MDF U700VXC Panasonic Freezer Catalog
User Manual: MDF-U700VXC
Open the PDF directly: View PDF .
Page Count: 30
Download | |
Open PDF In Browser | View PDF |
Ultra-Low and Cryogenic Freezers VIP® Series | Twin Guard® Series PRO Series | Cryogenic | Chest www.panasonic.com/biomedical VIP® Series MDF-U76VC-PA -150°C Cryogenic Freezer MDF-C2156VANC-PA Twin Guard Series ® MDF-U700VXC-PA Give your samples the ultimate protection. The Industry’s Most Complete Ultra-Low Storage Solution. Offer your samples the advantage of first class cold storage technology with Panasonic ultra-low freezers. Our reputation is built on superior performance and reliability with uniform environment, even with higher ambient temperatures and frequent door openings. Panasonic ultra-low freezers meet the toughest quality standards for performance, ergonomics and ROI. We are proud to provide your samples with the ultimate and the most reliable protection, helping cutting-edge research in critical fields like medicine, life sciences, pharmaceuticals and biotechnology. Environmentally Friendly Technology Always a leader in environmentally friendly technology, Panasonic refrigerators use commercially available HFC refrigerants and CFC-free insulation. • Compliance of RoHS, Restriction of Hazardous Substance, on all units. • Panasonic is committed to developing green technologies that provide energy efficiency resulting in lower operational costs with less impact on the environment. Table of Contents 4 What to look for in an ULT freezer? 6 Find the right freezer for your needs. 8 Twin Guard® Freezers ( -86°C ) 15 VIP® Freezers ( -86°C ) 23 PRO Series Freezers ( -86°C ) 26 Cryogenic Freezer ( -150°C ) 28 Chest Freezers ( -80 / -86°C ) Panasonic Healthcare Company of North America What to look for in a freezer? 1. Reliability 2. Performance Panasonic products incorporate the latest applied theories and ideas, refrigeration compressors, electronic components, robotic manufacturing and economies-of-scale that directly benefit the customer. Furthermore, Panasonic products are extensively tested to meet the toughest quality standards in the world for performance, ergonomics and cost of ownership. Through the vigorous application of our unique Vertical Component Integration, Panasonic products offer tangible benefits - from performance and reliability to ergonomics and convenience -that no other manufacturer can provide. Panasonic Ultra low freezers offer the following advantages: • Rapid “pull down” – the time needed for your freezer to return to set point after door openings to maintain sample integrity • Best Temperature Uniformity that ensures all samples are well protected. Pulldown downspeed speed from room to -80°C Pull from room temptemp to -80°C Surpasses the customer preference of +/- 5°C* 30% Panasonic +5°C faster Brand A UNIFORMITY Based on internal validation data tested at -80°C setpoint, in an empty chamber with 23°C ambient temperature. Brand B 0 3 (Hours) 6 9 Twin Guard® Series ( -86°C ) -5°C MDF-U700VXC-PA VIP® Series ( -86°C ) MDF-U76VC-PA PRO Series ( -86°C ) MDF-U7486SC-PA 4 * The data may vary depending on the use, circumstances and optional accessories. Validation documents can be provided for each serial number with an additional fee. Ultra-Low and Cryogenic Freezers Panasonic ultra low freezers are insulated with high-performance CFC-free and HCFC-free insulation and new composite techniques to minimize energy consumption and lower operating costs. Beyond highly competitive first costs, Panasonic ultralow freezers demonstrate the lowest operating costs per cu.ft. (liter) in the worldwide market. 4.Footprint / Capacity Panasonic was the first company to introduce vacuum insulation panels to ultra-low temperature freezers. The Panasonic range of VIP® freezers typically provide 25% more storage capacity for a given floor area saving valuable laboratory space. Consumed Power (kWh / day) 3. Energy Efficiency 25 20 15 up to 31% more efficient 10 5 Panasonic Brand A Brand B The Panasonic patented VIP® vacuum insulation panel thin-wall composite is a high-efficiency design that yields more interior storage volume in a conventional freezer footprint. Superior Footprint Models: MDF-U700VXC, MDF-U500VXC, MDF-U76VA, MDF-U76VC, MDF-U56VC, MDF-U53VA, MDF-U33V. Stainless steel shelf and insulated inner-door combinations create choices of interior compartments that can be arranged for long-term, low access biologicals or shortterm, frequently accessed material. Cryogenic Freezer ( -150°C ) MDF-C2156VANC-PA Chest Freezers ( -80 / 86°C ) MDF-794C0-PA 5 Panasonic Healthcare Company of North America Find the right freezer for your needs. VIP® Series Freezers Twin Guard® Series Freezers Most reliable freezer with best performance and maximum energy savings. Two independent systems offering double security for your samples. Cryogenic Freezer Reliable mechanical refrigeration with maximum storage capacity. PRO Series Freezers Chest Freezers Energy efficiency and high performance cooling with space saving design. Optimum performance under optimum budget. Ultra-Low and Cryogenic Freezers Twin Guard® Series (-86ºC ) Insulation Type (2"/ 51 mm boxes) (3" / 76 mm boxes) (2ml vials in boxes) 8.37 sq.ft. 0.67 m2 VIP® PLUS 352 224 35,200 208/230V NEMA 6-15 9.51 sq.ft. 0.88 m2 VIP® PLUS 576 384 57,600 208/230V NEMA 6-15 Temperature Range Interior Volume Area Footprint MDF-U500VXC-PA -50ºC to -86ºC 18.3 cu.ft. 519 L MDF-U700VXC-PA -50ºC to -86ºC 25.7 cu.ft. 728 L Model Number (nominal) Storage VIP® Series (-86ºC ) Storage Storage Electrical, 60Hz Model Number Interior Volume Exterior Dimensions (w x f-b x h) Area Footprint, Nominal Insulation Type Fiberboard Boxes, 2” high (2ml) in Panasonic Racks Sample Vials, 2ml (2” box), 100-Cell Dividers Electrical, 60Hz MDF-U33V-PA 11.8 cu.ft. 333 L 26.4” x 34.1” x 73.2” 670 x 870 x 1860 mm 6.25 sq.ft. 0.58 m2 VIP® 216 21,600 115V, AC, 15 amp MDF-U53VA-PA 18.3 cu.ft. 519 L 30.3” x 34.4” x 78.3” 770 x 870 x 1990 mm 7.24 sq.ft. 0.67 m2 VIP® 352 35,200 115V, AC, 20 amp MDF-U56VC-PA 18.6 cu.ft. 526 L 30.3” x 34.4” x 78.3” 770 x 870 x 1990 mm 7.24 sq.ft. 0.67 m2 VIP® PLUS 384 38,400 208/230V, AC, 15 amp MDF-U76VC-PA 25.7 cu.ft. 728 L 39.8” x 34.4” x 78.3” 1010 x 870 x 1990 mm 9.51 sq.ft. 0.88 m2 VIP® PLUS 576 57,600 208/230V, AC, 15 amp MDF-U76VA-PA 25.7 cu.ft. 728 L 39.8” x 34.4” x 78.3” 1010 x 870 x 1990 mm 9.51 sq.ft. 0.88 m2 VIP® PLUS 576 57,600 115V, AC, 20 amp PRO Series (-86ºC ) Volume Exterior Dimensions MDF-U5486SC-PA 17.1 483 L MDF-U7486SC-PA 23.5 668 L Model Number (cu.ft.) Storage Storage Storage Voltage, Power Connection Insulation Type (2"/ 51 mm boxes) (3" / 76 mm boxes) (2ml vials in boxes) 35.0" x 34.4" x 78.3" 890 x 840 x 1990 mm Conventional 320 192 32,000 208/230V