Installation, Operation, &
Maintenance Instruction
Models DC2, 3, 4, 5, and 6

Bulletin #: IOM-OM-1104- E

Manufacturers of Quality Pumps,
Controls, and Systems

STANDARD PUMP OPERATIONS
27101 Airport Road
Punta Gorda, FL
33982
(941) 575-3800
Fax (941) 575-4085
www.pulsatron.com

Pulsafeeder Factory Service Policy
Should you experience a problem with your Pulsafeeder pump, first consult the troubleshooting guide in
your operation and maintenance manual. If the problem is not covered or cannot be solved, please
contact your local Pulsafeeder Sales Representative or Distributor, or our Technical Services Department
for further assistance.
Trained technicians are available to diagnose your problem and arrange a solution. Solutions may include
purchase of replacement parts or returning the unit to the factory for inspection and repair. All returns
require a Return Authorization number to be issued by Pulsafeeder. Parts purchased to correct a warranty
issue may be credited after an examination of original parts by Pulsafeeder. Warranty parts returned as
defective which test good will be sent back freight collect. No credit will be issued on any replacement
electronic parts.
Any modifications or out-of-warranty repairs will be subject to bench fees and costs associated with
replacement parts.

Safety Considerations:
1. Read and understand all related instructions and documentation before attempting to install or maintain
this equipment
2. Observe all special instructions, notes, and cautions.
3. Act with care and exercise good common sense and judgment during all installation, adjustment, and
maintenance procedures.
4. Ensure that all safety and work procedures and standards that are applicable to your company and facility
are followed during the installation, maintenance, and operation of this equipment.

Revision History:
Rev B (3-1-05)
- Update diagram fig. 10
- Revise text step 11b page 11 diaphragm removal and replacement
- Update all parts diagrams and lists, Section 12
Rev C (9-1-06)
- Update for Kynar (PVDF) heads

- Add model string ID page
- Update KOPkit list with PVDF kits
- Update parts lists with PVDF parts
Rev E (2-2007)
- Update all for introduction of model DC6, SPO address only
- Update materials references to “PTFE”

Copyright ©2004, 2006, 2007 Pulsafeeder, Inc. All rights reserved.
Information in this document is subject to change without notice. No part of this publication may be
reproduced, stored in a retrieval system or transmitted in any form or any means electronic or mechanical,
including photocopying and recording for any purpose other than the purchaser’s personal use without the
written permission of Pulsafeeder, Inc.

ii

Table of Contents
1. INTRODUCTION .....................................................................................................................................1
2. PRINCIPLES OF OPERATION ..................................................................................................................1
2.1

Reagent Head Assembly ........................................................................................................2

2.2

Control Assembly....................................................................................................................2

2.3

Gear Ratio Assembly ..............................................................................................................2

3. EQUIPMENT INSPECTION .......................................................................................................................3
4. STORAGE ……………………………………………………………………………………………………...3
5. INSTALLATION ......................................................................................................................................3
5.1

Location....................................................................................................................................3

5.2

Piping System ..........................................................................................................................4

5.3

Suction Pressure Requirements............................................................................................5

5.4

Discharge Pressure Requirements........................................................................................5

6. EQUIPMENT STARTUP ...........................................................................................................................6
6.1

Fastener Inspection.................................................................................................................6

6.2

Output Adjustment ..................................................................................................................6

6.3

Priming the Reagent Head......................................................................................................7

6.4

Calibration ................................................................................................................................8

7. M AINTENANCE ......................................................................................................................................9
7.1

Lubrication ...............................................................................................................................9

7.2

Wet End Removal, Inspection, & Reinstallation...................................................................10

7.3

Check Valves ...........................................................................................................................12

7.4

Motor Removal & Reinstallation ............................................................................................16

7.5

Gearset Removal .....................................................................................................................16

7.6

Gearset Replacement..............................................................................................................18

8. REPLACEMENT PARTS ..........................................................................................................................19
8.1

KOPkit Program.......................................................................................................................19

8.2

Ordering KOPkits or Parts......................................................................................................19

iii

8.3

KOPkit numbers by model: ....................................................................................................20

9. MODEL NUMBER IDENTIFICATION...........................................................................................................21
10. WET END M ATERIALS REFERENCE ........................................................................................................22
11. TROUBLESHOOTING ..............................................................................................................................23
12. PIPING ACCESSORIES ...........................................................................................................................25
13. DIMENSIONAL DRAWING........................................................................................................................26
14. PARTS DIAGRAMS AND PARTS LISTS .....................................................................................................28
14.1

Parts diagram, DC2 and 3 .......................................................................................................28

14.2

Bill of Materials, DC2...............................................................................................................29

14.3

Bill of Materials, DC3...............................................................................................................31

14.4

Parts Diagram, DC4, 5, and 6..................................................................................................34

14.5

Bill of Materials, DC4...............................................................................................................35

14.6

Bill of Materials, DC5...............................................................................................................37

14.7

Bill of Materials, DC6...............................................................................................................39

iv

1. Introduction
The OMNI® metering pump is positive displacement, mechanically operated reciprocating diaphragm
pump. Each pump consists of a power end and a process end separated by a PTFE faced diaphragm.
Individual pumps will vary in appearance due to various liquid ends and accessories; however, the basic
principles of operation remain the same.

2. Principles Of Operation

Figure 1, reagent head operation

A diaphragm reciprocates at a preset stroke length, displacing an exact volume of process fluid.
Diaphragm retraction causes the product to enter through the suction check valve. Diaphragm advance
causes the discharge of an equal amount of the product through the discharge check valve.

1

2.1

Reagent Head Assembly
The typical reagent head assembly consists of reagent head, diaphragm, and suction and discharge
cartridge check valves. This assembly is the only part of the pump to contact the process liquid;
consequently, maintenance is critical to pump performance.

2.2

Control Assembly
The OMNI® pump incorporates a lost motion style of stroke length adjustment to limit diaphragm
travel during the suction portion of each stroke. The stroke length setting is indicated by a (0% –
100%) scale located on the stroke adjustment assembly.
Stroke length is changed by loosening the locking screw and turning the hand knob. This turns a
mechanism, which limits rearward travel of the diaphragm. Refer to Section 6.2 for further
information.
For automatic flow rate control, users can consider the Pulsafeeder MPC speed based control system,
please contact your local Pulsafeeder dealer or representative for more information.

2.3

Gear Ratio Assembly
OMNI® pumps are driven by an electric motor mounted on the motor adaptor input flange. The
motor drives a set of worm gears that convert rotational speed into torque. They, in turn, power the
eccentric shaft assembly that converts rotary motion into reciprocating motion.

Figure 2, isometric view

2

3. Equipment Inspection
Check all equipment for completeness against the order and for any evidence of shipping damage.
Shortages or damage must be reported immediately to the carrier and your authorized representative or
distributor of OMNI® pumps.

4. Storage
4.1.1

Short Term
Storage of your OMNI® pump for up to 12 months is considered short-term. The recommended
short-term storage procedures are:
a) Store the pump indoors at room temperature in a dry environment.
b) If required by the operating environment, take precautions to prevent entry of water or humid air
into the eccentric enclosure.
c) Prior to startup, perform a complete inspection and then start up in accordance with instructions
in this manual.

4.1.2

Long Term
Every twelve months, in addition to the above short-term procedures, power up the motor and operate
the pump for a minimum of one hour. It is not necessary to have liquid in the reagent head during
this operation, but the suction and discharge ports must be open to atmosphere.
After twelve months of storage, Pulsafeeder’s warranty cannot cover items that are subject to
deterioration with age, such as seals, gaskets, and diaphragms. If the pump has been in storage longer
than 12 months it is recommended that these items be inspected and replaced as necessary prior to
startup. Materials and labor to replace this class of item under this circumstance are the purchaser’s
responsibility. Consult your local Pulsafeeder representative for assistance in obtaining parts and
service for your pump.

