Itron NIC511-LTE MicroAP 5 User Manual MicroAP 5 Meter Labeling Product Requirements
Silver Spring Networks MicroAP 5 MicroAP 5 Meter Labeling Product Requirements
Itron >
Contents
- 1. Users manual
- 2. Users Manual
Users manual
MICROAP 5 METER LABELING PRODUCT REQUIREMENTS Silver Spring Networks 230 West Tasman Drive San Jose, CA 95134 www.silverspringnet.com MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 1 MicroAP 5 Meter Labeling Product Requirements Confidential Information of Silver Spring Networks®, Inc., provided under nondisclosure obligations. Copyright © 2017 Silver Spring Networks, Inc. All rights reserved. The following are registered trademarks of Silver Spring Networks, Inc: the Silver Spring Networks name and logo, Altogether Brilliant®, Connect to the Energy Network®, CustomerIQ®, GreenBox®, GridScape®, Micromesh®, Power Over Energy®, Silver Spring®, Silver Spring Networks (and design)®, UtilityIQ®, UtilOS®. The following are trademarks of Silver Spring Networks, Inc: Connect to The Everything Network™, EnergyIQ™, Gen™, GreenIQ™, MicroAP™, Milli™, NetworkIQ™, OpsIQ™, Rings Logo™, SensorIQ™, SilverLink™, Streetlight.Vision™, The Internet of Important Things™. All other company and product names are used for identification purposes only and may be registered trademarks, trademarks, or service marks of their respective owners. Contact us. Email techpubs@silverspringnet.com with suggestions or corrections for this or any document. Customer Support Telephone Hours Email Toll free within the US and Canada: 1-888-SSN-9876 (1-888-776-9876) 5:00 AM - 6:00 PM US Pacific Time support@silverspringnet.com 9:00 AM - 9:00 PM Australia Eastern Time aus-support@silverspringnet.com Non-toll-free: 1-669-770-4298 In Australia: 1300 706 769 Contact us on the Web: http://www.silverspringnet.com/services/customer-support/ MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 2 MicroAP 5 Meter Labeling Product Requirements Contents Contents 1. About MicroAP 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Meter Labeling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Meter Nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Meter Auxiliary Label or NIC Address Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 NIC Labeling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. FCC and Government Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 FCC Guidelines for Devices Containing a Transmitter Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Industry Canada Guidelines for Devices Containing a Transmitter Module . . . . . . . . . . . . . . . . . . . . . 9 MicroAP 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 General Electrical Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 1 MicroAP 5 Meter Labeling Product Requirements 1 About MicroAP 5 About MicroAP 5 MicroAP 5 is a WAN-enabled Network Interface Card (NIC) enabling Micromesh™ technology. MicroAP 5 complies with FCC Part 15.247 and RSS-GEN of Industry Canada rules. It enables machine-to-machine communication over 900 MHz and 2.4 GHz and transmits data over LTE Cat.1 cellular backhaul to the utility or network provider. MicroAP also incorporates an 802.15.4-compliant ZigBee® radio for Home Area Networking (HAN). Figure 1. MicroAP 5 References Guidelines for 64-bit Global Identifier (EUI-64™) Registration Authority, IEEE Standards Association. MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 2 MicroAP 5 Meter Labeling Product Requirements 1 About MicroAP 5 Specifications The hardware specifications for MicroAP 5 are listed in Table 1. Table 1. MicroAP 5 specifications Feature Description 900-MHz NAN Transceiver: Frequency range 902-928 MHz North America Data rate Up to 2.4 Mbps Spread Spectrum technology Frequency Hopping Transmitter output Up to 1W Receiver sensitivity -98 dBm for 10% PER @ 100 kbps 2.4-GHz Communications: Frequency range 2.4 GHz, ISM Band Data rate Up to 2.4 Mbps Spreading technique FHSS Transmitter output Up to 500mW Receiver sensitivity -94 dBm @ 10% PER 2.4-GHz HAN Transceiver: Frequency range 2.4 GHz, ISM Band Data rate 250 kbps Spreading technique Direct Sequence MAC/Channels 802.15.4/ 16 Transmitter output Up to 200mW Receiver sensitivity -94 dBm @ 10% PER NAN Network: Addressing 8 byte MAC Address Protocol UDP/IPv6 Confidentiality AES-256 Encryption Authentication ECDSA & RSA Signatures HAN Network: Protocols ZigBee Pro Device Types Network Coordinator/End Device Profile SmartEnergy Profile 1.1 WAN Transceiver (NA1): Frequency Ranges 4G Bands: B12/B17 (700), B5(850), B4(aws1700), B2 (1900) 3G Bands: B2 (1900), B5 (850) Transmitter Output Up to 250 mW (per specification) WAN Transceiver (SV1 Version): MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 3 MicroAP 5 Meter Labeling Product Requirements 1 About MicroAP 5 Table 1. MicroAP 5 specifications (Continued) Feature Description Frequency Ranges 4G LTE Bands: B2 (1900), B4 (AWS1700), B13 (700) Transmitter Output Transmitter Output: Up to 200 mW Environmental Operating Temperature (the ambient temperature at the NIC -40°C to +85°C Humidity 95%, non-condensing Interfaces: Meter ANSI LVTTL Levels DLMS/COSEM Physical: Size 110 x 62 x 22.8 (mm) Weight 39 grams Meter Labeling Meter Nameplate The meter nameplate shall not contain information pertaining to the Silver Spring Networks radio. Figure 2. Example of meter nameplate label Meter Auxiliary Label or NIC Address Label For radio identification, the meter shall have an auxiliary label containing the Silver Spring Networks NIC address presented in text (16 alphanumeric digits) and bar code formats. • Bar Code Type = Code 3 of 9 • Bar Code Font Size = unknown • Font Type = unknown • Font Size = unknown • Bar Code Label Dimensions = 1.50ʺ x 0.25ʺ • Bar Code Material Type = Static Dissipative Polyimide MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 4 MicroAP 5 Meter Labeling Product Requirements 1 About MicroAP 5 Figure 3 shows an example of the NIC address label, which is consistent with FCC requirements set forth in section 4.1, and contains the Silver Spring Networks corporate name and NIC EUI-64 address. Figure 3. Example of NIC address label for NIC 511-NA1-0313 Silver Spring Networks 1234567890123456 Contains: FCC ID: OWS-NIC511-LTE, FCC ID:R17LE910NAV2 IC: 5975A-NIC511LTE, IC: 5131A-LE910NAV2 The NIC address label shall be placed on the meter nameplate in the location identified by “Label A” in the following figure. Figure 4. Nameplate NIC address locations NIC Labeling The Silver Spring Networks MicroAP 5 has two labels relevant to meter final assembly and RMA: the Regulatory/Catalog Number and the Silver Spring NIC address label. The Regulatory/Catalog # label is located on the top side of the NIC PCA, the NIC address label is located on the bottom. MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 5 MicroAP 5 Meter Labeling Product Requirements 1 About MicroAP 5 The Regulatory label is 1ʺ x .375ʺ inches (2.5 x 1 cm). Figure 5 shows an example of the FCC ID label found on the NIC 511-NA1-0313. Figure 6 shows an example of the Silver Spring NIC address label. Figure 5. Sample FCC ID label for MicroAP NIC 511-NA1-0313 Catalog: 343-012345 NIC 511-NA1-0313 FCC ID: OWS-NIC511-LTE IC: 5975A-NIC511LTE Figure 6. Silver Spring NIC 511-NA1-0313 address label example XXX-XXXX-XX Rev XX MAC: XXXXXXXXXXXXXXXX Figure 7 shows the placement of the labels. The QR code label contains the same information as the Silver Spring NIC address label. Figure 7. Label locations on MicroAP 5 MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 6 MicroAP 5 Meter Labeling Product Requirements 2 FCC and Government Guidelines FCC and Government Guidelines Table 2. MicroAP 5 NIC Models NIC Model 902 MHz 2.4 GHz NAN Int. Ant Option 511-NA1-0313 Yes Yes Yes NAN Ext. Ant Option Cell Ext. Ant Option Yes Yes FCC ID IC OWS-NIC511LTE 5975A-NIC511LTE 5131A-LE910NAV2 RI7LE910NA V2 511-NA1-0312 Yes Yes No Yes Yes OWS-NIC511LTE 5975A-NIC511LTE 5131A-LE910NAV2 RI7LE910NA V2 511-SV1-0313 Yes Yes Yes Yes Yes OWS-NIC511LTE 5975A-NIC511LTE 5131A-LE910SVV2 RI7LE910SV V2 511-SV1-0312 Yes Yes No Yes Yes OWS-NIC511LTE 5975A-NIC511LTE 5131A-LE910SVV2 RI7LE910SV V2 Requirements The MicroAP 5 is REQUIRED to be professionally