NEMA 6-15 44.5" x 34.4" x 78.3" 1130 x 870 x 1990 mm Conventional 480 288 48,660 208/230V NEMA 6-15 (w x f-b x h) Cryogenic Freezer ( -150ºC ) Model Number Volume Exterior Dimensions 8.2 231 L 68.1" x 30.1" x 39.8" 1730 x 765 x 1010 mm (cu.ft.) MDF-C2156VANC-PA (w x f-b x h) Storage Storage Storage Insulation Type (2"/ 51 mm boxes) (3" / 76 mm boxes) (2ml vials in boxes) VIP® PLUS 150 105 15,000 Voltage, Power Connection 208/230V NEMA 6-15 Chest Freezers (-86ºC / -80ºC ) Insulation Type Temperature (°C) (2"/ 51 mm boxes) (3" / 76 mm boxes) (2ml vials in boxes) 21.6" x 27.0" x 37.2" 550 x 685 x 945 mm VIP® PLUS -80°C 42 30 4,200 115V NEMA 5-15 17.2 487 L 79.1" x 30.3" x 42.1" 2010 x 770 x 1070 mm Conventional -86°C 351 243 35,100 208/230V NEMA 6-15 24.8 701 L 101.2" x 30.3" x 42.1" 2570 x 770 x 1070 mm Conventional -86°C 507 351 50,700 208/230V NEMA 6-15 Volume Exterior Dimensions MDF-C8V1-PA 3.0 84 L MDF-594C-PA MDF-794C-PA Model Number (cu.ft.) (w x f-b x h) Storage Storage Storage Voltage, Power Connection 7 MDF-U500VXC-PA Twin Guard® Series MDF-U700VXC-PA Innovative Design: Two independent systems allowing the unit to run continuously at -65°C in the unlikely event of one compressor failure. Patented VIP® PLUS Vacuum Panel: Uniform temperatures with energy efficient and space efficient refrigeration. Ergonomic Design: One-handed outer and inner door latches and compressors to minimize sound. Security Now Comes with Two. What makes Twin Guard® Series a product you can trust? Ultra-Low and Cryogenic Freezers The Most Dependable Ultra-Low Freezers for Long-Term Storage The efficient ultra-low cooling is achieved through two independent evaporator circuits surrounding the interior chamber. The Panasonic Twin Guard® Series satisfies the industry demand for safe, long-term storage for the most high-valued materials. Two independent refrigeration systems, combined with optional liquid nitrogen or liquid CO2 back-up systems, offer a circle of protection unmatched in the marketplace. Developed for use with conventional inventory racks and boxes, the Twin Guard® Series is ideal for storage of sensitive stem cells, embryos, cell lines, and other rare specimens. Traditional Freezer Twin Guard ® Series Ultimate Protection CRITICAL LOST 23°C ULTRA-LOW -65°C -86°C SINGLE COMPRESSOR SYSTEM FAILURE ULTRA- LOW SAMPLE LOSS -86°C SINGLE COMPRESSOR SYSTEM SECOND COMPRESSOR SYSTEM Freezer relies on a single system, causing a complete shut-down when failure occurs Second independent system kicks in to maintain ultra-low temperatures in the event of a failure Performance & Recovery 40 20 0 Pull-up while a power failure -20 -40 Single compressor operation (kept at approx. -65°C or lower depending on load) -60 -80 -100 Normal cycle operation (-80°C setting) 0 1 2 3 4 5 6 7 8 9 10 11 12 (hour) Chamber temp. (°C) 20 Chamber temp. (°C) Give your samples the ultimate protection of patented Twin Guard® technology – two independent systems can individually sustain ultra-low temperatures in the event of a failure, so you can rest easy knowing your valuable work is in good hands. KEY Central air temp. in cabinet Ambient temp. 30°C, No-Load 0 -20 -40 -60 -80 -100 0 1 2 3 4 5 6 7 8 9 10 11 12 Pull-up characteristics during power failure Pull-down charateristics (hour) 9 ??? Panasonic Healthcare Company of North America What is Twin Guard® Technology The Panasonic MDF-U500VXC and MDF-U700VXC Twin Guard® Series ultra-low freezers are designed for -86°C storage of high-value biologicals. Ideal for critical material storage in repositories, highly secure BSL 3/4 labs, GMP facilities, hospitals, clinics and medical research facilities. The Twin Guard® Series introduces the concept of dual, independent, autocascade refrigeration systems contained within a single cabinet. 1. Barrier Film VIP® PLUS Interior Rigid foamed polyurethane 9 3 2. 3. 1 4 4. 5. 11 6. A vacuum relief valve is mounted in the left wall. 7. 8. 7 10 5 8 2 6 9. 10. 12 11. The Panasonic ergonomic design features a highsecurity Easy-In / Easy-Out door latch designed for simplicity and safety. Also allows for one handed operation. 10 12. Panasonic patented VIP® PLUS vacuum insulation panel cabinet construction for high insulating value and increased interior volume in the same footprint. Easy-In/Easy-Out door latch for smooth, one-handed operation, positive seal against gasket. Integrated, microprocessor-based control system and LCD display information center includes comprehensive set-point, alarm, monitoring, diagnostic and communications functions. Insulated, sealed, and gasketed inner doors seal inside to offer additional protection, improve uniformity. New air-cooled super condenser energy transfer technology maintains optimum condenser air flow and eliminates the need for an air filter or reducing the requirement for periodic maintenance. High impact, recessed casters and leveling feet simplify installation. Cool Safe compressors are specifically designed for one-compressor, autocascade applications. Twin Guard® Series redundant refrigeration -86° Dual Cool circuits offer two systems in one, each providing back-up for the other, or working together for fast recovery or energy savings Multiple access ports permit insertion of independent probes, instrumentation or liquid nitrogen or liquid CO2 back-up injectors. CFC-refrigerants are highly efficient, environmentally safe, non-ozone depleting. A vacuum relief valve is mounted in the left wall to ensure easy access to chamber following door closure. Standard remote alarm contacts and optional communication port available. ? ? TECHNOLOGY TWIN GUARD TECHNOLOGY Traditional freezer Traditional Freezer relies on a single freezer Traditional compressor system, -86°C causing a complete freezer Freezer relies on a single shut-down when failure compressor system, occurs. Freezer Temperature relies on a single causing a complete quickly rises to room compressor system, shut-down when failure temperature. causing a complete occurs. Temperature shut-down when failure quickly rises to room occurs. Temperature temperature. quickly rises to room 23°C 23°C -86°C COMPRESSOR FAILURE COMPRESSOR FAILURE temperature. Panasonic Twin Guard® Panasonic freezer Twin Guard® Panasonic Second independent freezer ® Twin system Guard compressor kicks Second independent in to maintain ultra-low freezer temperatures in the event kicks compressor system -86°C -65°C -86°C -65°C of ato failure. Temperature in maintain ultra-low Second independent remains at 65°C. temperatures inkicks the event compressor system in to of a maintain failure. ultra-low Temperature temperatures in the event remains at -65°C. COMPRESSOR FAILURE w of a failure. Temperature COMPRESSOR FAILURE remains at 65°C. So, what is a compressor? Simply