R3202 Product Catalogue FF 2013 EN Low Res

User Manual: R3202

Open the PDF directly: View PDF PDF.
Page Count: 84

DownloadR3202 Product-Catalogue-FF 2013 EN Low Res
Open PDF In BrowserView PDF
R-Biopharm AG

Product catalogue
Food & Feed Analysis

R-Biopharm – for the safety of your analysis.

2017

Product catalogue 2017
Food & Feed Analysis

R-Biopharm AG – Product catalogue 2017

Content
Overview of test systems by R-Biopharm
Enzymatic analysis
•
•
•
•
•
•

"Yellow Line" Roche Diagnostics
Enzytec™ Color
Enzytec™ Fluid
Enzytec™ Generic
Enzytec™ Liquid
RIDA®CUBE (only for RIDA®CUBE SCAN*)

Vitamin analysis

6
8
10
11
11
12
12
13

• VitaFast®
• EASI-EXTRACT®

14
16
17

• RIDASCREEN®

17

Mycotoxins

18
18
26
30
33

•
•
•
•

ELISA, lateral flow and immunoaffinity columns
Automated online analysis
Standards for mycotoxin analysis
Reference material for mycotoxin analysis

Residues
•
•
•
•

Hormones & anabolics
Antibiotics
Phycotoxins
Food adulteration

34
34
38
43
43

Histamine

43

Allergens

44
44

• ELISA, lateral flow and real-time PCR

4

GMO
•
•
•
•

DNA preparation
Screening
Real-time PCR – qualitative DNA detection
Real-time PCR – quantitative DNA detection

Identification of animal species/risk material/BSE
•
•
•
•
•

Real-time PCR – qualitative DNA detection
Real-time PCR – quantitative DNA detection
SureFood® FISH ID
Risk material
BSE

54
56
56
56
57
58
60
61
62
63
63

Microbiology/hygiene

64

• Culture medium systems for colony counting and pathogen detection
	 
in food or surface samples
• Culture medium systems for surface specimen/hygiene monitoring
• Pathogens & bacterial toxins
• Viruses
• Water analysis
• Beverage analysis
• Test Systems for cleaning control

66
67
68
70
70
71
73

Equipment/software/accessories
• Equipment
• Software
• Accessories

74
76
77
78

Explanation

79

The R-Biopharm Group – contact us

80

General Terms & Conditions of R-Biopharm AG

82

5

R-Biopharm AG – Product catalogue 2017

Overview of test systems
by R-Biopharm
ELISA – RIDASCREEN®
•
•
•
•

Quantitative results
Applications for many matrices
Analysis by RIDA®SOFT Win
Can be automated

LFD – RIDA®QUICK
• Immunochromatographic tests
• Applications for many matrices
• Visual evaluation
(qualitative and semi-quantitative)
• Qualitative evaluation (analysis by
RIDA®QUICK SCAN and RIDA®SMART APP)

Immunoaffinity columns – PREP®, EASI-EXTRACT®
• For sample preparation prior to analysis by HPLC,
LC-MS/MS or ELISA
• Single and multiparameter
• High specificity
• For simple and complex matrices

Enzymatic analytics – Roche, Enzytec™, RIDA®CUBE
• UV-tests (reference methods)
• Tests for automation
• Single-use cartridge system

6

Real-time PCR – SureFood®/SureFast®
•
•
•
•

Modular, open test systems
DNA/RNA preparation, screening, identification, quantification
Single and multiplex tests
Suitable for all established thermal cyclers

Quality assurance – Trilogy®
•
•
•
•

Standard materials for calibration (crystalline & liquid)
Reference materials (naturally contaminated matrices)
Materials for quality control
RIDA® spiking solutions for validation

Ready to use culture medium systems –
RIDA®STAMP, Compact Dry
• As proof of bacteria, yeasts and moulds
• For food samples and surface analysis
• Chromogenic proof systems for simple identification
and enumeration of colonies

Equipment/automation
• Small automates for on site single testing
• Automates for 1 - 2 microtiter plates
• Evaluation with RIDA®SOFT Win

7

R-Biopharm AG – Product catalogue 2017

Enzymatic analysis for food
and feed
Enzymatic tests are widely used as analytical tools for the analysis of
food products such as fruit juices, wine or beer, dairy products, eggs
and meat. Enzymatic test kits determine sugars, acids, alcohols and
a few other food components.
They are based on high quality enzymes,
enabling precise and specific measurements
of each compound, even in complex
matrices. Results are measured with a
spectrophotometer and automation is
possible. Numerous enzymatic methods
have been approved or validated by
international organisations.
The “Yellow line” kits are produced by
Roche (previously Boehringer Mannheim),
with more than 40 years of experience in
the production of the enzymes, which are
the key element of each test. The Roche
test kits have been used and validated
worldwide for several decades, with many
corresponding publications. They have
been selected as reference method by
many international organizations and
they are still the reference quality today.

8

As an alternative, R-Biopharm also offers
the Enzytec™ Generic line.
The Enzytec™ Color line is a new product
range for colorimetric assays. They are
based on a chemical reaction with a
chromogen in the visible range, without
using any enzyme.
Enzytec™ Fluid kits are produced by
Thermo Scientific, whereas
Enzytec™ Liquid kits are produced by
R-Biopharm. These reagents are all liquid
and ready-to-use, so they can be placed
directly on any biochemistry analyser and
stay on board for true random-access
capability.
The new product line RIDA®CUBE enables
single testing. The test cartridges are
ready-to-use and allow a rapid analysis.
The RIDA®CUBE kits can only be used in
combination with the RIDA®CUBE SCAN
instrument.

Roche "Yellow Line"
• Reference quality for more than 40 years
• 31 tests for all requirements in the
food industry
• Produced by Roche Diagnostics

Enzytec™ Fluid or Enzytec™ Liquid
• Liquid, ready-to-use reagents
• Stable until end of shelf-life,
even after opening
• Easy and safe use on biochemistry
analysers

RIDA®CUBE SCAN
• Small but precise like a big
biochemistry analyser
• Ready-to-use test cartridges for
single testing
• Only one pipeting step and the result
after 15 minutes.

9

R-Biopharm AG – Product catalogue 2017

Enzymatic food analysis
"Yellow Line" Roche Diagnostics
Product

Description

"Yellow Line" Roche Diagnostics

Acids

Acetic acid

Enzymatic test (340 nm)

3 x 11 determinations

10148261035

L-Ascorbic acid

Enzymatic test (578 nm)

21 determinations

10409677035

Citric acid

Enzymatic test (340 nm)

3 x 12 determinations

10139076035

Formic acid

Enzymatic test (340 nm)

21 determinations

10979732035

D-Gluconic acid

Enzymatic test (340 nm)

27 determinations

10428191035

L-Glutamic acid

Enzymatic test (492 nm)

3 x 13 determinations

10139092035

D-3-Hydroxybutyric acid

Enzymatic test (492 nm)

3 x 12 determinations

10907979035

D-Isocitric acid

Enzymatic test (340 nm)

33 determinations

10414433035

D-/L-Lactic acid

Enzymatic test (340 nm)

30 determinations of each

11112821035

L-Lactic acid

Enzymatic test (340 nm)

30 determinations

10139084035

D-Malic acid

Enzymatic test (340 nm)

3 x 11 determinations

11215558035

L-Malic acid

Enzymatic test (340 nm)

30 determinations

10139068035

Succinic acid

Enzymatic test (340 nm)

11 determinations

10176281035

"Yellow Line" Roche Diagnostics

Sugars

D-Glucose

Enzymatic test (340 nm)

3 x 45 determinations

10716251035

D-Glucose/D-Fructose

Enzymatic test (340 nm)

27 determinations of each

10139106035

Lactose/D-Galactose

Enzymatic test (340 nm)

32 determinations

10176303035

Lactose/D-Glucose

Enzymatic test (340 nm)

32 determinations of each

10986119035

Maltose/Sucrose/D-Glucose

Enzymatic test (340 nm)

15 determinations of each

11113950035

Raffinose

Enzymatic test (340 nm)

32 determinations

10428167035

Sucrose/D-Glucose

Enzymatic test (340 nm)

22 determinations of each

10139041035

Sucrose/D-Glucose/D-Fructose

Enzymatic test (340 nm)

22 determinations of each

10716260035

Starch

Enzymatic test (340 nm)

27 determinations

10207748035

"Yellow Line" Roche Diagnostics

Others

Acetaldehyde

Enzymatic test (340 nm)

3 x 11 determinations

10668613035

Ammonia

Enzymatic test (340 nm)

50 determinations

11112732035

Urea/Ammonia

Enzymatic test (340 nm)

25 determinations of each

10542946035

Cholesterol

Enzymatic test (405 nm)

31 determinations

10139050035

Ethanol

Enzymatic test (340 nm)

33 determinations

10176290035

Glycerol

Enzymatic test (340 nm)

3 x 11 determinations

10148270035

Nitrate

Enzymatic test (340 nm)

3 x 13 determinations

10905658035

D-Sorbitol/Xylitol

Enzymatic test (492 nm)

3 x 12 determinations

10670057035

Sulfite (SO2)

Enzymatic test (340 nm)

31 determinations

10725854035

"Yellow Line" Roche Diagnostics

Accessories

Cuvettes Holder

1

10019624035

Plastic Spatulas

500 pcs.

10019623035

10

No. of tests/amount Art. No.

Enzymatic food analysis
Enzytec™ Color
Product

Description

Enzytec™ Color

Test kits

No. of tests/amount Art. No.

Copper

Colorimeric test (580 nm)

2 x 50 ml

E2400

Iron

Colorimeric test (580 nm)

4 x 100 ml

E2300

GlucaTest®S125
GlucaTest®L500

Colorimeric test (550 nm)

125 ml (40 tests)
4 x 125 ml (160 tests)

E3500
E3550

Free sulfite

Colorimeric test (340 nm)

2 x 100 ml

E3300

Total sulfite

Colorimeric test (340 nm)

2 x 100 ml

E3200

Tartaric acid

Colorimeric test (520 nm)

2 x 80 ml

E3100

Enzytec™ Fluid
Enzytec™ Fluid

Acids

Acetic acid

Enzymatic test (340 nm)

For automation only

E5226

D-Lactic acid

Enzymatic test (340 nm)

4 x 10 determinations

E5240

L-Lactic acid

Enzymatic test (340 nm)

4 x 10 determinations

E5260

L-Malic acid

Enzymatic test (340 nm)

4 x 10 determinations

E5280

Enzytec™ Fluid

Sugars

D-Fructose

Enzymatic test (340 nm)

4 x 10 determinations

E5120

D-Glucose

Enzymatic test (340 nm)

4 x 10 determinations

E5140

Glucose/Fructose

Enzymatic test (340 nm)

4 x 10 determinations

E5160

Sucrose (via Glucose)

Enzymatic test (340 nm)

4 x 10 determinations

E5180

Enzytec™ Fluid

Others

Ammonia

Enzymatic test (340 nm)

4 x 10 determinations

E5390

Ethanol

Enzymatic test (340 nm)

4 x 10 determinations

E5340

Glycerol

Enzymatic test (340 nm)

4 x 10 determinations

E5360

Enzytec™ Fluid

Standards

Alcohol Standard

Alcohol assay control solution

10 x 1 ml

E5420

Sugar combination Standard

Multi-sugar assay control solution

3 x 3 ml

E5440

Sugar Standard for automation

Multi-sugar calibration solution for automation

3 x 3 ml

E5450

11

R-Biopharm AG – Product catalogue 2017

Enzymatic food analysis
Enzytec™ Generic
Product

Description

Enzytec™ Generic

Acids

No. of tests/amount Art. No.

Acetic acid

Enzymatic test (340 nm)

2 x 16 determinations

E1226

L-Ascorbic acid

Enzymatic test (578 nm)

3 x 8 determinations

E1267

Citric acid

Enzymatic test (340 nm)

24 determinations

E1214

D-Gluconic acid

Enzymatic test (340 nm)

32 determinations

E1223

D/L-Lactic acid

Enzymatic test (340 nm)

32 determinations

E1255

L-Lactic acid

Enzymatic test (340 nm)

32 determinations

E1254

L-Malic acid

Enzymatic test (340 nm)

32 determinations

E1215

Oxalic acid

Enzymatic test (590 nm)

10 determinations

E2100

Sample purifier

Sample preparation for Enzymatic tests

20 samples

E2250

Enzytec™ Generic

Sugars

D-Glucose

Enzymatic test (340 nm)

32 determinations

E1210

D-Glucose/D-Fructose

Enzymatic test (340 nm)

32 determinations of each

E1245

Lactose/D-Galactose

Enzymatic test (340 nm)

32 determinations

E1213

Starch

Enzymatic test (340 nm)

32 determinations

E1268

Sucrose/D-Glucose

Enzymatic test (340 nm)

16 determinations of each

E1246

Sucrose/D-Glucose/D-Fructose

Enzymatic test (340 nm)

16 determinations of each

E1247

Glucose remover

For removal of glucose excess in samples

32

E3400

Enzytec™ Generic

Standards

Multi-acid standard manual

Multi-acid assay control solution

9 ml

E1240

Multi-acid standard for automation

Multi-acid calibration solution for automation

9 ml

E1241

Sugar Standard manual

Multi-sugar assay control solution

9 ml

E1242

Enzytec™ Liquid
Enzytec™ Liquid

Acids

Acetic acid

Enzymatic test (340 nm)

For automation only

E8226

D-/L-Lactic acid

Enzymatic test (340 nm)

2 x 25 determinations

E8240

Lactic acid

Enzymatic test (340 nm)

2 x 25 determinations

E8260

Malic acid

Enzymatic test (340 nm)

2 x 25 determinations

E8280

Enzytec™ Liquid

Sugars

D-Glucose

Enzymatic test (340 nm)

2 x 25 determinations

E8140

D-Glucose/D-Fructose

Enzymatic test (340 nm)

2 x 25 determinations

E8160

Sucrose/D-Glucose

Enzymatic test (340 nm)

2 x 25 determinations

E8180

Sucrose/D-Glucose/D-Fructose

Enzymatic test (340 nm)

2 x 25 determinations

E8190

Enzytec™ Liquid

Others

Ethanol

Enzymatic test (340 nm)

2 x 25 determinations

E8340

12

Enzymatic food analysis
RIDA®CUBE (only for RIDA®CUBE SCAN*)
Product

Description

RIDA®CUBE

Ready to use cartridges

No. of tests/amount Art. No.

Acetic acid

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4226

Ethanol

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4340

Glucose

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4140

D-Glucose/D-Fructose

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4160

DL-Lactic (without differenciation)

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4240

L-Lactic acid

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4260

L-Malic acid

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4280

SO2-Free (Free Sulfite)

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4610

SO2-Total (Total Sulfite)

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4600

Sucrose/D-Glucose

Enzymatic test only with RIDA®CUBE SCAN (340 nm)

32 determinations

RCS4180

* See page 76 – • Equipment/software/accessories.

13

R-Biopharm AG – Product catalogue 2017

Vitamin analysis in food,
feed and vitamin containing
products
Food products are now being enriched and fortified with vitamins in
many forms. But does the amount present in the food at the end of
the shelf life match the label on the package?
Food manufacturers, regulatory agencies
and commercial laboratories should
therefore have analytical methods on
hand that allow them to quickly and
reliably determine the natural and added
vitamin content of food products.
Product testing:
There are different methods for analysing
water soluble vitamins: ELISA, immunoaffinity columns (IAC), microbiological
and enzymatic microtiter plate tests. The
new developed RIDASCREEN®FAST
Vitamin B12 and Folic Acid tests allow a
quantitative determination of both
vitamins within 1 h. The total vitamin B12
content is determined without using
cyanide. Regarding folic acid and biotin
the added vitamin content is determined.

14

When using Immunoaffinity columns in
conjunction with HPLC or LC-MS/MS,
the sample is purified and the vitamin is
retained by the antibody in the column.
Using the EASI-EXTRACT® VITAMIN B12
and BIOTIN (IAC), you can determine the
total vitamin content. With the
EASI-EXTRACT® FOLIC ACID (IAC) you can
only determine added folic acid.
Depending on the sample preparation the
added or total vitamin content can be
determined with the microbiological
VitaFast® test. With the enzymatic
VitaFast® Vitamin C test in microtiter plate
format a determination of total vitamin C
content (L-ascorbic acid and
L-dehydroascorbic acid) is possible.

VitaFast®
Microbiological test
• Samples with an added or natural
vitamin content can be analysed
• Method in conformity with official
guidelines (Section 64 of the
German Food & Feed Act, AOAC)
• AOAC-RI certification for some
VitaFast® tests
• Ready-to-use reagents and standards
for 96 determinations
• Results available within 24 - 48 hours

EASI-EXTRACT®
Immunoaffinity columns
• Isolation and concentration of
the vitamin
• Pigments and interfering compounds
are removed
• High recovery and low CV‘s
• Single peaks

RIDASCREEN®
ELISA
• Determination of total vitamin B12
content
• Determination of added vitamin
(folic acid , biotin)
• One sample preparation procedure
and one identical sample buffer for
RIDASCREEN®FAST B12 and Folic Acid
• Results within 1 hour
• Ideal for process control

15

R-Biopharm AG – Product catalogue 2017

Vitamins
VitaFast®
Product

Description

No. of tests/amount Art. No.

Microbiological microtiter plates
VitaFast® Folsäure/Folic Acid
AOAC-RI 100903

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.018 µg/100 g(ml)

96 determinations

P1001

VitaFast® Vitamin B12
(Cyanocobalamin)
AOAC-RI 101002

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.021 µg/100 g(ml)

96 determinations

P1002

VitaFast® Vitamin B7 (Biotin)
AOAC-RI 101001

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.013 µg/100 g(ml)

96 determinations

P1003

VitaFast® Vitamin B3 Niacin

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.0048 mg/100 g(ml)

96 determinations

P1004

VitaFast®
Pantothensäure/Pantothenic Acid
AOAC-RI 100904

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.0035 mg/100 g(ml)

96 determinations

P1005

VitaFast® Vitamin B1 (Thiamin)

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.008 mg/100 g(ml)

96 determinations

P1006

VitaFast® Vitamin B2 (Riboflavin)
AOAC-RI 100902

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.0018 mg/100 g(ml)

96 determinations

P1007

VitaFast® Vitamin B6 (Pyridoxin)

Quantitative determination of the total vitamin content
(added and natural) or of the added vitamin only
Limit of detection: 0.0002 mg/100 g(ml)

96 determinations

P1008

VitaFast® Inositol

Quantitative determination of the total vitamin content
(added and natural)
Limit of detection: 0.5 mg/100 g(ml)

96 determinations

P1009

50 determinations

P1010

Enzymatic microtiter plate
VitaFast® Vitamin C
(L-Ascorbic Acid)

Quantitative determination of vitamin C
(L-ascorbic acid and L-dehydroascorbic acid) possible
Limit of detection: 7.8 mg/100 g(ml)
Spiking standards

VitaFast® Folsäure/Folic Acid
Spiking standard

Folic Acid in solid form

3 vials

P3001

VitaFast® Vitamin B12
(Cyanocobalamin)
Spiking standard

Cyanocobalamin in solid form

3 vials

P3002

VitaFast® Vitamin B7 (Biotin)
Spiking standard

D-Biotin in solid form

3 vials

P3003

VitaFast®
Pantothensäure/Pantothenic Acid
Spiking standard

Ca-D-Pantothenat in solid form

3 vials

P3005

1 vial for
50 sample preparations

P2002

Enzyme
VitaFast® Chicken Pancreatin

16

Enzyme for sample preparation for determination of
natural folic acid

Vitamins
EASI-EXTRACT®
Product

Description

No. of tests/amount Art. No.