installed by a properly trained technician. Improper installation could void the userʹs authority to operate the equipment. This device complies with Part 15 of the FCC Rules and RSS-Gen of Industry Canada Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. The antenna of this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The device should be installed so that people will not come within 20 cm (8 in.) of the antenna. MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 7 MicroAP 5 Meter Labeling Product Requirements 2 FCC and Government Guidelines This equipment has been tested and found to comply with Part 15 of the FCC Rules and RSS-GEN of Industry Canada rules. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception (which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver disconnected. • Consult the dealer or an experienced radio/TV technician for help. FCC Guidelines for Devices Containing a Transmitter Module The following is an extract from FCC PART 15 UNLICENSED MODULAR TRANSMITTER APPROVAL, DA 00-1407, Released: June 26, 2000, Section 6 describing labeling requirements for devices containing a modular transmitter. Section 6. The modular transmitter must be labeled with its own FCC ID number, and, if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: XYZMODEL1” or “Contains FCC ID: XYZMODEL1.” Any similar wording that expresses the same meaning may be used. The Grantee may either provide such a label, an example of which must be included in the application for equipment authorization, or, must provide adequate instructions along with the module which explain this requirement. In the latter case, a copy of these instructions must be included in the application for equipment authorization. Figure 8. Sample FCC ID label for devices containing a MicroAP 5 (Model NIC 511-NA1-0313) Contains: FCC ID: OWS-NIC511-LTE, R17LE910NAV2 IC: 5975A-NIC511LTE, 5131A-LE910NAV2 MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 8 MicroAP 5 Meter Labeling Product Requirements 2 FCC and Government Guidelines Figure 9. Sample FCC ID label for devices containing a MicroAP 5 (Model NIC 511-SV1-0313) Contains: FCC ID: OWS-NIC511-LTE R17LE910SVV2 IC: 5975A-NIC511LTE, 5131A-LE910SVV2 Industry Canada Guidelines for Devices Containing a Transmitter Module MicroAP 5 External Antenna Integration This radio transmitter 5975A-NIC511LTE has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. • Omnidirectional antennas: 6 dBi at 900 MHz, 4.5 dBi at 2.4 GHz • Cellular antennas: 6.63 dBi for 700 and 850 MHz; 6.0 dBi for 1700 MHz; 8.51 dBi for 1900 MHz Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle sʹil fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types dʹantenne énumérés ci-dessous et ayant un gain admissible maximal et lʹimpédance requise pour chaque type dʹantenne. Les types dʹantenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour lʹexploitation de lʹémetteur. • Antennes omnidirectionnelles: 6 dBi à 900 MHz, 4.5 dBi à 2,4 GHz • Antennes cellulaire: 6.63 dBi a 700 & 850 MHz; 6.0 dBi a 1700 MHz; 8.51 dBi a 1900 MHz Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation dʹIndustrie Canada, le présent émetteur radio peut fonctionner avec une antenne dʹun type et dʹun gain maximal (ou inférieur) approuvé pour lʹémetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à lʹintention des autres utilisateurs, il faut choisir le type dʹantenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas lʹintensité nécessaire à lʹétablissement dʹune communication satisfaisante. MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 9 MicroAP 5 Meter Labeling Product Requirements 2 FCC and Government Guidelines For Transmitters Not Requiring Licenses This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR dʹIndustrie Canada applicables aux appareils radio exempts de licence. Lʹexploitation est autorisée aux deux conditions suivantes : (1) lʹappareil ne doit pas produire de brouillage, et (2) lʹutilisateur de lʹappareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible dʹen compromettre le fonctionnement. Safety Information XX WARNING: Severe