series
Number of Canisters & . . . 8036/8037: 6 canisters,
Canister Diameter
1.5" (3.8cm)
8038: 6 canisters,
4.0" (10.2cm)
8033: 8 canisters,
4.8" (12.2cm)
Vial Capacity – 6 Vials (2.0ml)/Cane
2.0ml . . . . . . . . . . . . . . . . 8030: 3,564
8031: 2,808
8036/8037: 180
8038: 1,512**
8033: 2,880
4.0ml . . . . . . . . . . . . . . . . 8030: 2,376
8031: 1,872
8036/8037: 90
8038: 756
8033: 1,440
5.0ml . . . . . . . . . . . . . . . . 8030: 1,980
8031: 1,560
8036/8037: 60
8038: 504
8033: 960
Straw Capacity – 10/Cane (CMC Series Only)
Straws . . . . . . . . . . . . . . . 8036/8037: 540
8038: 4,500
8033: 5,000
Weight
Empty
8030/8031 . . . .
8036 . . . . . . . .
8037 . . . . . . . .
8038 . . . . . . . .
8033 . . . . . . . .
Full
8030/8031 . . . .
8036 . . . . . . . .
8037 . . . . . . . .
8038 . . . . . . . .
8033 . . . . . . . .
Shipping (Motor)
8030 . . . . . . . .
8031 . . . . . . . .
8036 . . . . . . . .
8037 . . . . . . . .
8038 . . . . . . . .
8033 . . . . . . . .

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

60
26
34
36
52

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

255 lbs. (115.8 kg)
63 lbs. (28.2 kg)
94 lbs. (42.7 kg)
120 lbs. (54.5 kg)
192 lbs. (87.2 kg)

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

130 lbs. (27.2 kg)
114 lbs. (51.7 kg)
28 lbs. (12.7 kg)
38 lbs. (17.2 kg)
46 lbs. (20.9 kg)
95 lbs. (43.1 kg)

*Rate is based on new container performance. Actual performance may vary with individual applications.
**Optional Square Rack Kit (No. 195749) for Model 8038 holds 750 vials (2.0ml).

lbs.
lbs.
lbs.
lbs.
lbs.

(27.2
(11.8
(15.4
(16.3
(23.6

kg)
kg)
kg)
kg)
kg)

15

CMD Series Dry Shippers

Features and Technical Specifications

CMD Series for Safe
Sample Transport
Available in three sizes,
CMD Series Dry Shippers
have capacities ranging
from 9 to 966 vials (2.0ml).

Temperature Stability for Safe
Sample Storage During Shipping
• Interior is lined with an absorbent material that
allows the samples to be transported in a dry
vapor condition, eliminating the risk of LN2 spillage
and injury of those handling the shipper.
• CMD Series containers can retain temperatures as
low as -190C (-310F). All models provide long holding
times for reliable, worldwide shipping convenience.
Lightweight Construction for Easy Handling
Our dry shippers have handles, are constructed
of lightweight aluminum, and are vacuum insulated
to ensure easy handling and temperature stability for
safe sample storage.
Ease of Use
• Easy-to-grasp handle
provides a comfortable grip.
• Lockable clasp (lock not
included) provides
product security.
• Models 8039 and 8040 include canisters.
These two models provide easy transfer
of small quantities of 2.0ml vials.
• Model 8032 includes a cardboard shipping
container (No. 4000073) and is a convenient
method of transporting bone marrow, heart valves,
and oversized samples.

Accessories for the CMD Series
Stock No.
189705

16
195460

Description
Hard Shell
Shipping
Container for
Models 8039
and 8040
Hard Shell
Shipping
Container for
Model 8032

CMD Series Specifications
LN2 Capacities and Models
1.6 Liters . . . . . . . . . . . . . 8039
4.3 Liters . . . . . . . . . . . . . 8040
10.0 Liters . . . . . . . . . . . . 8032
Static Evaporation Rate*
8039/8040 . . . . . . . . . . . . 0.1 Liter/Day
8032 . . . . . . . . . . . . . . . . . 0.7 Liter/Day
Static Holding Time*
8039 . . . . . . . . . . . . . . . . . 8 Days
8040 . . . . . . . . . . . . . . . . . 14 Days
8032 . . . . . . . . . . . . . . . . . 11 Days
Dimensions
Diameter
8039 . . . . . .
8040 . . . . . .
8032 . . . . . .
Height
8039 . . . . . .
8040 . . . . . .
8032 . . . . . .
Neck Diameter
8039 . . . . . .
8040 . . . . . .
8032 . . . . . .