Immunoaffinity columns
EASI-EXTRACT® VITAMIN B12

Immunoaffinity columns for sample clean-up prior to the
analysis of vitamin B12 using HPLC or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP80
RBRP80B

EASI-EXTRACT® VITAMIN B12 (LGE)
AOAC „First Action“ certified

Immunoaffinity columns for sample clean-up prior to the
analysis of vitamin B12 using HPLC or LC-MS/MS

10 columns (10 ml format)
50 columns (10 ml format)

RBRP88
RBRP88B

EASI-EXTRACT® FOLIC ACID

Immunoaffinity columns for sample clean-up prior to the
analysis of folic acid using HPLC or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP81
RBRP81B

EASI-EXTRACT® BIOTIN

Immunoaffinity columns for sample clean-up prior to the
analysis of biotin using HPLC or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP82
RBRP82B

EASI-EXTRACT® MULTI-VIT B (LGE)

Immunoaffinity columns for sample clean-up prior to the
analysis of biotin, vitamin B12 and folic acid using HPLC

10 columns (10 ml format)
50 columns (10 ml format)

RBRP183
RBRP183B

RIDASCREEN®
ELISA microtiter plates
RIDASCREEN®FAST Vitamin B12

Enzyme immunoassay for quantitative analysis of total
vitamin B12 in fortified food and vitamin products
Limit of detection: 0.5 µg/kg

48 determinations
Incubation time: 25 min

R2103

RIDASCREEN® Biotin

Enzyme binding assay for quantitative analysis of biotin in
fortified food and vitamin products
Detection limit: 0.37 - 5.5 µg/kg depending on matrix

96 determinations
Incubation time: 1 hr 30 min

R2201

RIDASCREEN®FAST Folsäure
(Folic Acid)

Enzyme immunoassay for quantitative analysis of added
folic acid in fortified food and vitamin products
Limit of detection: 0.5 µg/kg

48 determinations
Incubation time: 25 min

R3203

17

R-Biopharm AG – Product catalogue 2017

Mycotoxin analysis in
food and feed
Mycotoxins are toxic secondary metabolites produced by fungi
(moulds). Mycotoxins can be formed in agricultural products, such
as cereals, and can also occur in related food, meat and dairy
products originating from farm animals.
Due to the frequent occurrence of
mycotoxins and their severe toxic effects
on animals and humans, maximum levels
(MLs) for the major mycotoxins have been
set by legislative bodies. In accordance
with these guidelines specific sample
preparation and detection methods were
developed. These include enzyme
immunoassays, lateral flow devices or
Immunoaffinity columns, etc.
R-Biopharm assays for screening of
mycotoxins in food and feed
• RIDASCREEN® enzyme immunoassays
(ELISAs) use the high specificity of
antigen and antibody interaction to
determine and quantify mycotoxins by
photometric measurement.
• RIDA®QUICK lateral flow tests are
immunochromatographic tests for
the determination of mycotoxins,
semi-quantitative (visual evaluation)
or quantitative (evaluation with
RIDA®QUICK SCAN reader or
RIDA®SMART APP software).

18

• Test cards, AFLACARD und OCHRACARD,
allow a qualitative screening of
mycotoxins at various levels in food and
feed commodities.
• Immunoaffinity columns
(RIDA®, EASI-EXTRACT®, PREP®) use the
high specificity of antigen and antibody
interaction to isolate, purify and
concentrate mycotoxins from many
complex matrices prior to ELISA or
chromatographic analysis.
• Clean-up columns are Solid phase
columns for the purification of
mycotoxin contaminated samples prior
to chromatographic analysis.

RIDA®QUICK
Lateral flow assay
• Semi-quantitative or
quantitative analysis
• Fast and reliable
New: Smartphone-based evaluation of all
quantitative tests with RIDA®SMART APP

RIDASCREEN®
ELISA tests for up to 96 determinations
• Highly sensitive
• Specific

RIDASCREEN®FAST
ELISA for up to 48/96 determinations
• Specific
• Fast and reliable

PREP®, EASI-EXTRACT®, RIDA®
Immunoaffinity columns
• Single or multi-toxin analysis in
conjunction with HPLC, LC-MS/MS
or ELISA
• For a wide range of matrices

Clean-up columns
Solid phase columns
• Rapid purification prior to
HPLC, GC or LC-MS/MS

19

R-Biopharm AG – Product catalogue 2017

Mycotoxins
Aflatoxins
Product

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN® Aflatoxin M1

Enzyme immunoassay for quantitative determination of
aflatoxin M1 in milk and milk powder*
Detection limit: 5 ng/kg (milk/reconst. milk powder),
50 ng/kg (milk powder)

96 determinations
Incubation time: 1 hr 15 min

R1121

RIDASCREEN®FAST Aflatoxin M1

Enzyme immunoassay for quantitative determination of
aflatoxin M1 in milk and milk powder
Detection limit: < 125 ng/kg

48 determinations
Incubation time: 15 min

R5812

RIDASCREEN® Aflatoxin B1 30/15

Enzyme immunoassay for quantitative determination of
aflatoxin B1 in cereals and feed
Detection limit: 1 µg/kg (cereals), 1.7 µg/kg (soy),
2 µg/kg (dry cat food), 4 µg/kg (feed)

96 determinations
Incubation time: 45 min

R1211

RIDASCREEN® Aflatoxin Total

Enzyme immunoassay for quantitative determination of total
aflatoxin in cereals and feed*
Detection limit: 1.75 µg/kg

96 determinations
Incubation time: 45 min

R4701

RIDASCREEN®FAST Aflatoxin

Enzyme immunoassay for quantitative determination of
aflatoxins in cereals and feed*
Detection limit: 1.7 µg/kg

48 determinations
Incubation time: 15 min

R5202

RIDASCREEN®FAST Aflatoxin SC
GIPSA/FGIS 2016-085

Enzyme immunoassay for quantitative determination of
aflatoxins in cereals and feed
Detection limit: 2 µg/kg

48 determinations
Incubation time: 15 min

R9002

Immunoaffinity columns
AFLAPREP®

Immunoaffinity columns for sample clean-up prior
to the analysis of aflatoxins B1, B2, G1 and G2 using HPLC
or LC-MS/MS

50 columns (1 ml format)

RBRP07

AFLAPREP® M

Immunoaffinity columns for sample clean-up prior to the
analysis of aflatoxin M1 using HPLC or LC-MS/MS

25 columns (1 ml format)

RBRP04

AFLAPREP® M WIDE

Immunoaffinity columns for sample clean-up prior to the
analysis of aflatoxin M1 using HPLC or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP124
RBRP124B

EASI-EXTRACT® AFLATOXIN

Immunoaffinity columns for sample clean-up prior to the
analysis of aflatoxins B1, B2, G1 and G2 using HPLC
or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRRP71
RBRRP70N

RIDA® Aflatoxin column

Immunoaffinity columns for sample clean-up prior to ELISA

10 columns (1 ml format)
50 columns (1 ml format)

R5001
R5002

50 columns (syringe format)

RBRP25

Solid phase column
PuriTox Aflatoxin

* Further applications on request.

20

Solid phase column for sample clean-up prior to the analysis
of total aflatoxins using HPLC or LC-MS/MS

Mycotoxins
Aflatoxins
Product

Description

No. of tests/amount Art. No.

Test strips
RIDA®QUICK Aflatoxin

Immunochromatographic test for the semi-quantitative
determination (visual evaluation) of aflatoxin in cereals, soy
flour, nuts, pistachios, coconut flour, sunflower seeds, figs,
dates and cashew nuts
Detection limit: 4, 10, 20 µg/kg

20 strips
Incubation time: 4 - 16 min

R5204

RIDA®QUICK Aflatoxin RQS
FGIS/GIPSA 2013-048

Immunochromatographic test for the quantitative
determination of aflatoxin in corn* in combination with
RIDA®QUICK SCAN reader or RIDA®SMART APP software
(page 77, Equipment/Accessories)
Detection limit: 4 µg/kg

20 strips
Incubation time: 5 min

R5205

RIDA®QUICK Aflatoxin RQS ECO

Immunochromatographic test with aqueous extraction for
the quantitative determination of aflatoxin in corn in combination with RIDA®QUICK SCAN reader or RIDA®SMART APP
software (page 77, Equipment/Accessories)
Detection limit: 4 µg/kg

20 stripes
Incubation time: 5 min

R5206

Test cards
AFLACARD B1

Qualitative detection of aflatoxin B1 at various
screening levels

20 determinations

RBRP27

AFLACARD TOTAL

Qualitative detection of total aflatoxins at various
screening levels

20 determinations

RBRP38

Ochratoxin A
ELISA microtiter plates
RIDASCREEN® Ochratoxin A 30/15

Enzyme immunoassay for quantitative determination of
ochratoxin A in cereals, feed, beer and pig serum*
Detection limit: 1.25 μg/kg (cereals/feed),
approx. 50 ng/kg (beer/pig serum)

96 determinations
Incubation time: 45 min

R1311

RIDASCREEN®FAST Ochratoxin A

Enzyme immunoassay for quantitative determination of
ochratoxin A in cereals and feed*
Detection limit: 5 µg/kg

48 determinations
Incubation time: 15 min

R5402

Immunoaffinity columns
OCHRAPREP®

Immunoaffinity columns for sample clean-up prior to the
analysis of ochratoxin A using HPLC or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP14
RBRP14B

RIDA® Ochratoxin A column

Immunoaffinity columns for sample clean-up prior to ELISA

10 columns (1ml format)

R1303

50 columns (syringe format)

RBRP13

20 determinations +
20 Immunoaffinity columns

RBRP48

Solid phase column
OCHRATOXIN
CLEAN-UP COLUMNS

Solid phase column for sample clean-up of specific matrices
in conjunction with OCHRACARD
Test cards

OCHRACARD

Qualitative detection of ochratoxin A at various
screening levels

* Further applications on request.

21

R-Biopharm AG – Product catalogue 2017

Mycotoxins
Zearalenone
Product

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN® Zearalenon

Enzyme immunoassay for quantitative determination of
zearalenone in cereals, feed, beer, serum and urine*
Detection limits: 50 ng/l (serum/urine), 250 ng/l (beer),
1750 ng/kg (cereals/feed)

96 determinations
Incubation time: 2 hrs 30 min

R1401

RIDASCREEN®FAST Zearalenon

Enzyme immunoassay for quantitative determination of
zearalenone in cereals and feed*
Detection limit: 17 - 41 µg/kg

48 determinations
Incubation time: 15 min

R5502

RIDASCREEN®FAST Zearalenon SC

Enzyme immunoassay for quantitative determination of
zearalenone in cereals
Detection limit: 5 µg/kg

48 determinations
Incubation time: 15 min

R5505

10 columns (3 ml format)
50 columns (3 ml format)

RBRRP91
RBRRP90

20 strips
Incubation time: 5 min

R5504

Immunoaffinity columns
EASI-EXTRACT® ZEARALENONE

Immunoaffinity columns for sample clean-up prior
to the analysis of zearalenone using HPLC or LC-MS/MS
Test strips

RIDA®QUICK Zearalenon RQS

Immunochromatographic test for the quantitative
determination of zearalenone in corn in combination with
RIDA®QUICK SCAN reader or RIDA®SMART APP software
(page 77, Equipment/ Accessories)
Detection limit: 75µg/kg (RIDA®QUICK SCAN),
50 µg/kg (RIDA®SMART APP)

DON (Vomitoxin)
ELISA microtiter plates
RIDASCREEN® DON

Enzyme immunoassay for quantitative determination of
deoxynivalenol in cereals, malt, feed, beer and wort
Detection limits: 18.5 µg/kg (cereals/malt/feed) and
3.7 µg/kg (beer/wort)

96 determinations
Incubation time: 45 min

R5906

RIDASCREEN®FAST DON
AOAC RI 000701 &
GIPSA/FGIS 2002-105

Enzyme immunoassay for quantitative determination of
DON in cereals, malt and feed
Detection limit: < 0.2 mg/kg

96 determinations
48 determinations
Incubation time: 8 min

R5901
R5902

RIDASCREEN®FAST DON SC
GIPSA/FGIS 2014-052

Enzyme immunoassay for quantitative determination of
DON in cereals, malt and feed
Detection limit: 0.074 mg/kg

48 determinations
Incubation time: 8 min

R5905

10 columns (3 ml format)
50 columns (3 ml format)

RBRP50
RBRP50B

20 strips
Incubation time: 5 min

R5904

Immunoaffinity columns
DONPREP®

Immunoaffinity columns for sample clean-up prior
to the analysis of deoxynivalenol using HPLC or LC-MS/MS
Test strips

RIDA®QUICK DON

22

Immunochromatographic test for the determination of DON
in grain: semi-quantitative (visual evaluation) or quantitative
(evaluation with RIDA®QUICK SCAN reader or
RIDA®SMART APP software, page 77, Equipment/Accessories)
Detection limit: 0.5 mg/kg

Mycotoxins
Fumonisins
Product

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN® Fumonisin

Enzyme immunoassay for quantitative analysis of fumonisins
in corn and corn products
Detection limit: 25 µg/kg

96 determinations
Incubation time: 45 min

R3401

RIDASCREEN®FAST Fumonisin
GIPSA/FGIS 2016-081

Enzyme immunoassay for quantitative determination of
fumonisins in cereals and feed
Detection limit: 0.222 mg/kg

48 determinations
Incubation time: 15 min

R5602

25 columns (3 ml format)

RBRP31

20 strips
Incubation time: 5 min

R5606

Immunoaffinity columns
FUMONIPREP®

Immunoaffinity columns for sample clean-up prior to the
analysis of fumonisins B1, B2 and B3 using HPLC or LC-MS/MS
Test strips

RIDA®QUICK Fumonisin RQS

Immunochromatographic test for the quantitative
determination of fumonisin in corn in combination with
RIDA®QUICK SCAN reader or RIDA®SMART APP software
(page 77, Equipment/ Accessories)
Detection limit: 0.3 mg/kg

T-2 Toxin
ELISA microtiter plates
RIDASCREEN® T-2 Toxin

Enzyme immunoassay for quantitative determination of
T-2 toxin in cereals and feed
Detection limit: < 5 µg/kg

96 determinations
Incubation time: 1 hr 30 min

R3801

RIDASCREEN®FAST T-2 Toxin

Enzyme immunoassay for quantitative determination of
T-2 toxin in cereals and feed
Detection limit: < 20 µg/kg

48 determinations
Incubation time: 15 min

R5302

96 determinations
Incubation time: 45 min

R3805

10 columns (3 ml format)
50 columns (3 ml format)

RBRP43
RBRP43B

20 strips
Incubation time: 5 min

R5304

T-2 / HT-2 Toxin
ELISA microtiter plates
RIDASCREEN® T-2 / HT-2 Toxin

Enzyme immunoassay for quantitative determination of
T-2/HT-2 toxin in oats, corn, barley and wheat
Detection limit: 16 μg/kg (oats), 12 μg/kg (corn),
21 μg/kg (wheat), 33 μg/kg (barley)
Immunoaffinity columns

EASI-EXTRACT® T-2 & HT-2

Immunoaffinity columns for sample clean-up prior
to the analysis of T-2 and HT-2 using HPLC or LC-MS/MS
Test strips

RIDA®QUICK T-2 / HT-2 RQS

Immunochromatographic test for or quantitative
determination of T-2/HT-2 toxin in oats, corn, and wheat in
combination with RIDA®QUICK SCAN reader or
RIDA®SMART APP software (page 77, Equipment/ Accessories)
Detection limit: 50 µg/kg

23

R-Biopharm AG – Product catalogue 2017

Mycotoxins
Citrinin
Product

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN®FAST Citrinin

Enzyme immunoassay for quantitative determination of
citrinin in cereals and feed
Detection limit: 15 µg/kg

48 determinations
Incubation time: 25 min

R6302

25 columns (3 ml format)

RBRP126

Immunoaffinity columns
EASI-EXTRACT® CITRININ

Immunoaffinity columns for sample clean-up prior to the
analysis of citrinin using HPLC or LC-MS/MS

Multi Toxin
Immunoaffinity columns
DZT MS-PREP®

Immunoaffinity columns for sample clean-up prior to the
analysis of deoxynivalenol, zearalenone, T-2 and HT-2 using
LC-MS/MS

10 columns (1 ml format)
50 columns (1 ml format)

RBRP73
RBRP73B

AFLAOCHRA PREP®

Immunoaffinity columns for sample clean-up prior to the
analysis of total aflatoxins and ochratoxin A using HPLC or
LC-MS/MS

10 columns (1 ml format)
50 columns (1 ml format)

RBRP89
RBRP89B

AOF MS-PREP®

Immunoaffinity columns for sample clean-up prior to the
analysis of total aflatoxins, ochratoxin A and fumonisin using
LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP115
RBRP115B

AO ZON PREP®

Immunoaffinity columns for sample clean-up prior
to the analysis of total aflatoxins, ochratoxin A and
zearalenone using HPLC or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP112
RBRP112B

Solid phase columns
PuriTox AflaZON

Solid phase column for sample clean-up prior to the analysis
of total aflatoxins and zearalenone using HPLC or LC-MS/MS

25 columns
(syringe format)

TC-M160

PuriTox Total Myco-MS

Solid phase column for sample clean-up prior to the analysis
of total aflatoxins, ochratoxin A, DON, 3-acetyl DON,
15-acetyl DON, ZON, T-2, HT-2, FB1, FB2 and FB3
using LC-MS/MS

25 columns
(syringe format)

TC-MT3000

Trichothecene
Solid phase columns
Trichothecene P columns

Solid phase column for sample clean-up prior to the analysis
of trichothecenes using GC or LC-MS/MS

30 columns
(test tube format)

RBRP51

PuriTox Trichothecene

Solid phase column for clean-up prior to the analysis of
trichothecenes using GC or LC-MS/MS

25 columns
(syringe format)

TC-T220

PuriTox DON/NIV

Solid phase column for clean-up prior to the analysis of
deoxynivalenol and nivalenol using GC or LC-MS/MS

25 columns
(gravity flow format)

TC-C210

24

Patulin
Product

Description

No. of tests/amount Art. No.

Enzyme
Pectinase

An enzyme for the clarification of cloudy apple juice
and apple purée prior to patulin analysis

100 determinations

RBRP129

10 columns (3 ml format)
50 columns (3 ml format)

RBRP250
RBRP250B

10 columns (3 ml format)
50 columns (3 ml format)

RBRP125
RBRP125B

Molecularly imprinted columns
EASIMIP™ PATULIN

Molecularly imprinted columns for sample clean-up prior to
the analysis of patulin using HPLC

Sterigmatocystin
Immunoaffinity columns
EASI-EXTRACT® STERIGMATOCYSTIN

Immunoaffinity columns for sample clean-up prior to the
analysis of sterigmatocystin using HPLC

25

R-Biopharm AG – Product catalogue 2017

Automated online analysis of
mycotoxins in food and feed
IMMUNOPREP® ONLINE immunoaffinity cartridges are used together
with the RIDA®CREST or RIDA®CREST ICE handling system to
combine automated online sample preparation with quantitative
analysis of the mycotoxin of interest.
The immunoaffinity cartridge contains a
monoclonal antibody that is specific for the
mycotoxin, coupled to a hydrophilic
polymer that can withstand high pressure.
The RIDA®CREST or RIDA®CREST ICE system
enables the use of the IMMUNOPREP
ONLINE cartridges to be incorporated
directly with HPLC, UHPLC or LC-MS/MS
systems.
The IMMUNOPREP® ONLINE cartridge
offers highly specific, sensitive, rapid and
automated analysis. The sample
application, washing and elution is
performed online for up to 12 samples
before the cartridge is automatically
removed and replaced with a new one.
This level of reuse has been found to offer
optimum cartridge performance and
removes the chance of interference or
carryover.
Following extraction of the toxin from the
sample with solvent, the extract is filtered,
diluted and transferred to an autosampler
vial. The diluted extract is injected onto the
immunoaffinity cartridge and any toxin
present in the sample is retained by
antibody in the cartridge. Unbound matrix
material is then automatically removed by
washing the cartridge and the resulting

26

wash goes to waste. Subsequently the
toxins are released from the antibody
following online elution with the mobile
phase and the complete elution fraction
from the cartridge is quantitatively analysed
for the mycotoxin of interest.

