Leviton DDMX1 Remote Dimmer Switch User Manual DI 000 DDMX1 02A X3 indd
Leviton Manufacturing Co., Inc. Remote Dimmer Switch DI 000 DDMX1 02A X3 indd
Leviton >
Contents
- 1. User Manual_20160119_v1 - User Manual - DI-000-DDMX1-02A-X3 english manual
- 2. User Manual_20161215_v1 - 11-11412386 - Use Manuals
User Manual_20160119_v1 - User Manual - DI-000-DDMX1-02A-X3 english manual
PRELIMINARY
Single Pole (One location) or 3-Way (Multi-location)
Universal Incandescent/Magnetic Low Voltage/Fluorescent or LED Dimmer
Cat. No. DDMX1-BL, 1000VA, 1000W, 450W LED/CFL (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
IMPORTANT: For 3-Way applications, note that one of the screw terminals
from the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the dimmer wall box and remote wall box.
For non-standard wiring applications, refer
to Wire Nut and Connector Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
DI-000-DDMX1-02A-X3
• Pull off pre-cut insulation from dimmer leads.
• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
• Remove insulation from each wire in the wall box as shown.
• For Single-Pole Application, go to Step 4a.
• For 3-Way Matching Remote (w/LEDs) Application, go to Step
4b.
Step 4b
TOOLS NEEDED TO INSTALL YOUR DIMMER
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the reduction of the dimmer’s capacity may
be required. Refer to the chart for maximum load per dimmer.
NOTE: No derating is required for LED or CFL bulb applications.
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF
OR WITH OTHER DEVICES
Changing the color of your Dimmer:
Your device may include color options. To change color of the face
proceed as follows:
1
2
Insert top tabs and
press in bottom tabs
to attach
Push in sides at bottom
tabs and pull outward to
release
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
Step 1
Step 2
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any
of these configurations, consult an electrician.
2
4
3
1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
3-Way
1. Line or Load
(see important
instruction)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
2
4
1
5
3
Cut
(if necessary)
5/8"
(1.6 cm) Strip Gage
(measure bare
wire here)
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary). Remove insulation from each wire in the wall box
as shown:
Step 3
Dimmer
Insulating
Label
Black
Load
Hot (Black)Black
Line
120 VAC,
60Hz
Neutral (White)
Red
Yellow/Red
White
White
Green
Ground
White
Red
Green
Black 1
4
2
3
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove insulating label.
Yellow/Red
Single Pole Wiring Application:
Step 4a
MAXIMUM BULB WATTAGE
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage
is determined by the efficiency of the transformer in the low-voltage lighting
system. Transformer efficiencies will vary from different manufacturers;
consider 80% efficient as average. Use the chart to determine maximum bulb
wattage for typical transformer efficiency ratings.
MAXIMUM BULB WATTAGE
Mark 10
®
Powerline dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the efficiency of the Mark 10
®
Powerline ballast. The
following table shows the maximum number of ballasts that can be connected
to a single dimmer for different Mark 10
®
Powerline ballasts. Also note that the
table shows maximum ballasts for multi-gang installations.
Lutron Tu-Wire®:
To determine total ballast load, add the line current found on the ballast label
for all ballasts in the circuit. This will indicate the total load for the control.
Remove all
inner side
sections
Do not
remove
outer side
sections
Bend back and
forth to remove
side section
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than 2 Devices
700W
700VA
Two Devices
800W
800VA
Single
1000W
1000VA
Load
Incand
Mag LV
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
More than 2 Gang
560W
Rating
1000VA
Single
800W
Two Gang
640W
INTRODUCTION
The next generation of lighting control technology is here with the new
Decora® Digital Dimmer with Bluetooth® Technology. This innovative
device works using the Leviton Decora® Digital Dimmer & Timer app
that can be easily downloaded to smartphones or tablets and paired
to the Leviton Dimmer using Bluetooth® technology. Decora® Digital
Devices give users point-to-point local control to automate lighting,
bridging the gap between standard dimmers and whole-house
automation systems.
The Decora® Digital Dimmer is a powerful device – combining the best
of Leviton dimmer and timer functions with today’s mobile technology
for impressive results. The simple touch of a finger following the
intuitive on-screen guide makes it more convenient than ever to
manage lighting for home activities or to ensure a "lived-in" look while
away. Plus, the Decora® Digital Dimmer is Universal and compatible
with LED, CFL, Incandescent, Halogen or Mark 10® Powerline loads.
