Landis Gyr Technology NG1R1S1 NIC AM User Manual Manual
Landis+Gyr Technology, Inc. NIC AM Manual
Contents
- 1. Manual
- 2. User Manual
Manual
Certification Exhibit FCC ID: R7PNG1R1S1 IC: 5294A-NG1R1S1 FCC Rule Part: 15.247 ISED Canada Radio Standards Specification: RSS-247 Project Number: 72127440 Manufacturer: Landis+Gyr Technology, Inc. Model: NIC AM Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Review Draft 5/2/2018 Landis+Gyr Network Bridge N2200/N2250 Data Sheet Publication: 98-1822 Rev AA LANDIS+GYR CONFIDENTIAL INFORMATION Review Draft 5/2/2018 Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr. In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages. © 2018 Landis+Gyr, Inc. All Rights Reserved Covered by both issued and pending patents. For further patent information see: https://www.landisgyr.com/about/patent-notices/ Landis+Gyr Network Bridge N2200/N2250 Data Sheet Publication: 98-1822 Rev AA Revision History Modification Date Revision Description Author AA In Progress Vicky Costello © 2018 Landis+Gyr • All rights reserved Contact Us: Landis+Gyr technical support: 1-888-390-5733 solutionsupport.na@landisgyr.com To provide feedback about this documentation, contact the Technical Documentation team at: ustechnicaldocumentation@landisgyr.com. Review Draft 5/2/2018 Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Product Overview The Landis+Gyr Network Bridge provides the basis for a powerful RF wireless mesh network for remote data collection and end device monitoring and control. The Network Bridge supports full two-way peer-to-peer communication to all devices within the network. The product offers advanced functionality, such as individual message prioritization, additional memory for localized intelligence, and it is based on the Linux operating system. The N2200 (RF Mesh)/N2250 (RF Mesh IP) provides interface and control to distribution equipment and critical devices that require low latency. Figure 1 - 1. N2200/N2250 Network Bridge In addition to the standard RF Mesh and RF Mesh IP radios, the N2200/N2250 has one internal slot that can be fitted with LTE wireless or other future WAN technologies. The N2200/N2250 comes equipped with two serial, two Ethernet ports and WiFi for configuration. Landis+Gyr's Network Bridge/Network Gateway Platform offers a family of Field Area Data Sheet 98-1822 Rev AA Review Draft 5/2/2018 Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Landis+Gyr Network Devices that can be configured and deployed to build a robust communication network infrastructure enabling communication to edge devices in the field. Dimensions Figure 1 - 2. Network Bridge Physical Dimensions 98-1822 Rev AA Data Sheet Review Draft 5/2/2018 Landis+Gyr Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet N2200/N2250 Specifications Product Specifications Table 1 lists the general product specifications for the N2200 (RF Mesh)/N2250 (RF Mesh IP) Network Bridge Series. Table 1. Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Product Specifications Element Description Electrical (General) Input Voltage Range 12-24 VDC +/- 20% (9.6-28.8 VDC) Current 1.39A-0.45A Processing Unit CPU Cortex A5 Clock Speed 536 MHz RAM Memory 512 Mbytes DDR2 RAM FLASH Memory 2 GB NAND Bridge Radio Processing Unit CPU Dual-core Cortex M4, AMTEL SAM4C32A Clock Speed 120 MHz RAM Memory 304 Kbytes FLASH Memory 2 MB + 4MB External ROM Memory 8 Kbytes LAN Packet Port Serial Interface RS-232C/RS-485; RJ45; 1200 to 115,200 bps Protocol Gridstream LAN Packet Protocol Parity None Data Bits Stop Bits Duplex Full Transparent Port Data Sheet Serial Interface RS-232C/RS-485; RJ45; 1200 to 115,200 bps Protocol Any Asynchronous Byte-Oriented Protocol Parity None Data Bits 7 or 8 Stop Bits 1 or 2 Duplex Full 98-1822 Rev AA Review Draft 5/2/2018 Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Landis+Gyr Table 1. Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Product Specifications (Continued) Element Description Ethernet ETH 0 10/100/1000 Ethernet ETH 1 10/100 Ethernet WIFI Manufacturer Redpine Signals Model RS9113 n-Link™ Manufacturer Part Number RS9113-NBZ-D3N LTE Cat6 (US Only-ATT and Verizon) Manufacturer Sierra Wireless Model MC Series Manufacturer Part Number MC7455 Mechanical Enclosure Black Anodized Aluminum, IP41 Dimensions 55.20mm W X 120.00mm D X 112.10mm H Weight 1.10 lbs Operating Temperature Range -40°C to 60°C Storage Temperature Range -40°C to 85° C Limited Lifetime Life 20 years 98-1822 Rev AA Data Sheet Review Draft 5/2/2018 Landis+Gyr Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Radio Specifications Americas Table 2 lists the radio specifications for the N2200 (RF Mesh)/N2250 (RF Mesh IP) Network Bridge Series for Americas. Table 2. Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Radio Specifications Americas Element Description Radio (General) Radio Model Model: NIC AM Communication Protocol (PHY) IEEE 802.15.4-2015 - SUN FSK PHY North America: 902-928 MHz RF Frequency Range Brazil: 902-907.5, 915-928 MHz N2250 (RF Mesh IP): 200, 400 KHz Channel Spacing N2200 (RF Mesh): 100, 300 KHz N2250 (RF Mesh IP): 50, 150, 200 Kbps RF Data Rate N2200 (RF Mesh): 9.6, 19.2, 38.4, 115.2 Kbps Receiver -106 dBm(50 Kbps) Sensitivity (at 10% packet error rate) -101 dBm(150 Kbps) -98 dBm(200 Kbps) Adjacent Channel Rejection 35 dB Typical Alternate Channel Rejection 50 dB Typical Transmitter Output Power (at Antenna Connector) 50 mW to 1W Modulation Type 2FSK Out-of-band Spurious Emissions <-70 dBc Antenna Requirements Data Sheet Type Vertically polarized, omnidirectional Gain < 5.5 dBi Connector N Connector, Female 98-1822 Rev AA Review Draft 5/2/2018 Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Landis+Gyr Radio Specifications India Table 3 lists the radio specifications for the N2200 (RF Mesh)/N2250 (RF Mesh IP) Network Bridge Series for India. Table 3. Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Radio Specifications India Element Description Radio (General) Radio Model Model: NIC IN Communication Protocol (PHY) IEEE 802.15.4-2015 - SUN FSK PHY RF Frequency Range 865-867 MHz N2250 (RF Mesh IP): 200 KHz Channel Spacing N2200 (RF Mesh): 100 KHz N2250 (RF Mesh IP): 50, 100, 150 Kbps RF Data Rate N2200 (RF Mesh): 9.6, 19.2, 38.4 Kbps Receiver -106 dBm (50 Kbps) Sensitivity (at 10% packet error rate) -101 dBm (150 Kbps) -98 dBm (200 Kbps) Adjacent Channel Rejection 35 dB Typical (50 Kbps) Alternate Channel Rejection 50 dB Typical (50 Kbps) Transmitter Output Power (at Antenna Connector) 50 mW to 1W Modulation Type 2FSK Out-of-band Spurious Emissions >70 dBc Antenna Requirements Type Vertically polarized, omnidirectional Gain < 5.5 dBi Connector N Connector, Female 98-1822 Rev AA Data Sheet Review Draft 5/2/2018 Landis+Gyr Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Regulatory Compliance FCC Compliance FCC Class B This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Consult Landis+Gyr or an experienced radio technician for help WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the user’s authority to operate the equipment. RF Exposure This equipment complies with FCC and ISED radiation exposure limits. This equipment should be installed and operated with a minimum distance of 28 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet équipement est conforme aux limites FCC/IC d'exposition aux radiations définies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé à une distance minimale de 28cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-implantés ou exploités en conjonction avec une autre antenne ou émetteur. Data Sheet 98-1822 Rev AA Review Draft 5/2/2018 Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Landis+Gyr EIRP Limit The equipment meets the required FCC specifications with any customer-selectable RF power setting of the radio, using the antennas indicated in this document. FCC testing was conducted using an omnidirectional whip antenna with a gain of 5 dBi. Omnidirectional whip antennas with higher gain may result in EIRP levels in excess of the FCC limit. Antennas of a type other than omnidirectional whip are not FCC approved for this device. NOTE: If you increase the power from the factory settings, this can cause communication problems for other radios in the network. FCC ID Labels FCC ID Label contents are shown in Figure 2 and Figure 3. Figure 2. FCC ID Label (RF Mesh) 10 98-1822 Rev AA Data Sheet Review Draft 5/2/2018 Landis+Gyr Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Figure 3. FCC ID Label (RF Mesh IP) Requirement for Hosting Certified Radios The following radio modules are approved for use in the Bridge. • NIC • Cell Modems • WiFi Transmitters that are added to the Bridge require testing to be approved. • If the transmitters are added by the customer, the customer is responsible for this testing. • If Landis+Gyr adds these modules, the testing will be performed, and they will be added to the list of approved modules. Industry Canada This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (identify the device by certification number, or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each Data Sheet 98-1822 Rev AA 11 Review Draft 5/2/2018 Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Landis+Gyr antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. This radio transmitter (5294A-NG1R1S1) has been approved by Industry Canada. Approved Antenna: Omni-directional antenna, 5.5 dBi gain, 902-928 MHz, antenna impedance is 50 ohms. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s'il fait partie du matériel de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. Brazil Anatel Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário. Regulatory Compliance India WPC Guidelines This device complies with WPC guidelines. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. 12 98-1822 Rev AA Data Sheet Review Draft 5/2/2018 Landis+Gyr Network Bridge N2200 (RF Mesh)/N2250 (RF Mesh IP) Data Sheet Safety Information California Hazard Identification Data Sheet WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. 98-1822 Rev AA 13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 14 Language : en-US Tagged PDF : Yes Has XFA : No Producer : Foxit PhantomPDF Printer Version 7.3.4.0308 Author : Creator : Subject : Title : Modify Date : 2018:05:03 09:49:59-05:00EXIF Metadata provided by EXIF.tools