IMMUNOPREP® ONLINE
•
•
•
•
•
•

Improved Quality Assurance
Improved Traceability and Efficiency
Reusable cartridges
Increased sample throughput
Potential cost savings
New platform technology:
RIDA®CREST or RIDA®CREST ICE

Mycotoxins
Automated online analysis
Product

Description

Aflatoxin

Online immunoaffinity cartridges

No. of tests/amount Art. No.

IMMUNOPREP® ONLINE
AFLATOXIN

Online immunoaffinity cartridges used in conjunction with
the RIDA®CREST handling system for the automated
clean-up and analysis of aflatoxins B1, B2, G1 and G2 with
HPLC

48 cartridges
96 cartridges

RBRP900/48
RBRP900

IMMUNOPREP® ONLINE
AFLATOXIN M1

Online immunoaffinity cartridges used in conjunction with
the RIDA®CREST handling system for the automated
clean-up and analysis of aflatoxins M1 with HPLC

48 cartridges
96 cartridges

RBRP904/48
RBRP904

Ochratoxin A

Online immunoaffinity cartridges

IMMUNOPREP® ONLINE
OCHRATOXIN

Online immunoaffinity cartridges used in conjunction with
the RIDA®CREST handling system for the automated clean-up
and analysis of ochratoxin A with HPLC

48 cartridges
96 cartridges

RBRP901/48
RBRP901

DON (Vomitoxin)

Online immunoaffinity cartridges

IMMUNOPREP® ONLINE
DEOXYNIVALENOL

Online immunoaffinity cartridges used in conjunction with
the RIDA®CREST handling system for the automated clean-up
and analysis of deoxynivalenol with HPLC

48 cartridges
96 cartridges

RBRP902/48
RBRP902

27

R-Biopharm AG – Product catalogue 2017

Trilogy® certified mycotoxin
reference materials and
mycotoxin standards
Trilogy® Analytical Laboratory offers certified reference materials for
the quality assurance of mycotoxin analysis. Trilogy® certified
mycotoxin reference materials are naturally contaminated
homogeneous products that have been certified to contain a specific
concentration of one or more mycotoxins.
These reference materials have various

form. The Trilogy® standards can be used

applications including daily quality
assurance, technician training,
troubleshooting, proficiency testing, quality
documentation and method validation.
Reference materials are available containing
the major mycotoxins in various matrices
and levels of contamination:
Aflatoxin, Ochratoxin, Zearalenone,
Deoxynivalenol and Fumonisin
contaminated material are available, as well
as multi-toxin containing reference
materials. Commodities include corn and
corn by-products, wheat and wheat
products, barley and malted barley, oats,
rice and coffee as well as complex products
like animal feed. Samples are available in
100 g, 500 g and 1 kg re-sealable foil packs.

for spiking experiments in order to check
laboratory performance or for the analysis
of mycotoxins by HPLC, GC or LC-MS/MS.
The Trilogy® dried standards are very easy
to use. A simple reconstitution step reduces
the need to handle hazardous mycotoxin
powders.

Trilogy® also provides a wide range of
analytical standards for over 30 different
mycotoxins, both in solvents and in dry

28

The Trilogy® liquid standards are ready to
use and contain mycotoxins in dissolved
specified organic solvents. They are both
intended for use by customers who do not
have a spectrophotometer or for those who
want to ensure accurate HPLC/LC-MS/MS
determination of mycotoxins with minimal
preparation and effort. Shelf life for both
types of mycotoxin standards is typically
12 months after production; in addition to
that the Trilogy® dried standards have a
6 months shelf life after reconstitution.

Trilogy® certified
Mycotoxin reference material
• Naturally contaminated materials
• Single and multi-toxins
• Cereal, complex materials such as feed

Trilogy® mycotoxin standard
substances
• Dried standard substances
• Ready-to-use standards
• Single toxin and toxin groups

29

R-Biopharm AG – Product catalogue 2017

Mycotoxins
Mycotoxin standards
Product

Description

Aflatoxins

dried

No. of tests/amount Art. No.

Trilogy® Dried Standard
Aflatoxins B1, B2, G1, G2

Aflatoxins B1, B2, G1, G2 (4:1:4:1)
(2/0.5/2/0.5 µg/ml)

5 µg/ml
after reconstitution

TS-108

Trilogy® Dried Standard
Aflatoxin B1

Aflatoxin B-1

25 µg/ml
after reconstitution

TS-104

Trilogy® Dried Standard
Aflatoxin B2

Aflatoxin B-2

25 µg/ml
after reconstitution

TS-105

Trilogy® Dried Standard
Aflatoxin G1

Aflatoxin G-1

25 µg/ml
after reconstitution

TS-106

Trilogy® Dried Standard
Aflatoxin G2

Aflatoxin G-2

25 µg/ml
after reconstitution

TS-107

Trilogy® Dried Standard
Aflatoxin M1

Aflatoxin M1

1 µg/ml
after reconstitution

TS-130

liquid
Trilogy® Liquid Standard
Aflatoxin B1, B2, G1, G2

Aflatoxin B1, B2, G1, G2 (4:1:4:1),
5 µg/ml (2/0.5/2/0.5 µg/ml) in acetonitril

10 ml

TSL-108

AFLASTANDARD

Total aflatoxin standard (B1, B2, G1, G2) solution at
1000 ng/ml (250 ng/ml each) in methanol

6 ml
3 ml

RBRP22
RBRP22A

Trilogy® Liquid Standard
Aflatoxin B1

Aflatoxin B1;
25 µg/ml in acetonitrile

10 ml

TSL-104

Trilogy® Liquid Standard
Aflatoxin B2

Aflatoxin B2;
25 µg/ml in acetonitrile

10 ml

TSL-105

Trilogy® Liquid Standard
Aflatoxin G1

Aflatoxin G1;
25 µg/ml in acetonitrile

10 ml

TSL-106

Trilogy® Liquid Standard
Aflatoxin G2

Aflatoxin G2;
25 µg/ml in acetonitrile

10 ml

TSL-107

Trilogy® Liquid Standard
Aflatoxin M1

Aflatoxin M1;
0.5 µg/ml in acetonitrile

2 ml

TSL-143

M1 STANDARD

Aflatoxin M1 standard solution at a concentration
of 1000 ng/ml in acetonitrile

6 ml

RBRP42

Ochratoxin A

dried

Trilogy® Dried Standard
Ochratoxin A

Ochratoxin A

1 µg/ml
after reconstitution

TS-503

liquid
Trilogy® Liquid Standard
Ochratoxin

Ochratoxin A;
10 µg/ml in methanol

5 ml

TSL-504

OCHRASTANDARD

Ochratoxin A standard solution at a concentration
of 1000 ng/ml in methanol

6 ml
3 ml

RBRP11
RBRP11A

30

Mycotoxins
Mycotoxin standards
Product

Description

Zearalenone

dried

Trilogy® Dried Standard
Zearalenon

Zearalenone

No. of tests/amount Art. No.
25 µg/ml after reconstitution

TS-401

liquid
Trilogy® Liquid Standard
Zearalenon

Zearalenone; 25 µg/ml in methanol

10 ml

TSL-401

ZEASTANDARD

Zearalenone standard solution at a concentration
of 1000 ng/ml in acetonitrile

3 ml

RBRP44A

DAS

dried

Trilogy® Dried Standard
Diacetoxyscirpenol (DAS)

Diacetoxyscirpenol (DAS)

100 µg/ml after reconstitution

TS-316

DON (Vomitoxin)

dried

Trilogy® Dried Standard
DON

Deoxynivalenol

50 µg/ml after reconstitution

TS-310

Trilogy® Dried Standard
Deoxynivalenol (DON)

Deoxynivalenol (DON)

100 µg/ml after reconstitution

TS-317

Trilogy® Dried Standard
3-Acetyl Deoxynivalenol

3-Acetyl Deoxynivalenol

100 µg/ml after reconstitution

TS-342

Trilogy® Dried Standard
15-Acetyl Deoxynivalenol

15-Acetyl Deoxynivalenol

100 µg/ml after reconstitution

TS-343

10 ml

TSL-317

100 µg/ml after reconstitution

TS-351

100/30 µg/ml
after reconstitution

TS-202

liquid
Trilogy® Liquid Standard
Deoxynivalenol (DON)

Deoxynivalenol (DON); 100 µg/ml in methanol

Fusarenon X

dried

Trilogy® Dried Standard
Fusarenon X

Fusarenon X

Fumonisins

dried

Trilogy® Dried Standard
Fumonisin B1, B2

Fumonisin B1, Fumonisin B2 (10:3)
liquid

Trilogy® Liquid Standard
Fumonisin B1, B2

Fumonisin B1, Fumonisin B2
100 µg/ml Fumonisin B1, 30 µg/ml Fumonisin B2
in acetonitrile/water (50/50)

2 ml

TSL-202

Trilogy® Liquid Standard
Fumonisin B1

Fumonisin B1;
100 µg/ml in acetonitrile/water (50/50)

5 ml

TSL-204

Trilogy® Liquid Standard
Fumonisin B2

Fumonisin B2;
100 µg/ml in acetonitrile/water (50/50)

2 ml

TSL-205

Neosolaniol

dried

Trilogy® Dried Standard
Neosolaniol

Neosolaniol

100 µg/ml after reconstitution

TS-328

Nivalenol

dried

Trilogy® Dried Standard
Nivalenol

Nivalenol

100 µg/ml after reconstitution

TS-344

31

R-Biopharm AG – Product catalogue 2017

Mycotoxins
Mycotoxin standards
Product

Description

T-2/HT-2

dried

No. of tests/amount Art. No.

Trilogy® Dried Standard
T-2 Toxin

T-2 Toxin

100 µg/ml
after reconstitution

TS-314

Trilogy® Dried Standard
HT-2 Toxin

HT-2 Toxin

100 µg/ml
after reconstitution

TS-333

liquid
Trilogy® Liquid Standard
T-2 Toxin

T-2 Toxin; 100 µg/ml in acetonitrile

5 ml

TSL-314

Trilogy® Liquid Standard
HT-2 Toxin

HT-2 Toxin; 100 µg/ml in acetonitrile

5 ml

TSL-333

Trichotehecenes - Multitoxins

liquid

Trilogy® Liquid Standard
Type A & B Trichothecenes

Type A & B Trichothecenes;
(Fusarenon X, Deoxynivalenol, Nivalenol, 3- & 15-Acetyl
DON, HT-2 Toxin, Diacetoxyscirpenol, T-2 Toxin,
Neosolaniol)
100 µg/ml in acetonitrile

2 ml

TSL-307

dried
Trilogy® Dried Standard
Type A Trichothecenes

Type A Trichothecenes
(Diacetoxyscirpenol, HT-2 Toxin, T-2 Toxin, Neosolaniol)

10 µg/ml
after reconstitution

TS-353

Trilogy® Dried Standard
Type B Trichothecenes

Type B Trichothecenes
(Fusarenon X, Deoxynivalenol, 3- & 15-Acetyl DON,
Nivalenol)

10 µg/ml
after reconstitution

TS-354

Citrinin

dried

Trilogy® Dried Standard
Citrinin

Citrinin

5 µg/ml
after reconstitution

TS-904

Cyclopiazonic acid

dried

Trilogy® Dried Standard
Cyclopiazonic Acid

Cyclopiazonic acid

10 µg/ml
after reconstitution

TS-802

Patulin

liquid

Trilogy® Liquid Standard
Patulin

Patulin; 25 µg/ml in acetonitrile

5 ml

TSL-601

32

Mycotoxins
Reference material for mycotoxin analysis
Product

Description

Reference material

Food or feed product

No. of tests/amount Art. No.

Trilogy® Certified Reference Material
Aflatoxin

Commodities available upon request

100 gram
500 gram
1000 gram

TR-A100
TR-A500
TR-A1000

Trilogy® Certified Reference Material
Ochratoxin

Commodities available upon request

100 gram
500 gram
1000 gram

TR-O100
TR-O500
TR-O1000

Trilogy® Certified Reference Material
Zearalenon

Commodities available upon request

100 gram
500 gram
1000 gram

TR-Z100
TR-Z500
TR-Z1000

Trilogy® Certified Reference Material
Deoxynivalenol

Commodities available upon request

100 gram
500 gram
1000 gram

TR-D100
TR-D500
TR-D1000

Trilogy® Certified Reference Material
Fumonisin

Commodities available upon request

100 gram
500 gram
1000 gram

TR-F100
TR-F500
TR-F1000

Trilogy® Certified Reference Material
Multitoxin

Commodities and mycotoxins available upon request

100 gram
500 gram
1000 gram

TR-MT100
TR-MT500
TR-MT1000

Trilogy® Certified Reference Material
Complex commodities;
Single & Multitoxin

Commodities and mycotoxins available upon request

100 gram
500 gram
1000 gram

TR-CC100
TR-CC500
TR-CC1000

33

R-Biopharm AG – Product catalogue 2017

Analysis of hormone &
anabolic residues in food
Hormones and anabolics can be used as growth promoters in
livestock breeding to enhance average daily weight gain and
meat/fat ratio. As a consequence, hormone and anabolic residues
can occur in food of animal origin.
Due to their systemic function, hormonal
residues in food bear a potential health risk
for the consumer.
Additionally, the entry of hormonal active
substances into surface and ground water
can have an ecological impact on aquatic
ecosystems.

RIDASCREEN®
• ELISAs for the most commonly
used hormones and anabolics
• Quantitative Screening
• Applications for many matrices
• Evaluation with RIDA®SOFT Win

34

Consequently, most countries have banned
the use of hormones and anabolics in
livestock breeding completely with
exceptions for veterinary purposes.

Hormones & Anabolics
Product

Description

β-Agonists

ELISA microtiter plates

No. of tests/amount Art. No.

RIDASCREEN® β-Agonists

Enzyme immunoassay for quantitative analysis of β-agonists
in urine (150 ng/l), serum (900 ng/l),
meat (100 ng/kg), liver (130 ng/kg), milk (45 ng/l),
feed (1000 ng/kg)

96 determinations
Incubation time: 1 hr

R1704

RIDASCREEN® Clenbuterol

Enzyme immunoassay for quantitative analysis of clenbuterol
in milk (50 ng/l), meat (100 ng/kg), liver (150 ng/kg),
kidney (200 ng/kg), urine (100 ng/l), plasma/serum (250 ng/l),
hair (2 µg/kg), eye ball (200 ng/kg), feed (600 µg/kg)

96 determinations
Incubation time: 1 hr

R1711

RIDA® β-Agonists & Clenbuterol
Spiking Solution

100 ng/ml

1 ml

R1799

Clenbuterol Assay Control (positive)

Freeze-dried calves urine positive for clenbuterol

1 x 5 ml

R1707

Clenbuterol Assay Control (negative)

Freeze-dried calves urine negative for clenbuterol

1 x 2 ml

R1708

RIDASCREEN® Ractopamin

Enzyme immunoassay for quantitative analysis of
ractopamine in urine (600 ng/l), meat (200 ng/kg),
liver (300 ng/kg), *

96 determinations
Incubation time: 1 hr 30 min

R9901

RIDA® Ractopamin Spiking Solution

10 ng/ml

1 ml

R9999

Stilbenes

ELISA microtiter plates

RIDASCREEN® DES

Enzyme immunoassay for quantitative analysis of DES in
urine (200 ng/l), meat/feces (100 ng/kg), bile (2 µg/l), *

96 determinations
Incubation time:
over night and 1 hr 30 min

R2701

RIDA® DES Spiking Solution

10 ng/ml

1 ml

R2799

DES Assay Control (positive)

Freeze-dried calves urine positive for DES

1 x 5 ml

R2707

DES Assay Control (negative)

Freeze-dried calves urine negative for DES

1 x 5 ml

R2708

Sex hormones

ELISA microtiter plates

RIDASCREEN® 17β-Östradiol

Enzyme immunoassay for quantitative analysis of
17 β-estradiol in bovine plasma (20 ng/l), *

96 determinations
Incubation time: 2 hrs 30 min

R2301

RIDA® 17β-Östradiol Spiking Solution

200 ng/ml

1 ml

R2399

RIDASCREEN® Testosteron

Enzyme immunoassay for quantitative analysis of
testosterone in bovine plasma (20 ng/l), *

96 determinations
Incubation time: 2 hrs 30 min

R2401

RIDA® Testosteron Spiking Solution

500 ng/ml

1 ml

R2499

* Further applications on request.

35

R-Biopharm AG – Product catalogue 2017

Hormones & anabolics
Product

Description

Gestagens

ELISA microtiter plates

RIDASCREEN® Acetylgestagene

Enzyme immunoassay for quantitative analysis of
medroxyprogesterone acetate in bovine perirenal fat
(300 ng/kg)

96 determinations
Incubation time: 2 hrs 30 min

R1801

RIDA® Acetylgestagene
Spiking Solution

100 ng/ml medroxyprogesterone acetate

1 ml

R1899

RIDASCREEN® Melengestrolacetat

Enzyme immunoassay for quantitative analysis of
melengestrolacetate in bovine renal fat (300 ng/kg),
meat (75 ng/kg)

96 determinations
Incubation time: 2 hrs 30 min

R6502

RIDA® Melengestrolacetat
Spiking Solution

100 ng/ml

1 ml

R6599

Anabolic steroids

ELISA microtiter plates

RIDASCREEN® Trenbolon

Enzyme immunoassay for quantitative analysis of trenbolone
in urine (400 ng/l), bile (1 µg/l), meat/liver (200 ng/kg),
feces (25 ng/kg), *

96 determinations
Incubation time: 2 hrs 30 min

R2601

RIDA® Trenbolon Spiking Solution

50 ng/ml

1 ml

R2699

Trenbolone Assay Control
(negative)

Freeze-dried calves urine negative for trenbolone

1 x 5 ml

R2608

RIDASCREEN® Methyltestosteron

Enzyme immunoassay for quantitative analysis of
methyltestosterone in porcine urine (540 ng/l),
bovine urine (750 ng/l), beef (450 ng/kg), pork (390 ng/kg),
fish (430 ng/kg), porcine liver (180 ng/kg),
bovine liver (720 ng/kg)

96 determinations
Incubation time: 2 hrs 15 min

R3611

RIDA® Methyltestosteron
Spiking Solution

100 ng/ml

1 ml

R3699

RIDASCREEN®
19-Nortestosteron

Enzyme immunoassay for quantitative analysis of
19-nortestosterone in urine (3 µg/l), *

96 determinations
Incubation time: 1 hr 15 min

R2801

RIDA® 19-Nortestosteron
Spiking Solution

1 µg/ml

1 ml

R2899

RIDASCREEN® Ethinylöstradiol

Enzyme immunoassay for quantitative analysis of
ethinylestradiol in bovine/porcine urine (370 ng/l),
beef (230 ng/kg), pork (200 ng/kg),
bovine plasma (50 ng/l)

96 determinations
Incubation time: 2 hrs 30 min

R2511

RIDA® Ethinylöstradiol
Spiking Solution

20 ng/ml

1 ml

R2599

Non-steroidal compounds

ELISA microtiter plates

RIDASCREEN® Zeranol

Enzyme immunoassay for quantitative analysis of
zeranol in urine (1.5 µg/l), *

96 determinations
Incubation time: 1 hr 15 min

R3301

RIDA® Zeranol Spiking Solution

20 ng/ml

1 ml

R3399

Accessories

Solid phase columns

RIDA® C18 columns

Solid phase extraction columns for use in conjunction
with RIDASCREEN® ELISAs

100 columns

R2002

* Further applications on request.