. . . . . . . . . 7.3" (18.5cm)
. . . . . . . . . 8.7" (22.1cm)
. . . . . . . . . 15.0" (38.1cm)
. . . . . . . . . 13.5" (34.3cm)
. . . . . . . . . 19.4" (49.3cm)
. . . . . . . . . 23.0" (58.4cm)
. . . . . . . . . 1.4" (3.6cm)
. . . . . . . . . 2.0" (5.1cm)
. . . . . . . . . 8.5" (21.6cm)

Canisters** – Included for Models 8039 and 8040
Number of Canisters. . . . . 8039/8040: 1
Canister Diameter . . . . . . . 8039: 1.2" (3.1cm)
8040: 1.8" (4.6cm)
Vial Capacity
2.0ml . . . . . . . . . . . . . . . . 8039:
8040:
8032:
4.0ml . . . . . . . . . . . . . . . . 8039:
8040:
8032:
5.0ml . . . . . . . . . . . . . . . . 8039:
8040:
8032:

9
48
966
6
24
483
3
16
322

Straw Capacity
Straws . . . . . . . . . . . . . . . 8039: 15 (5/cane)
8040: 120 (10/cane)
8032: 1,610 (10/cane)
Weight
Empty
8039 . . . . . . . .
8040 . . . . . . . .
8032 . . . . . . . .
Full
8039 . . . . . . . .
8040 . . . . . . . .
8032 . . . . . . . .
Shipping (Motor)
8039 . . . . . . . .
8040 . . . . . . . .
8032 . . . . . . . .

. . . . . . . 6 lbs. (2.7 kg)
. . . . . . . 13 lbs. (5.9 kg)
. . . . . . . 30 lbs. (13.6 kg)
. . . . . . . 8.8 lbs. (4.0 kg)
. . . . . . . 20.6 lbs. (9.4 kg)
. . . . . . . 47 lbs. (21.3 kg)
. . . . . . . 9 lbs. (4.1 kg)
. . . . . . . 16 lbs. (7.3 kg)
. . . . . . . 41 lbs. (18.6 kg)

*Static evaporation rates and holding times are based on new container performance. Actual performance may vary with individual applications.
**Interior measures 8.5" diameter x 11.0" height (21.6cm x 27.9cm) storage capacity. Shipments of bone marrow, heart valves, or other
large samples require specific package size to determine the Model 8032 capacity.

General Accessories
This section describes many general accessories designed for your cryopreservation equipment. In addition,
this quick reference ID chart allows you to identify the most common accessories. Accessories are customer
installed unless noted otherwise.

7

5

4

8

12
10

3

2

11

9

6

1

13
18

23

24
25
27

22

14
16

21

28

Item
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

15

19

26
20

17

Stock No.

Description

189746
4000562
195555
4000561
4000556
4000112
4000007
4000006
4000260
4000011
4000012
4000379
4000176
4000218
4000371
189446
4000670
4000014
4000335
180143
4000238
4000013
4000193
4000189
4000174
4000221
4000060
4000389