put, a compressor is what runs your freezer. It’s the heart of the whole system, keeping your freezer at ultra-low temperatures. The compressor is tied to refrigeration coils that run throughout the unit to maintain those even, sub-zero temperatures. Ultra-Low and Cryogenic Freezers w Traditional Panasonic Compressors are traditionally made up of two parts: a high stage and low stage. These parts rely on one another to operate, so if there is a problem with either part, the entire system shuts down. With Panasonic’s patented Twin Guard technology, 2 compressors are completely separated from one another, with no reliance on the other to operate. So if one of them fails, the other is unaffected and your freezer will keep operating at ultra-low temperatures. A B 11 Panasonic Healthcare Company of North America Optimal Capacity & Footprint Panasonic Twin Guard® series freezers offer a large storage capacity of 576 2" boxes, while maintaining a small footprint with reduced energy usage. This leads to a lower energy requirement per box stored, saving you money in ongoing operational costs. Model Number Temperature Range Interior Volume Area Footprint (nominal) Storage (2"/ 51 mm boxes) Storage (3"/76 mm boxes) Storage (2ml vials in boxes) Electrical, 60Hz MDF-U500VXC-PA -50ºC to -86ºC 18.3 cu.ft. 519 L 8.37 sq.ft. 0.67 m2 352 224 35,200 208/230V NEMA 6-15 MDF-U700VXC-PA -50ºC to -86ºC 25.7 cu.ft. 728 L 9.51 sq.ft. 0.88 m2 576 384 57,600 208/230V NEMA 6-15 Sample Security, Alarms & Monitoring The Twin Guard® series is managed by an integrated microprocessor controller with LCD information center to simplify all freezer functions. • Positive feedback tactile input buttons • Visual alarm indicator •P ositive feedback tactile entry and function keys All performance attributes are displayed on a large, visually intuitive alphanumeric display. Internal temperature log files are expressed in graphical form over time. • Digital LCD display with • Audible alarm alphanumeric information • Pop-up menu • Message display Alarm & Safety Features • Buzzer silence temporarily mutes audible alarm. • Menu call button • Display contrast adjustment Events Audible Signal to Alarm Contact None None Intermittent tone. Time delay of 15 minutes after reaching alarm set-point avoids false alarms. Intermittent tone. Yes Loss of power Intermittent Tone Yes Sensor probe disconnect short circuit or failure Solid Tone Yes Solid tone sounds after 2 minutes Yes Status Alert Inefficient system operation, abnormal ambient, low voltage or heavy loading. High Temperature (Up to +40°C)* Interior chamber cools beyond high temp set-point Low Temperature (Up to -40°C)* Interior chamber warms beyond low temp set-point Power Failure Control Temperature Sensor Failure Door Alarm Out-of-compliance events are announced by visual and audible warnings. Error codes quickly identify problem sources and permit fast diagnosis and remediation. Door open Visual Notification of error on graphical display Notification of error on graphical display Yes *Extended range is important for GxP applications to reduce potential incident event reporting. The integrated microprocessor control aggregates information from the entire system and compares to normal or set-point values. Out-of-compliance events are announced by visual and audible warnings, and remote alarm when connected to an external system. 12 Ultra-Low and Cryogenic Freezers Normal Normal Eco Mode vs. Normal Mode ECO mode operation image Pull down Stable temperature Chamber temp T12 on T12 off Comp A Comp B 2 compressors are turned ON/OFF at same time Temp. ECO mode mode ECO Comp A Comp B Chamber temp T on T1 off T12 on T2 off T1 2 on Comp A Comp B NORMAL mode operation image Pull down Chamber temp Stable temperature T12 on Temp. Comp A Comp B Comp A Comp B T12 off T2 on T2 off 2 compressors and fan motor for each are independently controlled by SV and read AT. This chart shows the repeatable cycling wave form of normal mode vs. eco mode. Normal mode is for strict GMP applications. The Panasonic Twin Guard® Series Freezer can be set for Normal or EcoMode operation. EcoMode establishes an overlapping cycle to reduce energy consumption. Technical Specifications Description Model Number MDF-U500VXC-PA MDF-U700VXC-PA Temperature Set-point Range -50°C to -86°C Design Cooling Performance -86 Dual°Cool (both compressors) -86°C (ambient temperature 30°C) Single System Cooling Performance (Indefinite) -65°C (ambient temperature 30°C) Cabinet Design and Construction Cabinet Insulation Patented VIP® PLUS composite wall Exterior Dimensions (w x f-b x h) 35.5” x 40” x 78.3” 770 x 870 x 1990 mm 42.5” x 40” x 79.1” 1010 x 870 x 2010 mm Interior Dimensions (w x f-b x h) 25.6” x 23.6” x 54.3” 630 x 600 x 1380 mm 34.3” x 23.6” x 55.1” 870 x 600 x 1400 mm 18.3 cu.ft. 519 liters 25.7 cu.ft. 728 liters Volume Shelves Access Port Vacuum Release Port 3, adjustable, stainless steel (4 compartments) Diameter = 0.5”/17mm; 3 locations Standard, Manual Refrigeration System Refrigeration Technique Compressors Refrigerant Panasonic -86 Dual°Cool independent, redundant cooling systems with automatic switchover Per system: Single, hermetically-sealed 1100W Panasonic Cool Safe compressor, air-cooled Environmentally safe HFC refrigerant Air Exchange Dual condenser fans with particulate trap; no filters are required Cycle Options Standard or energy-saving EcoMode operation Controls, Alarm, Monitoring Controller Data Management Communications Alarms Remote Alarm Contacts Electrical Panasonic microprocessor-based, door-mounted control with graphical LCD information center Internal data log with log file memory Data can be transmitted via RS485, optional 4-20 mA High/Low temperature, door ajar, power failure, remote alarm contact, part replacement notification, fan motor lock, individual cooling circuit check Standard; normally open or normally closed, dry contacts 208V-230V, AC, 60Hz, 1 phase, NEMA 6-15, 15 amp separate breaker recommended 13 Panasonic Healthcare Company of North America MDF-U500VXC Dimensional Drawings 21.0” (533) MDF-U700VXC 34.3” (870) 14 MDF-U56VC-PA VIP® Series MDF-U76VC-PA Leading Performance with Greater Energy Savings. What makes VIP® Series so green? Thinking Green: Environmentally friendly refrigerants, RoHS compliant and low-noise operation. Panasonic Healthcare Company of North America What makes VIP® Freezers so Reliable? Panasonic VIP® ultra-low freezers represent the industry’s most complete combination of refrigeration, control, alarm, monitoring and accessibility for product safety at -86°C. Ideal for material storage in repositories, hospitals, clinics and medical research facilities, the VIP® Series freezers are designed to reduce energy consumption and offer optimal