Operating Manual MHX-2400 2.4 GHz Spread Spectrum OEM Transceiver Revision 1.11, December 1, 2000 Microhard Systems Inc. #110, 1144 - 29th Ave. N.E. Calgary, Alberta T2E 7P1 Phone: (403) 248-0028 Fax: (403) 248-2762 www.microhardcorp.com MHX-2400 2.4 GHz Spread-Spectrum Embedded Modem WARNING In order to comply with the FCC/IC adopted RF exposure requirements, this transmitter system will be installed by the manufacturer's reseller professional. Installation of all antennas must be performed in a manner that will provide at least 20 cm clearance from the front radiating aperture, to any user or member of the public. This manual contains information of proprietary interest to Microhard Systems Inc. It has been supplied in confidence to purchasers and users of the MHX-2400, and by accepting this material the recipient agrees that the contents will not be copied or reproduced, in whole or in part, without prior written consent of Microhard Systems Inc. Microhard Systems Inc. has made every effort to assure that this document is accurate and complete. However, the company reserves the right to make changes or enhancements to the manual and/or the product described herein at any time and without notice. Furthermore, Microhard Systems Inc. assumes no liability resulting from any omissions in this document, or out of the application or use of the device described herein. Microhard Systems’ products are appropriate for home, office, or industrial use, but are not authorized for utilization in applications where failure could result in damage to property or human injury or loss of life. The electronic equipment described in this manual generates, uses, and radiates radio frequency energy. Operation of this equipment in a residential area may cause radio interference, in which case the user, at his own expense, will be required to take whatever measures necessary to correct the interference. FCC Declaration of Conformity This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may caused undesired operation. Microhard Systems Inc.’s products are warranted against all failures which occur as a result of defective material or workmanship within 12 months of purchase by the user. This warranty does not extend to products that, in the opinion of Microhard Systems Inc., have been subject to misuse, accidents, lightning strikes, improper installation or application, nor shall it extend to units which have, in Microhard Systems Inc.’s opinion, been opened, tampered with or repaired by an unauthorized facility. Microhard Systems Inc. Leaders in Wireless Telecom th #110, 1144 - 29 Ave. N.E. Calgary, Alberta T2E 7P1 Phone: (403) 248-0028 Fax: (403) 248-2762 www.microhardcorp.com ii © 2000 by Microhard Systems Inc., All Rights Reserved. HyperTerminal is copyrighted by Hilgraeve Inc, and developed for Microsoft. Microsoft and Windows are registered trademarks of Microsoft Corporation. pcANYWHERE and Symantec are registered trademarks of Symantec Corp. All other products mentioned in this document are trademarks or registered trademarks of their respective holders. Manual Revision 1.11, December 1, 2000. MHX-2400 Operating Manual Contents 1. 2. 3. A. B. C. D. F. G. H. Introduction 1.0 Product Overview .............................................................................................................................................................................. 1 1.1 Features.............................................................................................................................................................................................. 1 1.2 About this Manual ............................................................................................................................................................................. 2 Initial Setup and Configuration 2.0 Unpacking and Inspection ................................................................................................................................................................. 3 2.1 Additional Requirements ................................................................................................................................................................... 3 2.2 Connectors and Indicators.................................................................................................................................................................. 3 2.3 Configuration..................................................................................................................................................................................... 6 2.4 Checking the Link............................................................................................................................................................................... 6 Configuration Options 3.0 Command Line Interface.................................................................................................................................................................... 9 3.1 AT Commands................................................................................................................................................................................. 10 A - Answer........................................................................................................................................................................................ 10 E - Command Echo.......................................................................................................................................................................... 10 I - Identification ............................................................................................................................................................................... 10 O - Online Mode .............................................................................................................................................................................. 11 Q - Quiet Mode................................................................................................................................................................................ 11 V - Result Codes Display................................................................................................................................................................. 11 W - Connection Result..................................................................................................................................................................... 11 Z - Reset Modem and load stored configuration .............................................................................................................................. 11 &C - DCD (Data Carrier Detect) ..................................................................................................................................................... 11 &D - DTR (Data Terminal Ready)................................................................................................................................................... 11 &F - Load Factory default configuration ......................................................................................................................................... 12 &K - Handshaking ............................................................................................................................................................................ 12 &S - DSR (Data Set Ready)............................................................................................................................................................. 12 &V - View Configuration ................................................................................................................................................................. 12 &E - Framing Error Check................................................................................................................................................................ 12 &W - Write Configuration to memory ............................................................................................................................................. 12 Sxxx? - Read S register value........................................................................................................................................................... 12 Sxxx=yyy - Set S register value ....................................................................................................................................................... 12 3.2 Command Result Codes................................................................................................................................................................... 13 3.3 S Registers ....................................................................................................................................................................................... 14 S Register 2 - Escape Code ............................................................................................................................................................... 14 S Register 3 - CR Control Code....................................................................................................................................................... 14 S Register 4 - Linefeed Control Code .............................................................................................................................................. 14 S Register 5 - Backspace Control Code ........................................................................................................................................... 14 S Register 101 - Operating Mode..................................................................................................................................................... 15 S Register 102 - Serial Baud Rate.................................................................................................................................................... 17 S Register 103 - Wireless Link Rate ................................................................................................................................................ 17 S Register 104 - Network Address ................................................................................................................................................... 