shock and explosion hazard! Touching energized parts can result in massive equipment damage, and severe injury or death. Short-circuiting energized parts will result in blinding flash and explosion. Opening and closing electrical circuits can also produce dangerous and explosive arc flashes. Involuntary muscular reactions associated with electrical shock may result in other injuries. Observe the following safety guidelines. Careful planning of every job is essential. Nothing should be taken for granted. Do not take chances! • Read and follow all approved policies and procedures provided by your employer associated with the procedures in this manual. • The procedures in this manual must only be performed by qualified workers in accordance with local utility safety practices, utility requirements, and applicable OSHA and NFPA standards. • The information contained in this document is intended to aid qualified personnel, and is not a replacement for the proper training required to make a person qualified. • Silver Spring Networks assumes no liability for the customerʹs failure to follow these safety guidelines. General Electrical Safety • Perform the procedures in this manual in accordance with applicable workplace standards established by the following agencies: — Occupational Safety and Health Act (OSHA). — The National Electrical Code published by the National Fire Protection Association (NFPA-70). — National Electrical Manufacturers Association (NEMA). — Electronics Industries Association (EIA). — Insulated Power Cable Engineers Association (IPCEA). • American National Standards Institute (ANSI). Whenever possible, de-energize all circuits or equipment before working on them. MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 10 MicroAP 5 Meter Labeling Product Requirements 2 FCC and Government Guidelines • Maintain a minimum clearance of 10 feet (3 meters) between line potential and all unqualified persons at all times. • Keep unauthorized people out of the work area. Be especially cautious of children, who tend to be drawn to work activity. • Determining if a circuit is OFF can be difficult in some instances. Check for circuit voltage with an appropriate voltmeter before working on equipment presumed to have been deenergized. Tiebreakers, double throw disconnect switches, automatic transfer switches and emergency generators can supply power through an alternate circuit or from another source. • 120V current can be just a lethal as higher voltages because current flow through a body depends upon the bodyʹs resistance. • Do not trust insulation and/or weatherproofing on a wire as protection from shock. • Use electrically insulated tools. Inspect portable electrical equipment or tools for defects and remove any defective devices from service immediately. All portable electrical equipment must have Ground Fault Circuit Interrupter (GFCI) protection. • Select the right tool for the job. Use tools properly. Keep tools in good working order. • Make sure the work area is free of any flammable material. Flammable vapors can be ignited by an arc flash. • Keep the work area clean and dry. Cluttered work areas cause accidents and injuries. • Provide good lighting in the work area. You cannot work safely if you cannot see what you are doing. • Report unsafe conditions or defective equipment to your immediate supervisor. • Handle material carefully. Lift and carry properly. MicroAP 5 Meter Labeling Product Requirements 1 March 2017 Silver Spring Networks 11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Silver Spring Networks Create Date : 2017:03:01 14:59:12Z Modify Date : 2017:03:01 15:15:14-08:00 Language : en Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : FrameMaker 2015.1 Metadata Date : 2017:03:01 15:15:14-08:00 Producer : Acrobat Distiller 15.0 (Windows) Format : application/pdf Title : MicroAP 5 Meter Labeling Product Requirements Creator : Silver Spring Networks Document ID : uuid:525d2fd6-e5f1-4852-b65b-dabad9a9e143 Instance ID : uuid:db2b0fda-d805-944c-acd4-3a523b2bfbd6 Page Mode : UseOutlines Page Count : 13EXIF Metadata provided by EXIF.tools