KROHNE BM702 Part 90.103 Fluid level sensor User Manual Report

Krohne America Inc Part 90.103 Fluid level sensor Report

Contents

Test report

Download: KROHNE BM702 Part 90.103 Fluid level sensor User Manual Report
Mirror Download [FCC.gov]KROHNE BM702 Part 90.103 Fluid level sensor User Manual Report
Document ID120814
Application IDptO2Cc5cIvxb1ssxT2eG6w==
Document DescriptionTest report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize13.03kB (162845 bits)
Date Submitted2000-10-12 00:00:00
Date Available2000-10-11 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat PDFWriter 3.02 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleReport.PDF
Document CreatorMicrosoft Word
Document Author: Unknown

MEASUREMENT/TECHNICAL REPORT
Company: Krohne America, Inc.
Model: BM702
FCC ID: JH5BM702
Description: This is a report to support a request for a type acceptance.
Equipment Type: Radiolocation device
Report prepared for:
Krohne America, Inc.
7 Dearborn Road
Peabody, MA 01960
Phone: 978-535-6060
Fax:
978-535-1720
Report prepared by:
Chad A. Bell
Curtis-Straus LLC
527 Great Road
Littleton, MA 01460 USA
Phone: 978-486-8880
FAX:
978-486-8828
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Table of Contents
LETTER OF AGENCY.................................................................................................................................................. 3
INTRODUCTION .......................................................................................................................................................... 4
Product Description................................................................................................................................................. 5
Related Submittal(s) Grants..................................................................................................................................... 5
Test Methodology..................................................................................................................................................... 6
Test Equipment Used ............................................................................................................................................... 9
Operating Frequency ............................................................................................................................................. 11
Electric Field Strength Radiation Measurements .................................................................................................. 11
Frequency Stability ................................................................................................................................................ 13
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 2 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Letter of Agency
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 3 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Introduction
This report is an application for Certification of a Transmitter operating pursuant to Part 90 of the
FCC Rules, Code of Federal Regulations 47. The model number covered by this report is BM702.
This report is designed to demonstrate the compliance of this device with the requirements
outlined in Part 90 of CFR 47 using the methods outlined in Part 2 of CFR 47. The current
revision date, October 1,1998, of each Part has been used for technical requirements.
The confidential information and descriptions included in this application are detailed descriptions
of the products, block diagrams, component specifications, and schematic diagrams. We hereby
respectfully request under the provision of section 0.457d of the code that the documents listed
below be held confidential.
Technical Descriptions and Block Diagrams
Schematics
Bill of Materials
Krohne America, Inc. is requesting that the Technical Descriptions, Block Diagrams, Schematics
and Bill of Materials be kept confidential in the FCC application because of the proprietary design
developed by Krohne America, Inc. that is unique to the industry.
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 4 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Product Description
The BM 702 level gauge is designed solely for measuring the level, distance, volume and
reflection of liquids, pastes, slurries, particulate materials and solids. Five different antennas are
available for use with the unit depending on the application. There are four horn antennas and
one Wave-Stick antenna. The Wave-Stack antenna has several different part numbers which
correspond to the different lengths of waveguide that lead to the radiating potion of the WaveStick. We tested the 6in Wave-Stick.
Unit Tested
Model Number: BM702
Serial Number: 0/311883.001
Antennas:
3in horn
2116340100
4in horn
2113010100
6in horn
2113000100
8in horn
2112540100
Wave-Stick 3159860600
Related Submittal(s) Grants
There are no other approvals required for this device.
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 5 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Test Methodology
Radiated emission testing was performed according to the procedures in ANSI C63.4 (1992).
Radiated testing was performed at an antenna to EUT distance of 3 meters below 1 GHz, and at
a distance of 3 or 1 meter(s) above 1 GHz. The actual test distance used is noted in the test data
sheets. The device’s performance was investigated to 40GHz. The EUT was powered by a DC
power supply for all tests. All other performance tests were made in accordance with the
procedures outlined in Part 90 of CFR 47.
Each of the antennas was investigated at the fundamental frequency to determine which was the
most efficient radiator – this was the 8in horn antenna. Using the 8in horn antenna, harmonics
and spurious emissions were checked from 7 – 40GHz.
Test Facility
Curtis-Straus LLC
All testing for the range 30–40000MHz was performed at Curtis-Straus (A2LA Certificate Number:
1627-01). The open area test site used to collect the radiated data is located at 527 Great Road,
Littleton, MA 01460. Site “M” was used.
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 6 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 7 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Equivalent Radiated Power
Conducted measurements of the transmitter output were not possible, since the horn antenna is
permanently affixed. Therefore field strength measurements with a horn antenna were done
instead. The following is the calculation of the limit in field strength based on the limit in power.
