EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 1 of 10 P/N: 01553-001 Rev. D
This installation guide provides, basic installation information, drawings, and controller setup instructions to use when
installing the EntraGuard Platinum Telephone Entry controller. The EntraGuard Platinum controller may be used alone or
may be connected to an access control network using PXL-500 family controllers. For instructions on how to install a
postal lock, see the EntraGuard Platinum Postal Lock Installation Application Note (p/n 01964-001).
NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the
hardware installation.
1.0 Drawings
1.1 EntraGuard Platinum Enclosure
Figure 1: The EntraGuard Platinum Telephone Entry Controller
Wiring diagrams are provided for the new style Platinum controller PCB (p/n 05735-001, see Figure 3 on page 3) and old
style Platinum controller PCB (p/n 05728-001, see Figure 4 on page 4).
NOTE: Power down the unit before making or removing any connections. Failure to do so will damage the controller.
NOTE: Please refer to the Compatibility_Guide_Series_3_and_4.pdf document (p/n 01876-001) for Doors software/
Entraguard firmware compatibility.
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 2 of 10 P/N: 01553-001 Rev. D
1.2 Enclosure Mounting Diagram
Figure 2: Entraguard Platinum Mounting Diagram
0.00
0.552
1.553
9.686
10.235
0.00
1.001
6.892
10.888
11.223
12.48
13.808
all units in inches
0.256 dia
1.374 dia
0.386 dia
0.258 dia
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 3 of 10 P/N: 01553-001 Rev. D
1.3 New Style Platinum Controller
Figure 3: New Style Entraguard Platinum Controller – p/n 05735-001
Alarm
Relay
Lock
Relay
GP
Output
Relay 2
GP
Output
Relay 1
6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1
3
2
1
6 5 4 3 2 1
123
2 1
485
U18
U2
Battery
D4
D5
D6
D20 D18
D30
D29
D25
D32
SW1
R75
J3
J1
J6
J8
Internal
Modem
J11
J16 - Postal Lock Connection
JP1
JP2
J19J20
LED Backlight
Connection
J13
U5
J9 TB15
TB1
TB2
TB3TB4 TB10
TB12
1) Door Switch - NC
2) Ground
3) Request to Exit - NO
4) - not available-
5) Ground
6) Global Unlock - NO
or Auxiliary RTE - NO
TB4 - Inputs
1) Lock - NO
2) Lock - Common
3) Lock - NC
4) Alarm - NO
5) Alarm - Common
6) Alarm - NC
TB3 - Lock &
Alarm Relays
1) GP1 - NO
2) GP1 - Common
3) GP1 - NC
4) GP2 - NO
5) GP2 - Common
6) GP2 - NC
TB10- General
Purpose Outputs
1) Tx/Rx -
2) Tx/Rx +
3) Shield
TB1 - RS-485
Network
1) +12 VDC
2) Negative (Ground)
3) Earth Ground
TB2 - 12 VDC Power
TB15 - Wired Telephone Connection
1) TIP2) Ring
J9 - Standard Phone Jack Connection
U39
J10
LAN
Communication
Jumpers
Modem Module
RxD
DTR
TxD
TB12 - RS-232 Serial Port Connection
Pin 3 (RxD) to Pin 1 (TxD)
Pin 2 (TxD) to Pin 2 (RxD)
Pin 7 (RTS) to Pin 4 (RTS)
Pin 4 (DTR) to Pin 5 (DTR)
Pin 5 (Gnd) to Pin 6 (Gnd)
Modem Side DB-9M
(back side of connector)
6
5
4
3
2
1
TB12 - Modem Connection
2345
7
1
2
3
4
5
6
Pin 2 (RxD) to Pin 1 (TxD)
Pin 3 (TxD) to Pin 2 (RxD)
Pin 5 (Gnd) to Pin 6 (Gnd)
2
3
5
PC Side DB-9F
(back side of connector)
TB12 - Direct to PC Connection
Keri p/n: KDP-552
Keri p/n: KDP-929M
J7
LAN-520
Connection
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 4 of 10 P/N: 01553-001 Rev. D
1.4 Old-Style Platinum Controller
Figure 4: Old Style Entraguard Platinum Controller – p/n 05728-001
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 5 of 10 P/N: 01553-001 Rev. D
1.5 Board Placement for a PXL-500 Controller
Figure 5: Platinum Board Placement with an Optional PXL-500 Controller
NOTE: For information on the optional PXL-500/PXL-510 board, see the PXL-500 Installation Guide (P/N 01530-001).