Canister included with Models 8036 and 8037, 1.5" (3.8cm) diameter
Canister included with Model 8033, 5.0" (12.7cm) diameter
Square Inventory Rack for Model 8038 (optional), includes 2.75" (7.0cm) square boxes (No. 189470)
2.0ml Vial Rack for Model 8031, includes 2.0" (5.1cm) boxes (No. 4000189)
5.0ml Vial Rack for Model 8030, includes 3.0" (7.6cm) boxes (No. 4000015)
Jumbo Arrowhead Rack for CryoPlus 1 and Cryo 100, includes arrowhead boxes (No. 4000193)
Square Rack with Stainless Steel Boxes (13 boxes, each box (No. 4000238) is 2.0" (5.1cm) high)
Square Rack with Cardboard Boxes (13 boxes, each box is 2.0" (5.1cm) high)
Square Mini Vertical Rack, includes 2.75" (7.0cm) square boxes (No. 189470)
Vertical Rack (four box vapor phase rack), includes 2.0" (5.1cm) boxes (No. 4000014)
Vertical Rack (five box liquid phase rack), includes 2.0" (5.1cm) boxes (No. 4000014)
SUC-1 Square Rack, includes eight SUC-1 canisters
SUC-1 Canister (holds 16 canes with sleeves or 25 canes without sleeves, 10 straws/cane)
Cryo Sleeve (case of 100) with optional cane (No. 4000217)
Nexell R4R9953 (Fenwal 4R5461) 4 Place Frames with 4 optional Nexell sliding canisters (No. 4000335)
Elbow-Length Cryo Gloves (size large)
Nexell R4R9951 (Fenwal 4R9951) 7 place frame with 7 optional Nexell swing arm canisters
2.0" (5.1cm) Square White Box with Hole and 100-Cell Divider (included)
Nexell R4R9953 (Fenwal 4R5461) Sliding Canister and Delmed 8000/9000 Swing Arm Canister (No. 4000354)
LN2 Measuring Stick
2.0" (5.1cm) Square Stainless Steel Box with optional 100-cell divider (No. 4000013)
100-Cell Divider
2.0" (5.1cm) Jumbo Arrowhead Cardboard Box with optional 81-cell divider (No. 4000181)
2.0" (5.1cm) Rectangular Cardboard Box with optional 40-cell divider (No. 4000174)
40-Cell Divider
Cryo Marker Pens, set of 4 pens (black, blue, green, red)
3.5" (8.9cm) Riser
Cryo Tube Color Coding Caps (rainbow)

17

General Accessories

Features and Technical Specifications

Waterproof Cryo Gloves

Thermal Data Printer and Paper

Mid-Arm, 14.0" to 15.0" (35.6cm to 38.1cm)

This printer for CryoMed
Freezers and the CryoPlus
Series produces a hard
copy of operational
functions and alarm
sequences logged to
document system
performance (i.e., temperature,
time, date, liquid level, number of lid
openings/lid closings). A total of 16
alarms can be tracked and documented.

Stock No.
189441
189442
189443
189444

Description
Small
Medium
Large
Extra-Large

Elbow-Length, 18.0" to 20.0"
(45.7cm to 50.8cm)
Stock No.
189445
189446
189447

Description
Medium
Large
Extra-Large

Stock No.
4000565
4000665

Shoulder-Length, 28.0" (71.1cm)
4000566
Stock No.
189448
189449
189450

Description
Medium
Large
Extra-Large

Recorder Accessories
Stock No.
4000394

Canes

Stock No.
189451
189452
189453

4000395

4000396
4000397

Description
Small, 36.0"W (91.4cm)
Medium, 42.0"W (106.7cm)
Large, 48.0"W (121.9cm)

Description
Chart Paper for
Model 8028
(8029) and 8034
(8035) Recorder
(4 rolls/package)
Pen Kit for Model
8028 (8029) and
8034 (8035)
Recorder (5 pens/kit)
Chart Paper for Model 500 Bausch &
Lomb Recorder (4 rolls/package)
Pen Kit for Model 500 Bausch & Lomb
Recorder (4 pens/kit)

Cryo Marker Pens

18

Cryo Tube Color Coding Caps
Stock No.
4000230
4000231
4000232
4000233
4000234
4000235
4000236
4000237
4000389

Aprons

Stock No.
4000221

4000222
4000223
4000224
4000225

Description
Set of four fine tip pens—black, blue,
green, and red—with fast drying, nonsmearing, permanent ink; recommended
for all Cryogenic vials at -200C (-328F)
Black, set of 12
Blue, set of 12
Green, set of 12
Red, set of 12

Description
Printer, with cable assembly and RS-232
connector kit, 120V, 60 Hz
Same as No. 4000565 but with a 220V,
50 Hz AC adapter
Thermal Printer Paper (5 rolls/package)

