Masimo RAD87A RAD-87 User Manual LAB5230A indd

Masimo Corporation RAD-87 LAB5230A indd

Contents

User Manual Addendum

Download: Masimo RAD87A RAD-87 User Manual LAB5230A indd
Mirror Download [FCC.gov]Masimo RAD87A RAD-87 User Manual LAB5230A indd
Document ID1006234
Application ID/IBmm0fz2KuODKQ6A5tyfA==
Document DescriptionUser Manual Addendum
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize9.16kB (114473 bits)
Date Submitted2008-09-24 00:00:00
Date Available2008-09-24 00:00:00
Creation Date2008-08-12 15:51:52
Producing SoftwareAcrobat Distiller 8.0.0 (Windows)
Document Lastmod2008-08-12 15:51:52
Document TitleLAB5230A.indd
Document CreatorPScript5.dll Version 5.2
Document Author: CStraub

Rad-87
™
Pulse CO-Oximeter
Operator’s Manual
Wireless Radio Addendum
TABLE OF CONTENTS
English............................................................... 1
French (Français)................................................ 2
German (Deutsch).............................................. 3
Italian (Italian)..................................................... 4
Spanish (Español).............................................. 5
English
Rad-87 Operator’s Manual Wireless Radio Addendum
This addendum describes wireless radio licensing and specification information for the
Rad-87 Pulse CO-Oximeter. This addendum is used in conjunction with revision E of the
Rad-87 Operator’s Manual, part number 31374.
PAGE i
FCC ID: VKF-RAD87A
IC ID: 7362A-RAD87A
PAGE iii
■ This equipment has been tested and found to comply with the limits for medical devices to
the EN 60601-1-2, Medical Device Directive 93/42/EEC and Part 15, FCC Rules/USA.
■ This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
SECTION 7: SPECIFICATIONS
Wireless Radio Specifications (if installed)
Radio Modes
Encryption
Authentication
8802.11 a/b/g
64/128-bit WEP, Dynamic WEP, WPA-TKIP, WPA2-AES
Open System, Shared Key, Pre-Shared Key (PSK), 802.1X:
LEAP, PEAP, TTLS, TLS, EAP-FAST
Compliance
USA
FCC ID VKF-RAD87A
FCC parts 15.207, 15.209, 15.247 and 15.407
Canada
IC ID 7362A-RAD87A
RSS-210
Europe
EN 300 328
EN 301 893
EN 301 489-17
13
Français (French)
Addendum au manuel de l’utilisateur du Rad-87 sur la
radio sans fil
Cet addendum traite de la license de la radio sans fil et des caractéristiques du CO-oxymètre
de pouls Rad-87. Cet addendum doit être utilisé conjointement avec la révision A du manuel de
l’utilisateur du Rad-87, référence 32750.
PAGE i
FCC ID: VKF-RAD87A
IC ID: 7362A-RAD87A
PAGE iii
■ Cet équipement a été testé et déclaré conforme aux limites applicables aux
appareils médicaux établies par la norme EN 60601-1-2, la directive pour
appareils médicaux 93/42/CEE et les règles FCC/USA, Partie 15.
■ Cet appareil est conforme à la section 15 des règles de la FCC. Le fonctionnement est
sujet aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence
néfaste, et (2) cet appareil doit accepter toutes les interférences reçues, y compris les
interférences qui peuvent causer un fonctionnement non désiré.
SECTION 7: CARACTÉRISTIQUES
Caractéristiques de la radio sans fil (si installée)
Modes uniquement radio
Encryptage
Authentification
8802.11 al/b/g
64/128-bit WEP, Dynamique WEP, WPA-TKIP, WPA2-AES
Système Ouvert, Clef Partagée, Clef Pre-Partagée (PSK),
802.1X: LEAP, PEAP, TTLS, TLS, EAP-FAST
Conformité
USA
FCC ID VKF-RAD87A
FCC pièces 15.207, 15.209, 15.247 et 15.407
Canada
IC ID 7362A-RAD87A
RSS-210
Europe
EN 300 328
EN 301 893
EN 301 489-17
Deutsch (German)
Bedienungsanleitung für die Erweiterung der W-LAN
Funktion
Dieser Anhang beschreibt die W-LAN Spezifikationen des Rad-87 Co-Oximeter. Dieser Anhang
wird in Verbindung mit Neuausgabe A des Handbuches des Operators Rad-87, Teilenummer
32751 benutzt.
SEITE i
FCC ID: VKF-RAD87A
IC ID: 7362A-RAD87A
SEITE iii
■ Dieses Gerät wurde getestet und erfüllt die Grenzwerte für medizinische Geräte gemäß
EN 60601-1-2, die Richtlinie über Medizinprodukte 93/42/EWG entsprechend Teil 15 der
US-amerikanischen FCC-Vorschriften.
■ Das Gerät hält die Richtline Abschnitt 15 der FCC Verordnung ein. Während des Betriebs
des Gerätes werden zwei Voraussetzungen erfüllt (1) das Gerät verursacht keine gesundheitsschädlichen Interferenzen und (2) sonstige Interferenzen werden empfangen, diese
haben aber keinen Einfluss für die Funktion des Gerätes.
ABSCHNITT 7: SPEZIFIKATIONEN
Drahtlose Funkspezifikationen (wenn sie angebracht werden)
Funkmodi
8802.11 a/b/g
Verschlüsselung
64/128-bit WEP, Dynamisch WEP, WPA-TKIP, WPA2-AES
Authentisierung
Geöffnetes System, Geteilter Schlüssel, Pre-Geteilter Schlüssel
(PSK), 802.1X: LEAP, PEAP, TTLS, TLS, EAP-FAST
Einhaltung der
USA
FCC ID VKF-RAD87A
FCC Teile 15.207, 15.209, 15.247 und 15.407
Kanada
IC ID 7362A-RAD87A
RSS-210
Europa
EN 300 328
EN 301 893
EN 301 489-17
Italiano (Italian)
Rad-87 Operator’ addenda radiofonica senza fili manuale
Questo supplemento descrive le informazioni,le specifiche e le autorizzazioni di trasmissione
radio per l’ossimetro Rad-87. Questo supplemento viene utilizzato insieme alla revisione la A
del manuale dell’operatore Rad-87, numero del pezzo 32752.
PAGINA i
FCC ID: VKF-RAD87A
IC ID: 7362A-RAD87A
PAGINA iii
■ Questa apparecchiatura è stata sottoposta a test risultando conforme ai limiti previsti
per i dispositivi medici in base alla norma EN 60601-1-2, direttiva europea 93/42/CEE
relativa ai dispositivi medici et Parte 15, disposizioni FCC/USA.
■ Questo strumento segue le indicazioni - Parte 15- delle norme FCC (Commissione
Federale Per Le Comunicazioni). L’operazione e’ soggetta alle due seguenti indicazioni (1) Questo strumento non puo’ in nessun caso causare interferenze dannose,
inoltre (2) questo sturmento deve “accettare” ogni interferenza a cui puo’ essere sottoposto, incluse quelle interferenze che potrebbero causare operazioni indesiderate.
SEZIONE 7: SPECIFICHE
Specifiche radiofoniche senza fili (se installato)
Modi radiofonici
Crittografia
Autenticazione
8802.11 a/b/g
64/128-bit WEP, Dinamico WEP, WPA-TKIP, WPA2-AES
Sistema Aperto, Chiave Comune, Pre-Chiave Comune (PSK),
802.1X: LEAP, PEAP, TTLS, TLS, EAP-FAST
Conformità
USA
Il Canada
Europa
FCC ID VKF-RAD87A
FCC parti 15.207, 15.209, 15.247 e 15.407
IC ID 7362A-RAD87A
RSS-210
EN 300 328
EN 301 893
EN 301 489-17
Español (Spanish)
Anexo al manual de usuario del Rad 87 inalámbrico.
Esta suplemento describe la información de radio sin hilos de la autorización y de la especificación para el CO-Oxímetro del pulso Rad-87. Esta suplemento se utiliza conjuntamente con
la revisión A del manual del operador Rad-87, número de parte 32753.
PÁGINA i
FCC ID: VKF-RAD87A
IC ID: 7362A-RAD87A
PÁGINA iii
■ Este equipo fue sometido a pruebas y se determinó que cumple con los límites para
dispositivos médicos conforme a la norma EN 60601-1-2, y a la Directiva 93/42/EEC
relativa a los dispositivos médicos y con la Parte 15 de las reglas de la FCC (Comisión
Federal de Comunicaciones) de Estados Unidos.
■ Este dispositivo cumple con el Reglamento FCC. parte 15. Su funcionamiento está
sujeto a las siguientes dos condiciones: (1) Este dispositivo no puede causar interferencias perjudiciales y (2) este dispositivo debe aceptar cualquier interferencia recibida, incluidas interferencias que puedan causar un funcionamiento no deseado.
SECCIÓN 7: ESPECIFICACIONES
Especificaciones de radio sin hilos (si están instaladas)
Modos de radio
8802.11 a/b/g
Encripción
64/128-bit WEP, Dinámico WEP, WPA-TKIP, WPA2-AES
Autentificación
Sistema Abierto, Llave Compartida, Pre-Llave Compartida
(PSK), 802.1X: LEAP, PEAP, TTLS, TLS, EAP-FAST
Conformidad
USA
FCC ID VKF-RAD87A
FCC piezas 15.207, 15.209, 15.247 y 15.407
Canadá
IC ID 7362A-RAD87A
RSS-210
Europa
EN 300 328
EN 301 893
EN 301 489-17
EU Authorized Representative for Masimo
Corporation:
EC
Masimo Corporation
40 Parker
Irvine, CA 92618
USA
www.masimo.com
© 2008 Masimo Corporation.
REP
MDSS GmbH
Schiffgraben 41
30175 Hannover, Germany
Tel.: +49-511-62 62 86 30
Fax.: +49-511-62 62 86 33
33077/5230A - 0808 E-LAB4525E
Manufacturer:

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Format                          : application/pdf
Creator                         : CStraub
Title                           : LAB5230A.indd
Create Date                     : 2008:08:12 15:51:52-07:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2008:08:12 15:51:52-07:00
Producer                        : Acrobat Distiller 8.0.0 (Windows)
Document ID                     : uuid:8fb3214e-0b90-4f8e-85d3-ab62f4a99131
Instance ID                     : uuid:b59f84da-5ab7-43f2-a172-f348c7c78c24
Page Count                      : 8
Author                          : CStraub
EXIF Metadata provided by EXIF.tools
FCC ID Filing: VKF-RAD87A

Navigation menu