Leviton DDMX1 Remote Dimmer Switch User Manual DI 000 DDMX1 02A X3 indd

Leviton Manufacturing Co., Inc. Remote Dimmer Switch DI 000 DDMX1 02A X3 indd

Contents

User Manual_20160119_v1 - User Manual - DI-000-DDMX1-02A-X3 english manual

Download: Leviton DDMX1 Remote Dimmer Switch User Manual DI 000 DDMX1 02A X3 indd
Mirror Download [FCC.gov]Leviton DDMX1 Remote Dimmer Switch User Manual DI 000 DDMX1 02A X3 indd
Document ID2910521
Application IDmLJptxuk1SKpWTQzqx+O1w==
Document DescriptionUser Manual_20160119_v1 - User Manual - DI-000-DDMX1-02A-X3 english manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize103.92kB (1299061 bits)
Date Submitted2016-02-24 00:00:00
Date Available2016-02-24 00:00:00
Creation Date2015-12-07 13:57:14
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2015-12-07 13:57:46
Document TitleDI-000-DDMX1-02A-X3.indd
Document CreatorAdobe InDesign CC 2015 (Macintosh)

Single Pole (One location) or 3-Way (Multi-location)
Universal Incandescent/Magnetic Low Voltage/Fluorescent or LED Dimmer
Cat. No. DDMX1-BL, 1000VA, 1000W, 450W LED/CFL (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
FEATURES
Soft fade ON/OFF
ON/OFF LED and Brightness level LED
Three way communication
Ease of installation – No new wiring
To determine total ballast load, add the line current found on the ballast label
for all ballasts in the circuit. This will indicate the total load for the control.
Remove all
inner side
sections
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Load
Single
Two Devices
More than 2 Devices
Incand
1000W
800W
700W
Mag LV
1000VA
800VA
700VA
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage
is determined by the efficiency of the transformer in the low-voltage lighting
system. Transformer efficiencies will vary from different manufacturers;
consider 80% efficient as average. Use the chart to determine maximum bulb
wattage for typical transformer efficiency ratings.
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Rating
Single
Two Gang
More than 2 Gang
1000VA
800W
640W
560W
Your device may include color options. To change color of the face
proceed as follows:
Insert top tabs and
press in bottom tabs
to attach
INSTALLING DIMMER BY ITSELF
OR WITH OTHER DEVICES
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
CFM18W/GX24Q
CFM26W/GX24Q
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ18W/G24Q
CFQ18W/G24Q
CFQ18W/G24Q
CFQ26W/G24Q
CFQ26W/G24Q
CFQ26W/G24Q
CFQ26W/G24Q
CFQ26W/G24Q
CFQ26W/G24Q
CFTR18W/GX24Q
CFTR18W/GX24Q
CFTR18W/GX24Q
CFTR18W/GX24Q
CFTR26W/GX24Q
CFTR26W/GX24Q
CFTR26W/GX24Q
CFTR26W/GX24Q
CFTR32W/GX24Q
CFTR32W/GX24Q
CFTR32W/GX24Q
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Max. # Ballasts/Dimmer for
Multi-gang
Single
Gang
Two
Ganged
More than
2 Gang
23
32
17
26
20
46
46
23
32
32
32
17
17
17
46
46
23
23
32
32
17
17
26
26
13
18
25
13
20
16
37
37
18
25
25
25
13
13
13
37
37
18
18
25
25
13
13
20
20
10
15
20
11
16
13
30
30
15
20
20
20
11
11
11
30
30
15
15
20
20
11
11
16
16
Step 3 Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary). Remove insulation from each wire in the wall box
as shown:
5/8"
(1.6 cm)
Cut
(if necessary)
Strip Gage
(measure bare
wire here)
• Pull off pre-cut insulation from dimmer leads.
• Make sure that the ends of the wires from the wall box are straight
(cut if necessary).
• Remove insulation from each wire in the wall box as shown.
• For Single-Pole Application, go to Step 4a.
• For 3-Way Matching Remote (w/LEDs) Application, go to Step
4b.
Red
Black
Green
Yellow/Red
White
Green
Hot (Black)
Yellow/Red
Load
Insulating
Label
Black
WH
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove insulating label.
