Lodar 103 103-16 User Manual

Lodar LTD 103-16 TI 103RX 01E

a href="https://usermanual.wiki/Lodar" itemprop="url"> Lodar >

Contents

User Instructions

2or Disconnect BatteryIDENTIFY POWERCONNECTION POINTAND ISOLATE SUPPLYFuseRemove fuseVehicle  batteries  contain  gasses which are flammable and explosive. Wear eye protection and do not lean over battery while disconnecting. Do not wear metal jewellery.!WARNINGTI-103RX.01E1.     The Receiver is designed to carry a maximum of 15 Amps. That is, for example,15 Amps   through one output or 5 Amps  each through 3 outputs.2.   Master Output. This can be configured to Continuous or Parallel operation, see below right  for  more details.3.   If Receiver outputs are connected in parallel with an external switching device (wired remote)   the Receiver will instantly  switch off when the wired remote is operated4.   Lodar Receivers  have an isolation switch for safety, to allow for registering a  MUST replacement Transmitter.5.   Safety Feature. Both the Transmitter and the Receiver will “time out” after 30 minutes of   inactivity. This can be altered, ask your dealer.1!BEFORE YOU STARTWiring Instructions for TI-103 Series 1 to 16 Function, FET Receivers.3Secure using 5mm (3/16") bolts (not supplied)through the 4 mounting feetTAKE TIME TO LOCATE THE BEST POSITIONIf necessary, power the Receiver and move it aroundthe vehicle until the required performance is achieved.Operate the Transmitter and observe the Receiverinternal LED’s.Mount as HIGH as possibleAVOID surfaces with HEAVY VIBRATIONAVOID DIRECT SPRAY from wheelsIn a HOT CLIMATE fit in a SHADED positionCable gland should face DOWN or BACKReceiver 92 20 RX and 93 20 RX shown,CAUTIONMOUNT RECEIVER!What is the MASTER Output for ?It is used to operate the pump of an electro-hydraulic power pack or maybe a clutch pump. It can also be used for powering a dump valve, master valve etc. It can be configured to work continuously, that is ON when SET is pressed and OFF when STOP is pressed; or in parallel with any output, that is, it isactive only a function is operated. If it is needed with certain functions only, this can easily be configured.CONNECTION DETAIL5OPTIONAL AERIAL CONNECTIONENSURE THAT THE GAUGE OF WIRE USED CAN CARRY 15 AMPS (THIS IS THE MAXIMUM TOTAL CURRENT THAT LODAR CAN SWITCH)OVER THE DISTANCE FROM THE BATTERY WITH NO SIGNIFICANT VOLTS DROP!IMPORTANTThe Receiver switches itself offafter 30 minutes of inactivity.SAFETY FEATURE!NOTEThe STOP input can be used for OVERLOAD or OVER-TEMPERATUREetc. If the chassis isGROUND, then a returnwire is not required.!!IMPORTANT TAKE CARE NOT TO SHORT OUT THE MOSFET’s WHEN MAKING CONNECTIONS4
Download:
Mirror Download [FCC.gov]
Document ID2383486
Application IDLj3TCoaSqXES00a92mDrNA==
Document DescriptionUser Instructions
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize179.29kB (2241081 bits)
Date Submitted2014-09-10 00:00:00
Date Available2014-09-10 00:00:00
Creation Date2014-07-29 14:12:10
Producing SoftwareCorel PDF Engine Version 16.4.1.1281
Document Lastmod2014-07-29 14:12:10
Document TitleTI-103RX.01E.cdr
Document CreatorCorelDRAW X6
Document Author: Martin
FCC ID Filing: M2H103

Navigation menu