GE Power Electronics BLST-SP765 Electronic Ballast for Fluorescent Lamp User Manual User s Manual for 50W

GE Power Electronics (Shanghai) Co., Ltd. Electronic Ballast for Fluorescent Lamp User s Manual for 50W

User Manual

Electronic Ballast For Electrodeless Fluorescent Lamp
1Product code.
50W
SP765-Y01A AJA-LINEAGE-WJY-QB7C
2Outside characteristic.
The outside picture of Electronic Ballast For Electrodeless Fluorescent Lamp as below,
there are three wires at input port, L line is BrownN line is Blue, GND line is yellow and
green. There are two white wires at output port. The input wires connect to the power grid, and
the output wires connect to the Electrodeless Fluorescent Lamp.
Outside picture
Size
Size picture
3Electrical characteristic.
1) Input Voltage 100V-277V
2Input Rating Current
0.6/0.5/0.25/0.23A @100/120V/230V/277V--electrodeless lamp 50W
3Output Rating Current
0.5A (load, electrodeless lamp 50W)
4Output Rating Voltage
105V (load, electrodeless lamp 50W)
5Start Trigger Voltage
1450±100Vop (load, electrodeless lamp 50W)
6Output Frequency
230K±30kHz (load, electrodeless lamp 50W)
7Not load, removing lamp and load short protection
4Ambient temperature.
Generally the ballast is set up in the lamps and lanterns to use, the ambient temperature of
ballast is -40--60 in lamps and lanterns.
5. This device has been evaluated to comply with the requirements of FCC Part 18, UL935,
CAN/CSA C22.2 No.74-96, IEC61347-1, IEC61347-2-3, EN55015, EN61547, EN61000-3-2,
EN61000-3-3, GB19510.1-2004, GB19510.4-2005, GB17743-2007, GB17625.1-2003 and ROHS.
Warning: This product may cause interference to radio equipment and should not be installed
near maritime safety communications equipment or other critical navigation or communication
equipment operating between 0.45–30 MHz.