Black
Dimmer
Matching Remote (w/LEDs)
Yellow/Red
Red
3-Way
1. Line or Load
(see important
instruction)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
IMPORTANT: For 3-Way applications, note that one of the screw terminals
from the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the dimmer wall box and remote wall box.
Dimmer
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
White
Black
Red
LI
Cat. No. DDMX1, 120V, For use with Advance Transformer
120V Mark 10® Powerline Electronic Ballasts
REZ-2Q18-M2-LD
REZ-1T32
REZ-2Q26
REZ-1T32
REZ-1T42
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-1T32
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1Q18-M2-BS
REZ-1Q18-M2-LD
REZ-2Q18-M2-BS
REZ-2Q18-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2Q26-M2-BS
REZ-2Q26-M2-LD
REZ-1T42-M2-BS
REZ-1T42-M2-LD
REZ-2T42-M3-BS
OFF
ON
OFF
Dimmer
Additional Neutral Wire
Step 4a Single Pole Wiring Application:
NOTE: If the wiring in your wall box does not resemble any
of these configurations, consult an electrician.
Changing the color of your Dimmer:
Mark 10® Powerline dimmers are rated in Volt-Amps (VA). The maximum bulb
wattage is determined by the efficiency of the Mark 10® Powerline ballast. The
following table shows the maximum number of ballasts that can be connected
to a single dimmer for different Mark 10® Powerline ballasts. Also note that the
table shows maximum ballasts for multi-gang installations.
Lamp
ON
OFF
Matching Remote
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
Step 2 Identifying your wiring application (most common):
MAXIMUM BULB WATTAGE
Advance
Mark 10®
Powerline
Part No.
OFF
3-Way Wiring with DD00R Matching Remote
(w/LEDs) Application:
Step 4b
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
Do not
remove
outer side
sections
Bend back and
forth to remove
side section
when Steps are completed.
For non-standard wiring applications, refer
to Wire Nut and Connector Size Chart
Step 1 WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil			Cutters		Ruler
INSTALLING YOUR DIMMER
NOTE: Use check boxes
MAXIMUM BULB WATTAGE
TOOLS NEEDED TO INSTALL YOUR DIMMER
Push in sides at bottom
tabs and pull outward to
release
In multi-dimmer installations, the reduction of the dimmer’s capacity may
be required. Refer to the chart for maximum load per dimmer.
NOTE: No derating is required for LED or CFL bulb applications.
•
•
•
•
Lutron Tu-Wire®:
IN
The next generation of lighting control technology is here with the new
Decora® Digital Dimmer with Bluetooth® Technology. This innovative
device works using the Leviton Decora® Digital Dimmer & Timer app
that can be easily downloaded to smartphones or tablets and paired
to the Leviton Dimmer using Bluetooth® technology. Decora® Digital
Devices give users point-to-point local control to automate lighting,
bridging the gap between standard dimmers and whole-house
automation systems.
The Decora® Digital Dimmer is a powerful device – combining the best
of Leviton dimmer and timer functions with today’s mobile technology
for impressive results. The simple touch of a finger following the
intuitive on-screen guide makes it more convenient than ever to
manage lighting for home activities or to ensure a "lived-in" look while
away. Plus, the Decora® Digital Dimmer is Universal and compatible
with LED, CFL, Incandescent, Halogen or Mark 10® Powerline loads.
Use of the app allows greater flexibility for accurate timer functionality
and makes pushing buttons for timed events a tedious chore of the
past.
The Leviton Decora® Digital Dimmer & Timer app can be easily
downloaded to mobile devices and is compatible with Android and iOS
smartphones or tablets. The app is easy to use with simple, intuitive
on-screen menu options to independently control dimmers and
switches throughout the home.
Decora® Digital Devices are ideal for living rooms, bedrooms, kitchens,
dining rooms, home offices, outdoor lighting or anywhere full control of
lighting is desired.
MULTI-DEVICE APPLICATION
INTRODUCTION
DI-000-DDMX1-02A-X3
WARNINGS AND CAUTIONS:
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Dimmer may feel warm to the touch during normal operation.
• When magnetic low voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible transformer failure due to
overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings.
• Recommended minimum wall box depth is 2-3/4".
• Use this device WITH COPPER OR COPPER CLAD WIRE ONLY.
• Use with compatible dimmable LED, CFL bulbs, incandescent or 120V halogen fixtures only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.
