GE ADEW30LWQ1 User Manual DEHUMIDIFIER Manuals And Guides 1705233L

Use and Care Manual Dispatcher?RequestType=PDF&Name=49-7759 GE Appliances Literature Search Results

User Manual: GE ADEW30LWQ1 ADEW30LWQ1 GE DEHUMIDIFIER - Manuals and Guides View the owners manual for your GE DEHUMIDIFIER #ADEW30LWQ1. Home:Heating & Cooling Parts:GE Parts:GE DEHUMIDIFIER Manual

Open the PDF directly: View PDF PDF.
Page Count: 24

DownloadGE ADEW30LWQ1 User Manual  DEHUMIDIFIER - Manuals And Guides 1705233L
Open PDF In BrowserView PDF
DEHUMIDIFIER

SAFETY INFORMATION

. . . . . . . . .3

OPERATING INSTRUCTIONS

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
How the Dehumidifier Operates . . . . . . . . .5
Automatic Defrost . . . . . . . . . . . . . . . . . . . . .5
Choosing a Location . . . . . . . . . . . . . . . . . . .5
Removing Collected Water . . . . . . . . . . . . .6
Water Level . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Bucket Operation . . . . . . . . . . . . . . . . . . . . . .6

OWNER’S MANUAL
ADEW30
ADEW50
ADEW70

ENGLISH/ESPAÑOL

CARE AND CLEANING

Grille and Case . . . . . . . . . . . . . . . . . . . . . . . .7
Water Bucket . . . . . . . . . . . . . . . . . . . . . . . . .7
Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

TROUBLESHOOTING TIPS. . . . . . .8
CONSUMER SUPPORT

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Consumer Support . . . . . . . . . . . . . . . . . . . . 12

Write the model and serial
numbers here:
Model # _________________
Serial # _________________
You can find them on a label on
the back of the dehumidifier.

GE is a trademark of the General Electric Company. Manufactured under trademark license.

49-7759 10-16 GEA

THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.

2

49-7759

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING For your safety, the information in this manual must be followed to minimize the risk of
fire, electric shock or personal injury.
Ŷ8VHWKLVDSSOLDQFHRQO\IRULWVLQWHQGHGSXUSRVHDV
described in this Owner’s Manual.

Ŷ7XUQWKHGHKXPLGLILHU2))DQGXQSOXJLWEHIRUH
cleaning.

Ŷ7KLVGHKXPLGLILHUPXVWEHSURSHUO\LQVWDOOHGDQG
grounded as described in this manual before it is
used.

Ŷ*($SSOLDQFHVGRHVQRWVXSSRUWDQ\VHUYLFLQJRIWKH
dehumidifier. We strongly recommend that you do not
attempt to service the dehumidifier yourself.

Ŷ1HYHURSHUDWHWKLVGHKXPLGLILHULQDQDUHDWKDWLV
likely to accumulate standing water. If this condition
develops, for your safety disconnect the power supply
before stepping into the water.

Ŷ)RU\RXUVDIHW\GRQRWVWRUHRUXVHFRPEXVWLEOH
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.

Ŷ1HYHUXQSOXJ\RXUGHKXPLGLILHUE\SXOOLQJRQWKH
power cord. Always grip plug firmly and pull straight
out from the receptacle.
Ŷ5HSODFHLPPHGLDWHO\DOOHOHFWULFVHUYLFHFRUGV
that have become frayed or otherwise damaged.
A damaged power supply cord must be replaced
with a new power supply cord obtained from the
manufacturer and not repaired. Do not use a cord that
shows cracks or abrasion damage along its length or
at either the plug or connector end.
Ŷ,IWKHUHFHSWDFOHGRHVQRWPDWFKWKHSOXJWKH
receptacle must be changed out by a qualified
electrician

Ŷ$OOGHKXPLGLILHUVFRQWDLQUHIULJHUDQWVZKLFKXQGHU
federal law must be removed prior to product
disposal. If you are getting rid of an old product
with refrigerants, check with the company handling
disposal about what to do.

SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

Ŷ'RQRWXVHRXWGRRUV
Ŷ7KLVGHKXPLGLILHULVLQWHQGHGIRULQGRRUUHVLGHQWLDO
DSSOLFDWLRQVRQO\7KLVGHKXPLGLILHUVKRXOGQRWEH
used for commercial or industrial applications.
Ŷ7KHVH5$'HKXPLGLILHU6\VWHPVUHTXLUH
contractors and technicians to use tools, equipment
and safety standards approved for use with this
UHIULJHUDQW'2127XVHHTXLSPHQWFHUWLILHGIRU5
refrigerant only.