18 S Register 105 - Unit Address.......................................................................................................................................................... 18 S Registers 106 and 206 - Primary and Secondary Hopping Patterns.............................................................................................. 18 S Register 107 - Encryption Key...................................................................................................................................................... 20 S Register 108 - Output Power Level............................................................................................................................................... 20 S Register 109 - Hopping Interval.................................................................................................................................................... 21 S Register 110 - Data Format............................................................................................................................................................ 21 S Registers 111 and 112 - Packet Minimum and Maximum Size..................................................................................................... 22 S Register 116 - Packet Character Timeout ...................................................................................................................................... 22 S Registers 113 and 213 - Packet Retransmission/Packet Retry Limit ............................................................................................. 23 S Register 115 - Packet Repeat Interval........................................................................................................................................... 24 S Register 117 - Modbus Mode ........................................................................................................................................................ 24 S Register 120 and 121- RTS/DCD Framing/Timeout ..................................................................................................................... 25 S Register 123 - RSSI Reading ......................................................................................................................................................... 25 Modem Command Summary ...................................................................................................................................................................... 26 Serial Interface ............................................................................................................................................................................................ 29 Sample Schematic Diagram ........................................................................................................................................................................ 31 Factory Default Settings.............................................................................................................................................................................. 33 Performance Tables...................................................................................................................................................................................... 34 Hopping Tables............................................................................................................................................................................................ 35 Technical Specifications ............................................................................................................................................................................. 36 Glossary ...................................................................................................................................................................................................... 38 1. Introduction 1.0 Product Overview Congratulations on choosing the MHX-2400 wireless transceiver! Your new MHX-2400 modem is a state-of-the-art, 2.4 GHz frequency-hopping spreadspectrum communications module. When the MHX-2400 module is incorporated into the design of new or existing equipment, terminal devices (DTEs) up to 30 km (or more)1 apart will be capable of establishing highspeed2 communications wirelessly. MHX-2400 modules provide a practical and reliable alternative to using traditional analog phone-line modems or “permanent wire” serial cable (RS-232) connections for data communications between asynchronous serial equipment. Moreover, wireless data communications using the MHX-2400 module means you will benefit from: n greater flexibility and freedom to relocate terminal equipment, n eliminated requirement for access to wire-based transfer media such as telephone lines, n the ability to communicate through walls, floors, and many other obstacles. While the MHX-2400 module is compact in its design, it delivers power and convenience and offers quality and dependability. The MHX-2400 module’s versatility makes it the ideal solution for applications ranging from officeproductivity to industrial data control and acquisition. While a pair of MHX-2400 modules can link two terminal devices (“point-topoint” operation), multiple MHX-2400 modules can be used together to create a network of various topologies, including “point-to-multipoint” and “repeater” operation. Multiple independent networks can operate concurrently, so it is possible for unrelated communications operations to take place in the same or a nearby area without sacrificing privacy, functionality, or reliability. 1.1 Features Key features of the MHX-2400 module include: n transmission within a public, license-exempt band of the radio spectrum3 – this means that it can be used without access fees (such as those incurred by cellular airtime); n a serial I/O data port (TTL levels) with handshaking and hardware flow control, allowing the MHX-2400 module to interface directly to any microprocessor with an asynchronous serial interface. Ideal conditions with clear line-of-sight communications, using high-gain antennas. Up to 115,200 bits per second (bps). 902-928 MHz, which is license-free within North America; may need to be factory-configured differently for some countries. MHX-2400 Operating Manual: Chapter 1 Introduction. n 49 sets of user-selectable pseudo-random hopping patterns, intelligently designed to offer the possibility of separately operating multiple networks while providing security, reliability and high tolerance to interference; n encryption key with 65536 user-selectable values to maximize security and privacy of communications; n built-in CRC-16 error detection and auto re-transmit to provide 100% accuracy and reliability of data; n ease of installation and use – the MHX-2400 module uses a subset of standard AT style commands, very similar to those used by traditional telephone line modems. While the typical application for the MHX-2400 is to provide a short- to midrange wireless communications link between DTEs, it can be adapted to almost any situation where an asynchronous serial interface is used and data intercommunication is required. 1.2 About this Manual This manual has been provided as a guide and reference for installing and using MHX-2400 wireless modem modules. The manual contains instructions, suggestions, and information which will help you set up and achieve optimal performance from your equipment using the MHX-2400 module. It is assumed that users of the MHX-2400 module have either system integration or system design experience. Chapter 2 details the requirements and connections of the MHX-2400 module. Chapter 3 describes the AT command register setup and configuration. The Appendices, including the Glossary of Terms, are provided as informational references which you may find useful throughout the use of this manual as well as during the operation of the wireless modem. Throughout the manual, you will encounter not only illustrations that further elaborate on the accompanying text, but also several symbols which you should be attentive to: Caution or Warning: Usually advises against some action which could result in undesired or detrimental consequences. Point to Remember: Highlights a key feature, point, or step which is worth noting, Keeping these in mind will make using the MHX-2400 more useful or easier to use. Tip: An idea or suggestion is provided to improve efficiency or to make something more useful. With that in mind, enjoy extending the boundaries of your communications with the MHX-2400 module. MHX-2400 Operating Manual: Chapter 1 Introduction 2. Initial Setup and Configuration 2.0 Unpacking and Inspection The following items should be found in the shipping carton. Inspect the contents for any shipping damage. Report damages or shortages to the distributor from which the unit was purchased. Keep all packing materials in the event that transportation is required in the future. Package contents (normal distribution): MHX-2400 Wireless Modem module Operating Manual (this document) 2.1 Additional Requirements Since the MHX-2400 module is a unique product in a class of its own, it will communicate only with another MHX-2400 module which has been compatibly configured. Thus, at least two MHX-2400 modules will be required to establish a wireless communications link. Additionally, the following requirements should be taken into consideration when preparing to incorporate the MHX-2400 module in new or existing designs. n Small footprint for the MHX-2400 module (e.g., 2.1” W x 3.5” L x 0.8” H) on the OEM PCB. n Serial port and control signals from the host microprocessor. See sample application schematics in Appendix C. n +5 Vdc supply from the host OEM electronics. n An external antenna (customer supplied). 