• When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance
dimmer performance.
WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
• T
 O AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor- or a transformer-operated appliance.
• T
 o be installed and/or used in accordance with electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
• Use ONLY with the appropriate Advance Transformer 120V Mark 10® Powerline or Lutron Tu-Wire® electronic ballasts for controlling the specific fluorescent lamps in Fluorescent Mode.
• Use with magnetic low voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low voltage dimmer to control electronic (solid state) low voltage transformers.
• When retrofitting Mark 10® Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper dimmer
operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.
• The Decora® DDMX1 dimmer is not compatible with standard 3-way or 4-way switches. It must be used with the Decora® Digital DD00R-DL remote for multi-location dimming.
BK
Green
Ground
Line
120VAC, 60Hz
YL/RD
Green
Ground
Yellow/
Red
Red
White
Black
Load
White
Black
Hot (Black)
White
Green
Ground
Line
120 VAC,
60Hz
White
Neutral (White)
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
WARNING: CONNECT A MAGNETIC LOW-VOLTAGE DIMMER ONLY
TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC
LOW-VOLTAGE TRANSFORMER.
NOTE: The DDMX1 dimmer requires a neutral wire connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Line Hot wall box wire to Black dimmer lead.
• Load wall box wire to Red dimmer lead.
• Line Neutral wall box wire to White dimmer lead.
• Yellow/Red dimmer lead should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use
electrical tape to cover.
• Proceed to Step 5.
Neutral (White)
WIRING MATCHING REMOTE (wall box with line hot
connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The matching remote must be installed in a wall box with a
Line Hot connection and a Neutral connection. A Neutral wire to the
matching remote needs to be added as shown.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft (90 m).
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to Remote terminal marked "BK".
• Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote
must go to Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The DDMX1 dimmer must be installed in a wall box that has a
Load connection and a Neutral connection.
• Green or bare copper wire in wall box to Green dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
Red dimmer lead.
• First Traveler Line Hot to Black dimmer lead.
• Remove Red insulating label from Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to
Yellow/Red dimmer lead. This traveler from the dimmer must go to
the terminal screw on the remote marked "YL/RD".
• Line neutral wall box wire to White dimmer lead.
• Proceed to Step 5.
TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Step 7 Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
NOTE: To pair your dimmer with your mobile device, download the
Leviton Decora® Digital Dimmer and Timer app from the Google Play
Store or your iTunes account. Contact Leviton’s Techline at 1-800824-3005 or visit Leviton’s website at www.leviton.com for additional
information.
100%
0%
97%
5%
95%
8%
90%
11%
85%
14%
80%
17%
75%
20%
Gently pull out
from bottom
Definition of A Modes
Load Type Selection
A-1)	
Energy Save: Sets the maximum brightness level for energy
A-2)	
savings.
A-3) Minimum Brightness Level: Sets the minimum dimming level.
Preset ON Level: Sets the turn on brightness level regardless of
A-4)	
the previous set light level.
Definition of B Modes
ON Fade Rate: Sets the amount of time in seconds it takes the
B-1)	
lights to turn ON to maximum brightness.
OFF Fade Rate: Sets the amount of time in seconds it takes the
B-2)	
lights to turn OFF from maximum brightness.
LED Options: Sets the time period in seconds the Locator LED
B-3)	
and Brightness display will stay on before extinguishing.
Definition of LEDs
Bottom LED = LED 1
Top LED = LED 7
NOTES:
• The device will exit programming
mode after 3 minutes of inactivity.
• Pressing the TOP of the Rocker at
any time during programming will
advance the device to the next
programming mode.
LED 7
Dim/
Bright
Bar
LED 1
Program Mode A
Locator LED
FADE RATE CHART
LED
Fade ON
Fade OFF
0 seconds (instant)
0 seconds (instant)
0.5 seconds
0.5 seconds
1.5 seconds
1.5 seconds
3 seconds
3 seconds
6 seconds
6 seconds
10 seconds
10 seconds
25 seconds
25 seconds
LI
To enter Program Mode A:
Press and hold the TOP of the Rocker and the TOP of the DIM/BRIGHT
FACTORY DEFAULT
Bar simultaneously for 5 seconds until the Locator LED begins to blink.