36

No. of tests/amount Art. No.

37

R-Biopharm AG – Product catalogue 2017

Analysis of antibiotic residues
In addition to their function as veterinary drugs, antibiotics can be
used as antimicrobial growth promoters in livestock breeding. As a
consequence of incorrect or illegal use, antibiotic drug residues in
food of animal origin can remain.
Because of the potentially toxic,
carcinogenic and allergic properties of
antibiotic residues, contaminated food is a
direct health risk for consumers.
Additionally, the inappropriate use of
antibiotics in animal husbandry and food
production can promote multi-resistant
pathogens, which pose an increasing risk
for public health.

38

For these reasons, most countries have
established Maximum Residue Limits
(MRLs) and monitoring programs for
antibiotic residues in food. Non-compliance
with these legislations e.g. in export can
lead to severe penalties.
For biotechnological industries, antibiotic
residues bear additionally a technological
and economic risk, as they can inhibit
production processes involving
microorganisms and thus lead to
production losses.

RIDASCREEN®
ELISAs for qualitative screening
• Quantitative results of single antibiotics
or antibiotic groups
• Detects the most commonly used
antibiotics
• Applications for a wide range of matrices
• Evaluation with RIDA®SOFT Win

EASI-EXTRACT®/RIDA®
Immunoaffinity columns for
sample clean-up
• For ELISA, HPLC or LC-MS/MS-analysis
• For complex matrices such as honey
• Reduced interferences
• Excellent recovery

Premi®Test
Microbial inhibition test for
qualitative screening
• Detects a broad spectrum of antibiotics
• Easy to handle, no sophisticated
equipment needed
• Fast (-er than plate tests)
• Sensitive (in conformity with EU-MRLs)
• Validated (AOAC-RI PTMSM and
AFNOR NF VALIDATION)

39

R-Biopharm AG – Product catalogue 2017

Antibiotics
Product

Description

Fenicols

ELISA microtiter plates

RIDASCREEN® Chloramphenicol

Enzyme immunoassay for quantitative analysis of
chloramphenicol in milk (24 ng/l), milk powder (25 ng/kg),
joghurt/kefir/buttermilk/cream (12 ng/kg),
curd/sour cream (15 ng/kg), butter (61 ng/kg),
cheese (16 ng/kg), honey (25 ng/kg), royal jelly (23 ng/kg),
meat (5 ng/kg), fish/shrimp (8 ng/kg), egg (15 ng/kg),
urine (196 ng/l), plasma/serum (18 ng/l), feed (107 ng/kg)

96 determinations
Incubation time: 45 min

R1511

RIDA® Chloramphenicol
Spiking Solution

50 ng/ml

1 ml

R1599

Fenicols

Immunoaffinity columns

EASI-EXTRACT® CHLORAMPHENICOL

Immunoaffinity columns for sample clean-up prior to the
analysis of chloramphenicol using HPLC or LC-MS/MS

10 columns (3 ml format)
50 columns (3 ml format)

RBRP300
RBRP300B

Tetracyclins

ELISA microtiter plates

RIDASCREEN® Tetracyclin

Enzyme immunoassay for quantitative analysis of
tetracycline in milk (0.9 µg/l), milk powder (5 µg/kg),
cheese (2.3 µg/kg), butter (2.6 µg/kg), dairy products (1 µg/kg),
honey (3.7 µg/kg), meat (1.5 µg/kg), sausage (4.6 µg/kg),
fish (1.5 µg/kg), shrimp (1.2 µg/kg), eggs (2.8 µg/kg)

96 determinations
Incubation time: 1 hr 30 min

R3505

RIDA® Tetracyclin
Spiking Solution

Lyophilisate, produces 10 ml of a 100 ng/ml stock solution

1 lyophilisate,
1 reconstitution buffer

R3599

β-Lactame

ELISA microtiter plates

RIDASCREEN® Penicillin

Enzyme immunoassay for quantitative analysis of penicillins
milk (0.2 µg/l), cheese/butter/yoghurt/curd/cream/sour
cream/kefir/whey (0.9 - 2.1 µg/l or µg/kg), infant formula
(0.3 µg/l), serum (0.4 µg/l), meat (2.6 µg/kg)

96 determinations
Incubation time: 1 hr 30 min

R2921

40

No. of tests/amount Art. No.

Antibiotics
Product

Description

Nitrofurans

ELISA microtiter plates

No. of tests/amount Art. No.

RIDASCREEN® Nitrofuran (AOZ)

Enzyme immunoassay for quantitative analysis of AOZ in
shrimp/fish/milk (50 ng/kg), meat/liver/whole egg/honey
(100 ng/kg), *

96 determinations
Incubation time: 1 hr 15 min

R3703

RIDA® Nitrofuran (AOZ)
Spiking Solution

20 ng/ml

1 ml

R3798

RIDASCREEN® Nitrofuran (AMOZ)

Enzyme immunoassay for quantitative analysis of AMOZ in
shrimp/meat/liver/fish/whole egg (200 ng/kg), *

96 determinations
Incubation time: 1 hr 15 min

R3711

RIDA® Nitrofuran (AMOZ)
Spiking Solution

20 ng/ml

1 ml

R3799

RIDASCREEN® Nitrofuran (AHD)

Enzyme immunoassay for quantitative analysis of AHD
in shrimp (200 ng/kg), fish (76 ng/kg), *

96 determinations
Incubation time: 1 hr 15 min

R3713

RIDA® Nitrofuran (AHD)
Spiking Solution

20 ng/ml

1 ml

R3796

RIDASCREEN® Nitrofuran (SEM)

Enzyme immunoassay for quantitative analysis of SEM
in meat beef/pork/shrimp (300 ng/kg),
poultry (400 ng/kg), fish 360 ng/kg), *

96 determinations
Incubation time: 1 hr 15 min

R3715

RIDA® Nitrofuran (SEM)
Spiking Solution

20 ng/ml

1 ml

R3797

Aminoglycosides

ELISA microtiter plates

RIDASCREEN® Streptomycin

Enzyme immunoassay for quantitative analysis of
streptomycin in milk (5 µg/l), honey (2 µg/kg),
beef/pork (22 µg/kg), poultry (28 µg/kg), liver (23 (µg/kg),
kidney (18 µg/kg), shrimp (20 µg/kg), apple juice (4 µg/l)

96 determinations
Incubation time: 1 hr 15 min

R3103

RIDA® Streptomycin
Spiking Solution

10 μg/ml

1 ml

R3199

Sulfonamides

ELISA microtiter plates

RIDASCREEN® Sulfamethazin

Enzyme immunoassay for quantitative analysis of
sulfamethazine in milk (4 µg/l), meat/kidney (18 µg/kg), *

96 determinations
Incubation time: 2 hrs 30 min

R3001

RIDA® Sulfamethazin
Spiking Solution

10 µg/ml

1 ml

R3098

RIDASCREEN® Sulfonamide

Enzyme immunoassay for quantitative analysis of
sulfonamides in poultry/egg (1.5 µg/kg),
pork/fish/shrimps/honey (2 µg/kg), milk (3.5 µg/l)

96 determinations
Incubation time: 1 hr 15 min

R3004

RIDA® Sulfonamide/
Sulfamethoxypyridazin
Spiking Solution

0.1 μg/ml

1 ml

R3099

* Further applications on request.

41

R-Biopharm AG – Product catalogue 2017

Antibiotics
Product

Description

Quinolones

ELISA microtiter plates

RIDASCREEN®
Chinolone/Quinolones

Enzyme immunoassay for quantitative analysis of
quinolones in shrimp (6 µg/kg), fish (8 µg/kg),
egg (9 µg/kg), meat (10 µg/kg), *

96 determinations
Incubation time: 1 hr 15 min

R3113

RIDA® Ciprofloxacin
Spiking Solution

1 µg/ml

1 ml

R3198

Polypeptides

ELISA microtiter plates

RIDASCREEN® Bacitracin

Enzyme immunoassay for quantitative analysis of
bacitracin in milk (11 µg/l), meat (9 µg/kg), eggs (11 µg/kg),
feed (82 µg/kg), urine (23 µg/l)

96 determinations
Incubation time: 1 h 30 min

R2901

Premi®Test

Test ampoules

Premi®Test

Microbial inhibition test for the screening of antibiotic
residues in food of animal origin such as meat (beef, pork,
poultry), liver, kidney, fish, shrimp, eggs, bovine/porcine
urine and pork/poultry feed
Detectable antibiotic groups: β-lactams, cephalosporins,
macrolides, tetracyclins, sulphonamides, aminoglycosides,
quinolones, polypeptides, fenicols, others

4 x 25 ampoules
25 ampoules
Incubation time: 3 hrs

R3900
R3925

Premi®Test

Reagent

Premi®Test Urin

Reagent for the preparation of bovine and porcine urine
samples for the screening of antibiotic residues with
Premi®Test

1 dropper bottle containing
15 ml,
sufficient for 30 samples with a
sample volume of 30 ml each

R3921

* Further applications on request.

42

No. of tests/amount Art. No.

Phycotoxins
Product

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN® FAST PSP SC

Enzymimmunoassay for quanitative analysis of
saxitoxin and related algae toxins in mussels;
Detection limit: 50 µg/kg

48 determinations
Incubation time: 30 min

R1905

48 determinations
Incubation time: 1 hr 30 min

R4302

Food adulteration
ELISA microtiter plates
RIDASCREEN® CIS

Enzyme immunoassay for the analysis of cow‘s milk
(bovine IgG) in sheep and goat’s milk and cheese;
Detection limit: 0.1 % (cow‘s milk in sheep/goat‘s milk/
cheese)
Test strips

RIDA®QUICK CIS

Immunochromatographic test for the detection of
cow’s milk (bovine IgG) in milk or cheese of other species;
Detection limit: 0.5 % (cow’s milk in sheep/goat’s milk/
cheese)

25 strips
Incubation time: 5 min

R4303

DUROTEST® S

Membrane strips for detection of non-durum wheat
adulteration in semolina
Detection limit: 3 % non-durum wheat.

20 strips
(80 determinations)

RBRP10

25 columns

RBRP111

96 determinations
Incubation time: 15 min

R1605

1 Set (200 wine samples)

R1699

96 determinations
48 determinations
Incubation time: 1 hr 15 min

R1601
R1604

48 determinations
Incubation time: 5 min

R1603

Solid phase column
MELAMINE
CLEAN-UP COLUMN

Solid phase column for sample clean-up prior to the analysis
of melanine using HPLC or LC-MS/MS
Detection limit: 15.625 ng/ml melamine

Histamine
Histamine

Enzymatic test microtiter plates

RIDASCREEN® Histamine (enzymatic)

Enzymatic test in microtiter plate format for the quantitative
determination of histamine in fish, canned fish, fish meal,
wine, cheese and milk; for the sample preparation of wine it
is recommended to use RIDA® Sample Decolorant (R1699)
Detection limit: 0.75 - 3.75 mg/kg (ppm) histamine
depending on matrix
Accessories

RIDA® Sample Decolorant

Reagents for the sample extraction of wine for
histamine analysis
ELISA microtiter plates

RIDASCREEN® Histamin

Competitive ELISA to quantify histamine in food;
Detection limit: 0.1 - 100 mg/kg histamine
depending on matrix
Colorimetric assay for quantitative analysis

RIDA®QUICK Histamin

Colorimetric assay to quantify histamine in fish meal
and fresh fish
Detection limit: 0.1 - 100 mg/kg histamine
depending on matrix

43

R-Biopharm AG – Product catalogue 2017

Allergen analysis of food and
surfaces with sensitive test kits
Even small traces of allergenic proteins in food can provoke allergic
reactions in sensitive people. Therefore monitoring of
cross-contamination in raw material and production lines as well as
correct labeling of food products are an important part of quality
control in the food industry.
Surface and hygiene control

Product testing

Clean and controlled allergen production
conditions are a prerequisite for allergenfree food products. Therefore swabs within
production sites should be carried out
regularly with Test strips from bioavid or
RIDA®QUICK. No lab equipment is
required and results from these rapid tests
are available within 5 - 10 minutes.

For food testing different analytical
methods exist: ELISA, LFD and PCR. While
an ELISA and LFD detect proteins; PCR
detects DNA. These methods are
complementary and can be used for
confirmation of screening results. The
unique multiplex real-time PCR allows the
detection of 3 parameters plus internal
amplification control in one run.

44

bioavid/RIDA®QUICK
•
•
•
•
•

On-site testing (swab test, food)
Simple
No lab equipment required
Rapid yes/no decision
Food after validation

RIDASCREEN® ELISA
• Quantitative results using certified
calibration material (e.g. NIST CRM)
• Simple sample preparation (20 min)
and test procedure (3 x 10 min)
• Possibility of using automates
(ThunderBolt®, GEMINI)
• Evaluation with the software
RIDA®SOFT Win

SureFood® PCR
• Robust, stable target molecule (DNA) in
highly processed food samples
• Highly specific assay with minimum
tendency to cross-reactions
• One sample preparation using
SureFood® PREP Advanced (S1053)
for all parameters in 90 minutes
• Customized solutions
• Standardized handling and test procedure
(1 - 2 hours)

45

R-Biopharm AG – Product catalogue 2017

Allergens
Gliadin/Gluten
Product

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN® Gliadin
AOAC-OMA 2012.01“Final Action“
AOAC-RI 120601
AACCI 38-50.01
Codex Alimentarius
Method (Type I)
ICC

Official R5 Mendez method: Sandwich ELISA to quantify
prolamines from wheat, rye and barley in e.g. food declared
as gluten-free; sample extraction with R7006 or R7016
(not contained in the kit); the kit is suitable for automation;
Detection limit: 0.5 mg/kg gliadin or 1.0 mg/kg gluten

96 determinations
Incubation time: 1 hr 30 min

R7001

RIDASCREEN®FAST Gliadin

R5 sandwich ELISA to quantify prolamines from wheat, rye,
barley in e.g. food declared as gluten-free; sample extraction
with R7006 or R7016 (not contained in the kit);
Detection limit: 0.5 mg/kg gliadin or 1.0 mg/kg gluten

48 determination
Incubation time: 30 min

R7002

RIDASCREEN® Gliadin competitive
(2nd generation)
AACCI 38-55.01
AOAC-OMA 2105.05

R5 competitive ELISA to quantify potential toxic peptide
sequences of prolamines from wheat, rye and barley in
fermented and hydrolyzed food (e.g. beer, starch, starch
syrup, malt extracts); sample preparation with an ethanolic
solution; the standard material is a hydrolyzate (mixture of
wheat, rye and barley); the results can be related to the limit
values of the Codex Alimentarius
Detection limit: 2.3 mg/kg gliadin or 4.6 mg/kg gluten

96 determinations
Incubation time: 40 min

R7021

ELISA – accessories
Cocktail (patented)

Developed by Prof. Mendez; officially recommended
extraction buffer for all processed e.g. heat treated food
samples in conjunction with R7001, R7002, R7003, R7004

105 ml

R7006

Cocktail (patented)

Corresponding to R7006 but larger bottle size

1000 ml

R7016

RIDA® Extraction Solution
(colorless)

Alternative to the Cocktail (patented) (use only after
extraction comparision with Cocktail): The extraction is faster
(35 min compared to 1 h 50 min with the cocktail); it is used
in conjunction with R7001, R7002, R7003 and R7004

105 ml

R7098

Set of 3 processed Gliadin
Assay Controls

Three assay controls: 3 positive
homogenized processed snack samples for the
determination with sandwich ELISA;
produced by Trilogy® Analytical Laboratories

3 x 1.5 g

R7012

Lateral flow test strips
RIDA®QUICK Gliadin
AOAC-OMA 2015.16
AACCI

The immunochromatographic test is based on the R5
antibody and detects prolamines from wheat, rye and barley;
the Test strips can be used directly for swabs on surfaces or
for analysis of e.g. gluten-free raw materials
Detection limit: 1-2 μg gliadin/100 cm2 on surfaces,
2.2 mg/kg gliadin in raw materials, 3.1 mg/kg gliadin in
processed food

25 Test strips in reclosable
tube,
25 plastic pipettes, sample
diluent (ready-to-use),
30 vials
Incubation time: 5 min

R7003

RIDA®QUICK Gliadin
(single packaged)

Corresponding to 7003, Test strips are single
packaged and no plastic pipettes are included

25 Test strips single packed,
sample diluent (ready-to-use),
30 vials
Incubation time: 5 min

R7004

RIDA®QUICK Gliadin
(ready to swab)

Corresponding to R7003, Test strips are single
packaged, prefilled vials with ready-to-use sample
buffer are included

25 Test strips single packed,
25 prefilled vials with
ready-to-use buffer

R7005

46

Allergens
Gluten
Product

Description

No. of tests/amount Art. No.

Real-time PCR – qualitative DNA detection
SureFood® ALLERGEN ID Gluten

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

100 reactions*

S3106

100 reactions**

S3206

48 determinations
Incubation time: 30 min

R7102

3x2g

R7132

Real-time PCR – quantitative DNA detection
SureFood® ALLERGEN QUANT
Gluten

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 1 mg/kg
depending on matrix and DNA preparation

Soy
ELISA microtiter plates
RIDASCREEN®FAST Soya

Sandwich ELISA to quantify traces of soy protein in
native and processed food; the kit is suitable for automation;
Detection limit: 0.24 mg/kg, the kit is suitable for automation
ELISA – accessories

Set of 3 processed
Soya Assay Controls

Three assay controls: 1 negative, 2 positive
homogenized processed cookies;
produced by Trilogy® Analytical Laboratories

A
SOY A
SOY A
YA
PLE
SOY
SO YA
SAM PLE
SO YA
A
SAM PLE
LE A
SO
SOY
SAM
MP
LEA
SOY
YA
LE
PLE SA MP
SOY
SO YA
MP
SAM PLE SA
SO YA
SAM PLE SA
A
LE
SO
SOY
SAM
A
MP
LE
SA SOY
A
MP LE
YA
PLE SA
SOY
SOYA
SO YA
SAMLE
PLE SAMP
SO YA
SAMP
SAMLEPLE SOYA
LE
SO
SOYA
SAM
SAMP
MP
LE
SA MPLE
SAMP
SA MPLE
SOYA
SA
LE
SOYA
SAMP LE
SOYA
SAMP LE
SAMP

Lateral flow test strips
RIDA®QUICK Soya

Immunochromatographic test for the determination of soya
on surfaces, also strongly heated soya samples were
detected. It is recommended to use RIDA®QUICK Soya
accessory pack (Z7103) for sample preparation.
Detection limit: approx. 0.5 µg soya protein/100 cm²

25 dip sticks in reclosable
tube, Conjugate,
Extraction buffer,
30 Plastic tubes, 25 Tubes,
26 Swabs, 50 pipette tips
Incubation time: 16 min

R7103

Accessories for the use of the RIDA®QUICK Soya

Test tube holder,
floating rack, pipette

Z7103

The buffer is used for food sample preparation

2 x 100 ml

R7113

100 reactions*

S3101

100 reactions**

S3201

LE
SAMP LE
SAMP LE
SAMP

SOYA
SOYA
SOYA

RIDA®QUICK Soya
RIDA®QUICK Soya accessory pack
RIDA®QUICK Soya Extraction buffer

Real-time PCR – qualitative DNA detection
SureFood® ALLERGEN ID Soya

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood® ALLERGEN QUANT Soya

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 1 mg/kg
depending on matrix and DNA preparation

* Includes additional 100 reactions of Inhibition Control Mix (ICM).
** SureFood® QUANTARD Allergen 40 must be used for quantification.

