Emerson Process Management Electric Co Thermostat 1F95 1291 Users Manual 1291_37 7313B
White-Rodgers-1F95-1291-Emerson-Big-Blue-12-Humidity-Touchscreen-Thermostat-Installation-And-Operation-Instructions-676999 white-rodgers-1f95-1291-emerson-big-blue-12-humidity-touchscreen-thermostat-installation-and-operation-instructions-676999
1f951291 65cf60bf-5368-475a-adea-612aa432bda4 Emerson Process Management Thermostat 1F95-1291 User Guide |
2015-02-06
: Emerson-Process-Management Emerson-Process-Management-Emerson-Process-Management-Emerson-Electric-Co-Thermostat-1F95-1291-Users-Manual-540149 emerson-process-management-emerson-process-management-emerson-electric-co-thermostat-1f95-1291-users-manual-540149 emerson-process-management pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
Big Blue Humidity Universal Thermostat with Humidity/Dehumidity Control and Automatic Heat/Cool Changeover Option Single Stage, Multi-Stage, Heat Pump Installation and Operating Instructions Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Model 1F95-1291 Programming Choices 7 Day 5+1+1 Day Non-Programmable APPLICATIONS 1F95-1291 Humidity Control Touchscreen Thermostat THERMOSTAT APPLICATION GUIDE Maximum Stages Heat/Cool Thermostat Configuration Options Thermostat Applications Single Stage 1 No Heat Pump (SS1) Multi Stage 2 No Heat Pump (MS2) Gas, Oil, Electric, Heat Only, Cool Only or Heat/Cool Systems, 2 or 3 wire Hydronic Zone (Hot Water or Steam) Systems, 24 Volt or Millivolt Heat Pump 1 Single Stage Compressor Heat Pump (HP1) Single Stage Compressor Heat Pump Systems - up to 2 Stages Aux./Emergency Heat 3+1 Heat Pump 2 Two Stage or Two Compressor Heat Pump (HP2) Two Stage or Two Compressor Heat Pump systems - up to 2 Stages Aux./Emergency Heat 4+2 1+1 2+2 SPECIFICATIONS Electrical Rating: Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . . Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rated Differentials: Heat (Single Stage/Multi-Stage) . . . . . . . . . . . . Cool (Single Stage/Multi-Stage) . . . . . . . . . . . . Heat Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Emer Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . Shipping Temperature Range . . . . . . . . . . . . . . . . . . Dimensions Thermostat . . . . . . . . . . . . . . . . . . . . . . Humidity Setpoint Range . . . . . . . . . . . . . . . . . . . . . Dehumidification Setpoint Range . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC 20 to 30 VAC 1.5A per terminal, 2.5A maximum all terminals combined 45 to 99°F (7 to 37°C) Fast. Slow 0.6°F 1.5°F 1.2°F 1.7°F 1.2°F 1.7°F 0.6°F 1.7°F 32°F to +105°F (0 to +41°C) 90% non-condensing max. -40 to +150°F (-40 to +65°C) 4-9/16"H x 5-13/16"W x 1-3/16"D 5 to 50% 40 to 95% ! CAUTION To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. Index Installation Wiring Diagrams Thermostat Quick Reference Installer Configuration Menu Operating Your Thermostat Programming Troubleshooting Page 2 3 5 6 10 12 15 ATTENTION: MERCURY NOTICE This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container. Refer to www.thermostat-recycle.org for location to send the product containing mercury. PART NO. 37-7313B www.white-rodgers.com www.emersonclimate.com Replaces 37-7313A 1241 INSTALLATION ! WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. Remove Old Thermostat Before removing wires from old thermostat, mark wires for terminal identification so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the thermostat base. Forcing or prying on the thermostat will cause damage to the unit. 2. Place base over hole in wall and mark mounting hole locations on wall using base as a template. 3. Move base out of the way. Drill mounting holes. If you are using existing mounting holes and the holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure the base. 4. Fasten base snugly to wall using mounting holes shown in Figure 1 and two mounting screws. Leveling is for appearance only and will not affect thermostat operation. Thermostat Power Method Switch Position/Description Battery Powered, no 24 Volt system power available. Switches "On", thermostat runs on batteries. Hardwired with Battery Back-up, for 24 Volt systems with common connection from transformer to "C" terminal on thermostat. Switches "On", thermostat runs on power directly from transformer with battery backup. *Battery Powered with Power Stealing Assist, for 24 Volt systems with no common connection from transformer to "C" terminal on thermostat. Switches "On", thermostat runs on batteries and supplemental power drawn through the heat or cool circuit. *Power Stealing Assist is very reliable to increase battery life, but on a small number of heating or cooling systems with high impedance electronic modules you may observe one of the following conditions: 1. The furnace draft inducer motor may run with no call for heat. 2. The furnace fan may turn on with no call for heat or may not turn off. 3. The furnace may not turn off when the call for heat ends. 5. Connect wires to terminal block on base using appropriate wiring schematic. 4. The air conditioner may not turn off when the call for cool ends. 6. Push excess wire into wall and plug hole with a fire resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation. If the Power Stealing Assist method is not compatible with your system, place the Power Stealing Switches to "Off". This cancels Power Stealing Assist, operates the thermostat on batteries and corrects the condition. 7. Carefully line the thermostat up with the base and snap into place. Figure 1 – Thermostat Base Multi-Stage 1F95-1291 Battery Location 2 "AA" alkaline batteries are included in the thermostat at the factory with a battery tag to prevent power drainage. Remove the battery tag to engage the batteries. To replace batteries, set system to OFF, remove thermostat from wall and install the batteries in the rear along the top of the thermostat (see Figure 1). For best results, use a premium brand "AA" alkaline battery such as Duracell® or Energizer®. If the home is going to be unoccupied for an extended period (over 3 months) and is displayed, the batteries should be replaced before leaving. Power Stealing Switches The Power Stealing Switches (Fig. 1) should be left in the "On" position for most systems. The information in the following table details the thermostat power method and switch options. Mounting Hole + O/B L S Y2 - Y HM W2 Mounting Hole W/E 6 DHM Place Level across Mounting Tabs (for appearance only) Place Level across Mounting Tabs (for appearance only) Rear view of thermostat 2 "AA" Batteries Stack Power Stealing Switch 2 Power Stealing Switches WIRING DIAGRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer System RC RH C Y Single Stage 1 (SS1) Multi Stage 2 (MS2) Call for cool 24 volt common (optional 24 volt for system power for operation, heating required Cool mode-1st for remote stage sensor) 24 volt power for cooling Y2 W/E W2 No Output Call for heat No output Cool mode-2nd stage Heat mode-1st stage Heat mode-2nd stage G O/B 6 Blower/Circulator fan energized on a call for cool or Fan On (also energized in heating if configured for Electric Heat) Installer Configuration Menu selects “O” or “B” for changeover function. Set to “O” terminal energized in Cool & Off mode. Set to “B” terminal energized in Heat & mergency mode L Fault or System Malfunction Indicator for Power closed Heat Pumps connection for with “L” terminal SPDT 3-wire connection. zone valve Original production 1F95-1291’s do not have this connection NEUTRAL 24VAC 120VAC HOT Single Stage and Multi-Stage Connections Single stage (SS 1) gas, oil or electric. Refer to equipment manufacturers’ instructions for specific system wiring information. Multi-stage (MS 2) gas, oil or electric. This thermostat is designed to operate a single-transformer or twotransformer system. After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration. CLASS II TRANSFORMER You can configure the thermostat for use with the following fossil fuel systems: Figure 3 – Heat Pump Systems System RC RH C Y Heat Pump 1 (HP1) Y2 No Output 24 volt power for cooling Heat Pump 2 (HP2) 24 volt common Heat mode-1st (optional 24 volt stage, for system power for Cool mode-1st operation, heating stage, required (Compressor) for remote sensor) *W/E *W2 Heat mode-2nd stage, Emergency