Gallagher Group C30044XA Prox Readers T11 Multi Tech, T11 Multi Tech PIV and T12 Multi Tech User Manual Users Mnual
Gallagher Group Ltd Prox Readers T11 Multi Tech, T11 Multi Tech PIV and T12 Multi Tech Users Mnual
Contents
- 1. Users Mnual
- 2. Users Manual 2
- 3. Users Manual
Users Mnual
Page 1
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
Gallagher
T11 Reader
Installaon Note
T11 Mifare Reader Black: C300410
T11 Mifare Reader White: C300411
T11 Mul Tech Reader Black: C300430
T11 Mul Tech Reader White: C300431
T11 PIV Reader Black: C305410
T11 PIV Reader White: C305411
T11 PIV Reader - Mul Tech Black: C305430
T11 PIV Reader - Mul Tech White: C305431
Page 2
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
Disclaimer
This document gives certain informaon about products and/or services provided by Gallagher Group Limited
or its related companies (referred to as "Gallagher Group").
The informaon is indicave only and is subject to change without noce meaning it may be out of date at any
given me. Although every commercially reasonable eort has been taken to ensure the quality and accuracy
of the informaon, Gallagher Group makes no representaon as to its accuracy or completeness and it should
not be relied on as such. To the extent permied by law, all express or implied, or other representaons or
warranes in relaon to the informaon are expressly excluded.
Neither Gallagher Group nor any of its directors, employees or other representaves shall be responsible
for any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the
informaon provided.
Except where stated otherwise, the informaon is subject to copyright owned by Gallagher Group and you may
not sell it without permission. Gallagher Group is the owner of all trademarks reproduced in this informaon.
All trademarks which are not the property of Gallagher Group, are acknowledged.
Copyright © Gallagher Group Ltd 2016. All rights reserved.
Page 3
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
Contents
1 Introducon ..................................................................................................................................... 4
2 Before you begin .............................................................................................................................. 5
3 Distance between readers ............................................................................................................... 7
4 Installaon ....................................................................................................................................... 8
5 LED indicaons ............................................................................................................................... 10
6 Accessories .................................................................................................................................... 10
7 Technical specicaons .................................................................................................................. 11
8 Approvals and standards ................................................................................................................ 12
9 Mounng dimensions .................................................................................................................... 13
Page 4
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
1 Introducon
The Gallagher T11 Reader is a mobile credenal and smart card proximity reader. It can be installed as
either an entry reader or exit reader. It can be mounted on a vercal, rectangular 50 mm x 75 mm (2" x
3") ush box with mounng holes spaced at a nominal 85 mm (3.25").
The reader sends informaon to the Gallagher Controller and acts upon informaon sent from the
Gallagher Controller. The reader itself does not make any access decisions.
The reader is available in eight variants. The card technologies for each variant are shown below.
Reader Product codes Supported card technologies
T11 Mifare Reader Black
T11 Mifare Reader White
C300410
C300411
Mifare DESFire EV1, Mifare Plus and
Mifare Classic
T11 Mul Tech Reader Black
T11 Mul Tech Reader White
C300430
C300431
Mifare DESFire EV1, Mifare Plus, Mifare
Classic and 125 KHz cards
T11 PIV Reader Black
T11 PIV Reader White
C305410
C305411
PIV, PIV-I, Mifare DESFire EV1, Mifare
Plus and Mifare Classic
T11 PIV Reader - Mul Tech Black
T11 PIV Reader - Mul Tech White
C305430
C305431
PIV, PIV-I, Mifare DESFire EV1, Mifare
Plus, Mifare Classic and 125 KHz cards
The reader can be connected as an HBUS Reader or Cardax IV Reader. An HBUS Reader uses the HBUS
communicaons protocol to communicate with the Gallagher Controller. A Cardax IV Reader uses the
Cardax IV Reader communicaons protocol to communicate with the Gallagher Controller.
IMPORTANT: HBUScompability
HBUS communicaons are supported with sites running Gallagher Command Centre vEL7.00 soware
(or later).
IMPORTANT: MulTechreaders
Using dual technology 125/Mifare cards with Gallagher Mul Tech readers may cause both card
technologies to be read, resulng in double card badges and unusual reader feedback. Gallagher
strongly recommends against using dual technology 125/Mifare cards with Mul Tech readers for sites
running pre-Command Centre v7.00 soware. From Command Centre v7.00, a site may specify which
technology a Mul Tech reader should read o a dual technology card.