ERP = Equivalent Radiated Power
PD = Power Density
V = Volts
Fundamental Maximum Measured Output =117.7dBµV/m = 0.767V/m @ 1m
PD = (V/m)^2/(resistance of free space [Ω])
PD = 0.7672/377
PD = 0.00156W/m2
ERP = 4πPD*R2
ERP = 4π(0.00156)*12
ERP = 19.6mW = 0.0196W = Pfund
Emissions 250% or more outside the fundamental should be attenuated by at least:
43dB + 10 log Pfund
25.9dB
To calculate the limit of the harmonics:
E = 5.5/(distance) x SQRT(Ptot)
- Formula for E-field from isotropic antenna
Ptot = 19.6mW – 25.9dB = 12.92dBm – 25.9dB = -13dBm = -43dBW
Ptot = 0.00005W
E1m = (5.5/1) * SQRT (0.00005)
E1m = 0.039V/m = -28.1dBV/m = 91.8dBµV/m
E1m = 91.8 dBµ
µV/m
Therefore the limit in field strength at 250% outside of the authorized bandwidth is as follows:
E1m = 91.8 dBµ
µV/m
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 8 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Test Equipment Used
SPECTRUM ANALYZERS
Analyzer
WHITE
9kHz-22GHz
GREEN
9kHz-26.5GHz
BLACK
9kHz-12.8GHz
ORANGE
9kHz-26.5GHz
Model No.
Company
Serial No.
Calibration Due
8593E
HP
3547U01252
24-APR-2001
8593E
HP
3829A03618
04-OCT-2000
8596E
HP
3710A00944
28-JUN-2001
E4407B
HP
US39440975
05-MAY-2001
LISNS
LISN
YELLOW-BLACK
9kHz-30MHz
Model No.
Company
Serial No.
Calibration Due
8012-50-R-24-BNC
Solar
984735
26-OCT-2000
OPEN AREA TEST SITES (OATS)
Site
“F”
Florida
“M”
Maine
FCC Code
IC Code
VCCI Code
Calibration Due
93448
IC 2762-F
R-468/ C-480
28-JUN-2001
93448
IC 2762-M
R-904/ C-480
22-MAY-2001
Model No.
Company
Serial No.
Calibration Due
CBL6112B
Chase
2412
23-JUN-2001
3115
EMCO
9703-5148
31-MAY-2001
3160-09
EMCO
9610-1068
10-MAY-2001
ANTENNAS
Antenna
GREEN-BLACK
Bilog: 30MHz-2GHz
BLACK
Horn: 1-18GHz
WHITE
Std Gain Horn: 18-26.5GHz
HARMONIC MIXER
Mixer
Model No.
Company
Serial No.
Calibration Due
HARMONIC MIXER
11970A
HP
2332A00900
24-MAY-2001
26.5-40 GHZ
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 9 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
PREAMPLIFIERS
Preamplifier
WHITE
1-20GHz
BLACK
0.01-2000MHz
YELLOW-BLACK
1-20GHZ
YELLOW
18-26.5GHz
Model No.
Company
Serial No.
Calibration Due
SMC-12A
MITEQ
426643
09-OCT-2001
n/a
01-MAR-2001
ZFL-1000-LN
MiniCircuits/
C-S
SMC-12A
MITEQ
535055
17-OCT-2000
AFS4-1800265060-8P-4
MITEQ
467559
28-AUG-2001
Model No.
Company
Serial No.
Calibration Due
TH300
Dickson
9044101
27-MAR-2001
BA928
Oregon
Scientific
C3166-1
21-AUG-2001
METEOROLOGICAL METERS
Meter
TEMPERATURE
/HUMIDITY GAUGE
ATMOSPHERIC
PRESSURE GAUGE
TRACEABLE CLOCKS
Clock
Model No.
Company
Serial No.
Calibration Due
5003
5003
Control
Company
99026940
16-NOV-2000
Unless otherwise noted the calibration interval is one year. All equipment is calibrated using standards
traceable to NIST or other nationally recognized calibration standard.
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 10 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Measurement Results
Operating Frequency
This device operates at spread source from 8.8-9.8 GHz.