Use of the app allows greater flexibility for accurate timer functionality
and makes pushing buttons for timed events a tedious chore of the
past.
The Leviton Decora® Digital Dimmer & Timer app can be easily
downloaded to mobile devices and is compatible with Android and iOS
smartphones or tablets. The app is easy to use with simple, intuitive
on-screen menu options to independently control dimmers and
switches throughout the home.
Decora® Digital Devices are ideal for living rooms, bedrooms, kitchens,
dining rooms, home offices, outdoor lighting or anywhere full control of
lighting is desired.
• Soft fade ON/OFF
• ON/OFF LED and Brightness level LED
• Three way communication
• Ease of installation – No new wiring
FEATURES
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING: CONNECT A MAGNETIC LOW-VOLTAGE DIMMER ONLY
TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC
LOW-VOLTAGE TRANSFORMER.
NOTE: The DDMX1 dimmer requires a neutral wire connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot wall box wire to Black dimmer lead.
• Load wall box wire to Red dimmer lead.
• Line Neutral wall box wire to White dimmer lead.
• Yellow/Red dimmer lead should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use
electrical tape to cover.
• Proceed to Step 5.
Cat. No. DDMX1, 120V, For use with Advance Transformer
120V Mark 10
®
Powerline Electronic Ballasts
Max. # Ballasts/Dimmer for
Multi-gang
Advance
Mark 10®
Powerline
Part No.
Lamp Single
Gang
Two
Ganged
More than
2 Gang
REZ-2Q18-M2-LD
REZ-1T32
REZ-2Q26
REZ-1T32
REZ-1T42
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-1T32
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-2Q18-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2T42-M3-BS CFTR32W/GX24Q 13 10 8
CFTR32W/GX24Q 26 20 16
CFTR32W/GX24Q 26 20 16
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 17 13 11
CFTR26W/GX24Q 32 25 20
CFTR26W/GX24Q 32 25 20
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 23 18 15
CFTR18W/GX24Q 46 37 30
CFTR18W/GX24Q 46 37 30
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 17 13 11
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ26W/G24Q 32 25 20
CFQ18W/G24Q 23 18 15
CFQ18W/G24Q 46 37 30
CFQ18W/G24Q 46 37 30
CFM42W/GX24Q 20 16 13
CFM32W/GX24Q 26 20 16
CFM26W/GX24Q 17 13 11
CFM26W/GX24Q 32 25 20
151823CFM18W/GX24Q
WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
•
TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor- or a transformer-operated appliance.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
• Use ONLY with the appropriate Advance Transformer 120V Mark 10® Powerline or Lutron Tu-Wire® electronic ballasts for controlling the specific fluorescent lamps in Fluorescent Mode.
• Use with magnetic low voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.
• When retrofitting Mark 10® Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper dimmer
operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.
• The Decora
®
DDMX1 dimmer is not compatible with standard 3-way or 4-way switches. It must be used with the
Decora
®
Digital DD00R-DL remote for multi-location dimming
.
WARNINGS AND CAUTIONS:
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Dimmer may feel warm to the touch during normal operation.
• When magnetic low voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible transformer failure due to
overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings.
• Recommended minimum wall box depth is 2-3/4".
• Use this device WITH COPPER OR COPPER CLAD WIRE ONLY.
• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.
• When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance
dimmer performance.
WIRING MATCHING REMOTE (wall box with line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The matching remote must be installed in a wall box with a
Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked "BK".
• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The DDMX1 dimmer must be installed in a wall box that has a
Load connection and a Neutral connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.
• First Traveler Line Hot to Black dimmer lead.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to
the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White dimmer lead.
• Proceed to Step 5.
Hot (Black)
Neutral (White)
Dimmer
Matching Remote (w/LEDs)
YL/RD
Red
Yellow/
Red
WH BK
Black
Black
White
Line
120V
AC, 60Hz
Green
Ground
Green
Ground
White Load
3-Way Wiring with DD00R Matching Remote
(w/LEDs) Application:
Matching Remote Dimmer
Additional Neutral Wire
White
Red
Green
Black
1
2
3
Yellow/Red
4
5
1
2
3
4
5
PRELIMINARY
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details
visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating
conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose,
is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
ADVANCED PROGRAMMING FEATURES
Definition of A Modes
A-1) Load Type Selection
A-2) Energy Save: Sets the maximum brightness level for energy
savings.