Stock No.
4000211
4000214
4000216
4000217

Description
White, one case of 500
Red, one case of 500
Yellow, one case of 500
Green, one case of 500
Blue, one case of 500
Orange, one case of 500
Tan, one case of 500
Violet, one case of 500
Rainbow (assortment of all colors
above), one case of 400

Description
1.2ml – 6 Ampule
5.0ml – 2 Ampule
Aluminum Cane for 9.2ml and
10.0ml Goblets
Aluminum Cane for storage of all
12.5mm diameter Cryo tubes

Cryo Sleeve
Stock No.
4000218

Description
Cryo Sleeve, 0.6" (1.5cm) interior
diameter, 10.8" (27.4cm) long, case of
100 each

Cryogenic Vials
Each vial is constructed of sterile polypropylene with a white marking area and includes a screw cap.

Stock No.

Size

Description

Case Quantity

4000197
4000198
4000199
4000200
4000201
4000202
4000203
4000204
4000205
4000206
4000207
4000208

1.2ml
1.2ml
2.0ml
2.0ml
2.0ml
2.0ml
2.0ml
2.0ml
4.0ml
4.0ml
5.0ml
5.0ml

Self-standing, conical interior bottom, silicone washer
Self-standing, conical interior bottom, silicone washer
Self-standing, round interior bottom, silicone washer
Self-standing, round interior bottom, silicone washer
Round bottom, silicone washer
Round bottom, silicone washer
Self-standing, external threads
Self-standing, external threads
Round bottom, silicone washer
Round bottom, silicone washer
Round bottom, silicone washer
Round bottom, silicone washer

Vial Filling Rack

Tank Switchers*

Stock No.
4000226

Stock No.
8182

Description
Cryo Vial Filling Rack, holds 50
Cryogenic vials

LN2 Transfer Hoses and Phase Separator
4000272
Stock No.
4000400
4000401
4000571

Description
4.0 ft. (1.2m) Flexible Metal Hose, 1/2",
45 degree flare, swivel ends
6.0 ft. (1.8m) Flexible Metal Hose, 1/2",
45 degree flare, swivel ends
Phase Separator, 1.3" (3.3cm) diameter
x 3.0" (7.6cm) long x 1/4" FPT

4000273
4000274

Cane Canister, Tongs, and Low Level Alarm*
8185
Stock No.
4000176

4000388
8130

Description
SUC-1 Aluminum Cane Canister,
2.5" x 2.5" x 11.1" (6.4cm x 6.4cm x
28.2cm),16 holes/canister
Cryo Tongs
Low Level Alarm with Sensor for any
standard-sized LN2 container, includes
dry contacts for remote alarm

2,000
500
1,800
450
2,000
500
1,800
450
1,600
400
1,200
300

Description
Tank Switcher Control and Sensor,
No. 4000272 and No. 4000273 are
recommended when ordering
Model 8182
Solenoid Valve Assembly for
Model 8182, includes 100 psi valves,
relief valves, one-way check valve, and
TC fitting
Wall Mount Bracket for Model 8182 and
No. 4000272
Floor Stand for Model 8182 and
No. 4000272, 5.0 ft. (1.5m) high,
includes No. 4000273 wall mount
bracket
Interface Box for Model 8182 when
monitoring two or three level controls

Solenoid Valve and Valve Assembly
Stock No.
4000285
4000290

Description
Solenoid Valve, 1/4" NPT, 7/32" orifice,
100 psi
T-Valve Assembly with manual valve and
T fitting, used to connect two transfer
hoses to a supply tank
(continued)

19
2

3

ACCESSORIES

4

1

8

7
5

9
6
*115V, where applicable. Contact us for 230V options.