WARNING USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
Ŷ'2127XVHDQH[WHQVLRQFRUGZLWKWKLV'HKXPLGLILHU

Ŷ'2127XVHVXUJHSURWHFWRUVRUPXOWLRXWOHWDGDSWRUV
with this Dehumidifier.

HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
JURXQGSURQJIURPWKHSRZHUFRUG)RUSHUVRQDOVDIHW\
this appliance must be properly grounded.

Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.

'2127XVHDQDGDSWHUSOXJZLWKWKLVDSSOLDQFH

7KHGHKXPLGLILHUVKRXOGDOZD\VEHSOXJJHGLQWRLWVRZQ
individual electrical outlet, which has a voltage rating
matching the rating plate.

7KHSRZHUFRUGRIWKLVDSSOLDQFHLVHTXLSSHGZLWKD
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the possibility
of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.

7KLVSURYLGHVWKHEHVWSHUIRUPDQFHDQGDOVRSUHYHQWV
overloading house wiring circuits, which could cause a
fire hazard from overheated wires.

RECYCLING INFORMATION
For appliance recycling information please visit www.geappliances.com/recycling.

READ AND SAVE THESE INSTRUCTIONS
49-7759

3

OPERATING INSTRUCTIONS

Controls
Power On
indicator light

Clean the Filter
indicator light

High, Medium and
Low fan indicator
light

Continuous
Operation on
indicator light

4 hour or 2 hour
delay off
indicator lights

Empty

Nonstop
On

Power

Bucket Full light indicates
bucket needs to be emptied
or is not in place in the unit

Filter
Filter
Timer

-

+

Fan

Delay
Off

Hold 3 Sec To Rest

Controls
NOTE: When the bucket is full or removed, the controls
cannot be set.
1. Power Pad
Press to turn the dehumidifier on and off.
2. Filter Timer
$IWHUKRXUVRIRSHUDWLRQWKH&OHDQWKH)LOWHU
indicator light will glow to remind you to clean the filter.
Remove the filter and clean it.
3UHVVWRWXUQRIIWKH&OHDQWKH)LOWHUOLJKW6HHWKH&DUH
and Cleaning section.
3. Humidity Set Control Pads
7KHKXPLGLW\OHYHOFDQEHVHWZLWKLQDUDQJHRI
5+5HODWLYH+XPLGLW\WR5+5HODWLYH+XPLGLW\
LQLQFUHPHQWVRUDW16IRUFRQWLQXRXVRSHUDWLRQ7R
VHWWKHXQLWIRUFRQWLQXRXVRSHUDWLRQSUHVVWKHźSDG
XQWLOWKHVFUHHQUHDGV16
NOTE: ,I161RQVWRSLVVHOHFWHGWKHGHKXPLGLILHUZLOO
RSHUDWHFRQWLQXRXVO\DWLWVPD[LPXPGHKXPLGLILFDWLRQ
settings if attached to a hose to drain or until the bucket
is full.
)RUGULHUDLUSUHVVWKHźSDGDQGVHWWRDORZHU
SHUFHQWYDOXH
)RUGDPSHUDLUSUHVVWKHŸSDGDQGVHWWRDKLJKHU
SHUFHQWYDOXH

When you first use the dehumidifier, set the humidity
FRQWUROWRRU$OORZDWOHDVWKRXUVIRUWKH
dehumidifier to achieve the humidity level. If you still
have damper air than desired, set the humidity level
WRDORZHUVHWWLQJRUVHOHFW1RQVWRSIRUPD[LPXP
dehumidification.
4. Display
6KRZVWKHVHWKXPLGLW\OHYHOZKLOHVHWWLQJWKHQVKRZV
WKHDFWXDO±DFFXUDF\URRPKXPLGLW\OHYHO
5. Fan Speed Pad
Controls the fan speed.
Press to select either High, Medium or Low fan
speed.
6HWWKHIDQFRQWUROWR+LJKIRUPD[LPXPPRLVWXUH
removal. When the humidity has been reduced and
quiet operation is preferred, set the fan control to
Medium or Low.
6. Delay Off
While the dehumidifier is in operation, press this pad to
VHWLWWRDXWRPDWLFDOO\WXUQRIILQKRXUVRUKRXUV