47

R-Biopharm AG – Product catalogue 2017

Allergens
Milk
Produkt

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN®FAST Milk
AOAC-RI 101501

Sandwich ELISA to quantify milk proteins (casein and
ß-lactoglobulin) in food containing traces of milk
components; the assay is calibrated to NIST SRM 1549a
whole milk powder; the kit is suitable for automation;
Detection limit: 0.7 mg/kg milk protein

48 determinations
Incubation time: 30 min

R4652

RIDASCREEN®FAST Casein
(2nd generation)

Sandwich ELISA to quantify casein in food containing
traces of milk or casein/caseinates;
the kit is suitable for automation;
Detection limit: 0.12 mg/kg casein in ice cream,
chocolate, beverages and 0.71 mg/kg casein for all other
samples (extraction with Extractor 2)

48 determinations
Incubation time: 30 min

R4612

RIDASCREEN®FAST ß-Lactoglobulin

Sandwich ELISA to quantify native and processed
ß-lactoglobulin in food containing traces of milk or whey;
the kit is suitable for automation;
Detection limit: 0.19 mg/kg ß-lactoglobulin

48 determinations
Incubation time: 30 min

R4902

RIDASCREEN® ß-Lactoglobulin

Competitive ELISA to quantify native and processed
ß-lactoglobulin in hydrolyzed milk products
(e.g. hypoallergenic baby food);
Detection limit: 0.1 mg/kg ß-lactoglobulin

96 determinations
Incubation time: 2 hrs 45 min

R4901

30 ml concentrate,
sufficient for 15 samples

R4613

10 Test strips
25 Test strips
Incubation time: 8 min

BL613-10
BL613-25

ELISA – accessories
RIDA® Extractor 2

The RIDA® Extractor 2 (R4613) is used for the sample
preparation in
• RIDASCREEN®FAST Milk (R4652)
• RIDASCREEN®FAST Casein (R4612)
• RIDASCREEN®FAST ß-Lactoglobulin (R4902).
Lateral flow test strips

bioavid
Lateral Flow Milch/Milk

Immunochromatographic tests for qualitative detection
of milk;
Detection limit: 1 mg/kg depending on matrix
Reference material

MoniQA Milk Reference Material Blank

Gluten free cookie, milled, free from gluten, milk, egg, soy,
peanut, tree-nuts, Negative Control and/or Matrix Material
as basis for spiked samples
Prepared and packaged by Trilogy Analytical Laboratories

1x5g

MQA 082015

MoniQA Milk Reference Material SMP

Dried skim milk powder, characterized, Positive Control and/
or use for spiked samples
Prepared and packaged by Trilogy Analytical Laboratories

1x5g

MQA 092014

MoniQA Milk Reference Material Low

Dried skim milk powder incurred in gluten free cookies,
milled, concentration approx. 10 ppm
Prepared and packaged by Trilogy Analytical Laboratories

1x5g

MQA 102016

MoniQA Milk Reference Material High

Dried skim milk powder incurred in gluten free cookies,
milled, concentration approx. 50 ppm
Prepared and packaged by Trilogy Analytical Laboratories

1x5g

MQA 082016

Set of 4
MoniQA Milk Reference controls Blank, SMP, High, Low

Set includes each pouch of
MQA 082015, MQA 092014, MQA 092016, MQA 082016
Prepared and packaged by Trilogy Analytical Laboratories

4x5g

MQA 122016

48

Allergens
Egg
Produkt

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN® FAST Ei/Egg Protein

Sandwich ELISA to quantify traces of whole egg powder in
food; the assay is calibrated to NIST SRM 8445 whole egg
powder; no cross-reactivity to chicken meat (raw and cooked);
the kit is suitable for automation;
Detection limit: 0.1 mg/kg whole egg powder,
0.03 mg/kg egg white protein

48 determinations
Incubation time: 30 min

R6402

RIDASCREEN®FAST Lysozym

Sandwich ELISA to quantify traces of lysozyme in wine,
cheese and sausage;
Detection limit: 0.006 mg/kg lysozyme in wine,
0.016 mg/kg lysozyme in cheese and sausages

48 determinations
Incubation time: 30 min

R6452

10 Test strips
25 Test strips
Incubation time: 8 min

BL608-10
BL608-25

48 determinations
Incubation time: 30 min

R6901

10 Test strips
25 Test strips
Incubation time: 10 min

BL601-10
BL601-25

100 reactions*

S3104

25 Test strips
Incubation time: 10 min

BL602-25

100 reactions*

S3117

48 determinations
Incubation time: 30 min

R6872

10 Test strips
25 Test strips
Incubation time: 10 min

BL610-10
BL610-25

100 reactions*

S3115

Lateral flow test strips
bioavid
Lateral Flow Ei/Egg

Immunochromatographic tests for qualitative detection
of egg;
Detection limit: 1 mg/kg depending on matrix

Nuts
Almond

ELISA microtiter plates

RIDASCREEN®FAST
Mandel/Almond

Sandwich ELISA to quantify traces of almond in food;
Detection limit: 1.2 mg/kg almond
Lateral flow test strips

bioavid Lateral Flow Almond

Immunochromatographic tests for qualitative detection
of almond;
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Almond

Detection limit: ≤ 4 mg/kg;
depending on matrix and DNA preparation

Brazil nut

Lateral flow test strips

bioavid Lateral Flow Brazil nut

Immunochromatographic tests for qualitative detection
of brazil nut;
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Brazil nut

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

Cashew kernel

ELISA microtiter plates

RIDASCREEN®FAST Cashew

Sandwich ELISA to quantify traces of cashew in food;
Detection limit: 0.09 mg/kg cashew
Lateral flow test strips

bioavid Lateral Flow Cashew Kernel

Immunochromatographic tests for qualitative detection
of cashew kernel;
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Cashew

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

* Includes additional 100 reactions of Inhibition Control Mix (ICM).
** SureFood® QUANTARD Allergen 40 must be used for quantification.

49

R-Biopharm AG – Product catalogue 2017

Allergens
Nuts
Product

Description

Coconut

Lateral flow test strips

bioavid Lateral Flow Coconut

Immunochromatographic tests for qualitative detection
of coconut;
Detection limit: 1 mg/kg depending on matrix

Hazelnut

ELISA microtiter plates

RIDASCREEN®FAST Hazelnut
DIN CEN/TS 15633-2 method

Sandwich ELISA to quantify traces of hazelnut in food;
Detection limit: 1.5 mg/kg hazelnut

No. of tests/amount Art. No.
10 Test strips
25 Test strips
Incubation time: 10 min

BL600-10
BL600-25

48 determinations
Incubation time: 30 min

R6802

10 Test strips
25 Test strips
Incubation time: 10 min

BL604-10
BL604-25

100 reactions*

S3102

100 reactions**

S3202

48 determinations
Incubation time: 30 min

R6852

10 Test strips
25 Test strips
Incubation time: 10 min

BL605-10
BL605-25

100 reactions*

S3116

100 reactions*

S3118

48 determinations
Incubation time: 30 min

R6202

10 Test strips
25 Test strips
Incubation time: 10 min

BL606-10
BL606-25

100 reactions*

S3103

100 reactions**

S3203

Lateral flow test strips
bioavid Lateral Flow Hazelnut

Immunochromatographic tests for qualitative detection
of hazelnut;
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Hazelnut

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood® ALLERGEN QUANT
Hazelnut

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 1 mg/kg
depending on matrix and DNA preparation

Macadamia nut

ELISA microtiter plates

RIDASCREEN®FAST Macadamia

Sandwich ELISA to quantify traces of macadamia in food;
Detection limit: 0.38 mg/kg macadamia
Lateral flow test strips

bioavid
Lateral Flow Macadamia nut

Immunochromatographic tests for qualitative detection
of macadamia nut;
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID
Macadamia nut

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

Pecan nut

Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Pecan

Detection limit: ≤ 4 mg/kg;
depending on matrix

Peanut

ELISA microtiter plates

RIDASCREEN®FAST Peanut
AOAC-RI 030404

Sandwich ELISA to quantify traces of peanut in food;
the assay is calibrated to NIST SRM 2387 peanut butter
Detection limit: 1.3 mg/kg peanut
Lateral flow test strips

bioavid
Lateral Flow Peanut

Immunochromatographic tests for qualitative detection
of peanut;
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID
Peanut

Detection limit: ≤ 1 mg/kg;
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood®
ALLERGEN QUANT
Peanut

Detection limit: ≤ 1 mg/kg
Quantification limit: 4 mg/kg
depending on matrix and DNA preparation

* Includes additional 100 reactions of Inhibition Control Mix (ICM).
** SureFood® QUANTARD Allergen 40 must be used for quantification.

50

Allergens
Nuts
Product

Description

Pistachio

Lateral flow test strips

bioavid
Lateral Flow Pistachio

Immunochromatographic tests for qualitative detection
of pistachio;
Detection limit: 1 mg/kg depending on matrix

No. of tests/amount Art. No.
10 Test strips
25 Test strips
Incubation time: 10 min

BL611-10
BL611-25

100 reactions*

S3114

100 reactions**

S3214

10 Test strips
25 Test strips
Incubation time: 10 min

BL607-10
BL607-25

100 reactions*

S3107

100 reactions**

S3207

48 determinations
Incubation time: 30 min

R7202

10 Test strips
25 Test strips
Incubation time: 10 min

BL609-10
BL609-25

100 reactions*

S3108

100 reactions**

S3208

Real-time PCR – qualitative DNA detection
SureFood® ALLERGEN ID
Pistachio

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood®
ALLERGEN QUANT
Pistachio

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 1 mg/kg
depending on matrix and DNA preparation

Walnut

Lateral flow test strips

bioavid
Lateral Flow Walnut

Immunochromatographic tests for qualitative detection
of walnut and pecan nut;
Detection limit: 10 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID
Walnut

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood®
ALLERGEN QUANT
Walnut

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 1 mg/kg
depending on matrix and DNA preparation

Oil plants
ELISA microtiter plates
RIDASCREEN®FAST Sesame

Sandwich ELISA to quantify traces of sesame in food;
Detection limit: 0.2 mg/kg sesame
Lateral flow test strips

bioavid
Lateral Flow Sesam/Sesame

Immunochromatographic tests for qualitative detection
of sesame
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID
Sesame

Detection limit: ≤ 0.4 mg/kg
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood® ALLERGEN QUANT
Sesame

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 1 mg/kg
depending on matrix and DNA preparation

* Includes additional 100 reactions of Inhibition Control Mix (ICM).
** SureFood® QUANTARD Allergen 40 must be used for quantification.

51

R-Biopharm AG – Product catalogue 2017

Allergens
Fish/Crustacean/Seafood
Product

Description

No. of tests/amount Art. No.

ELISA microtiter plates
RIDASCREEN®FAST Crustacean
(2nd generation)

Sandwich ELISA to quantify traces of crustacean in food;
Detection limit: 2 mg/kg crustacean

48 determinations
Incubation time: 30 min

R7312

10 Test strips
25 Test strips
Incubation time: 10 min

BL616-10
BL616-25

Lateral flow test strips
bioavid Lateral Flow Crustacean

Immunochromatographic tests for qualitative detection
of crustacean;
Detection limit: 10 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Crustaceans

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

100 reactions*

S3112

SureFood® ALLERGEN ID Fish

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

100 reactions*

S3110

SureFood® ALLERGEN ID Molluscs

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

100 reactions*

S3113

100 reactions*

S3105

100 reactions**

S3205

48 determinations
Incubation time: 30 min

R6102

100 reactions*

S3111

100 reactions**

S3211

48 determinations
Incubation time: 30 min

R6152

10 Test strips
25 Test strips
Incubation time: 10 min

BL603-10
BL603-25

100 reactions*

S3109

Various
Celery

Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Celery

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood® ALLERGEN QUANT Celery

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 1 mg/kg
depending on matrix and DNA preparation

Lupin

ELISA microtiter plates

RIDASCREEN®FAST Lupine

Sandwich ELISA to quantify traces of lupin in food
Detection limit: 0.7 mg/kg lupin protein
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Lupin

Detection limit: ≤ 0.4 mg/kg;
depending on matrix and DNA preparation
Real-time PCR – quantitative DNA detection

SureFood® ALLERGEN QUANT Lupin

Detection limit: ≤ 0.4 mg/kg
Quantification limit: 2.6 mg/kg
depending on matrix and DNA preparation

Mustard

ELISA microtiter plates

RIDASCREEN®FAST Senf/Mustard

Sandwich ELISA to quantify traces of mustard in food;
the assay detects yellow, white, brown and black mustard
Detection limit: 0.22 mg/kg mustard powder
Lateral flow test strips

bioavid Lateral Flow Senf/Mustard

Immunochromatographic tests for qualitative detection
of mustard;
Detection limit: 1 mg/kg depending on matrix
Real-time PCR – qualitative DNA detection

SureFood® ALLERGEN ID Mustard

Detection limit: ≤ 0.4 mg/kg
depending on matrix and DNA preparation

* Includes additional 100 reactions of Inhibition Control Mix (ICM).
** SureFood® QUANTARD Allergen 40 must be used for quantification.

52

Allergens
Real-time PCR – Multiplex
Product

Description

Multiplex Screening

Real-time PCR – qualitative DNA detection

No. of tests/amount Art. No.

SureFood® ALLERGEN ID 4plex
Peanut/Hazelnut/Walnut + IAC

Detection limit: ≤ 1 mg/kg;
depending on matrix and DNA preparation

100 reactions

S3402

SureFood® ALLERGEN ID 4plex
Soya/Celery/Mustard + IAC

Detection limit ≤ 0.4 mg/kg;
depending on matrix and DNA preparation

100 reactions

S3401

50 preparations

S1053

2 grams

S3301

Accessories
Real-time PCR

DNA preparation

SureFood® PREP Advanced

For highly processed matrices (food and feed)
Laboratory reference material for quantification

SureFood® QUANTARD Allergen 40

Corn flour contains 12 potential allergens in food
except sulphite and lactose with concentration of
40 mg/kg.
The material has been developed for PCR quantification of
allergens in food

Lateral Flow

Tests strips

bioavid
Wischtest Kit/Swabbing Kit

Swabbing kit with wood swabs for sampling of allergen
residues on surface (e.g. production lines) for bioavid lateral
flow kits

25 swabs, vials, pipettes,
10 ml buffer concentrate

BS800-25

bioavid
Wischtest Kit/Swabbing Kit (Plastic)

Swabbing kit with single packed plastic swabs for
sampling of allergen residues on surface
(e.g. production lines) for bioavid Test strips

26 swabs in two single
packaged plastic bags,
vials, pipettes,
10 ml buffer concentrate

BS801-25

bioavid
Absorptionspuffer/Absorbent Buffer

Buffer for preparation of polyphenol containing and strongly
colored samples (e.g. coffee, red wine) for bioavid lateral
flow kits

25 vials
(9 ml buffer each)

BS810-25

bioavid
Probenpuffer/Sample Buffer

The buffer is particularly suitable for preparation of difficult
samples (e.g. ketchup, mayonnaise, flour) for bioavid Test
strips

100 ml

BS815-100

Approx. 1 week
processing time

on request

Service by bioavid
Laboratory service

Service for the validation of difficult food matrices

53

R-Biopharm AG – Product catalogue 2017

GMO analysis in food and feed
Commercially available genetically modified organisms (GMO) are
usually transgenic plants in which DNA from foreign species were
artificially implemented.
These DNA sequences, mostly for herbicide
and/or insect resistance are enveloped in a
frame of viral or bacterial DNA sequences
which serves as promoters or terminators.
Different international and national
legislations and labelling regulations
require a multi-stage analysis, for which
real-time PCR is the method of choice.
In October 2015, the European Network of
GMO Laboratories (ENGL) defined
minimum performance requirements,
which are fulfilled by the SureFood® kits.
1. The presence of GMOs can be screened
by identifying the genetic sequence
elements 35S, NOS or FMV. Further
genetic elements may be expected in the
future. 35S positive results should be
confirmed for absence of natural
contamination with the cauliflower
mosaic virus using the CaMV detection
kit. Furthermore, the efficiency of the
DNA preparation should be confirmed
using plant DNA, when analysing a new
matrix.

54

2. For GMO positive samples the
identification of the GMO event is of
main interest, to classify the food
product as approved or illegal GMO. In
Europe the legislation EC 1829/2003 and
1830/2003 describes the relevant
regulations. Non-approved GMO
products are not allowed to enter or to
be produced or processed in Europe.
A zero tolerance strategy is in force for
Europe, while for feed samples a
technical threshold of 0.1 % has been
established (EC 618/2011). Food
products with a content of > 0.9 %
approved GMO per matrix must be
labelled.
3. For approved GMOs in food samples
quantification in the relevant range of
approximately 0.9 % is of main interest.
The GMO content in DNA copy numbers
can be quantified relative to the plant
matrix and the results will be given in
percent.

SureFood® PREP Basic/Advanced
• Efficient, streamlined DNA sample
preparation from food and feed matrices
• Highly purified DNA

SureFood® GMO SCREEN
• Multiplex assay for
35S/NOS/FMV + IAC,
BAR/NPTII/PAT/CTP2:CP4 EPSPS,
Corn/Soya/Canola/Cotton
• Single assays for vectors

SureFood® GMO QUANT
•
•
•
•

Identification and quantification
Robust detection system
Wide product range
Suitable for most available
real-time thermocyclers

55

R-Biopharm AG – Product catalogue 2017

GMO
DNA preparation
Product

Description

No. of tests/amount Art. No.

SureFood® PREP Basic

DNA preparation of food and feed

100 preparations

S1052

SureFood® PREP Advanced

DNA preparation of highly processed food and feed

50 preparations

S1053

SureFast® Animal+Plant Control

Extraction control for plant or animal matrix

100 reactions

F4053

SureFood® GMO Plant PLUS

Detection limit: 5 DNA copies depending on matrix and DNA
preparation

100 reactions

S2049

SureFood® GMO Plant

Complementary kit to S2026 and S2126
Detection limit: 5 DNA copies depending on matrix and
DNA preparation

100 reactions

S2056

SureFood® GMO SCREEN
CaMV

Detection limit: 5 DNA copies depending on matrix and DNA
preparation

100 reactions

S2027

SureFood® GMO SCREEN
P35S:BAR Rice

Detection limit: 0.01 % depending on matrix and DNA
preparation

2 x 50 reactions

S2022

SureFood® GMO SCREEN
35S + NOS + FMV

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions*

S2026

SureFood® GMO SCREEN 4plex
35S/NOS/FMV + IAC

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2126

SureFood® GMO Plant 4plex
Corn/Soya/Canola/Cotton

Detection limit: 4 ppm depending on matrix and DNA
preparation

100 reactions

S2156

SureFood® GMO Plant 4plex
Corn/Soya/Canola + IAC

Detection limit: 4 ppm depending on matrix and DNA
preparation

100 reactions

S2158

SureFood® GMO SCREEN 4plex
BAR/NPTII/PAT/CTP2:CP4 EPSPS

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2127

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2062

SureFood® GMO ID
MIR162 Corn

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2035

SureFood® GMO ID
MON863 Corn

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2037

SureFood® GMO ID
LibertyLink601 Rice

Detection limit: 0.01 % depending on matrix and DNA
preparation

2 x 50 reactions

S2023

SureFood® GMO ID
Bt63 Rice

Detection limit: 0.01 % depending on matrix and DNA
preparation

2 x 50 reactions

S2024

DNA preparation

Screening
Screening

Multiplex screening

Real-time PCR – qualitative DNA detection
Canola
SureFood® GMO ID
MS8 Canola
Corn

Rice

* Includes additional 100 reactions of Inhibition Control Mix (ICM); 100 reactions for each parameter.