5. Installation
5.1

Location
When selecting an installation site or designing a chemical feed system, consideration should be given
to access for routine maintenance.
OMNI® pumps are designed to operate indoors and outdoors, but it is desirable to provide a hood or
covering for outdoor service. External heating is required if ambient temperatures below 0° C (32° F)
are anticipated, especially if pumps are not in continuous duty. Check with the factory if concerned
with the suitability of the operating environment.
The pump must be rigidly bolted to a solid and flat foundation to minimize vibration, which can loosen
connections. When the pump is bolted down, care must be taken to avoid distorting the base and
affecting alignments. The pump must be level within 5°. This will assure that the check valves can
operate properly.

3

5.2

Piping System
1. All systems should include a pressure relief valve on the discharge side, to protect piping and process
equipment, including the pump, from excess process pressures. An external relief valve is
required! There should be no devices capable of restricting flow (such as a valve) located between
the pump and the relief device.
2. Shutoff valves and unions (or flanges) on suction and discharge piping are recommended. This
permits check valve inspection without draining long runs of piping, making periodic maintenance
and inspection easier.
Shutoff valves should be of the same size as connecting pipe. Ball valves are preferred since they
offer minimum flow restriction.
3. Suction systems should include an inlet strainer, if appropriate for the product being pumped. Pump
check valves are susceptible to dirt and other solid contaminants, and any accumulation can cause
malfunction. The strainer should be located between the suction shutoff valve and the pump suction
valve. It must be sized to accommodate the flow rate and the anticipated level of contamination. A
100 mesh screen size is generally recommended.
4. Vacuum/pressure gauges in the suction and discharge lines are helpful in order to check system
operation. Gauges should be fitted with protective shutoff valves for isolation while not in use.
5. Piping weight must not be supported by valve housings or other portions of the reagent head, as the
resulting stresses can cause leaks. If appropriate, provide for thermal expansion and contraction so
that no excess force or moments are applied to the pump.
6. When making process connections, ensure that the check valve assemblies do not rotate as the
threaded connections are secured. It is critical, especially with plastic construction, that the check
valves not be too tight into the reagent head. The threaded connection between the check valve
assembly and the regent head uses on o-ring seal and does not require sealing tape or any other
sealant.
7. In piping assembly, use a sealing compound chemically compatible with the process material. Users
of sealing tape are cautioned to ensure that the entering pipe thread ends are not taped, and that tape is
removed from previously-used threads to the maximum practical extent prior to re-use. Both new and
existing piping should be cleaned, preferably by flushing with a clean liquid (compatible with process
material) and blown out with air, prior to connection to the pump. Debris from the piping system that
prevents proper check valve operation is a common startup issue.
8. Note that for pumps which utilize cartridge-type check valve assemblies, no thread tape or sealant is
required on the threads which secure the cartridge assembly to the pump reagent head. This area is
sealed with o-rings integral to the cartridge. Sealant on these threads can actually degrade sealing
capability.

4

5.3

Suction Pressure Requirements
Although OMNI® metering pumps have some suction lift capability, a flooded suction (i.e., suction
pressure higher than atmospheric pressure) is preferable whenever possible. The pump should be
located as close as possible to the suction side reservoir or fluid supply source.
For fluid with a vapor pressure of 5 psia or less (at operating temperature) the wet suction lift capability
is approximately ten (10) feet. If this requirement is not met, the pump will not provide reliable,
accurate flow. In suction lift conditions, the use of a foot valve is recommended at the lowest point of
the pickup tube or pipe. Pumps under suction lift conditions may require some liquid priming before
they will operate reliably.

5.4

Discharge Pressure Requirements
All OMNI® metering pumps are designed for continuous service at the rated discharge pressure. If
system suction pressure exceeds discharge pressure (a condition sometimes described as “pumping
downhill”), flow would be generated (siphoning) in addition to that caused by the pump. This results in
a reduction in accuracy and loss of control over the metering process. To prevent this flow-through
condition, the discharge pressure must exceed suction pressure by at least 0.35 Bar (5 psi). This can be
achieved where necessary by the installation of a backpressure valve in the discharge line. Conditions
where the actual discharge pressure exceeds the pump’s rating are to be avoided as they will cause
damage to the pump components.

Figure 3, sample system configuration
5

6. Equipment Startup
6.1

Fastener Inspection
All pump fasteners should be checked prior to pump operation, and occasionally during use. This
would include reagent head mounting bolts, motor mounting bolts, and the hardware that secures the
pump to its foundation. Most hardware can be checked simply to ensure it is not loose. However, utilize
the following values when checking reagent head bolt torque:

Model
DC2
DC3 and 4
DC5
DC6

6.2

Material
Plastic
Metal
Plastic
Metal
Plastic
Metal
Plastic
Metal

Reagent Head Bolt Torque
# Bolts and size
N-m
In. - Lbs
(4) M6 * 1.0
3.39
30
(4) M6 * 1.0
3.39
30
(4) M8 * 1.25
6.77
60
(4) M8 * 1.25
6.77
60
(6) M8 * 1.25
8.46
75
(6) M8 * 1.25
8.46
75
(6) M8 * 1.25
8.46
75
(6) M8 * 1.25
8.46
75

Output Adjustment
All OMNI® pumps have a hand wheel for manual stroke adjustment. The hand wheel can be adjusted to
any point from 0 to 100%. This value represents the stroke length setting and therefore the flow rate of
the pump relative to its maximum output.
1. Turn the red lock screw counterclockwise to release the
stroke lock. Making adjustments without releasing the
lock may damage the mechanism.
2. Adjust the hand wheel to the desired output.
a) The stroke barrel indicates stroke length in 20%
increments.
b) The hand wheel indicates stroke length in 1%
increments.
For example, to set the pump to 75% stroke length,
(starting from the factory default setting of 0%) turn the
hand wheel counter clockwise until he 60% indicator is
visible on the stroke barrel.
Continue the counter clockwise rotation until the hand
wheel indicator is at 15. Refer to Figure 4.
3. Turn the lock screw clockwise to lock the stroke adjustment
into position.
Adjustments can be made while the pump is at rest or
operating, although adjustments are easier to make
while the pump is in operation.

6

Figure 4, stroke adjustment

6.3

Priming the Reagent Head

1. When handling process liquids, follow all applicable personal and facility safety guidelines.
2. Ensure that the pump is ready for operation and that all process connections are secure.
3. Open the suction and discharge line shutoff valves.
4. If the piping system design and the storage tank are such that the product flows due to gravity through
the pump, reduce the discharge pressure and the system will self prime when the pump is started. In
the event the discharge line contains a significant amount of pressurized air or other gas, it may be
necessary to lower the discharge pressure to enable the pump to self-prime.
5. If the installation involves a suction lift, it may be necessary to prime the reagent head and suction
line. Operate the pump as in step 4 above, many times the pump will be capable of self priming. If it
does not begin to pump, remove the discharge valve assembly. Carefully fill the reagent head
through the discharge valve port with process (or compatible) liquid, and then reinstall the check
valve.
6. Start the pump at the zero stroke length setting and slowly increase the setting to 100 to prime the
pump. If this does not work, it will be necessary to fill the suction line.
7. Filling of the suction line will necessitate the use of a foot valve or similar device at the end of the
suction line so that liquid can be maintained above the reservoir level. Remove the suction valve
assembly, fill the line, replace the suction valve, then remove the discharge valve assembly and fill
the reagent head as described in Step (3) above. The pump will now self-prime when started up per
step (4) above. Use appropriate precautions if handling process fluid. Ensure that any other fluid
used for priming is compatible with the product that will be pumped.

Figure 5, process flow
7

6.4

Calibration

Figure 6, sample flow calibration curve
All metering pumps must be calibrated to accurately specify stroke length settings for required flow
rates.
A typical calibration chart is shown above. Although output is linear with respect to stroke length
setting, an increase in discharge pressure decreases output uniformly, describing a series of parallel
lines, one for each pressure (only two are shown).
The theoretical output flow rate at atmospheric discharge pressure is based on the displacement of the
diaphragm, stroke length and the stroking rate of the pump. With increasing discharge pressure there is
a corresponding decrease in output flow. Pumps are rated for a certain flow at a rated pressure (check
nameplate). Whenever possible, calibration should be performed under actual process conditions (i.e.,
the same or a similar process liquid at system operating pressure).
To construct a calibration chart, measure the flow rate several times at three or more stroke settings (i.e.,
25, 50, 75, and 100), plot these values on linear graph paper, and draw a best-fit line through the points.
For stable conditions, this line should predict settings to attain required outputs.
All users are encouraged to test the flow rate of their pump once installed in their system, to
ensure best accuracy and reliable operation.

