Indyme Solutions SD The Smart Dome uses a passive infrared motion sensor to detect the presence of people and send messages based on detection algorithms User Manual

Indyme Solutions, Inc The Smart Dome uses a passive infrared motion sensor to detect the presence of people and send messages based on detection algorithms Users Manual 1

a href="https://usermanual.wiki/Indyme-Solutions" itemprop="url"> Indyme Solutions >

Contents

Users Manual 1

   Technical Document 430758-01 Rev. B Indyme Solutions, Inc.⬧ 8295 Aero Place ⬧ San Diego, CA 92123 USA                                                         +1.858.268.0717 ⬧ +1.800.829.6141  Page 1 of 6 DM9030SA/DM9031A SmartDome™ Dwell Detector  Programming and Installation Instructions Overview The DM9030SA/DM9031A SmartDome™ are part of Indyme’s Smart Sense Solution Suite. Indyme smart devices use custom algorithms and intelligent sensors to detect activity within the coverage area. The SmartDome™ uses a Passive Infrared sensor to detect when someone is dwelling in a coverage area beyond a defined threshold. Once detected, SmartDome™ can be programmed to activate both local and/or remote alerts through the Indyme infrastructure. As a member of the Indyme Global Solutions Family, the DM9030SA/DM9031A can also communicate with other GSF devices. GSF and Smart devices operate in the 800-900MHz frequency spectrum. They are not compatible with legacy devices.  SmartDome™ Programming Indyme Smart devices are programmed using our cloud based Smartportal Service and the local Indyme infrastructure. Ensure the Indyme control unit and access point(s) are installed and operational, with full access to Smartportal before proceeding. Incomplete infrastructure will prevent programming of any Smart devices.  The DM9030SA is preprogrammed to function directly out of the box.  No additional programming is necessary.  The DM9031A device leaves the factory at default settings, these settings will NOT function in a customer environment. All devices must be properly programmed using the Smartportal website. Smart devices use three primary programming parameters; Location, Activity Profile and Alert Profile. These parameters will be provided with your Work Order. Identify the locations and profiles before you begin programming.   • Location – department in the store where the device will be installed. • Activity Profile – setting used to indicate timing algorithms for activation. (default activity profile is “Cosmetic”) • Alert Profile – settings used to activate the local device alert tone and LED. (default alert profile is “On”)  Using your internet enabled device; cellphone, tablet or laptop, and the credentials provided on your Work Order, login to the website, https://smartportal.indyme.com .  Follow the on-screen instructions to configure each DM9031A, one at a time. It is NOT advisable to have multiple users logged into the same Work Order. Failure to follow these instructions will result in a failed installation of some or all devices.   NOTE: The DM9031A devices should be programmed while in the designated location OR after they are physically mounted.   Activation Button
   Technical Document 430758-01 Rev. B Indyme Solutions, Inc.⬧ 8295 Aero Place ⬧ San Diego, CA 92123 USA                                                         +1.858.268.0717 ⬧ +1.800.829.6141  Page 2 of 6 1. On the Installer Registration screen, enter your name and contact information. This information will be used by Indyme Support personnel throughout the install and to ensure you are at the correct job site. 2. On the Work Order screen, verify the listed details match your present job site and, the list of devices match your inventory of products. Once all details are confirmed, select the “Start Work” button and begin your installation. 3. With the Devices screen showing, insert two size “C” Alkaline batteries into the DM9031A (should be included in the DM9031A box). The device will power up and produce a VERY LOUD “chime” tone and the LEDs will flash. The unit will associate with the local Indyme infrastructure, (access point and control unit), and its unique-id will appear highlighted in green on the webpage. Verify the unique-id that appears matches the sticker inside the DM9031A. 4. Select the highlighted device, (DM9031A).  In the Device Details screen, select the Location where the device will be installed.  The Activity Profile and Alert Profile will automatically be filled in.  Do not change these values. 5. Select the “Add Picture” button and take a picture of the device properly mounted.  6. Select the “Save” button. 6a.  (After the Save button), A “Sending Changes” pop up will appear. This will transfer the Device’s data to             the control unit. 6b.  The “Ready for Activation” pop up appears directing the user to press the button to activate changes. 6c.  Push the activation button as indicated.  When the transaction is complete, another pop up will appear – “Your changes have been saved.  Return to devices list?”.   Select Yes 6d.  Repeat until all DM9031A devices are properly programmed.  7. Once all devices have been programmed, return to the Work Order screen. Verify the number of Completed devices. Select the “Stop Work” button and close the work order. 8. Call Indyme to verify the devices are correctly configured and working.  NOTE: The DM9031A devices should be programmed while in the designated location OR after they are physically mounted.  SmartDome™ Installation The DM9030SA/DM9031A SmartDome™ are designed as ceiling mounted devices. They may be mounted directly to a drop-tile ceiling grid, extended from the grid using a telescoping pole or extended from a ceiling truss. Mounting hardware is available for all options. For ceiling heights of 11-feet or less, the should be direct mounted, heights of 12-feet or greater should use the telescoping pole.  Required Tools The following tools are recommended to complete the installation according to these instructions; (1) 1/4” or 1/2” socket wrench handle, (1) 9/16” socket, (1) 7/16” deep socket, (1) 3/16” Allen wrench, (1) pair pliers, (1) Philips screwdriver.
Download:
Mirror Download [FCC.gov]
Document ID3903599
Application IDor87E7y0ImQzgiWVLeO1xw==
Document DescriptionUsers Manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize47.72kB (596499 bits)
Date Submitted2018-06-27 00:00:00
Date Available2018-06-29 00:00:00
Creation Date2018-06-20 15:03:05
Producing SoftwareMicrosoft® Word 2016
Document Lastmod2018-06-20 15:03:05
Document TitleUsers Manual 1
Document CreatorMicrosoft® Word 2016
FCC ID Filing: J69SD

Navigation menu