performance. Combination of patented VIP® plus vacuum insulation panel with Panasonic designed compressors specific to ultra-low applications, result in unmatched uniformity, that surpasses the strictest protocols, no matter where your samples are stored within the unit. Surpasses the customer preference of +/- 5°C* +5°C UNIFORMITY Performance Panasonic compressors employs a unique orientation of components that increases compressor longevity and refrigeration capacity while reducing operating pressure and discharge temperatures – a key component that yields better reliability. Validated temperature recovery Pull down speed from room temperature to -80°C Pull down speed from room temp to -80°C -5°C 30% faster 3 (Hours) 6 * The data may vary depending on the use, circumstances and optional accessories. Validation documents can be provided for each serial number with an additional fee. 16 15 more efficient 10 5 Brand A Brand B Energy Efficient Cascade Cooling Panasonic cascade refrigeration system and the new improvements in the heat exchanger design drastically increase the efficiency of the entire system. The end result is less enerefficiency and reliability of the freezer. Brand B 0 20 up to 31% gy consumption, while improving the overall Brand A Based on internal validation data tested at -80°C setpoint, in an empty chamber with 23°C ambient temperature. 25 Panasonic Increased reserve cooling capacity improves temperature recovery after door openings Panasonic Energy Savings Consumed Power (kWh / day) Uniformity you can trust 9 Ultra-Low and Cryogenic Freezers VIP® Series -86°C Freezer Energy Efficient Cascade Cooling System NEW! High Efficiency Heat Exchanger Low stage capillary tube heat exchanger provides optimum heat transfer between high and low temperature points in the low stage leading to greater energy efficiency. Main Condenser and Motor/Fan Assembly Panasonic’s exclusive triple pass forced air condenser increases overall system efficiency by providing maximum surface area for heat rejection. High Stage Refrigerant Low Stage Refrigerant Commonly available worldwide, R508. Industry Standard. Commonly available worldwide. Selected for optimum cooling performance in compliance with international environmental protection laws. Low Stage Compressor Compresses and pumps refrigerant through the low stage circuit. Oil Heat Exchanger Panasonic exclusive high stage refrigerant passes through both compressor oil sumps to cool lubricating oil resulting in high-stage refrigerant being used to increase the durability of the compressors. Instrumentation (Not Shown) Temperature and pressure sensors throughout the high and low stage circuits transmit information to the Panasonic ‘Status Alert’ central controller for operation, monitoring, interpretation and component protection. 17 Panasonic Healthcare Company of North America VIP® Features 1. asy-In/Easy-Out door latch for smooth, oneE handed operation, positive seal against gasket. Padlock provision standard. 2. Integrated, microprocessor-based control system and LED display includes comprehensive set-point, alarm, monitoring, diagnostic and communications functions. 3. Insulated and gasketed inner doors seal inside to offer additional protection and improve uniformity. Inner door latches are standard. Doors can be easily removed for defrosting. 4. ront access to washable, electrostatic condenser F filter for routine condenser air filter cleaning. 5. igh impact, recessed casters and leveling feet H simplify installation. 6. ew generation Panasonic designed Cool Safe N compressors are specifically designed for low temperature applications. 7. ultiple access ports permit insertion of M independent probes, instrumentation or liquid N2 or liquid CO2 back-up injectors. 2 10 3 8. 7 ommercially available HFC-refrigerants are highly C efficient, environmentally safe and non-ozone depleting. 9. emote alarm contacts and optional R communication port available; see Accessories. 10. acuum relief valve (Available on the MDF-U56VC, V MDF-U76VC, and MDF-U76VA) 4 9 5 8 The Panasonic ergonomic design features a high-security Easy-In/Easy-Out door latch designed for simplicity and safety. Also allows for one handed operation. 6 1 A. Optional Accessories A B C B. C. D E D. E. 18 Inventory Rack Systems: Panasonic freezers are available with a variety of inventory racks to meet specific applications. Freezers can be ordered with full-load inventory systems by selecting one catalog number. The Digital Temperature Recorder: The recorder mounts on the cabinet door and is programmable to capture and store non-corrutible data points for downloading to an independent data management system to meet criteria outlined in U.S. FDA 21CFR Part II directives. An independent probe is placed in the interior chamber. Touch-Screen Display: A touch-screen digital display with full color graphing capabilities of your complete temperature history is at your fingertips with scrolling and zoom. The touch screen monitor fits on the front panel of your Panasonic equipment either in place of the recorder or at eye level and is designed to work without software. Software is optionally available if you wish to download your data to PC via USB or flash memory for archiving to meet criteria outlined in U.S. FDA 21CFR Part 11 directives. Circular Recorder, Strip Chart Recorder and Recorder Mounting Bracket CO2 Backup System and LN2 Backup System Ultra-Low and Cryogenic Freezers Options & Accessories Water Cooled Condenser Description Water Pressure & Temperature Maximum Water Pressure: 150psig, Minimum Water Pressure Differential: 15psig, Maximum Water Temperature: 30°C Connections Typically ½” compression fittings on inlet and outlet but can be customized for customer needs Required Water Flow Rate (Maximum) Tower Water: 11.4 liters per minute Qualified technician required at time of installation to balance water flow requirements. Efficiencies can be easily obtained regarding water usage by balancing the water flow to optimum usage and freezer efficiency dependent upon the specific site installation Installation Accessory Description Catalog Number Set of two; Field Installed; replaces half inner door; for a four-door configuration order two sets MDF-5ID-PW (MDF-U53VA), MDF-5ID1-PW (MDFU-56VC), MDF-7ID1-PW (MDF-U76VC / MDF-U76VA) Digital Temperature Recorder Auxiliary Data Logger HAMSTERDT2 Liquid CO2 Back-Up System Auxiliary back-up in event of power failure CVK-UB2(I)-PW Liquid N2 Back-Up System Auxiliary back-up in event of power failure CVK-UBN2-PW Circular Chart Temperature Recorder, 7 Day MTR-C954 Chart Paper 6” Diameter, 7 Day Chart C7100386REV Replacement Pen, Red / Blue Felt tip pens, 6 per pack R252 / R253 Digital Touch Panel Recorder Programmable digital temperature recorder FT560SN Data Logging Software For use with touch panel recorder A016 21 CFR Part 11 Compliant Software For use with touch panel recorder A026 Half Inner Door Chart Recorder Annual CO2 Emissions by Box Capacity Pounds / Box Capacity 5 4 3 up to 40% 4.97 4.33 lower emissions Energy Less Emission VIP® freezers help the environment by reducing carbon footprint. 