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 6 of 10 P/N: 01553-001 Rev. D
2.0 Jumpers and LEDs
2.1 Jumpers
J14 – connects to the Postal Lock on the Old Style Platinum Controller
J16 – connects to the Postal Lock on the New Style Platinum Controller
J11 – requires a jumper to enable communication through the internal PC modem
J19 & J20 – requires jumpers to enable serial communication
J11, J19, and J20 must all be removed for LAN operation which is only available on New-Style Controller PCBs
2.2 LEDs
D32 – over current (Green), reversed current (Red)
D20, D18, D30, D25 – Relay active
D29 – RS-485 shield connected on master controller
D4, D5, D6 – RS-232 serial communication activity
3.0 Controller to Host PC Communication
There are two means of communication between controller and host PC: serial RS-232 or LAN.
3.1 Serial RS-232
An RS-232 serial port connection is made by either:
a direct serial connection (50 feet maximum)
through an internal PC modem or external modem
USB to serial converter – uses the Direct to PC serial connection
NOTE: If your PC has an internal modem, that modem may be prevented by the PC from properly operating with an
Entraguard controller. For modem connections, Keri recommends using an external modem for reliable operation.
Refer to the insets in Figure 3 and Figure 4 for RS-232 serial port wiring information.
LED D6 will be green when there is proper RS-232 serial communication.
3.2 LAN
A LAN connection is made using a LAN-520 device connected to J7 on the New Style Entraguard controller. Please refer
to the LAN-520X LAN Port Installation Guide (p/n 01504-001) for detailed information on configuring the LAN unit.
NOTE: LAN connectivity is not supported on the Old Style Controller board.
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 7 of 10 P/N: 01553-001 Rev. D
4.0 Setup Controller
If you're turning system power on for the first time, certain tasks must be performed prior to entering access control
information from Doors. On the EntraGuard Platinum main board (see Figure 3 on page 3 or Figure 4 on page 4), hold the
Reset Button (SW1) down and turn the controllers power on. After the controller beeps once, indicating the controllers
firmware is ready for programming, release the SW1 button. The LCD on the front panel will display the Reset Menu (see
Figure 6). From this menu you may perform these tasks:set the controllers address, clear the controllers memory, set the
microphone volume, run diagnostics, and set the LCD font.
Figure 6: Reset Menu
NOTE: If no keys have been selected within 60 seconds, the unit will time out and go directly to the default message. In
order to reach the Reset Menu, the unit must be powered up again.
4.1 Set Unit Address
The controllers address may only be set through the Reset Menu. To set the desired operating address for the controller,
press 1 on the keypad. The Set New Unit Address screen appears on the LCD (see Figure 7).
Figure 7: Set Unit Address
The address range is from 1 to 128. The Master Controller must be set to address 1. Other slave EntraGuard/PXL
controllers may be assigned any number from 2 to 128.
If the address shown as Current is correct, you may either enter the same address and press *, or just press * to return to
the reset menu. If you do not enter a new address, or enter the same address that is already assigned to this unit, you will
need to clear the memory separately (see “Clear the Controller’s RAM’’ on page 8).
NOTE: Changing the address of an EntraGuard Platinum controller completely erases all information within the
controller. It is vitally important that you collect all data from the controller before changing the address. Once the
address is changed (and the RAM is automatically cleared) the information in the controller is lost and cannot be
recovered.
