Gigaset Communications MD40 DECT module User Manual Installation Guide

Gigaset Communications GmbH DECT module Installation Guide

Contents

Installation Guide

Download: Gigaset Communications MD40 DECT module User Manual Installation Guide
Mirror Download [FCC.gov]Gigaset Communications MD40 DECT module User Manual Installation Guide
Document ID1573090
Application IDOuTkvn9b7AQ2YvQBd3hqXg==
Document DescriptionInstallation Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.48kB (131058 bits)
Date Submitted2011-11-03 00:00:00
Date Available2011-11-03 00:00:00
Creation Date2011-09-23 12:10:48
Producing SoftwareAcrobat Distiller 9.4.6 (Windows)
Document Lastmod2011-09-23 12:10:48
Document TitleMicrosoft Word - MD40_OEM Instructions_22 09 2011 _2_
Document CreatorPScript5.dll Version 5.2.2
Document Author: pc-8741

OEM instructions
The manufacturer of the end product shall consider the following hints:
1) The end product (host) with the module built inside must be marked as follows:
Contains Transmitter Module FCC ID: TVU‐MD40 / IC: 8023A‐MD40
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Module transmetteur ID IC: 8023A‐MD40.
Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas
causer d’interférences nuisibles et (2) appareil doit accepter toute interference recue, y
compris les interferences qui peuvent pertuber le fontionnement.
2) The following regulatory statements shall be printed in the user manual for the end
product.
FCC Information:
Changes or modifications to the equipment not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for Class B digital
device, pursuant to Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause undesired
operation.
These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the system off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the end product and receiver.
3. Connect the end product into an outlet on a circuit different from that to which the
receiver is connected.
4. Consult the dealer or an experienced radio TV technician for help.
16.09.2011
Page 1 of 6
Industry Canada Information:
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
NOTICE: The Industry Canada label identifies certified equipment. This certification means
that the equipment meets certain telecommunications network, protective, operational and
safety requirements as prescribed in the appropriate Terminal
Equipment Technical Requirements document(s). The Department does not guarantee the
equipment will operate to the user’s satisfaction.
Repairs to certified equipment should be coordinated by a representative designated by the
supplier.
Users should ensure for their own protection that the electrical ground connections of the
power utility, telephone lines and internal metallic water pipe system, if present, are
connected together.
This precaution may be particularly important in rural areas.
NOTE: Users should not attempt to make such connections themselves, but should contact
the appropriate electric inspection authority, or electrician, as appropriate. This product
meets the applicable Industry Canada technical specifications.
This Class B digital apparatus complies with Canadian ICES‐003.
Cet appareil numérique de la classe B est conforme à la norme NMB‐003 du Canada.
3) General Information
A host product is required to comply with all applicable FCC equipment authorizations
regulations, requirements and equipment functions not associated with the transmitter
module portion. For example, compliance must be demonstrated to regulations for other
transmitter components within the host product; to requirements for unintentional
radiators (Part 15B), such as digital devices, computer peripherals, radio receivers, etc.; and
to additional authorization requirements for the non‐transmitter functions on the
transmitter module (i.e., Verification, or Declaration of Conformity) (e.g., Bluetooth and WiFi
transmitter modules may also contain digital logic functions) as appropriate.
To ensure compliance with all non‐transmitter functions the host manufacturer is
responsible for ensuring compliance with the module(s) installed and fully operational. For
example, if a host was previously authorized as an unintentional radiator under the
Declaration of Conformity procedure without a transmitter certified module and a module is
added, the host manufacturer is responsible for ensuring that after the module is installed
and operational the host continues to be compliant with the Part 15B unintentional radiator
requirements.
22.09.2011
Page 2 of 6
Single or limited‐single modules and the RF front‐end section of a split or limited split‐
module must be a separate physical assembly that can be installed into (or attached to) a
host as a separate sub‐assembly (daughter‐board sub‐assembly). The method used for input
and output electrical connections to the host can be soldered, cabled, wired, or use plug‐in
connectors. A module cannot be solely the implementation of a design specification. Only
the control‐element section of a split‐module device may comprise software certified as
companion code to a specific RF front‐end (section).
A host using a component that has been authorized as a module may, subject to the
requirements described below and the conditions of the grant, (1) be marketed and sold
with the module built inside that does not have to be end‐user accessible/replaceable, or (2)
be marketed with the module being end‐user plug‐and‐play replaceable.
The antenna(s) used for this transmitter must not be collocated or operated in conjunction
with any other antenna or transmitter within a host device, except in accordance with FCC
multi‐transmitter product procedures.
The Gigaset MD40 will be delivered with default settings which fulfill the regulatory
standards. If parameters are changed, the conformity to the regulatory standards could not
be fulfilled. The distributor has to prove the conformity to the regulatory requirements again
4) Safety Instructions
In customer related documents of the end product like instruction manuals, installation
