John Mills Speedfit Bs7291 Users Manual 4 SP/P/G 08.05

KM39767 to the manual 853c4ba8-0e72-4266-9c4a-3596e6cf86a5

2015-02-09

: John-Mills John-Mills-Speedfit-Bs7291-Users-Manual-566905 john-mills-speedfit-bs7291-users-manual-566905 john-mills pdf

Open the PDF directly: View PDF PDF.
Page Count: 16

The company has a policy of continuous research
and development and reserves the right to amend
without notice the specification and design of all
products illustrated in this catalogue. John Guest
Speedfit reserve the right to change the colour and
shape of products. Photographs are for illustration
purposes only.
Subject to our Terms and Conditions
of Sale available on request.
Z2105/217/10/07
No.’s 95/3177 BS7291
KM39767
AVAILABLE FROM:
THE PUSH-FIT SOLUTION FOR
PLUMBING & HEATING SYSTEMS
UK PRODUCT RANGE AND
INSTALLATION GUIDE
October 2007
, and are
registered
trademarks of John Guest International
Limited
© Copyright 2007.
CI/SfB
53.0 Ih6
John Guest Speedfit Limited
Horton Road, West Drayton, Middlesex UB7 8JL, England.
Tel: 01895 449233 Fax: 01895 420321. www.speedfit.co.uk
Technical Help Desk: 01895 425333
THE PUSH-FIT SOLUTION FOR
PLUMBING AND HEATING SYSTEMS
JG Speedfit is a push-fit system suitable for the plumbing
of normal domestic hot and cold water services and
central heating applications, including pressurised and
combi systems.
Speedfit Fittings have been designed for use with both
Speedfit and copper pipe.
Extensive tests have shown that Speedfit products will
withstand temperatures and pressures well in excess of
normal working conditions.
JG Speedfit should be installed to conform with good
plumbing practice.
British Gas Service has accepted the John Guest Speedfit
System as being suitable for open vented and sealed
central heating systems and as eligible for acceptance
onto its service contracts.
Performance specifications are well within those required
for most normal domestic central heating and water
supply systems including:
Mains fed and indirect cold water systems
Vented and unvented hot water systems
Vented central heating systems
Sealed central heating systems provided
temperatures and pressures comply with
BS7291 Parts 1, 2 and 3 Class S.
Underfloor heating
Speedfit PEX Fittings
and Barrier Pipe.
K24076, K24077 and K24078
British Gas
Service
BS7291
No. KM39767
Worldwide connections
The John Guest Group has a long
established reputation as a world leading
manufacturer of push-in fittings, tube and
other fluid control products. A
reputation built on producing consistently
high quality products with an ongoing
commitment to value engineering and
product development.
01 02
Technical Support
Our national team of Technical Support Engineers is
available to help you get the best from your
S
S
p
p
e
e
e
e
d
d
f
f
i
i
t
t
System. This includes a free underfloor heating estimate
and CAD design service.
T
Te
ec
ch
hn
ni
ic
ca
al
l
H
He
el
lp
p
D
De
es
sk
k:
:
0
01
18
89
95
5-
-4
42
25
53
33
33
3
The J
JG
G
S
S
p
p
e
e
e
e
d
d
f
f
i
i
t
t
Technical Advisory Service is available
to assist and advise on the aspects of the
S
S
p
p
e
e
e
e
d
d
f
f
i
i
t
t
System. The service is available 8:00am to 5:00pm
Monday to Friday.
The System is approved by the BRA and the WRAS.
Speedfit ‘PEM’ fittings and PEX and Polybutylene Barrier
Pipe are Kitemarked to BS7291 Parts 1, 2 and 3 Class S
Licence No KM39767.
Quality Manufacture
A commitment to quality is at the heart of the John Guest Philosophy.
The strictest control is maintained by virtue of the fact that design and manufacture is carried
out in modern purpose built manufacturing centres in west London and at Maidenhead in
Berkshire.
Maintaining control over the whole process from initial tool design and tool making through
to final assembly and testing ensuring that only products of the highest quality are produced.
The company believe it is this commitment to quality that has led to it receiving prestigious
awards from many of the world’s leading testing and approvals organisations.
John Guest is a preferred supplier to many international companies.
Installation time reduced by up to 40%
Pipe flexibility permits the cabling of pipe through less
accessible areas
No risk of fire or flames from a blowtorch
Easier to work in confined places
A permanent leak-proof connection
Corrosion free
No scale build up
Lower thermal diffusivity maintains safer surface
temperature
Pipe elasticity can reduce the possibility of bursting
under freezing conditions
Lead free and non toxic
Less noise from water flow and expansion/contraction
Long pipe lengths reduce fittings required
SYSTEM FEATURES
All white system
Truly demountable without damage to pipe or fitting
Grip and seal connection
Superseal Insert gives secondary seal
Reduced pipe insertion force
Lightweight and easy to handle on site
SYSTEM BENEFITS
As a result of long term test programmes and rigorous
quality standards, John Guest Speedfit Limited offer a 25
year guarantee against the defects in materials or
manufacturing of ‘PEM’, ‘PSE’ and ‘SFM’ Range
Plumbing Fittings and Speedfit Barrier Pipe
manufactured by John Guest.
John Guest Underfloor Heating Products, which should
be installed and maintained in accordance with our
recommendations, carry a 2 year guarantee against
defects in materials and manufacture.
John Guest Plumbing and Heating Products are for use
with normal UK domestic plumbing and heating systems
and supplied in accordance with our Conditions of Sale.
GUARANTEE
Boats. The flexibility of the Speedfit System ensures it can
be cabled easily around the interior and hidden from view.
Caravans. Speedfit is ideal for caravan installations due
to its flexibility and its resistance to corrosion and freezing.
Exhibitions. The unique ability of the Speedfit System to
be easily demounted and reused, together with its
flexibility, makes Speedfit ideal for this application.
Agricultural and Horticultural.
Speedfit has many
applications in agricultural and horticultural environments.
Portable Buildings (site cabins, toilets). As with caravans,
Speedfit is well suited to this application.
Speedfit fittings suitable for central heating systems can
withstand temperatures up to 114°C intermittently for
short periods.
Speedfit fittings shown as not suitable for central heating
systems are used primarily on the domestic hot and cold
water system accepting temperatures of up to 65°C.
Ensure fittings and pipe are kept clean at all times by
keeping them in bags and boxes provided.
Do not empty Speedfit Products onto the floor area.
Ensure internal ‘O’ Ring seals are kept free from dirt and debris.
John Guest fittings and related products are specifically
designed and manufactured by John Guest to the
Technical Specifications set out in the John Guest
Product Catalogues. All John Guest fittings and related
products should be selected, installed, used and
maintained in accordance with these Technical
Specifications. It is the customer’s / user’s responsibility
to ensure that John Guest fittings and related products
are suitable for their intended applications, are properly
installed and maintained and are used in accordance with
the Technical Specifications. It is also the customer’s /
user’s responsibility to provide it’s own customers with
any relevant technical information about John Guest
products it supplies them.
Speedfit should not be used for gas, fuel oil or compressed
air applications.
John Guest produce a push fit system of pipe and fittings
for
compressed air situations. See seperate literature for details.
SPECIAL APPLICATIONS
WORKING TEMPERATURES AND PRESSURES
HANDLING FITTINGS AND PIPE
PRODUCT SELECTION AND INSTALLATION
03 04
Contents
PLUMBING AND HEATING
UNDERFLOOR HEATING
UNDERGROUND FITTINGS
TECHNICAL CHECKLISTS
Plumbing and 09 - 10
Heating Fittings
Flexi Hoses 11 - 12
Brass Fittings 12
Valves 13
Pipe and 14 - 15
Accessories
22 - 26
27 - 28
Designed to be quick and easy to install.
For connecting MDPE
Cold Water Service Pipe.
Plumbing and Heating 29
Underfloor Heating 30
Underground Fittings 30
Application Usual Working Maximum working Maximum working
temperature, ºC temperature, ºC pressure, bar
Cold Water 20 20 12
(indirect and direct mains)
Central Heating 82 105, short term 3
malfunction at 114
Hot Water 65 95 6
(including unvented cylinders)
HOW SPEEDFIT WORKS
Grips before it seals
Main ʻOʼ Ring Seal
Stainless steel teeth
grip the pipe
Pipe insert gives
secondary seal
Speedfit Fittings have a unique grip then seal construction made up of a collet with stainless
steel teeth to grip the pipe and an ‘O’ ring to provide a permanent leak proof seal.
Use of the Superseal Pipe Insert ensures a double ‘O’ ring seal.
An ‘O’ ring at the head of the insert and the shape of the stem, provide a secondary seal against
the bore of the fitting. A combination of this and the main ‘O’ ring ensure a good connection.
The stem of the insert gives greater rigidity of the length of pipe within the fitting, reducing the
chance of leaks if a side load is applied.
The head of the insert has been designed for ease of insertion.
The additional benefit of Twist and Lock Fittings is that a twist of a screwcap locks the pipe in
position and gives increased compression on the ‘O’ ring for even greater security.
MAKING A GOOD CONNECTION
Pipe Cutter
JG TS
Speedfit
Barrier Pipe
Ensure the pipe is free of score
marks. Cut the pipe square.
When using Speedfit Barrier Pipe
cut along an insertion mark. We
recommend the use of JG Pipe
Cutters.
To prevent damage to the ‘O’ ring
remove all burrs and sharp edges.
When connecting Speedfit Pipe
use a Superseal Pipe Insert. A
twisting motion will aid insertion.
The insert should only be used
with Speedfit Pipe.
Fittings and pipe should be kept clean bagged and undamaged
before use.
NEW TWIST AND LOCK FITTINGS
The fitting should be in the ‘unlocked’ position, this is
shown with a small gap between the screwcap and the
body flange.
Push the pipe fully into the fitting, up to the pipe stop. If
the Speedfit Pipe has been cut correctly the insertion
mark on the pipe will be level with the collet head. The ‘O’
ring on the Superseal Pipe Insert provides a secondary
seal against the bore of the fitting. A good connection
has been made.
Gap between Cap
and Flange
Pipe mark indicates
full insertion
Twist the screwcap until it
touches the body flange.
This increases the ‘O’ ring
seal around the pipe and
locks the pipe into position.
If you are not using collet
clips, ensure that the
screwcaps are in the
locked position.
Pull to check it is secure. It is good practice to test the system
prior to leaving the site or before use. Our recommended
test procedure is shown in our Technical Checklist.
ADDED BENEFIT TWIST AND LOCK
STANDARD SPEEDFIT FITTINGS
Standard Speedfit connections are made in the same way
as Twist and Lock.
Push Pipe up to Pipe Stop. If the Speedfit Pipe has been
cut correctly the insertion mark on the pipe will be level
with the collet head.
Push pipe up to stop
Secondary Seal
Pipe mark indicates
full insertion.
Pull to check connection
is secure and test the
system. Our recommended
test procedure is shown
in our Technical Checklist
on page 29.
TO DISCONNECT
Ensure that the system
is depressurised.
The screwcap on Twist
and Lock Fittings will
need to be turned back
to the unlocked position.
WHAT NOT TO DO
Fitting may be gripped but not
sealed if pipe is not fully inserted.
Don’t use hacksaws to cut the
pipe or leave burrs on the end of
the pipe.
Do not insert fingers into the fitting as the stainless steel
teeth may cause injury.
Remember to pressure test the completed installation
according to the recommendations in our Technical Checklist.
Don’t use
damaged or
scored pipe.
PREPARE THE PIPE
05 06
Push the collet square against the face of the fitting by
using fingers or with the help of our collet release tool.
With the collet held in position the pipe can be removed.
The fitting can be used again without the need for
replacement parts.
Don’t forget to push the
pipe fully into the fitting,
past both the collet (gripper)
and the ‘O’ ring.
Use a collet cover or collet clip to provide added security
against pipe disconnection, e.g. the fitting coming into
contact with rigid surfaces and behind dry-lining walls.
Collet covers for use with standard Speedfit fittings, are
available in white or in red or blue to allow colour coding of pipes.