Mode-1st stage *Note: Dual Fuel option deenergizes Heat mode stage 1 (compressor) when auxiliary heat is energized Heat mode-3rd stage, Emergency Mode-1st stage Heat mode-2nd stage, Cool mode-2nd stage, (Compressor) *Note: Dual Fuel option deenergizes Heat mode stages 1 and 2 (both compressors) when auxiliary heat is energized G 120VAC HEATING L Fault or System Malfunction Indicator for Heat Pumps with “L” terminal connection. Original production 1F95-1291’s do not have this connection NEUTRAL 24VAC 24VAC HOT 6 Heat mode-3rd stage, Emergency Mode-2nd stage *Note: Dual Fuel option deInstaller energizes Heat Configuration mode stage 1 Menu selects (compressor) “O” or “B” for when auxiliary Blower/Circulator fan changeover heat is energized energized on a call Power closed function. Set connection for for cool or Fan On to “O” terminal SPDT 3-wire (also energized in Heat mode-4th energized in Cool zone valve stage, Emergency heating if configured & Off mode. Set for Electric Heat) Mode-2nd stage to “B” terminal energized in *Note: Dual Fuel Heat & mergency option demode energizes Heat mode stages 1 and 2 (both compressors) when auxiliary heat is energized NEUTRAL 120VAC O/B 120VAC HOT COOLING *Dual fuel option, if selected turns off compressor(s) when Auxiliary stages energize. CLASS II TRANSFORMER CLASS II TRANSFORMER Heat Pump Connections If you do not have a heat pump system, refer to figures 3 & 4. Refer to equipment manufacturers’ instructions for specific system wiring information. You can configure the thermostat for use with the following heat pump systems. HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas or electric backup. HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two compressor system with gas or electric backup. After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration. 3 WIRING DIAGRAMS Figure 4 – Humidity and Sensors HM DHM + S - Humidification Terminal, Energizes on call for heat if Humidity setpoint is above room humidity. Can also be used to provide humidification independent of a call for heat and/or in cooling mode if Automatic Humidification is selected in Configuration Menu item #34 De-energizes on call for Dehumidification to lower the fan speed. The DHM terminal is only used on systems with a compatible dehumidification feature that have the required terminal connection on the contol module or have a relay installed to lower the fan speed Supply voltage to remote temperature sensor Remote temperature sensor signal Supply voltage to remote temperature sensor Dehumidification wiring without an electronically controlled variable speed blower system for single stage compressor system only. If you have a single stage compressor system see the diagram below. A relay (customer provided) should be installed as shown in Fig 7 to switch the fan speed to the next lower speed on a call for dehumidification from the thermostat. The reduction in air flow allows the coil to remove more humidity from the air. The relay should be rated for blower motor load. Since this configuration reduces the air flow in cooling, the anti-freeze-up control (White-Rodgers CAFC) or equivalent is recommended. The CAFC prevents the air conditioning coil from freezing due to low air flow, dirty filters, low refrigerant pressure, etc. The CAFC snaps onto the suction line close to the evaporator coil as possible and breaks the compressor circuit when the suction line drops below 38°F and re-make the circuit at 46°F. Figure 5 – Typical Wiring for Dehumidifier System Normal High DHM No Relay 90-293Q or equivalent N Med 1 Low 2 Dehum Speed Fan NC “Heat Fan Output” “Cool Fan Output” 1 2 Normal Cool speed position (DHM energized) Dehum speed mode (DHM de-energized) N Figure 6 – Typical Wiring for 120V Humidifier System R HM Relay 90-290Q or equivalent HOT 24 VAC HOT Humidifier System NEUTRAL NEUTRAL TRANSFORMER 120 VAC Figure 7 – Typical Wiring for 24V Humidifier System R HM Humidifier System HOT 24 VAC NEUTRAL TRANSFORMER 4 120 VAC 120 VAC THERMOSTAT QUICK REFERENCE Home Screen Description Figure 8 – Home Screen Display Room Temperature Day of Week Set Temperature/Humidity Time of Day Note: If is displayed, the thermostat is battery powered. When battery power remaining is approximately half, will be displayed. If the home is going to be unoccupied for an extended period (over 3 months) and is displayed, the batteries should be replaced before leaving. Temperature UP/Down used for modifying setpoint as well as to navigating the menus System Switch Fan Switch Press to view Humidity setpoint Indicates when thermostat is calling for Heat or Cool Programming and Configuration Items 16 1 2 3 17 4 5 6 7 8 9 11 10 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 12 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 21 9 8 2 Indicates period of day being programmed. 4 SET TIME key or HOLD temperature key. 5 Displays "Change Filter"/"Change Pad"/"Change UV Lamp" when the system has run for the programmed filter/humidity pad/UV lamp time period as a reminder to change or clean your filter/humidity pad or to replace UV lamp. Battery Level Indicator Indicating the current power level of the 2 “AA” batteries. Full power remaining. Half power remaining. Change The batteries should be replaced at this time. Figure 9 – Programming & Configuration Items 1 Displays and "Keypad Lockout" when in keypad lockout mode. Displays and "Temperature Limit" and "Keypad Lockout" when limited range is activated and locked. Displays only "Temperature Limit" when limited range is activated. 3 RUN SCHEDULE (run program) key. Menu key for entering different modes such as Cleaning, Configuration, Set Time and Set Schedule 1 18 2 14 13 20 15 3 6 COPY key or INSTALLER CONFIG key. 19 7 CLEAN DISPLAY key allows 30 seconds to wipe off the display or ADVANCE DAY key for programming. 8 Used in programming to set time and in configuration menu to change selections. 9 "Hold Until" indicates the time when a temporary hold period will end. 10 "Hours" and "Days" displays during steps in installer configuration. 11 The words "Hold At" are displayed when the thermostat is in the HOLD mode. "Temporary Hold At" is displayed when the thermostat is in a temporary HOLD mode. 12 "Humidity" indicates that the "Set At" display is Humidity setpoint. 13 "System On" indicates when heating or cooling stage is energized. "+2" indicates when a second stage is energized. 14 "Copy" indicates the copy program feature is being used during programming. 7 6 4 5 15 A steady "Cool Savings" display indicates the feature is enabled in the installer menu. A flashing "Cool Savings" display indicates the feature is active. 16 "Remote" indicates that the indoor remote temperature sensor, is being accessed. "Outdoor Remote" indicates the outdoor remote temperature sensor is being accessed. 17 Display time, remote temperature or humidity. 18 "Heat Pump" displays when the system configuration is set in HP1/HP2. 19 "Call for Service" indicates a fault in the heating/cooling systems. It does not indicate a fault in the thermostat. 20 Auto Schedule key for Auto Schedule function or Humidity key to display current Humidity and Humidity setpoint. 21 In Configuration Menu, shows screen number. If blank, thermostat is earlier model and requires instruction sheet 37-6914E. 5 INSTALLER/CONFIGURATION MENU To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays screen reference #1 in the table below. Screen Reference numbers appear in top right corner of display. Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item option. Shaded items are not available if selected for Non-Programmable. Write the options selected in the "Option Selected" column of the menu. Installer Note: To default the programming, clock and Configuration Menu to the Factory Default Settings, press the , and SYSTEM keys simultaneously. The thermostat display will go blank for a few seconds, and then all segments will display momentarily. For heat pump systems, Configuration Menu items 1 and 3 must be set to match the heat pump system. CONFIGURATION MENU Screen SS1 Reference MS2 Number Press or to select from listed options 1 MS 2 HP 1, HP 2, SS 1 2 (gas) ele 0b (0) b 3 4 Days, (7) P 5 or 0 5 (4) PS 2 6 Comments Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1 (HP1, 1 compressor), Heat Pump 2 (HP2, 2 compressor or 2 speed compressor), or Single Stage. GAS setting: furnace controls blower. ELE setting: thermostat controls blower. Selects Reversing Valve (This item is only to appear if HP1 or HP2 is selected above.) Programs per week. (7 days, 5+1+1 days or non-programmable) Programs per day. = Morning, Day, Evening, Night 4 2 = Day, Night Not available if 4 is 0 Cool-Off-Heat, Heat Off, System switch configuration in non heat pump mode. Heat, Cool-Off, Auto Off Cool-Off-Heat-Em, System switch configuration, heat pump mode. Off-Em-Auto OFF Selects Energy Management Recovery. Not available if 4 is 0 7 Cool-OffHeat-Auto Cool-Off-HeatEm-Auto (On) E 8 (FA) Heat, Cr SL Selects Adjustable Anticipation, cycle rate, Heat 9 (FA) Cool, Cr SL Selects Adjustable Anticipation, cycle rate, Cool (FA) Cr/AU, Em SL On Selects Adjustable Anticipation, cycle rate auxiliary, (This item is only to appear if HP1 or HP2 is selected above). Selects Compressor Lockout. 10 11 (OFF) CL 12 (On) dL OFF 13 5, LO to 5, HI 14 0 (Temperature) °F 15 (On) b OFF Selects audible Beeper On/Off. 16 (On) dS OFF Selects Daylight Saving Time calculation. 17 (On) Heat, AS OFF 18 (On) Cool, AS OFF 19 (OFF) CS On Selects Automatic Schedule for comfort temperature Programming, heat mode. Not available if 4 is 0 Selects Automatic Schedule for comfort temperature Programming, cool mode. Not available if 4 is 0 Selects Cool Savings Feature On of Off. 20 1-2-3-4-5-6 21 CS Cool Savings (3) (Off) CO On Select Compressor Optimization (not available on earlier models) 22 (OFF) CA On 23 (99) Heat, HL 62-98 Selects Comfort Alert Feature On or Off. (not available on earlier models) TEMPERATURE LIMIT, HEAT (max. heat set point). 24 (45) Cool, LL 46-82 TEMPERATURE LIMIT, COOL (min. cool set point). 25 26 000 001-999 27 (On) Heat, FS OFF 28 (On) Cool, FS OFF 29 Remote (OFF) On 30 Remote, In Outdoor Remote 31 (On) LS OFF (OFF) dF On 32 6 HP1 Press HP2 key Displayed Factory (Default) OFF, Keypad Lockout °C L (total), P (partial), Temperature Limit Selects Continuous Display backlight. Selects Adjustable Ambient Temperature Display [range -5 (LO) to +5 (HI)]. Selects °F/°C Display (temperature units in Fahrenheit or Celsius). Selects amount of Cool Savings adjustment. Selects Keypad Lockout. (limited temperature range) Selects Keypad Lockout Combination (active only if keypad Lockout is selected). Fast second stage of heat (not available if SS1 is selected above). Fast second stage of cool (not available if SS1 or HP1 is selected above). Remote temperature sensor, enable/disable. Remote temperature sensor (Indoor/Outdoor). Local temp. Sensor enable/disable (only when Indoor Remote is selected On). Selects Dual Fuel feature On or OFF (this item appears if HP1 or HP2 is selected above). Option Selected INSTALLER/CONFIGURATION MENU CONFIGURATION MENU Screen SS1 Reference MS2 Number HP1 Press HP2 key Displayed Factory (Default) Press or to select from listed options 33 (35) dF -5 - 50 34 (05) dF 0 - 09 35 (60) Cd 0-99 36 (80) AO -5 - 79 37 (80) bP 79-20 Comments Selects Dual Fuel setpoint (°F), dF selected On with outdoor sensor available. Selects Dual Fuel setpoint (°F), dF selected On with no outdoor sensor. Selects compressor off delay in seconds, dF selected On Selects Auxiliary Heat cut out temperature. This item appears if HP1 or HP2 is selected and outdoor sensor is installed and enabled. Selects Blower balance point. Selection of 80 disables this feature. This item appears if HP1 or HP2 is selected and outdoor sensor is installed and enabled. Selects Humidity Display alternate with time. 38 (OFF) Hd on 39 40 Humidity 00 (Room Humidity) (OFF) HR -20 LO 20 HI LO, HI Selects Auto Humidity reduction. 41 (OFF) AH H, C, A Selects Automatic Humidification. 42 (OFF) CH On 43 OC (0) od, OFF 44 On 45 (OFF) Change UV Lamp 350 Days 46 47 48 49 (OFF) Change Pad 100 Hrs OFF Change Filter 200 Hrs 25-1975 Selects Humidity Display adjustment. Selects Cycle Humidifier. Selects Optimum Comfort or Optimum Dehumidification or Off. Selects Change UV Lamp feature. Change UV Lamp duration days. On Selects Change Humidifier Pad feature. 25-1975 Change Humidifier Pad duration hours. On Selects Change Filter feature. 25-1975 Change Filter duration hours. 1. This control can be configured for: MS2 – Multi-Stage System (2 heat/2 cool) HP1 – Heat Pump with one stage of compressor (2 heat/1 cool) HP2 – Heat Pump with two stage compressor or two compressor system, Gas or Electric backup; (Dual Fuel see screen reference number 33) (4 heat/2 cool) SS1 – Single Stage System (3 wire zone see wiring diagrams. 2. GAS or Electric (ELE) fan operation. If the heating system requires the thermostat to energize the fan, select ELE. Select GAS if the heating system energizes the fan on a call for heat. Note: Resetting the thermostat switches the option to GAS. 3. O/B Terminal selection – Selects the operation of the reversing valve (when item 1 is set to HP1 or HP2 only). When set to "O" the changeover valve will be energized in COOL to accommodate the majority of heat applications. If the heat pump requires the changeover valve to energize in HEAT, select "B". 4. Programs per week – This control can be configured for 7 independent day or 5+1+1 day programming or nonprogrammable modes. Default is 7-day mode. The display indicates "7 Days" as default. Other options "5 Days" or "0 Days" can be selected. If "0 Days" is selected for nonprogrammable mode, the step for EMR will be skipped, as this feature will not be available in this mode. 5. Program Steps per day – Not available if configured for non-programmable. This control can be configured for 4 or 2 program steps per day. Default is "4 PS" and can be toggled between 4 PS and 2 PS. Option Selected 6. System Switch Configuration (MS2/SS1) – This thermostat is configured for Heat and Cool with Auto changeover default (Cool-Off-Heat-Auto). It can be configured as Heat & Cool (Cool-Off-Heat), or Heat Only (Off-Heat), or Cool Only (Cool-Off). When the control is in heat pump configuration (HP1/ HP2), the system switch configuration will have an additional mode, Em for Emergency. 7. Energy Management Recovery (EMR) – (this step is skipped if configured as non-programmable). When set to "On" causes the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Example: The heating program is 65°F at night and 70° at 7 AM. If the building temperature is 65°F, the difference is 5°F. Allowing 5 minutes per °F rise, the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows more time per °F, because it takes longer to reach temperature. 8, 9 & 10. Cycle Rate Selection – The factory default setting is fast cycle (FA Cr) in all modes (Heat, Cool, Em). To or change to slow cycling (SL, Cr), press touch keys toggle between FA & SL. The cycle rates are below: Mode Med Slow Heat 0.6°F 1.5°F Cool 1.2°F 1.7°F Heat Pump 1.2°F 1.7°F Emer Heat 0.6°F 1.7°F 11. Select Compressor Lockout (CL) – Selecting (CL On) will cause the thermostat to wait 5 minutes between cooling cycles. This is intended to help protect the compressor from short cycling. Some of the newer compressors have 7 INSTALLER/CONFIGURATION MENU a time delay built in and do not require this feature to be activated in the thermostat. Your compressor manufacturer can tell you if this lockout feature is already present in their system. When the thermostat compressor time delay is activated, it will flash the set point for up to five minutes. 12. Select Continuous Display Lighting (dL) – In low lighting conditions, display backlight improves the display contrast. When C terminal is connected, selecting dL On will turn the display light on continuously. Selecting dL Off will turn the display light on momentarily after any key is pressed. When C terminal is not powered (battery only), dL On enables the momentary backlight whenever a key is pressed. Continuous Display Lighting without common wire connection – When thermostat is Battery Powered with Power Stealing assist with low voltage 24V connections to both W and Y terminals, selecting dL "On" will provide continuous display light. Note: If power stealing operation is not compatible with either the W or Y connection (see page 2), or if only a single connection to W or Y, continuous display light will be interrupted when the active power stealing connection (W or Y) is operating the system. In power stealing mode, the continuous display light will increase in brightness when a button is pressed. And on some systems with high impedance, the display light may dim slightly when thermostat is calling for heat or cool. 13. Select Temperature Display Adjustment 5 LO to 5 HI This allows you to adjust the room temperature display by -5°F to +5°F in 1° steps. Your thermostat was accurately calibrated at the factory, however you have the option to change the display temperature value to match the previous thermostat, if you so prefer. 