guides etc. appropriate safety instructions have to be included.
The supplier of the complete system is responsible for these safety instructions.
The transmitted RF‐signal is modulated in a time multiplex process with a frame length of
10ms (100Hz). A possible demodulation in devices with electro‐acoustically transducers can
cause a humming noise.
The transmitted RF‐signal can cause malfunctions in electronic devices located close to the
module.
The specific external power supply for the Cordless Voice Module SC14CVMDECT has to
fulfill the requirements according to clause 2.5 (Limited power source) of this standard EN
60950‐1:2006.
Interconnection circuits shall be selected to provide continued conformance to the
requirements of clause 2.2 for SELV (Safety Extra Low Voltage) circuits according to EN
60950‐1:2006 after making connections.
22.09.2011
Page 3 of 6
Requirements additional to those specified in common safety standards may be necessary
for:
‐ Equipment intended for operation in special environments (for example, extremes of
temperature, excessive dust, moisture or vibration, flammable gases and corrosive or
explosive atmospheres).
‐ Equipment intended to be used in vehicles, on board ships or aircraft, in tropical countries
or at altitudes greater than 2000 m.
‐ Equipment intended for use where ingress of water is possible.
Installation by qualified personnel only!
The product is a component intended for installation and use in complete equipment. The
final acceptance of the component is dependent upon its installation and use in complete
equipment.
Gigaset MD40 contains an internal fuse which is implemented as a track on the PCB.
The fuse is tripped at a current of 3 ‐ 4A. The module has to be exchanged if the fuse is
blown.
Medical and electronic devices can be affected in their function.
Consider the technical conditions of your surrounding e.g. medical practice.
The Gigaset MD40 can cause annoying noise in hearing aids.
Point your customer to the fact that your system/device behaves like a cordless telephone.
This applies especially for the indoor and outdoor range.
Also consider that the radio link can be interrupted by external environmental influences
(e.g. motor vehicles which affect the radio coverage at the range limit).
Without a sufficient supply voltage (e.g. an empty battery) the equipment can’t work
correctly.
22.09.2011
Page 4 of 6
5) Installation guide
The module shall be operated only with the voltage stated in the specification.
The module contains an internal fuse which is implemented as a track on the PCB.
The fuse is tripped at a current of 3 ‐ 4A. The module has to be exchanged if the fuse is
blown.
The MD40 is intended to be fixed at the host board with two M2.5 screws on distance bolts.
The two distance bolts must have a length of 6.2mm (+‐ 0.2mm) and a diameter of
4mm (+‐ 0.5mm).
The module is supplied with two DECT‐antenna springs.
The internal antennas are installed by plugging the antenna springs into the antenna ports.
It is recommended to protect the antennas against mechanical shocks or vibration in the
host device in which the engine is installed.
The module is conform with the FCC and Industry Canada regulations with the provided
internal antennas (C39363‐A290‐B35 / Johann Vitz GmbH & Co. KG) only.
If other antennas are used in the end product, a new assessment of conformity with the
regulatory standards is mandatory.
22.09.2011
Page 5 of 6
For optimum performance, an antenna generally needs to be surrounded by an
unobstructed space a few wavelengths in size.
Any dielectric or conducting material in the immediate vicinity of an antenna affects the
radiation pattern and performance of the antenna. Hence, whenever mechanical design
allows, as much space as possible must be left clear around the antenna spring (min. 40mm).
This ensures that the impact of surrounding PCBs or other conducting parts (cables etc.) on
the antenna’s performance can be kept at an acceptable level.
If, for mechanical reasons, there is only limited room around the engine’s antenna springs,
the effect of this on the antenna’s performance and FCC / Industry Canada type approvals
needs to be taken into account, together with the resulting reduction in achievable range.
For the purposes of ESD protection, internal antennas must have an air gap of at least 10
mm from any possible position of the ESD test finger or test probe, to avoid an air discharge.
If external antennas are used, the ground shield of the coaxial cable is connected to the
ground of the host interface. The requirements of the safety standards have to be
considered.
Air discharge onto the external antenna or the antenna connectors may cause temporary
loss of synchronization between the fixed part and the portable part. In V.24 replacement
mode this results in an interruption of the connection for several seconds. In GAP‐PP mode
the connection will be released.
To avoid these effects, care should be taken in designing the housing and the arrangement
of the external antennas. The coaxial cable shielding must be prevented from conduction the
discharge current away over the DECT Engine e.g. by a direct ground connection to a metal
housing on the antenna connector. If a plastic housing is used, all metallic surfaces must be
covered by plastic material. Metallic surfaces should have an air gap of at least 10 mm from
any possible position of the ESD test finger or test probe, to avoid an air discharge.
22.09.2011
Page 6 of 6

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : pc-8741
Create Date                     : 2011:09:23 12:10:48+02:00
Modify Date                     : 2011:09:23 12:10:48+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.4.6 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - MD40_OEM Instructions_22 09 2011 _2_
Creator                         : pc-8741
Document ID                     : uuid:fe0ad829-e182-426b-b045-b80b42b167ee
Instance ID                     : uuid:81bb8a9f-b325-4779-bdeb-cf7402b2e7f6
Page Count                      : 6
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TVU-MD40

Navigation menu