8

7. Maintenance
BEFORE PERFORMING ANY MAINTENANCE REQUIRING REAGENT HEAD OR VALVE (WET END)
DISASSEMBLY, BE SURE TO RELIEVE PRESSURE FROM THE PIPING SYSTEM AND, WHERE
HAZARDOUS PROCESS MATERIALS ARE INVOLVED, RENDER THE PUMP SAFE TO PERSONNEL
AND THE ENVIRONMENT BY CLEANING AND CHEMICALLY NEUTRALIZING AS APPROPRIATE.
WEAR PROTECTIVE CLOTHING AND EQUIPMENT AS APPROPRIATE.
Accurate records from the early stages of pump operation will indicate the type and levels of required
maintenance. A preventative maintenance program based on such records will minimize operational
problems. It is not possible to forecast the lives of wetted parts such as diaphragms and check valves.
Since corrosion rates and operational conditions affect functional material life, each metering pump must
be considered according to its particular service conditions.
The OMNI® KOPkit will contain all replacement parts normally used in a preventative maintenance
program. It is recommended that KOPkits and PULSAlube grease be kept available at all times.

7.1

Lubrication
OMNI® pumps are supplied completely lubricated from the factory. For optimum pump performance
under normal conditions, gear grease should be redistributed every 1500 hours. For severe service in
extreme temperatures or very dirty environments, this interval may be shorter.
1. Disconnect the power source to the drive motor, and relieve all pressure from the piping system.
2. Remove the side cover from the pump. Refer to Figure 7.
3. Redistribute grease onto gear and worm teeth. On DC2 and 3 pumps, force grease into the hole in the
end of the gear shaft using a screwdriver or putty knife. Primary lubrication points are called out in
Figure 7, below.
4. Replace the side gasket and cover.

Figure 7, gearset lubrication points
9

7.2

Wet End Removal, Inspection, & Reinstallation
IF THE DIAPHRAGM HAS FAILED, PROCESS FLUID MAY HAVE CONTAMINATED THE PUMP
ECCENTRIC HOUSING (ALTHOUGH NORMALLY, ANY PROCESS FLUID BEHIND A FAILED
DIAPHRAGM WOULD PASS THROUGH THE BOTTOM DRAIN HOLE). HANDLE WITH APPROPRIATE
CARE.

Figure 8, wet end components
OMNI® diaphragms do not have a specific cycle life; however, the accumulation of foreign material
or debris sufficient to deform the diaphragm can eventually cause failure. Failure can also occur as a
result of system over pressure or chemical attack. Periodic diaphragm inspection and replacement are
recommended. Each user should perform regular inspections to determine the replacement interval
that is appropriate to their system conditions.

10

7.2.1

Diaphragm Removal & Reinstallation
1. Adjust the stroke setting to 50% and disconnect the power source to the drive motor.
2. Relieve all pressure from the piping system.

Take all precautions described under the WARNING on page 9, Section 7 to prevent environmental
damage and exposure of personnel to hazardous materials.

3. Close the inlet and outlet shutoff valves.
4. Place a pan underneath the pump head adaptor to catch any liquid leakage.
5. Disconnect piping to the reagent head and drain any process liquid, following material safety
precautions described.
6. Remove all but one top reagent head bolt. Product will leak out between the pump head adaptor and
reagent head as the bolts are loosened.
7. Tilt the head and pour out any liquids retained by the check valves into a suitable container,
continuing to follow safety precautions as appropriate.
8. Remove the final bolt and rinse or clean the reagent head with an appropriate material.
9. Remove the diaphragm by turning it counter-clockwise.
10. Inspect the diaphragm. The diaphragm must be replaced if it is cracked, separated, or obviously
damaged.
11. Install the diaphragm.
a) Ensure that the critical sealing areas of diaphragm, reagent head, and pump head are clean and
free of debris.
b) Lubricate the elastomer side of the diaphragm liberally, where it is in contact against the pump
head and deflection plate. Use a silicone grease or silicone-based o-ring lubricant.
12. Thread the diaphragm (clockwise) fully onto the shaft.
When reinstalling a used diaphragm it is not necessary to maintain the previous orientation relative to
the reagent head or pump head hole pattern.
13. Install the reagent head bolts and tighten in an alternating pattern to ensure an even seating force.
Torque to the values recommended in Section 6.1.
14. Re-prime the pump following the procedure outlined in Section 6.3.

11

7.3
7.3.1

Check Valves
General Description
Most fluid metering problems are related to check valves. Problems usually stem from solids
accumulation between valve and seat, corrosion of seating surfaces, erosion, or physical damage due
to wear or the presence of foreign objects.
The valve incorporates a ball, guide, and seat. Flow in the unchecked direction lifts the ball off the
seat, allowing liquid to pass through the guide. Reverse flow forces the ball down, sealing it against
the sharp edge of the seat. The guide permits the ball to rotate but restricts vertical and lateral
movement in order to minimize “slip” or reverse flow. Ball rotation prolongs life by distributing
wear over the entire surface of the ball. Since ball return is by gravity, the valve must be in the
vertical position in order to function properly. Parts are sealed by “O”-rings.
All OMNI models with the exception of the DC5 and 6 in metal construction utilize a convenient
cartridge-type check valve. All check components are pre-assembled and the cartridge should be
replaced as a unit. When replacing, note that valves are marked with the flow direction, as the suction
and discharge configurations are different.
OMNI DC5 and 6 models supplied with metal (316ss) reagent head construction utilize a multi-part
check valve assembly, secured to the reagent head with a tie-bar clamping arrangement. These utilize
the same components (seat, ball, and guide) and operate in the same manner as the cartridge type.

Figure 9, check valves, DC2

Check Valve
Discharge Position

Check Valve
Suction Position

Figure 9, check valves DC2

12

Check Valve
Suction Position

Check Valve
Discharge Position

Figure 10, check valves, DC3 and DC 4

Check Valve
Suction Position

Check Valve
Discharge Position

Figure 11, check valves, DC5 and DC6 plastic construction

13

7.3.2

Check Valve Removal & Reinstallation, Cartridge type
Valving that is of the cartridge design is intended to be replaced as an assembly.
15. Disconnect the power source to the drive motor.
16. Relieve all pressure from the piping system.
17. Take all precautions necessary to prevent contamination to the environment and personnel exposure
to hazardous materials.
18. Close the inlet and outlet shutoff valves.
19. Disconnect the suction piping at the installed union near the suction port.
20. Loosen and remove the suction valve cartridge slowly to drain any liquid from the reagent head.
21. Disconnect the discharge piping at the installed union near the discharge port.
22. Loosen and remove the discharge valve cartridge slowly to drain any trapped liquid.
23. Reinstall both new valve assemblies, taking care to ensure that they are in the correct ports.
Lettering on the side of each valve should be right side up when assembled to the pump. Each valve
assembly should also have an arrow, which should indicate direction of flow (upwards). Do not coat
the threads of the cartridge vale with a pipe sealant. Each valve cartridge should be tightened only
until the o-ring seal makes good contact with the reagent head surface. Over-tightening will cause
damage and lead to leaks
24. Reinstall both suction and discharge piping. Secure the cartridge while making your external
connections to prevent rotating the cartridge and over-tightening it into the pump.