2.99 2 0 $4 3.04 up to 40% less cost 2.64 1.83 $1 $0 Cost is an average for operating freezer including cost to remove heat from the room generated by the freezer. .04 KW / day / box capacity Total annual operating cost for operation and cooling by capacity Dollars / Box Capacity MDF-U76VC Brand A Power Consumption By Capacity (KW/day/box capacity) Panasonic freezers help the environment by reducing carbon footprint. $2 Panasonic Brand B 1 $3 Performance up to .03 .02 39% .038 .043 more efficient .026 .01 0 More Efficient Panasonic VIP® freezers provide reduced operational cost for highly efficient sample storage. Panasonic freezers provide reduced operational cost for highly efficient sample storage.* Operating Cost Panasonic freezers emit less heat into the laboratory, minimizing air conditioning costs. 19 Panasonic Healthcare Company of North America Operating Analysis The superior energy efficiency of Panasonic VIP® Series Ultra-Low Freezers leads to significant annual cost savings. Lower kW usage combined with lower heat rejection leads to savings on freezer operation costs plus associated HVAC costs to remove heat from the room generated by the freezer. With an industry-leading capacity of up to 576 2” boxes, the energy-saving advantages of this efficient Panasonic system extend to lower per-unit storage costs regardless of the preferred inventory configuration. The concept of High Density Storage is enabled by advances in Panasonic Cool Safe compressor design. The cost per 2” box of interior storage space is significantly lower in a Panasonic ultra-low freezer, generating immediate return on investment based on first costs, operating costs and maintenance costs over time. 30 31.1% 25 3000 2000 1000 0 Dollars 21% up to 31% 10 less cost annually 5 0 2500 Total Operating Cost of 1 Unit 2000 3000 2000 1000 0 Brand A Brand B $1241 $146 $248 1 Year $730 5 Years Total Operating Cost of 1 Unit $3978 2 Years 3 Years $3467 $3467 4 Years Panasonic MDF-U76VC 5 Years Brand A $2737 up to Brand B 31% less cost annually $547 $ $54 7 $ 3 $69 $693 $795 1 Year 2 Years 3 Years Sample Security, Alarms & Monitoring The Panasonic microprocessor control system is secure, easy to use and comprehensive. Set-point, alarm parameters and self-diagnostic functions are accessed through a tamper-resistant keypad protocol. Control inputs are managed with convenient push buttons on a unitized, sealed control overlay. The panel is door-mounted and angled for easy access. 20 MDF-U76VC $2737 4000 1 Year Panasonic $3467 $3467 1000 500 Brand B $3978 1500 0 vs. Brand A vs. Brand B $795 $ 3 $69 $693 $547 $ $54 7 Brand A 4 Years 5 Years Status alert function uses predictive intelligence to • determine if freezer is operating within specifications under existing environmental conditions. • Adjustable compressor startup delay sequence delays re-start after building power failure; allows facility power to reach equilibrium to permit smooth compressor start-up. • Digital display defaults to actual chamber temperature. Display mode changes when set-point, alarm parameters, programming and diagnostic functions are performed. • Panasonic exclusive Ni-MH battery powers control memory and alarm functions during power failure. • Alarm indicator lamp glows when freezer is in alarm condition; alarm ringback is factory set for 30 minutes, adjustable in 10 minute increments from 10 to 60 minutes. • Filter indicator lamp glows when electrostatic filter requires removal for cleaning. • Audible alarm. Buzzer silence • temporarily mutes audible alarm. 4000 4000 Dollars Dollars Dollars 4000 20 15 Operating Cost Savings per Unit - 1/5/10 Years Panasonic MDF-U76VC vs. Brand A and B $ Savings - Per Unit % Savings –Panasonic MDF-U76VC Operating Cost Savings Percentage 3000 3000 2000 2000 1000 1000 Alarm test verifies readiness • of alarm function and Ni-MH battery charge. Total Cost of Total Operating Operating Cost of 1 1 Unit Unit • Set-point entry advances digital display to next position. Press to set temperature; set button is also • used for other diagnostic functions. up to to up 31% 31% less cost less cost annually annually $693 $69 3 $693 $69 $ $693 Adjustable alarm set-points are factory set 10ºC above and below set-point. Alarm parameters are adjustable by pressing up or down arrow keys and following the prompt. $795 $795 • Door alarm indicator has 2 minute delay until audible alarm activates; delay time is adjustable. • Set-point entry advances digital to next $34 $3467 3467 67 value from 0 to 9. $2737 $3978 Ultra-Low and Cryogenic Freezers Optimal Capacity & Footprint High Density Storage The concept of is enabled by advances in Panasonic Cool Safe compressor design. The cost per 2” box of interior storage space is significantly lower in a Panasonic VIP® ultra-low freezer, generating immediate return on investment based on first costs, operating costs and maintenance costs over time. Maximum Sample Storage Capacity Description Model Number MDF-U33V-PA MDF-U53VA-PA MDF-U56VC-PA MDF-U76VC-PA MDF-U76VA-PA 3 Columns 4 Rows 4 Columns 4 Rows 4 Columns 4 Rows 6 Columns 4 Rows 6 Columns 4 Rows Rack Positions, Standard Configuration Fiberboard Boxes, 2” high (2ml) in Racks 216 352 384 576 576 21,600 35,200 38,400 57,600 57,600 144 224 256 360 384 Sample Vials, 4ml (3” box), 100-Cell Dividers 14,400 22,400 25,600 38,400 38,400 Standard Microplate with Foil Tape, in Racks 1,298 2,112 2,112 3,456 3,456 Standard Microplate with Cover Lid, in Racks 1,008 1,632 1,632 2,596 2,596 Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Sample Vials, 2ml (2” box), 100-Cell Dividers Fiberboard Boxes, 3” high (4ml) in Racks Fully Loaded Inventory Systems Maximum Vial Capacity Includes full quantity of storage racks, boxes and dividers Sliding Drawer Inventory Racks 2” High Boxes (2ml Sample) 100-Cell Divider (6) GRD442A (6) GRD452SS (8) GRD462SS (8) GRD452SS (8) GRD443A (8) GRD452SS (24) GRD462SS (24) GRD462SS Sliding Drawer Inventory Racks, 3” High Boxes (4ml Sample) 100-Cell Divider (12) GRD433A (8) GRD443A (8) GRD433A (8) GRD443A (8) GRD452SS (18) GRD443A (6) GRD433A (24) GRD443A Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number GRF462SS Capacity 8 GRF462SS Capacity 16 GRF462SS Capacity 24 GRF462SS Capacity 24 GRD443A Capacity 8 GRD443A Capacity 8 GRD443A Capacity 24 GRD443A Capacity 24 GRD433A Capacity 8 GRD433A Capacity 8 GRF462SS Capacity 8 GRF462SS Capacity 