MDF U700VXC Panasonic Freezer Catalog

User Manual: MDF-U700VXC

Open the PDF directly: View PDF PDF.
Page Count: 30

VIP® Series | Twin Guard® Series
PRO Series | Cryogenic | Chest
VIP® Series | Twin Guard® Series
PRO Series | Cryogenic | Chest
Ultra-Low and
Cryogenic Freezers
Ultra-Low and
Cryogenic Freezers
www.panasonic.com/biomedical
Twin Guard® Series
MDF-U700VXC-PA
Twin Guard® Series
MDF-U700VXC-PA
Give your samples
the ultimate protection.
Give your samples
the ultimate protection.
-150°C Cryogenic Freezer
MDF-C2156VANC-PA
-150°C Cryogenic Freezer
MDF-C2156VANC-PA
VIP® Series
MDF-U76VC-PA
VIP® Series
MDF-U76VC-PA
The Industry’s Most
Complete Ultra-Low
Storage Solution.
The Industry’s Most
Complete Ultra-Low
Storage Solution.
Offer your samples the advantage of rst class cold storage technology with Panasonic ultra-low freezers.
Our reputation is built on superior performance and reliability with uniform environment, even with higher
ambient temperatures and frequent door openings.
Panasonic ultra-low freezers meet the toughest quality standards for performance, ergonomics and ROI.
We are proud to provide your samples with the ultimate and the most reliable protection, helping cutting-edge
research in critical elds like medicine, life sciences, pharmaceuticals and biotechnology.
Offer your samples the advantage of rst class cold storage technology with Panasonic ultra-low freezers.
Our reputation is built on superior performance and reliability with uniform environment, even with higher
ambient temperatures and frequent door openings.
Panasonic ultra-low freezers meet the toughest quality standards for performance, ergonomics and ROI.
We are proud to provide your samples with the ultimate and the most reliable protection, helping cutting-edge
research in critical elds like medicine, life sciences, pharmaceuticals and biotechnology.
Table of Contents
What to look for in an ULT freezer?
Find the right freezer for your needs.
Twin Guard® Freezers ( -86°C )
VIP® Freezers ( -86°C )
PRO Series Freezers ( -86°C )
Cryogenic Freezer ( -150°C )
Chest Freezers ( -80 / -86°C )
4
6
8
15
23
26
28
Environmentally Friendly Technology
Always a leader in environmentally friendly technology,
Panasonic refrigerators use commercially available HFC
refrigerants and CFC-free insulation.
• Compliance of RoHS, Restriction of
Hazardous Substance, on all units.
• Panasonic is committed to developing green
technologies that provide energy efciency
resulting in lower operational costs with less
impact on the environment.
VIP® Series ( -86°C )
MDF-U76VC-PA
Twin Guard® Series ( -86°C )
MDF-U700VXC-PA
PRO Series ( -86°C )
MDF-U7486SC-PA
1. Reliability
Panasonic products incorporate the latest applied theories and
ideas, refrigeration compressors, electronic components, robotic
manufacturing and economies-of-scale that directly benet the
customer. Furthermore, Panasonic products are extensively
tested to meet the toughest quality standards in the world for
performance, ergonomics and cost of ownership. Through the
vigorous application of our unique Vertical Component Integration,
Panasonic products offer tangible benets - from performance
and reliability to ergonomics and convenience -that no other
manufacturer can provide.
2. Performance
Panasonic Ultra low freezers offer the following advantages:
Rapid “pull down” – the time needed for your freezer
to return to set point after door openings to maintain
sample integrity
Best Temperature Uniformity that ensures all samples
are well protected.
What to look for in a freezer?What to look for in a freezer?
0 3 6 9
Panasonic
Brand B
Brand A
30%
faster
(Hours)
Panasonic Healthcare Company of North America
Surpasses the customer
preference of +/- 5°C*
UNIFORMITY
+5°C
-5°C
Pull down speed from room temp to -80°C
4
Based on internal validation
data tested at -80°C setpoint,
in an empty chamber with
23°C ambient temperature.
* The data may vary depending on the use, circumstances and optional accessories.
Validation documents can be provided for each serial number with an additional fee.
Chest Freezers ( -80 / 86°C )
MDF-794C0-PA
Cryogenic Freezer ( -150°C )
MDF-C2156VANC-PA
3. Energy Efciency
Panasonic ultra low freezers are insulated with high-performance
CFC-free and HCFC-free insulation and new composite
techniques to minimize energy consumption and lower operating
costs. Beyond highly competitive rst costs, Panasonic ultra-
low freezers demonstrate the lowest operating costs per cu.ft.
(liter) in the worldwide market.
4.Footprint / Capacity
Panasonic was the rst company to introduce vacuum insulation
panels to ultra-low temperature freezers. The Panasonic range of
VIP® freezers typically provide 25% more storage capacity for a
given oor area saving valuable laboratory space.
The Panasonic patented VIP® vacuum insulation panel thin-wall
composite is a high-efciency design that yields more interior
storage volume in a conventional freezer footprint.
Superior Footprint
Stainless steel shelf and insulated
inner-door combinations create
choices of interior compartments
that can be arranged for long-term,
low access biologicals or short-
term, frequently accessed material.
5
10
25
Consumed Power (kWh / day)
Panasonic Brand A Brand B
15
20 31%
more
efficient
up to
Ultra-Low and Cryogenic Freezers
5
Models: MDF-U700VXC, MDF-U500VXC,
MDF-U76VA, MDF-U76VC, MDF-U56VC,
MDF-U53VA, MDF-U33V.
Find the right freezer
for your needs.
Find the right freezer
for your needs.
Twin Guard®
Series Freezers
Two independent systems
offering double security for
your samples.
VIP® Series
Freezers
Most reliable freezer with
best performance and
maximum energy
savings.
Chest
Freezers
Energy efciency and
high performance cooling
with space saving
design.
PRO Series
Freezers
Optimum performance
under optimum
budget.
Cryogenic
Freezer
Reliable mechanical
refrigeration with
maximum storage
capacity.
Panasonic Healthcare Company of North America
7
Ultra-Low and Cryogenic Freezers
Model Number
Interior
Volume
Exterior Dimensions
(w x f-b x h)
Area Footprint,
Nominal
Insulation
Type
Fiberboard Boxes,
2” high (2ml) in
Panasonic Racks
Sample Vials,
2ml (2” box),
100-Cell Dividers
Electrical,
60Hz
MDF-U33V-PA 11.8 c u.f t.
333 L
26.4” x 34.1” x 73.2”
670 x 870 x 1860 mm
6.25 sq.ft.
0.58 m2VIP® 216 21,600 115V, AC, 15 amp
MDF-U53VA-PA 18.3 cu.ft.
519 L
30.3” x 34.4” x 78.3”
770 x 870 x 1990 mm
7.24 sq.ft.
0.67 m2VIP® 352 35,200 115V, AC, 20 amp
MDF-U56VC-PA 18.6 cu.ft.
526 L
30.3” x 34.4” x 78.3”
770 x 870 x 1990 mm
7.24 sq.ft.
0.67 m2VIP® PLUS 384 38,400 2 0 8 / 2 3 0 V, AC ,
15 amp
MDF-U76VC-PA 25.7 cu.ft.
728 L
39.8” x 34.4” x 78.3
1010 x 870 x 1990 mm
9.51 sq.ft.
0.88 m2VIP® PLUS 576 5 7, 6 0 0 2 0 8 / 2 3 0 V, A C ,
15 amp
MDF-U76VA-PA 25.7 cu.ft.
728 L
39.8” x 34.4” x 78.3
1010 x 870 x 1990 mm
9.51 sq.ft.