1. Model 8182 Tank Switcher
2. No. 4000273 Wall Mount Bracket for
Model 8182 and Solenoid Valve
Assembly (No. 4000272)
3. No. 4000272 Solenoid Valve Assembly
for Model 8182
4. No. 4000176 SUC-1 Cane Canister
5. No. 4000401 6.0 ft. Flexible Metal Hose
6. Model 8130 Low Level Alarm
with Sensor
7. No. 4000571 Phase Separator
8. No. 4000290 T-Valve Assembly
9. No. 4000388 Cryo Tongs

General Accessories, continued

Lab Dewars

Universal Roller Base

Lab dewars are handy containers that provide convenient
LN2 storage in the lab.

Stock No.
195230

Description
Fits 14.5" to 22.0" (36.8cm to 55.9cm)
diameter tanks, 325 lbs. (147.4 kg) capacity,
adds 3.6" (9.1cm) to the height

Stainless Steel LN2 Supply Tanks
All LN2 supply tanks are rated at 22 psi. Supply tank
evaporates 2% of its volume/day.
Stock No.
8126
8127
8120
8121

Model
LN2 Capacity (liters)
Static Evap. Rate (liters/day)
Neck Opening*
Overall Height*
Outside Diameter*

8122

8123

8124

8125

5.0
0.15
2.2/56
18.2/462
8.8/222

10.0
0.18
2.2/56
21.5/546
10.3/260

21.0
0.18
2.0/5.01
24.7/627
14.5/368

32.0
0.25
2.5/64.0
24.1/11
17/432

*Measurements are inches and millimeters (in/mm).

4000173

LN2 Withdrawal Devices
Stock No.
4000071

4000072

Description
LN2 Transfer Unit for Model 8124 only, supplied
with 2" (5.1cm) stopper and 19" (48.3cm)
stainless steel draw tube
LN2 Transfer Unit for Model 8125 only, supplied
with 2.5" (6.4cm) stopper and 20.5" (52.1cm)
stainless steel draw tube

4000175

Description
35 Liter Pressurized LN2 Supply Tank
50 Liter Pressurized LN2 Supply Tank
180 Liter Low Pressure LN2 Supply
Tank, 210 lbs. (95.3 kg) empty
230 Liter Low Pressure
LN2 Supply Tank with
caster base and
fold-down handle,
54.8" x 26.0"
(139.2cm x 66.0cm),
290 lbs. (131.5 kg),
dimensions are
27.0"W x 28.0"F-B
(68.6cm x 71.1cm)
at the caster base
LN2 Cylinder Hand Truck
with pneumatic wheels for use with
Model 8120
LN2 Cylinder Roller Base for use with Model
8120, base dimensions are 22.0"W x 3.5"H x
30.0"F-B (55.9cm x 8.9cm x 76.2cm)

About Thermo
A world leader in high-tech instruments, Thermo Electron
Corporation helps life science, laboratory, and industrial
customers advance scientific knowledge, enable drug
discovery, improve manufacturing processes, and protect
people and the environment with instruments, scientific
equipment, and integrated software solutions.

Based in Waltham, Massachusetts, Thermo Electron has
revenues of more than $2 billion, and employs
approximately 11,000 people in 30 countries worldwide.
For more information, visit www.thermo.com.

© 2004 Thermo Electron Corporation. All rights reserved. Sensaphone is a registered trademark of Phonetics Corporation. Windows is a registered trademark of Microsoft Corporation. All other trademarks and
registered trademarks are the property of Thermo Electron Corporation and its subsidiaries. Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your
local sales representative for details.
Rev. 0, 01/04 15M

Controlled Environment Equipment
P.O. Box 649 • Marietta, OH 45750
740-373-4763 • Fax: 740-373-6770
Toll Free USA and Canada 866-984-3766

www.thermo.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 20
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:03db7390-61cf-11da-be5d-000d93566a08
Producer                        : Acrobat Distiller 4.0 for Macintosh
Create Date                     : 2004:02:03 08:11:08Z
Modify Date                     : 2005:11:30 13:27:51-05:00
Metadata Date                   : 2005:11:30 13:27:51-05:00
Document ID                     : uuid:9306046d-7d6c-4b52-b5ba-b33fa22f1ce4
Instance ID                     : uuid:f0019a59-3c61-42e1-bea0-6dfe6dfefbda
Format                          : application/pdf
EXIF Metadata provided by EXIF.tools

Navigation menu