MSA Innovation 10083876 Digital Spread Spectrum Transmitter User Manual

Mine Safety Appliances Company Digital Spread Spectrum Transmitter 496958

a href="https://usermanual.wiki/MSA-Innovation" itemprop="url"> MSA Innovation >

user manual

FireHawk™ M7Air MaskNFPA 1981: 2007 EditionNFPA 1982: 2007 EditionCBRN Agent Approved Air MaskOPERATION AND INSTRUCTIONSThis device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:(1) This device may not cause harmful interference and (2) this device must accept any interference that may causeundesired operation.TAL 708 (L) Rev. 1 © MSA 2007 Prnt. Spec. 10000005389(A) Mat. 10082858Doc. 10082858This manual must be carefully read and followed by all persons who have or will have the responsibility for usingor servicing this air mask. This air mask will perform as designed only if used and serviced according to the instruc-tions; otherwise it could fail to perform as designed, and persons who rely on the air mask could sustain seriouspersonal injury or death.This Self-Contained Breathing Apparatus (SCBA) is certified by the National Institute of Occupational Safety and Health(NIOSH).Changes and modifications not expressly approved by the manufacturer could void the user’s authority to operate theequipment.Use in conjunction with personal protective ensembles that provide appropriate levels of protection against der-mal hazards.Some CBRN agents may not present immediate effects from exposure, but can result in delayed impairment, ill-ness, or death.Direct contact with CBRN agents requires proper handling of the SCBA after each use and between multiple entriesduring the same use. Decontamination and disposal procedures must be followed. If contaminated with liquidchemical warfare agents, dispose of the SCBA after decontamination.The respirator should not be used beyond 6 hours after initial exposure to chemical warfare agents to avoid possi-bility of agent permeation.FAILURE TO FOLLOW THE ABOVE ITEMS IN ADDITION TO ALL ESTABLISHED CBRN PROTECTIVE MEASURES CANRESULT IN SERIOUS PERSONAL INJURY OR DEATH.DANGERThe warranties made by MSA with respect to the product are voided if the product is not installed, used and serviced inaccordance with the instructions in this manual. Please protect yourself and your employees by following the instructions.Please read and observe the WARNINGS and CAUTIONS inside. For any additional information relative to use or repair,write or call 1-800-MSA-2222 during regular working hours.
INTRODUCTIONNIOSH APPROVAL INFORMATIONCAUTIONS AND LIMITATIONSI- Contains electrical parts which have not been evaluat-ed as an ignition source in flammable or explosiveatmospheres by MSHA/NIOSH.J- Failure to properly use and maintain this product couldresult in injury or death.M- All approved respirators shall be selected, fitted, usedand maintained in accordance with MSHA, OSHA andother applicable regulations.N- Never substitute, modify, add or omit parts. Use onlyexact replacement parts in the configuration as speci-fied by the manufacturer.O- Refer to Users Instructions, and/or maintenance man-uals for information on use and maintenance of theserespirators.S- Special or critical User’s Instructions and/or specificuse limitations apply. Refer to user instructions beforedonning.CAUTIONS AND LIMITATIONS OF USE FOR CBRNSCBAQ- Use in conjunction with personal protective ensemblesthat provide levels of protection against dermal haz-ards.R- Some CBRN agents may not present immediateeffects from exposure, but can result in delayedimpairment, illness, or death.T- Direct contact with CBRN agents requires proper han-dling of the SCBA after each use and between multi-ple entries during the same use. Decontaminationand disposal procedures must be followed. If conta-minated with liquid chemical warfare agents, disposeof the SCBA after decontamination.U- The respirator should not be used beyond 6 hoursafter initial exposure to chemical warfare agents toavoid possibility of agent permeation.S - SPECIAL OR CRITICAL USER’S INSTRUCTIONSApproved for use at temperatures above -25°F. Approvedonly when the compressed-air container is fully chargedwith air meeting the requirements of the Compressed GasAssociation Specification G-7 for quality verification level(grade) D air or equivalent specifications. In fire serviceapplications, MSA recommends breathing air quality inaccordance with NFPA 1989. The cylinder shall meetapplicable DOT specifications.Do not alter this air mask. Altering will void the Intrinsic-Safety rating and may affect the Intrinsic-Safety of thedevice. Misuse or abuse of the heads-up display system(FireHawk M7 HUD), FireHawk M7 Control Module, orFireHawk M7 Power Module or using this equipment in amanner or situation not intended by the manufacturer, mayresult in damage to the FireHawk M7 HUD, FireHawk M7Control Module, or FireHawk M7 Power Module, mayresult in personal injury or death to user or persons depen-dent on the user. Always inspect the FireHawk M7 HUD fordamage before use. If damage is found, immediatelyremove the device from service. The FireHawk M7 HUD,FireHawk M7 Control Module, and FireHawk M7 PowerModule are approved intrinsically-safe and conform toUL/ANSI 913 for use in Class I, Div. I, Groups C and Dhazardous locations, temperature rating T3.Use the air mask with adequate skin protection whenworn in gases and vapors that poison by skin absorption(for example: hydrocyanic-acid gas). In making renewalsor repairs, parts identical with those furnished by themanufacturer under the pertinent approval shall be main-tained.Approval for use against CBRN chemical warfare agentsis maintained only when using approved components andfollowing instructions listed on the NIOSH approval matrix(P/N 10083874)Do not mark the air mask, i.e., with stamps, labels, paint,or other method. Use of such markings may interfere withapparatus use or may constitute a flammability hazard.2TAL 708 (L) Rev. 1 - 10082858TABLE OF CONTENTSNIOSHApprovalInformation .........................................................................2SpecialorCriticalUsersInstructions ...................................................................2Description .......................................................................................5InspectionandFunctionalTests .......................................................................9Donning.........................................................................................13UsingtheAirMask ................................................................................17ColdWeatherOperation ............................................................................25URCAssemblyOperation...........................................................................27RemovingtheApparatus ...........................................................................29CleaningandDisinfecting ...........................................................................33FlowTestandOverhaulRequirements.................................................................35Quick-FillSystemOperation.........................................................................37ExtendAireSystem ................................................................................41Appendix........................................................................................43
Download:
Mirror Download [FCC.gov]
Document ID862274
Application IDRjEYdTj/VEEEDbOFEQpaYw==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize53.15kB (664349 bits)
Date Submitted2007-10-31 00:00:00
Date Available2007-11-06 00:00:00
Creation Date2007-09-13 08:05:52
Producing SoftwareQuarkXPress(R) 7.01
Document Lastmod2007-09-13 08:07:54
Document Title496958
Document CreatorQuarkXPress(R) 7.01
FCC ID Filing: P9R-10083876

Navigation menu