14. Select °F or °C Readout – Changes the display readout to Celsius or Fahrenheit as required. 15. Select Audio Prompting (Beeper) On or Off – Factory default setting is b, On. If you wish to turn off the beeper select OFF. 16. Select Daylight Saving Time Calculation – This feature will allow the thermostat to calculate the DST automatically and apply it to the Real Time Clock display. Default is On. 17 & 18. Select Automatic Schedule – Not available if configured for non-programmable. This feature allows programming a “Comfort Temperature” into all program periods with the Auto Schedule key. When Heat AS (for Heat mode) or Cool AS (for Cool mode) is selected On, the Auto Schedule feature is ready to be set. Off indicates that the feature is not ready to be used or a “Comfort Temperature" is already set. See Auto Schedule in Programming section. 19 & 20. Select Cool Savings™ – Cool Savings™ provides an energy saving temperature offset (from 1-6 degrees) under peak cooling load conditions (high outdoor temperatures). If selected on, Cool Savings™ becomes active when the air-conditioner runs for periods of longer than 20 minutes. When active, Cool Savings™ gradually offsets the indoor temperature display downward. The first 1° of adjustment will take one hour of continuous air conditioner run time with subsequent 1° adjustments occurring with each additional half hour of run time (ex for a 2° offset, the air conditioner would need to run continuously for 1 ½ hours). The offset is limited to the number of degrees you select from 1 up to 6. When an offset starts or is active, “Cool Savings” will flash on the display. The principle of this energy saving feature takes advantage of the long air conditioning run times lowering the indoor 8 humidity allowing a slightly higher temperature to feel comfortable. As the peak load subsides, this feature also takes advantage of the air conditioner's increased capacity under more efficient conditions to gradually reduce the offset back to zero and return control to the selected setpoint temperature. If Cool Savings is selected off, no temperature offset will occur. 21. Compressor Optimization – (Not available on earlier models) CO provides a delay in circulator fan operation after the compressor turns on or off. With CO selected ON, when the compressor turns on (for a call for heat in heat pump or a call for cool) the fan will be delayed for five seconds before turning on to allow the air to be heated or cooled. After the compressor turns off for call for cool, the fan will continue to run for 20 seconds to capture additional cooling from the system. If CO is set to OFF, there will be no delay in fan operation. 22. Comfort Alert with Active Protection – (not available on earlier models) Turn this feature ON to enable active protection. This allows the thermostat to identify fault codes sent by the Comfort Alert module when compressor damage is possible and react to those codes by turning the compressor off. Fault codes from the Comfort Alert module will flash on the thermostat. (Refer to Comfort Alert Codes in Troubleshooting section.) If a Comfort Alert module is not connected, or to disable active protection, turn this feature OFF. If a Comfort Alert module is connected and this feature is turned OFF, the thermostat will still receive and flash the fault codes from the Comfort Alert module, but the active protection will not be enabled to protect the compressor. 23. Heat Temperature Limit Range – This feature adjusts the highest setpoint temperature for heat. The default setting is 99°F. It can be changed to a setting between 62°F and 98°F. The "temperature limit" icon will be displayed to the left of your setpoint temperature when using this feature. The "temperature limit" icon will flash if an attempt is made to adjust the temperature beyond the range selected. 24. Cool Temperature Limit Range – This feature adjusts the lowest setpoint temperature for cool. The default setting is 45°F. It can be changed to a setting between 46°F and 82°F. The "temperature limit" icon will be displayed to the left of your setpoint temperature when using this feature. The "temperature limit" icon will flash if an attempt is made to adjust the temperature beyond the range selected. 25 & 26. Keypad Lockout – This step allows you to select the type of lockout or limited range security required. If no to lockout or limited range security is required, press advance the menu. Three security settings are available in this menu item. or keys to select the lockout desired. Use the Lockout selections are: "Keypad Lockout and L" = Total Lockout. Total Lockout locks all keys. "Keypad Lockout and P" = Partial Lockout. Partial Lockor keys to operate within your out allows only the set temperature limits. "Temperature Limit/Keypad Lockout" prevents changing the temperature limits in the Configuration Menu. After the type of lockout is selected, press . Keypad Lockout Combination Number Selection Display will read "000" "Keypad Lockout". INSTALLER/CONFIGURATION MENU Skip this step and continue through the remainder of the configuration menu if you require an Air Filter Change out indicator or Humidifier Pad Change out indicator by key to advance. pressing the Return to this point when you are ready to start your selected lock-out and continue by: or keys to select your keypad lockout Pressing combination number. Note: "000" is not a valid combination choice. Record the number you select for future use. to exit the menu. The security feature you select Press will start in 10 seconds. The system key will remain active for 10 seconds to allow setting Heat, Off, Cool or Auto. To unlock the keypad, press Menu, then press Installer Config. Display will show "000" and keypad lock. Enter the code used to lock the keypad and press . 27 & 28. Select Fast Second Stage, ON or OFF – Not available if configured for SS1. Selecting FA ON forces is additional heat stages to come on quickly when used to raise the temperature a few degrees above the room. Select this setting if you want the heat to increase quickly when you manually raise the temperature. Selecting FA OFF allows the thermostat to calculate an optimal time to bring on additional stages of heat. When is used to raise the setting above the room temthe perature additional heat stages may come on very quickly or very slowly (up to 30 minutes later) depending on recent system performance. Select this setting if you do not require the additional heat stages to come on quickly when you manually raise the setting and want to allow the thermostat to stage based on recent system performance. The Fast Cool feature operates the cooling stages in the same manner as Fast Heat, On or Off when the temperature is lowered below the room setting. 29. Select Remote Temperature Sensor Enabled – ON enables a remote sensor connected to thermostat and displays the sensor temperature in the clock digits. OFF (default) indicates no remote sensor connected or enabled. 30. Select Remote Sensor as Indoor or Outdoor – If 30 is enabled, select the remote to be Remote In (Indoor, F145-1328) or Outdoor Remote (Outdoor, F145-1378). Default is Remote In. 31. Select Local Sensor Disable – If 31 is selected Indoor, the thermostat Local Sensor can be disabled so the displayed temperature will be from the Remote Sensor. Default is On LS. To disable the Local Sensor, change selection to OFF LS. 32. Select Dual Fuel Feature (dF) – This feature is applicable only in heat pump modes (HP1, HP2). Enables (On) or disables (Off) dual fuel feature of thermostat. 