A-3) Minimum Brightness Level: Sets the minimum dimming level.
A-4) Preset ON Level: Sets the turn on brightness level regardless of
the previous set light level.
Definition of B Modes
B-1) ON Fade Rate: Sets the amount of time in seconds it takes the
lights to turn ON to maximum brightness.
B-2) OFF Fade Rate: Sets the amount of time in seconds it takes the
lights to turn OFF from maximum brightness.
B-3) LED Options: Sets the time period in seconds the Locator LED
and Brightness display will stay on before extinguishing.
B-3)
The Locator LED will blink 3 times per second to indicate Program
Mode B-3, LED Options. To change the LED Options settings, use
the DIM/BRIGHT Bar to move the LED to the desired preset setting
according to the LED Options Chart. By tapping the Top of the
Rocker this setting will automatically be saved and the device will exit
Programming Mode B.
Program Mode A
To enter Program Mode A:
Press and hold the TOP of the Rocker and the TOP of the DIM/BRIGHT
Bar simultaneously for 5 seconds until the Locator LED begins to blink.
A-1) Upon releasing the TOP of the Rocker and the TOP of the DIM/
BRIGHT Bar, the Locator LED will continue to blink once per
second to display the device is in Program Mode A-1, Load Type
Selection. The bottom LED will illuminate to display that the Load
Type selected is Incandescent/MLV load (default load type). To
change the load type, use the DIM/BRIGHT Bar to change the
corresponding LED to the desired load type according to the Load
Type Chart below. By tapping the TOP of the Rocker, this setting
will automatically be saved and the device will advance to the next
Programming Mode, A-2, Energy Save (Maximum Brightness
Level).
LED 7 Dim/
Bright
Bar
Locator LED
LED 1
Definition of LEDs
Bottom LED = LED 1
Top LED = LED 7
NOTES:
• The device will exit programming
mode after 3 minutes of inactivity.
• Pressing the TOP of the Rocker at
any time during programming will
advance the device to the next
programming mode.
DIM/BRIGHT Bar
BRIGHTEN:
Press the TOP half of the DIM/BRIGHT Bar – Lights brighten to desired
level.
DIM:
Press the BOTTOM half of the DIM/BRIGHT Bar – Lights dim to desired
level.
If you continue to hold, the lights will DIM to minimum level and
then turn OFF.
NOTE: When lights are OFF you can change the light level that the
lights will turn ON to using the DIM/BRIGHT Bar. If there is a power
outage, when the power is restored, the lights will return to the last
setting before the power interruption.
NOTE: The locator light will illuminate when
the load is in the OFF position to facilitate
access in the dark.
NOTE: If using the dimmer in a 3-way
application, the lights will turn ON at
brightness set on dimmer’s DIM/BRIGHT bar.
The lighting can be controlled from either the
dimmer, the remote location or the mobile
device app.
Push Pad (Default settings)
Turn ON from OFF position:
Tap TOP of Rocker: Lights turn ON to preset
level.
Turn OFF from ON position:
Tap BOTTOM of Rocker. Lights turn OFF.
OPERATION LED Brightness
Display
DIM/BRIGHT
Bar
Rocker Locator
Light
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
Gently pull out
from bottom
Air-Gap Switch: On the dimmer only, engage
the air-gap switch by gently pulling out from the
bottom of the DIM/BRIGHT bar until the bottom
of the bar lifts completely out of the frame and a
click is heard (refer to Figure). LED's will turn
OFF. This will stop power to the fixture to replace
the bulb. After servicing is complete, press the
DIM/BRIGHT Bar back into place for normal
operation.
Download the Leviton Decora® Digital Dimmer & Timer App for
your device.
Android: Tap the Google Play Store icon on your phone or go to
http://play.google.com on your computer and follow the
instructions to obtain the app.
iPhone: Tap the App Store icon on your phone or access the app
through your iTunes account on your computer.
Once you have downloaded the app, follow the instructions on the screen
to pair your mobile device with your dimmer. Once your mobile device is
paired, use the following options to control your dimmer:
• On - Off: Turns the dimmer ON and OFF.
• Schedule: Creates distinct ON/OFF events based on time and day.
• Sleep Timer: Sets countdown to turn dimmer OFF.
Advanced Settings
Device Options
• Randomized Scheduled Events: Cycles lights ON and OFF to
ensure a "lived-in" look while away.
• Hide LED Dim Bar: Turns LED Dim Bar OFF.