0.88 m2VIP® PLUS 576 5 7, 6 0 0 115V, AC, 20 amp
VIP® Series (-86ºC )
Model Number
Temperature
Range
Interior
Volume
Area Footprint
(nominal)
Insulation
Type
Storage
(2"/ 51 mm boxes)
Storage
(3"/ 76 mm boxes)
Storage
(2ml vials in boxes)
Electrical,
60Hz
MDF-U500VXC-PA -50ºC to -8C 18.3 cu.f t.
519 L
8.37 sq.ft.
0.67 m2VIP® PLUS 352 224 35,200 208/230V
NEMA 6-15
MDF-U700VXC-PA -50ºC to -86ºC 25.7 cu.ft.
728 L
9.51 sq.ft.
0.88 m2VIP® PLUS 576 384 5 7,6 0 0 208/230V
NEMA 6-15
Twin Guard® Series (-86ºC )
Model Number
Volume
(cu.ft.)
Exterior Dimensions
(w x f-b x h)
Insulation
Type
Storage
(2"/ 51 mm boxes)
Storage
(3"/ 76 mm boxes)
Storage
(2ml vials in boxes)
Voltage, Power
Connection
MDF-U5486SC-PA 17.1
483 L
35.0" x 34.4" x 78.3"
890 x 840 x 1990 mm Conventional 320 192 32,000 208/230V
NEMA 6-15
MDF-U7486SC-PA 23.5
668 L
44.5" x 34.4" x 78.3"
1130 x 870 x 1990 mm Conventional 480 288 48,660 208/230V
NEMA 6-15
PRO Series (-86ºC )
Model Number
Volume
(cu.ft.)
Exterior Dimensions
(w x f-b x h)
Insulation
Type
Storage
(2"/ 51 mm boxes)
Storage
(3"/ 76 mm boxes)
Storage
(2ml vials in boxes)
Voltage, Power
Connection
MDF-C2156VANC-PA 8.2
231 L
68.1" x 30.1" x 39.8"
1730 x 765 x 1010 mm VIP® PLUS 150 105 15,000 208/230V
NEMA 6-15
Cryogenic Freezer ( -150ºC )
Model Number
Volume
(cu.ft.)
Exterior Dimensions
(w x f-b x h)
Insulation
Type
Temperature
(°C)
Storage
(2"/ 51 mm boxes)
Storage
(3"/ 76 mm boxes)
Storage
(2ml vials in boxes)
Voltage, Power
Connection
MDF-C8V1-PA 3.0
84 L
21.6" x 27.0" x 37.2"
550 x 685 x 945 mm VIP® PLUS -80°C 42 30 4,200 115V
NEMA 5-15
MDF-594C-PA 17. 2
487 L
79.1" x 30.3" x 42.1"
2010 x 770 x 1070 mm Conventional -86°C 351 243 3 5,10 0 208/230V
NEMA 6-15
MDF-794C-PA 24.8
701 L
101.2" x 30.3" x 42.1"
2570 x 770 x 1070 mm Conventional -86°C 507 351 50,700 208/230V
NEMA 6-15
Chest Freezers (-86ºC / -80ºC )
What makes Twin Guard® Series
a product you can trust?
Twin Guard® Series
MDF-U700VXC-PA
Twin Guard® Series
MDF-U700VXC-PA
MDF-U500VXC-PA
Security Now
Comes with Two.
Security Now
Comes with Two.
Innovative Design:
Two independent systems allowing the unit to
run continuously at -65°C in the unlikely event
of one compressor failure.
Patented VIP® PLUS Vacuum Panel:
Uniform temperatures with energy efcient
and space efcient refrigeration.
Ergonomic Design:
One-handed outer and inner door latches
and compressors to minimize sound.
9
Ultra-Low and Cryogenic Freezers
The Panasonic Twin Guard® Series satises the industry demand
for safe, long-term storage for the most high-valued materials.
Two independent refrigeration systems, combined with optional
liquid nitrogen or liquid CO2 back-up systems, offer a circle of
protection unmatched in the marketplace. Developed for use with
conventional inventory racks and boxes, the Twin Guard® Series
is ideal for storage of sensitive stem cells, embryos, cell lines, and
other rare specimens.
The Most Dependable
Ultra-Low Freezers for
Long-Term Storage
The Most Dependable
Ultra-Low Freezers for
Long-Term Storage
Ultimate
Protection
Ultimate
Protection
The efcient ultra-low cooling is
achieved through two independent
evaporator circuits surrounding
the interior chamber.
Chamber temp. (°C)
Pull-up while a power failure
Single compressor operation
(kept at approx. -65°C or lower
depending on load)
Normal cycle operation (-80°C setting)
20
0
-20
-40
-60
-80
-100 0 1 2 3 4 5 6 7 8 9 10 11 12
(hour)
Chamber temp. (°C)
Central air temp. in cabinet
Ambient temp. 30°C, No-Load
20
0
40
-20
-40
-60
-80
-100 0 1 2 3 4 5 6 7 8 9 10 11 12
(hour)
Pull-up characteristics during power failure
Pull-down charateristics
Performance
& Recovery
ULTRA-LOW
CRITICAL LOST
-86°C-86°C
-65°C
23°C
KEY
SINGLE COMPRESSOR
SYSTEM FAILURE
U LTR A -LOW
SAMPLE LOSS
SINGLE COMPRESSOR
SYSTEM
SECOND COMPRESSOR
SYSTEM
Traditional Freezer
Second independent system kicks in to
maintain ultra-low temperatures in the
event of a failure
Freezer relies on a single system, causing a
complete shut-down when failure occurs
Twin Guard® Series
Give your samples the ultimate protection
of patented Twin Guard® technology
two independent systems can
individually sustain ultra-low temperatures
in the event of a failure, so you can rest
easy knowing your valuable work is in
good hands.
10
Panasonic Healthcare Company of North America
??
The Panasonic MDF-U500VXC and MDF-U700VXC Twin Guard® Series ultra-low freezers are designed for -86°C
storage of high-value biologicals. Ideal for critical material storage in repositories, highly secure BSL 3/4 labs, GMP
facilities, hospitals, clinics and medical research facilities. The Twin Guard® Series introduces the concept of dual,
independent, autocascade refrigeration systems contained within a single cabinet.
What is
Twin Guard®
Technology
What is
Twin Guard®
Technology
??
4
5
6
7
8
10
The Panasonic ergonomic
design features a high-
security Easy-In / Easy-Out
door latch designed for
simplicity and safety. Also
allows for one handed
operation.
2
Barrier Film
VIP® PLUS
Interior
Rigid foamed
polyurethane
1
93
A vacuum relief
valve is mounted
in the left wall.
12
11
1. Panasonic patented VIP® PLUS vacuum
insulation panel cabinet construction for
high insulating value and increased interior
volume in the same footprint.
2. Easy-In/Easy-Out door latch for smooth,
one-handed operation, positive seal against
gasket.
3. Integrated, microprocessor-based control
system and LCD display information center
includes comprehensive set-point, alarm,
monitoring, diagnostic and communications
functions.
4. Insulated, sealed, and gasketed inner doors
seal inside to offer additional protection,
improve uniformity.
5. New air-cooled super condenser energy
transfer technology maintains optimum
condenser air ow and eliminates the need
for an air lter or reducing the requirement
for periodic maintenance.
6. High impact, recessed casters and leveling
feet simplify installation.
7. Cool Safe compressors are specically
designed for one-compressor, autocascade
applications.
8. Twin Guard® Series redundant refrigeration
-86° Dual Cool circuits offer two systems in
one, each providing back-up for the other,
or working together for fast recovery or
energy savings
9. Multiple access ports permit insertion
of independent probes, instrumentation
or liquid nitrogen or liquid CO2 back-up
injectors.
10. CFC-refrigerants are highly efcient,
environmentally safe, non-ozone depleting.
11. A vacuum relief valve is mounted in the left
wall to ensure easy access to chamber
following door closure.
12. Standard remote alarm contacts and
optional communication port available.
11
Ultra-Low and Cryogenic Freezers
www.TwinGuardSeries.com
?