33. Select Dual Fuel Temperature – With dF selected On and outdoor remote sensor available, select the outdoor temperature the thermostat will use to determine when to switch to gas heat and shut down the compressor. When the outdoor temperature falls below the selected temperature the gas heat will begin. Default is 35°, but can be set in the range of -5 to 50°. A lower setting will delay the start of gas heat allowing cooler temperature in the home. 34. Select Dual Fuel Setting – With DF selected On and no outdoor sensor, select the dF setting from 01-09. Factory default is 05. The dF setting influences when second stage comes on. The factory default creates a separation of approximately 1°F between stages. Increasing the setting decreases the separation between stages. Decreasing the value increases stage separation. This adjustment allows a small change in the operation of your heat pump system versus your auxiliary system relative to the thermostat adjustment. The higher the number the sooner the auxiliary stage energizes for better comfort. The lower the number the longer period of time before auxiliary is energized for more economy. Note: This setting is not minutes or degrees. It is numeric setting that will influence the internal thermostat calculation for staging. 35. Select Compressor Delay (Cd) – After the auxiliary heat is turned on, the compressor(s) shut down is delayed for the time selected (in seconds). This delay is factory set to 60, but can be set in the range of 0 to 99. 36. Select Auxiliary Off (AO) – Applicable with HP1 or HP2 selected with outdoor sensor. Select the temperature that will inhibit the auxiliary heating stage. As long as the outdoor temperature is above the selected temperature, the auxiliary heat will not turn on. The default setting is 80°(disabled), but can be set in the range of -5 ° to 79°. Thermostat will not allow a setting at or below the (dF) dual fuel setting. If indoor temperature drops below 45° because of a possible heat pump malfunction, the thermostat will turn off the pump and switch to Auxiliary heat. "Call for Service" will display on screen. There are two ways the thermostat will return to normal heat pump operation: • Press any key to retry the pump and erase the "call for service icon. • When setpoint is achieved on Auxiliary, system will return to heat pump operation on next call for heat. 37. Select Programmable Blower Balance Point (bP) – Applicable with HP1 or HP2 selected, dF On with outdoor sensor. Requires DHM connection from thermostat to heat pump system. This feature de-energizes the DHM terminal to operate the blower at a slower speed for first stage heat when the outdoor temperature is below the temperature selected. This circulates warmer air than the higher fan speed. The default is 80° (disabled), but can be set from 20° to 79°. Select an outdoor temperature where the air coming out of the ducts begins to feel cool and the thermostat will lower the fan speed to circulate warmer air. 38. Humidity Display (Hd) – Selecting HD On enables the display to alternately show the current time and the humidity. If HD is selected OFF, the display will not show the humidity. (See page 10 for Humidity setpoint range) 39. Adjustable Humidity Display – The display will show the ambient humidity and 00 (default). The setting can be changed from -20 and LO to 20 and HI. The displayed humidity will change as the offset is changed. In Run mode, the displayed humidity will be the ambient humidity adjusted by the setting selected. 40. Auto Humidity Reduction (HR) – This feature automatically lowers humidity setting when the outside temperature drops to prevent the interior windows/walls from reaching the dew point where water condenses on surfaces. This feature default is OFF. It can be changed to select LO (low humidity reduction) or HI. To achieve automatic humidity reduction, the thermostat lowers the humidity when furnace cycles are long. When the outside temperature rises, it increases humidity. "LO" indicates a low amount of humidity reduction. 41. Automatic Humidification (AH) – This feature if enabled allows for humidification independent of a call for heating – useful in arid climates where addition humidification in heating and/or cooling is desired. If enabled, will energize the humidifier and circulator blower (“G” terminal and the 9 INSTALLER/CONFIGURATION MENU “HM” terminal) if the actual humidity is below the humidity set point. The display indicates AH. Pressing the key will cycle the display from OFF to H (feature enabled in Heat mode) to C (feature enabled in Cool mode) to A (feature enabled to Auto mode) and back to OFF. 42. Cycle Humidifier (CH) – This feature provides an option that reduces the water usage by up to 50% when a flow-through humidifier is controlled by the thermostat. It is recommended for use on flow-through humidifiers only. The display indicates CH (Cycle Humidifier) with the deor keys will toggle fault indicating OFF. Pressing the the display from OFF to On and back to OFF. When CH is enabled, the humidifier will cycle to turn off for 10 minutes after it has run for 10 minutes. The blower and/or furnace will continue to run during the humidifier off period. 43. Programmable Dehumidification Optimal Comfort Mode (OC) or Optimal Dehumidification (Od) – This item can be selected to OC (Optimal Comfort mode), Od (Optimal Dehumidification), or OFF. When Optimal Comfort (OC) is enabled, this feature automatically reduces indoor humidity with a call for Cooling if humidity is 2% above humidity setpoint. Humidity is set by pressing the Humidity key when in the appropriate mode, in this case or keys to set desired Cooling, and pressing the humidity (range 40% to 95%) level followed by pressing Humidity key again. This dehumidification feature uses less energy by maintaining temperature and dehumidifying only when a call for Cooling is required. Optimal Dehumidification (Od) when enabled, this feature automatically reduces indoor humidity with a call for Cooling if humidity is 2% above setting. Humidity is set by pressing the HUMIDITY key when in the appropriate mode, in or keys to set this case Cooling, and pressing the desired humidity level followed by pressing Humidity key again. This dehumidification feature may use more energy by making dehumidification a priority initiating a call for cooling if humidity is 2% above desired setting. This feature may also over-cool the condition space by up to 3 degrees to achieve the desired humidity level. (Note: Both dehumidification modes operate in Cooling mode only with a call for cooling) 44 & 45. Change UV Lamp – This feature allows the thermostat to display the words "Change UV Lamp" (Call for Service of UV bulb) after a set time of UV bulb operation. This is a reminder to maintain your UV system at optimum level of operation. When enabled, the factory set interval for "Change UV Lamp" to be displayed is 350 days of UV bulb operation and can be adjusted in 25 day increments. This should be adjusted with respect to the bulb’s recommended maintenance schedule. When "Change UV Lamp" is displayed, you can clear it by pressing Clean Display. 46 & 47. Change Humidifier Pad – This feature allows the thermostat to display the words "Change Pad" after a set time of humidifier operation. This is a reminder to maintain or clean your humidifier. The factory set interval for "Change Pad" to be displayed is 100 hours of humidifier operation. This should be adjusted with respect to the humidifier’s recommended maintenance schedule. When "Change Pad" is displayed, you can clear it by pressing Clean Display. 48 & 49. Select Change Filter Run Time – This feature allows thermostat to display "Change Filter" after a set time of blower operation. This is a reminder to change or clean your air filter. This time can be set from 25 to 1975 hours in 25 hour increments. A selection of OFF will cancel this feature. When "Change Filter" is displayed, you can clear it by pressing Clean Display. In a typical application, 200 hours of run time is approximately 30 days. OPERATING YOUR THERMOSTAT Check Thermostat Operation Heating/Humidifier NOTE 1. Press SYSTEM key to select HEAT. If the auxiliary heating system has a standing pilot, be sure to light it. To prevent static discharge problems, touch side of thermostat to release static build-up before touching any keys. 2. Press to adjust thermostat setting to 1° above the room temperature. The heat pump system should begin to operate. The display should show "System On". However, if the system configuration is set to HP1 or HP2 and setpoint temperature display is flashing, the 5 minute compressor lockout feature is operating (see Configuration menu, item 11). If at any time during testing your system does not operate properly, contact a qualified service person. Fan Operation If your system does not have a G terminal connection, skip to Heating System. 