56

GMO
Real-time PCR – qualitative DNA detection
Product

Description

No. of tests/amount Art. No.

SureFood® GMO ID
Roundup Ready Soya

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2030

SureFood® GMO ID
RR2Y Soya

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2034

SureFood® GMO ID
A2704-12 Soya

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2057

Detection limit: 0.01 % depending on matrix and DNA
preparation

100 reactions

S2161

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2061

SureFood® GMO QUANT
Bt176 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2015

SureFood® GMO QUANT
Bt11 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2016

SureFood® GMO QUANT
T25 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2017

SureFood® GMO QUANT
MON810 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2019

SureFood® GMO QUANT
35S Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2020

SureFood® GMO QUANT
NK603 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2050

SureFood® GMO QUANT
MON863 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2051

SureFood® GMO QUANT
MIR162 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2135

SureFood® GMO QUANT
GA21 Corn

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2054

SureFood® GMO QUANT
Roundup Ready Soya

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2014

SureFood® GMO QUANT
35S Soya

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2028

SureFood® GMO QUANT
RR2Y Soya

Limit of quantification: 0.1 % depending on matrix and
DNA preparation

2 x 50 reactions**

S2029

Soya

Multiplex real-time PCR
SureFood® GMO ID 4plex Soya I
MON87708, CV127, DP305423,
MON87701, MON87769

Real-time PCR – quantitative DNA detection
Canola
SureFood® GMO QUANT
GT73 Canola
Corn

Soya

** 1 x 50 reactions for the detection of the reference gene.

57

R-Biopharm AG – Product catalogue 2017

Identification of animal
species/risk material/BSE
Due to the increasing complexity of meat supply chains, and
prevalent product falsifications, species identification testing has
become a cornerstone of food quality assurance and fraud
prevention. Real-time PCR delivers robust, reliable results even from
processed food and feed samples.
Animal species detection
The aspects of animal species detection
might be categorized into three application
groups:
• Product falsification
Product falsification with cheaper
undeclared meat might be identified
qualitatively and quantitatively using the
ANIMAL ID and QUANT kits.
• Species detection
In some cases, especially for religious
aspects such as kosher or halal with a
zero tolerance strategy, highly sensitive
qualitative detection is required. The
ANIMAL ID Pork SENS PLUS kit enables an
extremely sensitive detection.
• Fish species detection
According to the EC 1379/2013
regulation fish products must be labelled
with the common trade name and the
scientific name. Fish ID real-time kits are
available for the most important fish
species.

58

• Feed
Due to the ending of the BSE crisis, it
might be expected that meat and bone
meal (MBM) will be used to feed animals
again. However, feeding to ruminants
should be avoided. Due to its stability,
DNA is an excellent marker for animal
identification. Real-time PCR can be used
even for processed food and feed
samples, with the exception of some
highly processed products such as
gelatin. The new product line with
Internal Amplification and Animal Control
(IAAC) has higher sensitivity and includes
an amplification and extraction control.

SureFood® PREP Basic

SureFood® ANIMAL ID

59

R-Biopharm AG – Product catalogue 2017

Animal species indentification/risk material/BSE
Real-time PCR – qualitative DNA detection
Product

Description

No. of tests/amount Art. No.

DNA preparation
SureFood® PREP Basic

DNA preparation of food and feed

100 preparations

S1052

SureFast® Animal+Plant Control

Extraction control for plant or animal matrix

100 reactions

F4053

SureFood® ANIMAL ID 4plex
Beef/Sheep/Goat + IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6121

SureFood® ANIMAL ID 4plex
Pork/Chicken/Turkey+IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6123

SureFood® ANIMAL ID
Beef IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6113

SureFood® ANIMAL ID
Horse IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6118

SureFood® ANIMAL ID
Horse & Donkey IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6119

SureFood® ANIMAL ID
Pork SENS PLUS

Detection limit: ≤ 0.0005% depending on matrix and DNA
preparation

100 reactions

S6017

SureFood® ANIMAL ID
Pork IAAC*

Detection limit: 0.5 % depending on matrix and DNA
preparation

100 reactions

S6114

SureFood® ANIMAL ID
Waterbuffalo IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6117

SureFood® ANIMAL ID
Chicken IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6115

SureFood® ANIMAL ID
Turkey IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6116

Detection limit: 0.5 % depending on matrix and DNA
preparation

100 reactions

S6112

Multiplex screening

Farm animals

Poultry

Other species
SureFood® ANIMAL ID
Cat & Dog IAAC*

* IAAC = Internal Amplification and Animal Control.
The IAAC kits require a 2-channel real-time thermocycler (FAM und VIC/HEX).
These kits have been validated on Bio-Rad CFX96, Qiagen Rotor-Gene, Roche LC480 and Agilent Mx3005P.
Exception: S6119 requires a 3-channel and S6121 a 4-channel device.

60

Animal species indentification/risk material/BSE
Real-time PCR – quantitative DNA detection
Product

Description

No. of tests/amount Art. No.

SureFood® ANIMAL ID
Rabbit IAAC*

Detection limit: 0.1 % depending on matrix and DNA
preparation

100 reactions

S6120

SureFood® ANIMAL QUANT Beef

Detection limit: 0.04 % depending on matrix and DNA
preparation

2 x 50 reactions**

S1010

SureFood® ANIMAL QUANT Equus

Detection of horse, donkey and zebra
Detection limit: 0.1 % depending on matrix and DNA
preparation

2 x 50 reactions**

S1016

SureFood® ANIMAL QUANT Sheep

Detection limit: 0.1 % depending on matrix and DNA
preparation

2 x 50 Reaktionen**

S1017

SureFood® ANIMAL QUANT Pork

Detection limit: 0.04 % depending on matrix and DNA
preparation

2 x 50 reactions**

S1011

Farm animals

Poultry

** 1 x 50 reactions for the detection of the reference gene.

61

R-Biopharm AG – Product catalogue 2017

Animal species indentification/risk material/BSE
SureFood® FISH ID
Product

Description

No. of tests/amount Art. No.

SureFood® ANIMAL QUANT Chicken

Detection limit: 0.1 % depending on matrix and DNA
preparation

2 x 50 reactions**

S1014

SureFood® FISH ID
3plex Halibut IAAC*

Differentiation of white (Hippoglossus hippoglossus) and
black halibut (Reinhardtius hippoglossoides);
Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6201

SureFood® FISH ID
Oncorhynchus tshawytscha IAAC*

Detection of chinook salmon; Detection limit: 2 %
depending on matrix and DNA preparation

50 reactions

S6301

SureFood® FISH ID
Oncorhynchus mykiss IAAC*

Detection of rainbow trout; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6302

SureFood® FISH ID
Oncorhynchus gorbuscha IAAC*

Detection of humpback salmon; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6303

SureFood® FISH ID
Oncorhynchus nerka IAAC*

Detection of red salmon; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6304

SureFood® FISH ID
Salmo trutta IAAC*

Detection of trout; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6305

SureFood® FISH ID
Salmo salar IAAC*

Detection of atlantic salmon; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6306

SureFood® FISH ID
Gadus macrocephalus IAAC*

Detection of pacific cod; Detection limit: 2 %
depending on matrix and DNA preparation

50 reactions

S6308

SureFood® FISH ID
Gadus morhua IAAC*

Detection of atlantic cod; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6310

SureFood® FISH ID
Pollachius virens IAAC*

Detection of pollock/saithe; Detection limit: 2 %
depending on matrix and DNA preparation

50 reactions

S6309

SureFood® FISH ID
Merlangius merlangus IAAC*

Detection of whiting; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6312

SureFood® FISH ID
Gadus chalcogrammus IAAC*

Detection of Alaska pollock; Detection limit: 5 %
depending on matrix and DNA preparation

50 reactions

S6313

SureFood® FISH ID
Merluccius merluccius IAAC*

Detection of european hake; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6311

Fish

* IAAC = Internal Amplification and Animal Control.
The IAAC kits require a 2-channel real-time thermocycler (FAM und VIC/HEX).
These kits have been validated on Bio-Rad CFX96, Qiagen Rotor-Gene, Roche LC480 and Agilent Mx3005P.
Exception: S6119 requires a 3-channel and S6121 a 4-channel device.

62

Animal species indentification/risk material/BSE
Risk material
Product

Description

No. of tests/amount Art. No.

SureFood® FISH ID
Melanogrammus aeglefinus IAAC*

Detection of haddock; Detection limit: 1 %
depending on matrix and DNA preparation

50 reactions

S6307

Enzyme immunoassay for quantitative analysis of
risk material (CNS) in processed meat and meat products
Detection limit: < 0.2 % for CNS tissue

96 determinations
Incubation time: 1 hr

R6701

Enzyme immunoassay for qualitative analysis of risk material
(CNS) in raw meat, meat products and on contaminated
surfaces
Detection limit: < 0.1 % for CNS tissue

96 determinations
Incubation time: 15 min

R6703

ELISA microtiter plates
RIDASCREEN® Risk Material

BSE
RIDASCREEN® Risk Material 10/5

BSE/antibody
RIDA® mAb L42

Monoclonal antibody for the detection of prion-protein with
immunohistochemistry (IHC) and immunoblot

23 µg

R8005

RIDA® mAb P4

Monoclonal antibody for the detection of prion-protein with
immunohistochemistry (IHC) and immunoblot

1 mg

R8007

RIDA® mAb P4

Monoclonal antibody for the detection of prion-protein with
immunohistochemistry (IHC) and immunoblot

0.1 mg

R8008

63

R-Biopharm AG – Product catalogue 2017

Analysis for microbiological
food safety
Rapid test formats for reliable microbiological analysis in food and plants for
highly specific, sensitive and fast test combinations for use with a wide
range of applications.
Product testing
All kinds of commodities are potentially at
risk of contamination by spoiling organisms
and pathogens. Therefore, R-Biopharm
offers reliable kits for the analysis of meat
and meat-products, dairy products, egg
and egg-products, vegetable, fruits, herbs
and spices, beverages, cereals and cerealproducts as well as prepared meals.
Well-established methods for on-site testing
are classic microbiological testing, highly
specific detection with real-time PCR, or
confirmation of bacterial toxins by
ELISA-tests.

64

Production surrounding area and
condition
Quality and safety standards are considered
when minimizing the risk of product
contamination.
Important characteristics for tests used in
efficient hygiene and cleaning control are:
• High sensitivity
• Rapidness
• Repeatability
Reliability of results is important for
immediate and long-term decisions.

Bacterial toxins and pathogens
RIDASCREEN® ELISA
• Detection of bacterial toxins
• Detection of pathogens

Compact Dry
Dry nutrient media for detection of
pathogens

SureFast® realt-time PCR
• Real-time PCR for screening und species
identification
• Effective DNA/RNA-extraction
• Multiplex real-time kits

Bacteria, viruses, contaminants
and spoilers
SureFast® real-time PCR
• For screening und species identification
• Effective DNA/RNA-extraction
• Multiplex real-time kits

Compact Dry
Dry nutrient media for enumeration
of microorganisms

Hygiene & cleaning

Compact Dry with wet swab
systems, RIDA®STAMP
Nutrient media for detection of
microorganisms

Lumitester PD-30 with LuciPac Pen
• Sensitive AMP/ATP detection
• Automatic alinement of measured data
• Software based evaluation

RIDA®CHECK
• Detection of protein residues
• Colorimetric test for rapid cleaning control

65

R-Biopharm AG – Product catalogue 2017

Microbiology/hygiene
Culture medium systems for colony counting and pathogen detection
in food or surface samples
Product

Description

Compact Dry

Nutrient pads

No. of tests/amount Art. No.

Compact Dry AQ

Test plate with nutrient pad for quantitative detection of
heterotrophic water bacteria

100 determinations
40 determinations

HS9541
HS9542

Compact Dry CC

Test plate with nutrient pad for detection of total aerobic
count in teaproducts

100 determinations
40 determinations

HS7311
HS7312

Compact Dry CF
MicroVal MV0806-003L;
NordVal 35;
AOAC-RI 110401

Test plate with nutrient pad for quantitative detection of
coliforms

100 determinations
40 determinations

HS8791
HS8792

Compact Dry EC
MicroVal MV0806-004LR;
NordVal 36;
AOAC-RI 110402

Test plate with nutrient pad for quantitative detection of
E. coli and coliforms

100 determinations
40 determinations

HS8781
HS8782

Compact Dry ETB
MicroVal MV0806-002LR;
NordVal 34

Test plate with nutrient pad for quantitative detection of
Enterobacteriaceae

100 determinations
40 determinations

HS9431
HS9432

Compact Dry ETC
NordVal 47

Test plate with nutrient pad for quantitative detection of
Enterococci

100 determinations
40 determinations

HS9461
HS9462

Compact Dry LS

Test plate with nutrient pad for quantitative detection of
Listeria spp.

100 determinations
40 determinations

HS8811
HS8812

Compact Dry PA

Test plate with nutrient pad for quantitative detection of
Pseudomonas aeruginosa

100 determinations
40 determinations

HS9491
HS9492

Compact Dry SL

Test plate with nutrient pad for detection of Salmonella

100 determinations
40 determinations

HS9401
HS9402

Compact Dry TC
MicroVal RQA2007LR01;
NordVal 33;
AOAC-RI 10404

Test plate with nutrient pad for detection of total aerobic
count

100 determinations
40 determinations

HS8771
HS8772

Compact Dry VP

Test plate with nutrient pad for quantitative detection of
Vibrio parahaemolyticus and Vibrio spp.

100 determinations
40 determinations

HS8821
HS8822

Compact Dry YM
MicroVal RQA2008LR10;
NordVal 43;
AOAC-RI 100401

Test plate with nutrient pad for quantitative detection of
yeast and mold

100 determinations
40 determinations

HS8801
HS8802

Compact Dry YMR
(Approvals in progress)

Test plate with nutrient pad for rapid quantitative detection
of yeast and mold in 48 - 72 h

100 determinations
40 determinations

HS9801
HS9802

Compact Dry X-BC
MicroVal 2011LR41;
NordVal 45

Test plate with nutrient pad for quantitative detection of
Bacillus cereus

100 determinations
40 determinations

HS9721
HS9722

Compact Dry X-SA
MicroVal 2008LR14;
NordVal 42;
AOAC-RI 81001

Test plate with nutrient pad for quantitative detection of
Staphylococcus aureus

100 determinations
40 determinations

HS9621
HS9622

Accessories
RIDA® 0.9 % NaCl, sterile

1 ml sterile sodium chloride solution

150 pieces (1 ml each)

Z0301

Promedia ST-25

Sampling device
(sterile swab in 10 ml sterile PBS buffer)

10 pieces

Z0302

Compact Dry Swab

Sampling set (sterile swabs in 1 ml PBS/peptone buffer)

40 pieces

ZCS1002953

Dilution Rack-PBS

Dilution set for preparation of 10-fold dilution series
(9 ml PBS buffer per well) - sterile

128 pieces

ZDP1000888

Dilution Rack-MRD

Dilution set for preparation of 10-fold dilution series
(9 ml MRD buffer per well) - sterile

128 pieces

ZDM1000889

Opener for Dilution Rack

For sterile opening of Dilution Rack

1 piece

ZOP1000887

Frame - 100 cm

Frame for definition of 100 cm for swab sampling

5 pieces

ZFR1600000

2

66

2

Microbiology/hygiene
Culture medium systems for surface specimen/hygiene monitoring
Product

Description

No. of tests/amount Art. No.

RIDA®STAMP Coliform

Agar stamp plate for surface monitoring of Coliforms on
solid foods and environmental surfaces

50 determinations
25 determinations

HS0411
HS0412

RIDA®STAMP ECC

Agar stamp plate for surface monitoring of
E. coli & Coliforms on solid foods and environmental
surfaces

50 determinations
25 determinations

HS0431
HS0432

RIDA®STAMP Pseudomonas

Agar stamp plate for surface monitoring of
Pseudomonas spp. on solid foods and environmental
surfaces

50 determinations
25 determinations

HS2011
HS2012

RIDA®STAMP Salmonella

Agar stamp plate for surface monitoring of Salmonella on
solid foods and environmental surfaces

25 determinations

HS0392

RIDA®STAMP S. aureus

Agar stamp plate for surface monitoring of
Staphylococcus aureus on solid foods and environmental
surfaces

25 determinations

HS0462

RIDA®STAMP Total

Agar stamp plate for surface monitoring of total count on
solid foods and environmental surfaces

50 determinations
25 determinations

HS0291
HS0292

RIDA®STAMP Total Desi

Agar stamp plate for surface monitoring of total count in
case of presence of desinfectants on solid foods and
environmental surfaces

50 determinations
25 determinations

HS1831
HS1832

RIDA®STAMP YM-P

Agar stamp plate for surface monitoring of fungi on solid
foods and environmental surfaces

50 determinations
25 determinations

HS0371
HS0372

67

R-Biopharm AG – Product catalogue 2017

Microbiology/hygiene
Pathogens & bacterial toxins
Product

Description

No. of tests/amount Art. No.

DNA preparation
SureFast® PREP Bacteria

Preparation of bacteria DNA

100 preparations

F1021

SureFast® Speed PREP

Preparation of bacteria- and parasites-DNA from enrichment
cultures and tissue samples

100 preparations

F1054

Bacillus cereus

Qualitative real-time PCR

SureFast® Bacillus cereus group PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5126

SureFast® Emetic Bacillus cereus PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5127

Campylobacter

ELISA microtiter plates

RIDASCREEN® Campylobacter

Enzyme immunoassay for the determination of
Campylobacter in food

48 determinations

R4204

100 reactions

F5112

Qualitative real-time PCR
SureFast® Campylobacter PLUS
(C. jejuni, C. lari, C. coli)

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

Clostridium

Qualitative real-time PCR

SureFast® Clostridium botulinum
Screening PLUS

Qualitative DNA detection
Detection of C. botulinum toxin groups A, B, E, F
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5110

SureFast® Clostridium perfringens
PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5123

Cronobacter

Qualitative real-time PCR

SureFast® Cronobacter PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5114

SureFast® Cronobacter sakazakii PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5115

E.coli

ELISA microtiter plates

RIDASCREEN® Verotoxin

Enzyme immunoassay for the detection of pathogenic
E. coli (indirectly via verotoxins 1 and 2)

96 determinations
Incubation time: 1 hr 45 min

R5701

100 tubes
25 tubes

Z1000
Z1003

Accessories
Enrichment broth

mTSB-bouillon with Mytomycin C for the enrichment of
verotoxin (shigatoxin)-producing E. coli bacteria
Qualitative real-time PCR

SureFast® Escherichia coli PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5157

SureFast® Escherichia coli eae gene

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5104

SureFast® EHEC/EPEC 4plex

Qualitative DNA detection of virulence gene stx1, stx2, eae,
ipaH (E. coli/Shigella differenciation)

100 reactions

F5128

SureFast® STEC Screening PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5105

Listeria

ELISA microtiter plates

RIDASCREEN® Listeria

Enzyme immunoassay for the determination of
Listeria in food

96 determinations

R4202

Qualitative real-time PCR
SureFast® Listeria Screening
PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5117

SureFast® Listeria monocytogenes
PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5113

68

Microbiology/hygiene
Pathogens & bacterial toxins
Product

Description

Pseudomonas

Qualitative real-time PCR

SureFast®
Pseudomonas aeruginosa PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies,

Salmonella

ELISA

RIDASCREEN® Salmonella
AFNOR RBP 31/01-06/08

Enzyme immunoassay for the determination of
Salmonella in food, feed and environmental samples

No. of tests/amount Art. No.
100 reactions

F5503

96 determinations

R4201

100 preparations

F1007

100 reactions

F5111

DNA preparation
SureFast® PREP Salmonella
AOAC-RI 041103

DNA preparation of Salmonella
Qualitative real-time PCR

SureFast® Salmonella PLUS
AOAC-RI 041103

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment
Qualitative real-time PCR and DNA preparation

SureFast® Salmonella ONE

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment
Kit includes DNA preparation

100 reactions /
100 preparations

F5211

SureFast® Salmonella Serotype 3plex

Qualitative DNA detection of S. typhimurium and
S. enteritidis
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5159

Staphylococcus

ELISA microtiter plates

RIDASCREEN® SET A, B, C, D, E

Enzyme immunoassay for identification of
staphylococcus enterotoxins A, B, C, D and E in food
and bacterial cultures
Detection limit: 0.25 ng/ml toxin (0.375 ng/g)

12 determinations
Incubation time: 2 hrs 45 min

R4101

RIDASCREEN® SET Total

Enzyme immunoassay for combined detection of
staphylococcus enterotoxins (A - E) in food and bacterial
cultures
Detection limit: 0.25 ng/ml toxin (0.375 ng/g)

96 determinations
48 determinations
Incubation time: 2 hrs 45 min

R4105
R4106

100 reactions

F5116

Qualitative real-time PCR
SureFast® Staphylococcus aureus
PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

Vibrio

Qualitative real-time PCR

SureFast® Vibrio Screening
PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5118

SureFast® Vibrio 4 plex
(V. cholerae, V. parahaemolyticus,
V. vulnificus +IAC)

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies, 1 cfu after enrichment

100 reactions

F5161

Yersinia

Qualitative real-time PCR

SureFast® Yersinia enterocolitica
PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies

100 reactions

F5124

Histomonas (parasites)

Qualitative real-time PCR

SureFast® Histomonas meleagridis
PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies

100 reactions

F5158

100 reactions /
100 preparations

F5213

Qualitative real-time PCR and DNA preparation
SureFast® Histomonas meleagridis
ONE

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies,
Kit includes a solution for DNA-extraction

69

R-Biopharm AG – Product catalogue 2017

Microbiology/hygiene
Viruses
Product

Description

No. of tests/amount Art. No.

DNA/RNA preparation
SureFast® PREP DNA/RNA Virus

DNA/RNA preparation of viruses

100 preparations

F1051

real-time reverse transcriptase PCR (qualitative detection)
SureFast® Norovirus PLUS

Qualitative detection of Norovirus genogroup I and II
Detection limit: ≤ 50 RNA copies

100 reactions

F7001

SureFast® Norovirus I & II
3plex

Qualitative detection and differentiation of Norovirus
genotype I and II
Detection limit: ≤ 50 RNA copies

100 reactions

F7140

SureFast® Norovirus/Hepatitis A
3plex

Qualitative detection of Norovirus and Hepatitis A
Detection limit: ≤ 50 RNA copies

100 reactions

F7124

SureFast® Hepatitis A PLUS

Qualitative detection of Hepatitis A
Detection limit: ≤ 50 RNA copies

100 reactions

F7125

SureFast®Influenza A PLUS

Qualitative detection of influenza virus A
Detection limit: ≤ 25 RNA copies

100 reactions

F7103

SureFast®Influenza A H5/H7/H9
4plex

Qualitative detection and differentiation of influenza virus
A, H5, H7 and H9
Detection limit: ≤ 25 RNA copies

100 reactions

F7139

100 preparations

F1023

Water analysis
DNA preparation
SureFast® PREP Aqua

DNA preparation of bacterial cells from water samples

Legionella

Qualitative real-time PCR

SureFast® Legionella Screen PLUS

Qualitative DNA detection of Legionella spp.

100 reactions

F5502

SureFast® Legionella pneumophila
PLUS

Qualitative DNA detection of Legionella pneumophila

100 reactions

F5501

SureFast® Legionella 3plex

Qualitative DNA detection of Legionella spp. and Legionella
pneumophila
Detection limit: ≤ 5 DNA copies

100 reactions

F5505

Qualitative real-time PCR
SureFast® Parasitic Water Panel 4plex

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies

100 reactions

F5506

SureFast® Enterobacteriaceae
Screening PLUS

Qualitative DNA detection
Detection limit: ≤ 5 DNA copies

100 reactions

F5507

SureFast® Pseudomonas aeruginosa
PLUS

Qualitative DNA detection of Pseudomonas aeruginosa,
Detection limit: ≤ 5 DNA copies

100 reactions

F5503

AMP/ATP detection

Bioluminescence

LuciPac® Pen AQUA

Test system for hygiene control in liquid samples (based on
detection of ATP/AMP)
Reaction tubes with integrated sample stick for use with
Lumitester PD-30

100 reactions

ZLA1002672

20 reactions

ZLPP1002673

Accessories
RIDA® Clean Extract

Sample preparation kit for lubricants and paints to be used
together with LuciPac® Pen AQUA

* Find more products for microbiological water analysis on page 66 under “Culture Medium Systems for Colony Counting and Pathogen Detection”.

70

Microbiology/hygiene
Beverage analysis
Product

Description

Juice

DNA preparation

GEN-IAL® Simplex® Easy Spin DNA kit

Alicyclobacillus DNA extraction from fruit or vegetable juices
or concentrates

No. of tests/amount Art. No.
50 preparations

SES 0050

DNA Screening of Alicyclobacillus ssp., A. acidocaldarius
and A. acidoterrestris in fruit juices or concentrates

50 reactions

TPABM 0050

GEN-IAL® Alicyclobacillus spp.

Specific DNA detection of Alicyclobacillus

50 reactions

TPAB 0050

Wine

DNA preparation
100 preparations

SEW 0100

Qualitative multiplex real-time PCR
GEN-IAL® Alicyclobacillus multiplex
TaqMan™

GEN-IAL® Simplex® Easy Wine kit

DNA preparation of wine samples
Qualitative multiplex real-time PCR

GEN-IAL® First-Wine PCR Screening
TaqMan™

DNA screening and differentiation of
wine spoilage bacteria and yeasts: Lactobacillus; Pediococcus;
Oenococcus oeni; acetic acid bacteria; yeast

50 reactions

TPWS 0050

GEN-IAL® First-Wine PCR Screening
TaqMan™

DNA Screening of wine spoilage bacteria:
Lactobacillus; Pediococcus; Oenococcus oeni;
acetic acid bacteria

50 reactions

TPWSOH 0050

Qualitative real-time PCR
GEN-IAL® First-Oenococcus Oeni

Specific DNA detection of Oenococcus oeni

50 reactions

TPOE 0050

GEN-IAL® First-Wine Screening
Biogene Amine

Specific DNA detection of bacteria forming biogenic amines

50 reactions

BAM 0050

Wine/beer

Qualitative real-time PCR

GEN-IAL® Acetic acid bacteria
TaqMan™

Specific DNA detection of acetic acid bacteria

50 reactions

TPA 0050

GEN-IAL® QuickGEN*
Acetic acid bacteria TaqMan™

Specific DNA detection of acetic acid bacteria

50 reactions

QTPA 0050

GEN-IAL® Dekkera bruxellensis
TaqMan™ FH

Specific DNA detection of Dekkera bruxellensis
(FAM HEX)

50 reactions

TPYDB 0050 FH

GEN-IAL® Dekkera bruxellensis
TaqMan™ FR

Specific DNA detection of Dekkera bruxellensis
(FAM ROX)

50 reactions

TPYDB 0050 FR

GEN-IAL® Dekkera bruxellensis
TaqMan™ Spartan DX-12

Specific DNA detection of Dekkera bruxellensis

50 reactions

TPYDB 0050 SP

GEN-IAL® Dekkera bruxellensis
TaqMan™ MyGo Pro

Specific DNA detection of Dekkera bruxellensis

50 reactions

QTPYDB 0050
MG

* QuickGEN kits deliver a rapid, easy one-step DNA lysis and amplification method. Pre-enriched samples as well as centrifuged or filtrated samples
may be used with CSE 0100 or FSE 0100 and subsequent QuickGEN detection kits.

71

R-Biopharm AG – Product catalogue 2017

Microbiology/hygiene
Beverage analysis
Product

Description

Beer

DNA preparation

No. of tests/amount Art. No.

GEN-IAL® Simplex® Easy DNA kit

DNA preparation of beverage samples

100 preparations

SE 0100

GEN-IAL® QuickGEN*
Sample preparation filtration

DNA preparation of beverage samples, Filtration

100 preparations

FSE 0100

100 preparations

CSE 0100

DNA preparation with centrifugation without enrichment
GEN-IAL® QuickGEN*
Sample preparation centrifugation

DNA preparation of beverage samples, Centrifugation

Beer – bacteria & yeast

Qualitative multiplex real-time PCR

GEN-IAL®
First-Beer Differentiation PCR Kit

Multiplex detection (30 species) and identification
(19 species) of relevant beer spoilers

96 reactions

TPBD 0096

GEN-IAL®
First-Beer Differentiation PCR Kit
for LC 480

Multiplex detection (30 species) and identification
(19 species) of relevant beer spoilers for LC480

96 reactions

TPBD 0096
LC480

GEN-IAL® QuickGEN*
First-Beer Differentiation PCR Kit

Multiplex detection (30 species) and identification
(19 species) of relevant beer spoilers

96 reactions

QTPBD 0096

GEN-IAL® QuickGEN*
First-Beer Differentiation PCR Kit
for LC 480

Multiplex detection (30 species) and identification
(19 species) of relevant beer spoilers for LC480

96 reactions

QTPBD 0096
LC480

GEN-IAL® QuickGEN*
First-Beer Differentiation PCR Kit
for MyGo Pro

Multiplex detection (30 species) and identification
(19 species) of relevant beer spoilers for MyGo Pro

96 reactions

QTPBD 0096
MG

GEN-IAL®
First-Beer yeast and bacteria
differentiation TaqMan™

Multiplex detection and identification of beverage spoiling
bacteria and yeasts

96 reactions

TPYB 0096

GEN-IAL®
First-Beer yeast and bacteria
differentiation TaqMan™ LC 480

Multiplex detection and identification of beverage spoiling
bacteria and yeasts

96 reactions

TPYB 0096
LC480

GEN-IAL® QuickGEN*
First-Beer yeast and bacteria
differentiation TaqMan™ MyGo Pro

Multiplex detection and identification of beverage spoiling
bacteria and yeasts for MyGo Pro

96 reactions

QTPYB 0096
MG

GEN-IAL® P1 Hyb Probe Screening
LC 2.0 FRET

DNA screening and differentiation of bacteria and yeasts for
LC 2.0

50 reactions

PP1H 0050
LC2.0

GEN-IAL® P1 Screening
TaqMan™

DNA Screening and differentiation of beer spoiling bacteria
and yeasts

50 reactions

PP1T 0050

GEN-IAL® QuickGEN*
P1 Screening TaqMan™

DNA screening and differentiation of beer spoiling bacteria
and yeasts

50 reactions

QPP1T 0050

GEN-IAL® QuickGEN*
P1 Screening TaqMan™

DNA screening and differentiation of beer spoiling bacteria
and hop resistance genes

50 reactions

QPP1HR 0050

GEN-IAL® P1 Screening
Spartan DX-12 TaqMan™

DNA screening without differentiation
of bacteria and yeasts

50 reactions

PP1T 0050 SP

GEN-IAL® P1OHScreening
Spartan DX-12 TaqMan™

DNA screening without differentiation of bacteria

50 reactions

PP1TOH 0050
SP

GEN-IAL® QuickGEN*
First-Biofilm TaqMan™

Specific DNA detection of Lactococcus lactis,
Leuconostoc mesenteroides and Pichia anomala

50 reactions

QTPBF 0050

GEN-IAL®
First Yeast Hyb Probe Screening
LC 2.0 FRET

DNA screening and differentiation of yeasts

50 reactions

PYHYB 0050
LC2.0

* QuickGEN kits deliver a rapid, easy one-step DNA lysis and amplification method. Pre-enriched samples as well as centrifuged or filtrated samples
may be used with CSE 0100 or FSE 0100 and subsequent QuickGEN detection kits.

72

Microbiology/hygiene
Beverage analysis
Product

Description

Beer – bacteria

Qualitative real-time PCR

GEN-IAL®
Pectinatus spp./Megasphaera spp.
TaqMan™

Specific DNA detection and differentiation of Pectinatus and
Megasphaera

Beer – resistance genes

Qualitative real-time PCR

GEN-IAL® hop resistance genes
horA and horC / hitA and orf5
TaqMan™

No. of tests/amount Art. No.
50 reactions

TPPMD

Specific DNA detection of hop resistance genes

50 reactions

TPHR 0050

GEN-IAL® QuickGEN* hop resistance
genes horA and horC / hitA and orf5
TaqMan™

Specific DNA detection of hop resistance genes

50 reactions

QTPHR 0050

Beer – yeast

Qualitative real-time PCR

GEN-IAL® Dekkera anomala
TaqMan™

Specific DNA detection of Dekkera anomala

50 reactions

TPYDA 0050

GEN-IAL® Pichia anomala
TaqMan™

Specific DNA detection of Pichia anomala

50 reactions

TPYPA 0050

GEN-IAL® Saccharomyces diastaticus
TaqMan™

Specific DNA detection of Saccharomyces diastaticus

50 reactions

TPYSD 0050

GEN-IAL® Pichia membranaefaciens
TaqMan™

Specific DNA detection of Pichia membranaefaciens

50 reactions

TPYPM 0050

GEN-IAL® Bottom fermented yeast
TaqMan™

Specific DNA detection of bottom fermented yeast

50 reactions

TPYUG 0050

GEN-IAL® Top fermented yeast
TaqMan™

Specific DNA detection of top fermented yeast

50 reactions

TPYOG 0050

GEN-IAL® accessories

real-time PCR

GEN-IAL® Dekkera bruxellensis
Standards

DNA standards for Dekkera bruxellensis quantification

200.000 cfu

DBST 0100

Color Compensation Kit
LC 480

Color compensation kit for multiplex assays

5 reactions

PP1TCC 0005

Color Compensation Kit
LC LightCycler

Color compensation kit for multiplex assays

5 reactions

CCFH 0005

Washing solution

Washing solution for SEW 0100

43 ml

WS 0100

100 determinations

ZLP1002667

100 determinations
40 determinations

R1091
R1092

Test systems for cleaning control
AMP/ATP detection

Bioluminescence

LuciPac® Pen

Test system for hygiene control on surfaces
(based on detection of ATP/AMP)
Reaction tubes with integrated swab for use with
Lumitester PD-30

Protein tests

Swab tests

RIDA®CHECK

Colorimetric test, ready-to-use swabs for the detection of
protein residues on surfaces

* QuickGEN kits deliver a rapid, easy one-step DNA lysis and amplification method. Pre-enriched samples as well as centrifuged or filtrated samples
may be used with CSE 0100 or FSE 0100 and subsequent QuickGEN detection kits.

73

R-Biopharm AG – Product catalogue 2017

Equipment and accessories
In laboratories equipment and machines are now routinely used to
standardise analysis. Each analysis has specific needs and
requirements which necessitates different accessories. This is where
the team of technicians from R-Biopharm comes in.
What is the right equipment required
for each test?
We develop matching applications for an
even easier, faster and more efficient
performance and analysis. Whether an
automated processing of an ELISA by a fully
automated analyser, or a portable analyser
for lateral flow test.
With the RIDA®SMART APP the quantitative
evaluation of rapid tests is possible for the
demand on-site. Our specialists improve
and update these systems and devices
continuously. That’s how we can offer you
the best support with state of the art
technologies for your laboratory or on-site
testing.

74

The range of equipment and software
covers the full portfolio and requirements
of R-Biopharm products.
The requirements for a high or low sample
throughput in the laboratory will be
observed: starting from optimal sample
preparation, performance of test
procedures, through analysing and
evaluation for manually or fully automated
applications for all products, their specific
needs are considered.
Everything for your analysis and
performance just from one supplier.

RIDA®SMART APP
Test evaluation
Smartphone application for the analysis of
lateral flow tests

ThunderBolt®
Test running
Automate for the processing of an ELISA

RIDA®CUBE SCAN
Single tests
Small automate for enzymatic tests

75

R-Biopharm AG – Product catalogue 2017

Equipment/software/accessories
Equipment
Product

Description

ELISA

Photometer

ChroMate® 4300

Microtiter plate reader;
suitable only for 450nm wavelenght with reference
wavelenght at 630nm

1

ZCR4300

Microtiter plate photometer

1

ZELX800

BioTek® ELx800™

No. of tests/amount Art. No.

Automates
ChemWell®2910

1-microtiter plate analyser

1

ZCW2910

GEMINI

2-microtiter plate analyser

1

ZGEMINI

ThunderBolt®

2-microtiter plate analyser

1

ZTB

Bolt™

1-microtiter plate analyser

1

ZBOLT

Mycotoxin analysis

HPLC automate

RIDA®CREST

Online handling system to be used in conjunction with
IMMUNOPREP® ONLINE cartridges

1

ZRIDACREST
2000

RIDA®CREST ICE

Automated cartridge exchange and high presure dispenser
units to be used in conjunction with the
IMMUNOPREP® ONLINE cartridges

1

ZRIDACREST
1500

Enzymatic analysis

Autoanalyzer

RIDA®CUBE SCAN 340/505
Analyser set

Automatic analyser only for RIDA®CUBE test kits

1 set

ZRCS0505

RIDA®CUBE SCAN 340/546
Analyser set

Automatic analyser only for RIDA®CUBE test kits

1 set

ZRCS0546

RIDA®CUBE SCAN 340/580
Analyser set

Automatic analyser only for RIDA®CUBE test kits

1 set

ZRCS0580

RIDA®CUBE SCAN
Tablet PC

Separate tablet for replacement

1

ZRCT0500

qPCR

qPCR thermocycler
1 unit

ZMX3005P1

Mx3005P

real-time PCR instrument with notebook computer

Mycotoxin rapid test

RIDA®QUICK

RIDA®SMART APP STAND NEXUS 6

Smartphone stand for NEXUS 6

1

ZRSAN6STAND

RIDA®SMART APP STAND NEXUS 6P

Smartphone stand for NEXUS 6P

1

ZRSAN6PSTAND

76

Equipment/software/accessories
Equipment
Product

Description

No. of tests/amount Art. No.

CULTURA® Mini Incubator

Incubator for incubations at 30 - 45 °C
(Compact Dry, RIDA®STAMP, Pathogen ELISAs,
microbiological MTP-format Vitamin analysis etc.)

1

ZC7140651

Lumitester PD-30

Luminometer for AMP/ATP measurement with
LuciPac® Pen

1

ZLT-1402653

Lumitester PD-20/PD-30 Control Kit

Positive control lamp with charger and negative control
tubes for functional testing of Lumitester PD-20 and
Lumitester PD-30 devices

1

ZLC1002657

R-Biopharm FP 50

Pipette 50 μl

1 unit

Z0006

R-Biopharm FP 100

Pipette 100 μl

1 unit

Z0007

R-Biopharm FP 1000

Pipette 1000 μl

1 unit

Z0008

R-Biopharm FP 150

Pipette 150 μl

1 unit

Z0009

Microbiology

Pipettes

Pipettes for RIDA®QUICK mycotoxin analysis
PE-Pipettes

1 ml pipette for RIDA®QUICK tests

100

Z0005

PP-Test Tubes

50 ml test tubes for RIDA®QUICK tests

25

Z210261

RIDA®SOFT Win.NET

Software for measurement, evaluation and documentation
of RIDASCREEN® ELISAs

1 unit

Z9996

Mycotoxines lateral flow tests

RIDA®QUICK

RIDA®SMART APP

Software application for the NEXUS 6 and NEXUS 6P
smartphone for the quantification of RIDA®QUICK RQS
mycotoxin lateral flow tests.