Stops are located at the following distances from the end
of the fitting:
size 10mm 15mm 22mm 28mm
stop distance 20mm 30mm 35mm 44mm
Collet cover
Collet clips are available in grey and white for use with
standard fittings to prevent accidental pipe
disconnection.
Red or blue collet clips provide colour coding of pipe on
twist and lock fittings.
They are not designed to prevent accidental release and
should be fitted when the fitting is in the locked position.
Collet clip
The action of pressure in a system could increase the grip
of the collet. The release aid allows a firmer grip on the
collet whilst removing the pipe.
Release aid
PIPE STOP DISTANCES
COLLET COVERS
RELEASE AID
COLLET CLIPS
The unique feature of the
Speedfit Concept, the ability
to disconnect the fitting
should you want to, means
the Speedfit Stop End not
only provides a permanent
leakproof seal, but can be
readily removed to allow
work to restart or to allow
an extension to a system.
Thus, the fitting is especially
useful to allow water to be
turned back on, overnight for
instance, or if a job has to be
interrupted for another reason.
Stop end
Stop ends are also useful when pressure testing a system
before appliances are connected.
Designed to simplify pipe connection
in restricted spaces. The Speedfit
Stem Elbow provides an instant swivel
fitting so pipe can be orientated in
any direction.
A special 10mm version gives a neat
connection from concealed plumbing
to
a radiator.
STOP END
STEM ELBOW
The Speedfit range of brass
chromium plated service
valves can be used on both
hot and cold water services
and central heating. Push fit
connections mean much
reduced installation time,
especially in confined spaces.
The valves, in 10 to 22mm,
have a 1/4 turn open/close
mechanism operated by a
screwdriver slot or a lever.
Tap connector patterns have
a union nut to connect
direct to a tap or floatvalve.
Lever
operated valves are
supplied
with both a blue
and a red indice.
The ability of Speedfit products
to twist whilst in situ
allows
the screwdriver slot
operating valve to be turned
out of sight,
helping to avoid
unauthorised tampering.
Speedfit x Speedfit
Mechanism twists out of sight
SERVICE VALVE
Speedfit manufacturer a wide range of connectors
including conventional straight and bent tap connectors.
The range also offers a special and
unique Tap Connector that only
requires a simple hand tightening to
connect up a terminal tap, mixer or
float valve. An integral seal within the
fitting avoids the need for further
sealant. The connectors are useful
when replacing existing brassware or
in other confined spaces.
Coupling up to a supply is easy. The
pipe is simply pushed home into
the Speedfit connection and is
instantly secured, without the need
for specialist tools.
TAP CONNECTORS
Speedfit have introduced an innovative 22mm x 10mm 4
way manifold. Departing from the usual manifold design,
this new product has 4 in-line 10mm outlets, offering a
neater envelope size and therefore a much smaller
installation space.
Other benefits include better flow characteristics and a
more even distribution of hot water.
The 22mm and 10mm Speedfit push-fit connections make
for a fast and easy installation, even in confined spaces.
Whilst designed as a heating product, the manifold can
also be used in a mains pressure hot or cold domestic
plumbing system, to feed bathroom or kitchen taps and
mixers. This allows for a more efficient installation as
every terminal fitting has its own dedicated supply.
SPEEDFIT MANIFOLD
The Speedfit range includes an Appliance Tap for
the permanent connection of washing machines and
dishwashers, thus enabling complete water isolation to
the appliance.
A simple push fit connection of the supply pipe and a
plastic thread on the outlet to marry well with the plastic
thread on the hose means the Speedfit Appliance Tap is very
easy to install. The large round handle is easy to grip and turn.
APPLIANCE TAP
The Speedfit Connection, when made with the insert, has
a number of design features.
Sliding the stem of the insert into the pipe gives greater
compression of the main ‘O’ ring on the pipe and greater
rigidity of the length of pipe within the fitting, reducing the
chance of leaks if a side load is applied.
A connection is easier to make because the head of the
insert has been designed for ease of insertion.
Superseal Inserts are listed on page 14.
SUPERSEAL PIPE INSERT
07 08
Manufactured to a quality you would expect from Speedfit,
our range of Flexi Hoses has 40 different patterns.
Available in lengths from 150mm to 1,000mm, ends are
either push fit to union nut or push fit to push fit,
including
hoses with an integral
service valve operated by a 1/4 turn
screwdriver slot.
Apart from being aesthetically
pleasing the new white
hoses offer more flexibility and a larger through bore
for better flow characteristics.
More specialist patterns
have been designed to help
the installation of monobloc
mixers to a 15mm supply.
Sold in pairs, each hose in
the pair has a different
spanner location to ease
connection of the threaded
end into the monobloc’s
inlets.
The hoses are suitable for cold water up to 10 Bar and
hot water (65˚C max) up to 6 Bar and approved by WRAS.
The Superseal Pipe Insert has been developed to be used
with Speedfit Barrier Pipe and Speedfit Fittings to provide
an extra line of defence when installing a Speedfit Push
Fit System.
The insert has it’s own ‘O’ ring which, with a stem sliding
within the inside of the pipe, gives a secondary seal
against the inside of the fitting.
FLEXI HOSES
PLUMBING FITTINGS
PART NO. SIZE MM
PART NO.SIZE MM
Suitable for central heating systems.
PART NO.SIZE MM
PEM0410W 10
PEM0415W 15
PEM0422W 22
PEM0428W 28
Suitable for central heating systems.
PEM201510W 15 x 10
PEM202215W 22 x 15
Suitable for central heating systems.
PART NO.SIZE MM
JG601B 20 x 15
JG603B 25 x 15
JG602B 25 x 22
Cold water only.
Used to connect PE Pipe to Speedfit
or to Table X or Y Copper.
Taken from the Speedfit Underground Fittings
Range, see separate section for details and
Technical Specification.
PEM0310W 10
PEM0315W 15
PEM0322W 22
PEM0328W 28
EQUAL STRAIGHT CONNECTOR
PART NO.PIPE STEM
PEM221010W 10 x 10
PEM221015W 10 x 15
PEM221515W 15 x 15
PEM222222W 22 x 22
PART NO.SIZE MM
PEM0210W 10
PEM0215W 15
PEM0222W 22
PEM0228W 28
Suitable for central heating systems
Please note a Collet Cover cannot be used
on a Speedfit end assembled with the stem
of a 22mm Stem Elbow.
Suitable for central heating systems.
PART NO.SIZE MM
PEM3015BW 15 x 10 x 10
PEM3015AW 15 x 15 x 10
PEM3022CW 15 x 15 x 22
PEM3022BW 22 x 15 x 15
PEM3022DW 22 x 15 x 22
PEM302210AW 22 x 22 x 10
PEM3022AW 22 x 22 x 15
PEM3028BW 28 x 22 x 22
PEM302815AW 28 x 22 x 28
PEM3028AW 28 x 28 x 15
PEM3028DW 28 x 28 x 22
Sizes are listed in the following order.
Suitable for central heating systems.
12
3
Provides a swivel
type connection.
PART NO.SIZE
Suitable for central heating systems.
For torque figures see Technical Checklist.
PART NO. SIZE
PSE3210W 10mm x 1/2” BSP
PSE3201W 15mm x 1/2” BSP
PSE3203W 15mm x 3/4” BSP
PSE3202W 22mm x 3/4” BSP
Suitable for central heating systems
Note: Plastic threads are not as strong
as metal threads.
For torque figures see Technical Checklist.
Requires hand tightening only.
With brass swivel nut and sealing washer.
PART NO.SIZE
Suitable for central heating systems.
For torque figures see Technical Checklist.
PART NO.SIZE MM
PART NO.SIZE MM
PL10 10
PL15 15
PL22 22
PL28 28
Suitable for central heating systems.
PEM061510W 15 x 10
PEM062215W 22 x 15
PEM062815W 28 x 15
PEM062822W 28 x 22
PEMSTC1514 15mm x 1/2” BSP
PEMSTC1516 15mm x 3/4” BSP
PEMSTC2216 22mm x 3/4” BSP
PEMBTC1514 15mm x 1/2” BSP
PART NO.SIZE MM
PSE4610W 10
PSE4615W 15
PSE4622W 22
Suitable for central heating systems.
PART NO. SIZE MM
CM0715S 15
CM0722S 22
CM0728S 28
Suitable for cold water tanks only.
Requires hand tightening only.
Maximum wall thickness of tank 4mm.
Suitable for central heating systems.
With brass swivel nut and sealing washer.
REDUCING STRAIGHT COUPLER
PE-COPPER COUPLER
EQUAL ELBOW
STEM ELBOW
EQUAL TEE
REDUCING TEE
TANK CONNECTOR
STOP END
REDUCER
FEMALE COUPLER - TAP CONNECTOR
STRAIGHT TAP CONNECTOR
BENT TAP CONNECTOR
PLUG
09 10
PART NO.SIZE MM
PEM532210W 22 x 22 x 10
PEM532215W 22 x 22 x 15
Sizes are listed in the following order.
Suitable for central heating systems.
12
3
STEM TEE
PART NO.SIZE
NC471 1/2 id x 15mm
NC2324 3/4 id x 22mm
Suitable for central heating systems.
Connects imperial to metric pipe.
PART NO.SIZE MM
CM-SC-15S 15
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PART NO.SIZE
NC448 15mm x 1/2"
NC473 22mm x 3/4"
NC737 22mm x 1/2"
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PART NO.
JG- ROP
Creates a neat outlet for 10mm supply pipes to a radiator. To be
used with single gang 25mm steel K0 boxes to BS 4662, fitted
with rubber grommet.
CONVERSION CONNECTOR
SLIP CONNECTOR
HOSE CONNECTOR
RADIATOR OUTLET PLATE
PART NO.SIZE
MM
JGRAIL4 4 Zone 22 x 15
JGRAIL6 6 Zone 22 x 15
JGRAIL12 12 Zone 22 x 15
BRASS RAIL MANIFOLD
PART NO.SIZE MM
SFM512210S 22 x 10
Suitable for central heating systems.
4 WAY MANIFOLD
PART NO.SIZE MM
SFM522210S 22 x 10
SFM522215S 22 x 15
Suitable for central heating systems.
4 PORT RAIL MANIFOLD
PART NO.SIZE
MM
JGMAN2-R 2 Port 3/4” x 15
JGMAN3-R 3 Port 3/4” x 15
JGMAN4-R 4 Port 3/4” x 15
JGMAN2-B 2 Port 3/4” x 15
JGMAN3-B 3 Port 3/4” x 15
JGMAN4-B 4 Port 3/4” x 15
BRASS MANIFOLD
Red Handle
Blue Handle
Blanking plug supplied
with each manifold.
Control knobs have the means to be labelled
ʻBasinʼ, ʻBathʼ, ʻSinkʼ, ʻShowerʼ, ʻToiletʼ, ʻBidetʼ
or ʻWashing Machineʼ.
PART NO. SIZE
MM X BSP
Hot and cold water only, maximum 65
º
c.
Protect from sunlight and frost.
PLASTIC BACK PLATE ELBOW
15PWB 15 x 1/2"
MANIFOLDS
FLX43P 15 x 1/2"
FLX34P 10 x 1/2"
FLX35P 15 x 3/8"
FLX15P 15 x 1/2"
FLX16P 15 x 3/4"
FLX22P 22 x 3/4"
FLX18P 15 x 1/2"
FLX20P 15 x 3/4"
FLX19P 22 x 3/4"
FLX23
Full Bore
22 x 3/4"
FLX40 15 x 1/2"
FLX42 15 x 3/4"
FLX41 22 x 3/4"
Not suitable for central heating systems.
Hot and Cold water only, 65°C max.
500mm long
300mm long
PART NO.SIZE MM
FLX33P 15 x 10
FLX17P 15 x 15
FLX26P 22 x 22
FLX21P 15 x 15
FLX27P 22 x 22
FLX47 15 x 15
300mm long
500mm long
BRAIDED FLEXI HOSES
PART NO.SIZE
MM X BSP
BRASS VALVE
FLX24P 15 x 1/2”
FLX25P
Full Bore
22 x 3/4”
FLX31P 15 x 1/2”
FLX38P 15 x 3/4”
FLX32P
Full Bore
22 x 3/4”
PLASTIC VALVE
FLX37P 15 x 1/2”
FLX39P 22 x 3/4”
PLASTIC VALVE WITH HANDLE
FLX37-H 15 x 1/2”
FLX39-H 22 x 3/4”
300mm long
500mm long
BRASS FITTINGS
PART NO.SIZE
MM X BSP
Converts Speedfit to male thread.