16 GRF462SS Capacity 24 GRF462SS Capacity 24 GRF443A Capacity 8 GRF443A Capacity 8 GRF443A Capacity 24 GRF443A Capacity 24 GRF433A Capacity 8 GRF433A Capacity 8 Individual Storage Rack System Sliding Drawer Sample Racks for Fiberboard Storage Boxes (Boxes Not Included) Sliding Drawer Rack, for 2” high (2ml sample) boxes; holds 6 boxes high x 4 boxes deep Sliding Drawer Rack, for 2” high (2ml sample) boxes; holds 5 boxes high x 4 boxes deep GRD452SS Capacity 6 Sliding Drawer Rack, for 2” high (2ml sample) boxes; holds 4 boxes high x 4 boxes deep GRD442A Capacity 6 Sliding Drawer Rack, for 3” high (4ml sample) boxes; holds 4 boxes high x 4 boxes deep Sliding Drawer Rack, for 3” high (4ml sample) boxes; holds 3 boxes high x 4 boxes deep GRD433A Capacity 12 GRD452SS Capacity 8 Standard Cellular Inventory Racks for Fiberboard Storage Boxes (Boxes Not Included) Inventory Rack for 2” (2ml sample) boxes; 6 boxes high x 4 boxes deep Inventory Rack for 2” (2ml sample) boxes; 5 boxes high x 4 boxes deep GRF452SS Capacity 6 Inventory Rack for 2” (2ml sample) boxes; 4 boxes high x 4 boxes deep GRF442A Capacity 6 Inventory Rack for 3” (4ml sample) boxes; 4 boxes high x 4 boxes deep Inventory Rack for 3” (4ml sample) boxes; 3 boxes high x 4 boxes deep GRF433A Capacity 12 GRF452SS Capacity 8 21 Panasonic Healthcare Company of North America Technical Specifications Description Model Number MDF-U33V-PA MDF-U53VA-PA MDF-U56VC-PA MDF-U76VC-PA MDF-U76VA-PA Interior Volume 11.8 cu.ft. 333 L 18.3 cu.ft. 519 L 18.6 cu.ft. 526 L 25.7 cu.ft. 728 L 25.7 cu.ft. 728 L Area Footprint, Nominal 6.25 sq.ft. 0.58 m2 7.24 sq.ft. 0.67 m2 7.24 sq.ft. 0.67 m2 9.51 sq.ft. 0.88 m2 9.51 sq.ft. 0.88 m2 115V, AC, 15 amp 115V, AC, 20 amp 208/230V, AC, 15 amp 208/230V, AC, 15 amp 115V, AC, 20 amp Electrical, 60 Hz Patented VIP® Construction Insulated Inner Door Inner Door Configuration Steel-framed, high impact plastic with foam-in place insulation 2 2 (4 optional) 2 (4 optional) Door Gaskets 2 (4 optional) 2 (4 optional) Multi-point compression gaskets Condenser Filter, Easy Cleaning Electrostatic filter standard, front accessible for easy access, no tools required Rounded Interior Corners Simplify Cleaning Shelf Brackets Incrementally adjustable Casters High-impact 4 with leveling feet Seismic Restraints Standard; hard connection to facility wall Access Ports Multiple ports allow use of injection tubes, probes, leads, instrumentation Dimensions & Weight Interior (w x f-b x h) 19.3” x 23.6” x 44.9” 490 x 600 x 1140 mm 24.8” x 23.6” x 54.3” 630 x 600 x 1380 mm 24.8” x 23.6” x 55.1” 630 x 600 x 1400 mm 34.2” x 23.6” x 55.1” 870 x 600 x 1400 mm 34.2” x 23.6” x 55.1” 870 x 600 x 1400 mm Exterior (w x f-b x h) 26.4” x 34.1” x 73.2” 670 x 870 x 1860 mm 30.3” x 34.4” x 78.3” 770 x 870 x 1990 mm 30.3” x 34.4” x 78.3” 770 x 870 x 1990 mm 39.8” x 34.4” x 78.3” 1010 x 870 x 1990 mm 39.8” x 34.4” x 78.3” 1010 x 870 x 1990 mm Net Weight, Empty 562 lbs 255 kg 660 lbs 290 kg 672 lbs 305 kg 805 lbs 365 kg 820 lbs 373 kg Refrigeration System, HFC Refrigerants, Panasonic Cool Safe High Performance Compressors High Stage 1 HP ½ HP 1 HP 1 HP 1 HP Low Stage ¾ HP 1 HP 1½ HP 1½ HP 1½ HP Not Available Not Available Standard Standard Not Applicable Standard Standard Standard Standard Standard Voltage Booster, Built-In Sound Abatement Refrigeration System, HFC Refrigerants, Panasonic Cool Safe High Performance Compressors Power, AC, 1 Phase Recommended Breaker, Dedicated NEMA Plug / Receptacle 22 115V 115V 208-230V 208-230V 115V 15 amp 20 amp 15 amp 15 amp 20 amp 5-15P/5-15R 5-20P/5-20R 6-15P/6-15R 6-15P/6-15R 5-20P/5-20R PRO Series MDF-U7486SC-PA MDF-U5486SC-PA Insulated for Reduced Carbon Footprint What makes PRO Series freezers so efficient? Thinking Green: Environmentally friendly refrigerants, RoHS compliant and low-noise operation. Panasonic Healthcare Company of North America PRO Series -86ºC Freezer Performance Advantages Panasonic’s conventionally insulated PRO Series ultra-low freezers provide energy savings while minimizing carbon footprint throughout the laboratory without compromising performance. It also maintains the internal temperatures as low as -86°C. All models use Panasonic-designed compressors for ultra-low temperature applications. Manufactured with foam-in-place insulation to maximize interior temperature uniformity, they are ideally suited for use in hospitals and laboratories for long-term preservation and storage of specimens and components, as well as material testing. 1 2 The Panasonic ergonomic design features a high-security Easy-In/ Easy-Out door latch designed for simplicity and safety. The outer door latch closes smoothly with a single-hand action over a cam action bearing. The outer door can be secured with an independent padlock provided by customer. 11 6 Inner Door Latches provide single-hand access. 4 10 7 9 8 3 24 5 1. he insulation used in Panasonic’s PRO T Series ultra-low temperature freezers is high density rigid, foamed-in-place polyurethane. This design prevents the insulation layers from distortion and cracking that might occur due to temperature differences inside and out. 2. rgonomic one handed Easy-In / Easy Out E outer door latch will accept a padlock. 3. 4. Microprocessor-based controller. 5. Insulated sealing inner doors help maintain interior temperature during routine openings. Two inner doors are standard. 6. 7. “Eagle Beak” inner door latches. 8. igh impact recessed casters simplify H installation. 9. anasonic designed compressors specifically P designed for low temperature use offer maximum reliability. 10. ultiple access ports permit independent M probes, instrumentation or liquid CO2 back-up system injection. 11. Vacuum release port. emote alarm contacts can be connected to R independent monitoring system. asy front access to washable, electrostatic E condenser filter for routine condenser air filter cleaning. Panasonic microprocessor-based controller includes comprehensive set-point, alarm, monitoring and diagnostic functions. Ultra-Low and Cryogenic Freezers PRO Series Comparative Energy Performance Power Consumption by Capacity (KW/day/box Efficiency) Total Annual Electrical Cost per Box Capacity 3.0 12 2.5 10 Watts 1.0 0.5 0.0 Panasonic freezers provide reduced operational cost for highly efficient sample storage*. 10.27 0.9 10.93 0.8 0.7 6 0 Panasonic freezers emit less heat into the laboratory, minimizing air conditioning costs*. 