WHAT IS
TWIN GUARD®
TECHNOLOGY
COMPRESSOR
FAILURE
COMPRESSOR
FAILURE
-86°C -65°C
Panasonic
Twin Guard®
freezer
Second independent
compressor system kicks
in to maintain ultra-low
temperatures in the event
of a failure. Temperature
remains at 65°C.
Simply put, a compressor is what runs
your freezer. It’s the heart of the whole
system, keeping your freezer at ultra-
low temperatures. The compressor is
tied to refrigeration coils that run
throughout the unit to maintain those
even, sub-zero temperatures.
With Panasonic’s patented
Twin Guard technology,
2 compressors are
completely separated from
one another, with no
reliance on the other to
operate. So if one of them
fails, the other is unaffected
and your freezer will keep
chugging along at ultra-low
temperatures.
Panasonic
So, what’s a
compressor?
23°C
Traditional
freezer
Freezer relies on a single
compressor system,
causing a complete
shut-down when failure
occurs. Temperature
quickly rises to room
temperature.
-86°C
Compressors are
traditionally made up of two
parts: a high stage and low
stage. These parts rely on
one another to operate, so
if there is a problem with
either part, the entire
system shuts down.
Traditional
A B
Traditional
freezer
Freezer relies on a single
compressor system,
causing a complete
shut-down when failure
occurs. Temperature
quickly rises to room
temperature.
Panasonic
Twin Guard®
freezer
Second independent
compressor system kicks
in to maintain ultra-low
temperatures in the event
of a failure. Temperature
remains at -65°C.
www.TwinGuardSeries.com
?
WHAT IS
TWIN GUARD®
TECHNOLOGY
COMPRESSOR
FAILURE
COMPRESSOR
FAILURE
-86°C -65°C
Panasonic
Twin Guard®
freezer
Second independent
compressor system kicks
in to maintain ultra-low
temperatures in the event
of a failure. Temperature
remains at 65°C.
Simply put, a compressor is what runs
your freezer. It’s the heart of the whole
system, keeping your freezer at ultra-
low temperatures. The compressor is
tied to refrigeration coils that run
throughout the unit to maintain those
even, sub-zero temperatures.
With Panasonic’s patented
Twin Guard technology,
2 compressors are
completely separated from
one another, with no
reliance on the other to
operate. So if one of them
fails, the other is unaffected
and your freezer will keep
chugging along at ultra-low
temperatures.
Panasonic
So, what’s a
compressor?
23°C
Traditional
freezer
Freezer relies on a single
compressor system,
causing a complete
shut-down when failure
occurs. Temperature
quickly rises to room
temperature.
-86°C
Compressors are
traditionally made up of two
parts: a high stage and low
stage. These parts rely on
one another to operate, so
if there is a problem with
either part, the entire
system shuts down.
Traditional
A B
So, what is a
compressor?
Simply put, a compressor is what runs
your freezer. It’s the heart of the whole
system, keeping your freezer at ultra-low
temperatures. The compressor is tied
to refrigeration coils that run throughout
the unit to maintain those even, sub-zero
temperatures.
A B
Traditional Panasonic
Compressors are traditionally made up
of two parts: a high stage and low stage.
These parts rely on one another to operate,
so if there is a problem with either part, the
entire system shuts down.
With Panasonic’s patented Twin
Guard technology, 2 compressors are
completely separated from one another,
with no reliance on the other to operate.
So if one of them fails, the other is
unaffected and your freezer will keep
operating at ultra-low temperatures.
Sample Security, Alarms & MonitoringSample Security, Alarms & Monitoring
The Twin Guard® series is managed by an integrated microprocessor controller with LCD information center to simplify all freezer functions.
Panasonic Twin Guard® series freezers offer a large storage capacity of 576 2" boxes,
while maintaining a small footprint with reduced energy usage. This leads to a lower energy requirement per box
stored, saving you money in ongoing operational costs.
Optimal Capacity & FootprintOptimal Capacity & Footprint
Model Number
Temperature
Range
Interior
Volume
Area Footprint
(nominal)
Storage
(2"/ 51 mm boxes)
Storage
(3"/76 mm boxes)
Storage
(2ml vials in boxes)
Electrical,
60Hz
MDF-U500VXC-PA -5C to -8C 18.3 cu.f t.
519 L
8.37 sq.ft.
0.67 m2352 224 35,200 208/230V
NEMA 6-15
MDF-U700VXC-PA -5C to -8C 25.7 cu.ft.
728 L
9.51 sq.ft.
0.88 m2576 384 5 7,6 0 0 208/230V
NEMA 6-15
Alarm & Safety Features Events Visual Audible Signal to Alarm Contact
Status Alert
Inefcient system operation,
abnormal ambient, low voltage
or heavy loading.
Notication of error on
graphical display
None None
High Temperature
(Up to +40°C)*
Interior chamber cools beyond
high temp set-point Intermittent tone. Time delay of
15 minutes after reaching alarm
set-point avoids false alarms.
Intermittent tone.
Yes
Low Temperature
(Up to -40°C)*
Interior chamber warms
beyond low temp set-point Yes
Power Failure Loss of power Intermittent Tone Yes
Control Temperature
Sensor Failure
Sensor probe disconnect
short circuit or failure Solid Tone Yes
Door Alarm Door open Notication of error on
graphical display
Solid tone sounds after
2 minutes Yes
*Extended range is important for GxP applications to reduce potential incident event reporting. The integrated microprocessor control aggregates information from the entire system
and compares to normal or set-point values. Out-of-compliance events are announced by visual and audible warnings, and remote alarm when connected to an external system.
Digital LCD display with
alphanumeric information
Display contrast
adjustment
Positive feedback tactile
input buttons
Positive feedback tactile
entry and function keys
Visual alarm
indicator
Menu call
button
Message display
Pop-up menu
Buzzer silence
temporarily mutes
audible alarm.
All performance attributes are
displayed on a large, visually
intuitive alphanumeric display.
Internal temperature log les
are expressed in graphical
form over time.
Out-of-compliance events
are announced by visual and
audible warnings. Error codes
quickly identify problem sources
and permit fast diagnosis and
remediation.
Panasonic Healthcare Company of North America
Audible
alarm
12
Technical Specications Technical Specications
Description
Model Number MDF-U500VXC-PA MDF-U700VXC-PA
Temperature Set-point Range -50°C to -86°C
Design Cooling Performance
-86 Dual°Cool (both compressors) -86°C (ambient temperature 30°C)
Single System Cooling Performance (Indenite) -65°C (ambient temperature 30°C)
Cabinet Design and Construction
Cabinet Insulation Patented VIP® PLUS composite wall
Exterior Dimensions (w x f-b x h) 35.5” x 40” x 78.3”
770 x 870 x 1990 mm
42.5” x 40” x 79.1”
1010 x 870 x 2010 mm
Interior Dimensions (w x f-b x h) 25.6” x 23.6” x 54.3”
630 x 600 x 1380 mm
34.3” x 23.6” x 55.1
870 x 600 x 1400 mm
Volume 18.3 cu.ft.
519 liters
25.7 cu.ft.
728 liters
Shelves 3, adjustable, stainless steel (4 compartments)
Access Port Diameter = 0.5”/17mm; 3 locations
Vacuum Release Port Standard, Manual
Refrigeration System
Refrigeration Technique Panasonic -86 Dual°Cool independent, redundant
cooling systems with automatic switchover
Compressors Per system: Single, hermetically-sealed 1100W
Panasonic Cool Safe compressor, air-cooled
Refrigerant Environmentally safe HFC refrigerant
Air Exchange Dual condenser fans with particulate trap; no lters are required
Cycle Options Standard or energy-saving EcoMode operation
Controls, Alarm, Monitoring
Controller Panasonic microprocessor-based, door-mounted
control with graphical LCD information center
Data Management Internal data log with log le memory
Communications Data can be transmitted via RS485, optional 4-20 mA
Alarms High/Low temperature, door ajar, power failure, remote alarm contact,
part replacement notication, fan motor lock, individual cooling circuit check
Remote Alarm Contacts Standard; normally open or normally closed, dry contacts
Electrical 208V-230V, AC, 60Hz, 1 phase, NEMA 6-15, 15 amp
separate breaker recommended
ECO mode operation image
Pull down
Temp.