1. Turn on power to system. 2. Press fan key to ON position. The blower should begin to operate. 3. Press fan key to AUTO position. The blower should stop immediately. ! CAUTION Do not allow the compressor to run unless the compressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes. 10 3. Adjust temperature setting to 3° above room temperature. If your system configuration is set at MS2, HP1 or HP2, the auxiliary heat system should begin to operate and the display will show "System On +2". 4. Press to adjust the thermostat below room temperature. The heating system should stop operating. To check the humidifier when System On appears and the heating system is running press the HUMIDITY* button once. Press to adjust the humidity 2% or more above the room humidity level setpoint range. (Humidity setpoint can be adjusted from 5 to 50%.) Hum On will appear indicating it is calling for the humidifier. *Note: If Auto Schedule is displayed instead of Humidity, Auto Schedule must be turned off in the Configuration Menu. OPERATING YOUR THERMOSTAT Emergency Mode Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning. Emergency Heat (System EM Position) bypasses the Heat Pump to use the heat source wired to terminal W/E, W2 on the thermostat. EM is typically used when compressor operation is not desired, or you prefer back-up heat only. Tip: Running the fan more frequently will increase your energy consumption. Most systems use a 1/2 or 1/3 HP electric motor to power the fan. Applies only to Heat Pump Systems 1. Press SYSTEM key to select EM. “EM Heat Mode” will flash on the display. 2. Press to adjust thermostat setting above room temperature. The Emergency heating system will begin to operate. The display will show “System On” flashing “EM Heat Mode” and “Heat” to indicate that the Emergency system is operating. 3. Adjust temperature setting to 3° above room temperature. Any additional stages of auxiliary heat should begin to operate and the display will show "System On +2". 4. Press to adjust the thermostat below room temperature. The heating system should stop operating. ! CAUTION To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system. Cooling/Dehumidifier 1. Press SYSTEM to select "Cool". to adjust the thermostat setting below room tem2. Press perature. The blower should come on immediately on high speed, followed by cold air circulation. The display should show "System On". If the setpoint temperature display is flashing, the compressor lockout feature is operating (see Configuration menu, item 11). 3. Adjust temperature setting to 3° below room temperature. The second stage cooling should begin to operate and the display should show "System On +2". 4. Press to adjust the temperature setting above room temperature. The cooling system should stop operating. To check the dehumidifier when System On appears and the cooling system is running press HUMIDITY* button once. Press to adjust the humidity 2% or more below the room humidity level setpoint range. DeHum On will appear indicating it is calling for the dehumidification. If the room humidity is lower than the adjustment range, press to 40% and hold it for four seconds. This will force the DeHum On for one complete cooling cycle to test the dehumidification equipment. After adjusting the humidity setting the display will return to temperature in approximately 10 seconds. To switch the display back to temperature immediately after adjusting humidity setting press HUMIDITY again. *Note: If Auto Schedule is displayed instead of Humidity, Auto Schedule must be turned off in the Configuration Menu. Choose the System Setting (Cool, Off, Heat, Em, Auto) Press the SYSTEM key to select: Cool: Thermostat controls only the cooling system. Off: Heating and Cooling systems are off. Heat: Thermostat controls only the heating system. Em: Setting is available only when the thermostat is configured in HP1 or HP2 mode. Auto: Auto Changeover is used in areas where both heating and cooling may be required on the same day. AUTO allows the thermostat to automatically select heating or cooling depending on the indoor temperature and the selected heat and cool temperatures. When using AUTO, be sure to set the Cooling temperatures more than 1° Fahrenheit higher than the heating temperature. Manual Operation for Non-Programmable Mode Press the SYSTEM key to select "Heat" or "Cool" and use the keys to adjust the temperature to your desired setting. After selecting your desired settings you can also press the SYSTEM key to select AUTO to allow the thermostat to automatically change between "Heat" and "Cool". Manual Operation (Bypassing the Program) Programmable Mode Manual operation will bypass the program and allow you to adjust the temperature as you desire. The temperature you or to set in Hold will be maintained indefinitely. Press adjust the temperature. The HOLD key will appear. Press the HOLD key. "Hold At" will appear next to the setpoint temperature and the thermostat will maintain the new setpoint temperature until Run Schedule is pressed to resume program operation. Program Override (Temporary Override) Press or keys to adjust the temperature. This will override the temperature setting for a (default) four hour override period. The override period can be shortened by pressing or lengthened by pressing . Program Override period can range from 15 minutes to 7 days. Example: If you turn up the heat during the morning program, it will be automatically lowered later, when the temporary hold period ends. To cancel the temporary setting at any time and return to the program, press Run Schedule. If the SYSTEM key is pressed to select AUTO the thermostat will change to "Heat" or "Cool", whichever ran last. If it switches to "Heat", but you want "Cool", or it changes to "Cool", but you want "Heat", press both keys simultaneously to change to the other mode. Choose the Fan Setting (Auto or On) Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on. 11 PROGRAMMING Set Current Time and Day 1. Press Menu key to enter installer menu. Then press Set Time once to indicate hour & AM or PM designation in clock display. or touch key until you 2. Press and hold either the reach the correct hour and AM or PM designation. 3. Press Set Time again to display minutes only in clock display. 4. Press and hold either the reach the correct minutes. or touch keys until you 5. Press Set Time once again to display year. 6. Press either the correct year. or touch key until you reach the 7. Press Set Time once again to display month. 8. Press either the correct month. or touch key until you reach the Fill in the blank schedule on the next page then: Enter the Heating Program 1. Press the Menu key and then press Set Schedule. Press SYSTEM key to select "Heat" in the system switch area indicating the active mode being programmed. You can switch to the other mode by pressing the system switch at any time. 2. The top of the display will show the day(s) being programmed. The time and set at temperature are also displayed. "Morning" will also be displayed to indicate the period. or key to change the temperature to your 3. Press selected temperature for the 1st heating period (Morning). or key to adjust the start time for period. 4. Press The time will change in 15 minute increments. 5. Press FAN to select Auto or Prog. 9. Press Set Time once again to display date of the month along with day of the week at top row (which is automatic). 6. After you have set the time and the temperature for the period to begin, press Set Schedule to advance to the next program period. or touch key until you 10. Press and hold either the reach the correct day of the month and day of the week displayed at the top row. 7. Repeat steps 2 through 6 until all of the program times and temperatures are set for all program periods on that day. 11. Press Run Schedule once or twice to remove the key. Now the display will show the correct time and room temperature. 