Electric Field Strength Radiation Measurements
Radiated Emissions Table
Curtis- Straus LLC
Date: 03-Jul-00
Engineer: David Heald
Company: Krohne America
EUT Desc: BM702
Table: 1
Work Order: A0897
Frequency Range: 30-1000 MHz
Measurement Distance: 3 m
Notes: EUT not mounted in the tank
Antenna
Polarization
(H / V)
Frequency
(MHz)
Table Result:
CISPR Class B
FCC Class B
Preamp
Antenna
Cable
Adjusted
Reading
(dBµV)
Factor
(dB)
Factor
(dB/m)
Factor
(dB)
Reading
(dBµV/m)
Limit
(dBµV/m)
Margin
(dB)
Result
(Pass/Fail)
Limit
(dBµV/m)
Margin
(dB)
Result
(Pass/Fail)
37.2
41.1
38.0
34.8
38.4
46.4
49.6
46.0
48.0
45.1
39.2
33.4
33.6
34.4
31.9
--22.4
22.4
22.3
22.3
22.3
22.3
22.3
22.3
22.4
22.4
22.4
22.5
22.5
22.5
22.5
--8.9
13.0
13.2
12.6
11.4
10.7
10.6
10.4
10.4
10.4
12.2
13.3
13.7
14.4
14.7
--0.8
1.0
1.1
1.1
1.2
1.3
1.3
1.3
1.4
1.4
1.7
1.8
1.9
2.0
2.0
--24.5
32.7
30.0
26.2
28.7
36.1
39.2
35.4
37.4
34.5
30.7
26.0
26.7
28.3
26.1
--40.5
40.5
40.5
40.5
40.5
40.5
40.5
40.5
40.5
40.5
40.5
47.5
47.5
47.5
47.5
---16.0
-7.8
-10.5
-14.3
-11.8
-4.4
-1.3
-5.1
-3.1
-6.0
-9.8
-21.5
-20.8
-19.2
-21.4
--Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
--40.0
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
43.5
46.0
46.0
46.0
46.0
46.0
---15.5
-10.8
-13.5
-17.3
-14.8
-7.4
-4.3
-8.1
-6.1
-9.0
-15.3
-20.0
-19.3
-17.7
-19.9
--Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
by
EUT sitting on the table
86.0
122.0
126.0
134.0
154.0
166.0
170.0
174.0
186.0
190.0
230.0
254.0
270.0
294.0
306.0
Test Site: "M"
EUT Max Freq: 9.5 GHz
Pre-Amp: Black
-1.3 dB
Worst Freq:
Cable: 65 ft RG8A/U
Analyzer: Green
Radiated Emissions Table
Date: 11-Oct-00
Engineer: Stacey C. Costa
Curtis-Straus LLC
Company: Krohne America
EUT Desc: BM702
Table 2
Work Order: A0897
Frequency Range: 8.75-10GHz
Notes: Comparison at fundamental to determine highest gain antenna
Antenna
170.0 MHz
Antenna: Grn-Blk
Measurement Distance: 1 m
---
---
Preamp
Antenna
Cable
Adjusted
Polarization
Frequency
Reading
Factor
Factor
Factor
Reading
Limit
Margin
Result
Limit
Margin
Result
(H / V)
(MHz)
(dBµV)
(dB)
(dB/m)
(dB)
(dBµV/m)
(dBµV/m)
(dB)
(Pass/Fail)
(dBµV/m)
(dB)
(Pass/Fail)
9322.0
87.1
9300.0
89.3
9319.0
91.9
9313.0
92.8
--18.0
--18.0
--18.0
--18.0
--18.0
--40.7
--40.7
--40.7
--40.7
--40.7
--2.2
--2.2
--2.2
--2.2
--2.2
--112.0
--114.2
--116.8
--117.7
--115.7
---------------------
---------------------
---------------------
---------------------
---------------------
---------------------
3 Inch
4 Inch
6 Inch
8 Inch
Wavestick
9322.0
Test Site: "F"
90.8
Pre-Amp: White
Cable: 3m Sucoflex
Analyzer: Orange
Antenna: Black Horn
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 11 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Radiated Emissions Table
Date: 11-Oct-00
Engineer: Stacey C. Costa
Curtis-Straus LLC
Company: Krohne America
EUT Desc: BM702
Table 3
Work Order: A0897
Frequency Range: 1-18GHz
Measurement Distance: 1 m
Notes: 8in horn antenna
Antenna
---
FCC Part 90
Preamp
Antenna
Cable
Adjusted
Polarization
(H / V)
Frequency
(MHz)
Reading
(dBµV)
Factor
(dB)
Factor
(dB/m)
Factor
(dB)
Reading
(dBµV/m)
Limit
(dBµV/m)
Margin
(dB)
Result
(Pass/Fail)
Limit
(dBµV/m)
Margin
(dB)
Result
(Pass/Fail)
noise floor
9313.0
18000.0
92.8
40.4
18.0
20.4
40.7
45.2
2.2
3.1
117.7
68.3
-----
-----
-----
--91.8
---23.5
--Pass
Test Site: "F"
Pre-Amp: White
Cable: 3m Sucoflex
Analyzer: Orange
Antenna: Black Horn
