Enlighted PC-01-20 Intelligent Energy Sensor for Smart Networked Energy Saving Lighting Systems User Manual PowerPoint Presentation

Enlighted, Inc. Intelligent Energy Sensor for Smart Networked Energy Saving Lighting Systems PowerPoint Presentation

Users Manual

Download: Enlighted PC-01-20 Intelligent Energy Sensor for Smart Networked Energy Saving Lighting Systems User Manual PowerPoint Presentation
Mirror Download [FCC.gov]Enlighted PC-01-20 Intelligent Energy Sensor for Smart Networked Energy Saving Lighting Systems User Manual PowerPoint Presentation
Document ID2581518
Application IDGkD0D9Uj1Q0n33z/+zhtwg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.63kB (370315 bits)
Date Submitted2015-04-10 00:00:00
Date Available2015-04-20 00:00:00
Creation Date2015-03-25 14:47:33
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2015-03-25 14:47:38
Document TitlePowerPoint Presentation
Document CreatorAcrobat PDFMaker 11 for PowerPoint
Document Author: Prachi Mokashi;David Perkins

FCC and Industry Canada Compliance Information
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
USA
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
• this device may not cause harmful interference, AND
• this device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by Enlighted Inc.
could void the user's authority to operate the equipment.
Canada
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
• this device may not cause harmful interference, AND
• this device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by Enlighted Inc.
could void the user's authority to operate the equipment.
Copyright © 2014 Enlighted Inc. All rights reserved.
All other brand or product names are trademarks of
their respective companies or organizations.
Plug Load Controller
Model PC-01-20
Installation Instructions
Technical Support
For questions regarding the installation or operation of
this product, contact Enlighted
Technical Support: support@enlightedinc.com
Company Contact Information
Location: 930 Benecia Ave, Sunnyvale, CA 94085
Phone: +1.650.964.1094
Web: enlightedinc.com
CA Contractor’s License: CCL# 980903
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes:
• l'appareil ne doit pas produire de brouillage, ET
• l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
Figure 1: Plug Load Controller, Locknut, and Sticker
Shipped Components
• Plug load controller (and ½ inch locknut)
CE
• MAC address sticker
This device complies with the essential requirements and other
relevant requirements of the R&TTE Directive (1999/5/EC). The
product is compliant with the following standards and/or other
normative documents. EN 62479, ETSI EN 301, EN 300
• The equipment is Class 1 radio equipment which can be placed
on the market and be put into service without restrictions in
accordance with article 1(3) of Commission Decision 2000/299/EC
(Version July 2014).
Tools You May Need
• Wire stripper
Supplies You May Need
• Wire nuts (or connectors)
• Junction box (j-box)
• 2 Conductor plus ground 12 AWG solid wire cable
Model: PC-01-20
FCC ID: AQQ-PC-01-20
Industry Canada: 10138A-PC0120
• 3 Conductor plus ground 12 AWG solid wire cable
• Clamps
Page 5
Page 6
93-01142-01 Rev02
Page 1
Cautionary Suggestions
Troubleshooting
Installation Steps (Continued)
• Installation and maintenance must be performed by
Step
qualified electrician.
• Installations and maintenance must be performed in
accordance with local, state, and national electrical codes
and requirements.
Installation Steps
Step Description
Problem
Description
Install the receptacle in the wall box
10
Attach a receptacle faceplate that distinguishes the
controlled outlet.
11
Attach the included MAC address sticker on the
faceplate.
Solution
LED is not on when
the device is
powered
1) Check to see that power is present
from the circuit panel.
2) Check the wiring, if LED does not
come on, then replace the
device.
J-box Install (see Figure 2)
Punch out a ½ inch knock out from the j-box and
insert the threaded end of the plug load controller.
Secure the plug load controller to the j-box with the
supplied locknut.
(Main Feed) Feed the j-box with (3) 12 AWG
conductors. (Hot, Neutral, and Ground)
Connect the j-box with (4) 12 AWG conductors that
run from the j-box to the receptacle wall box.
(Hot, Switched Hot, Neutral, and Ground)
Using wire nuts (or wire connectors):
a) Connect the hot wire from the main feed to the
black wire of the plug load controller.
b) Connect the neutral wire from the main feed to
the white wire of the plug load controller and the
neutral wire that feeds through to the receptacle.
c) Connect the red wire of the plug load controller
to the switched hot wire that feeds through to the
receptacle.
d) Connect the blue wire of the plug load controller
to the hot wire that feeds through to the
receptacle.
e) Connect all ground wires to the j-box.
Switched Neutral
Hot
Hot
Ground
Main feed:
• Hot
• Neutral
• Ground
Receptacle feed:
•
•
•
•
Hot
Switched Hot
Neutral
Ground
Figure 2: J-box with plug load controller, showing main
feed and wiring to receptacle.
Receptacle Install (see Figure 4)
Break the connection on the “hot side” of the
receptacle between the two outlets.
Connect the neutral wire to the neutral connection
on the receptacle.
Connect the switched hot wire to the hot side of the
“controlled outlet”.
Connect the hot wire to the hot connection of the
“uncontrolled outlet” (always powered).
Page 2
Figure 4: Receptacle wiring
Figure 3: Wiring Diagram
Page 3
Page 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Prachi Mokashi;David Perkins
Create Date                     : 2015:03:25 14:47:33-07:00
Modify Date                     : 2015:03:25 14:47:38-07:00
Language                        : EN-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2015:03:25 14:47:38-07:00
Creator Tool                    : Acrobat PDFMaker 11 for PowerPoint
Document ID                     : uuid:320675ee-29da-4367-a9c7-9227b866c5ad
Instance ID                     : uuid:886fb710-8a76-4864-827f-32faaf896634
Format                          : application/pdf
Title                           : PowerPoint Presentation
Creator                         : Prachi Mokashi;David Perkins
Producer                        : Adobe PDF Library 11.0
Tag Template ID                 : TC038954999991
Content Type Id                 : 0x010100C18F4B2A42872D4598EAF6FD0E8C634D
Page Layout                     : SinglePage
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: AQQ-PC-01-20

Navigation menu