8. Press "Advance Day" to change to the next day and repeat steps 2 through 8. Automatic Daylight Saving Calculation The Real Time Clock will adjust automatically for daylight savings time, in the following manner: Increment one hour at 2 AM on the second Sunday of March and decrement one hour at 2 AM on the first Sunday of November. The daylight saving feature can be enabled or disabled in installer configuration menu. Default is DS ON (enabled). After entering installer configuration mode, momentarily press touch key until the display indicates dS (in actual temand perature digits) and on (default – in clock digits). keys will toggle display and operation from on to OFF. Programming Tip: Copy Program 9. When programming is complete and all of the times and temperatures match your desired heating schedule, press Run Schedule. The thermostat will now run your program. Enter the Cooling Program 1. Press the SYSTEM key until the "Cool" icon appears. 2. Follow Enter Heating Program instructions for entering cooling times and temperatures. Automatic Schedule Auto Schedule Heat is a fast way to program all the heating temperatures during the day to a comfortable temperature and then lower the temperature 6° at night. Auto Schedule Cool will program all of the cooling time periods to the same temperature. When programming your thermostat, you may copy the program from one day to another day or group of days using the Copy key. In 7 day programming mode, a day can be copied to another day or all six other days. In 5+1+1 day programming mode the weekday (Mon – Fri) program can be copied into Sat and Sun or either Sat or Sun. Note: Auto Schedule is available only when the thermostat is first powered on, after the thermostat has been reset, or anytime you turn AS on in the Configuration Menu (item 17 AS Heat or 18 AS Cool). After use in heating and cooling, Auto Schedule on the display will change to Humidity. To copy a program from one day to another: 1. In Heat mode, press Auto Schedule once. 1. In Set Schedule mode, enter the program for the day or select the day you wish to copy by pressing Advance Day. 2. Press Copy. The display will show “Copy” next to the SYSTEM key and the day of the week that will be copied. 3. Press Advance Day. The day being copied will be indicated and the other days will be flashing. 4. If you wish to copy to all days skip to next step or press Advance Day until the day you wish to copy to is flashing. 5. Press Copy. “Copy” will disappear, the day you copied from will disappear and the day(s) you copied to will be on. 6. If you wish to copy this same program into other days, press Copy and repeat steps 3, 4 and 5. 7. Press Run Schedule to return to normal operation. 12 Heating Example: 2. Press or to select a comfortable day time temperature (example 72°). 3. Press Auto Schedule again. Your thermostat is now programmed for 72° from 6:30 AM until 10:30 PM at 72°. At 10:30 PM, your thermostat will set back 6° to 66°. Your heating program for each day of the week will look like this: 6:30 8:00 5:00 10:30 72° 72° 72° 66° PROGRAMMING Programmable Fan Option Cooling Example: 1. In cool, press Auto Schedule once. or to select a comfortable cooling tempera2. Press ture (example 75°). 3. Press Auto Schedule again. Your thermostat is now programmed for 75° for all cooling time periods. Your cooling program for each day of the week will look like this: 6:30 8:00 5:00 10:30 75° 75° 75° 75° In the Set Schedule mode, the Fan key is used to select the fan operation during a program period. The default state of the Fan key is FAN Auto (fan runs during a call for cool but not on a call for heat). It can be changed to FAN Prog (fan runs during a program period). Each press of the FAN key will change the mode of the fan between Auto and Prog. In the Run mode, when a program period that has FAN Prog begins, the fan will turn on and stay on during the complete period. The display will show FAN On Prog. Pressing the FAN key will change FAN On Prog to On (fan running continuously) or Auto. To return to FAN On Prog, press Run Schedule. Energy Saving Factory Pre-Program The 1F95-1291 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the RUN key. The table below shows the factory set heating and cooling schedule for all days of the week. * Wake Up (Morning) Leave For Work (Day) * Return Home (Evening) Go To Bed (Night) Heating Program 6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F Cooling Program 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F * You can eliminate these two program periods in the configuration menu (reference #5) if the building is occupied all day. Day period will change to 6:00 AM and 70° and can be programmed as required. Planning Your Program – Important The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures. The 1F95-1291 comes configured for 7 day programming and can also be configured for 5+1+1 programming (see configuration section). Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your own times and temperatures directly below the factory times and temperatures. If you are re-programming a 7 day schedule, fill in all lines with the times and temperatures you want. Keep the following guidelines in mind when planning your program. • In Heating, lower temperatures will save energy. • In Cooling, higher temperatures will save energy. • If you plan on using Auto Changeover, do not program the heating temperature higher than the cooling temperature. 13 PROGRAMMING Worksheet for Re-Programming 5+1+1 and 7 Day Program Heating Program MON Wake Up (Morning) Fan Leave For Work (Day) Fan Return Home (Evening) Fan Go To Bed (Night) Fan 6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto 6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto 6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto TUE WED THU FRI SAT SUN Cooling Program MON Wake Up (Morning) Fan Leave For Work (Day) Fan Return Home (Evening) Fan Go To Bed (Night) Fan 6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto 6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto 6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto TUE WED THU FRI SAT SUN Wired Remote Temperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 feet). Terminals +, S and - on the terminal block allow connection of the remote sensor. The thermostat must have 24 VAC Common connection to terminal C for the remote sensor to operate. The remote sensor can be enabled or disabled in the Installer/Configuration menu, item 29. When remote sensor, Remote, is selected Off (factory default), no remote sensor is enabled. When remote sensor is selected On, the next step is to select the remote as indoor, Remote In, or outdoor, Outdoor Remote. If the remote is selected as Remote In, an additional step will be to select if the 14 temperature shown on the display will be from the thermostat, LS On, or the remote sensor LS Off. In normal operation, when a remote sensor is enabled the time digits of the display will alternate between the time and the remote temperature for three seconds each. Above the remote temperature will be Remote, for indoor sensor or Outdoor Remote, for outdoor sensor. If the remote sensor is an indoor sensor and the local display has been disabled, the temperature displayed as the room temperature will be the remote sensor temperature. Sensing Range: Outdoor temperature range is -40oF to 140oF Indoor temperature range is 32oF to 99 oF PROGRAMMING Averaging or Weighting Remote Sensors Dual Fuel Temperature Setpoint The thermostat will weight or average the temperature of the indoor remote sensor with the local sensor in the thermostat for each program period. The averaging will be active only when the local sensor and the indoor remote sensor are both functional and enabled in the Installer/Configuration menu. When the thermostat is configured for Heat Pump mode and the Dual Fuel feature is selected on, the thermostat can monitor the outside temperature using remote sensor F145-1378 or use software logic to determine when to switch to gas heat and shut down the compressor. This eliminates the need for a fossil fuel kit. When the thermostat is in the Set Schedule mode, the weight of the indoor sensor will be