Comp A
Comp B
Stable temperature
NORMAL mode operation image
Pull down
Temp.
Comp A
Comp B
Stable temperature
This chart shows the repeatable cycling wave form of normal mode vs. eco mode.
Normal mode is for strict GMP applications.
2 compressors are turned ON/OFF at same time
2 compressors and fan motor for each are independently controlled by SV and read AT.
Chamber
Comp A
Comp B
temp T12 on T12 o
Normal
Normal
Chamber
Comp A
Comp B
temp
T12 on T12 o
T2 on T2 o
Chamber
Comp A
Comp B
temp
T onT1 o T12 on T2 oT1 2 on
ECO mode
ECO mode
Ultra-Low and Cryogenic Freezers
The Panasonic Twin Guard® Series Freezer can be set for Normal or
EcoMode operation. EcoMode establishes an overlapping cycle to
reduce energy consumption.
13
Eco Mode vs. Normal ModeEco Mode vs. Normal Mode
14
MDF-U500VXC
MDF-U700VXC
34.3” (870)
21.0” (533)
Dimensional
Drawings
Dimensional
Drawings
Panasonic Healthcare Company of North America
Leading Performance
with Greater Energy
Savings.
Leading Performance
with Greater Energy
Savings.
VIP® Series
MDF-U76VC-PA
MDF-U56VC-PA
What makes VIP® Series so green?
Thinking Green: Environmentally friendly refrigerants,
RoHS compliant and low-noise operation.
What makes VIP®
Freezers so Reliable?
What makes VIP®
Freezers so Reliable?
Panasonic VIP® ultra-low freezers represent the industry’s most complete combination of refrigeration,
control, alarm, monitoring and accessibility for product safety at -86°C. Ideal for material storage in
repositories, hospitals, clinics and medical research facilities, the VIP® Series freezers are designed to
reduce energy consumption and offer optimal performance.
Uniformity
you can trust
Combination of patented VIP® plus
vacuum insulation panel with Panasonic
designed compressors specic to ultra-low
applications, result in unmatched uniformity,
that surpasses the strictest protocols, no
matter where your samples are stored
within the unit.
Performance
Panasonic compressors employs a unique
orientation of components that increases
compressor longevity and refrigeration
capacity while reducing operating pressure
and discharge temperatures – a key
component that yields better reliability.
Validated
temperature
recovery
Increased reserve cooling capacity improves
temperature recovery after door openings
Energy
Savings
Energy Efcient
Cascade Cooling
Panasonic cascade refrigeration system and
the new improvements in the heat exchanger
design drastically increase the efciency of
the entire system. The end result is less ener-
gy consumption, while improving the overall
efciency and reliability of the freezer.
0 3 6 9
Panasonic
Brand B
Brand A
30%
faster
(Hours)
Pull down speed from room
temperature to -80°C
Panasonic Healthcare Company of North America
5
10
25
Consumed Power (kWh / day)
Panasonic Brand A Brand B
15
20 31%
more
efficient
up to
16
Surpasses the customer
preference of +/- 5°C*
UNIFORMITY
+5°C
-5°C
Based on internal validation data tested
at -80°C setpoint, in an empty chamber
with 23°C ambient temperature.
* The data may vary depending on the use, circumstances and optional accessories.
Validation documents can be provided for each serial number with an additional fee.
Low Stage Compressor
Compresses and pumps
refrigerant through the low
stage circuit.
Oil Heat Exchanger
Panasonic exclusive high stage
refrigerant passes through both
compressor oil sumps to cool
lubricating oil resulting in high-stage
refrigerant being used to increase the
durability of the compressors.
Low Stage Refrigerant
Commonly available
worldwide, R508.
Industry Standard.
Main Condenser and
Motor/Fan Assembly
Panasonic’s exclusive triple
pass forced air condenser
increases overall system
efciency by providing
maximum surface area for
heat rejection.
Instrumentation (Not Shown)
Temperature and pressure sensors throughout the
high and low stage circuits transmit information to the
Panasonic ‘Status Alert’ central controller for operation,
monitoring, interpretation and component protection.
High Stage Refrigerant
Commonly available worldwide.
Selected for optimum cooling
performance in compliance
with international environmental
protection laws.
NEW! High Efciency
Heat Exchanger
Low stage capillary tube
heat exchanger provides
optimum heat transfer
between high and low
temperature points in
the low stage leading to
greater energy efciency.
VIP® Series -86°C Freezer
Energy Efcient Cascade
Cooling System
VIP® Series -86°C Freezer
Energy Efcient Cascade
Cooling System
Ultra-Low and Cryogenic Freezers
17
A. Inventory Rack Systems: Panasonic freezers are available with a
variety of inventory racks to meet specic applications. Freezers can
be ordered with full-load inventory systems by selecting one catalog
number.
B. The Digital Temperature Recorder: The recorder mounts on the
cabinet door and is programmable to capture and store non-corrutible
data points for downloading to an independent data management
system to meet criteria outlined in U.S. FDA 21CFR Part II directives.
An independent probe is placed in the interior chamber.
C. Touch-Screen Display: A touch-screen digital display with full color
graphing capabilities of your complete temperature history is at your
ngertips with scrolling and zoom. The touch screen monitor ts on the
front panel of your Panasonic equipment either in place of the recorder
or at eye level and is designed to work without software. Software is
optionally available if you wish to download your data to PC via USB or
ash memory for archiving to meet criteria outlined in U.S. FDA 21CFR
Part 11 directives.
D. Circular Recorder, Strip Chart Recorder and
Recorder Mounting Bracket
E. CO2 Backup System and LN2 Backup System
VIP®
Features
VIP®
Features
Optional
Accessories
Optional
Accessories
A
ED
B C
3
4
56
7
8
9
2
The Panasonic ergonomic design features
a high-security Easy-In/Easy-Out door latch
designed for simplicity and safety. Also
allows for one handed operation.
1
10
1. Easy-In/Easy-Out door latch for smooth, one-
handed operation, positive seal against gasket.
Padlock provision standard.
2. Integrated, microprocessor-based control
system and LED display includes comprehensive
set-point, alarm, monitoring, diagnostic and
communications functions.
3. Insulated and gasketed inner doors seal inside to
offer additional protection and improve uniformity.
Inner door latches are standard. Doors can be
easily removed for defrosting.
4. Front access to washable, electrostatic condenser
lter for routine condenser air lter cleaning.
5. High impact, recessed casters and leveling feet
simplify installation.
6. New generation Panasonic designed Cool Safe
compressors are specically designed for low
temperature applications.
7. Multiple access ports permit insertion of
independent probes, instrumentation or liquid N2
or liquid CO2 back-up injectors.
8. Commercially available HFC-refrigerants are highly
efcient, environmentally safe and non-ozone
depleting.
9. Remote alarm contacts and optional
communication port available; see Accessories.
10. Vacuum relief valve (Available on the MDF-U56VC,
MDF-U76VC, and MDF-U76VA)
18
Panasonic Healthcare Company of North America
Water Cooled Condenser Description
Water Pressure & Temperature Maximum Water Pressure: 150psig, Minimum Water Pressure Differential: 15psig, Maximum Water Temperature: 30°C
Connections Typically ½” compression ttings on inlet and outlet but can be customized for customer needs
Required Water Flow Rate
(Maximum) Tower Water: 11.4 liters per minute
Installation Qualied technician required at time of installation to balance water ow requirements. Efciencies can be easily obtained regard-
ing water usage by balancing the water ow to optimum usage and freezer efciency dependent upon the specic site installation
Accessory Description Catalog Number
Half Inner Door Set of two; Field Installed; replaces half inner door;
for a four-door conguration order two sets
MDF-5ID-PW (MDF-U53VA), MDF-5ID1-PW (MDFU-56VC),
MDF-7ID1-PW (MDF-U76VC / MDF-U76VA)
Digital Temperature Recorder Auxiliary Data Logger HAMSTERDT2
Liquid CO2 Back-Up System Auxiliary back-up in event of power failure CVK-UB2(I)-PW
Liquid N2 Back-Up System Auxiliary back-up in event of power failure CVK-UBN2-PW
Chart Recorder Circular Chart Temperature Recorder, 7 Day MTR-C954
Chart Paper 6” Diameter, 7 Day Chart C7100386REV
Replacement Pen, Red / Blue Felt tip pens, 6 per pack R252 / R253
Digital Touch Panel Recorder Programmable digital temperature recorder FT560SN
Data Logging Software For use with touch panel recorder A016
21 CFR Part 11 Compliant Software For use with touch panel recorder A026
Energy PerformanceEnergy Performance
Options & AccessoriesOptions & Accessories
VIP® freezers help the environment
by reducing carbon footprint.
Panasonic freezers emit less heat into the
laboratory, minimizing air conditioning costs.
Panasonic VIP® freezers
provide reduced operational
cost for highly efcient
sample storage.
Less Emission
Operating Cost
More
Efcient
0
1
2
3
4
5
4.97
2.99
4.33
Pounds / Box Capacity
Annual CO2 Emissions
by Box Capacity
Panasonic freezers help the environment
by reducing carbon footprint.
40%
lower
emissions
up to
Brand A
Brand B
Panasonic
MDF-U76VC
Total annual operating cost
for operation and cooling by capacity
Cost is an average for operating freezer
including cost to remove heat from the room
generated by the freezer.
$0
$1
$2
$3
$4
2.64
1.83
3.04
Dollars / Box Capacity
40%
less cost
up to
0
.01
.02
.03
.04 .043
.026
.038
KW / day / box capacity
Power Consumption By Capacity
(KW/day/box capacity)
Panasonic freezers provide reduced
operational cost for highly efficient
sample storage.*
39%
more
efficient
up to
Ultra-Low and Cryogenic Freezers
19
The superior energy efciency of Panasonic VIP® Series Ultra-Low Freezers leads to signicant annual cost savings. Lower kW usage
combined with lower heat rejection leads to savings on freezer operation costs plus associated HVAC costs to remove heat from the room
generated by the freezer. With an industry-leading capacity of up to 576 2” boxes, the energy-saving advantages of this efcient Panasonic
system extend to lower per-unit storage costs regardless of the preferred inventory conguration.
The concept of High Density Storage is enabled by advances in Panasonic Cool Safe compressor design. The cost per 2” box of interior
storage space is signicantly lower in a Panasonic ultra-low freezer, generating immediate return on investment based on rst costs,
operating costs and maintenance costs over time.
1 Year 5 Years
Brand A
Brand B
$ Savings - Per Unit
Operating Cost Savings per Unit - 1/5/10 Years
Panasonic MDF-U76VC vs. Brand A and B
0
500
1000
1500
2000
2500
$146 $248
$1241
$730
$547 $693
$795
Dollars
2 Years1 Year
Total Operating Cost of 1 Unit
0
1000
2000
3000
4000
31%
less cost
annually
up to
$547 $693
$795
Dollars
2 Years1 Year
Total Operating Cost of 1 Unit
0
1000
2000
3000
4000
$69
$69
$69
$
3
3
3
$69
$69
$
3
3
$54
$54
$5
$
7
7
$54
$54
7
7
31%
less cost
annually
up to
$547 $693
$795
Dollars
2 Years1 Year
Total Operating Cost of 1 Unit
0
1000
2000
3000
4000
$69
$69
$
3
3
$54
$54
$
7
7
31%
less cost
annually
up to
$547 $693
$795
$3467
$2737
$3978
Dollars
2 Years1 Year 3 Years4 Years5 Years
Total Operating Cost of 1 Unit
0
1000
2000
3000
4000
Brand A
Brand B
Panasonic
MDF-U76VC
31%
less cost
annually
up to
$547 $693
$795
$3467
$2737
$3978
Dollars
2 Years1 Year 3 Years4 Years5 Years
Total Operating Cost of 1 Unit
0
1000
2000
3000
4000
$34
$34
67
67
$34
34
67
67
0
0
0
0
0
0
0
0
$69
$69
3
3
$69
$69
3
3
$
$69
$69
$
3
3
$$69
$
3
$
$
$
$
$
$
$54
$54
7
7
$54
$54
7
7
$5
$54
$54
$
7
$54
$54
77
Brand A
Brand B
Panasonic
MDF-U76VC
31%
less cost
annually
up to
$547 $693
$795
$3467
$2737
$3978
Dollars
2 Years1 Year 3 Years4 Years5 Years
Total Operating Cost of 1 Unit
0
1000
2000
3000
4000
$34
$34
67
67
$69
$69
$
3
3
$54
$54
$
7
7
Brand A
Brand B
Panasonic
MDF-U76VC
31%
less cost
annually
up to
$547 $693
$795
$3467
$2737
$3978
Dollars
2 Years1 Year 3 Years4 Years5 Years
Total Operating Cost of 1 Unit
0
1000
2000
3000
4000
$34
$34
67
67
$69
$69
$
3
3
$54
$54
$
7
7
Brand A
Brand B
Panasonic
MDF-U76VC
31%
less cost
annually
up to
0
5
10
15
20
25
30
21%
31.1%
% Savings –Panasonic MDF-U76VC
vs. Brand Avs. Brand B
Operating Cost
Savings Percentage
Operating AnalysisOperating Analysis
The Panasonic microprocessor control
system is secure, easy to use and
comprehensive. Set-point, alarm parameters
and self-diagnostic functions are accessed
through a tamper-resistant keypad protocol.
Control inputs are managed with convenient
push buttons on a unitized, sealed control
overlay. The panel is door-mounted and
angled for easy access.
Sample Security,
Alarms & Monitoring
Sample Security,
Alarms & Monitoring
Panasonic Healthcare Company of North America
20
Alarm indicator lamp glows when freezer is
in alarm condition; alarm ringback is factory
set for 30 minutes, adjustable in 10 minute
increments from 10 to 60 minutes.
Panasonic exclusive Ni-MH battery powers
control memory and alarm functions during
power failure.
Status alert function uses predictive intelligence to
determine if freezer is operating within specications
under existing environmental conditions.
Filter indicator lamp glows
when electrostatic lter
requires removal for cleaning.
Digital display defaults to actual
chamber temperature. Display
mode changes when set-point,
alarm parameters, programming
and diagnostic functions are
performed.
Adjustable compressor start-
up delay sequence delays
re-start after building power
failure; allows facility power
to reach equilibrium to permit
smooth compressor start-up.
Buzzer silence
temporarily mutes
audible alarm. Alarm test veries readiness
of alarm function and Ni-MH
battery charge.
Audible alarm.
Door alarm indicator has
2 minute delay until
audible alarm activates;
delay time is adjustable.
Set-point entry
advances digital to next
value from 0 to 9.
Set-point entry advances
digital display to next
position.
Adjustable alarm set-points are factory set 10ºC above and
below set-point. Alarm parameters are adjustable by pressing
up or down arrow keys and following the prompt.
Press to set temperature; set button is also
used for other diagnostic functions.
Optimal Capacity & Footprint Optimal Capacity & Footprint
The concept of High Density Storage is enabled by advances in Panasonic Cool Safe compressor design. The cost
per 2” box of interior storage space is signicantly lower in a Panasonic VIP® ultra-low freezer, generating immediate return on investment
based on rst costs, operating costs and maintenance costs over time.