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 8 of 10 P/N: 01553-001 Rev. D
If the address shown as Current needs to be changed, enter the new address by pressing the numbers on the keypad. The
number selected will show in the New line. If you enter the wrong number, simply press CLEAR to erase what has been
entered. When you are satisfied with the address entered, press *. If you have changed the number from what is shown as
Current, the controller will automatically clear the memory as it changes the address (see Figure 8).
Figure 8: Setting New Address
Once the memory has been cleared, the unit is ready to be configured. The LCD will display a warning that the unit has
not been initialized. This display will rotate with the EntraGuard Default display until a Total Update from Doors has been
performed on the unit. Once an update has been performed, only the default will be displayed.
4.2 Clear the Controller’s RAM
When turning system power on for the first time, the controllers memory needs to be cleared of any spurious information
that may be in the RAM. If you changed the controller address, the memory is automatically cleared. However, if you did
not change the address, you will need to clear the controllers RAM separately. From the Reset Menu (see Figure 6 on
page 7), press 2 to Clear Memory. The Clear Memory screen will appear on the LCD (see Figure 9).
Figure 9: Clear Memory
From the Clear Memory Screen you may either:
1. Press 1 to clear the controller’s RAM. The LCD will change to show the memory is being cleared (see Figure 10 on
page 9). Once the controllers RAM has been cleared, the unit is ready for use. The LCD will rotate between the
Initialization Warning and EntraGuard Default screens until a Total Update from Doors has been performed on the
unit.
OR
2. Press 2 to return to the Reset Menu without clearing the controllers RAM.
NOTE: Clearing the system RAM completely erases all information within the EntraGuard Platinum controller, except for
the controller address. If there is any information in system RAM from an access control installation and the system RAM
is cleared, the information in the controller is lost and cannot be recovered, and a Total Update must be performed.
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 9 of 10 P/N: 01553-001 Rev. D
Figure 10: Clearing Memory
4.3 Diagnostics and Troubleshooting
For information regarding the diagnostics screens and troubleshooting the EntraGuard Platinum Controller, see the
EntraGuard Troubleshooting and Diagnostics Guide (P/N 01912-001).
4.4 LCD Setup
The EntraGuard LCD (located on the front of the EntraGuard Platinum controller) is capable of using two different font
sizes. The default is set for the large size. However, if the small size font would be preferred as the default, it may be
changed through the reset menu. From the Reset Menu (see Figure 6 on page 7), press 5 for LCD Setup. The LCD Setup
menu will appear on the LCD (see Figure 11).
Figure 11: Setup LCD Menu
1. Select 5 on the keypad to change the default font size. The Set Font Default Menu appears (see Figure 12).
Figure 12: Set Font Default Menu
2. Press 1 to make the default font small.
3. Press 2 to make the default font large.
NOTE: Users may temporarily change the font size when using the EntraGuard Platinum controller, but any changes
made will always return to the default as selected here.
EntraGuard® Platinum Telephone Entry Controller
Installation Guide
Page 10 of 10 P/N: 01553-001 Rev. D
4. Once the font size is selected a Font set to small/large window appears (see Figure 13) corresponding to your
selection.
Figure 13: Font Set
5.0 Contact Keri Systems
- end of document -
Keri USA Keri UK, Ireland, Europe
2305 Bering Drive
San Jose, CA 95131 Unit 17
Park Farm Industrial Estate
Ermine Street
Buntingford
Herts SG9 9AZ UK
Telephone: (800) 260-5265
(408) 435-8400 Telephone: + 44 (0) 1763 273 243
Fax: (408) 577-1792 Fax:+ 44 (0) 1763 274 106
Web: www.kerisys.com Web:www.kerisystems.co.uk
E-mail: sales@kerisys.com
techsupport@kerisys.com E-mail:sales@kerisystems.co.uk
tech-support@kerisystems.co.uk