shown in the current temperature digits of the display. The weight will show as A2 (average and default), H4 (high) or L1 (low). Pressing the and keys at the same time will change the weight for the program period. The weight of the thermostat sensor is fixed. In normal operation of the thermostat, the current temperature displayed will be the weighted average of the local sensor and the remote sensor using the formula (local sensor weight x local sensor temperature) + (remote sensor weight x remote sensor temperature) / (local sensor weight + remote sensor weight). Example: Local sensor temperature is 80° and the remote sensor is 70°. If weight is selected H4, the averaged temperature of 72° will be displayed. (1 x 80) + (4 x 70) / 5 = 72° If weight is selected A2, the average temperature of 73° will be displayed. (1 x 80) + (2 x 70) / 3 = 73.3° If weight is selected L1, the average temperature of 75° will be displayed. (1 x 80) + (1 x 70) / 2 = 75° The example shows that the weight selected would prioritize the overall averaged temperature between the two sensors. The high weight selection caused the remote sensor to have a higher influence in the calculated temperature average than the local sensor and the low weight selection caused the remote sensor to have less influence. The user selectable temperature is called the dual fuel temperature setpoint, dF and is set in the Installer/Configuration menu, items 33 or 34. With outdoor remote sensor installed and enabled, the dual fuel temperature setpoint (menu item 33) can be set to a temperature of -5° through 50°. When outdoor remote sensor is not installed, a software logic based dual fuel number (menu item 34) from 01 to 09 can be selected. A higher temperature or dual fuel setting will provide a smaller stage separation between the heat pump and Aux to give more comfort. A lower temperature or number will provide a larger stage separation for more economy. is After the dual fuel temperature setpoint is set and pressed, a delay, Cd, can be set for compressor shutdown after the auxiliary stage is energized. This delay can be set from 0 seconds to 99 seconds to minimize the time that the system may blow cooler air until the alternate source of heat comes on. Default setting for delay is 60. When setting the or keys are held depressed, the setpoint delay, if the will increase or decrease at the rate of one degree every half second for the first three seconds and double the speed after three seconds. Blower Balance Point for Heating Requires DHM connection from thermostat to heat pump system. Air to air heat pumps use a fast fan speed to circulate warm air for first stage heating. As outdoor temperatures drop, the heat pump produces less heat and a high fan speed makes the air from the ducts feel cooler. Blower Balance Point allows you to select an outdoor temperature to slow the fan speed so the air from the duct feels warmer. Select an outdoor temperature where the air from the ducts starts to feel cool (Installer Configuration Menu item 37). When the outdoor temperature drops to the selected temperature, the thermostat will slow the fan speed so the outlet air feels warmer. TROUBLESHOOTING Comfort Alert Codes The Comfort Alert diagnostics product monitors the air conditioning outdoor systems with single phase Copeland Scroll compressors. Abnormal system and electrical conditions are indicated by flashing ALERT codes on the yellow LED on the Comfort Alert module. The flash codes are transmitted to the thermostat by the Comfort Alert Thermostat interface module. The Comfort Alert compatible thermostat displays “Call For Service” that flashes at the same rate as the yellow LED on the Comfort Alert module. 1 Flash 2 Flashs 3 Flashs 4 Flashs 5 Flashs 6 Flashs 7 Flashs 8 Flashs 9 Flashs Comfort Alert Codes Long run time System pressure trip Short cycling Locked rotor Open circuit Open start circuit Open run circuit Welded Contactor Low voltage 15 TROUBLESHOOTING Reset Operation Note: If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermostat by removing the thermostat from the wall plate and removing batteries for 2 minutes. After two minutes, replace the batteries and replace thermostat on wall plate. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase. Symptom Possible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker. 2. Furnace power switch to OFF. 3. Furnace blower compartment door or panel loose or not properly installed. 4. Loose connection to thermostat or system. 1. Pilot light not lit. 2. Furnace Lock-Out Condition. Heat may also be intermittent. Replace fuse or reset breaker. Turn switch to ON. Replace door panel in proper position to engage safety interlock or door switch. Tighten connections. Re-light pilot. Many furnaces have safety devices that shut down when a lock-out condition occurs. If the heat works intermittently contact the furnace manufacturer or local HVAC service person for assistance. Diagnostic: Set SYSTEM Switch to HEAT and raise the setpoint above room temperature. Within a few seconds the thermostat should make a soft click sound. This sound usually indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed above. If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly. Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling. Check each wire connection to verify they are not shorted or touching together. No bare wire should stick out from under terminal block. Try resetting the thermostat as described above. If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat/Cool system for correct operation. If the system operates correctly, replace the thermostat. The thermometer can be adjusted +/- 4 degrees. See Temperature Display Adjustment in the Configuration Menu section. Digital thermostats provide precise control and cycle faster than older mechanical models. The system turns on and off more frequently but runs for a shorter time so there is no increase in energy use. If you would like an increased cycle time, choose SL for slow cycle in the Configuration menu, step 7 (heat) or 8 (cool). If an acceptable cycle rate is not achieved, contact a local HVAC service person for additional suggestions. No Heat 3. Heating system requires service or thermostat requires replacement. No Cool 1. Cooling system requires service or thermostat requires replacement. Heat, Cool or Fan Runs Constantly 1. Possible short in wiring. 2. Possible short in thermostat. 3. Possible short in heat/cool/fan system. 4. FAN Switch set to Fan ON. Thermostat Setting & Thermostat Thermometer Disagree Furnace (Air Conditioner) Cycles Too Fast or Too Slow (narrow or wide temperature swing) 1. Thermostat thermometer setting requires adjustment. 1. The location of the thermostat and/or the size of the Heating System may be influencing the cycle rate. Forgot Keypad Lockout Code Blank display any or keypad not responding Thermostat does not have Menu Screen Numbers 1. Voltage Spike or static discharge 1. Earlier version of thermostat Press the menu key (key will disappear) and hold in for 20 seconds. This unlocks the thermostat. Use the Reset Operation shown above. To access the earlier version instruction sheet (37-6914E) go to www.white-rodgers.com, enter 1F95-1291 in Model Number Search Homeowner Help Line: 1-800-284-2925 White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. www.white-rodgers.com www.emersonclimate.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:b38d73a5-3339-4b08-b7b7-0aeb69b419ef Original Document ID : adobe:docid:indd:24efc652-cdc4-11dc-9f21-9a124a567fa8 Document ID : xmp.id:5A97A06A58C2E211A1A3EE1EB9CCBFA7 Rendition Class : proof:pdf Version ID : 1 Derived From Instance ID : xmp.iid:5997A06A58C2E211A1A3EE1EB9CCBFA7 Derived From Document ID : xmp.did:6E56C255325FE111B242C9E2FAD76A13 Derived From Original Document ID: adobe:docid:indd:24efc652-cdc4-11dc-9f21-9a124a567fa8 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2013:05:22 04:53:24+08:00 Create Date : 2013:05:22 04:53:24+08:00 Modify Date : 2013:07:25 07:18:51-05:00 Metadata Date : 2013:07:25 07:18:51-05:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Title : 1F95-1291_37-7313B.indd Producer : Adobe PDF Library 10.0.1 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Page Count : 16 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools