Honeywell Emm 3U Product Data ManualsLib Makes It Easy To Find Manuals Online!
2014-12-11
: Honeywell Honeywell-Emm-3U-Product-Data-120149 honeywell-emm-3u-product-data-120149 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
EMM-3U Universal Electronic MiniZone™ Panel PRODUCT DATA FEATURES • Compatible with single-stage, multi-stage, conventional or heat pump applications. • Uses virtually any Honeywell four-wire, single-stage, multi-stage, or Trol-A-Temp heat pump thermostat. • Optional Discharge Air Temperature Sensor for capacity control with adjustable high and low limits. • System and Zone LEDs indicate system status. • Automatic zone changeover with 20-minute changeover timer. • Individual zone fan control. • Thermal circuit breaker protects panel and transformer from damage if miswired. • Purge timer protects equipment between calls for heating and cooling. APPLICATION • Uses spring-open/power-closed, spring-closed/poweropen, and power-open/power-closed dampers. • Single or dual transformer equipment compatible. The EMM-3U Universal Electronic MiniZone™ Panel controls single-stage, multi-stage, conventional or heat pump heat/cool equipment and is used on two- and three-zone applications. For Internet access: www.honeywellzoning.com For technical support, call 1-800-828-8367. To download Zoning literature: http://hbctechlit.honeywell.com Contents Application ........................................................................ 1 Features ........................................................................... 1 Specifications ................................................................... 2 Ordering Information ........................................................ 2 Installation ........................................................................ 4 Troubleshooting ................................................................ 15 ® U.S. Registered Trademark Copyright © 2002 Honeywell • All Rights Reserved 68-0237-2 EMM-3U UNIVERSAL ELECTRONIC MINIZONE™ PANEL SPECIFICATIONS Wiring Connections: Thermostat: R-C-E-W1-Y1-G-W2-Y2-O-B-L. Dampers: M6 (Closed); M4 (Open); M1 (Common). Discharge Air Temperature Sensor: DATS-DATS. Transformer: R-C. Equipment: RC-RH-W1-W2-E-B-O-Y1-Y2-G. Input Ratings: Voltage: 20 - 30 Vac, 50/60 Hz. Power: 10.75 VA nominal. Output Ratings: Equipment Relays and Zone Relays: 1.5A run, 3.5A inrush, 200,000 cycles (30 Vac). 1.5A run, 7.5A inrush, 100,000 cycles (30 Vac). Humidity Ratings: 5% to 90% RH non-condensing. Temperature Ratings: Shipping: -20° to 120°F. Operating: -40° to 150°F. LED: SYSTEM mode LED (5) used to communicate equipment status: Red Heat: Heat mode. Green Cool: Cool mode. Yellow Purge: Purge mode. Green Fan: Fan mode. Red EM Heat: Emergency Heat mode. Flashing Red Heat: System exceeds high DATS input. Flashing Green Cool: System exceeds low DATS input. Flashing Yellow Purge: No DATS or DATS failure. Off: Idle mode. ZONE LED (3) used to communicate damper status: Green: Dampers are opening or open. No Color: Dampers are closing or closed. 10-3/4 (273) 12-3/4 (273) 1-7/8 (47) M20779A Fig. 1. EMM-3U dimensions in in. (mm). Approvals: Federal Communications Commission: Class B. NEMA DC-3: Not required. Finish: Taupe cover. Gray base. Dimensions: See Fig. 1. Mounting: Mounts with four one-inch no. 8 screws (provided) through holes in cabinet. Wall anchors provided. Wiring: 18 to 22 gauge wire for all equipment and system connections. Thermostats (See Table 1): Most conventional four-wire (R, W, Y, G) thermostats can be used to control conventional, heat pump, or multi-stage equipment. Manual or automatic changeover switching thermostats can be used. Multi-stage or select heat pump thermostats can also be used. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone (1-800-468-1502): 1. 2. Your local Automation and Control Solutions Sales Office (check white pages of your phone directory). Honeywell Automation and Control Solutions Customer Care 1985 Douglas Drive North Golden Valley, MN 55422 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0237-2 2 EMM-3U UNIVERSAL ELECTRONIC MINIZONE™ PANEL Recommended Dampers (See Table 2): Five ZD or ARD dampers maximum connected to each panel and a maximum of five dampers per zone. Use SDCR for additional dampers required on one zone. Dampers are connected to M1 Common, M4 Open, and M6 Closed (see Fig. 8-12 for hookups). Table 1. Recommended Thermostats. System SingleStage Heat Pumpb MultiStageb Non-Programmable T87F1859/Q539A1014 T87F4010/Q539A4026 T8501D1046 T8400C1016 T8400C1040 T8400C1099 T8501D1111 Y594R1243a,c,d Y594G1252a,e T8411R1002 T8411R1028 T8424D1008 T8424D1016 T8524D1007 T8524D1015 Y594D1347f T8524D1015 Programmable T8601D2027 T8600D2069 T8600D2028 T8601D2019 T8602D2018 T8602D2000 T8000C1002 T8000C1010 T8001C1019 PC8900/W8900A,C Table 2. Recommended Dampers. Honeywell Damper Type Round Rectangular Power-open/power closed (for systems >2000 cfm) MARD D642 using ML6161 Motor Actuator Spring-open/power-closed (for systems
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Create Date : 2013:09:28 23:00:17Z Keywords : manuals, instruction manuals, user manuals, service manuals, user guides, pdf manuals, owners manuals, installation guides Modify Date : 2014:12:07 14:58:20+08:00 Subject : Search through 700.000 manuals online & and download pdf manuals. Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : Provided By MANUALSLIB.COM - http://www.manualslib.com/ Description : Search through 700.000 manuals online & and download pdf manuals. Title : ManualsLib - Makes it easy to find manuals online! Creator Tool : pdftk 1.44 - www.pdftk.com Metadata Date : 2014:12:07 14:58:20+08:00 Producer : itext-paulo-155 (itextpdf.sf.net-lowagie.com) Document ID : uuid:76ad0a29-36cb-2e4b-93e2-08da10b89d83 Instance ID : uuid:868d556d-ca25-7d42-b5da-f9241510fac5 Page Count : 16EXIF Metadata provided by EXIF.tools