Elster Solutions ELIR1 ELSTER LIGHTING INTELLIGENCE User Manual

Elster Solutions, LLC ELSTER LIGHTING INTELLIGENCE Users Manual

a href="https://usermanual.wiki/Elster-Solutions" itemprop="url"> Elster Solutions >

Users Manual

DescriptionPart of the DimOnOff wireless control technology, Litenode relays are suitable for general purposelighting control applications that add intelligent functions and networkability to any light fixture. Therelay provides continuous retroactive 0 V to 10 V (sink/source) for all types of ballasts and drivers andprovide power to external sensors (optional).• intelligent distributed control, metering, and monitoring• NEMA C136-41• 5- and 7-pin with continuous retroactive 0 V to 10 V dimmingOperationUnless otherwise programmed, the relay will turn on the fixture approximately 10 seconds after poweris restored to the relay.The yellow LED will blink when power is properly applied.Using DimOnOff software, test the communications link with the relay.Before you install• This device is to be installed and/or used in accordance with appropriate electrical codes andregulations.• If you are unsure about any part of these instructions, consult a qualified electrician.• Use this device only with NEMA C136-41 or C136-10 certified receptacles.Use authorized utility procedures to install or service this device. Dangerous voltages are present.Disconnect power at the circuit breaker or fuse when servicing, installing, or removing the light fixture.Equipment damage, personal injury, or death may result if safety precautions are not followed.Litenode™ wireless nodeSingle load RME-GENInstallation instructionsIL42-5047ADRAFT
Litenode™ wireless node 2InstallationUse authorized utility procedures to install or service this device. Dangerous voltages are present.Disconnect power at the circuit breaker or fuse when servicing, installing, or removing the light fixture.Equipment damage, personal injury, or death may result if safety precautions are not followed.If you are uncertain about any part of these instructions, consult a qualified electrician.The node input and output are low voltage (24 VDC). Consult local building codes and regulations forinformation regarding low-voltage installation.1 To avoid fire, shock, or death, be sure to turn off power at the circuit breaker or fuse. Verify that power is off before proceeding.2 Connect lead wires according to the wiring diagram as follows:- Line voltage wiring: Remove 5/8-inch (1.6 cm) of insulation from each circuit conductor. Make surethat the ends of the conductors are straight. Connect lead wires from relay to line per theappropriate wiring diagram as follows. Twist strands of each lead tightly and, with circuitconductors, push firmly into the appropriate wire connector. Screw connectors on clockwisemaking sure that no bare conductor shows below the wiring connectors. Secure each connectorwith electrical tape.- Class II warning: Connect low-voltage wires from relay to fixture per appropriate wiring diagramas follows. Twist strands of each lead tightly, and with circuit conductors, push firmly intoappropriate wire connector. Screw connectors on clockwise, making sure that no bare conductorshows below the wire connectors. Make sure to cap-off unused low-voltage wires. Secure eachconnector with electrical tape.3 Restore power at circuit breaker or fuse.RME-GEN wiringLine wires on C-136 socket supplied by othersColor GaugeLine in Black 14Neutral/line 2 White 14Line out Red 14DC control wires on C-136 socket supplied by others0Vto10V+out Purple 180 V to 10 V- ground out Gray 18Digital in 13 VDC to 30 VDC Orange 18VCC 24 VDC 50 mA Brown 18DRAFT
Download:
Mirror Download [FCC.gov]
Document ID2958583
Application IDflhEEANNXfP2lofWrZ/lMA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize5.39kB (67401 bits)
Date Submitted2016-04-13 00:00:00
Date Available2016-04-15 00:00:00
Creation Date0000-00-00 00:00:00
Document Lastmod0000-00-00 00:00:00
Document TitleUsers Manual
FCC ID Filing: QZC-ELIR1

Navigation menu