PART NO. SIZE
MM X BSPT
MW051504N 15 x 1/2”
MW052206N 22 x 3/4”
MW052818N 28 x 1” BSP
Suitable for central heating systems.
Manufactured in DZR Brass.
PART NO. SIZE
MM X BSPT
MW011504N BRASS 15 x 1/2”
MW012206N BRASS 22 x 3/4”
MW012808N 28 x 1”
Suitable for central heating systems.
Manufactured in DZR Brass.
PART NO.SIZE
MM X BSP
22CFA 22 x 1
Suitable for central heating systems.
Manufactured in DZR Brass.
PART NO.SIZE
MM X BSP
22CMA 22 x 1
Suitable for central heating systems.
Manufactured in DZR Brass.
SPEEDFIT X UNION NUT
SPEEDFIT X SPEEDFIT
SPEEDFIT X UNION NUT WITH SERVICE VALVE
BRASS MALE COUPLER
BRASS BACK PLATE ELBOW
BRASS MALE STEM ADAPTOR
BRASS MALE CYLINDER ADAPTOR
BRASS FEMALE CYLINDER ADAPTOR
11 12
150mm long
1000mm long
PART NO.SIZE
MM X MALE
FLX48 12 x M10
FLX28 15 x M10
FLX29 15 x M12
FOR MONOBLOC MIXERS
PART NO.SIZE
MM X BSP
PART NO.SIZE
MM X BSP
FLX36P 15 x 1/2”
ELBOW PATTERN
300mm long
300mm long
300mm long
500mm long
PART NO.SIZE
MM X BSP
FLX49 15 x 3/8”
SPEEDFIT X MALE THREAD
300mm long
PART NO.SIZE MM
SPEEDFIT X UNION NUT
SPEEDFIT X PLAIN STEM
200mm long
SPEEDFIT X SPEEDFIT WITH SERVICE VALVE
BRASS VALVE
FLX44P 15 x 15
FLX45P 15 x 15
PART NO.SIZE
MM X MALE
FOR MONOBLOC MIXERS
PART NO. SIZE
MM X BSP
SPEEDFIT X UNION NUT WITH SERVICE VALVE
PART NO.PIPE STEM
WFLX51 15 15
IDENTITY DISCS
PART NO.PACK QTY
WHITE PVC FLEXI HOSES
WFLX15 15 x 1/2”
WFLX16 15 x 3/4”
WFLX22 22 x 3/4”
WFLX18 15 x 1/2”
WFLX20 15 x 3/4”
WFLX19 22 x 3/4”
PART NO.SIZE
MM X BSP
300mm long
500mm long
PART NO. SIZE MM
WFLX17 15 x 15
SPEEDFIT X SPEEDFIT
300mm long
WFLX36 15 x 1/2”
ELBOW PATTERN
300mm long
PART NO. SIZE
MM X BSP
PART NO.SIZE
MM X BSP
10MC (1/2) BRASS 10 x 1/2”
15MC (1/2) BRASS 15 x 1/2”
22MC (3/4) BRASS 22 x 3/4”
MW012818N 28 x 1”
PLASTIC VALVE WITH HANDLE
WFLX37-H 15 x 1/2”
WFLX39-H 22 x 3/4”
300mm long
WFLX28 15 x M10
WFLX29 15 x M12
300mm long
FLX - RED 10
FLX - BLU 10
1000mm long
SPEEDFIT X PLAIN STEM
300mm long
PART NO.PIPE STEM
FLX53 15 15
Not suitable for central heating systems.
Hot and Cold water only, 65°C max.
For handles on service valves.
PART NO.SIZE
MM X BSP
MW501514N 15 x 1/2”
MW502216N 22 x 3/4”
Suitable for central heating systems.
Manufactured in DZR Brass.
Converts Speedfit to female thread.
BRASS FEMALE STEM ADAPTOR
15WB 15 x 1/2"
22WB 22 x 3/4"
Manufactured in DZR Brass.
Suitable for central heating systems.
SHORT VERSION
15WB2 15 x 1/2"
Manufactured in Brass.
Suitable for central heating systems.
VALVES
PART NO.SIZE MM
15 ESOT 15
PART NO.SIZE
15 APT 15mm x 3/4" BSP
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
For torque figures on plastic threads
please see Technical Checklist.
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PART NO.SIZE MM
15STV 15
22STV 22
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PART NO.SIZE MM
15SV 15
22SV 22
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PART NO.SIZE MM
15BDC 15
PART NO.SIZE MM
15DCV 15
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PART NO.SIZE MM
10HSV 10
15HSV 15
22HSV 22
Suitable for central heating systems.
Suitable for central heating systems.
Manufactured in DZR Brass.
Please note a collet cover cannot be used on
a Speedfit end assembled with a draincock.
Draincocks can be fitted with a standard
fitting fitted with a collet clip.
When using with Twist and Lock Fittings
the fitting must be locked.
PART NO.SIZE
15PTSV 15 x 1/2”
22PTSV 22 x 3/4”
Suitable for central heating systems.
PART NO.SIZE MM
15HSV-BRASS 15
Suitable for central heating systems.
PIPE AND PIPE ACCESSORIES
PART NO.SIZE MM
CM1810S 10
CM1815S 15
CM1822S 22
CM1810W 10
CM1815W 15
CM1822W 22
CM1810R 10
CM1815R 15
CM1822R 22
CM1810B 10
CM1815B 15
CM1822B 22
Suitable for central heating systems.
White and grey collet clips prevent accidental
release of pipe from standard fittings.
Red and blue clips provide colour coding of pipe,
they should not be used to prevent accidental
release of pipe.
PART NO.SIZE MM
PKM1910W 10
PKM1910R 10
PKM1910B 10
AM1915W 15
PM1915R 15
PM1915B 15
AM1922W 22
PM1922R 22
PM1922B 22
Available in white, red or blue
Suitable for central heating systems
PART NO. SIZE
15BPEX-20x2L 15mm x 2m
15BPEX-20x3L 15mm x 3m
15BPEX-20x6L 15mm x 6m
22BPEX-20x2L 22mm x 2m
22BPEX-20x3L 22mm x 3m
22BPEX-20x6L 22mm x 6m
28BPEX-10x3L 28mm x 3m
28BPEX-10x6L 28mm x 6m
Suitable for central heating systems.
Straight lengths
The pipe has an inner barrier to
stop the ingress of atmosphere.
*By special order only.
PART NO.SIZE MM
TSM10N 10
TSM15N 15
TSM22N 22
TSM28N 28
Suitable for central heating systems.
To be used when connecting Speedfit Pipe
to a compression fitting.
See Page 16.
PART NO.SIZE
10BPEX-25C 10mm x 25m
10BPEX-50C 10mm x 50m
10BPEX-100C 10mm x 100m
15BPEX-25C 15mm x 25m
15BPEX-50C 15mm x 50m
15BPEX-100C 15mm x 100m
15BPEX-120C 15mm x 120m
15BPEX-150C 15mm x 150m
22BPEX-25C 22mm x 25m
22BPEX-50C 22mm x 50m
Suitable for central heating systems.
Coils
The pipe has an inner barrier to
stop the ingress of atmosphere.
British Gas accepted for water
pipe in vented and sealed central
heating systems.
PART NO.SIZE MM
STS10 10
STS15 15
STS22 22
STS28 28
Suitable for central heating systems.
To be used only when connecting
Speedfit Pipe and Speedfit Fittings
to enhance the sealing security of
the connections. See page 05.
PART NO. SIZE
BLACK
15BLK CON-25C 15mm x 25m
15BLK CON-50C 15mm x 50m
22BLK CON-25C 22mm x 25m
22BLK CON-50C 22mm x 50m
RED
15RED CON-50C 15mm x 50m
22RED CON-50C 22mm x 50m
BLUE
15BLU CON-50C 15mm x 50m
22BLU CON-50C 22mm x 50m
To be used when Speedfit Pipe is laid
in Concrete and Masonry, see section
on page 20.
*
PART NO. SIZE
CONELB FITS 10, 15 & 22mm
STOP VALVE
WASHING MACHINE TAP
EMERGENCY SHUT OFF TAP
DOUBLE CHECK VALVE
PLASTIC SERVICE VALVE
BRASS SERVICE VALVE
BRASS CHROME PLATED SERVICE VALVE
BRASS CHROME PLATED SERVICE VALVE
WITH TAP CONNECTOR
BRASS DRAIN COCK
PEX BARRIER PIPE
PEX BARRIER PIPE
SUPERSEAL PIPE INSERT
PIPE INSERT
CONDUIT PIPE
CONDUIT ELBOW
COLLET COVER
COLLET LOCKING CLIP
PART NO.SIZE MM
15BSC 15
Only suitable for central heating.
Head and Body manufactured in DZR Brass.
BRASS STOP TAP
13 14
Grey
PART NO.SIZE MM
10BV 10
15BV 15
22BV 22
Suitable for central heating systems.
BRASS CHROME PLATED BALL VALVE
White
Red Blue
PART NO.SIZE
15BPB-25C 15mm x 25m
15BPB-50C 15mm x 50m
15BPB-100C 15mm x 100m
15BPB-120C 15mm x 120m
15BPB-150C 15mm x 150m
22BPB-25C 22mm x 25m
22BPB-50C 22mm x 50m
Suitable for central heating systems.
Coils
The pipe has an inner barrier to
stop the ingress of atmosphere.
British Gas accepted for water
pipe in vented and sealed central
heating systems.
POLYBUTYLENE BARRIER PIPE
Each Valve has a red and a blue indice.
PART NO.SIZE
15SVSTC 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PLASTIC SERVICE VALVE WITH TAP CONNECTOR
PART NO.SIZE
15SVBTC 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PLASTIC ANGLE SERVICE VALVE
WITH TAP CONNECTOR
PART NO. SIZE
15PIP-50C-E 15mm x 50m
22PIP-50C-E 22mm x 50m
PIPE IN PIPE
PART NO.SIZE MM
PLASTIC BALL VALVE
Not suitable for central heating systems.
Each Valve has a red and a blue indice.
15SV-H 15
22SV-H 22
Grey
White
Grey
White
PART NO. SIZE
15SVSTC-W 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PART NO.SIZE
15SVBTC-W 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
Water-replenishing ring mains are typically used in hotels
and hospitals. They are maintained at a constant high
temperature to supply hot water to distribution pipes to
wards or hotel rooms which may be some way from the
heat source.
These systems are very different from more conventional
domestic hot water and central heating systems.
Speedfit Products cannot be used on ring main systems.
The exception would be those systems designed for
domestic situations which have an intermittent
temperature of less than a maximum of 65ºC. This is in
accordance with BS7291 Parts 1 and 3 Class S.
PART NO.
JG-TS
PART NO.
JG HDC
BLADE-JGHDC
PART NO.SIZE MM
PC15W 15
PC22W 22
PC28W 28
PCSW
For up to 22mm size pipe.
PART NO. SIZE MM
NPC10 10
NPC15 15
NPC22 22
NPC28 28
PART NO.SIZE MM
10CFB 10
15CFB 15
22CFB 22
To help create a tighter bend than
the minimum with unsupported pipe.
PART NO. SIZE MM
JG-BS10 10
JG-BS15 15
JG-BS22 22
For use with Female Coupler/Tap Connector.
PLUMBING SPARE PARTS
PART NO.SIZE MM
PXC 10 10
PXC 15 15
SPF 22 22
PXC 28 28
PXC 10 10
PXC 15 15
PXC 22 22
PXC 28 28
PART NO.SIZE MM
10 EPR 10
15 EPR 15
22 EPR 22
28 EPR 28
PART NO.SIZE
1/2 EPW 1/2
3/4 EPW 3/4
10mm
15mm and 22mm
PART NO.SIZE MM
10RA 10
15RA 15
22RA 22
28RA 28
PIPE AND PIPE ACCESSORIES
For Standard Fittings
For Twist and Locks Fittings
SYSTEM CONNECTIONS
The Speedfit Range includes couplers to connect
Speedfit Pipe to 1/2” to 1” BSP and BSPT. See page 12.