0.88 Panasonic MDF-U7486SC 0.5 Brand A 0.4 4 2 0.89 0.82 0.6 Dollars ($) 2.21 1.73 1.0 11.11 8 Dollars / Cubic Foot 2.25 2.0 1.5 Annual CO 2 Emissions by Box Capacity Brand B 0.3 0.2 0.1 0 Panasonic freezers help the environment by reducing carbon footprint*. *Based on internal performance data. Tested in 25°C ambient environment. Freezer cycling at -80°C. Cabinet volume, 25 cu. ft. Average cabinet temperature based on temperature mapping (15 thermocouples). Technical Specifications Description Model Number MDF-U5486SC-PA MDF-U7486SC-PA High Stage 1100 W 1100 W Low Stage 1100 W 1100 W Standard Standard Standard (< 51dB(A)) Standard (< 51dB(A)) Refrigeration System, HFC Refrigerants, Cool Safe High Performance Compressors Voltage Booster, Built-In Sound Abatement Construction Shelf Stainless steel, adjustable 3 shelves Access Port .066" (17 mm) diameter, Refrigerants HFC refrigerants Alarm Remote Alarm Contact High/low temp, Power failure, Filter check, Battery check N.O. and N.C., allowable contact capacity: DC30V, 2A 25 Panasonic Healthcare Company of North America Cryogenic Freezer MDF-C2156VANC-PA Temperature Uniformity for Long-term Storage What keeps our Cryogenic freezer so stable? Panasonic Cryogenic freezer maintains uniform temperature of -150°C for stable, long-term preservation of cells and tissue. Panasonic VIP® PLUS Cryogenic Series -150°C ultra-low temperature freezer achieves more storage capacity than a conventionally insulated freezer without increasing footprint. Liquid Nitrogen freezer ( Vapor Phase ) Panasonic MDF-C215VANC mechanically refrigerated cyrogenic freezer Uniform Cryogenic Temperatures Comparison of temperature distribution in a liquid nitrogen freezer (vapor phase) and Panasonic’s MDF-C2156VANC mechanically refrigerated cryogenic freezer. Graph shows temperatures at different locations within the chamber. This data demonstrates that 100% of the MDF-C2156VANC-PA storage space maintains uniform storage temperatures safely below -130ºC, while temperature in LN2 vapor system is dependent on storage location. ±5ºC uniformity* in a mechanically refrigerated design promotes better top-to-bottom uniformity than liquid nitrogen vapor-phase storage, without the concern of cross-contamination often associated with liquid nitrogen (liquid phase storage). Based on internal validation data tested at -150°C setpoint, in an empty chamber with 23°C ambient temperature. * The data may vary depending on the use, circumstances and optional accessories. Validation documents can be provided for each serial number with an additional fee. 26 Ultra-Low and Cryogenic Freezers Product Features • Warning indicator (Lit even during power outage) • Setting input • Patented revolutionary vacuum insulation cabinet construction reduces wall thickness and achieves more storage capacity than a conventionally insulated freezer without increasing the footprint. • The newly developed refrigeration system and the freezer structure offer a quiet environment. • Graphic display (LCD) • Achieves 50% higher energy conservation than conventionally insulated model. • Warning information • Buzzer silence: Hold for alarm test • Status display • The temperature inside the freezer can be set and monitored easily by means of precise microprocessor temperature control with an LCD graphic display. The controller utilizes a platinum RTD sensor which is extremely precise and durable. • Door display • Status Alert monitors ambient and system conditions continuously and notifies of any abnormalities before a problem can occur. In case of power failure or an irregular rise in temperature, a rechargeable, high capacity battery-operated indicator lamp and alarm will be activated. • Graphic LCD panel with pop-up menu function on control panel provides a precise visual display and allows intuitive operation. • VIP® PLUS offers superior performance in insulating properties providing unsurpassed uniformity in the chamber- top to bottom, side to side, front to back. • The MDF-C2156VANC is equipped with LN2 backup system as standard to prepare for any contingency. The built-in LN2 back-up system is self activated if a power outage occurs. This feature helps ensure that the contents will be protected in the event of any power failure. Technical Specifications Description Model Number Temperature Range Max Cooling Performance MDF-C2156VANC-PA -125°C to -150°C (1°C increments) -150°C (ambient temp 30°C) Uniformity ±7°C at -150°C (empty chamber, ambient temp 24°C) Capacity 8.2 cu.ft. 231 liters Exterior Dimensions (w x f-b x h) 68.1” x 30.1” x 39.8” 1730 x 765 x 1010 mm Interior Dimensions (w x f-b x h) 29.9” x 19.5” x 24.2” 760 x 495 x 615 mm Net Weight Approx.715lbs (325kg) Access Port 40mm diameter, 1 location Compressor Hermetic type, 1100W (high stage side) 1100W (low stage side) Refrigerants HFC Free Alarm Remote Alarm Contact Power Requirements High/Low temperature, power failure, filter check, self diagnosis, lid check Allowable contact capacity DC 30V, 2A 208V-230V, 1 phase, 60Hz NEMA 6-15R (15 Amp) Receptacle 27 Panasonic Healthcare Company of North America Chest Freezers MDF-C8V1-PA MDF-794C-PA Space-Saving Stability What makes Chest freezers compact yet equally effective? All ultra-low chest models use Panasonic-designed compressors for ultra-low temperature applications. Manufactured with foamed-in-place insulation, they are ideally suited for use in hospitals and laboratories for long-term preservation and storage of specimens and components, as well as materials testing. Product Features Microprocessor Controls Comprehensive set-point, alarm, monitoring and diagnostic functions based on Panasonic-built microprocessor controller with digital display of all input/output functions. Panasonic-Designed Refrigeration and Compressors Designed by Panasonic specifically for rugged ultra-low temperature applications in a laboratory environment; HCFC-free refrigerants only. High-performance refrigeration system with foam-in-place cabinet insulation maximizes interior temperature uniformity and protects against fluctuating ambient temperatures. High Density Blown-In Foam Insulation and Heated Gasket Seal In ultra-low temperature freezers, effective insulation is critical. • The insulation used in Panasonic ultra-low freezers is two layers of rigid, foamed-in-place polyurethane, placed together to form a double-insulation wall. 28 • This design prevents the insulation layers from distortion and cracking that might occur due to temperature differences inside and out. • Frost and icing on the top edges and gaskets are prevented by utilization of a heated mullion, which recycles heat from the refrigeration system without affecting chamber uniformity. Built-In Temperature & Power Failure Alarms (Lamp/Buzzer) In case of power failure or an irregular rise in temperature, a high capacity, rechargeable battery-operated indicator lamp and alarm will be activated. Optional CO2 and LN2 back-up systems are available and are self-activated when a power outage occurs. This equipment helps ensure that the contents will be protected in the event of any power failure or mechanical trouble. Ultra-Low and Cryogenic Freezers Technical Specifications Description Model Number MDF-C8V1-PA Temperature Range -60°C to -80°C (-1°C increments) Max Cooling Performance -80°C (Ambient Temp 30°C) Effective Capacity 3.0 cu.ft. (85 liters) Exterior Dimensions (w x f-b x h) 21.6” x 27.0” x 37.2” / 550 x 685 x 945 mm Interior Dimensions (w x f-b x h) 15.9” x 19.3” x 16.9” / 405 x 490 x 425 mm Net Weight Approx. 148lbs (67kg) Storage Capacity 2" Box: 42 pcs. (SCR-072 x 6 racks) 3" Box: 30 pcs Outer Door / Inner Door Outer Lid: 1 piece; Inner Lid: 1 piece Insulation VIP® PLUS rigid polyurethane foam (HC) Cooling System 115V / 60Hz / 1 Phase NEMA 5-15P Plug Compressor Rotary Type Refrigerant HFC Evaporator Tube on Sheet Type Alarm System High / Low Temp. Alarm (±5°C to ±20°C); Power Failure Alarm; Remote Alarm Contact: DC30C, 2A (N.O./N.C.) Description Model Number MDF-594C-PA MDF-794C-PA Temperature Range -20°C to -86°C Cabinet Insulation Rigid polyurethane foamed-in place Exterior Dimensions (w x f-b x h) 79.1” x 30.3” x 42.1” / 2010 x 770 x 1070 mm 101.2” x 30.3” x 42.1” / 2570 x 770 x 1070 mm Interior Dimensions (w x f-b x h) 50.3” x 19.7” x 30” / 1280 x 500 x 762 mm 72.4” x 19.7” x 30” / 1840 x 500 x 762 mm 19.2 cu.ft. (487 Liters) 24.8 cu.ft. (701 Liters) Effective Capacity Exterior Cabinet Painted Steel Interior Cabinet Stainless Steel Inner Sub-Lid 3 4 672lbs (303kg) 827lbs (347kg) Compressor (high stage) Hermetic type 750W Hermetic type 1100W Compressor (low stage) Hermetic type 750W Net Weight (approx.) Hermetic type 1100W Evaporator (high stage) Cascade condenser Evaporator (low stage) Tube on sheet (shared with interior) Condenser (high stage) Fine and tube type Condenser (low stage) Shell and tube type Temperature Control Microprocessor: Keypad input; Temp. input range: -20°C to -86°C (1C increment); Set value memory: nonvolatile memory Temperature Display Digital Display Sensor Alarm System Platinum Resistance (Pt. 100) Selectable high temp. alarm (+10°C & +15°C from set point), Power Failure alarm, Filter check lamp, Remote alarm contact Power Requirement 208 / 220V / 60hz built-in voltage booster Thinking Green: Environmentally friendly refrigerants, RoHS compliant and low-noise operation. 29 Product Service and Uptime Assurance Your Panasonic experience with product safety, reliability and performance is supported by a multi-national network of factory-trained service professionals located in all markets we serve. The serviceability of Panasonic Healthcare products is inherent to all Panasonic product designs and originates in our research and development department. Combined with customer feedback and detailed documentation of field performance, Panasonic product developers incorporate real-world applications into product systems and operating parameters. From ambient temperature and humidity fluctuations to broad electrical voltage tolerances, Panasonic Healthcare products are expected to withstand demands in the newest of facilities as well as older labs. Central to our product development efforts is the concept of “predictive performance”, a matrix of electronics and control functions that sense component operation in real time, compare performance to accepted norms and report exceptions long before normal wear and tear causes an interruption. As a result, many Panasonic Healthcare products include self-diagnostics that permit authorized service technicians to determine how and when service calls are required. As Panasonic continues to apply improvements in compressor and electronics to all products, life cycle costs can be extended and downtime minimized. Panasonic service specialists are trained to perform remote and on-site diagnostics, repair and replace worn components and offer preventative maintenance programs suitable to your needs and budget. Panasonic Healthcare also offers training to selected facility biomedical engineers and service staff for authorized in-warranty and post-warranty repairs. Because Panasonic Healthcare products are sold and serviced worldwide, products acquired in one country under grant or facility-sharing programs are easily supported if moved to facilities in the next city or around the world. Validation Services Panasonic offers a wide range of high-quality validation services for all our equipment. These services include on-site validation, custom validation support packages, factory acceptance testing, and NIST traceable calibration. Choosing Panasonic as an equipment supplier and validation consultant can greatly reduce the time and cost involved with new equipment. Unique Services Panasonic Offers: • On-site consultation • Specialized documentation for each individual unit • Customized testing procedures based on personalized customer requirements • No charge for documentation when service is purchased • Quality documents complying with 21 CFR traceable standards • Free archiving of unexecuted testing protocols Pre-Delivery and On-Site Services Pre-delivery services include factory acceptance testing, calibration, and temperature mapping. On-site services include installation qualification, operational qualification, performance qualification, calibration and temperature mapping. Panasonic Connect Panasonic’s customer-driven service program guarantees local attention from qualified Panasonic service representatives, whenever and wherever you need it. • New Unit Installation and Training • Preventative Maintenance • Warranty and Non-Warranty Repairs • Calibration/Validation Services • Refurbishment and Reconditioning • Customized Service and Warranty Programs • Loaner Units When Needed • In-Stock Parts for Immediate Delivery Prices and conditions may vary by market. Panasonic Healthcare Company of North America 1300 Michael Drive, Suite A, Wood Dale, IL 60191 Toll Free USA (800) 858-8442, Fax (630) 238-0074 www.panasonic.com/biomedical © Panasonic Printed in USA 2013.04 AG
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2013:04:10 10:27:05-05:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2013:06:07 11:27:19-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:06:07 11:27:19-05:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:46efc62d-ebc3-48b3-879f-0c948bfdb85e Original Document ID : xmp.did:C687358C1B2068118083B560AB157BF8 Document ID : xmp.id:01801174072068118083F816B9160332 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:1C5648B3172068118083C98F4C2C6F99 Derived From Document ID : xmp.did:20EED26E0A2068118083F02C0BC31FF6 Derived From Original Document ID: xmp.did:C687358C1B2068118083B560AB157BF8 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:04:10 10:27:05-05:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 30EXIF Metadata provided by EXIF.tools