Other Features
Empty Light
Glows when the bucket is ready to be emptied, or when the
bucket is removed or not replaced in the proper position.
Alarm
If the bucket is full or missing for more than 3 minutes, an
DODUPZLOOVRXQGIRUDERXWVHFRQGVWRUHPLQG\RXWR
empty and replace the bucket.
Auto Shut Off
7KH:DWHU/HYHO&RQWURO6ZLWFKVKXWVRIIWKHGHKXPLGLILHU
when the bucket is full, or when the bucket is removed



RUQRWUHSODFHGLQWKHSURSHUSRVLWLRQ127()DQZLOO
FRQWLQXHWRUXQDSSUR[LPDWHO\PLQXWHVDIWHUEXFNHWLV
removed.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to run
until the frost disappears.
Power Outage
In the case of a power outage or interruption, the unit will
automatically restart, in the settings last used, after the
power is restored.
49-7759

When first using the dehumidifier, operate the unit continuously for 24 hours.

How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses on this coil
and drains into a bucket (or through a hose and drain).

It is normal for the surrounding air to become slightly
warmer as the dehumidifier operates.

Dry, clean air is drawn through the condenser where it is
heated and discharged out the top grille into the room.

Automatic Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to run
until the frost disappears.

When the coil is defrosted, the compressor or fan will
automatically restart and dehumidifying will resume.

Choosing a Location
A dehumidifier operating in a basement will have little or no
effect in drying an adjacent enclosed storage area, such as
a closet, unless there is adequate circulation of air in and
out of the area.
Correct

Ŷ'RQRWXVHRXWGRRUV
Ŷ7KLVGHKXPLGLILHULVLQWHQGHGIRULQGRRUUHVLGHQWLDO
DSSOLFDWLRQVRQO\7KLVGHKXPLGLILHUVKRXOGQRWEHXVHG
for commercial or industrial applications.

Above

OPERATING INSTRUCTIONS

Using the Dehumidifier

Wrong
Below

Ŷ3ODFHWKHGHKXPLGLILHURQDVPRRWKOHYHOIORRUVWURQJ
enough to support the unit with a full bucket of water.
Ŷ$OORZDWOHDVW±LQFKHVRIDLUVSDFHRQDOOVLGHVRI
the unit for good air circulation.
Ŷ3ODFHWKHGHKXPLGLILHULQDQDUHDZKHUHWKHWHPSHUDWXUH
ZLOOQRWIDOOEHORZƒ)ƒ&7KHFRLOVFDQEHFRPH
FRYHUHGZLWKIURVWDWWHPSHUDWXUHVEHORZƒ)ZKLFK
may reduce performance.

at

lea

st

18

inc

hs

at l

t1
eas

8in

chs

Ŷ8VHWKHGHKXPLGLILHULQFRRNLQJODXQGU\EDWKLQJDQG
GLVKZDVKLQJDUHDVWKDWKDYHH[FHVVLYHPRLVWXUH
NOTE: Place the dehumidifier away from the clothes
dryer.
Ŷ8VHWKHGHKXPLGLILHUWRSUHYHQWPRLVWXUHGDPDJH
anywhere books or valuables are stored.
Ŷ8VHWKHGHKXPLGLILHULQDEDVHPHQWWRKHOSSUHYHQW
moisture damage.
Ŷ7KHGHKXPLGLILHUPXVWEHRSHUDWHGLQDQHQFORVHGDUHD
to be most effective.
Ŷ&ORVHDOOGRRUVZLQGRZVDQGRWKHURXWVLGHRSHQLQJVWR
the room.

49-7759

NOTE: 7KHGHKXPLGLILHUKDVUROOHUVWRDLGSODFHPHQW
but it should only be rolled on smooth, flat surfaces.
Do not attempt to roll the dehumidifier on carpet or
over objects.

5

OPERATING INSTRUCTIONS

Using the Dehumidifier
Always make sure the water bucket is locked into place on the dehumidifier.

Removing Collected Water
7KHUHDUHZD\VWRUHPRYHFROOHFWHGZDWHU
Use the bucket. When the bucket is removed, the unit will
shut off. Empty and replace the bucket.

Use a hose. Water can be automatically emptied into a
floor drain by attaching a garden water hose (not included).
5HPRYHWKHEXFNHWIURPWKHIURQWRIWKHXQLW
2. Open the drain cover on the back of the unit.

drain hose

IMPORTANT: Do not use the hose if using the bucket to
collect water. When the hose is connected, water will flow
through it onto the floor instead of into the bucket.

Handle

nozzle

7KUHDGDJDUGHQKRVHQRWVXSSOLHGRQWRWKHQR]]OHFXW
to length, and lead it to the floor drain.