IMPORTANT: PIV readers
Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only (referred
to as the Controller). Gallagher PIV readers can only be used with sites running Gallagher Command
Centre vEL7.10 soware (or later). Gallagher PIV readers are connected as HBUS Readers only.
IMPORTANT: Mobilecredenalreaders
Gallagher Mul Tech readers support Gallagher mobile credenals using Bluetooth® wireless
technology. Mobile credentials are supported with sites running Gallagher Command Centre vEL7.60
soware (or later). To use mobile credenals, the Mul Tech reader must be connected as an HBUS
Reader.
Page 5
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
2 Beforeyoubegin
2.1 Shipment contents
Check the shipment contains the following items:
• 1 x Gallagher T11 Reader facia assembly
• 1 x Gallagher T11 Reader bezel
• 1 x M3 Torx Post Security screw
• 2 x 6-32 UNC Phillips drive xing screws
• 4 x 25 mm No.6 self tapping, pan head, Phillips drive xing screws
• 4 x 40 mm No.6 self tapping, pan head, Phillips drive xing screws
2.2 Powersupply
The Gallagher T11 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc
measured at the reader terminals. The operang current draw is dependant on the supply
voltage at the reader. For the Mifare reader, at 13.6 Vdc the current draw is 84 mA (idle). During
card read, beeper and LED acvity, the current will momentarily reach 113 mA (maximum). For
the Mul Tech reader, at 13.6 Vdc the current draw is 100 mA (idle) and will momentarily reach
124 mA (maximum). The power source should be linear or a good quality switched-mode power
supply. The performance of the reader may be aected by a low quality, noisy power supply.
2.3 Cabling
The Gallagher T11 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded
security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When
using a single cable to carry both power supply and data, both the power supply voltage drop
and data requirements must be considered. Although the reader is specied to operate at 9
Vdc, for good engineering design it is recommended that the voltage at the reader should be
approximately 12 Vdc.
HBUScablingtopology
The HBUS communicaons protocol is based on the RS485 standard and allows the reader to
communicate over a distance of up to 500 m (1640 ).
The cabling between HBUS devices should be done in a "daisy chain" topology, (i.e. A "T" or
"Star" topology should not be used between devices). Should "Star" or "Home-Run" wiring be
required, the HBUS 4H/8H Modules and the HBUS Door Module allow mulple HBUS devices to
be individually wired to the one physical locaon.
The end devices on the HBUS cable should be terminated using 120 ohms resistance. To
terminate the Gallagher Controller 6000, connect the supplied on-board terminaon jumpers
to the Controller. To terminate a reader, connect the orange (terminaon) wire to the green
(HBUS A) wire. Terminaon is already included at the HBUS Module, (i.e. each HBUS port is
permanently terminated at the module).
Page 6
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
Connect the on-board
terminaon jumper
Controller 6000
RS485 1
HBUS
Device
"T" or "Star" circuits are
not permied between
HBUS devices
HBUS
Device
Terminate
HBUS
Device
HBUS
Device
HBUS
Device
HBUS
Device
HBUS
Device
HBUS
Device
Terminate
Remove the on-board
terminaon jumper
RS485 1
"T" or "Star" circuits are
not permied between
HBUS devices
HBUS
Device
Terminate
HBUS
Device Controller 6000
HBUS
Device
"T" or "Star" circuits are
not permied between
HBUS devices
Controller 6000
H1 H4
H8
H5
HBUS
Device
Terminate
HBUS
Device
Terminate
HBUS Module
HBUS
Device
HBUS
Device
Terminate
HBUS
Device
Terminate
HBUS
Device
Page 7
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
Cabledistance
Cabletype Cableformat* HBUS
single reader
connected using
dataonlyina
singlecable
Cardax IV
single reader
connected using
dataonlyina
singlecable***
HBUS/Cardax IV
single reader
connected using
power and data
inasinglecable
CAT 5e or
beer**
4 twisted pair
Each 2 x 0.2 mm2
(24 AWG)
500 m (1640 ) 200 m (650 ) 100 m (330 )
BELDEN 9842**
(shielded)
2 twisted pair
Each 2 x 0.2 mm2
(24 AWG)
500 m (1640 ) 200 m (650 ) 100 m (330 )
SEC472 4 x 0.2 mm2
Not twisted
pairs (24 AWG)
400 m (1310 ) 200 m (650 ) 100 m (330 )
SEC4142 4 x 0.4 mm2
Not twisted
pairs (21 AWG)
400 m (1310 ) 200 m (650 ) 150 m (500 )
* The matching of wire sizes to equivalent wire gauges are only approximate.