• Hide Status LED: Turns Status LED OFF.
• DST Offset Hours: Adjusts the Sunrise/Sunset time in hours.
• DST Offset Minutes: Adjusts the Sunrise/Sunset time in minutes.
Bulb Options
• Load Type: Sets load type to Incandescent/Magnetic Low-Voltage,
LED, CFL or Mark 10®.
• Fade On: Sets the amount of time for the lights to turn ON to
maximum brightness.
• Fade Off: Sets the amount of time for the lights to turn to OFF from
maximum brightness.
Lighting Options
• Preset: Sets the brightness level at which the lights turn ON.
• Minimum: Sets a minimum brightness level for lighting.
• Maximum: Sets a maximum brightness level for lighting.
DI-000-DDMX1-02A-X3
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors of dimmer or
terminal screws of remote.
- If using in a dimmable fluorescent application see Advanced
Programming Feature A-1.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Neutral not wired to Dimmer (White wire).
- Confirm that the device is being supplied from a 120V, 60 Hz AC
source ONLY.
• I ntermittent dimmer operation
- Confirm that the Load being controlled does not exceed the
1000VA dimmer limit.
• Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
- Ensure wiring is correct.
TROUBLESHOOTING CONTROLLING YOUR DIMMER WITH BLUETOOTH®
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
• Restore power at circuit breaker or fuse.
• Press pad until locator light is OFF. Lights
should turn ON. If lights do not turn ON,
press the TOP half of the DIM/BRIGHT
Bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Testing your Dimmer prior to mounting in
wall box:
Step 5
• Position all wires to provide room
in outlet wall box for device.
• Ensure that the word “TOP” is
facing up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when mounting device.
NOTE: If using in a dimmable fluorescent application see
Advanced Programming Feature A-1 prior to testing the device.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada
should contact Leviton in writing at Leviton Manufacturing of Canada
Ltd to the attention of the Quality Assurance Department, 165
Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by
telephone at 1-800-405-5320.
Dimmer Mounting:
TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE.
Step 6
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
If your dimmer is not responding, or you are unable to control it after
you have tried to Pair/Connect to it multiple times, it may be necessary
to reset the dimmer to its original factory settings. To accomplish this,
proceed as follows:
On the dimmer, hold the TOP of the rocker until the locator LED starts
to blink. The dimmer is now reset. Once the dimmer is reset, it may be
necessary to re-pair with the your application.
N
OTE: To pair your dimmer with your mobile device, download the
Leviton Decora® Digital Dimmer and Timer app from the Google Play
Store or your iTunes account. Contact Leviton’s Techline at 1-800-
824-3005 or visit Leviton’s website at www.leviton.com for additional
information.
FACTORY DEFAULT
This device complies with Part 15 of the FCC Rules. Operation is subject to
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a
Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF
and ON, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton
Manufacturing Co., Inc., could void the user's authority to operate the
equipment.
FCC COMPLIANCE STATEMENT
Copyright and Trademark Information
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc., used under license by Leviton.
Use herein of third party trademarks, service marks, trade names, brand
names and/or product names are for informational purposes only, are/may
be the trademarks of their respective owners; such use is not meant to imply
affiliation, sponsorship, or endorsement.
No part of this document may be reproduced, transmitted or transcribed
without the express written permission of Leviton Manufacturing Co., Inc.
This product is covered by U.S. Patent No. 8,664,886 and corresponding
foreign patents.
© 2015 Leviton Mfg. Co., Inc.
Program Mode B
To enter Program Mode B:
Press and hold the TOP of the Rocker and then the BOTTOM of the DIM/
BRIGHT Bar for 5 seconds until the Locator LED and the TOP LED (LED 7)
begin to blink.
B-1) Upon releasing the TOP of the Rocker and the BOTTOM of the DIM/
BRIGHT Bar, the Locator LED will continue to blink once per second
indicating the dimmer is in Program Mode B-1, ON Fade Rate. To
change the ON Fade Rate, use the DIM/BRIGHT Bar to move the
LED to the desired preset level according to the Fade Rate Chart. By
tapping the Top of the Rocker this setting will automatically be saved
and the device will advance to the next programming mode, B-2, OFF
Fade Rate.
B-2) The Locator LED will blink 2 times per second to indicate Program
Mode B-2, OFF Fade Rate. To change the OFF Fade Rate, use
the DIM/BRIGHT Bar to move the LED to the desired preset level
according to the Fade Rate Chart. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to
the next programming mode, B-3 LED Options.
A-2) Energy Save (Maximum Brightness Level): NOTE - Energy Save
Mode can only be used with an incandescent or magnetic low voltage
load. The Locator LED will blink 2 times per second to indicate the
device is in Program Mode A-2, Energy Save (Maximum Brightness
Level).The default Energy Save Mode is 100% i.e. full bright. To
change the Energy Save level, use the DIM/BRIGHT Bar to move
the corresponding LED to the desired discreet preset level according
to the Energy Save Chart. By tapping the TOP of the Rocker this
setting will automatically be saved and the device will advance to the
next Programming Mode, A-3, Minimum Brightness Level.
LOAD TYPE CHART
When indicator is at LED # Selected Load Type is
1 Incandescent/MLV
2 LED
3 CFL
4 Mark 10®
ENERGY SAVE CHART
When indicator is at
LED # Light output is at Energy consumption
savings amount to
7 100% 0%
6 97% 5%
5 95% 8%
4 90% 11%
3 85% 14%
2 80% 17%
1 75% 20%
FADE RATE CHART
LED Fade ON Fade OFF
1 0 seconds (instant) 0 seconds (instant)
2 0.5 seconds 0.5 seconds
3 1.5 seconds 1.5 seconds
4 3 seconds 3 seconds
5 6 seconds 6 seconds
6 10 seconds 10 seconds
7 25 seconds 25 seconds
LED OPTIONS CHART
LED Locator LED Timeout LED Brightness Display Options
1 Active Active
2 Active Turns OFF 5 seconds after use
3 Turns OFF 5 seconds after use Active
4 Turns OFF 5 seconds after use Turns OFF 5 seconds after use
5 N/A N/A
6 N/A N/A
7 N/A N/A
A-3)
The Locator LED will blink 3 times per second to indicate the device is in
Program Mode A-3, Minimum Brightness Level. The default Minimum
Brightness Level is LED 2. To change the Minimum Brightness Level
from 1-50%, use the DIM/BRIGHT Bar. The light output will reflect the
minimum brightness level selected. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to the
next programming mode, A-4, Preset ON Level.
A-4)
The Locator LED will blink 4 times per second to indicate Program
Mode A-4, Preset ON Level. To change the current Preset ON
Level from 1-100%, use the DIM/BRIGHT Bar. If this feature is not
desired, press and hold the BOTTOM half of the DIM/BRIGHT Bar
until no LED is lit (default setting). By tapping the TOP of the Rocker
this setting will automatically be saved and the device will exit
Programming Mode A.
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired
operation of the device.
PRELIMINARY
ARTWORK PRINT SPECIFICATIONS
DIMENSIONS / FOLD SCHEME / BINDERY DIAGRAM
PART NUMBER REV DESCRIPTION
Line Screen:
Angle:
Resolution:
Offset Flexo
Other
Body Material:
Bindery
Thickness:
Trim
Perfect Bind
Die cut Saddle Stitch
Drill
Fold
The information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY, INC. It is disclosed
with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict
confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any purpose other than that for which disclosed.
PlantApprovals:
PN-ARN: Pilot Rev:ECR Number:
Released Artwork Format: Production PDF Artwork Release Date:
Artwork Print Specification Sheet Rev A11.eps
PMCQA
Artist:
Notes:
Other
Cust Other
S & A
Mktg Eng
FOR LEVITON USE ONLY
SPECIFICATIONS :
PROCESS :
MANUAL INTERIORS / BINDERY / FOLD SCHEME :
COMMENTS :
For manuals - designates cover specifications
Material:
Thickness:
Finish:
:
Spot
CMYK
1:
4:
3:
2:
Colors: over
1:
4:
3:
2:
Fonts:
Spot
CMYK
1:
4:
3:
2:
Colors: over
1:
4:
3:
2:
Fonts:
Fold Line
Die Cut Punch/Drill Hole
Glue
Kiss Cut Cellophane
Fold Line
Perforate
Die Cut
Die Line Key:
DI-000-DDMX1-02A-X3 Instruction sheet
HelveticaBlack
11
X
X
X
D. Hunt
HD0085-4848
J. Tang 08 B. Grande
C. ButtittaV. LoNigro
K. Cohen
40 lb.
F. Tse
11"
17"
Part No.
FINAL
2.75"
4.25"
Part No.
X X
XX
XX
RS0263-4912 - French completed under this Art Request number.