Bucket

NOTES:
Ŷ'RQRWUHPRYHWKHEXFNHWZKLOHWKHGHKXPLGLILHULV
RSHUDWLQJRULILWKDVMXVWVWRSSHGRSHUDWLQJ7KLVPLJKW
cause some water to drip from the drain pan.
Ŷ7KHEXFNHWPXVWEHLQSODFHDQGVHFXUHO\VHDWHGIRUWKH
dehumidifier to operate.
5HSODFHWKHEXFNHWLQWKHXQLW
NOTE: 7KHEXFNHWPXVWEHLQSODFHDQGVHFXUHO\VHDWHG
for the dehumidifier to operate.

Water Level
7KHGHKXPLGLILHUZLOOWXUQRIIDXWRPDWLFDOO\ZKHQWKHEXFNHW
is full, or when the bucket is removed or not replaced in the
proper position.

7KHEXFNHWPXVWEHUHSODFHGLQWKHSURSHUSRVLWLRQIRU
WKHGHKXPLGLILHUWRZRUN7KHOLJKWZLOOEHRQDQGWKH
dehumidifier will not run if the bucket is not in the proper
position.

Bucket Operation
'2127UHPRYHWKHIRDPSLHFHLQWKHEXFNHWDVVHPEO\
If removed the Dehumidifier will not work properly.
When the coil is defrosted, the compressor or fan will
automatically restart and dehumidifying will resume.
Foam

6

49-7759

Turn off the dehumidifier and remove the plug from the wall outlet before cleaning.

Grille and Case
To clean the case:

To clean the front grille:

8VHZDWHUDQGDPLOGGHWHUJHQW'RQRWXVH
bleach or abrasives.

8VHDYDFXXPDWWDFKPHQWRUEUXVK

Water Bucket
To clean:

To remove:

Every few weeks, clean the bucket to prevent growth of
mold, mildew and bacteria. Partially fill the bucket with clean
water and add a little mild detergent. Swish it around in the
bucket, empty and rinse.

Remove the bucket and pour out any water.

NOTE: Do not use a dishwasher to clean the water bucket.

NOTE: 7KHEXFNHWPXVWEHLQSODFHDQGVHFXUHO\VHDWHG
for the dehumidifier to operate.

To replace:
Slide the bucket into the dehumidifier.

CARE AND CLEANING

Care and Cleaning

Air Filter
7KHDLUILOWHUEHKLQGWKHIURQWJULOOHVKRXOGEHFKHFNHGDQG
FOHDQHGDWOHDVWHYHU\KRXUVRIRSHUDWLRQRUPRUHRIWHQ
if necessary.
$IWHUKRXUVRIRSHUDWLRQWKH&OHDQWKH)LOWHULQGLFDWRU
light will glow to remind you to clean the filter. Remove the
ILOWHUDQGFOHDQLW5HSODFHWKHILOWHUDQGSUHVVWKH)LOWHU
7LPHUSDGWRWXUQRIIWKH&OHDQWKH)LOWHUOLJKW
To remove:
Remove the bucket. Grasp the filter edge, and pull it
straight down and out.

Air Filter

To clean:
Clean the filter with warm, soapy water. Rinse and let the
filter dry before replacing it.

NOTE: Avoid using a dishwasher to clean the filter.

NOTE: '2127ULQVHRUSXWWKHILOWHULQDQDXWRPDWLF
dishwasher.

CAUTION

'2127RSHUDWHWKHGHKXPLGLILHU
without a filter because dirt and lint will clog it and reduce
performance.

49-7759

7

TROUBLESHOOTING TIPS

Troubleshooting Tips... Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.

Problem

Possible Cause

What To Do

Dehumidifier does not
start

The dehumidifier is unplugged.

Makes sure the dehumidifier’s plug is pushed
completely into the outlet.

The fuse is blown/circuit breaker
is tripped.

&KHFNWKHKRXVHIXVHFLUFXLWEUHDNHUER[DQGUHSODFH
the fuse or reset the breaker.

Dehumidifier has reached its
preset level or bucket is full.

7KHGHKXPLGLILHUDXWRPDWLFDOO\WXUQVRIIZKHQHLWKHU
condition occurs. Change to a lower setting or empty
the bucket and replace properly.

Bucket is not in the proper
position.

7KHEXFNHWPXVWEHLQSODFHDQGVHFXUHO\VHDWHGIRU
the dehumidifier to operate.