Description
Model Number MDF-U33V-PA MDF-U53VA-PA MDF-U56VC-PA MDF-U76VC-PA MDF-U76VA-PA
Rack Positions, Standard Conguration
3 Columns
4 Rows
4 Columns
4 Rows
4 Columns
4 Rows
6 Columns
4 Rows
6 Columns
4 Rows
Fiberboard Boxes, 2” high (2ml) in Racks 216 352 384 576 576
Sample Vials, 2ml (2” box), 100-Cell Dividers 21,600 35,200 38,400 57, 6 0 0 5 7,6 0 0
Fiberboard Boxes, 3” high (4ml) in Racks 144 224 256 360 384
Sample Vials, 4ml (3” box), 100-Cell Dividers 14,400 22,400 25,600 38,400 38,400
Standard Microplate with Foil Tape, in Racks 1,298 2,112 2,112 3,456 3,456
Standard Microplate with Cover Lid, in Racks 1,008 1,632 1,632 2,596 2,596
Fully Loaded Inventory Systems Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Maximum Vial Capacity
Includes full quantity of storage racks, boxes and dividers
Sliding Drawer Inventory Racks
2” High Boxes (2ml Sample) 100-Cell Divider
(6) GRD442A
(6) GRD452SS
(8) GRD462SS
(8) GRD452SS
(8) GRD443A
(8) GRD452SS (24) GRD462SS (24) GRD462SS
Sliding Drawer Inventory Racks,
3” High Boxes (4ml Sample) 100-Cell Divider (12) GRD433A (8) GRD443A
(8) GRD433A
(8) GRD443A
(8) GRD452SS
(18) GRD443A
(6) GRD433A (24) GRD443A
Individual Storage Rack System Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
Sliding Drawer Sample Racks for Fiberboard Storage Boxes
(Boxes Not Included)
Sliding Drawer Rack, for 2” high (2ml sample)
boxes; holds 6 boxes high x 4 boxes deep
GRF462SS
Capacity 8
GRF462SS
Capacity 16
GRF462SS
Capacity 24
GRF462SS
Capacity 24
Sliding Drawer Rack, for 2” high (2ml sample)
boxes; holds 5 boxes high x 4 boxes deep
GRD452SS
Capacity 6
GRD452SS
Capacity 8
Sliding Drawer Rack, for 2” high (2ml sample)
boxes; holds 4 boxes high x 4 boxes deep
GRD442A
Capacity 6
Sliding Drawer Rack, for 3” high (4ml sample)
boxes; holds 4 boxes high x 4 boxes deep
GRD443A
Capacity 8
GRD443A
Capacity 8
GRD443A
Capacity 24
G R D 4 4 3 A
Capacity 24
Sliding Drawer Rack, for 3” high (4ml sample)
boxes; holds 3 boxes high x 4 boxes deep
GRD433A
Capacity 12
GRD433A
Capacity 8
GRD433A
Capacity 8
Standard Cellular Inventory Racks for Fiberboard Storage Boxes
(Boxes Not Included)
Inventory Rack for 2” (2ml sample) boxes;
6 boxes high x 4 boxes deep
GRF462SS
Capacity 8
GRF462SS
Capacity 16
GRF462SS
Capacity 24
GRF462SS
Capacity 24
Inventory Rack for 2” (2ml sample) boxes;
5 boxes high x 4 boxes deep
GRF452SS
Capacity 6
GRF452SS
Capacity 8
Inventory Rack for 2” (2ml sample) boxes;
4 boxes high x 4 boxes deep
GRF442A
Capacity 6
Inventory Rack for 3” (4ml sample) boxes;
4 boxes high x 4 boxes deep
GRF443A
Capacity 8
GRF443A
Capacity 8
GRF443A
Capacity 24
GRF443A
Capacity 24
Inventory Rack for 3” (4ml sample) boxes;
3 boxes high x 4 boxes deep
GRF433A
Capacity 12
GRF433A
Capacity 8
GRF433A
Capacity 8
Maximum Sample Storage Capacity
Ultra-Low and Cryogenic Freezers
21
Description
Model Number MDF-U33V-PA MDF-U53VA-PA MDF-U56VC-PA MDF-U76VC-PA MDF-U76VA-PA
Interior Volume 11. 8 c u.f t.
333 L
18.3 cu.ft.
519 L
18.6 cu.ft.
526 L
25.7 cu.ft.
728 L
25.7 cu.ft.
728 L
Area Footprint, Nominal 6.25 sq.ft.
0.58 m2
7.24 sq.ft.
0.67 m2
7.24 sq.ft.
0.67 m2
9.51 sq.ft.
0.88 m2
9.51 sq.ft.
0.88 m2
Electrical, 60 Hz 115V, AC, 15 amp 115V, AC, 20 amp 208/230V, AC, 15 amp 208/230V, AC, 15 amp 115V, AC, 20 amp
Patented VIP® Construction
Insulated Inner Door Steel-framed, high impact plastic with foam-in place insulation
Inner Door Conguration 22 (4 optional) 2 (4 optional) 2 (4 optional) 2 (4 optional)
Door Gaskets Multi-point compression gaskets
Condenser Filter, Easy Cleaning Electrostatic lter standard, front accessible for easy access, no tools required
Rounded Interior Corners Simplify Cleaning
Shelf Brackets Incrementally adjustable
Casters High-impact 4 with leveling feet
Seismic Restraints Standard; hard connection to facility wall
Access Ports Multiple ports allow use of injection tubes, probes, leads, instrumentation
Dimensions & Weight
Interior (w x f-b x h) 19.3” x 23.6” x 44.9
490 x 600 x 1140 mm
24.8” x 23.6” x 54.3”
630 x 600 x 1380 mm
24.8” x 23.6” x 55.1”
630 x 600 x 1400 mm
34.2” x 23.6” x 55.1
870 x 600 x 1400 mm
34.2” x 23.6” x 55.1
870 x 600 x 1400 mm
Exterior (w x f-b x h) 26.4” x 34.1” x 73.2
670 x 870 x 1860 mm
30.3” x 34.4” x 78.3
770 x 870 x 1990 mm
30.3” x 34.4” x 78.3
770 x 870 x 1990 mm
39.8” x 34.4” x 78.3”
1010 x 870 x 1990 mm
39.8” x 34.4” x 78.3”
1010 x 870 x 1990 mm
Net Weight, Empty 562 lbs
255 kg
660 lbs
290 kg
672 lbs
305 kg
805 lbs
365 kg
820 lbs
373 kg
Refrigeration System, HFC Refrigerants, Panasonic Cool Safe High Performance Compressors
High Stage 1 HP ½ HP 1 HP 1 HP 1 HP
Low Stage ¾ HP 1 HP 1½ HP 1½ HP 1½ HP
Voltage Booster, Built-In Not Available Not Available Standard Standard Not Applicable
Sound Abatement Standard Standard Standard Standard Standard
Refrigeration System, HFC Refrigerants, Panasonic Cool Safe High Performance Compressors
Power, AC, 1 Phase 115V 115V 208-230V 208-230V 115V
Recommended Breaker, Dedicated 15 amp 20 amp 15 amp 15 amp 20 amp
NEMA Plug / Receptacle 5-15P/5-15R 5-20P/5-20R 6-15P/6 -15R 6-15P/6-15R 5-20P/5-20R
Technical Specications Technical Specications
Panasonic Healthcare Company of North America
22
PRO Series
MDF-U7486SC-PA
PRO Series
MDF-U7486SC-PA
Insulated for Reduced
Carbon Footprint
What makes PRO Series freezers so efcient?
Insulated for Reduced
Carbon Footprint
What makes PRO Series freezers so efcient?
Thinking Green: Environmentally friendly refrigerants,
RoHS compliant and low-noise operation.