7.3.3

Check Valve Removal & Reinstallation, Tie-bar type
1. Disconnect the power source to the drive motor.
2. Relieve all pressure from the piping system.
3. Take all precautions necessary to prevent contamination to the environment and personnel exposure
to hazardous materials.
4. Close the inlet and outlet shutoff valves.
5. Loosen the suction valve tie-bar bolts (4) and spring the suction piping slightly away from the head,
allowing liquid to drain. It may be necessary to loosen a union or flange.
6. Remove the suction check valve assembly by sliding it towards you, holding it together as a unit.
Note carefully the position of the component parts, to assist in re-assembly.
7. Loosen the discharge valve tie-bar bolts (4) and spring the discharge piping slightly away from the
head, allowing liquid to drain. It may be necessary to loosen a union or flange.
8. Remove the discharge check valve assembly by sliding it towards you, holding it together as a unit.
Note carefully the position of the component parts, to assist in re-assembly.
9. Disassemble both valves and check components for wear or damage. The seats should have a sharp
edge and be free from dents or nicks. Hold a ball firmly against the seat in front of a bright light and
inspect for fit, observation of light between the ball and seat is cause for replacement.
10. Reassemble both valves using new parts as required. Sealing o-rings should always be replaced.
11. Replace both valve assemblies onto the pump, taking care to ensure they are oriented correctly, with
the balls above the seats, and the seats oriented with the sharp edge up and the chamfered edge down.
14

Inserting the check valve assmbly into the pump in the wrong directiom, or having the check seat
upside down, will prevent proper seals at the o-rings, decrease pump performance, and can cause
damage to the diaphragm.
12. Carefully make sure that the check assemblies are in proper position, and tighten the four tie-bar
bolts, using a star pattern, to a torque of 6 Ft-lbs (8 N-m).
13. Retighten any unions, flanges, or other process connections that may have been loosened previously.

Figure 12, DC5 and 6 check valves, metal construction

15

7.4

Motor Removal & Reinstallation
1. Disconnect the power source to the drive motor.
2. Disconnect the motor wiring from the motor.
3. Remove the four bolts retaining the motor to the motor adaptor.
The motor shaft fits into a bore on the pump input shaft.
4. Slide the motor shaft out of the pump input shaft.
Be careful not to lift the pump input shaft up out of the pump.
5. Apply a lubricant such as Loctite™ Silver Grade® Anti-seize paste
(or similar) to the motor shaft and key before reassembling..
6. Reinstall the motor by sliding the motor shaft into the pump input
shaft.
7. Insert and tighten the four bolts removed in step 3.
8. Reconnect the motor wiring to the motor.
9. Connect power to the drive motor.
Figure 13, motor mounting

Motor rotation must be wired for CW rotation, as viewed from the top of the motor, as noted by the
arrow on the top of the pump housing.

7.5

Gearset Removal
Gearset diagram is on following page
1.
2.
3.
4.

Disconnect power source and wiring from the motor.
Set stroke adjustment to zero.
Remove motor from the pump (refer to Section 7.4).
Remove the four socket head screws (Item 1) that attach the motor adaptor (Item 2) to the
pump housing and remove the adaptor.
5. Loosen and remove the Hex Head Bolts (Item 5), and remove the pump side cover (Item 6)
and gasket (Item 7).
6. Remove the Worm Shaft Assembly (item 4) by carefully pulling it straight up out of the
pump housing. On DC2 and DC3 models, be careful not to lose the lower thrust bearing
and washers (items 11 and 12).

16

Figure 14, gearset components
7. Loosen the set screw (Item 9) on the worm gear (Item 8) and remove it along with its
shaft key (Item 10).
If you have the DC2 or 3 models go to step 8. If you have the DC4, 5, or 6 models go to
step 9.
8. Remove the Thrust Washers and Bearing
(Item 11 & 12) from the housing.
If the Thrust Washers show signs of
excessive wear or scoring, replace them
during re-assembly.
9. Clean grease from the gear cavity.
10. Examine the Worm Shaft Grease Seal
(Item 3) in the pump housing on the DC
2 and 3 model or in the motor adaptor on
the DC 4, 5, and 6 models.
If the Grease Seal shows excessive wear
or damage, replace it during re-assembly.

Figure 15, worm shaft

17

7.6

Gearset Replacement
1. Apply PULSAlube grease # NP980006-000 to both sides of the thrust washer and install onto the
eccentric shaft.
On the DC4, 5, and 6 models, the washer fits into a shallow counter-bore.
2. Assemble Worm Gear (Item 8) and key (Item 10) to the eccentric shaft. Do not tighten the setscrew
yet.
3. Thread the M6-1.0 screw into the threaded hole in the end of the eccentric shaft. Tighten the Worm
Gear set screw while simultaneously pulling on the screw in the end of the shaft in order to eliminate
any endplay in the eccentric shaft.
4. Rotate the Worm Gear
It should turn easily with no perceptible endplay.
5. Remove the screw that was inserted in the shaft in step 3.
6. Assemble and install the worm shaft assembly
a) If you have a DC2 or 3 model:
Apply PULSAlube grease # NP980006-000 to the two lips of the worm shaft seal.
Apply PULSAlube grease # NP980006-000 to the small end of the worm shaft.
Carefully insert the worm shaft into the pump housing.
Assemble the lower thrust bearing (with a washer on each side) into the shallow counter bore in
the bottom of the housing cavity.
Fit the shaft into the bearing in the housing.
b) If you have a DC4, 5, or 6 model:
Apply PULSAlube grease # NP980006-000 to the small end of the worm shaft.
Insert the worm shaft into the pump housing, fitting the end of the shaft into the bearing in the
housing.
Apply PULSAlube grease # NP980006-000 to the two lips of the seal.
Assemble the adapter to the pump housing while carefully slipping the seal over the worm shaft.
7. Fill the gear cavity completely with PULSAlube grease # NP980006-000 and reassemble the pump
side cover and gasket.
8. Reassemble the motor to the pump. Verify that motor rotation is clockwise when viewed from the
top.
9. Reinstall the pump in the system and restart the pump (refer to Section 6 – Startup).

18

8. Replacement Parts
8.1

KOPkit Program
OMNI® KOPkits contain all replacement parts normally used in a preventative maintenance program.
(PULSAlube grease is also available separately for preventative maintenance programs. Refer to
Section 6 – Equipment Startup). There is a specific KOPkit for every OMNI® pump model. Each
KOPkit is vacuum-packed for extended storage. All OMNI® pumps have the KOPkit number identified
on the pump nameplate and Pulsafeeder order documents. KOPkits can also be selected from the
technical data sheet shipped with the pump or by a Pulsafeeder representative. A list of the OMNI
KOPkit numbers can also be found on the next page. The kit is identified by the model number of the
pump, the wetted end material, and the process connection thread type. For models with tie-bar type
check valves, the appropriate components (check valve balls, seats, and o-rings) are supplied instead of
the cartridges pictured.

Figure 16, KOPkit parts

8.2

Ordering KOPkits or Parts
When ordering replacement parts always specify:
•
•

Pump model and serial number (from pump nameplate), e.g., Model No. (DC-2) with Serial No.
F406365-3.
Part number and description from the OMNI® parts list. Include the three-character suffix. (Note:
OMNI part numbers begin either with the letters NP, or the letter W, e.g., NP170001-THY or
W210221-001.)

19

8.3

KOPkit numbers by model:
Pump Model

Wetted Material

Connection Type

KOPkit number

DC2

PVDF

NPT

NLK020FP

DC3 or DC4

PVDF

NPT

NLK040FP

DC3 or DC4

PVDF

ISO 7-1

NLK040FB

DC5 or DC6

PVDF

NPT

NLK050FP

DC5 or DC6

PVDF

ISO 7-1

NLK050FB

DC7

PVDF

n/a

NLK070FX

DC5 or DC6

Polypropylene

NPT

NLK050PP

DC5 or DC6

Polypropylene

ISO 7-1

NLK050PB

DC7

Polypropylene

n/a

NLK070PX

DC2

316

NPT

NLK020AP

DC3 or DC4

316

NPT

NLK040AP

DC3 or DC4

316

ISO 7-1

NLK040AB

DC5 or DC6

316

NPT

NLK050AP

DC5 or DC6

316

ISO 7-1

NLK050AB

NPT

NLK060HX ( 1 )

ISO 7-1

NLK060HX ( 1 )

(2)

DC6

HSO

DC6

HSO ( 2 )

NOTES:

(1) “HSO” construction refers to the recommended materials for handling Sulfuric Acid at high
concentrations (above 95%). This configuration consists of 316ss for the reagent head, the
valve guide, and the process connection. Alloy-20 is supplied for the check valve seats,
and Hastelloy-C is supplied for the check valve balls. HS0 configuration is supplied only
as a KOPkit and not as an original pump configuration.
(2) PVC wet end material has been discontinued, use PVDF (Kynar®) parts as a direct
replacement for these pumps.
(3) DC7 model is covered in a separate publication

20

9. Model Number Identification
Position

Sample

1 and 2

DC

3 and 4

3B

Specifies

Options
DC = OMNI model pump

Size/Flow

2 / 3 / 4 / 5 / 6 – diaphragm diameter
A / B / C / D – stroking rate
See sales literature for flow/pressure ratings

5

X

6

F

7

P

8

-*

9

Option *

MPC control

M – indicates supplied with MPC controller

10

Option *

Input voltage

1 – 115V 60 Hz
2 – 230V 60 Hz
3 – 110V 50 Hz
4 – 220V 50 Hz

11

Option *

Remote cable

X – standard length remote at pump
C – extended cable length

12

Option *

Language

Motor frame
and size

1 – ½ Hp, 1 pH 115/230V, 71 frame
2 – ½ Hp, 1 pH, 115/230V, 56 frame
3 – ½ Hp, 3 pH, 230/380V, 71 frame
4 – ½ Hp, 3 pH, 230/380/460V, 56 frame
5 – MPC control with 56 frame motor
6 – MPC control, NO motor, 56 frame
7 – MPC control with 71 frame motor
8 – MPC control, NO motor, 71 frame
X – no motor, set up for 56 frame
Y – no motor, set up for 71 frame

Wetted materials F – PVDF, PTFE o-rings, ceramic ball
E – PVC (note - obsolete)
A – 316ss, PTFE o-rings
P - Polypropylene, DC 5 and 6 only
Connections

P – NPT
B – ISO 7-1 (not available on DC2)
position 8 is a dash

E – English
F - French
S - Spanish
G - German

* - If no MPC controller is ordered, the model string ends at position 7. Positions 8 through 12 are
not entered for a pump without the MPC.

21

10. Wet End Materials Reference
Wet End
Configuration

PVDF
®
(Kynar )

Model

Connection

DC2
DC3
DC4
DC5
DC6

1/4" NPT

DC7

PP
(Polypropylene)

DC2
DC3
DC4
DC5
DC6
DC7

SS
(316)

DC2
DC3
DC4
DC5
DC6
DC7

Head

Guide

1/2" NPT or ISO 7-1
1" NPT or ISO 7-1

Sealing
O-rings

PTFE
PVDF

PVDF

1 1/2" NPT & ANSI
Flange and
1 1/2" DIN40 Flange

®

Viton

Seat Oring

PVDF

n/a

PVDF (oring seat)

Viton

PP

n/a

PP (o-ring
seat)

Viton

®

(1)

n/a

1" NPT or I ISO 7-1

PTFE
PP

PP

Ceramic
Viton

1/4" NPT
1/2" NPT or ISO 7-1

Seats

Ceramic

n/a

1 1/2" NPT & ANSI
Flange and
1 1/2" DIN40 Flange

Balls

SS

SS

PTFE

Ceramic

PTFE

SS

SS

1" NPT or ISO 7-1

n/a

n/a

(1) DC7 check valve seats incorporate an o-ring seal
DC7 model is covered in a separate publication
n/a = materials not available in this pump size or component not used on this model

22

®

(1)

n/a

11. Troubleshooting
Difficulty
Pump does not start

No delivery

Probable Cause
Faulty power source.
Blown fuse, circuit breaker.
Broken wire.
Wired improperly.
Process piping blockage.
Motor not running.
Supply tank empty.
Lines clogged.
Closed line valves.
Ball check valves held open with solids.
Vapor lock, cavitation.
Prime lost.
Strainer clogged.

Low delivery

Stroke adjustment set at zero.
Motor speed too low

Check valves worn or dirty
Calibration system error
Product viscosity too high

Delivery gradually
drops.

Delivery erratic.

Delivery higher than
rated.

Product cavitating
Check valve leakage.
Leak in suction line.
Strainer fouled.
Product change.
Supply tank vent plugged.
Leak in suction line.
Product cavitating.
Entrained air or gas in product.
Motor speed erratic.
Fouled check valves.
Inadequate backpressure

Suction pressure higher than discharge
pressure.
Back pressure valve set too low.
Back pressure valve leaks.

23

Remedy
Check power source.
Replace - eliminate overload.
Locate and repair.
Check diagram.
Open valves, clear other obstructions.
Check power source. Check wiring
diagram (see above).
Fill tank.
Clean and flush.
Open valves.
Clean – inspect, flush with clear fluid.
Increase suction pressure.
Re-prime, check for leak.
Remove and clean. Replace screen if
necessary.
Increase stroke length setting.
Check voltages, frequency, wiring, and
terminal connections. Check nameplate
vs. Specifications.
Clean, replace if damaged
Evaluate and correct
Lower viscosity by increasing product
temperature or dilution. Increase pump
and/or piping size
Increase suction pressure.
Clean, replace if damaged.
Locate and correct.
Clean or replace screen.
Check viscosity and other variables.
Unplug vent.
Locate and correct.
Increase suction pressure.
Consult factory for suggested venting.
Check voltage and frequency.
Clean, replace if necessary.
Increase discharge pressure to obtain a
minimum pressure difference of 5 pis
from suction to discharge
Install backpressure valve or consult
factory for piping recommendations.
Increase setting.
Repair, clean, or replace.

Difficulty
Noisy gearing,
knocking

Probable Cause
Discharge pressure too high.
Water hammer.
Stroke length at partial setting.

Piping noisy.

Low grease level.
Pipe size too small.

Motor overheats.

Pipe runs too long.
Pulsation dampener inoperative or
flooded.
No surge chamber or dampener used.
Pump overloaded.
High or low voltage.
Loose wire.
Incorrect motor wiring

24

Remedy
Reduce pressure.
Install pulsation dampener.
Some operating noise is characteristic of
lost motion pumps.
Add or replace grease.
Increase size of piping - install pulsation
dampener.
Install pulsation dampener in line.
Refill with air or inert gas. Inspect and
replace diaphragm and recharge.
Install pulsation dampeners.
Check operating conditions against pump
design. Verify discharge pressure
Check power source.
Trace and correct.
Verify and correct

12. Piping Accessories
Pressure Relief Valves
Pressure relief valves are designed to protect chemical feed systems from damage that may be caused by
defective equipment or a blockage in the discharge line. These valves function to limit the pressure
downstream of the pump. Field adjust the pressure relief valve to operate when the discharge pressure
exceeds operating pressure by 10-15%. Pressure relief valve should always be adjusted to a setting below
the maximum rated pressure of the pump. No potentially restrictive components, such as a valve, should
be installed between the pump discharge and the PRV.
Diaphragm Backpressure Valve
A diaphragm backpressure valve creates constant back pressure. A PTFE or PTFE-faced diaphragm
offers maximum chemical protection and service life, and seals spring and bonnet from product.
Be sure to install with fluid flow in direction of arrow on valve body.

Pulsation Dampener
A pulsation dampener is a pneumatically charged diaphragm-type chamber that intermittently stores
hydraulic energy. Used on the inlet, it can improve NPSHA (Net Positive Suction Head available)
characteristics of the suction piping system. On the discharge line it will reduce discharge pressure and
pulsating flow variations.

25

13. Dimensional Drawing

Letters reference dimensional table on next page

26

Dimension table in inches / mm
Letter references to diagram, previous page
“PP” = Polypropylene wetted material
“SS” = Stainless steel wetted material
Dimensions are with standard IEC 71 B14 frame motor

DC2

A
1.0 / 25.4

B
0.7 / 18.0

Dimension
C
6.9 / 175.3

DC3

1.0 / 25.4

0.7 / 18.0

6.9 / 175.3

4.5 / 113.5

1.5 / 38.1

DC4

2.0 / 50.8

0.9 / 22.4

7.6 / 193.0

5.1 / 130.2

1.8 / 44.5

DC5 – PP/PVDF

2.0 / 50.8

0.9 / 22.4

7.6 / 193.0

5.1 / 130.2

1.8 / 44.5

DC5 – SS

2.0 / 50.8

0.9 / 22.4

7.6 / 193.0

5.1 / 130.2

1.8 / 44.5

DC6 – PP/PVDF

2.0 / 50.8

0.9 / 22.4

7.6 / 193.0

5.1 / 130.2

1.8 / 44.5

DC6 - SS

2.0 / 50.8

0.9 / 22.4

7.6 / 193.0

5.1 / 130.2

1.8 / 44.5

I
1.8 / 46.7

J
5.7 / 145.3

Model

D
4.5 / 113.5

E
1.5 / 38.1

DC2

F
2.9 / 72.4

G
7.4 / 188.7

Dimension
H
13.6 / 347.6

DC3

3.3 / 83.6

7.4 / 188.7

14.6 / 370.2

1.8 / 46.7

5.7 / 145.3

DC4

3.4 / 85.5

8.4 / 213.9

15.4 / 392.4

2.5 / 63.5

6.9 / 175.5

DC5 – PP/PVDF

3.6 / 90.4

8.4 / 213.9

15.8 / 402.0

2.5 / 63.5

6.9 / 175.5

DC5 – SS

3.6 / 90.4

8.4 / 213.9

15.8 / 402.0

2.5 / 63.5

6.9 / 175.5

DC6 – PP/PVDF

3.6 / 90.4

8.4 / 213.9

15.8 / 402.0

2.5 / 63.5

6.9 / 175.5

DC6 - SS

3.6 / 90.4

8.4 / 213.9

15.8 / 402.0

2.5 / 63.5

6.9 / 175.5

Model

DC2

K
14.5 / 367.5

L
7.7 / 196.3

Dimension
M
3.9 / 98.2

DC3

14.5 / 367.5

8.9 / 226.1

4.5 / 113.0

DC4

15.7 / 397.8

8.9 / 226.1

4.5 / 113.0

DC5 – PP/PVDF

15.7 / 397.8

13.8 / 350.5

6.9 / 175.3

DC5 – SS

15.7 / 397.8

12.6 / 320.0

6.3 / 160.0

DC6 – PP/PVDF

15.7 / 397.8

15.3 / 387.3

7.6 / 193.7

DC6 – SS

15.7 / 397.8

14.1 / 356.9

7.1 / 178.5

Model

27

14. Parts Diagrams and Parts Lists
14.1 Parts diagram, DC2 and 3

28

14.2 Bill of Materials, DC2
ITEM
1

DESCRIPTION
SUPPORT PLATE

QTY
1

PART NUMBER
NP140054-BRS
NP170030-THY

2

DIAPHRAGM

1

3

REAGENT HEAD PVDF

1

NP160076-PVD

3

REAGENT HEAD PVC (obsolete)

1

NP160054-PVC

3

REAGENT HEAD 316

1

NP160054-316

4

BOLT

4

NP990420-188

5

FLT WASHER

4

NP991017-188

6

DC2 SPOOL ADAPTOR

1

NP140067-ALU

7

VLV ASSY PVDF

1

L3200TC4-PVD

7

VLV ASSY PVC

NPT

DISCHARGE (obs)

1

L3200TC4-PVC

7

VLV ASSY 316

NPT

DISCHARGE

1

L3200TC4-316

8

VLV ASSY PVDF

NPT

SUCTION

1

L3100TC4-PVD

8

VLV ASSY PVC

NPT

SUCTION (obs)

1

L3100TC4-PVC

8

VLV ASSY 316

NPT

SUCTION

1

L3100TC4-316

9

RETURN SPRING

1

NP430033-000

10

BOTTOM COVER

1

NP250084-000

11

BOTTOM COVER SCREW

4

NP992216-STL

12

STRADDLE ASSEMBLY

1

NP410066-000

13

BEARING

1

NP400037-000

14

ECCENTRIC

1

NP070022-000

15

BEARING

1

NP400041-000

16

THRUST WASHER

2

NP470033-000

17

WORM

11:1

1

W206961-000

17

WORM

20:1

1

W056965-000

17

WORM

40:1

1

W047022-000

18

SCREW

1

W770013-000

19

GASKET

1

NP460045-000

20

SIDE COVER

1

NP250060-STL

21

BOLT

4

NP990414-188

22

GEAR

11:1

1

W206446-011

22

GEAR

20:1

1

W206446-020

22

GEAR

40:1

1

W206446-040

23

THRUST WASHER

1

NP470029-000

24

ECCENTRIC SHAFT

1

NP410054-000

25

BEARING

2

NP400039-000

26

STRK ADJ ASSEMBLY

1

NP260013-000

27

KNOB

1

NP260001-GPC

28

KNOB COVER

1

NP250061-000

29

SCREW

1

W771001-010

30

LABEL

1

NP550084-000

31

WASHER

1

W771006-STL

32

MOTOR ADAPT ASSY 56C

1

NP490030-000

32

MOTOR ADAPT ASSY 71

1

NP490029-000

33

WORM SHAFT ASSY 56C

1

NP060031-A00

33

WORM SHAFT ASSY IEC71

1

NP060031-D00

34

DC2/3 GEARBOX

1

NP010024-ALU

NPT

DISCHARGE

29

35

NAME TAG

1

NP550130-000

36

NAME TAG SCREW

4

W771000-188

38

SET SCREW

2

W771004-022

39

NEEDLE BEARING

1

NP400046-000

40

KEY-WORM GEAR

1

W773097-004

41

ECCENTRIC SPACER

1

NP470031-000

42

GASKET

1

NP460047-000

43

SCREW

2

NP990008-STA

44

OIL SEAL

1

NP450029-000

45

PIPE PLUG

1

W772565-STL

46

WASHER

1

W774034-STL

47

SPOOL ADAPTOR BOLT

4

W770534-STL

48

SPOOL ADAPTOR WASHER

4

NP991018-188

49

RETAINING RING 71 FRAME

1

NP999041-000

50

RETAINER 71 FRAME

1

NP470041-STL

50

RETAINER 56C FRAME

1

NP410075-000

51

RETAINING RING 71 FRAME

1

NP999042-000

51

RETAINING RING 56C FRAME

1

NP999032-000

30

14.3 Bill of Materials, DC3
ITEM
1

DESCRIPTION
SUPPORT PLATE

QTY
1

PART NUMBER
NP140055-BRS
NP170031-THY

2

DIAPHRAGM

1

3

REAGENT HEAD PVDF

1

NP160077-PVD

3

REAGENT HEAD PVC (obsolete)

1

NP160055-PVC

3

REAGENT HEAD 316

1

NP160055-316

4

BOLT

4

NP990436-188

5

FLT WASHER

4

NP991018-188

6

DC3 SPOOL ADAPTOR

1

NP140068-ALU

7

VALVE DISCHARGE

1

NP32BVC8-PVD

7
7

PVDF

ISO 7-1

VALVE, DISCHARGE,

316,

ISO 7-1

1

NP32BAA8-316

VALVE, DISCHARGE,

PVC,

ISO 7-1 (obs)

1

NP32BVC8-PVC

7

VALVE DISCHARGE

PVDF

NPT

1

NP32PVD8-PVD

7

VALVE, DISCHARGE,

316,

NPT

1

NP32PAA8-316

7

VALVE, DISCHARGE,

PVC,

NPT (obs)

1

NP32PVC8-PVC

8

VALVE, SUCTION,

PVDF

ISO 7-1

1

NP31BVC8-PVD

8

VALVE, SUCTION,

316,

ISO 7-1

1

NP31BAA8-316

8

VALVE, SUCTION,

PVC,

ISO 7-1 (obs)

1

NP31BVC8-PVC

8

VALVE , SUCTION,

PVDF

NPT

1

NP31PVD8-PVD

8

VALVE, SUCTION,

316,

NPT

1

NP31PAA8-316

8

VALVE, SUCTION,

PVC,

NPT (obs)

1

NP31PVC8-PVC

9

RETURN SPRING

1

NP430033-000

10

BOTTOM COVER

1

NP250084-000

11

BOTTOM COVER SCREW

4

NP992216-STL

12

STRADDLE ASSEMBLY

1

NP410066-000

13

BEARING

1

NP400037-000

14

ECCENTRIC

1

NP070022-000

15

BEARING

1

NP400041-000

16

THRUST WASHER

2

NP470033-000

17

WORM

11:1

1

W206961-000

17

WORM

20:1

1

W056965-000

17

WORM

40:1 (obsolete)

1

W047022-000

18

SCREW

1

W770013-000

19

GASKET

1

NP460045-000

20

SIDE COVER

1

NP250060-STL

21

BOLT

4

NP990414-188

22

GEAR

11:1

1

W206446-011

22

GEAR

20:1

1

W206446-020

22

GEAR

40:1 (obsolete)

1

W206446-040

23

THRUST WASHER

1

NP470029-000

24

ECCENTRIC SHAFT

1

NP410054-000

25

BEARING

2

NP400039-000

26

STRK ADJ ASSEMBLY

1

NP260013-000

27

KNOB

1

NP260001-GPC

28

KNOB COVER

1

NP250061-000

29

SCREW

1

W771001-010

30

LABEL

1

NP550084-000

31

31

WASHER

1

W771006-STL

32

MOTOR ADAPT ASSY 56C

1

NP490030-000
NP490029-000

32

MOTOR ADAPT ASSY 71

1

33

WORM SHAFT ASSY 56C

1

NP060031-A00

33

WORM SHAFT ASSY IEC71

1

NP060031-D00

34

DC2/3 GEARBOX

1

NP010024-ALU

35

NAME TAG

1

NP550130-000

36

NAME TAG SCREW

4

W771000-188

38

SET SCREW

2

W771004-022

39

NEEDLE BEARING

1

NP400046-000

40

KEY-WORM GEAR

1

W773097-004

41

ECCENTRIC SPACER

1

NP470031-000

42

GASKET

1

NP460047-000

43

SCREW

2

NP990008-STA

44

OIL SEAL

1

NP450029-000

45

PIPE PLUG

1

W772565-STL

46

WASHER

1

W774034-STL

47

SPOOL ADAPTOR BOLT

4

W770534-STL

48

SPOOL ADAPTOR WASHER

4

NP991018-188

49

RETAINING RING 71 FRAME

1

NP999041-000

50

RETAINER 71 FRAME

1

NP470041-STL

50

RETAINER 56C FRAME

1

NP410075-000

51

RETAINING RING 71 FRAME

1

NP999042-000

51

RETAINING RING 56C FRAME

1

NP999032-000

32

This page intentionally left BLANK

33

14.4 Parts Diagram, DC4, 5, and 6

34

14.5 Bill of Materials, DC4
ITEM

DESCRIPTION

QTY
1

PART NUMBER

1

SUPPORT PLATE

2

DIAPHRAGM

1

NP170031-THY

3

REAGENT HEAD PVDF

1

NP160077-PVD

3

REAGENT HEAD PVC (obsolete)

1

NP160055-PVC

3

REAGENT HEAD 316

1

NP160055-316

4

BOLT

4

NP990436-188

5

FLT WASHER

7

VLV/CONN ISO 7-1 PVDF

7

VLV/CONN ISO 7-1 316

DISCHARGE

1

NP32BAA8-316

7

VLV/CONN ISO 7-1 PVC

DISCHARGE (obs)

1

NP32BVC8-PVC

7

VLV/CONN NPT

PVDF

DISCHARGE

1

NP32PVD8-PVD

7

VLV/CONN NPT

316

DISCHARGE

1

NP32PAA8-316

7

VLV/CONN NPT

PVC

DISCHARGE (obs)

1

NP32PVC8-PVC

8

VLV/CONN ISO 7-1 PVDF

1

NP31BVC8-PVD

8

VLV/CONN ISO 7-1 316

1

NP31BAA8-316

8

VLV/CONN ISO 7-1 PVC

SUCTION (obs)

1

NP31BVC8-PVC

8

VLV/CONN NPT

PVDF

SUCTION

1

NP31PVD8-PVD

8

VLV/CONN NPT

316

SUCT

1

NP31PAA8-316

8

VLV/CONN NPT

PVC

SUCT (obs)

1

NP31PVC8-PVC

9

RETURN SPRING

1

NP430034-000

10

BOTTOM COVER

1

NP250085-000

11

BOTTOM COVER SCREW

4

NP992216-STL

12

STRADLE ASSEMBLY

1

NP410067-000

13

BEARING

1

NP400038-000

14

ECCENTRIC

1

NP070023-000

15

BEARING

1

NP400042-000

16

DC4 SPOOL ADAPTOR

1

NP140068-ALU

17

WORM

8:1

1

W208764-008

17

WORM

10:1

1

W208764-010

17

WORM

15:1

1

W208764-015

17

WORM

30:1 (obsolete)

1

W208764-030

18

SCREW

1

W770010-000

19

GASKET

1

NP460045-000

20

SIDE COVER

1

NP250060-STL

21

BOLT

4

NP990414-188

22

GEAR

8:1

1

W208765-008

22

GEAR

10:1

1

W208765-010

22

GEAR

15:1

1

W208765-015

22

GEAR

30:1 (obsolete)

1

W208765-030

23

THRUST WASHER

1

NP470030-000

24

ECCENTRIC SHAFT

1

NP410055-000

25

BEARING

2

NP400040-000

26

STRK ADJ ASSEMBLY

1

NP260013-000

27

KNOB

1

NP260001-GPC

28

KNOB COVER

1

NP250061-000

29

SCREW

1

W771001-010

DISCHARGE

SUCTION
SUCTION

35

NP140055-BRS

4

NP991018-188

1

NP32BVC8-PVD

30

LABEL

1

NP550084-000

31

WASHER

1

W771006-STL

32

MOTOR ADAPT ASSY 56C

1

NP490030-000

32

MOTOR ADAPT ASSY 71

1

NP490029-000

33

WORM SHAFT ASSY 56C

1

NP060032-A00

33

WORM SHAFT ASSY IEC71

1

NP060032-B00

34

DC4/5 GEARBOX

1

NP010023-ALU

35

NAME TAG

1

NP550130-000

36

NAME TAG SCREW

4

W771000-188

38

SET SCREW

2

W771004-032

40

KEY-WORM GEAR

1

W773098-004

41

RETAINING RING

1

NP999032-STL

42

GASKET

1

NP460047-000

43

SCREW

2

NP990008-STA

44

OIL SEAL

1

NP450029-000

45

SPOOL ADAPTOR BOLT

4

W770534-STL

46

SPOOL ADAPTOR WASHER

4

NP991018-188

36

14.6 Bill of Materials, DC5
ITEM
1

DESCRIPTION
SUPPORT PLATE

QTY
1

PART NUMBER
NP140071-BRS

2

DIAPHRAGM

1

NP170037-THY

3

REAGENT HEAD PVDF

1

NP160022-PVD

3

REAGENT HEAD PP

1

NP160022-PPL

3

REAGENT HEAD PVC

1

NP160017-PVC

3

REAGENT HEAD 316

1

NP160004-316

4

BOLT

6

NP990436-188

5

FLT WASHER

6

NP991018-188

7

VLV ASSY DISCHARGE PVDF

NPT

1

NP87NLFUCJ-DISC

7

VLV ASSY DISCHARGE PVDF

ISO 7-1

1

NP87NLFUCJ-BDIS

7

VLV ASSY DISCHARGE 316

NPT

1

NP87AAAUCJ-DISC

7

VLV ASSY DISCHARGE 316

ISO 7-1

1

NP87AAAUCJ-BDIS

7

VLV ASSY DISCHARGE PVC

NPT (obs)