A-1) Upon releasing the TOP of the Rocker and the TOP of the DIM/
If your dimmer is not responding, or you are unable to control it after
BRIGHT Bar, the Locator LED will continue to blink once per
you have tried to Pair/Connect to it multiple times, it may be necessary
second to display the device is in Program Mode A-1, Load Type
to reset the dimmer to its original factory settings. To accomplish this,
Selection. The bottom LED will illuminate to display that the Load
proceed as follows:
Type selected is Incandescent/MLV load (default load type). To
On the dimmer, hold the TOP of the rocker until the locator LED starts
change the load type, use the DIM/BRIGHT Bar to change the
to blink. The dimmer is now reset. Once the dimmer is reset, it may be
corresponding LED to the desired load type according to the Load
necessary to re-pair with the your application.
Type Chart below. By tapping the TOP of the Rocker, this setting
will automatically be saved and the device will advance to the next
LED Brightness
OPERATION
Programming Mode, A-2, Energy Save (Maximum Brightness
Display
Level).
DIM/BRIGHT
NOTE: The locator light will illuminate when
Bar
the load is in the OFF position to facilitate
LOAD TYPE CHART
access in the dark.
NOTE: If using the dimmer in a 3-way
When indicator is at LED #
Selected Load Type is
application, the lights will turn ON at
brightness set on dimmer’s DIM/BRIGHT bar.
Incandescent/MLV
The lighting can be controlled from either the
LED
dimmer, the remote location or the mobile
device app.
CFL
Push Pad (Default settings)
Mark 10®
Turn ON from OFF position:
Tap TOP of Rocker: Lights turn ON to preset
level.
A-2) Energy Save (Maximum Brightness Level): NOTE - Energy Save
Mode can only be used with an incandescent or magnetic low voltage
Turn OFF from ON position:
Rocker
Locator
load. The Locator LED will blink 2 times per second to indicate the
Tap BOTTOM of Rocker. Lights turn OFF.
Light
device is in Program Mode A-2, Energy Save (Maximum Brightness
DIM/BRIGHT Bar
Level).The default Energy Save Mode is 100% i.e. full bright. To
BRIGHTEN:
change the Energy Save level, use the DIM/BRIGHT Bar to move
Press the TOP half of the DIM/BRIGHT Bar – Lights brighten to desired
the corresponding LED to the desired discreet preset level according
level.
to the Energy Save Chart. By tapping the TOP of the Rocker this
DIM:
setting will automatically be saved and the device will advance to the
Press the BOTTOM half of the DIM/BRIGHT Bar – Lights dim to desired
next Programming Mode, A-3, Minimum Brightness Level.
level. If you continue to hold, the lights will DIM to minimum level and
then turn OFF.
NOTE: When lights are OFF you can change the light level that the
lights will turn ON to using the DIM/BRIGHT Bar. If there is a power
outage, when the power is restored, the lights will return to the last
setting before the power interruption.
A-3) The Locator LED will blink 3 times per second to indicate the device is in
Program Mode A-3, Minimum Brightness Level. The default Minimum
Brightness Level is LED 2. To change the Minimum Brightness Level
from 1-50%, use the DIM/BRIGHT Bar. The light output will reflect the
minimum brightness level selected. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to the
next programming mode, A-4, Preset ON Level.
A-4) The Locator LED will blink 4 times per second to indicate Program
Mode A-4, Preset ON Level. To change the current Preset ON
Level from 1-100%, use the DIM/BRIGHT Bar. If this feature is not
desired, press and hold the BOTTOM half of the DIM/BRIGHT Bar
until no LED is lit (default setting). By tapping the TOP of the Rocker
this setting will automatically be saved and the device will exit
Programming Mode A.
Program Mode B
To enter Program Mode B:
Press and hold the TOP of the Rocker and then the BOTTOM of the DIM/
BRIGHT Bar for 5 seconds until the Locator LED and the TOP LED (LED 7)
begin to blink.
B-1) Upon releasing the TOP of the Rocker and the BOTTOM of the DIM/
BRIGHT Bar, the Locator LED will continue to blink once per second
indicating the dimmer is in Program Mode B-1, ON Fade Rate. To
change the ON Fade Rate, use the DIM/BRIGHT Bar to move the
LED to the desired preset level according to the Fade Rate Chart. By
tapping the Top of the Rocker this setting will automatically be saved
and the device will advance to the next programming mode, B-2, OFF
Fade Rate.
B-2) The Locator LED will blink 2 times per second to indicate Program
Mode B-2, OFF Fade Rate. To change the OFF Fade Rate, use
the DIM/BRIGHT Bar to move the LED to the desired preset level
according to the Fade Rate Chart. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to
the next programming mode, B-3 LED Options.
Download the Leviton Decora Digital Dimmer & Timer App for
your device.
Android:	Tap the Google Play Store icon on your phone or go to
http://play.google.com on your computer and follow the
instructions to obtain the app.
®
iPhone:	
Tap the App Store icon on your phone or access the app
through your iTunes account on your computer.
Once you have downloaded the app, follow the instructions on the screen
to pair your mobile device with your dimmer. Once your mobile device is
paired, use the following options to control your dimmer:
• On - Off: Turns the dimmer ON and OFF.
• Schedule: Creates distinct ON/OFF events based on time and day.
• Sleep Timer: Sets countdown to turn dimmer OFF.
Advanced Settings
Device Options
•	Randomized Scheduled Events: Cycles lights ON and OFF to
ensure a "lived-in" look while away.
• Hide LED Dim Bar: Turns LED Dim Bar OFF.
• Hide Status LED: Turns Status LED OFF.
• DST Offset Hours: Adjusts the Sunrise/Sunset time in hours.
• DST Offset Minutes: Adjusts the Sunrise/Sunset time in minutes.
Bulb Options
• Load Type: Sets load type to Incandescent/Magnetic Low-Voltage,
LED, CFL or Mark 10®.
• Fade On: Sets the amount of time for the lights to turn ON to 		
maximum brightness.
• Fade Off: Sets the amount of time for the lights to turn to OFF from
maximum brightness.
Lighting Options
• Preset: Sets the brightness level at which the lights turn ON.
• Minimum: Sets a minimum brightness level for lighting.
• Maximum: Sets a maximum brightness level for lighting.
Step 6 Dimmer Mounting:
Light output is at
Energy consumption
savings amount to
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
ADVANCED PROGRAMMING FEATURES
• Restore power at circuit breaker or fuse.
• Press pad until locator light is OFF. Lights
should turn ON. If lights do not turn ON,
press the TOP half of the DIM/BRIGHT
Bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
When indicator is at
LED #
• Position all wires to provide room
in outlet wall box for device.
• Ensure that the word “TOP” is
facing up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when mounting device.
CONTROLLING YOUR DIMMER WITH BLUETOOTH®
ENERGY SAVE CHART
IN
NOTE: If using in a dimmable fluorescent application see
Advanced Programming Feature A-1 prior to testing the device.
Air-Gap Switch: On the dimmer only, engage
the air-gap switch by gently pulling out from the
bottom of the DIM/BRIGHT bar until the bottom
of the bar lifts completely out of the frame and a
click is heard (refer to Figure). LED's will turn
OFF. This will stop power to the fixture to replace
the bulb. After servicing is complete, press the
DIM/BRIGHT Bar back into place for normal
operation.
Step 5 Testing your Dimmer prior to mounting in
wall box:
B-3) The Locator LED will blink 3 times per second to indicate Program
Mode B-3, LED Options. To change the LED Options settings, use
the DIM/BRIGHT Bar to move the LED to the desired preset setting
according to the LED Options Chart. By tapping the Top of the
Rocker this setting will automatically be saved and the device will exit
Programming Mode B.
LED OPTIONS CHART
LED
Locator LED Timeout
LED Brightness Display Options
Active
Active
Active
Turns OFF 5 seconds after use
Turns OFF 5 seconds after use
Active
Turns OFF 5 seconds after use
Turns OFF 5 seconds after use
N/A
N/A
N/A
N/A
N/A
N/A
TROUBLESHOOTING
• Lights Flickering
- Lamp has a bad connection.
-	Wires not secured firmly with wire connectors of dimmer or
terminal screws of remote.
-	
If using in a dimmable fluorescent application see Advanced
Programming Feature A-1.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Neutral not wired to Dimmer (White wire).
-	Confirm that the device is being supplied from a 120V, 60 Hz AC
source ONLY.
•		Intermittent dimmer operation
-	Confirm that the Load being controlled does not exceed the
1000VA dimmer limit.
•		Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
- Ensure wiring is correct.
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
This product is covered by U.S. Patent No. 8,664,886 and corresponding
foreign patents.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a
Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF
and ON, the user is encouraged to try to correct the interference by one or
more of the following measures:
•
Reorient or relocate the receiving Antenna.
•
Increase the separation between the equipment and the receiver.
•	Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton
Manufacturing Co., Inc., could void the user's authority to operate the
equipment.
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired
operation of the device.
Copyright and Trademark Information
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc., used under license by Leviton.
Use herein of third party trademarks, service marks, trade names, brand
names and/or product names are for informational purposes only, are/may
be the trademarks of their respective owners; such use is not meant to imply
affiliation, sponsorship, or endorsement.
No part of this document may be reproduced, transmitted or transcribed
without the express written permission of Leviton Manufacturing Co., Inc.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada
should contact Leviton in writing at Leviton Manufacturing of Canada
Ltd to the attention of the Quality Assurance Department, 165
Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by
telephone at 1-800-405-5320.
© 2015 Leviton Mfg. Co., Inc.
DI-000-DDMX1-02A-X3
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details
visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating
conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose,
is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
ARTWORK PRINT SPECIFICATIONS
DI-000-DDMX1-02A-X3
REV
DESCRIPTION
SPECIFICATIONS :
Color s :
1:
40 lb.
over
Black
3:
Finish:
For manuals - designates cover specifications
3:
Die Line Key:
Die Cut
MANUAL INTERIORS / BINDERY / FOLD SCHEME :
Body Material:
Perforate
4:
Fold Line
Kiss Cut
Cellophane
over
1:
1:
Bindery
Spot
2:
X Fold
Die cut
Drill
Perfect Bind
Trim
2:
3:
3:
Saddle Stitch
Glue
Fonts:
IN
Color s :
Thickness:
Helvetica
2:
CMYK
4:
1:
X Spot
2:
Material:
Fonts:
Thickness:
Instruction sheet
PART NUMBER
CMYK
4:
4:
DIMENSIONS / FOLD SCHEME / BINDERY DIAGRAM
PROCESS :
Flexo
Other
17"
X Offset
4.25"
Part No.
2.75"
Part No.
FINAL
11"
Line Screen:
LI
Angle:
Resolution:
Die Cut
Punch/Drill Hole
Fold Line
COMMENTS :
The information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY, INC. It is disclosed
with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict
confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any purpose other than that for which disclosed.
FOR LEVITON USE ONLY
Approvals:
PN-ARN:
Artist:
Plant
08
J. Tang
CQA
PM
B. Grande
Mktg
Eng
K. Cohen
S&A
F. Tse
Cust
Other
V. LoNigro
Other
C. Buttitta
HD0085-4848
D. Hunt
Notes:
ECR Number:
Released Artwork Format:
Pilot Rev:
Production PDF
Artwork Release Date:
RS0263-4912 - French completed under this Art Request number.
Artwork Print Specification Sheet Rev A11.eps

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Has XFA                         : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Create Date                     : 2015:12:07 13:57:14-05:00
Metadata Date                   : 2015:12:07 13:57:46-05:00
Modify Date                     : 2015:12:07 13:57:46-05:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Instance ID                     : uuid:17a24564-a74a-2840-ad2c-8b5c03f24d02
Original Document ID            : adobe:docid:indd:d29665ef-cbee-11dc-a91a-ced8fea4938b
Document ID                     : xmp.id:88c3d46d-7dc8-457d-989a-7c0b110eb972
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:c2d18a0c-f92e-425b-8d0e-1f663da1f03c
Derived From Document ID        : xmp.did:c805b8d0-a00b-4de0-a54d-f0c44b90e01f
Derived From Original Document ID: adobe:docid:indd:d29665ef-cbee-11dc-a91a-ced8fea4938b
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2015:12:07 13:57:14-05:00
Format                          : application/pdf
Title                           : DI-000-DDMX1-02A-X3.indd
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
GTS PDFX Version                : PDF/X-1a:2003
GTS PDFX Conformance            : PDF/X-1a:2003
Page Count                      : 3
Creator                         : Adobe InDesign CC 2015 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QGH-DDMX1

Navigation menu