MDF-U5486SC-PA
Panasonic’s conventionally insulated PRO Series ultra-low freezers provide energy savings while minimizing
carbon footprint throughout the laboratory without compromising performance. It also maintains the internal
temperatures as low as -86°C. All models use Panasonic-designed compressors for ultra-low temperature
applications. Manufactured with foam-in-place insulation to maximize interior temperature uniformity, they
are ideally suited for use in hospitals and laboratories for long-term preservation and storage of specimens
and components, as well as material testing.
1. The insulation used in Panasonic’s PRO
Series ultra-low temperature freezers is high
density rigid, foamed-in-place polyurethane.
This design prevents the insulation layers from
distortion and cracking that might occur due to
temperature differences inside and out.
2. Ergonomic one handed Easy-In / Easy Out
outer door latch will accept a padlock.
3. Microprocessor-based controller.
4. Remote alarm contacts can be connected to
independent monitoring system.
5. Insulated sealing inner doors help maintain
interior temperature during routine openings.
Two inner doors are standard.
6. “Eagle Beak” inner door latches.
7. Easy front access to washable, electrostatic
condenser lter for routine condenser air lter
cleaning.
8. High impact recessed casters simplify
installation.
9. Panasonic designed compressors specically
designed for low temperature use offer
maximum reliability.
10. Multiple access ports permit independent
probes, instrumentation or liquid CO2
back-up system injection.
11. Vacuum release port.
1
8
9
7
The Panasonic ergonomic design
features a high-security Easy-In/
Easy-Out door latch designed for
simplicity and safety. The outer
door latch closes smoothly with
a single-hand action over a cam
action bearing. The outer door can
be secured with an independent
padlock provided by customer.
2
Inner Door Latches
provide single-hand
access.
5
11
10
6
Panasonic microprocessor-based controller
includes comprehensive set-point, alarm,
monitoring and diagnostic functions.
3
4
PRO Series -86ºC
Freezer Performance
Advantages
PRO Series -86ºC
Freezer Performance
Advantages
Panasonic Healthcare Company of North America
24
Ultra-Low and Cryogenic Freezers
Panasonic freezers emit less heat
into the laboratory, minimizing air
conditioning costs*.
12
10
8
6
4
2
0
Dollars / Cubic Foot
10.27
11.11
10.93
Total Annual Electrical Cost
per Box Capacity
Panasonic freezers help the environment
by reducing carbon footprint*.
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
Dollars ($)
0.82
0.89 0.88
Annual CO2 Emissions
by Box Capacity
Panasonic
MDF-U7486SC
Brand A
Brand B
*Based on internal performance data. Tested in 25°C ambient environment. Freezer cycling at -80°C.
Cabinet volume, 25 cu. ft. Average cabinet temperature based on temperature mapping (15 thermocouples).
Panasonic freezers provide reduced
operational cost for highly efcient
sample storage*.
Power Consumption by Capacity
(KW/day/box Efciency)
1.73
2.25 2.21
Watts
3.0
2.5
2.0
1.5
1.0
0.5
0.0
PRO Series Comparative
Energy Performance
PRO Series Comparative
Energy Performance
Description
Model Number MDF-U5486SC-PA MDF-U7486SC-PA
Refrigeration System, HFC Refrigerants, Cool Safe High Performance Compressors
High Stage 110 0 W 110 0 W
Low Stage 110 0 W 110 0 W
Voltage Booster, Built-In Standard Standard
Sound Abatement Standard (< 51dB(A)) Standard (< 51dB(A))
Construction
Shelf Stainless steel, adjustable 3 shelves
Access Port .066" (17 mm) diameter,
Refrigerants HFC refrigerants
Alarm High/low temp, Power failure, Filter check, Battery check
Remote Alarm Contact N.O. and N.C., allowable contact capacity: DC30V, 2A
Technical Specications Technical Specications
25
Ultra-Low and Cryogenic Freezers
Cryogenic Freezer
MDF-C2156VANC-PA
Temperature Uniformity
for Long-term Storage
What keeps our Cryogenic freezer so stable?
Temperature Uniformity
for Long-term Storage
What keeps our Cryogenic freezer so stable?
Panasonic Cryogenic freezer maintains uniform temperature of -150°C for stable, long-term preservation of
cells and tissue. Panasonic VIP® PLUS Cryogenic Series -150°C ultra-low temperature freezer achieves more
storage capacity than a conventionally insulated freezer without increasing footprint.
Comparison of temperature distribution in a liquid nitrogen freezer (vapor phase) and
Panasonic’s MDF-C2156VANC mechanically refrigerated cryogenic freezer. Graph shows
temperatures at different locations within the chamber. This data demonstrates that 100% of
the MDF-C2156VANC-PA storage space maintains uniform storage temperatures safely below
-130ºC, while temperature in LN2 vapor system is dependent on storage location.
Uniform Cryogenic Temperatures
±5ºC uniformity* in a mechanically refrigerated
design promotes better top-to-bottom uniformity
than liquid nitrogen vapor-phase storage, without
the concern of cross-contamination often associ-
ated with liquid nitrogen (liquid phase storage).
Panasonic Healthcare Company of North America
26
Liquid Nitrogen freezer ( Vapor Phase ) Panasonic MDF-C215VANC
mechanically refrigerated cyrogenic freezer
Based on internal validation data
tested at -150°C setpoint, in an empty
chamber with 23°C ambient temperature.
* The data may vary depending on the use, circumstances and optional accessories. Validation documents can be provided for each serial number with an additional fee.
Patented revolutionary vacuum insulation cabinet construction reduces wall
thickness and achieves more storage capacity than a conventionally insulated
freezer without increasing the footprint.
• The newly developed refrigeration system and the freezer structure offer
a quiet environment.
• Achieves 50% higher energy conservation than conventionally insulated model.
• The temperature inside the freezer can be set and monitored easily by means of
precise microprocessor temperature control with an LCD graphic display. The
controller utilizes a platinum RTD sensor which is extremely precise and durable.
• Status Alert monitors ambient and system conditions continuously and noties
of any abnormalities before a problem can occur. In case of power failure or an
irregular rise in temperature, a rechargeable, high capacity battery-operated
indicator lamp and alarm will be activated.
• Graphic LCD panel with pop-up menu function on control panel provides a precise
visual display and allows intuitive operation.
• VIP® PLUS offers superior performance in insulating properties providing
unsurpassed uniformity in the chamber- top to bottom, side to side, front to back.
• The MDF-C2156VANC is equipped with LN2 backup system as standard to prepare
for any contingency. The built-in LN2 back-up system is self activated if a power
outage occurs. This feature helps ensure that the contents will be protected in the
event of any power failure.
Product Features Product Features
Description
Model Number MDF-C2156VANC-PA
Temperature Range -125°C to -150°C (1°C increments)
Max Cooling Performance -150°C (ambient temp 30°C)
Uniformity ±7°C at -150°C (empty chamber, ambient temp 24°C)
Capacity 8.2 cu.ft.
231 liters
Exterior Dimensions (w x f-b x h) 68.1” x 30.1” x 39.8”
1730 x 765 x 1010 mm
Interior Dimensions (w x f-b x h) 29.9” x 19.5” x 24.2”
760 x 495 x 615 mm
Net Weight Approx.715lbs (325kg)
Access Port 40mm diameter, 1 location
Compressor Hermetic type, 1100W (high stage side)
1100W (low stage side)
Refrigerants HFC Free
Alarm High/Low temperature, power failure, lter check, self diagnosis, lid check
Remote Alarm Contact Allowable contact capacity DC 30V, 2A
Power Requirements 208V-230V, 1 phase, 60Hz NEMA 6-15R (15 Amp) Receptacle
Technical Specications Technical Specications
Graphic display
(LCD)
Warning indicator (Lit even
during power outage)
S e t t i n g
input
Buzzer silence:
Hold for alarm test
Warning
information
Status
display
Door display
Ultra-Low and Cryogenic Freezers
27
Chest Freezers
MDF-794C-PA
Space-Saving Stability
What makes Chest freezers
compact yet equally effective?