Radiated Emissions Table
Curtis-Straus LLC
Date: 11-Oct-00
Engineer: Stacey C. Costa
Company: Krohne America
EUT Desc: BM702
Table 4
Work Order: EA0897
Frequency Range: 18-40GHz
Measurement Distance: 1 m
Notes: 8in horn antenna
Antenna
---
FCC Part 90
Preamp
Correction
Antenna
IF Cable
Adjusted
Polarization
(H / V)
Frequency
(MHz)
Reading
(dBµV)
Factor
(dB)
Loss
(dB)
Factor
(dB/m)
Factor
(dB)
Reading
(dBµV/m)
Limit
(dBµV/m)
Margin
(dB)
Result
(Pass/Fail)
Limit
(dBµV/m)
Margin
(dB)
Result
(Pass/Fail)
noise floor
noise floor
27000.0
36000.0
15.4
13.8
22.5
22.5
23.0
23.2
38.9
41.4
0.3
0.3
55.1
56.2
-----
-----
-----
91.80
91.80
-36.7
-35.7
Pass
Pass
Test Site: "F"
Pre-Amp: Black
Cable: Sucoflex
Analyzer: Orange
Curtis-Straus LLC
Conducted Emissions Chart
Date: 26-Jul-00
Engineer: Chad A. Bell
Antenna: 26.5-40Ghz with mixer
Company: Krohne America
EUT Desc: BM702
Notes: Measured on the AC side of the DC supply
Range: 0.45 - 30.0 MHz
LISN(s): Yellow-Black
Quasi-Peak
FCC Class B
Frequency
L1
L2
Reading
Limit
Result
(MHz)
(dBµV)
(dBµV)
(dBµV)
(dBµV)
(Pass/Fail)
0.45
25.0
25.0
25.0
48.0
Pass
0.55
28.3
28.2
28.3
48.0
Pass
0.65
25.8
26.0
26.0
48.0
Pass
1.56
26.1
26.0
26.1
48.0
Pass
3.63
25.8
26.0
26.0
48.0
Pass
20.30
26.0
26.0
26.0
48.0
Pass
Table No: 5
Work Order: EA0897
L1
(dBµV)
Average
L2
(dBµV)
Reading
(dBµV)
25.0
28.3
26.0
26.1
26.0
26.0
Spectrum Analyzer: White
FCC Class B
Overall
Limit
Result
Margin
(dBµV)
(Pass/Fail)
(dB)
48.0
Pass
-23.0
48.0
Pass
-19.7
48.0
Pass
-22.0
48.0
Pass
-21.9
48.0
Pass
-22.0
48.0
Pass
-22.0
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 12 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Frequency Stability
FREQUENCY STABILITY DATA SHEET
Work Order: A0897
Date(s): 11-Aug-00
Engineer: Mike Buchholz and Matt Deeter
EUT: BM702
Company: Krohne America Inc.
Modifications since start date:
none
Modifications this test:
none
Test Equipment Used:
Analyzer: Black
B-M-A Inc Environmental Chamber
Atmospheric Conditions:
Temp: 24.0°C
Humidity: 30.60%
Temperature( oC)
-30
-20
-10
10
20
30
40
55
Model SGTH-315
Pressure: 1006mbar
fL (GHz) % Deviation fH (GHz) % Deviation
8.861
8.838
8.841
8.844
8.844
8.848
8.867
8.874
8.874
0.147
0.113
0.079
0.045
0.045
0.000
0.215
0.294
0.294
9.715
9.712
9.719
9.722
9.725
9.725
9.738
9.745
9.754
0.103
0.134
0.062
0.031
0.000
0.000
0.134
0.206
0.298
Stability with 85% and 115% Input Voltage at 20oC
24V
8.870
0.000
9.751
20.4V
8.870
0.000
9.751
27.6V
8.870
0.000
9.748
0.000
0.000
0.031
*The fundamental is a spread frequency, swept from fL to fH
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 13 of 14
FCC Application for Krohne America, Inc. •FCC ID: JH5BM702 • Report No. EA0897-1
______________________________________________________________________________ 11-Oct-00
Emissions Plots:
Fundamental
_____________________________________________________________
Curtis-Straus LLC • 527 Great Road • Littleton, MA • TEL (978) 486-8880 • FAX (978) 486-8828
Page 14 of 14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 14
Creator                         : Microsoft Word
Create Date                     : Wednesday, October 11, 2000 4:03:07 PM
Title                           : Report.PDF
Author                          : Unknown
Producer                        : Acrobat PDFWriter 3.02 for Windows
Subject                         : 
EXIF Metadata provided by EXIF.tools