Power Failure.

7KHUHLVDSURWHFWLYHWLPHGHOD\XSWRPLQXWHVWR
SUHYHQWWULSSLQJRIWKHFRPSUHVVRURYHUORDG)RUWKLV
reason, the unit may not start normal heating or cooling
for 3 minutes after it turned back on.

Did not allow enough time to
remove the moisture.

:KHQILUVWLQVWDOOHGDOORZDWOHDVWKRXUVWRPDLQWDLQ
the desired dryness.

Airflow is restricted.

Make sure there are no curtains, blinds or furniture
blocking the front of back of the dehumidifier. See the
Choosing a Location section.

Dirty Filter

See the Care and Cleaning section.

The Humidity Control may not be
set low enough.

)RUGULHUDLUSUHVVWKHSDGDQGVHWWRDORZHU
SHUFHQWYDOXHRUDW161RQVWRSIRUPD[LPXP
dehumidification.

Doors and windows may not be
closed tightly.

Check that all doors, windows and other openings are
securely closed.

Clothes dryer may be blowing
moisure-laden air into the room.

,QVWDOOWKHGHKXPLGLILHUDZD\IURPWKHG\HU7KHGU\HU
should be vented to the outside.

Room temperature is too low.

Moisture removal is best at higher room temperatures.
Lower room temperatures will reduce the moisture
removal rate. Models are designed to be operated at
WHPSHUDWXUHVDERYHƒ)ƒ&

Area to be dehumidified is too
large.

7KHFDSDFLW\RI\RXUGHKXPLGLILHUPD\QRWEHDGHTXDWH

Doors and windows are open.

Close all doors and windows to the outside.

Frost appears on the coils

Dehumidifier has been turned on
recently, or room temperature is
below 41ƒF (5ƒC)

7KLVLVQRUPDO)URVWZLOOXVXDOO\GLVDSSHDUZLWKLQ
minutes. See the Automatic Defrost section

Control cannot be set

The compressor will turn off and
the fan will automatically continue
to run for approximately 3 minutes
at a fixed setting.

7KLVLVQRUPDO:DLWDSSUR[LPDWHO\PLQXWHVDQGVHW
the fan as desired.

Fan noise

Air is moving through the
dehumidifier.

7KLVLVQRUPDO

Water on floor

Hose connection may be loose.

Check the hose connection. See the Removing
Collected Water section.

Intended to use the bucket to
collect water, but a hose was
attached.

Disconnect the hose if using a bucket to collect water.
See the Removing Collected Water section.

Drain hose not tight on fitting.

Check drain hose connection.

Drain hose is kinked.

Ensure the drain hose is pointed straight down to the
floor and is not kinked in anyway.

Dehumidifier does not dry
the air as it should

Dehumidifier runs too
much

Bucket Full LED light
flashing and alarm sounds
while drain hose is
connected.

8

49-7759

49-7759

NOTES

Notes

9

NOTES


Notes

49-7759

For The Period Of: GE Appliances Will Replace:
One Year
)URPWKHGDWHRIWKH
original purchase

Replacement unit for any product which fails due to a defect in materials or workmanVKLS7KHUHSODFHPHQWXQLWLVZDUUDQWHGIRUWKHUHPDLQGHURI\RXUSURGXFW¶VRULJLQDO
one-year warranty period. The replacement unit may either be a new unit or a
refurbished unit.

WARRANTY

GE Appliances Dehumidifier Warranty

In Order to Make a Warranty Claim During the First 90 Days from the Date of Original Purchase:
Ŷ Properly pack your unit. We recommend using
the original carton and packing materials.
Ŷ5HWXUQWKHSURGXFWWRWKHUHWDLOORFDWLRQZKHUH
it was purchased.

Ŷ Include in the package a copy of the sales receipt
or other evidence of date of original purchase. Also
print your name and address and a description of
the defect.

In Order to Make a Warranty Claim During the Remainder of the One-Year Warranty:
Ŷ/RFDWH\RXURULJLQDOVDOHVUHFHLSWDQGPDNHDQRWH
Ŷ
Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2016:10:11 11:11:49-04:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2016:10:11 11:11:49-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2016:10:11 11:11:30-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:dec25284-cb2c-4954-8beb-b9c18730b712
Instance ID                     : uuid:d664ba02-6ba6-4fff-b9e1-93097a27dc94
Producer                        : Acrobat Distiller 10.1.16 (Windows)
Page Count                      : 24
EXIF Metadata provided by EXIF.tools

Navigation menu