** Recommended cable types for opmal HBUS RS485 performance.
*** Not applicable for PIV or Gallagher mobile credenal reader installaons.
Notes:
• Shielded cable may reduce the obtainable cable length. Shielded cable should be
grounded at the Controller end only.
• If other cable types are used, operang distances and performance may be reduced
depending on the cable quality.
• HBUS allows up to 20 readers to be connected to a single cable. Each reader requires at
least 9 Vdc to funcon correctly. The cable length and the number of readers connected
will have an impact on the voltage at each reader.
3 Distancebetweenreaders
The distance separang any two proximity readers must not be less than 200 mm (8 in) in all direcons.
When mounng a proximity reader on an internal wall, check that any reader xed to the other side of
the wall is not less than 200 mm (8 in) away.
200 mm
200 mm
Page 8
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
4 Installaon
ATTENTION: This equipment contains components that can be damaged by
electrostac discharge. Ensure both you and the equipment are earthed before
beginning any servicing.
The Gallagher T11 Reader is designed to be mounted on vercally orientated electrical ush (gang)
boxes, or any solid at surface. However installaon on metal surfaces, parcularly those with a large
surface area will reduce read range. The extent to which the range is reduced will depend upon the
type of metal surface.
Note: Consideraon should be given to the installaon environment when using Gallagher mobile
credenals, as the Bluetooth® wireless technology read range may be reduced.
The recommended mounng height for the reader is 1.1 m (3.6 ) from the oor level to the centre of
the reader device. However this may vary in some countries and you should check local regulaons for
variaons to this height.
1. Ensure the building cable has been run out through the ush box.
If you are not mounng to a ush box, use the reader bezel as a guide to drill all ve holes. Drill
the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable
will exit the mounng surface) and the four xing holes.
2. Run the building cabling out through the centre hole and through the reader bezel.
3. Secure the bezel to the ush box using the two 6-32 UNC screws provided. It is important the
reader bezel is ush with and ght against the mounng surface.
If you are not mounng to a ush box, secure the bezel to the mounng surface using the four
xing screws provided.
Note: It is strongly recommended that you use the screws provided. If an alternave screw is
used, the head must be no larger nor deeper than that of the screw provided.
Note: Ensure the centre hole allows the cable to run freely out through the mounng surface, so
that the reader facia can clip into the bezel.
Building cable
6-32 UNC screw
6-32 UNC screw
Bezel
4. Connect the reader tail extending from the facia assembly to the building cable. Connect the
wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV
Reader, as shown in the following diagrams.
Note: Gallagher PIV and mobile credenal readers must be connected as HBUS Readers.
Page 9
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
Gallagher PIV readers connect to the Gallagher Controller 6000 High Spec PIV (C305101) only.
An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (aached to
a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).
A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (aached
to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher
Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or
a Gallagher Local Bus Reader I/O Interface.
HBUS Reader connecon: HBUS Reader terminated:
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
HBUS Reader
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
HBUS Reader
Note: To terminate an HBUS Reader, connect the Orange (HBUS Terminaon) wire to the Green
(HBUS A) wire.
Cardax IV Reader connecon:
Posive Red
Negave Black
HBUS Terminaon Orange
HBUS A Green
HBUS B Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
5. Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding
the top, press the boom of the facia assembly down into the bezel.
6. Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the
hole at the boom of the bezel to secure the facia assembly.
Note: The Torx Post Security screw needs only to be lightly ghtened.
Connecon
Reader tail Building cable
Fit screw to secure facia to bezel
Facia
Page 10
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
7. Removal of the facia assembly is a simple reversal of these steps.
8. Congure the reader in Command Centre. If the reader is connected as an HBUS Reader, refer to
the topic "Conguring HBUS Devices" in the Command Centre Conguraon Client Online Help.
If the reader is connected as a Cardax IV Reader, refer to the topic "Creang Readers" in the
Command Centre Conguraon Client Online Help.