Space-Saving Stability
What makes Chest freezers
compact yet equally effective?
MDF-C8V1-PA
All ultra-low chest models use Panasonic-designed compressors for ultra-low temperature applications. Manufactured
with foamed-in-place insulation, they are ideally suited for use in hospitals and laboratories for long-term preservation and
storage of specimens and components, as well as materials testing.
Microprocessor Controls
Comprehensive set-point, alarm, monitoring and diagnostic
functions based on Panasonic-built microprocessor controller
with digital display of all input/output functions.
Panasonic-Designed Refrigeration and Compressors
Designed by Panasonic specically for rugged ultra-low
temperature applications in a laboratory environment; HCFC-free
refrigerants only.
High-performance refrigeration system with foam-in-place
cabinet insulation maximizes interior temperature uniformity and
protects against uctuating ambient temperatures.
High Density Blown-In Foam Insulation
and Heated Gasket Seal
In ultra-low temperature freezers, effective insulation is critical.
The insulation used in Panasonic ultra-low freezers is two
layers of rigid, foamed-in-place polyurethane, placed together
to form a double-insulation wall.
This design prevents the insulation layers from distortion and
cracking that might occur due to temperature differences inside
and out.
Frost and icing on the top edges and gaskets are prevented
by utilization of a heated mullion, which recycles heat from the
refrigeration system without affecting chamber uniformity.
Built-In Temperature & Power Failure Alarms
(Lamp/Buzzer)
In case of power failure or an irregular rise in temperature, a high
capacity, rechargeable battery-operated indicator lamp and alarm
will be activated.
Optional CO2 and LN2 back-up systems are available and are
self-activated when a power outage occurs. This equipment helps
ensure that the contents will be protected in the event of any power
failure or mechanical trouble.
Product Features Product Features
Panasonic Healthcare Company of North America
28
Description
Model Number MDF-C8V1-PA
Temperature Range -60°C to -80°C (-1°C increments)
Max Cooling Performance -80°C (Ambient Temp 30°C)
Effective Capacity 3.0 cu.ft. (85 liters)
Exterior Dimensions (w x f-b x h) 21.6” x 27.0” x 37.2” / 550 x 685 x 945 mm
Interior Dimensions (w x f-b x h) 15.9” x 19.3” x 16.9” / 405 x 490 x 425 mm
Net Weight Approx. 148lbs (67kg)
Storage Capacity 2" Box: 42 pcs. (SCR-072 x 6 racks) 3" Box: 30 pcs
Outer Door / Inner Door Outer Lid: 1 piece; Inner Lid: 1 piece
Insulation VIP® PLUS rigid polyurethane foam (HC)
Cooling System 115V / 60Hz / 1 Phase NEMA 5-15P Plug
Compressor Rotary Type
Refrigerant HFC
Evaporator Tube on Sheet Type
Alarm System High / Low Temp. Alarm (±5°C to ±20°C); Power Failure Alarm; Remote Alarm Contact: DC30C, 2A (N.O./N.C.)
Technical Specications Technical Specications
Description
Model Number MDF-594C-PA MDF-794C-PA
Temperature Range -20°C to -86°C
Cabinet Insulation Rigid polyurethane foamed-in place
Exterior Dimensions (w x f-b x h) 79.1” x 30.3” x 42.1” / 2010 x 770 x 1070 mm 101.2” x 30.3” x 42.1” / 2570 x 770 x 1070 mm
Interior Dimensions (w x f-b x h) 50.3” x 19.7” x 30” / 1280 x 500 x 762 mm 72.4” x 19.7” x 30” / 1840 x 500 x 762 mm
Effective Capacity 19.2 cu.ft. (487 Liters) 24.8 cu.ft. (701 Liters)
Exterior Cabinet Painted Steel
Interior Cabinet Stainless Steel
Inner Sub-Lid 34
Net Weight (approx.) 672lbs (303kg) 827lbs (347kg)
Compressor (high stage) Hermetic type 750W Hermetic type 1100W
Compressor (low stage) Hermetic type 750W Hermetic type 1100W
Evaporator (high stage) Cascade condenser
Evaporator (low stage) Tube on sheet (shared with interior)
Condenser (high stage) Fine and tube type
Condenser (low stage) Shell and tube type
Temperature Control Microprocessor: Keypad input; Temp. input range: -20°C to -86°C (1C increment); Set value memory: nonvolatile memory
Temperature Display Digital Display
Sensor Platinum Resistance (Pt. 100)
Alarm System Selectable high temp. alarm (+10°C & +15°C from set point), Power Failure alarm, Filter check lamp, Remote alarm contact
Power Requirement 208 / 220V / 60hz built-in voltage booster
Ultra-Low and Cryogenic Freezers
Thinking Green: Environmentally friendly refrigerants,
RoHS compliant and low-noise operation.
29
Your Panasonic experience with product safety, reliability and performance is
supported by a multi-national network of factory-trained service professionals
located in all markets we serve. The serviceability of Panasonic Healthcare products
is inherent to all Panasonic product designs and originates in our research and
development department. Combined with customer feedback and detailed
documentation of eld performance, Panasonic product developers incorporate
real-world applications into product systems and operating parameters.
From ambient temperature and humidity uctuations to broad electrical voltage
tolerances, Panasonic Healthcare products are expected to withstand demands in
the newest of facilities as well as older labs. Central to our product development
efforts is the concept of “predictive performance”, a matrix of electronics
and control functions that sense component operation in real time, compare
performance to accepted norms and report exceptions long before normal wear
and tear causes an interruption. As a result, many Panasonic Healthcare products
include self-diagnostics that permit authorized service technicians to determine how
and when service calls are required.
As Panasonic continues to apply improvements in compressor and electronics to
all products, life cycle costs can be extended and downtime minimized. Panasonic
service specialists are trained to perform remote and on-site diagnostics, repair
and replace worn components and offer preventative maintenance programs
suitable to your needs and budget. Panasonic Healthcare also offers training to
selected facility biomedical engineers and service staff for authorized in-warranty
and post-warranty repairs.
Because Panasonic Healthcare products are sold and serviced worldwide,
products acquired in one country under grant or facility-sharing programs are easily
supported if moved to facilities in the next city or around the world.
Product Service
and Uptime Assurance
Product Service
and Uptime Assurance
Validation Services
Panasonic offers a wide range of high-quality val-
idation services for all our equipment. These ser-
vices include on-site validation, custom validation
support packages, factory acceptance testing,
and NIST traceable calibration.
Choosing Panasonic as an equipment supplier
and validation consultant can greatly reduce the
time and cost involved with new equipment.
Unique Services Panasonic Offers:
On-site consultation
Specialized documentation for
each individual unit
Customized testing procedures
based on personalized customer requirements
No charge for documentation
when service is purchased
Quality documents complying with
21 CFR traceable standards
Free archiving of unexecuted
testing protocols
Pre-Delivery and On-Site Services
Pre-delivery services include factory
acceptance testing, calibration, and
temperature mapping. On-site services
include installation qualication, operational quali-
cation, performance qualication, calibration and
temperature mapping.
Panasonic Connect
Panasonic’s customer-driven service program
guarantees local attention from qualied Panason-
ic service representatives, whenever and wherever
you need it.
New Unit Installation and Training
Preventative Maintenance
Warranty and Non-Warranty Repairs
Calibration/Validation Services
Refurbishment and Reconditioning
Customized Service and Warranty Programs
Loaner Units When Needed
In-Stock Parts for Immediate Delivery
Prices and conditions may vary by market.
Panasonic Healthcare Company of North America
1300 Michael Drive, Suite A, Wood Dale, IL 60191
Toll Free USA (800) 858-8442, Fax (630) 238-0074
www.panasonic.com/biomedical
© Panasonic Printed in USA 2013.04 AG

Navigation menu