33620 Electric 20Air 20module 20 20RPM 20Sensor EN

2016-05-14

: Graupner 33620 Electric-20Air-20Module-20-20Rpm-20Sensor En 33620_Electric-20Air-20module-20-20RPM-20Sensor_EN TELEMETRY

Open the PDF directly: View PDF PDF.
Page Count: 2

<Electric Air module RPM sensor>
RPM Sensor could be connected with CS port. Due to the current structure (the CS port of Electric module is not
connected with power), you need to work for it as below. Please connect the pins together as below the photo
(red colored). And please be careful for short circuit.
To use the RPM sensor, at the user setup page No. 5 of the Electric module, you could set the CS port type by
RPM and also set the Blade/magnet number according to the related product. And please save the data after
setting. And then, the Magnet RPM sensor and Phase RPM sensor would work if you connect the sensor with CS
port. To use the Optic RPM sensor, you could connect the sensor with the cable of the external regulator board
S8364. Attention! Use RPM sensors only with adapter board S8364, otherwise the processor will be destroyed,
because of over voltage!
Optic RPM Sensor
As the above photo,
you could connect the
CS port and the Optic
RPM sensor.
< Added Warning and User setting screen from the RPM sensor working >
Warning Setting Screen page 21, 22
1. Minimum RPM : to set the starting time for the warning, 500 to 200000 (unit : 10 RPM)
(Initial value: 500)
2. Warning time : Off
3. Repeat time : Always
4. Signal Tone : T
1. maximum RPM : to set the starting time for the warning, 7000 to 200000 (unit : 10 RPM)
(Initial value: 7000)
2. Warning time : Off
3. Repeat time : Always
4. Signal Tone : Y
User setting screen page 5
1. Number : To set the numbers of Blade / Magnet, 1 to 6 (unit : 1)
2. CS port type : To set the application of the CS port
To set CS for Current control function and To set RPM for RPM sensor
Minimum RPM
>Set warning : Page21
Minimum RPM: 500
Warning Time: Off
Repeat Time: ALWAYS
Signal Tone: T
RPM( ) : 0
Blade / Magnet Number
>User Setup : Page 5
Number : 1
CS Port Type : RPM
Maximum RPM
>Set warning : Page22
Minimum RPM: 7000
Warning Time: Off
Repeat Time: ALWAYS
Signal Tone: Y
RPM( ) : 0

Navigation menu