5 LEDindicaons
LED (squiggle) HBUSindicaon
3 Flash (Amber) No communicaons with the Controller.
2 Flash (Amber) Communicaons with the Controller, but reader is not congured.
1 Flash (Amber) Congured to a Controller, but reader is not assigned to a door or elevator car.
On (Green or Red) Fully congured and funconing normally.
Green = Access mode is Free
Red = Access mode is Secure
Flashes Green Access has been granted.
Flashes Red Access has been denied.
Flashes (Blue) Reading and validang a PIV card. Reading a Gallagher mobile credenal.
LED (squiggle) CardaxIVindicaon
3 Flash (Amber) No communicaons with the Controller.
On (Green or Red) Fully congured and funconing normally.
Green = Access mode is Free
Red = Access mode is Secure
Flashes Green Access has been granted.
Flashes Red Access has been denied.
6 Accessories
Accessory Product Code
T11 Dress Plate, Black, Pk 10 C300321
T11 Bezel, Black, Pk 10 C300284
T11 Bezel, White, Pk 10 C300285
T11 Bezel, Silver, Pk 10 C300286
T11 Bezel, Gold, Pk 10 C300287
T11 Spacer, Black, Pk 10 C300302
T11 Spacer, White, Pk 10 C300303
T11/T12 Protecve Cover Spacer C300311
T11/T12 Protecve Cover C300271
Page 11
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
7 Technicalspecicaons
Roune maintenance: Not applicable for this reader
Cleaning: This reader should only be cleaned with a clean, lint free, damp cloth
Voltage: 9 Vdc - 16 Vdc
Current: Mifare Reader Mul Tech Reader
Idle 1 Maximum 2 Idle 1 Maximum 2
at 9 Vdc 124 mA 175 mA 115 mA 164 mA
at 13.6 Vdc 84 mA 113 mA 100 mA 124 mA
Temperature range: -35 °C to +70 °C
Note: Direct sunlight may increase the internal reader temperature
above the ambient temperature level
Humidity: 0 - 95% non-condensing 3
Environmental protecon: IP68
Impact rang: IK07
Unit dimensions: Height 115 mm (4.5")
Width 70 mm (2.8")
Depth 12 mm (0.5")
Maximum number of readers
on one HBUS cable:
20
1 The reader is idle.
2 Peak current during card read.
3 Gallagher T Series readers are UL humidity tested and cered to 85% and have been independently
veried to 95%.
Note: The current values stated above have been reported using the default conguraon for a reader
in Command Centre. Changing the conguraon may vary the current value.
Page 12
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
8 Approvals and standards
This symbol on the product or its packaging indicates that this product must not be disposed
of with other waste. Instead, it is your responsibility to dispose of your waste equipment by
handing it over to a designated collecon point for the recycling of waste electrical and electronic
equipment. The separate collecon and recycling of your waste equipment at the me of disposal
will help conserve natural resources and ensure that it is recycled in a manner that protects human
health and the environment. For more informaon about where you can drop o your waste
equipment for recycling, please contact your local city recycling oce or the dealer from whom
you purchased the product.
FCC This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operaon.
Note: Changes or modicaons not expressly approved by Gallagher Limited could void the user's
authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protecon against harmful interference in a residenal installaon. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instrucons, may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this equipment does cause
harmful interference to radio or television recepon, which can be determined by turning the
equipment o and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separaon between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Industry
Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to
the following two condions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operaon of the device.
Industrie
Canada
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitaon est autorisée aux deux condions suivantes : (1) l'appareil
ne doit pas produire de brouillage, et (2) l'ulisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement.
ETSI EN 300 330-2 V1.5.1:2011
EN50130-4:2011
Please refer to the document “3E2793 Gallagher Command Centre UL Conguraon Requirements” for a guide
to conguring the Gallagher system to the appropriate UL Standard.
US - Equipment: com, burg and acc reader
CA - Equipment: com, burg reader
Page 13
3E4289 Gallagher T11 Reader | Edion 1 | August 2016
Copyright © Gallagher Group Limited
9 Mounngdimensions
IMPORTANT
This picture is not to scale, therefore use the measurements provided.
40 mm (1.57")
32 mm (1.26") 48 mm (1.89")
115 mm (4.53")
13 mm (1/2")
diameter hole for cable
70 mm (2.76")
22.5 mm
(0.89")
40 mm (1.57")
Mifare Card
read area
125 Card
read area