2.2 Connectors and Indicators The MHX-2400 module connects to the host equipment by two single row header strips on the underside of the unit. This enables the MHX-2400 module to be directly soldered or socketed onto the host equipment manufacturer’s PCB. The pinout for the module is given in Figure 1. MHX-2400 Operating Manual: Chapter 2 Initial Setup and Configuration Top View Vcc Vcc Vcc Vcc Vcc Vcc Vcc Radio Radio Logic Logic Logic Logic Logic N/C /CONFIG /RESET GND GND GND GND GND GND GND N/C N/C N/C 40 20 21 N/C N/C N/C N/C N/C N/C N/C Rx Mode LED Tx Mode LED RSSI LED 3 RSSI LED 2 RSSI LED 1 CTS RTS DSR N/C DTR TxD RxD DCD Antenna Connector Figure 1 - Pinout Diagram IMPORTANT: For best performance, it is strongly recommended to use a separate, linearly regulated supply for Vcc Radio. Do not directly feed a switching power supply into Vcc Radio. For OEM design simplicity, connect both the radio and logic Vcc connections together. The interface connectors and indicator lights are summarized below: Vcc Radio - These pins supply power for the MHX-2400’s radio circuitry. Best performance is achieved by providing linearly regulated voltage to these pins. It is essential to keep this supply rail as clean as possible preferrably by not directly feeding a switching power supply into Vcc Radio. In addition, it is recommended that Vcc Radio be regulated as close to 5.5V as possible (without exceeding 5.5V). Running from a 5V regulator will decrease the transmitted power by roughly 1dB. The linear regulator must be rated for at least 800 mA Vcc Logic - These pins supply power for the MHX-2400’s digital circuitry. It is recommended you use a linear regulator to feed Vcc Logic. Current consumption in the logic circuitry is typically 100 mA. The regulator should be rated for at least 200 mA. To simplify the OEM design, the Radio Vcc can be connected to the Logic Vcc. GND - Ground return pins for both Radio and Logic circuitry /RESET - This momentary active low input signal (100 ms typical) resets the MHX-2400. /CONFIG - Leave this pin unconnected. Do NOT ground. Caution: Using any other power supply which does not provide the proper voltage or current could damage the MHX-2400 module. Receive Signal Strength Indicator (RSSI) - These active high TTL outputs are designed to drive LED’s. As the signal strength increases, the number of active RSSI lines increases, starting with RSSI1. When configured as a Repeater, the module does not indicate RSSI. The LED’s perform a “scanning” function, blinking on and off in sequence when a Slave or Repeater modem is searching for synchronization. The current sourcing capability of these lines is 20 mA. MHX-2400 Operating Manual: Chapter 2 Initial Setup and Configuration Data Port (DCE) - Pins 21 through 28 inclusive. This port is used to interface the MHX-2400 module to a DTE device and operates at 2400 to 115,200 bps. The levels are active low 5V logic levels, and include (See Appendix B for a complete description): Pin No. Name Description I/O 21 DCD Data Carrier Detect 22 RxD Receive Data 23 TxD Transmit Data 24 DTR Data Terminal Ready 25 NC No Connect 26 DSR Data Set Ready 27 RTS Request to Send 28 CTS Clear to Send RX Indicator - This active high output indicates the modem is receiving data packets with correct CRC, and is designed to drive a LED. When the unit is configured as a Slave, this LED will typically be on solid under good operating conditions. TX Indicator - This active high output is designed to drive a LED, and indicates the modem is transmitting. Antenna Connector - The MHX-2400 uses an end launch SMA RF connector. Microhard Systems can provide the cabling from the module to the appropriate antenna connector. A suitable antenna must be used to ensure adequate performance of the MHX-2400 module. N/C - These pins are reserved for future use. Do not connect to these pins. MHX-2400 Operating Manual: Chapter 2 Initial Setup and Configuration 2.3 Configuration Prior to establishing a wireless link, each MHX-2400 module participating in the link must be correctly configured for compatibility and for the desired mode of operation. Network 1 Network topologies consisting of a single Master and virtually any combination of Slaves and Repeaters may be deployed. The functionality of any particular MHX-2400 can be configured as follows: Network 2 Network 3 Network 4 Network 5 Figure 2 - Sample Network Topologies. Virtually any Combination of Slaves and Repeaters May be Used. n Master Point-to-Point: The module is configured to communicate with a single Slave, either directly, or through one or more Repeaters. n Master Point-to-Multipoint: The module is configured to communicate with one or more Slaves and/or Repeaters. n Slave: The module is configured to communicate with one particular Repeater or Master. n Repeater: The module is configured to pass information from either a Master or another Repeater onto subsequent Repeaters and/or Slaves and vice versa. The Repeater also acts as a Slave in the sense that, like a Slave, it passes information to/from its serial port. All units within a network must be assigned a common Network Address; thus enabling multiple networks to co-exist in the same vicinity without unwanted crosstalk between modules. Examples of different network topologies are shown in Figure 2. Network 1 shows Point-to-Point communication between a Master and Slave. Network 2 makes use of a Repeater to communicate with the Slave. Network 3 illustrates a simple Point-to-Multipoint network with no Repeaters. Networks 4 and 5 gives examples of Point-to-Multipoint networks consisting of both Repeaters and Slaves. There is effectively no restriction to the number of Repeaters and Slaves that can be added to a network. As seen in Network 4, a Master can communicate directly with both Slaves and Repeaters. The MHX-2400 has been designed to allow for additional Repeaters and Slaves to be added to an existing network without having to reconfigure any units already in the network. This saves a tremendous amount of time when deploying additional units in the field. 2.3.1 Quick Start Approach The MHX-2400 is equipped with four standard factory default settings. Instead of manually configuring each individual operating parameter, a global command may be used to quickly configure the modem for a particular type of operation. For example, to quickly implement Network 1, Factory default 1 would be applied to the Master, and Factory default 2 would be applied to the Slave. To quickly set up Network 2, apply Factory 1 to the Master, Factory 3 to the Repeater, and Factory 4 to the Slave. These defaults will get you started and only ensure that a link can be established, but do not necessarily provide the best performance. Optimization of the communications link is discussed in later sections. MHX-2400 Operating Manual: Chapter 2 Initial Setup and Configuration How to Set Up A Simple Network The MHX-2400 will always be in one of two states: n Data Mode – When in this state, the modem is listening and talking to other modems in the network (the modem is online). n Command Mode – When in this state, the modem is awaiting “AT Commands” from the serial port. These commands are used to configure all operating parameters of the modem. When in this state, the modem is “offline”. To implement the very basic network illustrated in Figure 2, Network 1, n Plug the modem into the development board and connect a straight- through serial cable between the development board and the terminal (e.g., your PC) Connect an antenna cable and antenna to the module. Configure the unit to Factory Setting 1 by typing AT&F1. This puts the unit into Master Point-to-Multipoint mode. Store these settings to memory by typing AT&W . Put the modem into Data Mode by typing ATA . There are other ways to enter Data Mode, which are discussed in Chapter 3. Perform the above steps for the second unit, using the command AT&F2 instead of AT&F1. This will configure the second unit as a Slave. The units should now be communicating. Remember, the parameters defined by AT&F1 and AT&F2 will likely not be the most ideal for your application, but will quickly allow you to test the units. A complete summary of the settings defined by AT&F1,2,3 and 4 can be found in Appendix D. Factory Default Settings. Warning: Using an antenna that is inappropriate for use with the MHX-2400 module could result in undesired performance, and may damage the unit. It is the user’s responsibility to ensure the antenna has adequate lightning protection. Settings are not immediately stored in non-volatile memory, therefore, the command &W is issued to store the current configuration into non-volatile memory. Settings are retained even after powering down. All user selectable parameters for the MHX-2400 are described in detail in Chapter 3: Configuration Options. 2.4 Checking the Link To check if the units are communicating, observe the LED indicators on the development board. If the link is good, up to three RSSI outputs on the Slave modem should be active; and if the link is absent (due to a fault at one end or another, such as misconfiguration), the outputs will be in either “scanning mode” or inactive. Characters typed at the Master terminal should appear at the Slave’s terminal, and vice versa. Also, verify that the RX LED blinks as packets of data are received at the Master modem. As data is sent from Slave to Master, the RX indicator should blink on as correct packets of data are received. It is recommended that if MHX-2400 modules will be deployed in a field where large distances separate the units, the modems should be configured and tested in close proximity (e.g., in the same room) first to ensure a good link can be established and settings are correct. This will facilitate troubleshooting, should problems arise. MHX-2400 Operating Manual: Chapter 2 Initial Setup and Configuration 3. Configuration Options 3.0 Command Line Interface The MHX-2400 modem can be easily configured to meet a wide range of needs and applications. You can have your modem perform a variety of functions by sending it instructions (in the form of commands). Sending a command overrides the modem’s operating characteristics. Your modem must be in Command Mode for it to execute a command. If you send characters when the modem is in Data Mode, the modem transmits the characters over the air. Depending on its settings, the modem will either power up in Command Mode or Data Mode. Normally, when first received from the factory, the unit will power up in Command Mode. You can place the modem into Data Mode either by 1. Issuing the answer command 2. Issuing the online command You can place the modem into Command Mode either by The escape sequence will not be accepted unless both the MHX-2400 and the terminal are set to the same baud rate 1. Sending the escape sequence 2. Toggling the DTR line (depending on the &D parameter see pg 11). To enter a command line and have your modem execute it, use the following procedure: 1. With your modem in the Command Mode, type AT. These characters, known as the attention characters, must be typed at the beginning of each command line. 2. Type the command(s). Include any parameters required by the command. To make the command line more readable, you can insert as many spaces as desired. The command line holds up to 16 characters, not including the AT prefix. 3. Press the ENTER key. Your modem executes the command line and sends you a word response (usually OK). Refer to Appendix A (page 19) for a summary of the modem commands Configuration options are not stored in non-volatile memory until the WRITE command (&W) is executed For example, to set the Operating Mode S101 register to Master Point-toMultipoint mode, enter the following command line; AT S101 = 1 . To display what a register is currently set to, enter the following command line; AT Sxxx? . The modem will output the value of the register. MHX-2400 Operating Manual: Chapter 3 Configuration Options Note: If you want to send more than one command line, wait for a response before entering the AT prefix at the start of the next command line. To re-execute the previous command, enter A/. The modem will execute the previous command line. When in Command Mode, the modem “autobauds”, meaning that it will automatically adjust to the baud rate of the terminal. You may change the terminal baud rate while in Command Mode without losing communication with the modem. For the AT command protocol, an escape sequence consists of three consecutive escape codes preceded and followed by at least 1 second of inactivity. Typically, the ‘+’ character is used as the escape code. +++ preceded and followed by 1 second of inactivity Note that the terminal must be configured to the same baud rate as the modem in order for the mode to recognize the escape sequence. The modem is unable to “autobaud” while in Data Mode. 3.1 AT Commands Several AT Commands are supported by the MHX-2400 module. The following is a short description of all available commands. ‘*’ denotes standard factory settings. All of the following commands must be preceded by “AT” Answer The A command causes the modem to attempt to connect with another remote modem (Type ATA ). Command Echo Your modem is preset to return (or echo) commands to the host microprocessor when in Command Mode. E0 *E1 No Command Echo Command Echo Identification The I command returns various modem information settings. I1 I2 I3 I4 I5 I6 I7 Product Code (MHX-2400) Issue ROM Check (OK or ERROR) Product Identification (Firmware Version) Firmware Date Firmware Copyright Firmware Time Serial Number MHX-2400 Operating Manual: Chapter 3 Configuration Options O On-line Mode The O command attempts to put the modem online and communicate with a remote modem. Quiet Mode Your modem is preset to send responses when it executes commands, and there after to keep the host informed of its status. *Q0 Q1 Enable modem responses Disable modem responses Result Codes display Your modem can either display result codes as words or numbers. V0 *V1 Display Result Codes as numbers Display Result Codes as words Connection Result The W command returns your modem to the Data Mode from the Command Mode *W0 W1 W2 Reports computer (DTE) baud rate as CONNECT xxxx Reports computer (DTE) rate and wireless rate between modems as CARRIER xxxx. Reports modem (DCE) baud rate as CONNECT xxxx Reset and load stored configuration The Z command resets the modem and loads the stored configuration. &C DCD (Data Carrier Detect) The &C command controls the modem’s DCD output signal to the host microprocessor. This command determines when the DCD is active. &C0 *&C1 &C2 &D DCD is always ON DCD on when modems are synchronized. DCD is always on when unit is configured as Master. DCD used for output data framing and Modbus mode. See page 25 for details. DTR (Data Terminal Ready) The &D command controls what action the modem performs when the DTR input line is toggled. The DTR input is controlled by the host microprocessor. *&D0 &D1 &D2 &D3 10 DTR line is ignored Not Supported DTR disconnects and switches to Command Mode DTR disconnects and resets modem. Modem will remain in this state until DTR again goes active. MHX-2400 Operating Manual: Chapter 3 Configuration Options &F &F1 Master Load Factory Default Configuration The &F command resets the modem and loads the default factory configuration. &F2 &F1 Slave &F2 &F3 &F1 Master &F3 Repeater &F4 &F4 Slave &K Master Point-to-Multipoint. Designed to communicate with modems configured as &F2 or &F3. Slave. Designed to communicate with another modem configured as &F1. Repeater. Designed to communicate with modems configured as &F1 and &F4. Slave working with factory default Repeater and factory default Master. Communicates directly with Repeater configured as &F3. Handshaking The &K command controls the handshaking between the modem and host microprocessor. &K0 &K2 *&K3 &S Disable handshaking RTS/CTS input data framing. See page 25 for details. Enable hardware handshaking (RTS/CTS) DSR (Data Set Ready) The &S command controls the DSR line for the modem, and determines when it is active &S0 *&S1 &V DSR is always ON DSR is ON in Data Mode, OFF in Command Mode View Configuration The &V command displays the current (DTE) baud rate, and all setable modem parameters including S register values. &E Framing Error Check This command enables or disables Framing Error Check. When enabled, the modem looks for the stop bit. If the stop bit is absent, the byte is thrown out. When enabled, the modem also does a parity check. Note that the data format (number of data bits, parity type, and number of stop bits) is defined by S register 110. *&E0 &E1 &W Disable Framing Error Check Enable Framing Error Check Write Configuration to Memory The &W command stores the active configuration into the modem’s nonvolatile memory. Sxxx? Read S register value This command causes the modem to display the current setting of S register xxx. Sxxx=yyy Set S register value (see section 3.3 S-Registers) This command sets the specified S register to a value specified by yyy. MHX-2400 Operating Manual: Chapter 3 Configuration Options 11 3.2 Command Result Codes The MHX-2400 module can either display the results of a command as either text strings or numerical data. The following chart shows resulting text string and corresponding numeric result. 10 12 13 14 15 17 18 33 62 64 12 OK NO CARRIER ERROR CONNECT 2400 CONNECT 3600 CONNECT 4800 CONNECT 7200 CONNECT 9600 CONNECT 14400 CONNECT 19200 CONNECT 28800 CONNECT 38400 CONNECT 57600 CONNECT 115200 CARRIER 45000 CARRIER 20000 MHX-2400 Operating Manual: Chapter 3 Configuration Options 3.3 S Registers S Register 0 - Auto Answer If this register is set to zero, the modem will power up in command mode. If this register is non-zero, the modem will power up in data mode. S Registers 2 through 5 cannot be stored to nonvolatile memory. S Register 2 - Escape Code This register contains the ASCII value of the escape character. The default value (decimal 43) is equivalent to the ASCII character ‘+’. Values greater than 127 disable the escape feature and prevent you from returning to the Command Mode. This register cannot be stored to nonvolatile memory. If the modem is reset, or powered down, the default value is restored. Default is ‘+’ (decimal 43). S Register 3 - CR Control Code This register contains the ASCII value of the carriage return character. This is the character that is used to end the command line and is also the character that appears after the modem sends a response. This register cannot be stored to non-volatile memory. If the modem is reset, or powered down, the default value is restored. Default is ‘CR’ (decimal 13). S Register 4 - Linefeed Control Code Register S4 sets the ASCII value of the linefeed character. The modem sends the linefeed character after sending a carriage return character when sending text responses. This register cannot be stored to non-volatile memory. If the modem is reset, or powered down, the default value is restored. Default is ‘LF’ (decimal 10). S Register 5 - Backspace Control Code Register S5 sets the ASCII value of the backspace character. This character is both the character created by entering BACKSPACE and the character echoed to move the cursor to the left. This register cannot be stored to non-volatile memory. If the modem is reset, or powered down, the default value is restored. Default is ‘BS’ (decimal 8). MHX-2400 Operating Manual: Chapter 3 Configuration Options 13 S Register 101 - Operating Mode The Operating Mode (register S101) partly defines the “personality” of the MHX-2400 module. Allowable settings for this register are 1 through 4 as follows:. • • • • Only one Master can exist for each network. S101=1 S101=2 S101=3 S101=4 Master Point to Multipoint Master Point to Point Slave Repeater The default for this register depends on which factory default is selected as shown below: • • • • Default for Factory Setting &F1 is 1 (Master Point-to-Multipoint) Default for Factory Setting &F2 is 3 (Slave) Default for Factory Setting &F3 is 4 (Repeater) Default for Factory Setting &F4 is 3 (Slave) 1)Master - Point to Multipoint. In any given network, there is always only one Master. All other units should be configured as either Slaves or Repeaters. When defined as a Point-to-Multipoint Master, the modem broadcasts data to all Slaves and Repeaters in the network, and is also the ultimate destination for data transmitted by all Slaves and Repeaters. In addition, the Master defines the following network parameters to be utilized by all other modems in the network (See the appropriate sections for a complete description of these parameters): n Maximum Packet Size (S112) n Minimum Packet Size (S111) n Wireless Link Rate (S103) n Hop Interval (S109) 2)Master - Point to Point. This mode of operation is identical to Master Point-to-Multipoint, with the exception that the Master only broadcasts to one particular Slave or Repeater. The modem with which communication occurs is defined by the Unit Address (S105). For example, if a Slave has been assigned Unit Address 100, and the Master wishes to communicate with that Slave, the Master must also be assigned a Unit Address of 100. If there are Repeaters in the network, they will pass the packet through to the Slave, and vice versa. Because Repeaters also have Slave functionality (i.e., a Repeater can be connected to a terminal), the Master can choose to communicate solely with a Repeater. This would be accomplished by assigning the same Unit Address to both the Master and the Repeater. 14 MHX-2400 Operating Manual: Chapter 3 Configuration Options 3)Slave. Up to 65534 Slaves may exist in a network, all of which communicate with the common Master (either directly or via Repeater(s)). Slaves cannot directly communicate with other Slaves, nor can they acknowledge packets of data sent by the Master. Clearly this would cause conflicts when there are multiple Slaves. The Master does, however, send acknowledgements to all messages it receives from Slaves. The Master initiates communications by sending a broadcast message to all Slaves. All Slaves are free to respond in a “Slotted ALOHA” fashion, meaning that each Slave can choose one of several windows in which to transmit. If there happens to be two Slaves attempting to talk at the same time, the Master may not receive the data, and the Slaves therefore would not get an acknowledgement. At this point, the Slaves would attempt to get the information through at random time intervals, thus attempting to avoid any more conflicts. Special parameters which control the Slave’s response characteristics can be modified with S Registers S115 and S213. Network 50 Hop Pattern 2 PHP=1 Master PHP=1 SHP=2 PHP=2 Slave Repeater Hop Pattern 1 Figure 3 - Repeater Operation Hop Pattern 3 Repeater Slave PHP=2 PHP=3 SHP=3 Master PHP=1 HopPattern 1 Repeater PHP=1 SHP=2 Slave PHP=2 4) Repeater. A more precise title would be Repeater/Slave, because a Repeater also has much of the same functionality as a Slave. A terminal can be connected at the Repeater location and communicate with the Master terminal. There is no restriction to the number of Repeaters in a network, allowing for communication over virtually limitless distances. The presence of one Repeater in a network automatically degrades system throughput by half. Additional Repeaters, regardless of the quantity, do not diminish system throughput any further. To understand Repeater operation, consider the module as belonging to two hopping patterns at the same time: The Primary Hopping Pattern and the Secondary Hopping Pattern. In Figure 3, the Master belongs to Hopping Pattern 1, and communicates with the Repeater on this hopping pattern. The Slave belongs to Hopping Pattern 2, and communicates with the Repeater on this hopping pattern. The whole system belongs to Network 50 (i.e., all units must be assigned the same Network Address (S104), which in this case was selected to be 50. Note that Slaves and Master only communicate on their respective Primary Hopping Pattern. Repeaters communicate on the Primary Hopping Pattern when communicating with the Master (or with another Repeater between itself and the Master). Repeaters communicate on their Secondary Hopping Pattern when communicating with Slaves (or with another Repeater between itself and the Slaves). Figure 4 shows another example. If the Repeater is not also being used as a Slave (there is no DTE connected to the serial port), it is recommended that the Repeater’s baud rate be set to 115K, and that handshaking be disabled (&K0). This will help ensure a smooth flow of data through the network. Hop Pattern 2 Figure 4 - A Network Utilizing Three Hopping Patterns If there is no DTE connected to the Repeater, turn off handshaking (&K0) and set the baud rate to 115K. MHX-2400 Operating Manual: Chapter 3 Configuration Options 15 S Register 102 - Serial Baud Rate The Serial Baud Rate is the current speed that the modem is using to communicate with the DTE. When the AT command prefix is issued, the modem performs an ‘autobaud’ operation and determines what the current DTE baud rate is set to. The S register value returns the current setting of the DTE baud rate. The possible values are: *1 10 11 115200 57600 38400 28800 19200 14400 9600 7200 4800 3600 2400 It is generally advisable to choose the highest rate that your terminal equipment will handle to maximize performance, unless a limitation on the available bandwidth is desired. If the DTE is a personal computer, the port can usually be used reliably at 115200. It is not possible to write values to this register, since the instant another AT command is issued, the register will revert to the current baud rate. Therefore, it is advisable to operate in Command Mode at the desired baud rate for Data Mode. The Master determines the Wireless Link Rate. This setting on all other modems is ignored.. S Register 103 - Wireless Link Rate The Wireless Link Rate is the speed and optimization method for which modems will communicate over the RF link. It is only necessary to set this parameter on the Master unit. Units configured as Repeaters and Slaves will ignore this setting, and adjust automatically to the rate of the Master. The allowable settings are: *4 Fast without Forward Error Correction Fast with Forward Error Correction Depending on the application requirements, each mode will provide different throughput and performance. Appendix E. Performance Tables give some indication of the performance to be expected in each mode. In general, Forward Error Correction (FEC) reduces throughput, but in some environments will actually increase throughput. FEC can reduce the number of bad data packets, and hence reduce the need to retransmit. 16 MHX-2400 Operating Manual: Chapter 3 Configuration Options S Register 104 - Network Address Select a Network Address and assign it to all units which will be included in the network. The Network Address defines the membership to which individual units can be a part of. By establishing a network under a common Network Address, the network can be isolated from any other concurrently operating network. As well, the Network Address provides a measure of privacy and security. Only those units which are members of the network will participate in the communications interchange. Valid values for the Network Address range from 0 to 65535, inclusive. To enhance privacy and reliability of communications where multiple networks may operate concurrently in close proximity, it is suggested that an atypical value be chosen – perhaps something meaningful yet not easily selected by chance or coincidence. Default is 1. Use the same Unit Address on both units for point-topoint mode. In multipoint mode, set each Slave and Repeater to a different Unit Address. Valid Unit Addresses are 1 to 65535. S Register 105 - Unit Address In point-to-point operation, the Unit Address on both the Master and Slave (or Repeater) units must be the same. In a multipoint system, the Unit Address uniquely identifies each Slave and Repeater from one another. Each unit in a multipoint system must have a unique Unit Address ranging from 1 to 65535. Do not use 0 as a Unit Address, and do not use a Unit Address more than once within the same Network. This is required because the Master must be able to acknowledge each unit individually, based on the Unit Address. S Register 106 - Primary Hopping Pattern S Register 206 - Secondary Hopping Pattern Since the MHX-2400 is a frequency-hopping modem, the carrier frequency changes periodically according to one of 49 pseudo-random patterns, defined by the Primary and Secondary Hopping Patterns. Valid entries for each are 0 through 50. The concept of Primary and Secondary Hopping Patterns was introduced in the discussion of S Register 101 (Operating Mode). Using the designations M[a,] Rx[a,b] and Sx[a] where: - M indicates Master; - R indicates Repeater; - S indicates Slave; - x is the Unit Address; - a is the primary hopping pattern; and, - b is the secondary hopping pattern; MHX-2400 Operating Manual: Chapter 3 Configuration Options 17 the following diagrams illustrate the methodology for deploying simple to complicated networks: Master Slave Master Repeater Master Repeater1 M[1] ←→ S1[1] M[1] ←→ R1[1,2] ←→ S2[2] M[1] ←→ R1[1,2] ←→ R2[2,3] ←→ S3[3] M[1] ←→ R1[1,2] ←→ R2[2,3] ←→ R3[3,4] ←→ S4[4] Slave Repeater2 Slave It is reasonable to consider a Repeater as being both a Slave and a Master, alternating between Primary and Secondary Hopping Patterns as the unit changes channel. Consider R1 in the illustration below. When communicating with the Master, R1 is acting like a Slave on Primary Hopping Pattern 1. When communicating with R2 and S4, R1 is acting like a Master on Secondary Hopping Pattern 2. If multiple Repeaters are used, they should have different Secondary Hopping Patterns: ←→ R1[1,2] M[1] Slaves and Masters do not use Secondary Hopping Patterns ←→ R2[2,5] ←→ S4[2] ←→ R5[1,3] ←→ R6[3,6] ←→ R8[1,4] ←→ S9[4] ←→ S3[5] ←→ S7[6] Note that all units have a unique Unit Address. Remember to assign a unique Unit Address (1 to 65535) to each unit in the system Networks of any complexity can be created by linking multiple Repeaters and Slaves: ←→ R1[1,2] ←→ M[1] ←→ S2[2] ←→ S3[2] ←→ R5[3,6] R4[1,3] ←→ ←→ S11[1] ←→ S12[1] R8[3,7] ←→ S6[6] ←→ S7[6] ←→ R9[7,8] ←→ S10[8] With a limitation of 51 hopping patterns, one might suspect that there is a limitation to the number of repeaters in a system. However, if the units are far enough away from one another, hopping patterns may be reused in different sections of the network, without causing interference. 18 MHX-2400 Operating Manual: Chapter 3 Configuration Options S Register 107 - Encryption Key All units within a network must use the same encryption key. The Encryption Key provides a measure of security and privacy of communications by rendering the transmitted data useless without the correct key on the receiver. Valid Encryption Keys range from 0 to 65535. Keep in mind that all units within the network must use the same key for communications to succeed. S Register 108 - Output Power Level The Output Power Level determines at what power the MHX-2400 transmits. The super-sensitive MHX-2400 can operate with very low power levels, so it is recommended that the lowest power necessary is used; using excessive power contributes to unnecessary “RF pollution”. The allowable settings are: *2 10 mW 50 mW 100 mW 250 mW 1W 500 mW 750 mW Ideally, you should test the communications performance between units starting from a low power level and working upward until the RSSI is sufficiently high and a reliable link is established. Although the conditions will vary widely between applications, typical uses for some of the settings are described below: Power Use For in-building use, typically provides a link up to 300 feet on the same floor or up/down a level. Outdoors, distances of 10 km can be achieved if high-gain (directional) antennas are placed high above ground level and are in direct line-of-sight. 50 mW 200-500 ft indoors, 8-15 km* outdoors. 100 mW 400-800 ft indoors, 15-25 km* outdoors. 1000 mW Typically provides communications up to a distance of 1000 feet or (1 W) more in-building on the same floor or up/down a few levels, depending on building construction (wood, concrete, steel, etc.). In ideal line-of-sight conditions, up to 30 km* or more can be achieved. Note that only an antenna with a gain of no more than 6 dBi may be used. Any higher is a violation of FCC rules. See IMPORTANT warning below. * These outdoor distances assume antennas are mounted at least 100 ft above ground level 10 mW MHX-2400 Operating Manual: Chapter 3 Configuration Options 19 IMPORTANT: FCC Regulations allow up to 36 dBi effective radiated power (ERP). Therefore, the sum of the transmitted power (in dBm), the cabling loss and the antenna gain cannot exceed 36 dBi. 1 mW = 0 dBm 10 mW = 10 dBm 100 mW = 20 dBm 1000 mW = 30 dBm For example, when transmitting 1 Watt (30 dBm), with cabling losses of 2 dB, the antenna gain cannot exceed 36 - 30 + 2 = 8 dBi. If an antenna with a gain higher than 8 dBi were to be used, the power setting must be adjusted appropriately. Violation of FCC regulations can result in severe fines. The hopping interval is controlled by the master. The slave and repeater units will use the hopping interval setting from the master. S Register 109 - Hopping Interval This option determines the frequency at which the modems change channel. Note that the Master controls this parameter for the entire network. This setting is ignored in units configured as Slaves or Repeaters. The allowable settings are: *8 8 msec 12 msec 16 msec 20 msec 30 msec 45 msec 80 msec 120 msec See Appendix E for optimal Hopping Interval settings in relation to packet size and link rate. S Register 110 - Data Format This register determines the format of the data on the serial port. Allowable settings are: *1 10 11 20 8 bits, No Parity, 1 Stop 8 bits, No Parity, 2 Stop 8 bits, Even Parity, 1 Stop 8 bits, Odd Parity, 1 Stop 7 bits, No Parity, 1 Stop 7 bits, No Parity, 2 Stop 7 bits, Even Parity, 1 Stop 7 bits, Odd Parity, 1 Stop 7 bits, Even Parity, 2 Stop 7 bits, Odd Parity, 2 Stop 9 bits, No Parity, 1 Stop MHX-2400 Operating Manual: Chapter 3 Configuration Options S Register 111 - Packet Minimum Size S Register 112 - Packet Maximum Size S Register 116 - Packet Character Timeout These settings determine the conditions under which the modem will transmit accumulated data over the air. S Register 111 - Minimum Size Valid entries for this register are 1 to 255 bytes, which defines the minimum number of bytes to receive from the DTE before encapsulating them in a packet and transmitting over the air. The Minimum and Maximum Packet Size is controlled by the Master. The Slave and Repeater units will use the Minimum and Maximum Packet Size setting from the Master. Note that the minimum packet size for all modems in the network is determined by the Master only. This setting is ignored in all Slave and Repeater modems. The default is 1 byte. S Register 112 - Maximum Size This setting has a range of 2 to 255, and defines the maximum number of bytes from the DTE which should be encapsulated in a packet. This value should be greater than the minimum packet size, but not smaller than is necessary for reliable communications. If the wireless link is consistently good and solid, a maximum size of 255 will yield the best throughput (depending on the higher level protocols of the connected equipment). However, if the link is poor (e.g., experiencing excessive interference) and data is frequently retransmitted, the maximum packet size should be reduced. This decreases the probability of errors within packets, and reduces the amount of traffic in the event that retransmissions are required. Note that the maximum packet size for all modems in the network is determined by the Master only. This setting is ignored in all Slave and Repeater modems. The default is 255 bytes. S Register 116 - Packet Character Timeout This register has valid entries of 0 to 254 milliseconds. The Packet Character Timeout timer looks for gaps in the data being received from the DTE. The timer is only activated after the Minimum Packet Size has been accumulated in the modem. After which, if the timer detects a gap in the data exceeding the Packet Character Timeout value, the modem will transmit the data. The MHX-2400 will accumulate data in its buffers from the DTE until one of the following requirements is met (whichever occurs first): • The Maximum Packet Size (in bytes) has been accumulated; • The Minimum Packet Size has been accumulated AND the Packet Character Timeout interval has elapsed. The default for the Packet Character Timeout is 9 ms. If set to 0 ms, the unit will buffer exactly the minimum packet size before transmitting. MHX-2400 Operating Manual: Chapter 3 Configuration Options 21 S Register 113 - Packet Retransmissions This register applies to both Master and Repeater operation. It does not apply to Slave operation. The Master will retransmit each data packet exactly the number of times defined by the Packet Retransmissions parameter. The Master retransmits once at the beginning of each hopping interval until the limit is reached. This parameter is not necessary in Slave units since all Slaves receive acknowledgement from the Master. As discussed previously, the Repeater effectively behaves as both a Master and a Slave. When the Repeater is tuned to its Secondary Hopping Pattern (acting as a Master), the Packet Retransmissions Parameter comes into play. The Repeater will re-send packets of data on to Slaves or other Repeaters exactly the number of times defined by the Packet Retransmissions parameter. Recipients of the packet will discard any duplicates The valid settings for this parameter are 0 to 255 retransmissions. The default is 2. S Register 213 - Packet Retry Limit Packet Retry Limit is analogous to Packet Retransmissions, but specifically applies to Slaves and Repeaters. This parameter is not used by the Master. Because the Slave has the advantage of receiving acknowledgements from the Master, it is not necessary to blindly retransmit each packet. If the Slave does not get an acknowledgement on the next hop, it will retransmit its packet. This will continue until the Packet Retry Limit is reached or an acknowledgement is received. If the limit is reached, the modem will give up and discard the data. Valid settings are 0 to 255 retries. The default value is 2. The Repeater makes use of this parameter when it is tuned to its Primary Hopping Pattern and is acting like a Slave. 22 MHX-2400 Operating Manual: Chapter 3 Configuration Options S Register 115 - Packet Repeat Interval A parameter that is specific to Slaves and Repeaters is the Packet Repeat Interval. The allowable settings are 1 through 255. The default is 1. This parameter defines a range of random numbers that the Slave will use as the next slot in which it will attempt to send the packet. For example, if this register is set to 7, the Slave will choose a number between one and seven as the next slot in which to transmit. Suppose the random number generator picks 5, then the Slave will transmit in the fifth time slot. A Slave will transmit a maximum of once per hopping interval, however, depending on the duration of the hopping interval and the maximum packet size, more than one slot per hop is potentially available. The Slave will transmit more frequently when a Repeat Interval with a smaller range is selected. Choose 1 to have the Slave transmit in the first available slot. Choose higher intervals for less frequent transmission, or to avoid collisions between many Slaves in the system. S Register 117 - Modbus Mode Modbus Mode allows for the MHX-2400 to be fully Modbus compatible. Please contact Microhard Systems for assistance when configuring the unit for Modbus operation. Optimal Modbus settings rely on several other S Register parameters. The allowable settings for this register are: *0 Disabled Enabled MHX-2400 Operating Manual: Chapter 3 Configuration Options 23 S Register 120 - RTS/DCD Framing S Register 121 - DCD Timeout The MHX-2400 supports two special types of data framing: • • Input (or RTS/CTS) Data Framing; and, Output (or DCD) Data Framing Input Data Framing is enabled by configuring the Handshaking Parameter as &K2. This type of framing makes use of the S120 parameter as illustrated in Figure 5. Parameter S120 can be set to any value between 0 and 254 ms. RTS CTS TXD Data going into MHX-910 0 to 1 ms S120 (ms) Figure 5 - Input Data Framing To enable output (DCD) data framing, set the Data Carrier Detect parameter as &C2. This type of framing uses both S120 and S121 registers as shown in Figure 6. Valid ranges for each parameter are 0 to 254 ms. DCD RXD Data leaving MHX-910 S120 (ms) S121 (ms) Figure 6 - Output Data Framing S Register 123 - RSSI Reading This register displays the average signal strength in dBm over the previous four hop intervals. Valid RSSI readings apply only to units configured as Slave or Repeater. 24 MHX-2400 Operating Manual: Chapter 3 Configuration Options MHX-2400 Operating Manual: Chapter 3 Configuration Options 25 A. Modem Command Summary The following provides a command summary for the MHX-2400 module. Factory settings are denoted with a ‘*’. AT Commands Answer Command Echo E0 No Echo * E1 Command Echo Identification I0 Product Code I2 ROM Checksum test I3 Firmware Version I4 Firmware Date I5 Copyright I6 Firmware Time On-line Mode Quiet Mode * Q0 Enables Result Codes Q1 Disables Result Codes Result Codes Display V0 Display as Numbers * V1 Display as Words Connection Result * W0 Reports DTE as CONNECT xxxx W1 Reports computer (DTE) rate and wireless rate between modems as CARRIER xxxx. W2 Reports DCE as CONNECT xxxx Reset and load stored configuration &C DCD (Data Carrier Detect) &C0 DCD is always on * &C1 DCD is on when modems are synchronized &C2 DCD used for output data framing &D DTR (Data Terminal Ready) &D0 DTR ignored * &D2 DTR disconnects and switches to command &D3 DTR disconnects and resets modem &F Load Factory Default &F1 Master &F2 Slave &F3 Repeater &F4 Slave through Repeater &K Handshaking &K0 Disable Handshaking &K2 RTS/CTS Input Framing * &K3 Enable Handshaking &S DSR (Data Set Ready) &S0 DSR is always on * &S1 DSR on in data, off in command mode &V View Configuration &W Write configuration to memory Sxx? Read S register value Sxx=yy Set S register value Result Codes OK 12 CONNECT 9600 NO CARRIER 13 CONNECT 14400 ERROR 14 CONNECT 19200 CONNECT 2400 15 CONNECT 28800 CONNECT 3600 17 CONNECT 38400 CONNECT 4800 18 CONNECT 57600 10 CONNECT 7200 33 CONNECT 115200 64 CARRIER 20000 62 CARRIER 45000 26 S Registers S0 Auto Answer [0...255] 0 = power up in Command Mode, non-zero = power up in Data Mode S2 Escape code [0...255] default ‘+’ S3 CR character [0...255] default S4 Line Feed [0...255] default S5 Backspace [0...255] default S101 Operating Mode 1 - Master Point to Multipoint 2 - Master Point to Point 3 - Slave 4 - Repeater S102 Serial Baud Rate *1 = 115200, 2 = 57600, 3 = 38400 4 = 28800, 5 = 19200, 6 = 14400 7 = 9600, 8 = 7200, 9 = 4800, 10 = 3600, 11 = 2400 S103 Wireless Link Rate 2 = Fast w/o FEC *4 = Fast with FEC S104 Network Address [0...65535] S105 Unit Address [1...65535] S106 Primary Hopping Pattern [0...50] S206 Secondary Hopping Pattern [0...50] S107 Encryption Key [0...65535] S108 Output Power Level 0 = 10 mW, 1 = 50 mW, *2 = 100 mW, 3 = 250 mW 4 = 500 mW, 5 = 750 mW, 6 = 1W S109 Hopping Interval 1 = 8 msec, 2 = 12 msec, 3 = 16 msec, 4 = 20 msec, 5 = 30 msec, 6 = 45 msec, 7 = 80 msec, *8 = 120 msec S110 Data Format * 1 = 8N1, 2 = 8N2, 3 = 8E1, 4 = 8O1 5 = 7N1, 6 = 7N2, 7 = 7E1, 8 = 7O1 9 = 7E2, 10 = 7O2, 11 = 9N1 S111 Packet Minimum Size [1...Maximum Size] S112 Packet Maximum Size [2...255] S113 Packet Retransmissions [0...255] S213 Packet Retry Limit [0...255] S115 Packet Repeat Interval [1..255] Default = 1 S116 Packet Character Timeout [0...254 ms] S117 Modbus Mode *0 = Disabled, 1 = Enabled S120 RTS/DCD Framing Interval [0...254 ms] S121 DCD Timeout [0...254 ms] MHX-2400 Operating Manual: Appendix A. Modem Command Summary MHX-2400 Operating Manual: RS-232 Interface and Cables 27 B. Serial Interface The MHX-2400 module uses 8 pins on the header connector for asynchronous serial I/O. The interface conforms to standard RS-232 signals without level shifting, so direct connection to a host microprocessor is possible. The signals in the asynchronous serial interface are described below: DCD Data Carrier Detect - Output from Modem - When asserted (TTL low), DCD informs the DTE that a communications link has been established with another MHX-2400. Modem (DCE) ← ← ← Host Microprocessor Signal (DTE) DCD RX TX DTR SG DSR RTS CTS → IN → IN OUT OUT → IN → IN OUT → IN Arrows denote the direction that signals are asserted (e.g., DCD originates at the DCE and tells the DTE that a carrier is present). RX Receive Data - Output from Modem - Signals transferred from the MHX2400 are received by the DTE via RX. TX Transmit Data - Input to Modem - Signals are transmitted from the DTE via TX to the MHX-2400. DTR Data Terminal Ready - Input to Modem - Asserted (TTL low) by the DTE to inform the modem that it is alive and ready for communications. SG Signal Ground - Provides a ground reference for all signals transmitted by both DTE and DCE. DSR Data Set Ready - Output from Modem - Asserted (TTL low) by the DCE to inform the DTE that it is alive and ready for communications. DSR is the modem’s equivalent of the DTR signal. RTS Request to Send - Input to Modem - A “handshaking” signal which is asserted by the DTE (TTL low) when it is ready. When hardware handshaking is used, the RTS signal indicates to the DCE that the host can receive data. CTS Clear to Send - Output from Modem - A “handshaking” signal which is asserted by the DCE (TTL low) when it has enabled communications and transmission from the DTE can commence. When hardware handshaking is used, the CTS signal indicates to the host that the DCE can receive data. Notes: It is typical to refer to RX and TX from the perspective of the DTE. This should be kept in mind when looking at signals relative to the modem (DCE); the modem transmits data on the RX line, and receives on TX. “DCE” and “modem” are often synonymous since a modem is typically a DCE device. “DTE” is, in most applications, a device such as a host microprocessor. MHX-2400 Operating Manual: Appendix B Serial Interface 29 30 MHX-2400 Operating Manual: Appendix B Serial Interface C. Sample Schematic Diagram The following is a sample microprocessor implementation with a MICROCHIP PIC 16C74 and the MHX-2400. The MHX2400 performs no level shifting on the serial port, so direct connection to the host microprocessor is possible. DO NOT CONNECT THE MHX-2400 TO RS 232 DRIVER OUTPUTS. DAMAGE TO THE UNIT MAY RESULT. On this implementation, the onboard SCI of the PIC 16C74 is directly connected pins 2 and 3 of the MHX-2400. The bidirectional Port D is used for asserting or monitoring control signals from the MHX-2400. The RESET and CONFIG signals are momentary active low signals asserted by the host microprocessor. RESET initializes the MHX-2400 and places the system in a known state. This signal should be set high after the host microprocessor has been reset. The CONFIG line is reserved for factory use. This signal should be set high. PIC16C74 MHX-900 RC7 RC6 RXD TXD RD0 RD1 RD2 RD3 RD4 DCD DTR DSR RTS CTS RD5 RD6 CONFIG RESET 32 31 Power Connections not shown MHX-2400 Operating Manual: Appendix C Sample Schematic Diagram 31 32 MHX-2400 Operating Manual: Appendix C Sample Schematic Diagram D. Factory Default Settings AT&F1 - Master Default Settings AT&F3 - Repeater Default Settings E1, Q0, V1, W0, S0=0, S2=43, S3=13, S4=10, S5=8 E1, Q0, V1, W0, S0=1, S2=43, S3=13, S4=10, S5=8 DCD DTR Framing Handshaking DSR Operating Mode Serial Baud Rate Wireless Link Rate Network Address Unit Address Primary Hop Pattern Encryption Key Output Power Hop Interval Data Format Packet Minimum Size Packet Maximum Size Packet Retransmissions &C1 (On) &D0 (DTR is ignored) &E0 (Disabled) &K3 (Enabled) &S1 (On in Data, Off in Command) S101=1 (Master P-MP) S102=1 (115kbaud) S103=4 (Fast, FEC) S104=1 S105=1 S106=0 S107=1 S108=2 (100mW) S109=8 S110=1 (8N1) S111=1 S112=255 S113=2 DCD DTR Framing Handshaking DSR Operating Mode Serial Baud Rate Wireless Link Rate Network Address Unit Address Primary Hop Pattern Encryption Key Output Power Hop Interval Data Format Packet Minimum Size Packet Maximum Size Packet Retransmissions &C1 (On when modems are synced) &D0 (DTR is ignored) &E0 (Disabled) &K3 (Enabled) &S1 (On in Data, Off in Command) S101=4 (Repeater) S102=1 (115kbaud) S103=4 (Fast, FEC) (Set by Master) S104=1 S105=3 S106=0 S107=1 S108=2 (100mW) S109=8 (Set by Master) S110=1 (8N1) S111=1 (Set by Master) S112=255 (Set by Master) S113=2 Packet Repeat Interval Character Timeout (ms) Modbus Mode RTS/DCD Framing (ms) DCD Timeout (ms) Secondary Hop Pattern Packet Retry Limit S115=1 (Don’t Care) S116=8 S117=0 S120=0 S121=0 S206=2 (Don’t Care) S213=2 (Don’t Care) Packet Repeat Interval Character Timeout (ms) Modbus Mode RTS/DCD Framing (ms) DCD Timeout (ms) Secondary Hop Pattern Packet Retry Limit S115=1 S116=8 S117=0 S120=0 S121=0 S206=2 S213=2 AT&F2 - Slave Default Settings AT&F4 -Slave Through Repeater Default Settings E1, Q0, V1, W0, S0=1, S2=43, S3=13, S4=10, S5=8 E1, Q0, V1, W0, S0=1, S2=43, S3=13, S4=10, S5=8 DCD DTR Framing Handshaking DSR Operating Mode Serial Baud Rate Wireless Link Rate Network Address Unit Address Primary Hop Pattern Encryption Key Output Power Hop Interval Data Format Packet Minimum Size Packet Maximum Size Packet Retransmissions &C1 (On when modems are synced) &D0 (DTR is ignored) &E0 (Disabled) &K3 (Enabled) &S1 (On in Data, Off in Command) S101=3 (Slave) S102=1 (115kbaud) S103=4 (Fast, FEC) (Set by Master) S104=1 S105=2 S106=0 S107=1 S108=2 (100mW) S109=8 (Set by Master) S110=1 (8N1) S111=1 (Set by Master) S112=255 (Set by Master) S113=2 (Don’t Care) DCD DTR Framing Handshaking DSR Operating Mode Serial Baud Rate Wireless Link Rate Network Address Unit Address Primary Hop Pattern Encryption Key Output Power Hop Interval Data Format Packet Minimum Size Packet Maximum Size Packet Retransmissions &C1 (On when modems are synced) &D0 (DTR is ignored) &E0 (Disabled) &K3 (Enabled) &S1 (On in Data, Off in Command) S101=3 (Slave) S102=1 (115kbaud) S103=4 (Fast, FEC) (Set by Master) S104=1 S105=4 S106=2 S107=1 S108=2 (100mW) S109=8 (Set by Master) S110=1 (8N1) S111=1 (Set by Master) S112=255 (Set by Master) S113=2 (Don’t Care) Packet Repeat Interval Character Timeout (ms) Modbus Mode RTS/DCD Framing (ms) DCD Timeout (ms) Secondary Hop Pattern Packet Retry Limit S115=1 S116=9 S117=0 S120=0 S121=0 S206=2 (Don’t Care) S213=2 Packet Repeat Interval Character Timeout (ms) Modbus Mode RTS/DCD Framing (ms) DCD Timeout (ms) Secondary Hop Pattern Packet Retry Limit S115=1 S116=8 S117=0 S120=0 S121=0 S206=2 (Don’t Care) S213=2 MHX-2400 Operating Manual: Appendix D. Factory Default Settings 33 34 MHX-2400 Operating Manual: Appendix D Factory Default Settings E. Performance Tables The scope of this appendix is to find the best possible performance and maximum packet size at different modes of operation. The setup assumes a baud rate of 115k, no retries and no retransmissions.. Slave to Master Communication. (No Repeater) Link Rate = Fast NO FEC Slave to Master Communication. (No Repeater) Link Rate = Fast WITH FEC Repeater to Master Direct Communication. Link Rate = Fast NO FEC Repeater to Master Direct Communication. Link Rate = Fast WITH FEC Slave to Master Through One or More Repeaters. Link Rate = Fast NO FEC Slave to Master Through One or More Repeaters. Link Rate = Fast WITH FEC Hop Interval 1 (8 ms) 2 (12 ms) 3 (16 ms) 4 (20 ms) 5 (30 ms) 6 (45 ms) 7 (80 ms) 8 (120 ms) 1 (8 ms) 2 (12 ms) 3 (16 ms) 4 (20 ms) 5 (30 ms) 6 (45 ms) 7 (80 ms) 8 (120 ms) 1 (8 ms) 2 (12 ms) 3 (16 ms) 4 (20 ms) 5 (30 ms) 6 (45 ms) 7 (80 ms) 8 (120 ms) 1 (8 ms) 2 (12 ms) 3 (16 ms) 4 (20 ms) 5 (30 ms) 6 (45 ms) 7 (80 ms) 8 (120 ms) 1 (8 ms) 2 (12 ms) 3 (16 ms) 4 (20 ms) 5 (30 ms) 6 (45 ms) 7 (80 ms) 8 (120 ms) 1 (8 ms) 2 (12 ms) 3 (16 ms) 4 (20 ms) 5 (30 ms) 6 (45 ms) 7 (80 ms) 8 (120 ms) Optimal Packet Size (bytes) 14 66 110 154 255 255 255 255 34 54 76 130 210 255 255 N/A 22 44 101 178 255 255 N/A N/A 16 43 80 174 255 N/A 22 43 93 174 255 255 N/A N/A N/A 14 40 80 Throughput (kbps)* 20 52 66 74 83 56 31 21 22 28 32 38 43 30 20 N/A 13 21 32 39 31 21 N/A N/A 12 16 20 20 N/A 13 21 31 38 31 21 N/A N/A N/A 12 16 174 255 19 20 MHX-2400 Operating Manual: Appendix E. Performance Tables 35 36 MHX-2400 Operating Manual: Appendix E. Performance Tables F. Hopping Patterns This Appendix provides a guide for selecting appropriate hopping patterns (S106,S206). There are 49 hopping patterns: Patterns have been designed to notch out certain segments of the ISM band. Pattern Number Spectrum Used 0-7 2.4012 - 2.4824 GHz 8 - 10 2.4012 - 2.4312 GHz 11 - 13 2.4052 - 2.4352 GHz 14 - 16 2.4092 - 2.4392 GHz 17 - 19 2.4132 - 2.4432 GHz 20 - 22 2.4172 - 2.4472 GHz 23 - 25 2.4212 - 2.4512 GHz 26 - 28 2.4252 - 2.4552 GHz 29 - 31 2.4292 - 2.4592 GHz 32 - 34 2.4332 - 2.4632 GHz 35 - 37 2.4372 - 2.4672 GHz 38 - 40 2.4412 - 2.4712 GHz 41 - 43 2.4452 - 2.4752 GHz 44 - 46 2.4492 - 2.4792 GHz 47 - 48 2.4520 - 2.4820 GHz Patterns 44 to 48 may be manually edited by entering AT&H at the Command Line. Each pattern must use a channel only once, and must consist of exactly 76 channels. There are 202 channels available ranging from Channel 1 at 2.4016 GHz up to Channel 202 at 2.4820 GHz MHX-2400 Operating Manual: Appendix F. Hopping Patterns 37 38 MHX-2400 Operating Manual: Appendix F. Hopping Patterns G. Technical Specifications Electrical/Physical Data Interface Asynchronous Serial Port, TTL Levels Signals Sig. Gnd, TX, RX, DCD, DSR, DTR, RTS, CTS Bandwidth / Data Rate 2,400 - 115,200 bps, uncompressed half-duplex, Approx. 100 kbps sustained in intelligent asymmetrical full-duplex transmission mode Communications Range1 30 kilometres (19 miles) Power Requirements 5 VDC, 1.0 Amp Power Consumption 700 mA max, 450 mA typical at 1W transmit; 200 mA receive Operating Frequency 2.4000 GHz to 2.4835 GHz System Gain 135 dB Sensitivity -105 dBm Output Power 10, 50, 100, 250, 500, 750, 1000mW (user-selectable) Spreading Code Frequency Hopping Hopping Patterns 20 pseudo-random, user-selectable Error Detection CRC-16 with auto re-transmit Error Correction Dimensions (LxWxH) User-selectable Forward Error Correction (FEC) Encl: 3.5” x 2.1” x 1.” (90 mm x 53 mm x 25 mm) Weight 75 grams Operating Environment Temperature: -40 to +70°C Humidity: 5 to 95%, non-condensing Storage Temperature -40 to 90°C 1. Clear line-of-sight, elevated high-gain antennas. MHX-2400 Operating Manual: Appendix G. Technical Specifications 39 40 MHX-2400 Operating Manual: Appendix G. Technical Specifications H. Glossary Terminology Used in the MHX-2400 Operating Manual Asynchronous communications A method of telecommunications in which units of single bytes of data are sent separately and at an arbitrary time (not periodically or referenced to a clock). Bytes are “padded” with start and stop bits to distinguish each as a unit for the receiving end, which need not be synchronized with the sending terminal. Attenuation The loss of signal power through equipment, lines/cables, or other transmission devices. Measured in decibels (dB). Bandwidth The information-carrying capacity of a data transmission medium or device, usually expressed in bits/second (bps). Baud Unit of signaling speed equivalent to the number of discrete conditions or events per second. If each signal event represents only one bit condition, then baud rate equals bits per second (bps) – this is generally true of the serial data port, so baud and bps have been used interchangeably in this manual when referring to the serial port; this is not always the case during the DCE-to-DCE communications, where a number of modulation techniques are used to increase the bps rate over the baud rate. Bit The smallest unit of information in a binary system, represented by either a 1 or 0. Abbreviated “b”. Bits per second (b/s or bps) A measure of data transmission rate in serial communications. Also see baud. Byte A group of bits, generally 8 bits in length. A byte typically represents a character of data. Abbreviated “B”. Characters per second (cps) A measure of data transmission rate for common exchanges of data. A character is usually represented by 10 bits: an 8bit byte plus two additional bits for marking the start and stop. Thus, in most cases (but not always), cps is related to bits per second (bps) by a 1:10 ratio. CRC (Cyclic Redundancy Check) An error-detection scheme for transmitted data. Performed by using a polynomial algorithm on data, and appending a checksum to the end of the packet. At the MHX-2400 Operating Manual: Appendix H. Glossary receiving end, a similar algorithm is performed and checked against the transmitted checksum. Crossover cable (Also known as rollover, null- modem, or modem-eliminator cable) A cable which allows direct DTE-to-DTE connection without intermediate DCEs typically used to bridge the two communicating devices. Can also be used to make cabled DCE-to-DCE connections. The name is derived from “crossing” or “rolling” several lines, including the TX and RX lines so that transmitted data from one DTE is received on the RX pin of the other DTE and vice-versa. Data Communications Equipment (DCE, also referred to as Data Circuit-Terminating Equipment, Data Set) A device which facilitates a communications connection between Data Terminal Equipment (DTEs). Often, two or more compatible DCE devices are used to “bridge” DTEs which need to exchange data. A DCE performs signal encoding, decoding, and conversion of data sent/received by the DTE, and transmits/receives data with another DCE. Common example is a modem. Data Terminal Equipment (DTE) An enddevice which sends/receives data to/from a DCE, often providing a user-interface for information exchange. Common examples are computers, terminals, and printers. dBm Stands for “Decibels referenced to one milliwatt (1 mW)”. A standard unit of power level commonly used in RF and communications (n/10) work. n dBm is equal to 10 milliwatt, so 0dBm = 1mW, -10dBm = 0.1mW, -20dBm = 0.01mW, etc. DCE See Data Communications Equipment. DTE See Data Terminal Equipment. Flow Control A method of moderating the transmission of data so that all devices within the communications link (DTEs and DCEs) transmit and receive only as much data as they can handle at once. This prevents devices from sending data which cannot be received at the other end due to conditions such as a full buffer or hardware not in a ready state. This is ideally handled by hardware using flow-control and handshaking signals, but 41 can be controlled also by software using X-ON/XOFF (transmitter on/off) commands. Frequency-hopping A type of spread spectrum communication whereby the carrier frequency used between transmitter and receiver changes repeatedly in a synchronized fashion according to a specified algorithm or table. This minimizes unauthorized jamming (interference) and interception of telecommunications. Full-duplex Where data can be transmitted, simultaneously and independently, bidirectionally. Half duplex Exists when the communications medium supports bi-directional transmission, but data can only travel in one direction at the same time. Handshaking A flow-control procedure for establishing data communications whereby devices indicate that data is to be sent and await appropriate signals that allow them to proceed. Line-of-sight Condition in which a transmitted signal can reach its destination by travelling a straight path, without being absorbed and/or bounced by objects in its path. Master The station which controls and/or polls one or more Slave stations in a point-to-point or pointto-multipoint network. Often functions as a server or hub for the network. Non-volatile memory Memory which retains information which is written to it. Null modem cable See Crossover cable. Point-to-point A simple communications network in which only two DTEs are participants. Point-to-multipoint A communications network in which a Master DTE communicates with two or more Slave DTEs. Repeater A device which automatically amplifies or restores signals to compensate for distortion and/or attenuation prior to retransmission. A repeater is typically used to extend the distance for which data can be reliably transmitted using a particular medium or communications device. many newer devices use a compact 9-pin connector with only the essential signaling lines used in asynchronous serial communications. Lines have two possible states: “high” (on, active, asserted, carrying +3 to +25 V) or “low” (off, inactive, disasserted, carrying -3 to -25 V). RTU (Remote Terminal Unit) A common term describing a DTE device which is part of a widearea network. Often a RTU performs data I/O and transmits the data to a centralized station. Serial communications A common mode of data transmission whereby character bits are sent sequentially, one at a time, using the same signaling line. Contrast with parallel communications where all bits of a byte are transmitted at once, usually requiring a signal line for each bit. Shielded cable Interface medium which is internally shrouded by a protective sheath to minimize external electromagnetic interference (“noise”). Slave A station which is controlled and/or polled by the Master station for communications. Typically represents one end of a point-to-point connection, or one of the terminal nodes in a point-tomultipoint network. Often a RTU is linked by a Slave DCE. Spread spectrum A method of transmitting a signal over a wider bandwidth (using several frequencies) than the minimum necessary for the originally narrowband signal. A number of techniques are used to achieve spread spectrum telecommunications, including frequency hopping. Spread spectrum provides the possibility of sharing the same band amongst many users while increasing the tolerance to interference and noise, and enhancing privacy of communications. Throughput A measure of the rate of data trans- mission passing through a data communication system, often expressed as bits or characters per second (bps or cps). RS-232 (Recommended Standard 232; more accurately, RS-232C or EIA/TIA-232E) Defined by the EIA, a widely known standard electrical and physical interface for linking DCEs and DTEs for serial data communications. Traditionally specifies a 25-pin D-sub connector, although 42 MHX-2400 Operating Manual: Appendix H . Glossary
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 46 Creator : Microsoft Word Create Date : 2000:12:01 10:38:48 Title : MHX2400MANUA… Author : Licensed User Producer : Acrobat PDFWriter 4.0 for WindowsEXIF Metadata provided by EXIF.tools