Many but not all compression fittings are suitable for use
with plastic fittings and pipe. Users should therefore
check for compatibility. Compression fittings with short
tube stop depth or brass olives should not be used with
plastic fittings or pipe.
When using compression fittings with Speedfit Pipe, a
Standard Pipe Insert (prefix TSM) must be used to
withstand the compressive pressure of the olive. The olive
must be located within the the length of the pipe insert
and the pipe fully inserted into the fitting. The connection
should not need more than 2 full turns after the olive has
gripped the pipe. JG Speedfit recommend the use of soft
copper olives.
In modern properties, water enters a building usually in
blue MDPE (medium density polyethylene) pipe. In order
to comply with Water Regulation Schedule 2.10, the
internal plumbing system should be connected via a
Speedfit Stop Valve (Part Nos. 15STV and 22STV) in
conjunction with a PE-Copper Coupler from the Speedfit
range of Underground Fittings.
Speedfit fittings can be connected onto chromium plated
copper pipe if the chromium plating is completely
removed to the full depth of the fitting. To ensure
maximum grip, the fitting of a collet clip is recommended.
Connection of Speedfit
pipe to supply pipe of other
materials should be via a
stop tap with a 15mm or
22mm compression outlet.
Compression fitting Standard Pipe insert
Olive
Speedfit Pipe
with Superseal Pipe Insert
Stop valve
Copper pipe
PE copper coupler
MDPE pipe with
Pipe Insert
Collet clip
Speedfit Pipe
Speedfit pipe should never be connected directly to a boiler.
Although most modern boilers have a high limit
thermostat, residual heat can be conducted by the heat
exchanger. Therefore, Speedfit recommend a minimum of
1 metre from the boiler casing should be run in copper
pipe unless otherwise stated in the boiler manufacturers
installation literature.
A gravity primary circuit operating on an uncontrolled
cooking range or solid fuel boiler should be run entirely in
copper and the heating circuit run in copper for the first metre
.
Refer to BS 5955: Part 8 for further clarification.
All appliances should have safety devices to make sure
they cannot operate above the working temperature and
pressure range set out in our Technical Checklist on page
29. If safety devices are not incorporated within the
appliance then external controls will be needed.
Water meters (and other devices) can contain check
valves that prevent the expansion of heated water back
down the main supply from a combi boiler. If plastic pipe
is to be used, a suitable expansion vessel must be fitted.
This is especially important to consider if a water meter is
fitted retrospectively. Speedfit do not recommend the use
of plastic pipe on the main supply between a water meter
and a combi boiler if an expansion vessel is not fitted.
Speedfit Products should not be fitted to a sealed system
oil boiler, back fired boiler or other uncontrolled heat source.
Please also see Drop-Pipe Systems on page 17 and
System Commissioning and Flushing on page 21.
Ensure nut and olive are in place before inserting pipe insert.
It is not possible to connect Speedfit fittings to Stainless
Steel Pipe.
Fittings to connect imperial
pipe to metric pipe are
shown on page 10.
RELEASE AID
COLD FORMING BEND
BENDING SPRING
PIPE CUTTER
HEAVY DUTY PIPE CUTTER
PIPE CLIPS AND SPACERS
NAIL CLIP
COLLETS
EPDM ‘O’ RING
THREAD WASHER
CONNECTION TO COMPRESSION FITTING
CONNECTION TO IMPERIAL PIPE AND FITTINGS
CONNECTION TO CHROME-PLATED COPPER PIPE
CONNECTION TO MAINS SUPPLY
CONNECTION TO RING MAINS
CONNECTION TO BOILERS
Speedfit can be used on sealed and open vented heating
systems, where boilers are either heating a hot water
storage cylinder or instantaneous hot water such as a
combination boiler. The temperature and pressure limits
of the system must not exceed the maximum values stated
under the heading ‘Working Temperatures and Pressures’.
When using a traditional copper vented cylinder Speedfit
pipe and fittings can be installed with direct connections
to the cylinder.
As shown in the Product Range List, the Speedfit range of
fittings includes valves, taps, adaptors and connectors for
the plumbing of all typical domestic appliances and fittings.
CONNECTING TO OTHER PLUMBING FIXTURES
CONNECTION TO CYLINDER & WATER HEATERS
15 16
For up to 28mm size pipe.
Allows a firmer grip on the
collet when removing pipe.
PART NO.SIZE MM XM
JGTAPE 50 x 45
FOIL TAPE
Metallic tape to meet NHBC requirements
for plastic pipe to be detected inside walls.
The Speedfit range includes a Double Check Valve
(Part No 15DCV) to enable installers to comply with Water
Regulation
Schedule 2.15,
thus preventing contamination
of water arising from
back siphonage,
backflow or
cross connection.
Washer
Hole dia.
15mm pipe 29mm
22mm pipe 36mm
28mm pipe 46mm
Cold water tank
The minimum distance to make a solder connection on
copper pipe inserted into a Speedfit Fitting is 450mm
(18 inches). Ensure that any residual flux solder is not
allowed
to come in contact with the fitting. That same
measurement
is the safe distance to use a freezer kit to
Speedfit Pipe.
Care should be taken when designing and installing a
central heating system where radiators are supplied by
pipe work which drops from an upper floor.
With this kind of system it is possible to trap air in the
upper floor pipe work. When the boiler is fired the increase
in pressure within the pipe caused by expanding air could
cause the pipe to burst.
It is therefore essential that the system be designed so
that any air can be removed from the system either
automatically or manually by installing automatic or
manual air vents at the highest points of the system.
Speedfit pipe should not be used to provide the discharge
from unvented cylinders, unvented water heaters and sealed
systems via the temperature relief and pressure relief values.
Speedfit recommend that mains supply pipework to unvented
water heaters (up to 15ltr capacity), be run in metal pipes.
Speedfit pipe should be connected to circulating pumps,
motorised valves in accordance with the section in this
book headed, “Connecting Plastic Pipe To Compression
Fittings”. If Speedfit pipe is not mounted on a supporting
structure, the pipe must be clipped close to the components’
connections to ensure adequate support and to assist in
the reduction of vibration.
For heavier equipment, ensure that appropriate metal
brackets provide full and independent support of the
components and that it does not rely solely on the pipework
for support.
To install the Speedfit Tank Connector, unscrew the nut
and push the body of the fitting through the tank hole with
the washer on the inside of the tank.
Hand tighten the nut onto the body. Push the pipe into
the connector.
Note: Hand tightening the nut onto the body is all that is
required. Further mechanical tightening will damage the fitting.
Maximum wall thickness of tank 4mm
IEE Guidance Note 7 provides useful guidance on the
design of electrical installations where there is increased
risk of electric shock. It recognises that the requirement
for supplementry bonding may be relaxed where metal
taps and plastic pipes supply other bathroom fittings.
Similarly a metal bath or radiator not connected to an
extraneous-conductive-part is not required to be connected
to the local supplementry conductors.
Metal
Pipe
Metal
Pipe
Speedfit Pipe and Fitting
Clip Clip
Earth Lead
The most common way of running pipework to a radiator
is to run both flow and return pipes central to the
radiator position.
Once the plasterboard is installed the pipes are passed
through the Speedfit Radiator Outlet Plate to exit
plasterboard without the need of unsightly holes.
Metal reducing sets which convert radiator valves from
15mm to 10mm are not suitable for use with Speedfit
Fittings or Pipe as they can cause damage to the plastic.
Pipe Supplementary Bond Comments
Material Required Between
Earth terminals of
protective conductors of
class I and of class II
equipment and accessible
exposed conductive parts
of the building structure.
Hot water pipe, central
heating pipes, earth
terminals of protective
conductors of class I and
class II equipment and
accessible exposed
conductive parts of the
building structure.
Central heating pipes, the
earth terminals of
protective conductors of
class I and class II
equipment and access to
exposed conductive parts
of the building structure.
All metal pipes,
earth terminals of
protective conductors
class I and class II
equipment, and accessible
exposed conductive parts
of the building structure.
All metal pipes,
earth terminals of
protective conductors of
class I and class II
equipment, and accessible
exposed conductive parts
of the building structure.
Bonding of metal taps
metal radiatorsor metal
baths is not required
unless the bath is
connected to the
metallic building structure.
A bond is not required
to the taps either hot
nor cold, or to metal
baths unless connected
to the metallic
building structure.
Bonding of metal water
taps is not required,
nor metal baths unless
connected to the metallic
building structure.
Metal pipes themselves
can be used as bonding
conductors if joints are
metal to metal and
electrically continuous.
Metal central heating
radiator does not
require bonding.
Cold Hot Central
Water Water Heating
P PP
PMM
PPM
MMM
MMP
P= Plastic M= Metal NB: All Waste Pipes are plastic.
1. Supplementary bonding is carried out to the earth terminal
of protective conductors of class I and class II equipment
within the bathroom. A supplementary bond is not run
back to the main earth.
2. Metal window frames are not required to be supplementary
bonded unless they are electrically connected to the
metallic structure of the bonding.
3. Metal baths supplied by metal pipes do not require
supplementary bonding if all the pipes are bonded and
there is no other connection of the bath to earth.
4. All bonding connections must be accessible and labelled
“Safety Electrical Connection - Do Not Remove”.
DROP-PIPE SYSTEMS
DISCHARGE PIPES
WATER HEATERS
CONNECTION TO PUMPS AND VALVES
CONNECTION TO COPPER PIPE
CONNECTING TO COLD WATER STORAGE TANK
PREVENTING BACK FLOW
RADIATOR CONNECTIONS
ELECTRICAL CONTINUITY CONT’D
SUPPLEMENTRY BONDING TO BATHROOMS
INSTALLING PIPEWORK
Speedfit Barrier Pipe is manufactured to BS 7291 Parts 1,
2 and 3 Class S and is Kitemarked.
The pipe is available in coils and straight lengths. See
pages 14. Pipe markings are spaced to aid the making of
a good connection when using a Superseal Pipe Insert.
15mm B-PEX to BS7291 : Part 3 : 1990 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C
It is made up of 5 layers, the
centre of which is a blue
coloured oxygen barrier
which prevents the ingress
of air into the system, thereby
reducing the effect of corrosion
on metal components.
Because of it’s low thermal conductivity, when carrying
hot water, Speedfit Pipe is cooler and therefore safer to
touch. Relatively low heat loss through radiation means that
a system retains it’s heat longer and delivers hot water
more quickly and with less wastage than a metal system.
SPEEDFIT BARRIER PIPE
For general guidance on pipework sizing, please refer to
BS6700 or the Institute of Plumbing Engineering Services
Design Guide. Speedfit fittings are suitable for pipes
within ±0.1mm of nominal size. They can be used with
copper pipe to BS EN 1057 or Speedfit plastic pipe.
The Product Range List shows the fittings available for
reducing pipe diameters within the system.
Speedfit pipe is available in straight lengths and coils.
Pipe Diameter
Straights 2m - 15mm 22mm -
3m - 15mm 22mm 28mm
6m - 15mm 22mm 28mm
Coils 25m 10mm 15mm 22mm -
50m 10mm 15mm 22mm -
100m 10mm 15mm --
120m - 15mm --
150m - 15mm --
PIPEWORK SIZING
17 18
22mm Barrier-PB to BS7291-2 2001 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C
The pipes exit a single
gang box (fitted with rubber
grommets)
located at the
mid height of the finished
radiator position. This also
provides a fixed point for
other trades to work to and
reduces the risk of damage
to the pipework.
Unvented pressurised cylinders can be installed using
Speedfit Pipe and Fittings. However, insertion depths on
compression joints that form part of the cylinder must be
checked prior to installation and the use of standard pipe
inserts (Prefix TSM) is recommended.
In accordance with current U.K. Building Regulations
(Part G), discharge pipes from temperature and/or pressure
relief valves must be run in metal pipework.
Speedfit connections to combined Cylinder/Boiler
units and Thermal Storage Units must be made outside
the casing unless otherwise stated in manufacturers
installation literature.
CONNECTION TO CYLINDER & WATER
HEATERS CONTINUED
The plumbing or heating system installer should have
these aspects checked to ensure compliance with current
IEE regulations. If in doubt please contact the Speedfit
Technical Advisory Service or your local Electricity Authority.
ELECTRICAL CONTINUITY
UNVENTED PRESSURISED CYLINDERS
Unvented Pressurised Cylinders can be installed using
Speedfit pipe and fittings. However if the safety
parameters of the cylinder exceed those of the pipe and
fittings it is possible to fit a pressure reduction valve on
the out going hot supply pipe. This will not interfere with
any other cylinder safety devices demanded by
regulations as they are all fitted in the incoming side of the
cylinder. Run a short length of copper pipe from the
cylinder connection (about 150mm - 300mm) then fit a
Honeywell DO5F pressure reduction valve. This will
protect the pipe and fittings from excessive pressure in
the event of boiler / cylinder malfunction. The factory
fitted temperature / pressure relief valve on the cylinder
will discharge below 100˚C therefore protecting the pipe
from excessive temperature.
JG Speedfit aluminium foil tape can be used to fulfil the
NHBC requirements for the identification of location of
plastic pipes in or behind a wall surface by a metal
detector. It features a bright aluminium finish, rubber/resin
high-tack adhesive and quality siliconised backing paper
to allow the easy handling of short, cut lengths.
D
DO
O
N
NO
OT
T
s
st
ti
ic
ck
k
t
th
he
e
t
ta
ap
pe
e
t
to
o
t
th
he
e
S
Sp
pe
ee
ed
df
fi
it
t
p
pi
ip
pe
e
o
or
r
f
fi
it
tt
ti
in
ng
gs
s
o
or
r
t
th
ho
os
se
e
o
of
f
a
an
ny
y
o
ot
th
he
er
r
m
ma
an
nu
uf
fa
ac
ct
tu
ur
re
er
r.
.
METAL FOIL TAPE
There are two types of pipe clip in the Speedfit range.
Firstly, a nail clip is used for fixing to timber
when running concealed pipe work i.e.
underfloor or in a roof space . This clip takes
less time to fit and is compact which allows
pipework to be fixed close together when
space is at a premium.
Pipe clips should not be fitted any closer than 60mm from
the end of the fitting to allow for expansion. Pipes should
always be adequately supported to prevent undue stress
or side load on the fittings.
The second type uses a screw and therefore
takes a little longer to fix. When pipes are
required to cross over, it is possible to add
a spacer to the clip. This will give room
between the pipe and the wall to allow the
pipes to cross over. If pipework needs to be
insulated, using the spacer will give room for
the lagging to be applied.
The flexibility of Speedfit pipe gives it the ability to be
threaded through concealed or inaccessible spaces
without disruption to surrounding structures, making
major savings in installation time.
Pipework can be “cabled” through drilled holes in joists
and rafters. Therefore, pipework can be installed after
floorboards have been laid, working below the floor
before the ceiling is installed.
This makes site work far safer as the installer does not
have to balance on open joists with the risk of dropping
tools or equipment on other people below.
Instructions on the drilling of joists is given in the Building
Regulations Approved Document A, and summarised as
follows:
1. Holes should be no greater than 0.25 of the depth of the joist.
2. Holes should be drilled at the neutral axis.
3. Holes should not be less than 3 diameters (centre to centre) apart.
4. Holes should be located between 0.25 and 0.4 times the span
from the support.
Max. dia. of holes = 0.25D
Joist
Clips
Speedfit pipe
This will also eliminate the risk of damage by floorboard
nails. There is no need for dry runs since pipe can be cut
and connections made in-situ.
Rigid pipe, such as copper, can only be fed under floor in
short lengths. However, Speedfit pipe, being flexible, can
run from one fitting to another without having to install a
connector in between.
Speedfit needs no jointing materials, eliminating the risk of
fire from the use of a blowlamp, solder and flux
.
Min 3 x hole dia.
D
The insulation requirements for Speedfit pipe are the same as
those for copper and should comply with BS6700 and BS5422.
For general guidance on pipework sizing, please refer to
BS6700 and BS5449 or the Institute of Plumbing
Engineering Services Design Guide. Speedfit fittings are
suitable for connection to pipe sizes within ± 0.1mm of
nominal size.
The maximum heat carrying capacity and flow of Speedfit
pipe, based on 1.2m/s velocity and an 11ºC temperature
drop is shown in the table below.
Pipe size Max Capacity Max Flow Headloss
KW litres/sec m/m pipe
10mm 1.948 0.042 0.283
15mm 5.941 0.129 0.139
22mm 13.604 0.295 0.084
28mm 21.991 0.478 0.062
Pipe Diameter Clip Spacing
Horizontal Run Vertical Run
10 - 15mm 300mm 500mm
22mm 500mm 800mm
28mm 800mm 1,000mm
For surface mounted pipes
Several types of joists are available and Speedfit recommends
that specific manufacturers details are consulted.
However, the following can be used for general guidance.
Holes may be located vertically anywhere in the web,
but leave 3mm web at the top and/or bottom of hole.
Do not cut into joist flanges when cutting the web.
If more than one hole is to be cut in the web, the
distance between the edges of the holes must be at
least 2x diameter of the largest hole.
Generally joists are manufactured with 38mm
perforated knockouts in the web at approximately
300mm centres along the length of the joist.
PIPE SUPPORT AND CLIPPING
RECOMMENDED CLIP SPACING
PIPE SIZING
PIPEWORK INSULATION
CONCEALED PIPEWORK
TRADITIONAL JOISTS
TIMBER I BEAM JOISTS
Speedfit is well suited for steel frame construction and
care should be taken when installing the pipework.
All runs should be installed through preformed holes in the
structure and protected by a rubber or plastic grommet.
Where clipping of pipework is restricted, cable ties may
be used to secure the pipe.
As with all installations, make sure that any pipework passing
through walls and floors does not affect the fire resistant
properties of the structure.
Speedfit pipework can be easily cabled through studwork
and within wall systems as well as behind “dot and dab”
plasterboard installations. Speedfit 10mm Barrier Pipe is
most commonly used to feed radiators.
If incorporating fittings in this way, collet covers or collet
clips must be used with the Standard range of fittings.
To prevent surface damage to the plaster caused by
expansion and contraction of Speedfit pipes, it is
important to ensure that all Speedfit pipework is
channelled into the wall and protected with appropriate
sleeving. Alternatively, the pipework can be surface
mounted and boxed in if required for aesthetic appearance.
Speedfit is well suited for timber frame construction.
Ensure that the structural integrity is not compromised
when installing the pipework.
If the pipe passes through an external wall, care must be
taken not to damage the vapour barrier and should be
installed on the inside of the thermal insulation layer.
If this is not possible, the use of conduit should be specified
at the design stage.
Unlike I beam joists, pipe can be cabled anywhere within
the open Web as no drilling is required. However, the top
and bottom flanges must not be notched. Avoid
damaging the outside diameter of the pipe as you cable
through the metal cross web members
.
It is also possible to bend Speedfit Pipe using a standard
pipe bender. The pipe should not be heated with a
blowlamp or hot air gun.
Minimum bend radii for Speedfit pipe are as follows:
Min Radius Pipe Diameter
10mm 15mm 22mm 28mm
with Cold Forming Bends 30mm 75mm 110mm -
with Clips 100mm 175mm 225mm 300mm
For bends of radii smaller than those shown, standard
elbow fittings are recommended.
Gentle bends can be made with pipe clips on either side
of the curve, positioned to maintain the bend radius.
Tighter bends can be achieved
by using the cold forming
bends shown on page 15.
Internal Bending Springs are
available in 10mm to 22mm
sizes, see page 15.
PIPE BENDING
Speedfit pipe and fittings can be laid in concrete and
masonry providing they are installed in conduit pipe with
access boxes for the fittings. As stated in Water
Regulation Schedule 2.7 and BS 8000 : Part 15, fittings
and pipe should be removable for possible replacement.
Insulation is also recommended to protect against heat
loss and the effects of frost.
Speedfit Conduit Pipe is supplied
in either 15mm or 22mm in coil
lengths of 25m or 50m. The flexible
convoluted pipe has an outside
diameter of 24mm and 30mm.
On long exposed runs of pipework, the expansion of
Speedfit pipe when warm (1% on length between 20 to
82°C) can cause it to sag between clip fixings. When this
is undesirable, pipework can be boxed in or replaced with
rigid copper pipe. Speedfit pipe and fittings are stabilised
to withstand limited exposure to ultra-violet radiation in
sunlight but are not designed for permanent direct
exposure. Under such conditions painting or lagging is
required. Pipe and fittings should also be lagged to
prevent frost damage.
Only water or oil based paints should be used. Do not
allow Speedfit fittings to come into contact with cellulose
based paints, paint thinners or strippers, solder flux or
acid based descalents or aggressive cleaning products. If
there is a risk of any chemical treatments coming into
contact with Speedfit, please contact the Technical Advisory
Service first to check compatibility.
JG Speedfit does not recommend that fluxes of any type
come into contact with our pipe and fittings. However, if
fluxes are to be used in an environment where Speedfit
is installed then we recommend installers use non-acidic
and zinc chloride free fluxes such as Fernox Flux.
Properly installed, Speedfit pipes are virtually silent in
operation and do not resonate; they absorb the acoustic
vibrations and pressure waves created by cavitations,
water hammer, float operated valve oscillation and other
hydraulic effects. The inherent flexibility of Speedfit pipe
effectively eliminates these troublesome problems, including
those that occur when, due to thermal expansion, metal
pipes rub against structural members and where long,
straight runs of rigid pipe amplify water borne noise.
CROSS WEB JOISTS
TIMBER FRAMED CONSTRUCTION
STEEL FRAMED CONSTRUCTION
DRY LINED WALLS
WET PLASTER
LAYING OF PIPE IN CONCRETE AND MASONRY
EXPOSED PIPEWORK
CHEMICAL EFFECTS
FLUXES AND SPEEDFIT
ACOUSTIC
19 20
When used in locations vulnerable to rodent attack, all
plastic pipes and fittings should be adequately protected
within sealed ducts.
Speedfit products along with other materials such as
electrical cables may be damaged if rodents are present.
If vermin infestation is suspected then a rodent
exterminator
should take appropriate action
.
No taste, colour, odour or toxicity is imparted to water by
Speedfit components, nor do they promote
microbiological growth.
In accordance with BS7291: Part 1 Clause 6.7, the opacity
of both pipes and fittings allows insufficient light to pass
for the growth of algae
Tests within the Water Regulations Advisory Scheme,
have approved Speedfit pipe and fittings to BS 6920 for
water quality.
On completion of the plumbing and heating system it is
essential that system checking and a hydraulic wet test
takes place. Connections to boilers, radiators and
sanitary ware should first be capped or plugged.
Testing should be carried out at
2 bar for 10 minutes followed by 10
bar for 10 minutes.
This testing combined with other
relevant checks, should reveal most
system problems. Any components
within the system not designed
to take these pressures should
be disconnected.
Before carrying out a pressure test
ensure all Speedfit pipe and fittings
are installed correctly. Speedfit
Barrier Pipe is printed with insertion
marks to help ensure full insertion
has been achieved.
Remember pressure testing is NOT a substitute for
making sure fittings are clean and free of any grit, dirt or
swarf and the pipe is correctly inserted (see Making a
Good Connection, on page 06.
With existing systems, flushing prior to the use of Speedfit
is
essential to remove any harmful contamination or chemical
residues from elsewhere in the system.
For the installation of central heating systems flushing
procedures must be in line with BS7593 code of practice
for treatment of water in domestic hot water heating systems.
Flux residues used in the soldering of capillary fittings are
very corrosive. Dirt and grit, which can enter the system
when Speedfit pipe is being pushed through underfloor or
across a roof space, must be removed.
The JG Speedfit Technical Advisory Service is available to
assist and advise on all aspects of using the Speedfit
system. The service is available between 8.00am and 4.30pm,
Monday to Friday on Telephone No. 01895 425333 and
Fax No. 01895 425350. Products within this Product Guide
are designed for use within UK plumbing and heating
installations or in other countries where similar installation
requirements apply. For information on products suitable
for use in other countries please consult our Technical
Advisory Service.
We take pride in the quality of our products and all complaints
are investigated thoroughly. If you have a problem with a
Speedfit Product please return both fitting and pipe to us
for investigation. We will need at least 50mm of pipe to
ensure an accurate analysis. If there is a suspicion that the
pipe is faulty, please provide marking details from the pipe.
PROTECTION AGAINST RODENTS
BIOLOGICAL
SYSTEM TESTING
SYSTEM COMMISSIONING AND FLUSHING
TECHNICAL ADVISORY SERVICE
Ceiling
24°C
Floor
18°C
2.70
1.70
Ideal
Heating
System
Floor
Heating
System
Radiator
Heating
System
UNDERFLOOR HEATING
The Speedfit Underfloor Heating System has been designed
to be as quick and easy as possible to install with component
parts
manufactured to UK and European standards.
Underfloor heating provides the most comfortable even warmth
of any heating system. It is economical to run and virtually
maintenance free. The principle has been with us since
Roman times but is still the system of choice in some
European countries, accounting for 70% of installations.
The Speedfit System has water being pumped from a
boiler to a pump pack, where it is mixed to approximately
50ºC then distributed via a manifold to heating circuits
made using Speedfit Barrier Pipe. The pipe is laid in
concrete or suspended just below the surface of the floor.
In concrete floors, the pipe is laid on insulation and then
covered with a screed on which can be laid almost any type
of floor covering.
For timber floors, spreader plates are laid between the joists
and the floor decking or on the underside of the floor.
Speedfit Pipe is pushed into the grooves on the plates.
The floor area is typically warmed to between 25ºC and
28ºC, providing an even distribution of heat at only slightly
higher than room temperature. The system is controlled
by one or more thermostats which signal the Pump Pack
when heat is required.
21 22
RADIATOR SYSTEM AND HEAT GRADIENT
UNDERFLOOR HEATING SYSTEM
An Underfloor Heating System heats mainly by radiation.
Radiant energy is emitted by the floor giving an even
distribution of heat. No cold spots, hot ceilings or cold feet.
The overall effectiveness of an UFH heating system can
be seen below.
The heat is concentrated where it is most needed for
comfort and efficiency.
Problem: Burst or melted pipe.
Pipe will be distorted showing either a ‘Parrot beak’ look
or a long opening with the edges of the pipe melted in a
wave shape.
Identification: A ‘Parrot beak’ will have been formed by
the pipe bursting due to the water freezing. If the Pipe has
a melted appearance it will have been subject to a
temperature in excess of 128 degrees Celsius. This will
have been caused by direct contact with a heat source
such as a blowtorch or flue pipe or by water or steam
within the system rising above safety levels.
Problem: A fitting or part of a fitting dissolved - the fitting
may have blown off the pipe and may have missing
component parts.
Identification: The fitting will have failed because of a
chemical attack. The most common attack is from acid
based solder flux running down into the fitting during
soldering of a nearby copper fitting or flux coming into
contact with the fitting in some other way.
Problem: Weep from fitting.
Identification : The pipe has not been fully inserted up to
the pipe stop or one or both of the ‘O’ rings have been
damaged by burrs or sharp edges on the end of pipe. See
‘What Not to Do’ on page 06.
Problem: The fitting has blown off the pipe. Fitting is
missing the collet, the pipe insert is still inside the fitting
after the pipe has come out.
Identification: If this happens on first fix, the most likely
reason is that the pipe has not been fully inserted into the
fitting, up to the pipe stop, and the system has not been
pressure tested.
If the collet (gripping device) is missing everything will
blow out. If the collet is there and the pipe support is still
inside the connector but the pipe has still blown out, this
means that full insertion had not been accomplished.
COMMON PROBLEMS AND IDENTIFICATION
During the commissioning of a heating system, all air
must be removed from the system before the boiler is
allowed to fire. This will ensure pockets of air do not
cause localized overheating within the system as this
could have a detrimental affect on the pipework and
boiler.
For further advice on chemical flushing agents and
inhibitor treatments, the following manufacturers should
be contacted: Fernox Manufacturing Ltd., 01799 550811
or Sentinel Betz Dearborn Ltd., 0151 420 9595.
Ceiling
18°C
Floor
24°C
By contrast, radiators transfer heat from a relatively small
area at a much higher temperature than the space being heated.
The radiator system heats mainly by convection. This
results in the floor being the coolest place in the room,
with the mass of warm air at ceiling level.
The Speedfit Underfloor Heating System offers many benefits
to the consumer. These include:
Installation
It is simple to install, requiring the minimum of installation
effort and little maintenance.
Comfort
The system uses radiant heat, the most comfortable form
of heating, to give a good even distribution of warmth
over the whole room.
Space
The system in unobtrusive and space saving which means
every square metre of floor and wall space can be fully
utilised giving freedom of interior design.
Noise
Compared to radiator systems the system is virtually silent running.
Health
Dust is minimised reducing the problem of house dust
mites. Reduced numbers of hot surfaces and sharp edges
minimise risk of burns or injury.
Economic
Underfloor Heating Systems are designed to operate at
lower temperatures than radiator systems, resulting in
reduced energy consumption and lower heatloss from the
building structure.
Control
The system is easy to control and the small temperature
difference between the floor and air means the system is
virtually self - regulating.
Environment
Underfloor heating is suitable for use with the most energy
efficient and environmentally friendly heating systems
including condensing boilers, solar power and heat pumps.
FEATURES & BENEFITS
The Speedfit Underfloor Heating System is suitable for
most floor finishes, including ceramic tiles, carpets, vinyl
and laminate.
The thermal resistance of floor covering will have a marked
effect on the performance of the heating system.
Advice on the use of floor coverings and their effect on
the performance of a system is laid out in the Speedfit
Underfloor Heating Manual.
FLOOR FINISHES AND COVERING
SPEEDFIT SYSTEM COMPONENTS
Speedfit Underfloor Heating Products have been designed
and are manufactured to European and UK Standards,
including ISO 9001 and DIN4726.
Speedfit Manifolds are manufactured from high quality
DZR brass to the highest UK and European standards.
A unique feature is that connections to the heating pipes
are Speedfit Push Fit, offering much reduced installation
time. Flow and return rails are offset and the angles can
be altered, all making for an easy installation.
The manifolds are complete with adjustable flow gauge,
drain valve and air bleed valve. They are pre assembled
on wall brackets and supplied with screws and plugs.
Manufactured in DZR brass, the pack
consists of a pump, mixing valve and
overheat temperature thermostat.
Offered in PEX or Polybutylene, Speedfit Pipe has an
inner barrier to prevent the ingress of atmosphere, it is
manufactured and Kitemarked to British Standard
BS7291 : Parts 1,2 & 3: Class S.
It is lightweight and flexible making it especially suitable
for underfloor heating installations.
For screed systems, the pipe is attached directly to
insulation with staples, floor clips or mounting rails.
Spreader Plates are available for timber flooring using
either traditional joists or TJI Joists.
A mains operated room thermostat. The temperature is set
manually for ‘daytime’ temperature. A ‘set back’ mode,
reducing the temperature by 4oC, is controlled by a Centralised
or Remote System Timer. The Thermostat has a manual
override for permanent ‘Daytime’ or permanent ‘Set back’
temperature and can be used in conjuncton with a Wet Area
Probe.
Speedfit offer several ways of securing pipe to the
insulation layer in a screeded floor.
23 24
PART DESCRIPTION PACK
NO.QTY
JGUFHMAN4 4 ZONE MANIFOLD 1
JGUFHMAN6 6 ZONE MANIFOLD 1
JGUFHMAN8 8 ZONE MANIFOLD 1
JGUFHMAN10 10 ZONE MANIFOLD 1
JGUFHMAN12 12 ZONE MANIFOLD 1
MANIFOLDS
PART DESCRIPTION PACK
NO.QTY
JGPUMPPACK PUMP PACK 1
PUMP PACK
Hot water is taken from the boiler, mixed to the required
temperature and circulated via the manifold to the
heating circuits, the temperature and volume of water is
constantly altered to maintain the requirements of the
system. Flow temperature can be altered by turning the
hand wheel on the mixing valve unit.
The pack is light and compact so a wall bracket is not
needed and flat face unions make for an easy connection
to the manifold.
PART DESCRIPTION PACK
NO.QTY
JGUFHA(240 v) 240 v CIRCUIT ACTUATOR VALVE 1
ACTUATOR VALVE
PART DESCRIPTION PACK
NO.QTY
JGUFH4ZM MASTER WIRING CENTRE 4 ZONE 1
MASTER WIRING CENTRE
PART DESCRIPTION PACK
NO.QTY
JGUFHTH ROOM THERMOSTAT WITH 1
SET BACK TEMPERATURE REDUCTION MODE
ROOM THERMOSTAT
PART DESCRIPTION SIZE PACK
NO.QTY
15BPEX-50C BARRIER PIPE 15MM X 50M 1
15BPEX-100C BARRIER PIPE 15MM X 100M 1
15BPEX-120C BARRIER PIPE 15MM X 120M 1
15BPEX-150C BARRIER PIPE 15MM X 150M 1
PEX BARRIER PIPE
Supplied with Speedfit Pipe Inserts and Collet Clips.
Connects to a Master Wiring Centre to
give an additional 4 or 6 zones.
PART DESCRIPTION PACK
NO.QTY
JGUFH4ZS WIRING CENTRE SLAVE 4 ZONE 1
JGUFH6ZS WIRING CENTRE SLAVE 6 ZONE 1
WIRING CENTRE SLAVE
A 3 metre long cable connects a non electrical
probe to a
room thermostat.
PART DESCRIPTION PACK
NO. QTY
JGUFHTHKIT WET AREA PROBE + COVER 1
WET AREA PROBE + COVER
Used in conjunction with the Room
Thermostat with set back control or
Digital Room Thermostat, the kit is used
in areas where the use of 240v would be
a problem.
Used to connect the wiring from thermostat, actuators,
boiler and pump and manage the control of the underfloor
heating system.
The Programmable Room Thermostat is a fully programmable
electronic room thermostat which can be set to give each
zone an individual time and temperature control.
PART DESCRIPTION PACK
NO. QTY
JGUFHPRS PROGRAMMABLE ROOM 1
THERMOSTAT
PROGRAMMABLE ROOM THERMOSTAT
If specified, one timer is needed for each manifold in the
system. The timer provides centralised control of the set
back functions for the whole manifold via a digital
programmer. The timer acts as a timed switch to alternate
between ‘daytime’ and ‘Set Back’ time.
PART DESCRIPTION PACK
NO.QTY
JGUFHTIMER-C CENTRALISED SYSTEM TIMER 1
CENTRALISED SYSTEM TIMER
To be used with a Speedfit Set Back Thermostat.
PART DESCRIPTION PACK
NO.QTY
JGUFHTIMER-R REMOTE SYSTEM TIMER 1
REMOTE SYSTEM TIMER
A 4 channel programmer. Ideal for installations where the
system timer needs to be located away from the manifold.
Can also be used, via a Master Wiring Centre, to control
the set back for up to 4 Speedfit Room Thermostats. On a
larger system the Remote System Timer can be used to
replace a number of individual programmers, controlling
say underfloor heating, radiators and hot water.
PART DESCRIPTION PACK
NO.QTY
JGUFHSP400 390mm x 1000mm 1
JGUFHSP250 390mm x 250mm 1
JGUFHSP165 165mm x 1000mm 1
SPREADER PLATES
Spreader Plates are available for timber flooring using either traditional joists or TJI Joists.
Actuators are attached to the individual
heating circuits on the manifold, providing
individual control to a room or zone.
They open or close the flow of water and are controlled
by a thermostat or programmer.
PART DESCRIPTION SIZE PACK
NO.QTY
15BPB-50C BARRIER PIPE 15MM X 50M 1
15BPB-100C BARRIER PIPE 15MM X 100M 1
15BPB-120C BARRIER PIPE 15MM X 120M 1
15BPB-150C BARRIER PIPE 15MM X 150M 1
POLYBUTYLENE BARRIER PIPE
PART DESCRIPTION PACK
NO. QTY
SPUFH1 MIXING VALVE CARTRIDGE KIT 1
SPUFH2 PUMP PACK FLOW TEMP GAUGE 1
SPUFH3 OVER HEAT STAT 1
SPUFH4 MANIFOLD FLOWMETER 1
SPUFH5 MANIFOLD BALANCING VALVE 1
SPUFH6 DUST CAP FOR BALANCING VALVE 1
UNDERFLOOR HEATING SPARE PARTS
PART DESCRIPTION PACK
NO.QTY
JGUFHMANEXT MANIFOLD EXTENSION KIT 1
MANIFOLD EXTENSION KIT
Enables a manifold to be extended
by one or more zones.
Spreader Plates 390 x 1,000mm and 390 x 250mm are
laid across traditional joists and fixed in place using a
hand stapler.
Spreader Plates 165 x 1000mm can be used with
traditional and TJI joists. They are fixed to the underside
of the floor using staples or screws.
Speedfit Pipe is fixed in the grooves of the plates.
When the plates and pipework have been installed,
insulation is placed in the void below the plates to
minimise downward heatloss.
PART DESCRIPTION SIZE PACK
NO.QTY
JGUFHSTAPLE PIPE STAPLES 60mm 300
JGUFHGUN STAPLE GUN -1
PART DESCRIPTION PACK
NO.QTY
JGUFHEDGE 25 METRE ROLL 1
EDGE INSULATION STRIP
Black Staples are barbed to ensure a secure fixing to
the insulation. Easy fixing is carried out by using a
Staple Gun, securing pipe to the insulation with an
easy repeatable action.
Supplied in 25 metre rolls, the edge insulation
strip is placed round the edge of each room to
provide insulation of the heated floor.
PIPE FIXING SYSTEMS
PART DESCRIPTION PACK
NO. QTY
JGUFHRAIL 2 METRE LONG 16
JGUFHPIN RAIL PINS FOR ABOVE 100
PART DESCRIPTION PACK
NO.QTY
JGUFHCLIP FLOOR CLIP 100
JGUFHTOOL FOR EASY FIXING OF FLOOR CLIPS 1
Mounting Rails offer a quick installation of 15mm pipe.
Supplied 2 metres long, the rails are pre scored every
100mm for easy cutting. The rail can be secured to the
insulation using red Rail Pins.
Floor Clips screw easily into insulation, they
are best installed using a Fixing Tool.
Works in conjunction with a Centralised or Remote System Timer
PART PACK
NO. QTY
JGUFHMANELB 1 PAIR
MANIFOLD ELBOW CONNECTOR
A mains operated room thermostat. The temperature is
set manually to ‘Daytime’ temperature and reduced by
4oC to ‘Setback’ temperature by a Centralised or Remote
System Timer. It has a manual override for permanent
‘Daytime’ or permanent ‘Setback’ temperature and can be
used in conjunction with a Wet Area Probe.
PART DESCRIPTION PACK
NO.QTY
JGUFHTHDIG DIGITAL ROOM 1
THERMOSTAT
DIGITAL ROOM THERMOSTAT
Works in conjunction with a Centralised or Remote System Timer
Enables a Pump Pack and
Manifold to be installed at 90º to
each other.
PART DESCRIPTION PACK
NO.QTY
JGUFHTILE Floor Tile 12
1400mm x 800mm
FLOOR PANELS
Supplied in packs of 12, Speedfit Floor Tiles
have an 11mm layer of insulation for support
and additional thermal insulation.
The control unit has integral ball valves to allow for
isolation from the primary heating system, an adjustable
blending valve and a 6 metre head circulation pump. An
anti-vibration mounting bracket ensures silent operation.
Speedfit push in connections make for a fast connection
to pipework.
Speedfit recommend connection to the main central
heating flow and return distribution system, but it is also
possible to connect to the nearest radiator supply pipe.
A full and detailed installation guide is provided with each unit.
The Speedfit Underfloor Heating Control Unit is suitable
for use when:
The boiler serving the existing heating system has
the capacity to take the extra output from 2KW to 3KW
The boiler is compatible with the additional pump
The maximum area to be heated is 30 sq metres
The Control Unit is designed to be used with Speedfit
Barrier Pipe. The amount of pipe needed is determined
not only by the size and shape of the room but by the
resistance of the floor finish to heat transfer.
The table below shows examples of low resistance (tiles)
and high resistance (carpet with underlay) finishes.
Part Coil Size Staples Max Area Temp/Tiles Temp/Carpet Max Output
No. (m) Required (m2) (ºC) (ºC) (KW)
15BPEX-150C 150 240 20 44 58 1.8
15BPEX-120C 120 200 17 44 58 1.5
15BPEX-100C 100 170 14 44 58 1.2
15BPEX-50C 50 100 7 44 58 0.6
COIL SIZE TO AREA
PART DESCRIPTION PACK
NO.QTY
JGROOMPACK SINGLE ROOM CONTROL UNIT 1
SINGLE ROOM CONTROL UNIT
The new Speedfit Underfloor Heating
Control Unit is the ideal way to provide
heating to a conservatory or room
extension, up to 30m2.
The unit is pre-assembled and pre-wired
to allow for a fast and simple installation.
SOLID FLOOR INSTALLATIONS
The screed is an important and integral part of the UFH
system, transferring energy from the pipes to the area to
be heated. The response of this ‘thermal mass’ will depend
on its depth and make up.
The usual depth of screed is 65 - 75mm thick but it is possible
depths can be reduced to assist in improving performance.
SCREEDS
PIPE LAYOUT IN SOLID FLOOR INSTALLATIONS
The shape of the room and the position of the outside
walls and windows will determine the pattern of the pipe
layout. The counterflow pattern is recommended although
other options are shown below.
Single Serpentine Double Serpentine
Triple Serpentine Counterflow
INSTALLATION IS QUICK AND EASY
The floor is cleared
of dust and debris
and insulation is laid
across the area.
Speedfit Pipe is laid
in a
pre-determined
pattern and
fixed in
position with staples.
Fit the Speedfit Manifold
to the wall and connect the
Pump Pack.
Connect the ends of the
pipes to the Manifold.
The system is filled and
pressure tested.
The screed should be laid
whilst the pipe is pressurised.
The underfloor heating
system should not be used
to dry the concrete screed.
25 26
SPEEDFIT SYSTEM COMPONENTS
TIMBER FLOOR INSTALLATIONS
Spreader plates are available
for timber flooring which
uses either traditional
joists
or TJI joists.
Spreader plates 390mm x
1,000mm and 390mm x
250mm are designed for
use with traditional joists
at 400mm centres. They
are laid across the joists
and fixed in place using a
hand stapler. The 15mm
Speedfit Pipe is pushed
into the grooves in the
plate and the floor decking
laid on top.
Insulation can be placed
between joists to the
underside of the plates
either before or after the
plates have been laid.
Spreader plates 165mm x
1000mm can be used
with either traditional or
TJI joists and with the
floor already in place.
They are fixed to the
underside of the floor
using staples or screws.
The Speedfit Pipe is
fixed in to the groove.
When the plates and
pipework have been
installed, the insulation
is placed in the floor
void to minimise
downward heat loss.
PART DESCRIPTION PACK
NO.QTY
JGUFHPACK20 UNDERFLOOR HEATING PACK 1
SINGLE ROOM UNDERFLOOR HEATING PACK
For conservatories or room extensions up to 20m2.
Pack contains: Single Room Control Unit
Programmable Room Thermostat
15mm x 150m coil Polybutylene Pipe
with Pipe Clips and Pipe Inserts
PART DESCRIPTION PACK
NO. QTY
JGUFHPACK30 UNDERFLOOR HEATING PACK 1
SINGLE ROOM UNDERFLOOR HEATING PACK
For conservatories or room extensions up to 30m2.
Pack contains: Single Room Control Unit
Programmable Room Thermostat
2 x 15mm x 100m coils of Polybutylene Pipe
• 300 x 15mm Pipe Clips
• 8 x 15mm Pipe Inserts
• 2 x 15mm Speedfit Equal Tees
• 2 x 15mm Speedfit Swivel Elbows
UNDERGROUND FITTINGS
Speedfit underground fittings for metric size polyethylene
cold water service pipe have been designed for
connection of:
1. Blue MDPE pipes to BS 6572 - used for underground
service pipes for potable water.
2. Black MDPE pipes to BS6730 - used for conveyance
of potable water above ground or for industrial
services above or below ground.
3. Pipe to ISO 161/1, ISO 3607 and DIN 16893.
Making the connection could not be easier. All you need is
the pipe, the fitting and a pair of hands. The range is
designed to provide a long service life and includes adaptors
for screwed pipe, copper and imperial sized LDPE.
Easy to use in confined spaces, no tools required.
Fast installation with resulting cost savings.
Lightweight and slimline.
Ready for immediate installation, no dismantling.
No adjustments required after fitting.
Adaptors for screwed pipe, copper and imperial LDPE.
Maintenance free.
Durable with high resistance to impact.
Patented collet ensures high resistance to pull out.
Lead free and non toxic.
Will not support biological growth.
A reliable and trouble free leakproof connection.
Cut pipe square using pipe cutters, remove burrs and
sharp edges. Always use a pipe insert.
Pipe insert
The fitting is supplied ready
for installation and requires
no adjustment. Push the
pipe into the fitting.
Push pipes into fitting
Collet
ʻOʼ ring Collet Cover
Push the pipe up to the
pipe stop. The collet has
teeth that grip the pipe
whilst the ‘O’ ring provides
a permanent leak proof
seal.
Ensure that the system is
depressurised. Release and
pull back collet cover.
Push in collet square against
the face of fitting.
With the collet held in this position, the pipe can be withdrawn.
We recommend the replacement of the ‘O’ ring and collet
before making a new connection.
Remove collet cover, pull
out metric size collet and
‘O’ ring. Keep with metric
pipe support liner for future use.
Carefully push imperial size
‘O’ ring and collet into
position, ensuring seal is
clean before insertion.
Replace the snap-fit collet
cover and, having inserted
the imperial pipe support,
connect the pipe as
shown above.
Using the Inch Change Kit shown on page 28.
PART NO.SIZE MM
JG401B 20
JG402B 25
Cold water only
PART NO.SIZE MM
JG501B 25 x 20
Cold water only
PART NO.SIZE
JG101B 20mm x 1/2” BSP
JG102B 25mm x 3/4” BSP
Cold water only
PART NO.SIZE
JG4501B 20mm x 1/2” BSP
JG4502B 25mm x 3/4” BSP
Cold water only
PRODUCT RANGE
PART NO.SIZE MM
JG301B 20
JG302B 25
Cold water only
PART NO.SIZE MM
JG801E 20
JG802E 25
Cold water only
PART NO.PIPE STEM
OD OD
JG222025B 20mm 25mm
JG222525B 25mm 25mm
PART NO.SIZE MM
JG601B 20 x 15
JG603B 25 x 15
JG602B 25 x 22
Cold water only
Suitable for Tables X & Y Copper
Used to connect PE Pipe to
copper or Speedfit Plumbing Pipe
PART NO.SIZE MM
UTS147 - DB 20
UTS197 - DB 25
SPARE PARTS
PART NO.SIZE MM
20 UPC 20
25 UPC 25
PART NO.SIZE MM
20 UOR 20
25 UOR 25
PART NO.SIZE MM
JG201B 20
JG202B 25
Cold water only
PART NO.SIZE MM
JGK01E 1/2”
JGK02E 3/4”
Cold water only
To convert metric size fittings for
use with imperial size LDPE to
BS1972 Class C or Class D
APPLICATIONS
INSTALLATION BENEFITS
PERFORMANCE BENEFITS
MAKING A GOOD CONNECTION
TO DISCONNECT
CONNECTING TO IMPERIAL SIZE LDPE
EQUAL STRAIGHT CONNECTOR
REDUCING STRAIGHT CONNECTOR
MALE ADAPTOR
FEMALE ADAPTOR
PLUGS
EQUAL ELBOW
STEM ELBOW
EQUAL TEE
PE-COPPER COUPLER
PIPE INSERT
COLLETS
‘O’ RING
INCH CHANGE KIT
27 28
Fittings and pipe should be kept clean and undamaged before use.
Sizes. 10mm to 28mm diameter.
Pipes. Speedfit fittings can be used with:
Copper pipe to BS EN 1057
Speedfit Barrier Pipe to BS7291.
Speedfit fittings cannot be used on stainless steel pipe.
Standards. Speedfit products are designed and manufactured
under
a fully integrated system assessed by B.S.I. to BS EN ISO9001.
They are
approved by the WRAS and BBA. Speedfit PEM, PSE and SFM
Fittings and Speedfit Barrier Pipe are Kitemarked to BS7291 Parts 1, 2
and 3, Class S. (Licence No. KM39767)
Applications.
Mains fed and indirect cold water systems
Vented and unvented hot water systems
Vented and sealed central heating systems
Do not use for Gas, fuel oil or compressed air applications.
Working temperatures and pressures
Application Usual working Maximum working Maximum working
temperature, ºC temperature, ºC pressure, bar
Cold Water 20 20 12
(indirect and direct mains)
Central Heating 82 105, short term 3
malfunction at 114
Hot Water 65 95 6
(including unvented cylinders)
Burst Pressure (fittings). With copper or plastic pipe at 20°C: Speedfit
fittings used with copper or Speedfit Barrier Pipe will withstand pressures
well in excess of normal service conditions.
High temperatures. Can withstand 114°C intermittently for short periods.
The Speedfit system should not be used on an uncontrolled heat source.
Insulation. Should comply with BS6700 and BS5422, as for copper.
Minimum bend radii (PEX)
Pipe diameter
10mm 15mm 22mm 28mm
Min radius with clips
100mm 175mm 225mm 300mm
Min radius with cold forming bend
30mm 75mm 110mm -
Clip spacing (in mm).
For surface mounted pipes
Pipe Diameter Clip Spacing
Horizontal Run Vertical Run
10 - 15mm 300mm 500mm
22mm 500mm 800mm
28mm 800mm 1,000mm
Where pipe is concealed, clipping may only be required where necessary.
Expansion (PEX pipe). 1% on length between 20°C and 82°C.
Flow rates. Comparable with metal systems.
Cleaners, inhibitors and descalents. For advice on the replenishment of
additives such as corrosion inhibitors, the following manufacturers should
be contacted: Fernox Manufacturing Limited on 01799 550811 or Sentinel,
BetzDearborn Limited on 0151 420 9595.
Paint and Chemicals. Use only water or oil based paint. Collet covers
prevent paint ingress into fittings. DO NOT ALLOW CONTACT WITH
oil based jointing compounds, cellulose based paints, paint thinners, paint
strippers, solder flux, acid based descalents or aggressive cleaning products.
Solder Flux. No fluxes of any types should come into contact with
JG Speedfit Pipe and Fittings. If fluxes are to be used in an environment
where Speedfit is installed, then (1) extreme care should be taken to ensure
that no such contact takes place and (2) JG recommend installers only use
fluxes tested and approved in writing in advance by JG. At the date of this
publication, the only such approved flux is Fernox Flux.
TECHNICAL CHECKLIST -
PLUMBING AND HEATING FITTINGS
29 30
Applications. Speedfit Underground Fittings are designed to connect
MDPE pipes (MRS-PE80) used above or below ground, to convey
potable water from distribution mains to individual properties.
Sizes. 20mm and 25mm with adaptors for:-
- Copper to BS2871 Part 1 / BS EN1057. Table X and Table Y.
- Screwed pipe.
- LDPE (to BS1972 Class C and Class D) in 1/2” and 3/4” inch sizes.
Pipes. Speedfit Underground Fittings can be used with:-
- Blue MDPE pipe to BS6572.
- Black MDPE pipe to BS6730.
- Pipes conforming to ISO161/1, ISO3607 and DIN16893.
Working Temperatures and Pressures. Maximum working pressure
12 Bar @ 20˚C.
Standards. Speedfit Underground Fittings are approved by the
Water Regulations Advisory Scheme.
Performance. The fittings are manufactured from tough plastic
material well able to meet the stringent requirements of the water
industry. They have been approved by the WRAS and, as such,
have passed the ʻpull out testʼ where a force shown below is applied
to a connection between MDPE pipes and a fitting for 5 minutes
without the connection failing.
Size
Test Force 20mm 25mm
Newtons 1900 2500
lbs 427 562
DO NOT USE FOR Gas, fuel oil or compressed air applications
or hot water.
Chemical Effects. For below ground applications the fittings require
no additional preparations - coating etc. When used above ground,
avoid contact with aggressive chemical compounds. Protect from frost
where necessary. In the United Kingdom, potable water does not
contain high levels of chemicals (eg chlorine etc) that would adversely
affect Speedfit Underground Fittings.
Exposure to sunlight. Permanent exposure to direct sunlight will
necessitate lagging the fittings.
Pipe Inserts. Pipe inserts must be used and fully inserted on all
connections to MDPE or LDPE pipe.
System Testing. Pressure test to 1.5 times working pressure for 10
minutes before connecting to the mains supply. It is recommended
that all pipe and fitting installations are pressure tested after
installation before handing over to the final user
Maximum Torque Figures. The maximum torque figures for BSP
and BSPT threads used on Speedfit products are as follows:-
Size Maximum Torque
1/2 3.0 Nm
3/4 4.0 Nm
It is recommended that all installations are checked prior to use to
determine that a seal has been made.
The maximum torque figures quoted for use with Speedfit fittings are
dependent on the mating thread conforming to the relevant British
International thread standards.
TECHNICAL CHECKLIST -
UNDERGROUND FITTINGS
Applications. Underfloor Heating Installations in solid or timber floors.
Pipes. 15mm JG Speedfit Barrier Pipe to BS 7291, Parts 1, 2 and 3 Class S.
DO NOT USE Speedfit UFH Products for Gas, fuel oil or compressed
air applications.
Floor Insulation. Should be a suitable material and thickness to comply
with current regulations.
Minimum Bending Radii. For Speedfit B-PEX Pipe is 175mm.
Expansion (PEX - Pipe). 1% on length between 20˚C and 82˚C.
Cleaners, Inhibitors and Descalents. For advice on the replenishment of
additives such as corrosion inhibitors, the following manufacturers
should be contacted Fernox Manufacturing Limited on 01799 550811 or
Sentinel, BetzDearborn Limited on 0151420 9595.
Paint and Chemicals. Only use water or oil based paint. DO NOT ALLOW
CONTACT WITH cellulose based paints, paint thinners or strippers, solder
flux or acid based descalents or aggressive household cleaning products.
Exposure to sunlight. Speedfit products, when used indoors, are not
affected by sunlight. When used out doors protect from ultra violet light
by lagging or painting.
Pipe Inserts. Must be used on all installations when using plastic pipe and
should be fully inserted.
Electrical Components. Electrical products in the Speedfit Underfloor Heating
Systems are designed only to be used in U.K. Electrical Supply situations.
Electrical Continuity. If Speedfit is used in an existing metal system which
may have been used for earthing, electrical continuity should be reinstated.
Collet Clips. White and Grey collet clips are used with standard fittings to
prevent accidental pipe disconnection. Red or blue clips provide colour
coding of pipe. Red and blue clips should not be used to prevent accidental
release of pipe.
Pre-Screed System Testing. To ensure the pipework has been installed
correctly and prior to the screed being laid, it is essential that the system
is checked and hydraulically wet tested.
Testing should be carried out at 2 bar for 10 minutes and 10 bar for
10 minutes.
This testing, combined with other relevant checks, should reveal installation
problems and is regarded as good plumbing practice.
Pressurisation During Screed Laying & Curing. In accordance with
BS1264-4, the system should be left under pressure at a minimum of 6 bar for
the duration of the laying and curing of the screed.
Under NO circumstances should the UFH System be used to quicken
the screed drying process.
System Flushing. As is usual practice for any plumbing installation,
flushing of the system prior to the use of JG Speedfit is recommended to
remove any contaminants/chemical residue from elsewhere in the system.
Vermin. Speedfit products should not be used in vermin infested areas.
Frost Protection. During the installation process it is important that pipe
containing water be protected from frost.
TECHNICAL CHECKLIST -
UNDERFLOOR HEATING
Chlorine. Speedfit is not suitable for use in systems where the water
contains high levels of chlorine. e.g. swimming pools, fountains etc.
Exposure to sunlight. Speedfit products, when used indoors, are not
affected by sunlight. When used outdoors protect from ultra violet light
by lagging or painting.
Pipe clips.
Pipe clips should not be fitted any closer than 60mm from the
end of the fitting. Pipe should be adequately supported by pipe clips to
prevent undue stress (side load) on fittings.
Pipe inserts. Must be used on all installations when using plastic pipe
and should be fully inserted. Only use a Speedfit Insert with Speedfit Pipe.
Metal Joists.
When ʻcablingʼ plastic pipe through metal joists ensure rubber
grommets are in place to prevent damage to pipe. Use of collet covers or
collet clips on fittings recommended.
Connection to boilers. A minimum 1000mm run of copper pipe must be
i
nstalled between the boiler and the Speedfit system, as per BS5955: Part 8.
Connection to copper pipe. 450mm is the minimum distance to make
a solder connection on copper pipe inserted into a Speedfit Fitting. Ensure
that any residual flux solder does not come into contact with the fitting.
Concrete and masonry. Speedfit pipe and fittings can be laid in concrete
and masonry providing they are installed in conduit pipe with access boxes
for the fittings. This is to enable the pipe to expand and provide accessibility
for both pipe and fittings. As stated in Water Regulation Scheme 2.7 and BS
8000 : Part 15, fittings and pipe should be removable for possible replacement.
Insulation is also recommended to protect against heat loss and the effects
of frost.
Electrical continuity. If Speedfit is used in an existing metal system which
may have been used for earthing, electrical continuity should be reinstated.
Valves and taps. Plastic 15mm and 22mm valves and taps available from
JG Speedfit Ltd are not suitable for central heating installations.
Collet Covers. Collet covers provide added security against pipe
disconnection, e.g. the fittings coming into contact with rigid surfaces
and behind dry-lining walls. They are offered in white as standard and
in red or blue to provide colour coding of pipe.
Collet Clips. Grey collet clips are used with standard fittings to prevent
accidental pipe disconnection. Red or blue clips provide colour coding
of pipe. Red and blue clips should not be used to prevent accidental
release of pipe.
System testing. To ensure the pipework and fittings have been installed
correctly, whether it be on a new or extended system, it is essential that the
system is checked and hydraulically wet tested. Testing should be at 2 bar
for 10 minutes and 10 bar for 10 minutes. This testing, combined with other
relevant checks, should reveal installation problems and is regarded as good
plumbing practice. However, system testing should not be regarded as a
substitute for correct installation (see also “Making a Good Connection”).
System flushing.
As is usual practice for any plumbing installation, flushing
of the system prior to the use of Speedfit is recommended to remove any
contaminants/ chemical residue from elsewhere in the system.
British Gas Service has accepted the John Guest Speedfit fittings as being
suitable for open vented and sealed central heating systems and as eligible
for acceptance onto its service contracts.
Vermin.
Speedfit products will need special protection in vermin infested areas.
Maximum Torque figures (BSP & BSPT).
Plastic threads are not generally as
strong as brass threads. Customers and end users should be aware of this
when choosing products for their applications. Overtightening of plastic threads
will cause undue stress and eventual cracking and leakage. The maximum
torque figures for BSP and BSPT
threads used on Speedfit plumbing products
in mating threads conforming to the relevant BS or International thread
standards are shown below.
Threads Size Maximum Torque
Plastic 1/2” 3.0 Nm
3/4” 4.0 Nm
Brass 1/2” 4.0 Nm
3/4” 5.0 Nm
It is recommended that all installations are checked prior to use to determine
that seal has been made.
Side Loads.
Fittings should not be subject to excessive side loads and they
should not be used as support brackets. Tubing and fittings should be adequately
supported to prevent excessive side loading.

Navigation menu