1 voucher

ZRSAM1000

Software
ELISA

77

R-Biopharm AG – Product catalogue 2017

Equipment/software/accessories
Accessories
Product

Description

Mycotoxin analysis (HPLC)

Immunoaffinity columns

No. of tests/amount Art. No.

PBS-Tablets

Phosphate buffered saline tablets

100 (suitable for 10 l)

RBRRP202

Immunoaffinity Column Rack

Durable brass and PFTE rack allowing 6 samples to be
processed at one time using Immunoaffinity columns

1 unit

RBRCR1

Immunoaffinity Column
Accessory Pack

Glass barrels, syringes and adapters for use
with all formats of RBR Immunoaffinity columns

10 each

RBRAP01

Adapter

Re-usable adapters for use with Immunoaffinity columns

10 units

RBRRP200

Glass syringe barrels

for use with Immunoaffinity columns

1 unit

RBRRP201

Syringe pump unit

Re-usable syringe and rubber connector for use with
Immunoaffinity columns

1 each

RBRRP203

Aflatoxin analysis
KOBRA® CELL

Electrochemical cell for derivatisation of aflatoxins
B1 and G1 using HPLC

1 unit

RBRK01

KOBRA® CELL Membrane

Replacement membrane for the KOBRA® CELL

1 unit

RBRK02

KOBRA® CELL Installation Pack

Contains 5 metres of PEEK tubing, a tubing cutter,
10 ferrules and 3 unions

1 unit

RBRK03

Stainless steel electrode

Replacement stainless steel electrode for KOBRA® CELL

1 unit

RBRK04

Platinum working electrode

Replacement working electrode for KOBRA® CELL

1 unit

RBRK05

Power Pack

Replacement power pack for KOBRA® CELL

1 unit

RBRK06

Spacer

Replacement spacer 0.2 mm for KOBRA® CELL
Replacement spacer 0.1 mm for KOBRA® CELL
Replacement spacer 0.1 mm for KOBRA® CELL
with reaction channel

1 unit

RBRK07
RBRK08
RBRK09

Spacer grid

Replacement spacer grid for KOBRA® CELL

1 unit

RBRK10

Premi®Test Starter Kit

Starterkit for Premi®Test, includes accessories

1 Set

ZPT-2000

Premi®Test Multipress

Sampling device to squeeze 12 sample at once

1 unit

ZPT-2012

Real-time PCR

SureFast®

SureCycle

For validation of thermocycler

4 tests

F4001

SureCC Color Compensation Kit I

Color Compensation for multiplex application of
SureFood®/SureFast® kits on LC480

for 3 calibration runs

F4009

SureCC Color Compensation Kit II

Color Compensation for multiplex application of
SureFood®/SureFast® kits on LC2.0 and 1.5

for 3 calibration runs

F4010

SureInhibition Control

Test for inhibiting substances

100 reactions

F4050

SureFast® Animal+Plant Control

Extraction control

100 reactions

F4053

Premi®Test

78

Explanation
International standardisation and regulation authorities
AACCI

American Association of Cereal Chemists International

AFNOR

Association Française de Normalisation

AOAC

Association of Official Analytical Chemists
		
AOAC METHODS VALIDATION PROGRAMS:
• AOAC- RI
Performance Tested MethodsSM
• AOAC-OMA
Official MethodsSM
• AOAC-PTM
Peer-Verified MethodsSM

CEN

Comité Européen de Normalisation

Codex
Alimentarius
Commission

The Codex Alimentarius Commission, established by FAO and WHO in
1963 develops harmonised international food standards and
“Codex Methods of Analysis”.
The methods are primarily intended as international methods for the
verification of provisions in Codex standards. Definition of Codex types
of methods of analysis:
		
(a) Defining Methods (Type I) e.g. R5 Mendez ELISA method
(b) Reference Methods (Type II)
(c) Alternative Approved Methods (Type III)
(d) Tentative Method (Type IV)

FGIS

Federal Grain Inspection Service

GIPSA

Grain Inspection, Packers and Stockyards Administration

IDF

International Dairy Federation

IFU

International Federation of Fruit Juice Producers

ISO

International Organisation for Standardization

MicroVal

E uropean certification organisation for the validation and approval
of alternative methods for the microbiological analysis of food and
beverages

OIV

International Organization of Vine and Wine

79

R-Biopharm AG – Product catalogue 2017

The R-Biopharm Group – contact us
R-Biopharm AG
R-Biopharm Inc.

R-Biopharm
R-Biopharm
España S.A.U. Rhône Ltd.

R-Biopharm
Latinoamérica

R-Biopharm
Brasil Ltda.

R-Biopharm
France

R-Biopharm
Italia Srl.

R-Biopharm
Neugen Pvt. Ltd.

R-Biopharm
China

R-Biopharm
Australia

subsidiaries

R-Biopharm AG
An der neuen Bergstraße 17
64297 Darmstadt, Germany
Phone: +49 (0) 61 51 - 81 02-0
Fax: 			 +49 (0) 61 51 - 81 02-40
E-mail: sales@r-biopharm.de

www.r-biopharm.com

80

Argentina
R-Biopharm Latinoamérica S.A.
Vuelta de Obligado 2943
C1429 AVC Ciudad de Buenos Aires
Phone: +54 (0) 11 - 47 01 62 62
Fax:
+54 (0) 11 - 47 01 62 62
E-mail: info@r-biopharmlat.com.ar

India
R-Biopharm Neugen Pvt. Ltd.
2nd & 3rd Floor, Plot No. 7, C.F. Area, Phase II, IDA
Cherlapally, Hyderabad - 50 00 51 A.P., INDIA
Phone: +91 (0) 40 - 2980 - 5251/-4251 /-2324/-2321
Fax:
+91 (0) 40 - 27 26 60 - 33
E-mail: info@r-biopharm.in

Australia
R-Biopharm Australia
34 Woodfield Boulevard
Caringbah, NSW 2229
Phone: +61 (2) 2 - 96 68 06 00
Fax:
+61 (2) 2 - 96 68 85 33
E-mail: p.hill@labdiagnostics.com.au

Italy
R-Biopharm Italia Srl
Via Morandi 10
20077 Melegnano MI
Phone: +39 (0) 2 - 9 82 33 330
Fax:
+39 (0) 2 - 9 83 41 00
E-mail: info@r-biopharm.it

Austria
R-Biopharm AG, Christoph Reiterich
Phone: +43 (0) 66 41 - 35 21 22
Fax:
+49 (0) 61 51 - 81 02 - 40
E-mail: c.reiterich@r-biopharm.de

Netherlands
R-Biopharm AG, Michael Fijnenberg
Phone: +31 (0) 75 - 6 15 10 46
E-mail: m.fijnenberg@r-biopharm.nl

Brazil
R-Biopharm Brasil
Rua José Bonifácio, 768
Jardim Flamboyant
Campinas - SP
CEP 13091-140
Phone: +55 (0) 19 33 05 73 51
Fax:
+55 (0) 19 35 79 73 51
E-mail: vendas@r-biopharmbrasil.com.br
China
R-Biopharm Analysis Systems Trading (Beijing) Co. Ltd.
Suite 526 Building C, ULO PARK, No. 603
Wangjingyuan, Chaoyang District Beijing, China
100102
Telefon: +86 (0) 10 - 84 58 32 18
Fax:
+86 (0) 10 - 84 58 06 91
E-Mail: info@r-biopharm.cn
France
R-Biopharm France
Parc d’affaires de Crécy
5a rue Claude Chappe
69370 Saint-Didier au Mont D’Or
Phone: +33 (0) 4 78 - 64 32 00
Fax:
+33 (0) 4 78 - 47 84 04
E-mail: standard@r-biopharm.fr

Spain
R-Biopharm España S.A.U.
Sociedad Unipersonal
Los Manzanos 4
28703 S.S. De Los Reyes
Madrid
Phone: +34 (0) 9 02 - 90 33 - 55
Fax:
+34 (0) 9 16 - 54 89 92
E-mail: info@r-biopharm.es
Switzerland
R-Biopharm AG, Richard Blättler
Phone: +41 (0) 26 - 67 00 15 - 7
Fax:
+41 (0) 26 - 67 00 15 - 8
E-mail: r.blaettler@r-biopharm.ch
United Kingdom
R-Biopharm Rhône Ltd.
Block 10 Todd Campus
West of Scotland Science Park
Acre Road, Glasgow
Scotland, G20 0XA
Phone: +44 (0) 14 - 19 45 29 - 24
Fax:
+44 (0) 14 - 19 45 29 - 25
E-mail: info@r-biopharmrhone.com
USA/Canada
R-Biopharm Inc.
870 Vossbrink Dr.
Washington, MO 63090, USA
Phone: +1 (0) 8 77 - 7 89 - 30 33
Fax:
+1 (0) 8 66 - 9 22 - 58 56
E-mail: info@r-biopharm.com

81

R-Biopharm AG – Product catalogue 2017

General terms & conditions of R-Biopharm AG
(Date of issue: October 2010)
I. General provisions
These General terms & conditions only are valid for entrepreneurs, legal entities
under public law or public-law special assets (legal entities according to § 310 I
German Civil Code (“Bürgerliches Gesetzbuch” -”BGB”). We deliver according
to these General terms & conditions exclusively. They are deemed to have been
acknowledged with the placing of an order or the receipt of the goods and shall also
apply to all future business relationships, even if they are not explicitly agreed upon
again. Deviating terms and conditions are not binding for us, even if we do not object
to them explicitly.
II. Orders and offer documents
Our offers are subject to alteration. Decisive for the scope of our delivery obligation
are our offer in writing respectively our written order confirmation. Deliverable are
only the products which are contained in our current applicable price lists.
III. Prices and conditions of payment/Withdrawal in case of default
1. Purchase price is the price stated by us or - if no price has been stated - the price
which is contained in our price list, which is in effect on the day of the order. The
prices stated by us - unless otherwise stipulated in writing - are including packing and
shipping costs, excluding VAT. The deduction of cash discounts shall not be granted.
A small-quantity surcharge in the amount of 10 Euros can be charged for deliveries
with a product value of up to 300 Euros (small quantity).
2. Payment obligations resulting from the delivery of goods are to be fulfilled within
thirty (30) days of the invoice date by bank transfer exclusively and shall be deemed
to have been effected only to the extent, to which we can dispose of them freely at a
bank. For checks and bills of exchange, a processing fee of 30 Euros shall be charged;
discounting and expenses shall be for the account of the Buyer.
3. The Buyer shall only be entitled to set-off with a counter-claim which is undisputed or
has been determined by a final verdict. A right of retention the Buyer does only have
as far as it is resulting from the same contractual relationship.
4. Should the Buyer be in default with due payments entirely or partly, the regulations of
the statutory law are applicable. Interest in the amount of 8% above the basic interest
rate (as it is published by the German Federal Bank) shall be due. We are reserving the
right to claim any exceeding damage for delay.
5. In case of withdrawal, we are entitled - at the expense of the Buyer - to let the goods,
which have been delivered by us, mark, store separately and collect. The Buyer already yet - is declaring his consent that the persons who are commissioned with
the collection are entitled to access the premises, on which the goods are, and enter
them by car for this purpose.
6. In case of our withdrawal, we are not obliged to further deliveries any more, also
regarding further future deliveries.
IV. Retention of title
1. We shall retain title to the goods delivered by us, until all the claims, to which we are
entitled on whatever legal grounds arising from our business relationship with the
Buyer, have been fully satisfied. Upon the Buyer’s request, we shall be obligated to
release the securities in so far as their realizable value exceeds our claims by more than
10%. We reserve the right to select the items of collateral to be released.
2. The Buyer undertakes to only sell the goods, which are subject to retention, in his
ordinary course of business, according to his usual terms and conditions of business
and only as long as he is not in default with his payments. He is entitled to resell the
goods, which are subject to retention, only on the condition that a transfer of the
receivables, resulting from such a resale, to us takes place. He is not be entitled to
dispose of the goods, which are subject to retention, in any another way (such as e.
g. collateral assignment, pledging, leasing, lending, etc.). The Buyer is obligated to
immediately notify us of any seizure or other interference by a third party, together
with handing over of the documents which are necessary for an intervention.
V. Delivery
1. Our delivery times are generally only approximate and not binding.
2. Uncontrollable incidents, for which we are not responsible, e. g. natural phenomena,
war, orders of the authorities, embargo, unexpected delays in the delivery of essential
components and other materials (“Force Majeure”), shall prolong the delivery time
reasonably. This also applies, if these incidents occur during a delay in delivery or at
a sub-supplier. However, the delivery time shall be prolonged by a maximum period
of two (2) months. Should we also not be able to deliver after this time, then the
Buyer as well as we themselves are entitled to withdraw from the contract. Any claims
of damages of the Buyer for this reason are excluded. Should we withdraw from
the contract, we shall immediately refund the Buyer any and all payments possibly
rendered for not yet delivered goods.
3. Should the Buyer - despite reminder - not fulfill his payment obligations resulting
from existing contracts, we shall only supply on advance payment from then on.
4. We are entitled to partial deliveries to a reasonable extent; here each partial delivery
can be invoiced separately. In case of order on call, the call-off has to take place at
least two (2) calendar weeks prior to the desired delivery date.
VI. Shipment and passing of risk
1. Dispatch ex works or distribution warehouse shall be carried out at the expense of
the Buyer. Shipping route and mode of dispatch shall be determined by us. We shall
only be obligated to obtain a transport insurance, if explicitly instructed to do so by
the Buyer in writing; the Buyer shall bear the costs for this insurance.

82

2. The passing of risk to the Buyer takes place as soon as the goods have been
handed over to the haulage contractor respectively leave our factory or distribution
warehouse for the purpose of dispatch; this also is valid, if we - by way of exception organize additional services, e. g. carriage prepaid shipping, delivery to the premises
of the Buyer, or similar. In particular we are not liable for alteration or deterioration
of the goods during transport or resulting from improper storage. Should we have
notified the Buyer that the goods are ready for dispatch or collection, the risk passes
on to the Buyer, if he does not have the goods delivered or collect them, despite of us
having set him a reasonable period of time for doing so; regarding that, the passing
of risk takes place at the beginning of the day which follows the day, on which the
deadline has expired.
VII. Warranty/liability
1. It is precondition for the execution of claims based on a defect, that the Buyer has
performed his responsibilities to examine and complain according to § 377 of the
German Commercial Code (“Handelsgesetzbuch” -”HGB”) correctly and completely.
2. We are liable for faultlessness of the goods corresponding to the state of the art.
Features of samples and specimens as well as any statements regarding the condition
of the goods, shall only be considered as an agreement on quality, if they explicitly
have been agreed upon as determining the condition of the goods. Otherwise they
are non-binding and do not free the Buyer from an own inspection of the goods
concerning their suitability for his purposes. We neither grant guarantees with the
content of a liability without fault nor any other kind of guarantees for quality and
durability in the legal sense.
3. We are not liable for damages as far as they have been caused by improper storage of
our products and/or their application contrary to the prescriptions - e. g. application
after expiry of their shelf life or contrary to the direction for use - or as far as they have
been caused by the Buyer in any other way.
4. The exceeding of use-by dates after the delivery does not entitle the Buyer to claims
of any kind, but is deemed to be the usual condition. This is not the case, if the period
between the date of delivery and the use-by date is less than four (4) calendar weeks.
5. We shall only be liable for damages, as far as we attributable have caused them by
intent or gross negligence (disregard for the due care and attention to a very coarse
extent); except in case of violation of essential contractual obligations (obligations,
whose fulfillment enables the proper execution of the contract at all and on whose
observance the contractual partner may rely regularly). In this last-mentioned case
we are liable for each negligence with the restriction that - in case of violation of
essential contractual duties by slight negligence - our liability is limited to the damage
which typically is predictable.
6. Should we not have violated any essential contractual obligations in the sense
mentioned before, we are not liable in cases of slight negligence. Unaffected by any
limitation of liability contained in these General Terms & Conditions stay: Liability for
intent, malice, initial inability, gross negligence, liability resulting from a guarantee
(which, however, we generally not grant), bodily harms and other cases of legally
compelling liability - in these cases the statutory law is valid (under exclusion of the
Terms and Conditions of our contractual partner).
7. The regulations of this clause Warranty/Liability are valid for our contractual liability as
well as liability resulting from tort (unaffected thereby stays the action for possession
in case of tort, after statutory limitation has taken place, § 852 German Civil Code
(“Bürgerliches Gesetzbuch” -BGB”)).
8. As far as our lability is excluded or limited, this shall also apply to the personal liability
of our representatives, employees and vicarious agents and our liability for them.
9. As far as there is a defect of the goods, for which we are liable, the Buyer has to
grant us the opportunity to execute subsequent performance within a term of
generally two (2) calendar weeks, before the assertion of his further rights. In case
that subsequent performance fails twice, in case of our refusal, or if subsequent
performance is impossible, is delayed unreasonably or unreasonable for the Buyer
due to other reasons, the Buyer may - according to his choice - execute his further
legal rights, namely rescission or reduction of the purchase price and (regarding
defects for which we are liable) claim of possibly occurred damages or compensation
for possible futile expenditure, by which our liability is limited according to the
preceding regulations.
VIII. Burden of proof/export/effectiveness
1. With none of the stipulations of these General terms & conditions an alteration of the
burden of proof is intended.
2. We are not liable for the correctness of information regarding foreign-trade which
we provide to our best conscience; it is the Buyer´s responsibility to assess the
compliance with foreign-trade regulations with regard to our products himself.
3. Should any of the regulations of our General Terms & Conditions be ineffective and/
or incomplete, the validity of the other regulations shall remain unaffected thereby.
IX. Applicable law and place of jurisdiction
1. The contractual relationship shall be governed by the laws of the Federal Republic of
Germany, which shall be applicable supplementary. The UN-convention on contracts
regarding the International Sale of Goods (CISG) shall not apply.
2. Exclusive Place of Jurisdiction is Darmstadt (Germany). However, we are entitled to
file a lawsuit against the Buyer also at any other court, which does have jurisdiction
regarding him according to the general regulations.

83

R-Biopharm AG

R-Biopharm AG

03/2017

An der neuen Bergstraße 17
64297 Darmstadt, Germany
Phone: +49 (0) 61 51 - 81 02-0
Fax:
+49 (0) 61 51 - 81 02-40
E-mail: info@r-biopharm.de
www.r-biopharm.com

R-Biopharm – for the safety of your analysis.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Create Date                     : 2017:06:28 09:04:33+02:00
Metadata Date                   : 2017:06:28 09:14:39+02:00
Modify Date                     : 2017:06:28 09:14:39+02:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:f0203f97-78a5-4375-aeda-17540cd4a373
Original Document ID            : xmp.did:8FEA4B865A3FE511954D80537053F4D4
Document ID                     : xmp.id:8BEC6936CF5BE71189FEB7466A2CF006
Rendition Class                 : proof:pdf
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2017:06:28 09:04:33+02:00
Derived From Instance ID        : xmp.iid:8AEC6936CF5BE71189FEB7466A2CF006
Derived From Document ID        : xmp.did:8FEA4B865A3FE511954D80537053F4D4
Derived From Original Document ID: xmp.did:8FEA4B865A3FE511954D80537053F4D4
Derived From Rendition Class    : default
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Mode                       : UseOutlines
Page Count                      : 84
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu