360° Ceiling Mount PIR+MW Dual-Tech Motion Detector DP-363 GENERAL Installation Instructions PCB Disassembly Diagram Thank you for choosing IR-TEC dual technology motion detector for your security system. The DP-363 is a 360° ceiling mount motion detector that combines a passive infrared (PIR) and a DRO microwave (MW) motion sensor in a sleek housing. It utilizes AND logic discretion and advanced signal processing to provide superior intrusion detection reliability. To achieve the best detection, please read all instructions thoroughly prior to installation. INSTALLATION HINTS Description 1. The DP-363 should be mounted on a firm section of ceiling and located for optimum coverage. 2. Do not install where the detector is exposed to direct or mirror-reflected sunlight. 3. Make sure the detection area does not have obstruction which may block the detection zones. 4. Avoid running the alarm cable along with AC mains cable to prevent EMI. 5. Locate the detector at least 0.3 m (1ft) away from fluorescent light to avoid possible interference to the microwave sensor. 1. Loosen the cover locking screw, open the cover. 2. Refer to the PCB disassembly diagram, carefully remove the PC board from the bottom base. 3. Knockout the adequate cable access and mounting holes on the bottom base. 4. Lead the alarm cable through the access hole, and mount the bottom base at the selected location. 5. Replace the PCB at the bottom case. Connect the signal wires with the terminals according to the wiring diagram as below. 6. Replace the front cover and then walk test can be conducted. INTERNAL VIEW/INSTALLATION Wiring Diagram Internal View Warning: TAMPER output should connect with the 24- hour N.C supervised loop of control panel. DETECTION PATTERN Installation Illustration WALK TEST & ADJUSTMENT FUNCTION SETTING SW1 DIP switch is available for all function settings of the detector. Please refer to the following instructions for setting options. The black blocks indicate switch position. The left shows factory default setting. Function Setting Indication Function Pulse Trigger LED Alarm Setting Count Count ON/OFF Output ON ON ON NC (Refer to next OFF OFF OFF NO table) SW# MW Sensitivity Microwave Sensitivity Setting MW Sensitivity 60% 80% Detection Coverage 4x4m (@3m high) 6x6m 100% 8x8m (default) Please refer to the following instructions to conduct walk test and MW adjustment. Walk Test 1. 2. Apply DC power supply and wait about 60 seconds for sensor to warm up. During warm up period, both red and green LEDs will light up. After the warm up time expires, walk across the detection area at normal speed. Check if the red and green LED turn on/off following by tester’s walk/stop. Sensitivity Adjustment If there is no movement within the detection range and the green LED remains on, this means that MW sensor is probably over sensitive (usually appears in a smaller room). Please reduce the MW sensitivity in accordance with the MW sensitivity setting table. 120% 12x12m Switch Setting 1. Pulse Count The DP-363 features intelligent pulse count in its PIR sensor which can effectively prevent false alarms cause by environmental interference. If it is installed at the places with rapid temperature change or unknown electrical interference, DIP switch #1 which controls the PIR pulse count can be set to ON position for 3 pulses to increase the detection reliability. Note: Regular walk test must be carried out, as part of routine maintenance at least once a year. The mounting height should be at least at 2.4m. SPECIFICATIONS MW frequency MW output power Power supply Current drain Infrared sensor Microwave sensor Mounting height Alarm period Alarm output 2. Trigger Count 10.525GHz 10dBm EIRP 9~16VDC (12 VDC nominal) 17mA@12VDC Omni-directional, dual element, low noise DRO w/m micro strip antenna 2.4~3.6m 2~4 sec. NC/NO, selectable, 30VDC, 0.2A max. 60sec.Red/ G reen LED on Red, can be disabled Green, can be disabled NC, cover open activates PIR 1/3, selectable -20° C~ 55° C (-4° F ~ 131°F ) 110 (dia.) x 44mm (H) When pulse count is already set on, and the detector still experiences false alarm caused by unknown factor, then “Trigger Count” can be enabled. With trigger count enabled, the detector will hold the alarm output for a short period of time and release the alarm signal only when a true intrusion is verified by sophisticated signal processing software. Warning: Once the trigger count is enabled, the alarm output will be slower than normal. Thus, walk test must be conducted to ensure that detector not to miss catching the intrusion. W arm up peri od Alarm output LED MW sensor LED Tamper protection Pulse count Op. temperature Di m ensi ons 3. LED Indication Operation is subject to the following two conditions: The LED of DP-363 indicates the operation status of the detector. When the green LED lights up, it means the MW sensor is active. When the red LED lights up, it shows the alarm output (also represents the infrared sensor is active). If it is necessary to disable the LED indication, just set DIP switch #3 to OFF position. 06/07’ FCC ID: NRIDP363 This device complies with Part 15 of the FCC Rules. (1) This device may not cause harmful interference, and (2) This device must accept any interference received, Including interference that may cause undesired operation. 058-36321-001 Note: 1.Any changes of modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. 2.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract, Print high-res XMP Toolkit : 3.1-701 Create Date : 2007:07:02 10:27:20+08:00 Creator Tool : pdfFactory Pro www.ahasoft.com.tw/FinePrint Modify Date : 2007:07:02 10:28:37+08:00 Metadata Date : 2007:07:02 10:28:37+08:00 Format : application/pdf Creator : Annie Title : DP-363英文說明書草稿.doc Producer : pdfFactory Pro 3.10 (Windows XP Professional Chinese) Document ID : uuid:506b2b5b-79dc-41a1-9ce7-1cacbc0c4f47 Instance ID : uuid:80204df3-a6a4-477f-9df0-c75b10c52655 Page Count : 3 Author : AnnieEXIF Metadata provided by EXIF.tools