1

NP87SLVUCJ-DISC

7

VLV ASSY DISCHARGE PVC

ISO 7-1 (obs)

1

NP87SLVUCJ-BDIS

8

VLV ASSY SUCTION

PVDF

NPT

1

NP87NLFUCJ-SUCT

8

VLV ASSY SUCTION

PVDF

ISO 7-1

1

NP87NLFUCJ-BSUC

8

VLV ASSY SUCTION

316

NPT

1

NP87AAAUCJ-SUCT

8

VLV ASSY SUCTION

316

ISO 7-1

1

NP87AAAUCJ-BSUC

8

VLV ASSY SUCTION

PVC

NPT (obs)

1

NP87SLVUCJ-SUCT

8

VLV ASSY SUCTION

PVC

ISO 7-1 (obs)

1

NP87SLVUCJ-BSUC

9

RETURN SPRING

1

NP430034-000

10

BOTTOM COVER

1

NP250085-000

11

BOTTOM COVER BOLT

4

NP992216-STL

12

STRADLE ASSEMBLY

1

NP410067-000

13

BEARING

1

NP400038-000

14

ECCENTRIC

1

NP070023-000

15

BEARING

1

NP400042-000

16

DC5 SPOOL ADAPTOR

1

NP140069-ALU

17

WORM

8:1

1

W208764-008

17

WORM

10:1

1

W208764-010

17

WORM

15:1 (obsolete)

1

W208764-015

17

WORM

30:1 (obsolete)

1

W208764-030

18

SCREW

1

W770010-000

19

GASKET

1

NP460045-000

20

SIDE COVER

1

NP250060-STL

21

BOLT

4

NP990414-188

22

GEAR

8:1

1

W208765-008

22

GEAR

10:1

1

W208765-010

22

GEAR

15:1 (obsolete)

1

W208765-015

22

GEAR

30:1 (obsolete)

23

THRUST WASHER

24

ECCENTRIC SHAFT

1

NP410055-000

25

BEARING

2

NP400040-000

26

STRK ADJ ASSEMBLY

1

NP260013-000

27

KNOB

1

NP260001-GPC

28

KNOB COVER

1

NP250061-000

37

1

W208765-030

1

NP470030-000

29

SCREW

1

W771001-010

30

LABEL

1

NP550084-000

31

WASHER

1

W771006-STL

32

MOTOR ADAPT ASSY 56C

1

NP490030-000

32

MOTOR ADAPT ASSY 71

1

NP490029-000

33

WORM SHAFT ASSY 56C

1

NP060032-A00

33

WORM SHAFT ASSY IEC71

1

NP060032-B00

34

DC4/5 GEARBOX

1

NP010023-ALU

35

NAME TAG

1

NP550130-000

36

NAME TAG SCREW

4

W771000-188

38

SET SCREW

2

W771004-032

40

KEY-WORM GEAR

1

W773098-004

41

RETAINING RING

1

NP999032-STL

42

GASKET

1

NP460047-000

43

SCREW

2

NP990008-STA

44

OIL SEAL

1

NP450029-000

45

SPOOL ADAPTOR BOLT

4

W770534-STL

46

SPOOL ADAPTOR WASHER

4

NP991018-188

47

TIEBAR

2

NP360004-000

48

TIEBAR BOLT

8

NP990435-188

49

TIEBAR WASHER

8

NP991018-188

38

14.7 Bill of Materials, DC6
ITEM

DESCRIPTION

QTY
1

PART NUMBER

1

SUPPORT PLATE

NP140081-STL

2

DIAPHRAGM

1

NP170039-THY

3

REAGENT HEAD FPP

1

NP160023-FPP

3

REAGENT HEAD PVDF

1

NP160023-PVD

3

REAGENT HEAD 316

1

NP160031-316

4

BOLT

6

NP990477-188

5

FLT WASHER

6

NP991018-188

7

VLV ASSY DISCHARGE PVDF

NPT

1

NP87NLFUCJ-DISC

7

VLV ASSY DISCHARGE PVDF

ISO 7-1

1

NP87NLFUCJ-BDIS

7

VLV ASSY DISCHARGE 316

NPT

1

NP87AAAUCJ-DISC

7

VLV ASSY DISCHARGE 316

ISO 7-1

1

NP87AAAUCJ-BDIS

8

VLV ASSY SUCTION

PVDF

NPT

1

NP87NLFUCJ-SUCT

8

VLV ASSY SUCTION

PVDF

ISO 7-1

1

NP87NLFUCJ-BSUC

8

VLV ASSY SUCTION

316

NPT

1

NP87AAAUCJ-SUCT

8

VLV ASSY SUCTION

316

ISO 7-1

1

NP87AAAUCJ-BSUC

9

RETURN SPRING

1

NP430034-000

10

BOTTOM COVER

1

NP250085-000

11

BOTTOM COVER BOLT

4

NP992216-STL

12

STRADLE ASSEMBLY

1

NP410067-000

13

BEARING

1

NP400038-000

14

ECCENTRIC

1

NP070023-000

15

BEARING

1

NP400042-000

16

DC5 SPOOL ADAPTOR

1

NP140080-ALU

17

WORM

8:1

1

W208764-008

17

WORM

10:1

1

W208764-010

18

SCREW

1

W770010-000

19

GASKET

1

NP460045-000

20

SIDE COVER

1

NP250060-STL

21

BOLT

4

NP990414-188

22

GEAR

8:1

1

W208765-008

22

GEAR

10:1

1

W208765-010

23

THRUST WASHER

1

NP470030-000

24

ECCENTRIC SHAFT

1

NP410055-000

25

BEARING

2

NP400040-000

26

STRK ADJ ASSEMBLY

1

NP260013-000

27

KNOB

1

NP260001-GPC

28

KNOB COVER

1

NP250061-000

29

SCREW

1

W771001-010

30

LABEL

1

NP550084-000

31

WASHER

1

W771006-STL

32

MOTOR ADAPT ASSY 56C

1

NP490030-000

32

MOTOR ADAPT ASSY 71

1

NP490029-000

33

WORM SHAFT ASSY 56C

1

NP060032-A00

33

WORM SHAFT ASSY IEC71

1

NP060032-B00

39

34

DC4/5/6 GEARBOX

1

35

NAME TAG

1

NP550130-000

36

NAME TAG SCREW

4

W771000-188

38

SET SCREW

2

W771004-032

40

KEY-WORM GEAR

1

W773098-004

41

RETAINING RING

1

NP999032-STL

42

GASKET

1

NP460047-000

43

SCREW

2

NP990008-STA

44

OIL SEAL

1

NP450029-000

45

SPOOL ADAPTOR BOLT

4

W770534-STL

46

SPOOL ADAPTOR WASHER

4

NP991018-188

47

TIEBAR

2

NP360004-000

48

TIEBAR BOLT

8

NP990435-188

49

TIEBAR WASHER

8

NP991018-188

40

NP010023-ALU

41

STANDARD PUMP OPERATIONS
27101 Airport Road
Punta Gorda, FL
33982
(941) 575-3800
Fax (941) 575-4085
www.pulsatron.com

Bulletin #: IOM-OM-1104- E
Rev E

42



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2007:04:27 15:01:42Z
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2007:09:13 15:03:27-05:00
Metadata Date                   : 2007:09:13 15:03:27-05:00
Format                          : application/pdf
Creator                         : bjavits
Title                           : Microsoft Word - OMNI IOM Rv E.doc
Producer                        : GPL Ghostscript 8.15
Document ID                     : uuid:f6ad0e83-c0d5-4b1f-bbb6-d5af4eee3107
Instance ID                     : uuid:2aae06d0-27a3-458c-95ec-b3fbb40100b3
Page Count                      : 46
Author                          : bjavits
EXIF Metadata provided by EXIF.tools

Navigation menu